首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
提供了一种利用体积排阻色谱-光散射(SEC-LS)联用技术来解决二元复杂共混体系组成的定量分析问题.基于体积排除色谱的绝对定量化原则,首先从理论上分析了共混物的光散射响应因子与组成呈线性关系.通过分析六组复杂共混体系的光散射响应因子与组成的关系,验证了该线性关系确实存在.进而利用该线性关系计算了共混体系的组成.在某些共混体系中,通过光散射响应因子得出的组成比利用示差法得出的组成更加接近原料组成.通过分析这两种方法产生误差的来源,阐述了产生该现象的原因.  相似文献   

2.
程镕时 《高分子科学》2010,28(3):291-297
<正>Base on the principle of absolute quantification of size exclusion chromatography(SEC),a light scattering(LS) detector coupled with a concentration detector(refractive index detector) is utilized to determine the compositions of complicated binary mixtures.A theoretical analysis predicts that the response factors for both LS and RI detectors are linear functions with the composition of any specified polymer mixtures in the binary polymer mixtures.Two pairs of complicated binary mixtures were used to test the theory mentioned in the present paper,and the experimental results show an excellent accordance with the theory.  相似文献   

3.
The paper describes a new procedure for the determination of boiling point distribution of high‐boiling petroleum fractions using size‐exclusion chromatography with refractive index detection. Thus far, the determination of boiling range distribution by chromatography has been accomplished using simulated distillation with gas chromatography with flame ionization detection. This study revealed that in spite of substantial differences in the separation mechanism and the detection mode, the size‐exclusion chromatography technique yields similar results for the determination of boiling point distribution compared with simulated distillation and novel empty column gas chromatography. The developed procedure using size‐exclusion chromatography has a substantial applicability, especially for the determination of exact final boiling point values for high‐boiling mixtures, for which a standard high‐temperature simulated distillation would have to be used. In this case, the precision of final boiling point determination is low due to the high final temperatures of the gas chromatograph oven and an insufficient thermal stability of both the gas chromatography stationary phase and the sample. Additionally, the use of high‐performance liquid chromatography detectors more sensitive than refractive index detection allows a lower detection limit for high‐molar‐mass aromatic compounds, and thus increases the sensitivity of final boiling point determination.  相似文献   

4.
讨论了示差折光和光散射联用双检测体积排除色谱的绝对定量化的原理,强调指出了试样注入量在数据处理中的重要作用.测量注入试样的这两种检测器的检测常数,可以同时得到试样的折光指数增量和重均分子量的绝对值.这一方法除了适用于各种均聚物外,还可以应用于高分子混合物的分析.此时,如将混合物看作为单一溶质,从所得折光指数增量和重均分子量,可对它们的组成作出定量分析,还可以判断共混物两个组分之间有无分子缔合等现象的产生.这一方法应用于聚甲基丙烯酸甲酯/聚苯乙烯(PMMA/PS)混合物的溶液,指明在四氢呋喃中两者产生缔合而形成了复合物.  相似文献   

5.
To monitor polymer–polymer coupling reactions between two different monofunctional polymers in dilute polymer blends, fluorescence‐labeled anhydride‐functional polystyrene (PS) and poly(methyl methacrylate) (PMMA) were prepared by conventional anionic polymerization. Sequential trapping of lithiopolystyrene by 1‐(2‐anthryl)‐1‐phenylethylene (APE) and then di‐t‐butyl maleate (4) provided, after pyrolysis, anhydride‐functional fluorescent PS. Fluorescent PMMA anhydride (8) was synthesized with sec‐butyllithium/APE as an initiator for the anionic polymerization of methyl methacrylate, trapping by 4, and pyrolysis. These polymers could be reacted with amine‐functional polymers by melt blending, and the reaction progress could be monitored by gel permeation chromatography coupled with fluorescence detection. This technique not only allows monitoring of the coupling reaction with high sensitivity (ca. 100 times more sensitive than refractive index detection) but also permits selective detection because unlabeled polymers are invisible to fluorescence detection. This highly sensitive and selective detection methodology was also used to monitor the coupling reaction of 8 with PS‐NH2 at a thin‐film interface, which was otherwise difficult to detect by conventional methods. © 2000 John Wiley & Sons, Inc. J Polym Sci A: Polym Chem 38: 2177–2185, 2000  相似文献   

6.
The high performance liquid chromatography and gas chromatography methods were investigated for their applicability in determining micro-level concentrations of tri-n-butyl phosphate (TBP). A high performance liquid chromatograph (HPLC) equipped with refractive index detector was used in determining TBP up to 2 ppm concentration level in the aqueous nitric acid solutions. The gas chromatography incorporated with Thermionic Detector (NPD) and Flame Photometric Detector (FPD) were examined for their potential in analyzing TBP in organic phase up to sub-ppm level. The results indicated that HPLC-RI technique is well suited for direct analysis of aqueous phase. For organic phase analysis, gas chromatographic methods with the TID and FPD were suitable but performance of detectors deteriorated often due to fouling.  相似文献   

7.
Analysis of the physical properties of biotherapeutic proteins is crucial throughout all the stages of their lifecycle. Herein, we used size‐exclusion ultra high performance liquid chromatography coupled to multiangle light scattering and refractive index detection systems to determine the molar mass, mass‐average molar mass, molar‐mass dispersity and hydrodynamic radius of two monoclonal antibodies (rituximab and trastuzumab), a fusion protein (etanercept), and a synthetic copolymer (glatiramer acetate) employed as models. A customized instrument configuration was set to diminish band‐broadening effects and enhance sensitivity throughout detectors. The customized configuration showed a performance improvement with respect to the high‐performance liquid chromatography standard configuration, as observed by a 3 h column conditioning and a higher resolution analysis in 20 min. Analysis of the two monoclonal antibodies showed averaged values of 148.0 kDa for mass‐average molar mass and 5.4 nm for hydrodynamic radius, whereas for etanercept these values were 124.2 kDa and 6.9 nm, respectively. Molar‐mass dispersity was 1.000 on average for these proteins. Regarding glatiramer acetate, a molar mass range from 3 to 45 kDa and a molar‐mass dispersity of 1.304 were consistent with its intrinsic peptide diversity, and its mass‐average molar mass was 10.4 kDa. Overall, this method demonstrated an accurate determination of molar mass, overcoming the difficulties of size‐exclusion chromatography.  相似文献   

8.
A new technique of liquid chromatography, which allows baseline separation of fatty alcohol ethoxylates with up to 15-20 ethylene oxide units under isocratic conditions allows an accurate quantitative analysis of single hydrophobic chain surfactants. Using density and refractive index detection, the accurate weight fractions of the individual oligomers are obtained. Moreover, the contribution of preferential solvation can be determined. With refractive index detection alone, good accuracy can also be achieved.  相似文献   

9.
A technique of using size exclusion chromatography (SEC) with the Corona charged aerosol detector (CAD) was developed and evaluated in comparison with refractive index (RI) and evaporative light scattering detection (ELSD) for fast screening of polyethylene glycol (PEG), a polymer used in preparing pegylated pharmaceutical compounds. These detection techniques were used in the analysis of multiple lots of PEG reagents. CAD was found to provide more accurate impurity and polydispersity profiles of PEG reagents that better differentiate their quality, while RI was not suitable for this application due to its low sensitivity and ELSD led to underestimation of the impurity and polydispersity. The accuracy of polydispersity determination by SEC-CAD was validated against a commercial reference standard of known polydispersity. The SEC-CAD technique and the observed differences between the three detectors can also be applied to polymer analysis in general.  相似文献   

10.
Polymer manufacturers add antioxidants, waxes, dyes, and other materials to enhance polymer utility or processing. Numerous analytical methods are available to characterize various chemical aspects of polymers including methods interfaced with mass spectrometry (MS) such as pyrolysis (Py), gas chromatography (GC), liquid chromatography (LC), and thermogravimetric analysis (TGA). Current methods work well, but because of the necessity of extraction, chromatography, or thermal methods, most are too time consuming for high throughput analyses which might be necessary in, for example, regulatory laboratories. Here we discuss three MS methods for rapid analysis of polymers; multi-sample MALDI MS which allows rapid analysis of low molecular weight polymers, atmospheric pressure (AP) solids analysis probe MS for direct ambient additives analysis, and APPy MS for polymer identification. The latter methods provide information regardless of the composition or molecular weight of the polymeric material.  相似文献   

11.
To date, several methods for the quantification of tamoxifen and its metabolites have been developed, most of which employ liquid chromatography tandem–mass spectrometry (LC–MS/MS). These methods are highly sensitive and reproducible, but are also time‐consuming and require expensive equipment; one of their main disadvantages is matrix ionization effects. A more viable option, particularly in developing countries, is high‐performance liquid chromatography coupled with UV or fluorescence detection. We developed and validated a method for simultaneous quantification of tamoxifen, endoxifen and 4‐hydroxytamoxifen based on high‐performance liquid chromatography with fluorescence detection in a reverse‐phase column. The method is rapid (16 min plus 5 min of column re‐equilibrium), accurate (80–100%) and precise (0.23–6.00%), and does not require any additional irradiation process. Sample pretreatment consists of protein precipitation with acetonitrile under alkaline conditions, employing only 200 μL plasma. The validated method's wide range allowed quantification of steady‐state levels in patients under standard tamoxifen treatment (20 mg/day). This assay is ready for application in clinical studies and routine quantification of tamoxifen, endoxifen and 4‐hydroxytamoxifen in healthcare institutions.  相似文献   

12.
The quantification of phospholipid classes and the determination of their molecular structures are crucial in physiological and medical studies. This paper's target analytes are cell membrane phospholipids, which play an important role in the seasonal acclimation processes of poikilothermic organisms. We introduce a set of simple and cost‐effective analytical methods that enable efficient characterization and quantification of particular phospholipid classes and the identification and relative distribution of the individual phospholipid species. The analytical approach involves solid‐phase extraction and high‐performance thin‐layer chromatography, which facilitate the separation of particular lipid classes. The obtained fractions are further transesterified to fatty acid methyl esters and subjected to gas chromatography coupled to flame ionization detection, which enables the determination of the position of double bonds. Phospholipid species separation is achieved by high‐performance liquid chromatography with mass spectrometry, which gives information about the headgroup moiety and attached fatty acids. The total content of each phospholipids class is assessed by phosphorus determination by UV spectrophotometry. The simultaneous analysis of phosphorus, fatty acid residues, and phospholipid species provides detailed information about phospholipid composition. Evaluation of these coupled methods was achieved by application to an insect model, Pyrrhocoris apterus. High correlation was observed between fatty acid compositions as determined by gas chromatography and high‐performance liquid chromatography analysis.  相似文献   

13.
This review documents recent advances in the design, synthesis, characterization, and application of molecularly imprinted polymers in the form of monoliths and particles/beads for the use in the separation and analysis of proteins with solid‐phase extraction or liquid chromatography. The merits of three‐dimensional molecular imprinting, whereby the molecular template is randomly embedded in the polymer, and two‐dimensional imprinting, in which the template is confined to the surface, are described. Target protein binding can be achieved by either using the entire protein as a template or by using a protein substructure as template, that is, a peptide, as in the "epitope" approach. The intended approach and strategy then determine the choice of polymerization method. A synopsis has been provided on methods used for the physical, chemical, and functional characterizations and associated performance evaluations of molecularly imprinted and nonimprinted control polymers, involving a diverse range of analytical techniques commonly used for low and high molecular mass analytes. Examples of recent applications demonstrate that, due to the versatility of imprinting methods, molecularly imprinted monoliths or particles/beads can be adapted to protein extraction/depletion and separation procedures relevant to, for example, protein biomarker detection and quantification in biomedical diagnostics and targeted proteomics.  相似文献   

14.
Emulsion polymerizations were used for preparing fluorescent-labeled polymers. The labeled polymers were analyzed by gel permeation chromatography (GPC) using both fluorescence (FL) and refractive index (RI) as detectors. The uniformity of polymer labeling was measured by the ratio between FL and RI signals, calculated by a computer software, on the basis of each GPC chromatogram. It was found that in emulsion polymerizations, the semicontinuous process can produce a more homogenous dye distribution in the host polymer molecules than the batch method. Uniform labeling of a polymer with various dyes can be achieved by the semi-continuous process. However, experimental conditions for polymerization, such as initiator concentration and the presence of surfactant or chain transfer agent, may influence the uniformity of dye distribution. © 1994 John Wiley & Sons, Inc.  相似文献   

15.
In this study, novel monodisperse restricted access media‐molecularly imprinted polymers were successfully prepared by surface initiated reversible addition‐fragmentation chain transfer polymerization using monodisperse crosslinked poly (glycidyl methacrylate‐co‐ethylene glycol dimethacrylate) microspheres as the carrier and acryloyl chloride‐modified β‐cyclodextrin as the hydrophilic functional monomer. The surface morphology, protein exclusion, and adsorption properties of the molecularly imprinted polymers were investigated. The results show that the material has excellent monodispersity and hydrophilicity, and simultaneously exhibit high adsorption capacity, fast binding kinetics, high selectivity, and significant thermal stability. The molecularly imprinted polymers as dispersive solid‐phase extraction adsorbent combined with reversed‐phase high‐performance liquid chromatography was used to selectively enrich, separate, and analyze trace 17β‐estradiol in milk samples. The recovery of 17β‐estradiol is 88–95% with relative standard deviation of <4%, and the limits of detection and quantification of this method are 2.08 and 9.29 µg/L, respectively. The novel restricted access media‐molecularly imprinted polymer adsorbents provide an effective method for the selective extraction and detection of 17β‐estradiol directly from complex samples.  相似文献   

16.
The great prevalence of thin‐layer chromatography over high‐performance liquid chromatography is connected with the possibility of analyzing many samples in parallel. Therefore, the method is often used in screening and/or effect directed analysis to compare composition and chemical/biological properties of many samples in one run. It was already proved, that high performance thin‐layer chromatography, in many cases, can replace high‐performance liquid chromatography for quantitative analysis. The main aim of the paper is to show that simple thin‐layer chromatography can also be used as a quantitative or at least as a semi‐quantitative method, even when it concerns effect directed analysis e.g. direct bioautography. Chlorogenic acid content was measured in four methanol extracts of various green coffees and in one extract of black coffee using thin‐layer chromatography with ultraviolet detection and thin‐layer chromatography with effect directed detection. High‐performance liquid chromatography was used as a reference method. Additionally, total contents of polyphenols and antioxidants were estimated using thin‐layer chromatography or dot‐blot on chromatography plates. These results were compared to spectrophotometric methods. It was proved that thin‐layer chromatography can be used as a quantitative (using densitometry) or semi‐quantitative method (using other detection methods including effect directed detection) as well as for estimating total antioxidants or polyphenols content.  相似文献   

17.
Multi-wavelength detectors offer improved detection capabilities for liquid chromatographic methods, but require improvements in data analysis methodology to utilize all the available information. In this work, various methods for improving the quantitative results obtained from liquid chromatography with full spectrum fluorescence detection were studied. The availability of multi-wavelenght information allows overlapped chromatographic peaks to be resolved. Different approaches were investigated for developing calibration models that use all of the available spectral information, and are compatible with a variety of methods for quantification, including factor analysis, Kalman filtering and rank annihilation. These methods were compared for their ability to resolve overlapped chromatographic peaks and their accuracy in quantification.  相似文献   

18.
A molecularly imprinted polymer has been synthesized to specifically extract adefovir, an antiviral drug, from serum and urine by dispersive solid‐phase extraction before high‐performance liquid chromatography with UV analysis. The imprinted polymers were prepared by bulk polymerization by a noncovalent imprinting method that involved the use of adefovir (template molecule) and functional monomer (methacrylic acid) complex prior to polymerization, ethylene glycol dimethacrylate as cross‐linker, and chloroform as porogen. Molecular recognition properties, binding capacity, and selectivity of the molecularly imprinted polymers were evaluated and the results show that the obtained polymers have high specific retention and enrichment for adefovir in aqueous medium. The new imprinted polymer was utilized as a molecular sorbent for the separation of adefovir from human serum and urine. The serum and urine extraction of adefovir by the molecularly imprinted polymer followed by high‐performance liquid chromatography showed a linear calibration curve in the range of 20–100 μg/L with excellent precisions (2.5 and 2.8% for 50 μg/L), respectively. The limit of detection and limit of quantization were determined in serum (7.62 and 15.1 μg/L), and urine (5.45 and 16 μg/L). The recoveries for serum and urine samples were found to be 88.2–93.5 and 84.3–90.2%, respectively.  相似文献   

19.
A comparative evaluation of ultraviolet, polarimetric, refractive index, and evaporative light-scattering detection coupled with high-performance liquid chromatography has been developed for the separation and quantitation of the enantiomers of chiral nonaromatic alcohols, some of which are intermediates in the synthesis of chiral drugs. (R,S)-3-tert-butylamino-1,2-propanediol; (R,S)-glycidol; and (R,S)-1-(4-morpholino)-2-octanol are selected as model compounds in order to compare the detection sensitivity and the linearity of the response with the four detectors. Separation of the enantiomers is performed using chiral stationary phases in normal-phase liquid chromatography. A one-day validation is achieved for (S)-3-tert-butylamino-1,2-propanediol with each detector, and limits of quantitation are determined for the three compounds. Advantages and limitations of the four detectors are discussed.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号