首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A method for simultaneous determination of seven benzodiazepines (BZPs) (flunitrazepam, clonazepam, oxazepam, lorazepam, chlordiazepoxide, nordiazepam and diazepam using N-desalkylflurazepam as internal standard) in human plasma using liquid-liquid and solid-phase extractions followed by high-performance liquid chromatography (HPLC) is described. The analytes were separated employing a LC-18 DB column (250 mm × 4.6 mm, 5 μm) at 35 °C under isocratic conditions using 5 mM KH2PO4 buffer solution pH 6.0:methanol:diethyl ether (55:40:5, v/v/v) as mobile phase at a flow rate of 0.8 mL min−1. UV detection was carried out at 245 nm. Employing LLE, the best conditions were achieved with double extraction of 0.5 mL plasma using ethyl acetate and Na2HPO4 pH 9.5 for pH adjusting. Employing SPE, the best conditions were achieved with 0.5 mL plasma plus 3 mL 0.1 M borate buffer pH 9.5, which were then passed through a C18 cartridge previously conditioned, washed for 3 times with these solvents: 3 mL 0.1 M borate buffer pH 9.5, 4 mL Milli-Q water and 1 mL acetonitrile 5%, finally the BZPs elution was carried with diethyl ether:n-hexane:methanol (50:30:20). In both methods the solvent was evaporated at 40 °C under nitrogen flow. The validation parameters obtained in LLE were linearity range of 50-1200 ng mL−1 plasma (r ≥ 0.9927), limits of quantification of 50 ng mL−1 plasma, within-day and between-day CV% and E% for precision and accuracy lower than 15%, and recovery above 65% for all BZPs. In SPE, the parameter obtained were linearity range of 30-1200 ng mL−1 plasma (r ≥ 0.9900), limits of quantification of 30 ng mL−1 plasma, within-day and between-day CV% and E% for precision and accuracy lower than 15% and recovery above 55% for all BZPs. These extracting procedures followed by HPLC analysis showed their suitable applicability in order to examine one or more BZPs in human plasma. Moreover, it could be suggested that these procedures might be employed in various analytical applications, in special for toxicological/forensic analysis.  相似文献   

2.
A three-phase liquid-phase microextraction (LPME) method using porous polypropylene hollow fibre membrane with a sealed end was developed for the extraction of mirtazapine (MRT) and its two major metabolites, 8-hydroxymirtazapine (8-OHM) and demethylmirtazapine (DMR), from human plasma. The analytes were extracted from 1.0 mL of plasma, previously diluted and alkalinized with 3.0 mL 0.5 mol L−1 pH 8 phosphate buffer solution and supplemented with 15% sodium chloride (NaCl), using n-hexyl ether as organic solvent and 0.01 moL L−1 acetic acid solution as the acceptor phase. Haloperidol was used as internal standard. The chromatographic analyses were carried out on a chiral column, using acetonitrile-methanol-ethanol (98:1:1, v/v/v) plus 0.2% diethylamine as mobile phase, at a flow rate of 1.0 mL min−1. Multi-reaction monitoring (MRM) detection was performed by mass spectrometry (MS-MS) using a triple-stage quadrupole and electrospray ionization interface operating in the positive ion mode. The mean recoveries were in 18.3-45.5% range with linear responses over the 1.25-125 ng mL−1 concentration range for all enantiomers evaluated. The quantification limit (LOQ) was 1.25 ng mL−1. Within-day and between-day assay precision and accuracy (2.5, 50 and 100 ng mL−1) showed relative standard deviation and the relative error lower than 11.9% for all enantiomers evaluated. Finally, the method was successfully used for the determination of mirtazapine and its metabolite enantiomers in plasma samples obtained after single drug administration of mirtazapine to a healthy volunteer.  相似文献   

3.
Fong BM  Tam S  Tsui SH  Leung KS 《Talanta》2011,83(3):1030-1036
A sensitive analytical method for the determination of tetrodotoxin (TTX) in urine and plasma matrices was developed using double solid phase extraction (C18 and hydrophilic interaction liquid chromatography) and subsequent analysis by HPLC coupled with tandem mass spectrometry. The double SPE sample cleanup efficiently reduced matrix and ion suppression effects. Together with the use of ion pair reagent in the mobile phase, isocratic elution became possible which enabled a shorter analysis time of 5.5 min per sample. The assay results were linear up to 500 ng mL−1 for urine and 20 ng mL−1 for plasma. The limit of detection and limit of quantification were 0.13 ng mL−1 and 2.5 ng mL−1, respectively, for both biological matrices. Recoveries were in the range of 75-81%. To eliminate the effect of dehydration and variations in urinary output, urinary creatinine-adjustment was made. TTX was quantified in eight urine samples and seven plasma samples from eight patients suspected of having TTX poisoning. TTX was detected in all urine samples, with concentrations ranging from 17.6 to 460.5 ng mL−1, but was not detected in any of the plasma samples. The creatinine-adjusted TTX concentration in urine (ranging from 7.4 to 41.1 ng μmol−1 creatinine) correlated well with the degree of poisoning as observed from clinical symptoms.  相似文献   

4.
Al-Hadiya BM  Khady AA  Mostafa GA 《Talanta》2010,83(1):110-116
A highly selective, sensitive and rapid high performance liquid chromatographic method has been developed and validated to quantify gemifloxacin in human plasma. The gemifloxacin and internal standard (ciprofloxacin) were extracted by ultrafiltration technique followed by injection into chromatographic system. Chromatographic separation was achieved on a reversed phase C18 column with a mobile phase of acetonitrile:0.1% trifluoroacetic acid (20:80, v/v) using isocratic elution (at flow rate 1 mL min−1). The analytes were detected at 269 and 393 nm for excitation and emission, respectively. The assay exhibited a linear range of 25-5000 ng mL−1 for gemifloxacin in human plasma. The lower limit of detection was 10 ng mL−1. The method was statistically validated for linearity, accuracy, precision and selectivity following FDA guidelines. The intra- and inter-assay coefficients of variation did not exceed 7.6% deviation of the nominal concentration. The recovery of gemifloxacin from plasma was greater than 97.0%. Stability of gemifloxacin in plasma was excellent with no evidence of degradation during sample processing (auto-sampler) and at least 3 months storage in a freezer at −70 °C. This validation method is applied for clinical study of the gemifloxacin in human volunteers.  相似文献   

5.
A novel immunoassay format employing direct coating of small molecular hapten on microtiter plates is reported for the detection of atrazine and 2,4-dichlorophenoxyacetic (2,4-D). In this assay, the polystyrene surface of microtiter plates was first treated with an acid to generate -NO2 groups on the surface. Acid treated plates were further treated with 3-aminoprpyltriethoxysilane (APTES) to functionalize the plate surface with amino groups for covalent linkage to small molecular hapten with carboxyl groups. The modified plates showed significantly high antibody binding in comparison to plates coated with hapten-carrier protein conjugates and presented excellent stability as a function of the buffer pH and reaction time. The developed assay employing direct hapten coated plates and using affinity purified atrazine and 2,4-D antibodies demonstrated very high sensitivity, IC50 values for atrazine and 2,4-D equal to 0.8 ng mL−1 and 7 ng mL−1, respectively. The assay could detect atrazine and 2,4-D levels in standard water samples even at a very low concentration upto 0.02 and 0.7 ng mL−1 respectively in the optimum working range between 0.01 and 1000 ng mL−1 with good signal reproducibility (p values: 0.091 and 0.224 for atrazine and 2,4-D, respectively). The developed immunoassay format could be used as convenient quantitative tool for the sensitive screening of pesticides in samples.  相似文献   

6.
Aboul-Enein HY  Ali I 《Talanta》2005,65(1):276-280
The simple, reliable and reproducible HPLC and extraction methods were developed for the analysis of tadalafil in pharmaceutical preparation. The column used was monolithic silica column, Chromolith Performance RP-18e (100 mm × 4.6 mm, i.d.). The mobile phase used was phosphate buffer (100 mM, pH 3.0)-acetonitrile (80:20, v/v) at the flow rate of 5 mL min−1 with UV detection at 230 nm at ambient temperature. Extraction of tadalafil from tablet was carried out using methanol. Linearity was observed in the concentration range from 100 to 5000 ng mL−1 for tadalafil with a correlation coefficient (R2) 0.9999 and 100 ng mL−1 as the limit of detection. The values of linearity range, correlation coefficient (R2) and limit of detection were 50-5000 ng mL−1, 0.9999-50 ng mL−1, respectively for sildenafil. Parameters of validation prove the precision of the method and its applicability for the determination of tadalafil in pharmaceutical tablet formulation. The method is suitable for high throughput analysis of the drug.  相似文献   

7.
A novel flow-injection spectrophotometry has been developed for the determination of molybdenum(VI) at nanograms per milliliter levels. The method is based on the catalytic effect of molybdenum(VI) on the bromate oxidative coupling of p-hydrazinobenzenesulfonic acid with N-(1-naphthyl)ethylenediamine to form an azo dye (λmax = 530 nm). Chromotropic acid (4,5-dihydroxy-2,7-naphthalenedisulfonic acid) acted as an effective activator for the molybdenum(VI)-catalyzed reaction and increased the sensitivity of the method. The reaction was monitored by measuring the change in absorbance of the dye produced. The proposed method allowed the determination of molybdenum(VI) in the range 1.0-20 ng mL−1 with sample throughput of 15 h−1. The limit of detection was 0.5 ng mL−1 and a relative standard deviation for 10 ng mL−1 molybdenum(VI) (n = 10) was 2.5%. The interfering ions were eliminated by using the combination of a masking agent and on-line minicolumn packed with cation exchanger. The present method was successfully applied to the determination of molybdenum(VI) in plant foodstuffs.  相似文献   

8.
Zhuo SJ  Zheng H  Chen JL  Li DH  Wu YQ  Zhu CQ 《Talanta》2004,64(2):528-533
A new method was developed for determination of micro amounts of nucleic acids based on near-infrared (near-IR) fluorescence recovery, employing a two-reagent system which is composed of an anionic tetracarboxy aluminum phthalocyanine (AlC4Pc) and a cationic tetra-N-hexadecylpyridiniumyl porphyrin (TC16PyP). The fluorescence of the AlC4Pc, with the maximum emission wavelength at 701 nm, could be quenched by TC16PyP at its proper concentration, but recovered by adding nucleic acids. Under optimal conditions, the recovered fluorescence is proportional to the concentration of nucleic acids. The calibration graphs are linear over the range of 1-200 ng mL−1 for fish sperm DNA (FS DNA) and 2-400 ng mL−1 for calf thymus DNA (CT DNA). The corresponding detection limits are 0.59 ng mL−1 for FS DNA and 0.82 ng mL−1 for CT DNA, respectively. Four synthetic and three real nucleic acid samples were determined with satisfactory results.  相似文献   

9.
A simple, sensitive and accurate reverse phase high-performance liquid chromatographic (RP-HPLC) method with photo-diode array detector (PDA) was developed and validated for the determination of amphotericin B (AMB) in the rat plasma using a new internal standard (IS) α-naphthol. The plasma samples were subjected to protein precipitation with methanol prior to a HPLC analysis. Chromatographic separations were achieved on a Nucleosil® 100-5C18 (150 mm × 4.6 mm) column. The mobile phase consisted of acetonitrile and sodium acetate buffer (pH 4; 10 mM) in a gradient mode. Detection was carried out at a wavelength of 407 and 294 nm for AMB and IS, respectively. The retention times of AMB and IS were about 6.8 and 7.8 min, respectively. The calibration curve was linear in the range of 10-2000 ng mL−1 for AMB (r2 > 0.998). No significant matrix effect was observed on quantification of AMB or IS. At three quality control concentrations of 20, 500, and 2000 ng mL−1, the intra-day and inter-day relative standard deviation ranged from 1.13% to 4.91%. The limit of detection (LOD) was 5 ng mL−1 and the limit of quantification (LOQ) was 10 ng mL−1 for AMB in rat plasma. This method is simple, sensitive, rapid and does not require any extensive sample purification before injecting into HPLC.  相似文献   

10.
Li J  Zhao F  Ju H 《Analytica chimica acta》2006,575(1):57-61
Amitriptyline, doxepin and chlorpromazine are often used as psychotropic drugs in treatment of the various mental diseases, and are also partly excreted by kidney. This work developed a simple, selective and sensitive method for their simultaneous monitoring in human urine using capillary electrophoresis coupled with electrochemiluminescence (ECL) detection based on end-column ECL reaction of tris-(2,2′-bipyridyl)ruthenium(II) with aliphatic tertiary amino moieties. Acetone was used as an additive to the running buffer to obtain their absolute separation. Under optimized conditions the proposed method displayed a linear range from 5.0 to 800 ng mL−1 for the three drugs with the correlation coefficients more than 0.995 (n = 8). Their limits of detection were 0.8 ng mL−1 (3.6 fg), 1.0 ng mL−1 (4.5 fg) and 1.5 ng mL−1 (6.8 fg) at a signal to noise ratio of 3, respectively. The relative standard deviations for five determinations of 20 ng mL−1 amitriptyline, doxepin and chlorpromazine were 1.7%, 4.2% and 3.6%, respectively. For practical application an extract step with 90:10 heptane/ethyl acetate (v/v) was performed to eliminate the influence of ionic strength in sample. The recoveries of amitriptyline, doxepin and chlorpromazine at different levels in human urine were between 83% and 93%, which showed that the method was valuable in clinical and biochemical laboratories for monitoring amitriptyline, doxepin and chlorpromazine.  相似文献   

11.
An isocratic high-performance liquid chromatographic method has been developed for the measurement of serotonin, 5-hydroxyindolacetic and homovanillic acids in dried blood spots and in platelet poor and rich plasma samples. Analyses were carried out on a C18 reversed-phase column using a mobile phase composed of 13% methanol and 87% aqueous citrate buffer, containing octanesulfonic and ethylendiaminotetracetic acids. Coulometric detection was used, setting the guard cell at +0.100 V, the first analytical cell at −0.200 V and the second analytical cell at +0.400 V. For the pre-treatment of biological samples a novel solid-phase extraction procedure, based on mixed-mode reversed-phase – strong anion exchange Oasis cartridges, was implemented. Extraction yields of the analytes from all these matrices were satisfactory, being always higher than 89.0%. The calibration curve was linear over the on-column concentration range of 0.1–22.5 ng mL−1 for serotonin and 5-hydroxyindolacetic acid and of 0.25–22.5 ng mL−1 for homovanillic acid. The sensitivity was good with a limit of detection of 0.05 ng mL−1 for serotonin and 5-hydroxyindolacetic acid and 0.12 ng mL−1 for homovanillic acid. Results were also satisfactory in terms of precision, selectivity and accuracy. The analytical method was successfully applied to human platelet poor and rich plasma samples and to dried blood spots from volunteers and psychiatric patients.  相似文献   

12.
Kang X  Pan C  Xu Q  Yao Y  Wang Y  Qi D  Gu Z 《Analytica chimica acta》2007,587(1):75-81
A novel micro-extraction procedure was developed through the use of an electrospun polymer nanofiber as a solid-phase extraction (SPE) sorbent to directly extract trazodone from human plasma. The target compound was then monitored by a high performance liquid chromatography with ultraviolet detector (HPLC-UV) system. Parameters of influencing the extraction efficiency, such as fiber diameter, fiber packing amount, eluted solvent, pH and ionic strength were investigated. Under the optimized conditions, a linear response for trazodone over the range of 20-2000 ng mL−1 was achieved with a γ2 value of 0.9996. The precision of the method was examined with relative standard deviations of 5.7, 2.7, 2.2% corresponding to 50, 200, and 500 ng mL−1, respectively, of trazodone spiked into 0.1 mL of plasma samples. The extraction recoveries of 58.3-75.2% and the relative recoveries of 94.6-105.5% were obtained. The limit of detection (LOD) was determined to be 8 ng mL−1. A 15 min of HPLC gradient was successfully applied to determine trazodone from human plasma. Due to its simplicity, selectivity and sensitivity, the method may be applied to pharmacokinetic and pharmacodynamic studies of drugs.  相似文献   

13.
Ceren Yard?mc?  Alper Gürlek 《Talanta》2007,72(4):1416-1422
A novel, fast and simple liquid chromatographic method was developed and validated for the simultaneous determination of rosiglitazone and metformin in human plasma. The analysis was performed on a phenyl column (250 mm × 4.6 mm i.d., 5 μm) using a gradient method starting with mobile phase composed of acetonitrile:5 mM acetate buffer pH 5.5 (75:25, v/v). The flow rate was 1 mL min−1. UV detection was performed at 245 nm and verapamil was used as internal standard. The total run time was less than 10 min. Sample preparation included a simple protein precipitation step with acetonitrile. Validation experiments were performed to demonstrate stability, specificity, sensitivity, linearity, accuracy, precision and robustness. The limit of quantification was 100 ng mL−1 for rosiglitazone and 250 ng mL−1 for metformin. The extraction recoveries were 100.02-105.0% for rosiglitazone and 105.64-103.88% for metformin. The method was applied with success to plasma samples obtained from diabetic patients undergoing treatment with rosiglitazone and metformin.  相似文献   

14.
Enriching the surface density of immobilized capture antibodies enhances the detection signal of antibody sandwich microarrays. In this study, we improved the detection sensitivity of our previously developed P-Si (porous silicon) antibody microarray by optimizing concentrations of the capturing antibody. We investigated immunoassays using a P-Si microarray at three different capture antibody (PSA – prostate specific antigen) concentrations, analyzing the influence of the antibody density on the assay detection sensitivity. The LOD (limit of detection) for PSA was 2.5 ng mL−1, 80 pg mL−1, and 800 fg mL−1 when arraying the PSA antibody, H117 at the concentration 15 μg mL−1, 35 μg mL−1, and 154 μg mL−1, respectively. We further investigated PSA spiked into human female serum in the range of 800 fg mL−1 to 500 ng mL−1. The microarray showed a LOD of 800 fg mL−1 and a dynamic range of 800 fg mL−1 to 80 ng mL−1 in serum spiked samples.  相似文献   

15.
A comparison of direct immersion solid-phase microextraction (DI-SPME) and stir bar sorptive extraction (SBSE) coupled to liquid chromatography (HPLC) with fluorimetric detection for the rapid analysis of resveratrol isomers is described. For DI-SPME, a polar Carbowax-template resin (CW/TPR) 50 μm fiber was the most efficient and optimum extraction conditions were 40 °C and an extraction time of 30 min, stirring in the presence of 5% (m/v) sodium chloride and 0.07 M acetate/acetic acid buffer (pH 6). Desorption was carried out using the static mode for 10 min. Linearity was obtained in the 5-150 and 2-150 ng mL−1 ranges for trans- and cis-resveratrol, with detection limits of 2 and 0.5 ng mL−1, respectively. When using SBSE, a polydimethylsiloxane (PDMS) twister provided best extraction by means of a derivatization reaction in the presence of acetic anhydride and potassium carbonate. The same time and temperature were used for the extraction step in the presence of 2.5% (m/v) sodium chloride, and liquid desorption was performed with 150 μL of a 50/50 (v/v) acetonitrile/1% (v/v) acetic acid solution in a desorption time of 15 min. Linearity was now between 0.5 and 50 ng mL−1 for trans-resveratrol with a detection limit of 0.1 ng mL−1, while cis-resveratrol could not be extracted. The proposed methods were successfully applied to determining the resveratrol isomer content of wine, must and fruit juices.  相似文献   

16.
Orthogonal array design (OAD) was applied for the first time to optimize cloud point extraction (CPE) conditions for Se(IV) determination by electrothermal atomic absorption spectrometry (ETAAS) in environmental and biological samples. Selenium was reacted with o-phenylenediamine to form piazselenol in an acidic medium (pH 2). Using Triton X-114, as surfactant, piazselenol was quantitatively extracted into small volume (about 30 μL) of the surfactant-rich phase after centrifugation. Five relevant factors, i.e. surfactant concentration, pH, ionic strength, equilibrium time and temperature were selected and the effects of each factor were studied at four levels on the extraction efficiency of Se(IV) and optimized. The statistical analysis revealed that the most important factors contributing to the extraction efficiency are ionic strength, pH and percent of surfactant. Based on the results obtained from the analysis of variance (ANOVA), the optimum conditions for extraction were established as: pH 6; vial temperature = 50 °C; extraction time = 7 min and 0.3% (w/v) of Triton X-114. The method was permitted to obtain a detection limit of 0.09 ng mL−1 and two linear calibration ranges from 0.6 to 1.0 and 1.0 to 80.0 ng mL−1 Se. The precision (%RSD) of the extraction and determination for the six replicates of Se at 20 ng mL−1 was better than 3.6% and the enrichment factor of 63.5 was achieved. The studied analyte was successfully extracted and determined with high efficiency using cloud point extraction method in water and biological matrices.  相似文献   

17.
In this paper a novel solid phase extraction method to determine Co(II) and Ni(II) using silica gel-polyethylene glycol (Silica-PEG) as a new adsorbent is described. The method is based on the adsorption of cobalt and nickel ions in alkaline media on polyethylene glycol-silica gel in a mini-column, elution with nitric acid and determination by flame atomic absorption spectrometry. The adsorption conditions such as NaOH concentration, sample volume and amount of adsorbent were optimized in order to achieve highest sensitivity. The calibration graph was linear in the range of 0.5-200.0 ng mL−1 for Co(II) and 2.0-100.0 ng mL−1 for Ni(II) in the initial solution. The limit of detection based on 3Sb was 0.37 ng mL−1 for Co(II) and 0.71 ng mL−1 for Ni(II). The relative standard deviations (R.S.D.) for ten replicate measurements of 40 ng mL−1 of Co(II), and Ni(II) were 3.24 and 3.13%, respectively. The method was applied to determine Co(II) and Ni(II) in black tea, rice flour, sesame seeds, tap water and river water samples.  相似文献   

18.
Organophosphate triesters are common flame retardants used in a wide variety of consumer products from which they can migrate and pollute the indoor environment. Humans may thus be continuously exposed to several organophosphate triesters which might be a risk for human health. An analytical method based on direct injection of 5 μL urine into an ultra performance liquid chromatography system coupled to a time-of-flight mass spectrometry has been developed and validated to monitor exposure to organophosphate triesters through their respective dialkyl and diaryl phosphate metabolites (DAPs). The targeted analytes were: di-n-butyl phosphate (DNBP), diphenyl phosphate (DPHP), bis(2-butoxyethyl) phosphate (BBOEP), bis(2-chloroethyl) phosphate (BCEP), bis(1-chloro-2-propyl) phosphate (BCPP) and bis(1,3-dichloro-2-propyl) phosphate (BDCIPP). Separation was achieved in less than 3 min on a short column with narrow diameter and small particle size (50 mm × 2.1 mm × 1.7 μm). Different mobile phases were explored to obtain optimal sensitivity. Acetonitrile/water buffered with 5 mM of ammonium hydroxide/ammonium formate (pH 9.2) was the preferred mobile phase. Quantification of DAPs was performed using deuterated analogues as internal standards in synthetic urine (averaged DAP accuracy was 101%; RSD 3%). Low method limits of quantification (MLQ) were obtained for DNBP (0.40 ng mL−1), DPHP (0.10 ng mL−1), BDCIPP (0.40 ng mL−1) and BBOEP (0.60 ng mL−1), but not for the most polar DAPs, BCEP (∼12 ng mL−1) and BCPP (∼25 ng mL−1). The feasibility of the method was tested on 84 morning urine samples from 42 mother and child pairs. Only DPHP was found above the MLQ in the urine samples with geometric mean (GM) concentrations of 1.1 ng mL−1 and 0.57 ng mL−1 for mothers and children respectively. BDCIPP was however, detected above the method limit of detection (MLD) with GM of 0.13 ng mL−1 and 0.20 ng mL−1. While occasionally detected, the GM of DNBP and BBOEP were below MLD in both groups.  相似文献   

19.
A simple and rapid method based on solid-phase micro extraction (SPME) technique followed by gas chromatography-mass spectrometry with selected ion monitoring (GC-MS, SIM) was developed by the simultaneous determination of 16 pesticides of seven different chemical groups [Six organophosphorus (trichlorfon, diazinon, methyl parathion, malathion, fenthion and ethyon), three pyrethroids (bifenhin, permethrin, cypermethrin), two imidazoles (imazalil and prochloraz), two strobilurins (azoxystrobin and pyraclostrobin), one carbamate (carbofuran), one tetrazine (clofentezine), and one triazole (difenoconazole)] in water. The pesticides extraction was done with direct immersion mode (DI-SPME) of the polyacrilate fiber (PA 85 µm). The extraction temperature was adjusted to 50 °C during 30 min, while stirring at 250 rpm was applied. After extraction, the fiber was introduced in the GC injector for thermal desorption for 5 min. at 280 °C. The method was validated using ultra pure water samples fortified with pesticides at different concentration levels and shows good linearity in the concentrations between 0.05 and 250.00 ng mL− 1. The LOD and LOQ ranged, from 0.02 to 0.30 ng mL− 1 and 0.05 to 1.00 ng mL− 1, respectively. Intra-day and inter-day precisions were determined in two concentration levels (5.00 and 50.00 ng mL− 1). Intra-day relative standard deviation (%R.S.D.) ranged between 3.6 and 13.6%, and inter-day (%R.S.D.) ranged between 6.3 and 18.5%. Relative recovery tests were carried out spiking the ultra pure sample with standards in three different concentration levels 0.20, 5.00 and 50.00 ng mL− 1. The recovery at 0.20 ng mL− 1 level varied from 86.4 ± 9.4% to 108.5 ± 10.5%, at 5.00 ng mL− 1 level varied from 77.5 ± 10.8% to 104.6 ± 9.6% and at 50.00 ng mL− 1 level varied from 70.2 ± 4.6% to 98.4 ± 8.5%. The proposed SPME method was applied in twenty-six water samples collected in the “Platô de Neópolis”, State of Sergipe, Brazil. Methyl parathion was detected in five samples with an average concentration of 0.17 ng mL− 1 and bifenthrin, pyraclostrobin and azoxystrobin residues were found in three samples with average concentrations of 2.28, 3.12 and 0.15 ng mL− 1, respectively.  相似文献   

20.
We describe here a method for detecting and quantifying the highly carcinogenic polycyclic aromatic hydrocarbon (PAH) benzo[a]pyrene (BaP) in water, based on a flow-trough optical sensor. The technique is fast (response time of 40 s) and simple and at the same time meets the standards of sensitivity and selectivity required by the European Guidelines on Water for Human Consumption. The optosensor is based on the on-line immobilization of BaP on a non-ionic resin (Amberlite XAD-4) solid support in a continuous-flow system. BaP was analyzed in a 15 mM H2PO4/HPO42− buffer solution with 25% (v/v) 1,4-dioxane at pH 7. Fluorescence intensity was measured at λex/em=392/406 nm. The experimental conditions (reagent phase, pH, type and concentration of buffer solution and organic solvent) and flow-injection values (flow rate and injection volume) were carefully controlled. Under these conditions the optosensor was sensitive to a linear concentration range of between 3.0 and 250.0 ng l−1 with a detection limit of 3.0 ng l−1 and a standard deviation of 1.5% at 150 ng l−1. The optosensor was applied to the quantification of BaP in drinking and waste water samples (95-105% recovery) in presence of the other 15 EPA PAHs at 1000 ng l−1 concentration level. The influence of other fluorescent polycyclic aromatic hydrocarbons and potential interference from ions usually present in water was also evaluated.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号