首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
In the course of systematic studies on surface layer (S-layer) glycoproteins of bacilli, the chloroform/methanol extract from whole cells of Geobacillus stearothermophilus NRS 2004/3a has been submitted to MS analysis. Glucosylated cardiolipins were found as minor components of the total lipid and phospholipid mixture by de novo identification. After purification of the crude extract using a combined column chromatography/2D TLC protocol, structural investigations of components in the lipid fraction by high resolution ESI-QTOF MS analysis provided evidence about homologous molecules attributable to the cardiolipin species containing a glycosylated backbone, and about a diversity of ester-linked fatty acid substituents. In comparative studies by positive and negative ion nanoESI-QTOF-CID-MS, maps of cardiolipin molecular ions were obtained, followed by MS/MS of the most abundant species, to provide structural details of D-glucopyranosylcardiolipin and the fatty acid substituent patterns. Experiments of the parent ion scan type revealed the presence of fatty acid moieties as isobaric combinations, represented in single molecular ion species.  相似文献   

2.
Matrix-assisted laser desorption/ionization (MALDI) time-of-flight (ToF) mass spectrometry (MS) is an established tool for analyzing high mass molecules, such as proteins, whereas it attracts far less interest in the field of lipid analysis. In the study reported here a new chlorosulfolipid (CSL), 3,8,12,15-tetrachloroeicosane-1,17,18-triyl tris(hydrogen sulfate), was identified from the alga Ochromonas danica and de novo characterized by matrix-assisted laser desorption/ionization quadrupole ion trap time-of-flight (MALDI-QIT-ToF) MS in negative ion mode. This method provides an effective alternative for the analysis of compounds directly derived from organic cell extracts. For MALDI analyses several frequently used solid MALDI matrices as well as some ionic liquid matrices (ILMs) were tested to enhance the analyte response to UV-laser and its ionization. The molecular weight of the observed compound could be determined as Li-, Na- and K-adducts [M+Me-2H]-. The characteristic isotopic patterns of the measured ions and the well-allocated molecular fragments by MS1, MS2 and MS3 indicate the fourfold chlorination and threefold sulfation of the investigated compound. The MS fragmentation alongside of the chlorine-bearing C-atoms is accompanied by the generation of a double bond at the opposite fragment in MS1. This obtained fragmentation pattern provides an insight into the allocation of the chlorine-bearing C-atoms along the carbon chain.  相似文献   

3.
Reconstructed ion chromatograms have been used to identify relevant high performance liquid chromatography (HPLC) peaks in a directly coupled high performance liquid chromatography/nuclear magnetic resonance spectroscopy/mass spectrometry (HPLC/NMR/MS) experiment. This has been applied to a study of the metabolism of a model compound, 5-nitropyridone (2-hydroxy-5-nitropyridine), in maize plants grown hydroponically. By monitoring the on-flow reconstructed ion chromatogram corresponding to the 5-nitropyridone fragment at m/z 143, and additional molecular ions corresponding to metabolites identified as products from similar compounds, relevant peaks were identified rapidly for subsequent stopped-flow 1H NMR spectroscopic analysis. The combination of coupled HPLC/NMR/MS enabled the direct identification of three metabolites, namely the N-glucoside, N-malonylglucoside, and O-malonylglucoside. This work demonstrates the power of HPLC/NMR/MS for the structural elucidation of xenobiotic metabolites in complex biological matrices (such as plant material) with minimal sample preparation. In particular, using mass spectrometry for the initial identification of relevant HPLC peaks allows the analysis of complex samples without the necessity for other spectroscopic markers, such as 19F NMR signal for fluorinated compounds or UV spectroscopy for molecules with strong UV chromophores.  相似文献   

4.
The reagents 19 hydrazide and 14 hydrazine were examined to function as reactive matrices for matrix‐assisted laser desorption/ionization mass spectrometry (MALDI‐MS) to detect gaseous aldehydes. Among them, two hydrazide (2‐hydroxybenzohydrazide and 3‐hydroxy‐2‐naphthoic acid hydrazide) and two hydrazine reagents [2‐hydrazinoquinoline and 2,4‐dinitrophenylhydrazine (DNPH)] were found to react efficiently with carbonyl groups of gaseous aldehydes (formaldehyde, acetaldehyde and propionaldehyde); these are the main factors for sick building syndrome and operate as reactive matrices for MALDI‐MS. Results from accurate mass measurements by JMS‐S3000 Spiral‐TOF suggested that protonated ion peaks corresponding to [M + H]+ from the resulting derivatives were observed in all cases with the gaseous aldehydes in an incubation, time‐dependent manner. The two hydrazide and two hydrazine reagents all possessed absorbances at 337 nm (wavelength of MALDI nitrogen laser), with, significant electrical conductivity of the matrix crystal and functional groups, such as hydroxy group and amino group, being important for desorption/ionization efficiency in MALDI‐MS. To our knowledge, this is the first report that gaseous molecules could be derivatized and detected directly in a single step by MALDI‐MS using novel reactive matrices that were derivatizing agents with the ability to enhance desorption/ionization efficiency. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

5.
郑姝宁  张延国  吕军  徐东辉 《色谱》2017,35(2):169-177
建立了超高效液相色谱-飞行时间-串联质谱(UPLC-TOF-MS/MS)分析大白菜叶片中脂质的种类、结构、脂肪酸组成并检测其相对含量的方法。以Acquity UPLCTMBEH C8色谱柱为固定相,采用飞行时间质谱全扫描-信息关联采集-子离子扫描(TOF-MS scan-IDA-product ion scan)复合模式实现一次进样分析,同时获得脂质的一级和二级质谱信息。在大白菜叶片中共鉴定得到232种脂质,包含104种磷脂、63种糖脂和65种甘油酯。其中,磷脂、糖脂和甘油酯中的主要成分分别为磷脂酰胆碱、单半乳糖二酰甘油和甘油二酯、甘油三酯。结果表明,该方法具有灵敏度高、准确度高和高通量等优点,为植物脂质的代谢研究提供了可靠的分析技术平台,并为进一步的脂质生物学功能研究奠定了基础。  相似文献   

6.
The specific matrix used in matrix‐assisted laser desorption/ionization imaging mass spectrometry (MALDI IMS) can have an effect on the molecules ionized from a tissue sample. The sensitivity for distinct classes of biomolecules can vary when employing different MALDI matrices. Here, we compare the intensities of various lipid subclasses measured by Fourier transform ion cyclotron resonance (FT‐ICR) IMS of murine liver tissue when using 9‐aminoacridine (9AA), 5‐chloro‐2‐mercaptobenzothiazole (CMBT), 1,5‐diaminonaphthalene (DAN), 2,5‐Dihydroxyacetophenone (DHA), and 2,5‐dihydroxybenzoic acid (DHB). Principal component analysis and receiver operating characteristic curve analysis revealed significant matrix effects on the relative signal intensities observed for different lipid subclasses and adducts. Comparison of spectral profiles and quantitative assessment of the number and intensity of species from each lipid subclass showed that each matrix produces unique lipid signals. In positive ion mode, matrix application methods played a role in the MALDI analysis for different cationic species. Comparisons of different methods for the application of DHA showed a significant increase in the intensity of sodiated and potassiated analytes when using an aerosol sprayer. In negative ion mode, lipid profiles generated using DAN were significantly different than all other matrices tested. This difference was found to be driven by modification of phosphatidylcholines during ionization that enables them to be detected in negative ion mode. These modified phosphatidylcholines are isomeric with common phosphatidylethanolamines confounding MALDI IMS analysis when using DAN. These results show an experimental basis of MALDI analyses when analyzing lipids from tissue and allow for more informed selection of MALDI matrices when performing lipid IMS experiments.  相似文献   

7.
During routine liquid chromatography/tandem mass spectrometric (LC/MS/MS) bioanalysis of a small molecule analyte in rat serum samples from a toxicokinetic study, an unexpected interfering peak was observed in the extracted ion chromatogram of the internal standard. No interfering peaks were observed in the extracted ion chromatogram of the analyte. The dose‐dependent peak area response and peak area response versus time profiles of the interfering peak suggested that it might have been related to a metabolite of the dosed compound. Further investigation using high‐resolution mass spectrometry led to unequivocal identification of the interfering peak as an N‐desmethyl metabolite of the parent analyte. High‐resolution mass spectrometry (HRMS) was also used to demonstrate that the interfering response of the metabolite in the multiple reaction monitoring (MRM) channel of the internal standard was due to an isobaric relationship between the 13C‐isotope of the metabolite and the internal standard (i.e., common precursor ion mass), coupled with a metabolite product ion with identical mass to the product ion used in the MRM transition of the internal standard. These results emphasize (1) the need to carefully evaluate internal standard candidates with regard to potential interferences from metabolites during LC/MS/MS method development, validation and bioanalysis of small molecule analytes in biological matrices; (2) the value of HRMS as a tool to investigate unexpected interferences encountered during LC/MS/MS analysis of small molecules in biological matrices; and (3) the potential for interference regardless of choice of IS and therefore the importance of conducting assay robustness on incurred in vitro or in vivo study samples. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

8.
Liquid chromatography‐tandem mass spectrometry (LC‐MS/MS) in the multiple reaction monitoring (MRM) scan mode has been the primary MS method applied for the target identification of specific and minor oxylipids in complex matrices, such as eicosanoids and docosanoids, which are potent lipid mediators derived from polyunsaturated fatty acid oxygenation. However, the high specificity of MRM can limit the detection of species with m/z MRM transitions not covered by the method. In addition to MRM, tandem‐quadrupole mass analyzers enable other experiments to be conducted, by fragmenting ions via collision‐induced dissociation process (CID). This paper presents the potential of tandem mass spectrometry for the focused analysis of oxylipids. We have successfully developed an LC‐MS/MS method for the identification of precursor ions of m/z 115, a diagnostic product ion of 5‐hydroxy‐ and 5‐epoxy‐fatty acids. As a proof of concept, the developed method was used to discover several oxylipids oxidized at C5 derived from arachidonic acid (C20 : 4) oxygenation in a hypothalamus rat extract that were not identified using the target MRM methodology. The proposed focused MS/MS‐based approach in a tandem mass analyzer has proven to be a powerful strategy to accelerate the identification of oxylipids with structural similarities and assist the field of lipidomic research. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

9.
The analysis of low molecular weight (LMW) compounds is of great interest to detect small pharmaceutical drugs rapidly and sensitively, or to trace and understand metabolic pathways. Matrix-assisted laser desorption/ionization mass spectrometry (MALDI MS) plays a central role in the analysis of high molecular weight (bio)molecules. However, its application for LMW compounds is restricted by spectral interferences in the low m/z region, which are produced by conventional organic matrices. Several strategies regarding sample preparation have been investigated to overcome this problem. A different rationale is centred on developing new matrices which not only meet the fundamental requirements of good absorption and high ionization efficiency, but are also vacuum stable and “MALDI silent”, i. e., do not give matrix-related signals in the LMW area. This review gives an overview on the rational design strategies used to develop matrix systems for the analysis of LMW compounds, focusing on (i) the modification of well-known matrices, (ii) the search for high molecular weight matrices, (iii) the development of binary, hybrid and nanomaterial-based matrices, (iv) the advance of reactive matrices and (v) the progress made regarding matrices for negative or dual polarity mode.  相似文献   

10.
Oxidation of polyunsaturated fatty acids containing phospholipids in tissue generates lipid hydroperoxides, which are further degraded to several products, among which unsaturated aldehydes such as 4-hydroxy-trans-2-nonenal (HNE) play an important role in mediating the pathological effects of oxidative stress. While the reaction of HNE with glutathione (GSH) is a well recognized pathway of detoxification in biological systems, no data are available on HNE interactions with carnosine, a dipeptide (beta-alanyl-L-histidine) present in high concentration in skeletal muscle. The aim of this work was to study the quenching ability of carnosine towards HNE and to characterize the reaction products by electrospray ionization tandem mass spectrometry (ESI-MS/MS), using GSH as a model peptide. GSH incubation with HNE in 1 mM phosphate buffer (pH 7.4) results in the complete disappearance of HNE within 1 h owing to the formation of a Michael adduct, S-(4-hydroxynonanal-3-yl)glutathione. The reaction of HNE with carnosine was studied in different molar ratios and monitored up to 24 h by high-performance liquid chromatography (HPLC) (HNE consumption), MS/MS (infusion) and liquid chromatography mass spectrometry (LC/MS) experiments. Carnosine, although less reactive than GSH, significantly quenched HNE (48.2 +/- 0.9% HNE consumption after 1 h; carnosine:HNE molar ratio 10 : 1). Two reaction products were identified: the Michael adduct, N-(4-hydroxynonanal-3-yl)carnosine involving the imidazolic nitrogen of histidine, and the imine adduct, involving the amino group of the beta-alanine residue. Definitive structure assignment was achieved by chemical reduction with NaBH(4) and multinuclear magnetic resonance experiments. To understand whether carnosine acts as a quencher of unsaturated aldehydes in biological matrices, rat skeletal muscle homogenate was incubated with HNE and the formation of conjugated adducts was determined by LC/MS analysis. Three main products were detected and identified as Michael adducts of HNE with GSH, carnosine and anserine (the N-methylated derivative of carnosine, present in high concentrations in rat muscle). The results indicate that beside GSH, histidine-containing dipeptides could be involved in the detoxification pathway of reactive aldehydes from lipid peroxidation generated in skeletal muscle during physical endurance.  相似文献   

11.
Hybrid chemical ionization (HCI), a new and useful alternative to conventional chemical ionization mass spectrometry, has been applied to the analysis of the pharmaceutical diclofenac in wastewater samples. This technique takes advantage of the high versatility of ion trap (IT) spectrometers combined with external ionization sources. In hybrid configuration, reagent ions are generated in the external source through electron ionisation (EI) of a reagent gas. These reagent ions are then drawn into the ion trap and only those selected are allowed to react with analytes eluting from the GC column. These ion-molecule reactions create analyte ions which are held in the ion trap. In this study ion-molecule reactions between C(3)F(5)(+) cations, generated from perfluorotributylamine (FC43), and diclofenac molecules have been investigated. The observed reaction products were [M+C(3)F(5)-H(2)O](+) adduct ions, which result from the initial electrophilic addition of C(3)F(5)(+) cations to the diclofenac molecule followed by the rapid loss of H(2)O. Further fragmentation of these ions by MS/MS yielded enough daughter ions for a reliable identification of diclofenac in complex matrices. The GC-HCI-MS/MS method applied to wastewater samples provided highly enhanced selectivity and sensibility, with a detection limit in real samples of 3.0 ng/L, for a solid-phase extraction (SPE) pre-concentration factor of 400. Other performance characteristics of the method, such as linearity and precision were also satisfactory. Finally, the method was successfully applied to the analysis of wastewater samples taken from the effluent of an urban sewage treatment plant (STP).  相似文献   

12.
The application of a new hybrid RF/DC quadrupole-linear ion trap mass spectrometer to support drug metabolism and pharmacokinetic studies is described. The instrument is based on a quadrupole ion path and is capable of conventional tandem mass spectrometry (MS/MS) as well as several high-sensitivity ion trap MS scans using the final quadrupole as a linear ion trap. Several pharmaceutical compounds, including trocade, remikiren and tolcapone, were used to evaluate the capabilities of the system with positive and negative turbo ionspray, using either information-dependent data acquisition (IDA) or targeted analysis for the screening, identification and quantification of metabolites. Owing to the MS/MS in-space configuration, quadrupole-like CID spectra with ion trap sensitivity can be obtained without the classical low mass cutoff of 3D ion traps. The system also has MS(3) capability which allows fragmentation cascades to be followed. The combination of constant neutral loss or precursor ion scan with the enhanced product ion scan was found to be very selective for identifying metabolites at the picogram level in very complex matrices. Owing to the very high cycle time and, depending on the mass range, up to eight different MS experiments could be performed simultaneously without compromising chromatographic performance. Targeted product ion analysis was found to be complementary to IDA, in particular for very low concentrations. Comparable sensitivity was found in enhanced product ion scan and selected reaction monitoring modes. The instrument is particularly suitable for both qualitative and quantitative analysis.  相似文献   

13.
A matrix‐assisted laser desorption/ionization time of flight/time of flight tandem mass spectrometer (MALDI TOF/TOF) has been used for high‐speed precursor/fragment ion transition image acquisition. High‐throughput analysis is facilitated by an Nd:YLF solid state laser capable of pulse repetition rates up to 5 kHz, a high digitizer acquisition rate (up to 50 pixels/s), and continuous laser raster sampling. MS/MS experiments are enabled through the use of a precision timed ion selector, second source acceleration, and a dedicated collision cell. Continuous raster sampling is shown here to facilitate rapid MS/MS ion image acquisition from thin tissue sections for the drug rifampicin and for a common kidney lipid, SM4s(d18:1/24:1). The ability to confirm the structural identity of an analyte as part of the MS/MS imaging experiment is an essential part of the analysis. Additionally, the increase in sensitivity and specificity afforded by an MS/MS approach is highly advantageous, especially when interrogating complex chemical environments such as those in biological tissues. Herein, we report continuous laser raster sampling TOF/TOF imaging methodologies which demonstrate 8 to 14‐fold increases in throughput compared with existing MS/MS instrumentation, an important advantage when imaging large areas on tissues. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

14.
Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) does not work efficiently on small molecules (usually with molecular weight below 500 Da) because of the interference of matrix-related peaks in low m/z region. The previous methods developed for this problem focused on reducing the peaks caused by the traditional matrices. Here, we report a novel strategy to analyze small molecules in a high and interference-free mass range by using metal-phthalocyanines (MPcs) as matrices which should be capable of forming matrix-analyte adducts. The mass of the target analyte was calculated by subtracting the mass of MPc from the mass of the MPc-analyte adduct. MPcs were also detectable and could serve as internal standards. Various MPcs with aromatic or aliphatic groups and different metal centers were then synthesized and explored. Aluminum-phthalocyanines (AlPcs), gallium-phthalocyanines (GaPcs), and indium-phthalocyanines (InPcs) were efficient matrices to form MPc-analyte adducts in either the positive or negative ion mode. The detection limits varied from 17 to 75 fmol, depending on analyte types. The mechanism of adducts formation was also proposed. Collectively, our strategy provides a novel and efficient way to analyze small molecules by MALDI-TOF MS.  相似文献   

15.
This article describes the technique of fast atom bombardment mass spectrometry (FAB MS) and its applications to the analysis of organometallic and coordination complexes. Sections on ion generation and matrices are followed by a Periodic Group-based review of FAB MS results obtained from Transition Metal and Main Group compounds, organometallic cluster carbonyls and their derivatives, and salts of poly-oxo-anions. The literature has been surveyed from 1981 to approximately mid-1986.  相似文献   

16.
Hybrid quadrupole time-of-flight mass spectrometry (QTOF MS) has gained wide acceptance in many fields of chemistry, for example, proteomics, metabolomics and small molecule analysis. This has been due to the numerous technological advances made to this mass analyser in recent years. In the environmental field, the instrument has proven to be one of the most powerful approaches for the screening of organic pollutants in different matrices due to its high sensitivity in full acquisition mode and mass accuracy measurements. In the work presented here, the optimum experimental conditions for the creation of an empirical TOF MS spectra library have been evaluated. For this model we have used a QTOF Premier mass spectrometer and investigated its functionalities to obtain the best MS data, mainly in terms of mass accuracy, dynamic range and sensitivity. Different parameters that can affect mass accuracy, such as lock mass, ion abundance, spectral resolution, instrument calibration or matrix effect, have also been carefully evaluated using test compounds (mainly pesticides and antibiotics). The role of ultra-high-pressure liquid chromatography (UHPLC), especially when dealing with complex matrices, has also been tested. In addition to the mass accuracy measurements, this analyser allows the simultaneous acquisition of low and high collision energy spectra. This acquisition mode greatly enhances the reliable identification of detected compounds due to the useful (de)protonated molecule and fragment ion accurate mass information obtained when working in this mode. An in-house empirical spectral library was built for approximately 230 organic pollutants making use of QTOF MS in MS(E) mode. All the information reported in this paper is made available to the readers to facilitate screening and identification of relevant organic pollutants by QTOF MS.  相似文献   

17.
Sphingolipids have hydrophilic and hydrophobic properties, different saturation and combination of the oligosaccharide chains and mass homology of species located in a narrow m/z region hampering their recognition. To target sphingolipids for diagnostic purposes, standardized methods for lipid extraction, quali‐ and quantitative assessments are required. In this study, HPTLC‐MALDI MS was adopted to establish sphingolipid and glycosphingolipid profiles in muscle, brain and serum to create a database of molecules to be searched in the preclinical and clinical investigations. Specific protocols for lipid extraction were set up based on the characteristics of the tissue or/and fluids; this approach maximizes the HPTLC‐MALDI MS analytical throughput both for lipids extracted in organic and aqueous phase. This study indicates that alkaline hydrolysis is necessary for the detection of low abundant species such as Gb3Cer and ceramides in serum and Gb4Cer, CerP and HexCer in muscle tissue. The high hydrophobicity of ceramides has been overcome by the development of HPTLC plate in chloroform:methanol/50:3.5, which increases the number and the intensity of low abundant Cer species. MS/MS analysis has been conducted directly on HPTLC plate allowing the molecular recognition; furthermore a dataset of spectra was acquired to create a database for future profiling of these molecules.  相似文献   

18.
Acceleration of liquid chromatography/mass spectrometric (LC/MS) analysis for metabolite identification critically relies on effective data processing since the rate of data acquisition is much faster than the rate of data mining. The rapid and accurate identification of metabolite peaks from complex LC/MS data is a key component to speeding up the process. Current approaches routinely use selected ion chromatograms that can suffer severely from matrix effects. This paper describes a new method to automatically extract and filter metabolite-related information from LC/MS data obtained at unit mass resolution in the presence of complex biological matrices. This approach is illustrated by LC/MS analysis of the metabolites of verapamil from a rat microsome incubation spiked with biological matrix (bile). MS data were acquired in profile mode on a unit mass resolution triple-quadrupole instrument, externally calibrated using a unique procedure that corrects for both mass axis and mass spectral peak shape to facilitate metabolite identification with high mass accuracy. Through the double-filtering effects of accurate mass and isotope profile, conventional extracted ion chromatograms corresponding to the parent drug (verapamil at m/z 455), demethylated verapamil (m/z 441), and dealkylated verapamil (m/z 291), that contained substantial false-positive peaks, were simplified into chromatograms that are substantially free from matrix interferences. These filtered chromatograms approach what would have been obtained by using a radioactivity detector to detect radio-labeled metabolites of interest.  相似文献   

19.
Electrospray ionization (ESI) in combination with Fourier transform ion cyclotron resonance (FTICR) mass spectrometry provides for mass analysis of biological molecules with unrivaled mass accuracy, resolving power and sensitivity. However, ESI FTICR MS performance with on-line separation techniques such as liquid chromatography (LC) and capillary electrophoresis has to date been limited primarily by pulsed gas assisted accumulation and the incompatibility of the associated pump-down time with the frequent ion beam sampling requirement of on-line chromatographic separation. Here we describe numerous analytical advantages that accrue by trapping ions at high pressure in the first rf-only octupole of a dual octupole ion injection system before ion transfer to the ion trap in the center of the magnet for high performance mass analysis at low pressure. The new configuration improves the duty cycle for analysis of continuously generated ions, and is thus ideally suited for on-line chromatographic applications. LC/ESI FTICR MS is demonstrated on a mixture of 500 fmol of each of three peptides. Additional improvements include a fivefold increase in signal-to-noise ratio and resolving power compared to prior methods on our instrument.  相似文献   

20.
Inductively coupled plasma (ICP) mass spectrometry (MS) is routinely used in many diverse research fields such as earth, environmental, life and forensic sciences and in food, material, chemical, semiconductor and nuclear industries. The high ion density and the high temperature in a plasma provide an ideal atomizer and element ionizer for all types of samples and matrices introduced by a variety of specialized devices. Outstanding properties such as high sensitivity (ppt-ppq), relative salt tolerance, compound-independent element response and highest quantitation accuracy lead to the unchallenged performance of ICP MS in efficiently detecting, identifying and reliably quantifying trace elements. The increasing availability of relevant reference compounds and high separation selectivity extend the molecular identification capability of ICP MS hyphenated to species-specific separation techniques. While molecular ion source MS is specialized in determining the structure of unknown molecules, ICP MS is an efficient and highly sensitive tool for target-element orientated discoveries of relevant and unknown compounds. This special-feature, tutorial article presents the principle and advantages of ICP MS, highlighting these using examples from recently published investigations.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号