首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A highly sensitive high-performance liquid chromatographic method with fluorescence detection has been developed and validated in a single laboratory for the trace determination of trimetazidine (TMZ) in human plasma. Fluoxetine (FLX) was used as the internal standard. TMZ and FLX were isolated from plasma by protein precipitation with acetonitrile and derivatized by heating with 7-chloro-4-nitrobenzo-2-oxa-1,3-diazole in pH 8 borate buffer at 70 degrees C for 30 min. Separations were performed in the isocratic mode on a Nucleosil CN column with the mobile phase acetonitrile-10 mM sodium acetate buffer (pH 3.5)-methanol (47 + 47 + 6, v/v/v) at a flow rate of 1.0 mL/min. The derivatized samples were excited at 470 nm and monitored at an emission wavelength of 530 nm. Under the optimum chromatographic conditions, a linear relationship with a good correlation coefficient (r = 0.9997, n = 5) was obtained for the peak area ratio of TMZ to FLX and for TMZ concentrations of 1-120 ng/mL. The proposed method has the lowest limits of detection and quantitation reported to date for the determination of TMZ in plasma with values of 0.3 and 0.95 ng/mL, respectively. The values for intra- and interassay precision were satisfactory; the relative standard deviations were < or =4.04%. The accuracy of the method was demonstrated; the recoveries of TMZ from spiked human plasma were 98.13-102.83 +/- 0.2-4.04%. The method has high throughput because of its simple sample preparation procedure and short run time (<10 min). The results demonstrated that the proposed method would have great value when applied in pharmacokinetic studies for TMZ.  相似文献   

2.
A sensitive, simple and reliable method using high-performance liquid chromatographic (HPLC) assay of fluvoxamine (FLU), a selective serotonin reuptake inhibitor (SSRI), in rat plasma after pre-column derivatization with 4-fluoro-7-nitro-2,1,3-benzoxadiazole (NBD-F) was developed in this study. Extracted plasma samples were mixed with NBD-F at 60 degrees C for 5 min and injected into HPLC. Retention times of FLU and an internal standard (propafenone) derivative were 15.5 and 13.5 min, respectively. The calibration curve was linear over the range 0.015-1.5 microg/mL (r2 = 0.9985) and the lower limits of detection and quantification of FLU were 0.008 and 0.015 microg/mL, respectively, in 100 microL of plasma. The derivative sample was stable at 4 degrees C for 1 day. The coefficients of variation for intra-day and inter-day assay of FLU were less than 8.3 and 9.6%, respectively. Other SSRIs and centrally acting drugs did not interfere with the peak of the FLU derivative. The method was applied for analysis of the plasma samples from rats treated with FLU. These results indicate that the method presented is useful to determine the FLU levels in rat plasma of volumes as small as 100 microL and can be applied to pharmacokinetic studies.  相似文献   

3.
Phenoprolamine hydrochloride is a novel compound that works against a variety of types of hypertension. The purpose of this study was to develop a simple and sensitive high-performance liquid chromatographic method for quantitation of low phenoprolamine hydrochloride concentrations in human plasma and to apply it to pharmacokinetic study. The procedure involved extraction of the drug and clonidine (internal standard) from the plasma using diethyl ether. Chromatographic separations were carried out on a 4.6 x 200 mm Hypersil silica column with UV detection at 230 nm. The isocratic mobile phase, 1% ammonium acetate (pH 5.4) and methanol (0.3:99.7, v/v), was run at 1 mL/min. Extraction recovery was 84% for phenoprolamine hydrochloride at a concentration level of 200 ng/mL, and 76% for clonidine at 200 ng/mL. The method was linear in the concentration range 5-4000 ng/mL with a lower limit of quantitation of 5 ng/mL for phenoprolamine hydrochloride. Inter- and intra-day coefficients of variation were less than 10%. The validated method was successfully applied to a pharmacokinetic study in human after an oral administration of the drug, and the pharmacokinetic parameters are presented.  相似文献   

4.
A high-performance liquid chromatographic method has been developed for the determination of pipotiazine in human plasma and urine. After selective extraction, pipotiazine and the internal standard (7-methoxypipotiazine) and chromatographed on a column packed with Spherosil XOA 600 (5 micrometers) using a 7:3 (v/v) mixture of diisopropyl either--isooctane (1:1, v/v + 0.2% triethylamine and diisopropyl ether--methanol (1:1, v/v) + 0.2% triethylamine + 2.6% water. The eluted compounds are measured by fluorescence detection. The sensitivity of the method was established at 0.25 ng/ml pipotiazine in plasma and 2 ng/ml pipotiazine in urine (C.V. less than 5%). The method has been successfully applied to a pharmacokinetic study following a single oral administration of 10 mg of pipotiazine.  相似文献   

5.
A sensitive high-performance liquid chromatographic method with fluorescence detection was developed to determine memantine (MT) in rat plasma. The method consists of pre-column labeling of MT with 4-(4,5-diphenyl-1H-imidazol-2-yl)benzoyl chloride (DIB-Cl) and a clean-up step with solid-phase extraction. A good separation of DIB-MT was achieved within 12 min on an octadecylsilica (ODS) column (150 × 4.6 mm i.d.; 5 μm) with a mobile phase of acetonitrile-water (70:30, v/v). The calibration curve prepared with fluoxetine as an internal standard showed good linearity in the range of 10-400 ng/mL (r = .999). The limits of detection and quantitation at signal-to-noise ratios of 3 and 10 were 2.0 and 6.6 ng/mL, respectively. The method was shown to be reliable with precisions of <5% for intra-day and <9% for inter-day as relative standard deviation. The fluorescence property and reaction yield of authentic DIB-MT were also examined. The proposed method was successfully applied to study the pharmacokinetic interaction between MT and methazolamide.  相似文献   

6.
A simple, sensitive, selective and reliable reversed-phase high-performance liquid chromatographic (HPLC) method with UV detection is described for the determination of naltrexone in plasma samples. Naltrexone and the internal standard, naloxone, were isolated from plasma either with a liquid-liquid extraction method using ethyl acetate or with a solid-phase extraction method using Sep-Pack C18 cartridge before chromatography. The extracts were dried under a stream of nitrogen and the samples were reconstituted in the mobile phase, then 20 microL were injected on a Waters Symmetry C18 column (5 microm particle size, 4.6 x 150 mm). The mobile phase consisted of 0.06% triethylamine (pH 2.8)-acetonitrile (92:8, v/v) pumped at 1 mL/min. The peak-area ratio versus plasma concentration was linear over the range of 10-500 ng/mL and the detection limit was less than 8 ng/mL. Quantification was by ultra-violet detection at 204 nm. The present method was applied to the determination of the plasma concentration of naltrexone in dialyzed patients. Patients (n = 8) with severe generalized pruritus received 50 mg of naltrexone orally per day for 2 weeks. The variability in the therapeutic response in treated patients required plasma concentration investigations of this opioid antagonist.  相似文献   

7.
Nifedipine (Nif) is widely used in treating cardiovascular disorders (especially hypertension) and for inhibiting preterm labor. A fully validated selective high-performance liquid chromatographic method with diode array detection, using solid-phase extraction, was developed for the determination of Nif in human serum. To assess specificity, Nif and its degradation products were separated on a Purospher RP-18 (5 microm, 125 x 4 mm) column plus a LiChrospher 100 RP-18 (5 microm, 4 x 4 mm) precolumn with a mobile phase of methanol-10 mM aqueous trifluoroacetic acid, pH 7.3 (57 + 43, v/v); chromatographic separation was followed by UV detection at 238 nm. For toxicological analysis, Nif in the presence of other calcium-channel antagonist drugs was identified under optimum chromatographic conditions. The calibration graph was constructed over the concentration range of 12.5-400 ng/mL in serum with good correlation (r = 0.9956). This method was not subject to interference by other plasma components and was successfully applied to the assay of Nif in spiked human serum and in serum of women in preterm labor after sublingual administration of 30 mg Nif per day divided into 3 equal doses. The mean recovery based on the ratio of the slopes of serum and mobile phase standard curves was 96.5%. The detection and quantification limits of the drug in spiked human serum were found to be 6 and 17.5 ng/mL, respectively. Validation of the method demonstrated good intraday and interday precision, which ranged from 2.18 to 6.67% and from 6.52 to 11.93%, respectively.  相似文献   

8.
A high-performance liquid chromatographic (HPLC) method for the analysis of coenzyme Q10 (CoQ10) in human seminal plasma was developed and applied to investigate its clinical significance as a reference index relating to oxidative stress and infertile status of spermatozoa. After precipitation of proteins in seminal plasma with methanol, CoQ10 and coenzyme Q9 (CoQ9; internal standard) were extracted with hexane. The supernatant after centrifugation was evaporated to dryness with nitrogen at 45 degrees C. The residue was re-dissolved in isopropanol. HPLC separation of the sample solution was performed on a Lichrospher C(18) column with a mobile phase composed of isopropanol-methanol-tetrahydrofuran in the ratio of 55:39:6 (v/v/v) at a flow rate of 1.0 mL/min. Under the chromatographic conditions described, the CoQ10 and CoQ9 had retention times of approximately 5.83 and 4.97 min, respectively. The peaks were detected at UV 275 nm. Good separation and detectability of CoQ10 in human seminal plasma were obtained. The method was linear in the range 0.01-10.00 microg/mL. The relative standard deviations within- and between-assay for CoQ10 analysis were 0.85 and 1.86%, respectively. The average recoveries were 94.1-99.0% for the human seminal plasma samples. The CoQ10 levels in seminal plasma of 195 patients and 23 control subjects were studied. CoQ10 concentrations in the two populations were: 37.1 +/- 12.2 ng/mL in the fertile group and 48.5 +/- 20.4 ng/mL in the infertile group. The large difference (p < 0.01) between the fertile and infertile populations is evident.  相似文献   

9.
Zafirlukast (ZAF) is a leukotriene receptor antagonist used in the treatment of chronic asthma. In this study, a simple and sensitive reversed-phase, high-performance liquid chromatographic method was developed for the determination of ZAF in pharmaceutical formulations and human plasma. Piribedil was used as an internal standard. Analysis was carried out on a Nucleosil C18 100 A (150 mm x 4.6 mm id, 5 Vm) column with acetonitrile-pH 3.0 acetate buffer (70 + 30, v/v) as the mobile phase at a flow rate of 0.8 mL/min. The peak was detected by an ultraviolet detector set at a wavelength of 240 nm. The retention times were about 3.9 min for piribedil and 5.8 min for ZAF. The developed method was applied to the determination of ZAF in its pharmaceutical formulation and spiked human plasma. For quantification of ZAF in spiked plasma, proteins were precipitated with ethanol before chromatographic analysis. The calibration range was linear from 49.69-437.50 ng/mL in spiked plasma. The absolute recovery from spiked plasma was 98.73 +/- 0.42% at a concentration of 254.78 ng/mL of ZAF. No endogenous substances from plasma were found to interfere.  相似文献   

10.
A high-performance liquid chromatographic method with UV detection has been developed for the determination of saikosaponin a in rat plasma. Saikosaponin a and internal standard jujuboside A were isolated from plasma samples by solid-phase extraction. The chromatographic separation was achieved on a reversed-phase C(18) column with the mobile phase of acetonitrile-water (35:65, v/v) at a flow rate of 1 mL/min and UV detection was set at 205 nm. The standard curve for saikosaponin a was linear over the concentration range 0.25-10 microg/mL and the limit of detection was 0.05 microg/mL. The absolute recovery was greater than 82%. The precision and accuracy ranged from 3.05 to 9.59% and 95.61 to 110.00%, respectively. The validated method was used to determine saikosaponin a in plasma samples in a pharmacokinetic study of saikosaponin a administered to Sprague-Dawley rats.  相似文献   

11.
A rapid, precise, accurate, and selective high-performance liquid chromatographic method with fluorescence detection has been validated and used for analysis of amisulpride in human plasma after a simple solid-phase extraction procedure. Compounds were separated on a CN column with 0.03?M potassium dihydrogen phosphate (pH 6.5)-acetonitrile 65:35 (v/v) as mobile phase. Fluorescence detection was performed at excitation and emission wavelengths of 274 and 370?nm, respectively. Calibration plots were linear over the concentration range 10-1,000?ng?mL(-1) in human plasma, and the lower limit of quantification was 10?ng?mL(-1). Accuracy was between 0.4 and 6.4% and precision was between 3.1 and 7.5%. Amisulpride was sufficiently stable through three freeze-thaw cycles, during storage for 6?h at room temperature, and for 2?months at -22?°C. The method is suitable for the analysis of clinical samples from pharmacokinetic studies.  相似文献   

12.
A simple high-performance liquid chromatographic method with ultraviolet detection is proposed for the estimation of diclofenac potassium and drotaverine hydrochloride in human plasma. Liquid-liquid extraction was carried out with a mixture of dichloromethane-isopropyl alcohol (80:20, v/v). Chromatographic separation of the analytes and internal standard was achieved on an analytical 250 × 4.6 mm i.d. reversed-phase Thermo BDS Hypersil C8 (5 μm particle size) column using a mobile phase of acetonitrile-0.02M ammonium acetate buffer (53:47, v/v) at pH 3.5. The run time was less than 15 min. Column eluate was monitored at 230 nm. The linearity over the concentration ranges of 25-1500 ng/mL and 32-960 ng/mL was obtained for diclofenac potassium and drotaverine hydrochloride, respectively. The limit of quantification was 25 and 32 ng/mL for diclofenac potassium and drotaverine hydrochloride, respectively. Recoveries of diclofenac potassium and drotaverine hydrochloride from plasma were 97.45% and 98.27%, respectively.  相似文献   

13.
A reversed-phase high-performance liquid chromatographic (HPLC) method for the simultaneous determination of clozapine and its two major metabolites, norclozapine and clozapine-N-oxide in human plasma has been developed and validated. The isocratic HPLC assay uses a mobile phase consisting of an acetonitril-buffered aqueous solution containing 146 microL of triethylamine and 200 microL of 85% phosphoric acid, adjusted to pH 3.3 with 10% potassiumhydroxide solution (400:600, v/v) at a flow-rate of 0.8 ml/min and a Lichrospher 100 RP-18 reversed-phase column and UV detection at 215 nm. Doxepine was used as the internal standard. Mean recoveries for clozapine, norclozapine, clozapine-N-oxide and doxepine were 95%, 98%, 96% and 94%, respectively, whereas the respective mean repeatability coefficients of variation were 3.4%, 2.7%, 4.3% and 0.9%. Reproducibility coefficients of variation were 1.3%, 1.8%, 3.6% and 0.5%, respectively. The mean correlation coefficient for the linear calibration curve (n = 2) for clozapine and norclozapine at a concentration range of 100-1600 ng/mL was 0.9998 and 0.9997, respectively; for clozapine-N-oxide (20-200 ng/mL) it was found to be 0.9986. The lower limits of quantitation were 12.5 ng/mL, 10 ng/mL and 12.5 ng/mL for clozapine, norclozapine and clozapine-N-oxide, respectively.  相似文献   

14.
A simple, selective and sensitive procedure is described for the quantitation of flupirtine maleate (FLU) and its active acetylated metabolite (Met. 1) in plasma and urine. Using a 0.5-ml sample, a sensitivity of 10 ng/ml is easily achieved with a reversed-phase octadecylsilane (C18) column, and a high-performance liquid chromatographic system with fluorescence detection. Quantitation from plasma involves addition of an internal standard, protein precipitation with acetonitrile and a sample concentrating step, while for urinalysis the samples are taken through a single extraction with methylene chloride. Analytical recoveries of FLU and Met. 1 from plasma averaged greater than or equal to 95%, while from urine only 60 and 50%, respectively, could be recovered. The overall, inter- and intra-day variability for both FLU and Met. 1 averaged 6, 5 and 3%, in plasma, respectively. Standard calibration plots in plasma were linear (r greater than or equal to 0.99) for FLU (range: 0.01-10.0 micrograms/ml) and Met. 1 (range: 0.5-25 micrograms/ml) over the extended range. A slightly modified elution system was employed for quantitation of FLU and Met. 1 in urine.  相似文献   

15.
A simple high-performance liquid chromatographic method for the determination of doxazosin in human plasma was developed and validated. Prazosin was used as internal standard. After extraction twice with ethyl acetate, chromatographic separation of doxazosin in human plasma was carried out using a reversed-phase Apollo C18 column (250 x 4.6 mm, 5 microm) with mobile phase of methanol-acetonitrile-0.04 m disodium hydrogen orthophosphate (22:22:56, v/v/v) adjusted to pH 4.9 with 0.9 m phosphoric acid and quantified by fluorescence detection operated with an excitation wavelength of 246 nm and an emission wavelength of 389 nm. The lower limit of quantification (LLOQ) of this assay was 1 ng/mL using 500 microL human plasma. Linearity was established over the range 1-25 ng/mL (r2 > 0.9994). The intra- and inter-day accuracy ranged from 90.5 to 104.4% and the coefficient of variation were not more than 8.6% for both intra- and inter-day precision, over the range of the calibration curve. The absolute recoveries of doxazosin and prazosin from human plasma were more than 91%. Doxazosin demonstrated acceptable short-term, long-term and freeze-thaw stability in human plasma. The assay has been successfully applied to plasma sample ana-lysis for pharmacokinetic study.  相似文献   

16.
A highly sensitive high-performance liquid chromatographic quantification method with fluorescence detection was developed and validated for the determination of doxazosin in human plasma. The developed method employed one-step extraction of doxazosin from plasma matrix with ethyl acetate using propranolol as an internal standard. Chromatographic separation was obtained within 8.0 min using a reverse-phase Capcell-Pak C(18) column (150 x 4.6 mm i.d., 5 microm) and the mobile phase consisted of methanol-water containing 10 mM perchloric acid and 1.8 mM sodium heptane sulfonic acid (50:50, v/v) and was set at a flow rate of 1.5 mL/min. The calibration curve constructed was linear in the range of 0.3-50.0 ng/mL. The proposed method achieved a lower limit of quantification of 0.3 ng/mL, better than the reported HPLC methods. Average recoveries of doxazosin and the internal standard from human plasma matrix were 87.0 and 85.9%, respectively. The present method was validated by evaluating the precision and accuracy for inter- and intraday variation in the concentration range 0.3-50 ng/mL. The precision values expressed as relative standard deviations in the inter- and intraday validation were 1.17-6.29 and 0.84-5.94%, respectively. This method was successfully applied to the bioequivalence study of two doxazosin controlled release tablets in healthy, male human subjects.  相似文献   

17.
An isocratic high-performance liquid chromatographic method for determination of triptolide and triptonide in human plasma is described. Plasma samples were extracted with OasisHLB solid-phase extraction (SPE) cartridges. After pretreatment, they were separated on a SymmetryShieldRP(18) column with a mobile phase of acetonitrile-water (40:60,v/v) at 40 degrees C. The effluent was monitored at UV 217 nm. Linearity (0.010-1.0 mg/L) was good, and the lower limit of detection was 3 ng/mL for triptolide and 4.5 ng/mL for triptonide (S/N = 3). The relative standard deviations of intra- and inter-day assay were less than 15% and the recoveries were better than 80%. The developed method was applied to the determination of triptolide and triptonide concentration in a patient's plasma after taking the medicament containing Tripterygium wilfordii Hook. F.  相似文献   

18.
A method is described for the simultaneous determination of paracetamol, tizanidine, and diclofenac in mixtures. The method was based on HPLC separation of the three drugs followed by UV detection at 254 nm. The separation was carried out on a Hypersil ODS, C18 (250 x 4.6 mm id, 10 microm particle size) column using the mobile phase aqueous 0.2% ammonium carbonate-methanol (60 + 40, v/v) at a flow rate of 1 mL/min. The linear regression analysis data were used for the regression curve in the range of 170-10 000 ng/mL for paracetamol, 120-10 000 ng/mL for tizanidine, and 20-10 000 ng/mL for diclofenac. No chromatographic interference from tablet excipients was found. In order to check the selectivity of the proposed method, degradation studies were carried out using hydrolysis (acid, basic, and neutral), thermolysis, and oxidation. The developed method, after being validated in terms of precision, robustness, recovery, LOD, and LOQ, was successively applied to the analysis of pharmaceutical formulations and human serum.  相似文献   

19.
The development and validation of an LC-MS/MS method for the simultaneous determination of albendazole metabolites (albendazole sulfoxide and albendazole sulfone) in human plasma are described. Samples of 200 μL were extracted with ether-dichloromethane-chloroform (60:30:10, v/v/v). The chromatographic separation was performed using a C(18) column with methanol-formic acid 20 mmol/L (70:30) as the mobile phase. The method was linear in a range of 20-5000 ng/mL for albendazole sulfoxide and 10-1500 ng/mL for albendazole sulfone. For both analytes the method was precise (RSD < 12%) and accurate (RE <7%) with high recovery (>90%). The method was successfully applied to determine the plasma and cerebrospinal fluid levels of albendazole sulfoxide and albendazole sulfone in patients with subarachnoidal neurocysticercosis who received albendazole at 30 mg/kg per day for 7 days. This LC-MS/MS method yielded a quick, simple and reliable protocol for determining albendazole sulfoxide and albendazole sulfone concentrations in plasma and cerebrospinal fluid samples and is applicable to therapeutic monitoring.  相似文献   

20.
A simple and sensitive reversed-phase high performance liquid chromatographic method (HPLC) has been developed and validated for the routine analysis of diltiazem in human plasma and the study of the pharmacokinetics of the drug in the human body. Diltiazem and diazepa (internal standard) were extracted with a mixed organic solution of hexane, chloroform and isopropanol (60:40:5, v/v/v), and then HPLC separation of the drugs was performed on an Spherisorb C(18) column and detected by ultraviolet absorbance at 239 nm. The use of methanol-water solution (containing 2.8 mm triethylamine, 80:20, v/v) as the mobile phase at a fl ow-rate of 1.2 mL/min enables the baseline separation of the drugs free from interferences with isocratic elution. The method was linear in the clinical range 0-300 ng/mL and the lower limit of detection of diltiazem in plasma was 3 ng/mL. The range of percentage of relative standard deviation (%RSD) was from 3.5 to 6.8% for within-day analyses and from 6.2 to 8.4% for between-day analyses, respectively. The extraction recoveries of diltiazem from spiked human plasma (n = 5) at three concentrations were 91.4-104.0%. The method has been used to determine diltiazem in human plasma samples from eight volunteers who had taken diltiazem hydrochloride slow release tables and the data obtained was fitted with a program on computer to study the pharmacokinetics. The results showed that the peak level in plasma approximately averaged 118.5 +/- 14.3 ng/mL at 3.1 +/- 0.4 h, and the areas under the drug concentration curves (AUC) was 793.1 +/- 83.1 ng.h/mL.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号