1.
Though not regulated in directives such as the Water Framework Directive of the European Union, the investigation of geogenic background concentrations of certain elements such as precious metals is of increasing interest, in particular for the early detection of a potential environmental pollution due to the increased use in various industrial and technological applications and in medicine. However, the precise and accurate quantification of precious metals in natural waters is challenging due to the complex matrices and the ultra-low concentrations in the (sub-) ng L−1 range. A methodological approach, based on matrix separation and pre-concentration on the strong anion exchange resin TEVA® Resin in an online mode directly coupled to ICP-SFMS, has been developed for the determination of Ag, Pt, Pd and Au in ground water. Membrane desolvation sample introduction was used to reduce oxide-based spectral interferences, which complicate the quantification of these metals with high accuracy. To overcome errors arising from matrix effects—in particular, the highly varying major ion composition of the investigated ground water samples—an isotope dilution analysis and quantification based on standard additions, respectively, were performed. The method allowed to process four samples per hour in a fully automated mode. With a sample volume of only 8 mL, enrichment factors of 6–9 could be achieved, yielding detection limits <1 ng L−1. Validation of the trueness was performed based on the reference samples. This method has been used for the analysis of the total concentrations of Ag, Pt, Pd and Au in highly mineralized ground waters collected from springs located in important geological fault zones of Austria’s territory. Concentrations ranges of 0.21–64.2 ng L−1 for Ag, 0.65–6.26 ng L−1 for Pd, 0.07–1.55 ng L−1 for Pt and 0.26–1.95 ng L−1 for Au were found.  相似文献   

2.
The use of highly toxic rocket fuel based on 1,1-dimethylhydrazine (UDMH) in many types of carrier rockets poses a threat to environment and human health associated with an ingress of UDMH into wastewater and natural reservoirs and its transformation with the formation of numerous toxic nitrogen-containing products. Their GC-MS quantification in aqueous samples requires matrix change and is challenging due to high polarity of analytes. To overcome this problem, accelerated water sample preparation (AWASP) based on the complete removal of water with anhydrous sodium sulfate and transferring analytes into dichloromethane was used. Twenty-nine UDMH transformation products including both the acyclic and heterocyclic compounds of various classes were chosen as target analytes. AWASP ensured attaining near quantitative extraction of 23 compounds with sample preparation procedure duration of no more than 5 min. Combination of AWASP with gas chromatography–mass spectrometry and using pyridine-d5 as an internal standard allowed for developing the rapid, simple, and low-cost method for simultaneous quantification of UDMH transformation products with detection limits of 1–5 μg L−1 and linear concentration range covering 4 orders of magnitude. The method has been validated and successfully tested in the analysis of aqueous solutions of rocket fuel subjected to oxidation with atmospheric oxygen, as well as pyrolytic gasification in supercritical water modelling wastewater from carrier rockets launch sites.  相似文献   

3.
Patulin (PAT) and citrinin (CTN) are the most common mycotoxins produced by Penicillium and Aspergillus species and are often associated with fruits and fruit by-products. Hence, simple and reliable methods for monitoring these toxins in foodstuffs are required for regular quality assessment. In this study, we aimed to establish a cost-effective method for detection and quantification of PAT and CTN in pome fruits, such as apples and pears, using high-performance liquid chromatography (HPLC) coupled with spectroscopic detectors without the need for any clean-up steps. The method showed good performance in the analysis of these mycotoxins in apple and pear fruit samples with recovery ranges of 55–97% for PAT and 84–101% for CTN, respectively. The limits of detection (LOD) of PAT and CTN in fruits were 0.006 µg/g and 0.001 µg/g, while their limits of quantification (LOQ) were 0.018 µg/g and 0.003 µg/g, respectively. The present findings indicate that the newly developed HPLC method provides rapid and accurate detection of PAT and CTN in fruits.  相似文献   

4.
A sensitive and reliable method was developed to determine methylene blue (MB) and its metabolite residues, including azure A (AZA), azure B (AZB), and azure C (AZC) in aquatic products by HPLC–MS/MS. The samples were extracted by acetonitrile and cleaned up by alumina-neutral (ALN) cartridges. The analytes were separated on a Sunfire C18 column (150 mm × 2.1 mm, 5 µm). The method was validated according to the European criteria of Commission Decision 2002/657/CE. Good linearity between 1–500 µg/L was obtained with correlation coefficients (R2) greater than 0.99. The limit of quantification (LOQ) was 1.0 µg/kg. The average recoveries at three levels of each compound (1, 5, and 10 µg/kg) were demonstrated to be in the range of 71.8–97.5%, with relative standard deviations (RSDs) from 1.05% to 8.63%. This method was suitable for the detection of methylene blue and its metabolite residues in aquatic products.  相似文献   

5.
Saccharides are the most common carbon source for Streptococcus thermophilus, which is a widely used bacterium in the production of fermented dairy products. The performance of the strain is influenced by the consumption of different saccharides during fermentation. Therefore, a precise measurement of the concentrations of saccharides in the fermentation media is essential. An 18-min long method with limits of quantitation in the range of 0.159–0.704 mg/L and with 13C labelled internal standards employing hydrophilic interaction chromatography coupled to mass spectrometric detection-(HILIC-LC-MS) allowed for simultaneous quantification of five saccharides: fructose, glucose, galactose, sucrose, and lactose in the fermentation samples. The method included a four-step sample preparation protocol, which could be easily applied to high-throughput analysis. The developed method was validated and applied to the fermentation samples produced by Streptococcus thermophilus.  相似文献   

6.
Guayule (Parthenium argentatum Gray) is a promising alternative source to Hevea brasiliensis for the production of natural rubber, which can reach levels of 8–9% under industrialized farming conditions. The most common method for determining rubber concentration is by accelerated solvent extraction (ASE), a technique developed by the Dionex Corporation and almost exclusively performed with the Dionex ASE-200 or 350 systems. Herein, it is sought to apply and adapt the most common methods used in the literature for the Dionex system to another extraction platform, the BÜCHI Speed Extractor E-914. Results showed that using a sand sandwich method to confine the sample in the center and exploiting a larger cell volume (80 mL) for extraction prevents the occurrence of overpressure and problems with clogging. Under optimized conditions, the coefficient of variation was <15% for both resin quantification for samples containing 5.0–15.8% of resin and for rubber quantification for samples with 1.7–10.3% rubber content. The extraction time for resin (2 cycles of 5 min each) was smaller than for rubber (2 cycles of 20 min each). It would be interesting to carry out interlaboratory comparisons to standardize the method at an international level.  相似文献   

7.
Triterpenoids have regained much attention as promising multi-targeting bioactive agents of natural origin in the treatment of numerous disorders. Due to the high potential for phytopharmaceutical development, accurate qualitative and quantitative analysis of triterpenoids for screening and quality control is required. Vaccinium vitis-idaea L. (lingonberry) raw materials have aroused interest as a rich source of triterpenoids. However, currently, no validated, rapid, and easy-to-perform quantification method is available for the routine control of these compounds in lingonberries. This research aimed at developing and validating HPLC-PDA methods for the determination and screening of triterpenoids in extracts of lingonberry leaves, fruits, and flowers. The developed methods were deemed satisfactory by validation, which revealed acceptable analytical specificity, linearity (r2 > 0.9999), precision (RSD < 2%), trueness (94.70–105.81%), and sensitivity (LOD: 0.08–0.65 µg/mL). The real sample analysis demonstrated established methods applicability for quantification of 13 triterpenoids in lingonberries and emphasized differences between raw materials. Lingonberry fruits were distinguished by the richness of ursolic acid; lingonberry flowers by similar profile to fruits, but low content of neutral triterpenoids; whereas lingonberry leaves by the particularly high level of α-amyrin. Thus, the proposed methods proved to be reliable and applicable for quantification and routine analysis of triterpenoids in lingonberry samples.  相似文献   

8.
A rapid and sensitive LC-MS/MS method was developed for the quantitative determination of sucrose esters (SEs) in Oriental tobacco samples. The sample preparation involved a 10-min sonication extraction procedure with acetone and five-fold dilution of the extract with methanol. The experiment was carried out in positive ion mode by ESI IT mass spectrometer. Because of lack of authentic standards of SEs, sucrose octa-acetate (internal standard, IS) was used as a surrogate to validate the proposed method. Matrix-matched standard calibration was used for quantification of IS in the spiked samples. Under optimized MS/MS conditions, an LOQ of 3.9 microg/g was achieved for IS, with an LOD of about 1.2 microg/g. Recoveries for IS were 95-97%. Among 19 monitored SEs, the contents of 11 SEs had RSDs lower than 13.7%. The method, with very little sample handling and good sensitivity, was applied to the rapid quantification of SEs in four Oriental tobacco samples. It appears that the sum of contents of the five SEs with MW 650, 664, and 678 Da occupied approximately 80% of the total content of SEs.  相似文献   

9.
The detection of trace aroma compounds in samples with complex matrices such as Chinese liquor (Baijiu) requires a combination of several methods, which makes the analysis process very complicated. Therefore, a headspace solid-phase microextraction (HS-SPME) method coupled with two-dimensional gas chromatography time-of-flight mass spectrometry (GC×GC-TOFMS) was developed for the quantitation of a large number of trace compounds in Baijiu. Optimization of extraction conditions via a series of experiments revealed that dilution of the alcohol content of 8 mL of Baijiu to 5%, followed by the addition of 3.0 g of NaCl and subsequent SPME extraction with DVB/CAR/PDMS fiber coating over 45 min at 45 °C was the most suitable. To check the matrix effects, various model Baijiu matrices were investigated in detail. The quantitative method was established through an optimized model synthetic solution, which can identify 119 aroma compounds (esters, alcohols, fatty acids, aldehydes and ketones, furans, pyrazines, sulfur compounds, phenols, terpenes, and lactones) in the Baijiu sample. The developed procedure provided high recovery (86.79–117.94%), good repeatability (relative standard deviation < 9.93%), high linearity (R2 > 0.99), and lower detection limits than reported methods. The method was successfully applied to study the composition of volatile compounds in different types of Baijiu. This research indicated that the optimized HS-SPME–GC×GC-TOFMS method was a valid and accurate procedure for the simultaneous determination of different types of trace compounds in Baijiu. This developed method will allow an improved analysis of other samples with complex matrices.  相似文献   

10.
We developed a method for determination of imidacloprid and its metabolites 5-hydroxy imidacloprid, olefin imidacloprid, imidacloprid urea and 6-chloronicotinic acid in Procambarus clarkii (crayfish) tissues using quick, easy, cheap, effective, rugged, and safe (QuEChERS) and high-performance liquid chromatography-triple quadrupole mass spectrometry. Samples (plasma, cephalothorax, hepatopancrea, gill, intestine, and muscle) were extracted with acetonitrile containing 0.1% acetic acid and cleaned up using a neutral alumina column containing a primary secondary amine. The prepared samples were separated using reverse phase chromatography and scanned in the positive and negative ion multiple reaction-monitoring modes. Under the optimum experimental conditions, spiked recoveries for these compounds in P. clarkii samples ranged from 80.6 to 112.7% with relative standard deviations of 4.2 to 12.6%. The limits of detection were 0.02–0.5 μg·L−1, the limits of quantification were 0.05–2.0 μg·L−1 and the method of quantification was 0.05–2.0 μg·kg−1. The method is rapid, simple, sensitive and suitable for rapid determination and analysis of imidacloprid and its metabolites in P. clarkii tissues.  相似文献   

11.
Two cheap, simple and reproducible methods for the electrophoretic determination of homocysteine thiolactone (HTL) in human urine have been developed and validated. The first method utilizes off-line single drop microextraction (SDME), whereas the second one uses off-line SDME in combination with field amplified sample injection (FASI). The off-line SDME protocol consists of the following steps: urine dilution with 0.2 mol/L, pH 8.2 phosphate buffer (1:2, v/v), chloroform addition, drop formation and extraction of HTL. The pre-concentration of HTL inside a separation capillary was performed by FASI. For sample separation, the 0.1 mol/L pH 4.75 phosphate buffer served as the background electrolyte, and HTL was detected at 240 nm. A standard fused-silica capillary (effective length 55.5 cm, 75 μm id) and a separation voltage of 21 kV (~99 μA) were used. Electrophoretic separation was completed within 7 min, whereas the LOD and LOQ for HTL were 0.04 and 0.1 μmol/L urine, respectively. The calibration curve in urine was linear in the range of 0.1–0.5 μmol/L, with R2 = 0.9991. The relative standard deviation of the points of the calibration curve varied from 2.4% to 14.9%. The intra- and inter-day precision and recovery were 6.4–10.2% (average 6.0% and 6.7%) and 94.9–102.7% (average 99.7% and 99.5%), respectively. The analytical procedure was successfully applied to the analysis of spiked urine samples obtained from apparently healthy volunteers.  相似文献   

12.
A sensitive method for the simultaneous analysis of five estrogens in sewage sludge was developed. The extraction and purification steps were optimized and the matrix effects were evaluated. The chromatographic gradient was optimized to limit matrix effects and the analysis step was performed by LC-MS/MS. The method consists of an ASE® extraction with a solvent mixture water/methanol 80/20?v/v at 100?°C followed by two consecutive purifications on Oasis HLB® and florisil cartridges. A thorough validation of the developed method was performed. Recoveries determined at two different spiking levels ranged between 86% and 126% depending on the molecule. Repeatability was evaluated on five replicates of the same sludge sample spiked at two different levels and measuring native estrogens in triplicates of 12 sludge samples. Relative standard deviations obtained a range of between 2% and 27%. Reproducibility was also studied by analyzing the same sludge on four different days: the relative standard deviation ranged between 14% and 20% for E1, βE2 and E3. For αE2, poor reproducibility (68%) was observed but it was linked to the very low quantity of αE2 present in the sludge sample and not to the method performance. The specificity of the method was evaluated on various sludge samples spiked at different spiking levels showing that performances of the proposed method were not modified by matrix effects. Finally, sensitivity of the method was evaluated taking into account both instrumental sensitivity and matrices; the estimated limits of quantification were around 1 ng/g for E1, between 2 and 4 ng/g for αE2, βE2, and E3 and around 5 ng/g for EE2.  相似文献   

13.
An analytical method for extraction and quantitative determination of amygdalin, prunasin, and sambunigrin in plant material is described. The method is based on extraction with high-power ultrasound (UAE), with acidified water as solvent and quantification by HPLC–DAD. The best extraction conditions were: 80% sonication amplitude, 55 s extraction time, 70% duty cycle, 0.1 g sample mass, and 10 mL acidified water (0.1% perchloric acid). Once developed, the method was validated in terms of accuracy and precision. Good linearity was obtained, with correlation coefficients exceeding 0.999 and the quantification limits ranged from 2.2 μg/g (amygdalin) to 9.6 μg/g (sambunigrin). The accuracy (recovery study) ranged between 90 and 104% and the reproducibility of the method was always <2.3% (RSD). Special attention should be paid to the ratio sample/solvent in samples with potential β-glucosidase activity to avoid degradation of the cyanogenic glycosides (CNGs). The proposed method was used to evaluate the content of CNGs in kernels of Prunus genera, apple seeds, apple pomace, and different plant materials of Sambucus nigra.  相似文献   

14.
Current methods for measuring the abundance of proteogenic amino acids in plants require derivatisation, extended run times, very sensitive pH adjustments of the protein hydrolysates, and the use of buffers in the chromatographic phases. Here, we describe a fast liquid chromatography–mass spectrometry (LC–MS) method for the determination of amino acids that requires only three steps: hydrolysis, neutralisation, and sample dilution with a borate buffer solution for pH and retention time stability. The method shows excellent repeatability (repeated consecutive injections) and reproducibility (repeated hydrolysis) in the amino acid content, peak area, and retention time for all the standard amino acids. The chromatographic run time is 20 min with a reproducibility and repeatability of <1% for the retention time and <11% for the peak area of the BSA and quality control (QC) lentil samples. The reproducibility of the total protein levels in the hydrolysis batches 1–4 was <12% for the BSA and the lentil samples. The level of detection on column was below 0.1 µM for most amino acids (mean 0.017 µM).  相似文献   

15.
Sludge generated after washing of fruits and vegetables during agro-food processes is a complex matrix and selective methods for the identification and quantification of pesticides’ residues are necessary in order to achieve a sustainable and effective management of the total sewage. The present work describes the development and validation of a reliable, simple and fast analytical method based on liquid chromatography-tandem mass spectrometry (LC-MS/MS) for the determination of 47 pesticides of different chemical classes, including organosphosphates, pyrethroids, neonicotinoids, triazoles and others, in sludge samples after QuEChERS sample preparation. The necessity of the individual steps of QuEChERS was investigated and the LC-ESI-MS/MS conditions were optimized to achieve maximum sensitivity of the target analytes. The method limits of detection (LODs) ranged between 0.0005 mg/kg (imidacloprid) and 0.05 mg/kg (beta cyfluthrin). The recoveries ranged between 71–120% and the repeatability of the method was ≤25% expressed as relative standard deviation. The method was applied to sludge samples generated after washing of fruits in an agro-fruit-packaging unit in Greece. The results showed the presence of 37 pesticides’ active substances with concentrations ranging from low ppbs, such as fludioxinil (5 μg/kg) up to low ppms such as beta cyfluthrin (3.5 mg/kg) and with their sum concentration reaching up to 19 mg/kg.  相似文献   

16.
The principal objective of this study was to develop an appropriate, sensitive, and selective method for the simultaneous quantitative determination of phoxim and its photo-transformation product, O,O-diethyl α-cyanobenzylideneamino-thiophosphonate (DCTP) in both chicken and quail eggs. Eggs (1 g) were blended with anhydrous magnesium sulfate (1 g) for sample pretreatment and extracted with acetonitrile. The extracts were then further purified with SPE silica gel tubes deactivated with trimethylamine. Residues were analyzed via a reversed phase-liquid chromatography-tandem mass spectrometry (RP-LC-MS/MS) in positive-ion electrospray ionization (ESI) mode. Tebufenozide was utilized as an internal standard for the quantification of phoxim and its metabolite residues. The identification and quantification of analytes were based on ion transitions monitored by multiple reaction monitoring (MRM). LC-MS/MS analysis was performed from 0.02 to 1 mg kg−1 and correlation coefficients (r2) ranging from 0.998 to 0.999 were obtained for both analytes in blank egg extracts. The relative standard deviations (RSDs) of intra- and inter-day variations ranged from 2.1% to 6.7% and from 2.8% to 6.4% for phoxim and DCTP in chicken and quail eggs. At all levels of fortification (0.02, 0.05, and 0.125 mg kg−1), the recoveries fell within a range of 81.3% to 93.6% for phoxim and 83.3% to 90.1% for DCTP. The matrix effect was <2%, due to the partial dilution of the sample. Decision limits (CCα) and detection capabilities (CCβ) were in the range of 0.0005-0.0044 and 0.0054-0.0224 mg kg−1, respectively. The method was evaluated further by analyzing real samples purchased from markets. All chicken and quail egg samples were free from residues of the target compounds.  相似文献   

17.
《Electrophoresis》2018,39(4):608-615
A sensitive method using CZE‐UV detection has been developed for the determination of five tetracycline antibiotics in human urine samples. To improve the sensitivity of the method, an on‐line preconcentration strategy, named field‐amplified sample injection, has been developed, based on the electrokinetic injection of the sample, which requires only a 1:100 dilution with sample solvent before injection. Under optimum conditions, sensitivity enhancement factors ranged from 450 to 800 for the studied compounds. The applicability of the proposed method was demonstrated by the determination of these antibiotics in spiked urine samples. The limits of quantification were lower than 0.8 mg/L and the precision (intra‐ and inter‐day), expressed as %RSD was below 14%. Recoveries ranged from 92.1 to 96.7%. Thus, the proposed procedure is a simple, fast and efficient strategy which could be used as therapeutic drug monitoring in human urine samples.  相似文献   

18.
The isotope dilution method is characterized by the use of appropiately labelled standard compounds in conjunction with mass spectrometry coupled to chromatographic systems. Although the isotope dilution method seems to be a simple procedure, some quality criteria for sample preparation, measurement and quantification have to be considered. Furthermore, archiving and documentation of analysis data as well as the use of reference materials to validate the analysis method are important with regard to European standard regulations for quality assurance. In view of this background and the increasing application tendency to environmental problems, essential quality critera for the isotope dilution method are presented and discussed, with special respect to sample extraction, separation performance and sensitivity. Also the quantification procedures are summarized.  相似文献   

19.
Turbidimetric method (TM), ion chromatography (IC) and inductively coupled plasma atomic emission spectrometry (ICP-AES) with and without acid digestion have been compared and validated for the determination of sulfate in mining wastewater. Analytical methods were chosen to compare the performance of a portable field turbidimetric instrument and to validate the underlying assumption utilized in conversion of total sulfur to sulfate during ICP-AES analysis. Accuracy and precision of analytical techniques were compared to one another using control and field samples collected from a mine site using the Bonferroni multiple comparison test. Effects of sample dilution, filter pore size and acidification on sulfate quantification were also studied. The results showed that IC and ICP-AES with and without acid digestion provided excellent recoveries in the case of control samples (within 90-110%). These analytical methods also showed lower relative standard deviation for both control and field samples. On the other hand, performance of the turbidimetric method was severely affected by sample dilution and acidification, and also revealed poor sulfate recoveries for control samples ranging from 0 to 83.5%. Analysis of variance (ANOVA) was used to evaluate the response (sulfate concentration) obtained from factorial design. Analytical method had significant effect (P < 0.0001) on the sulfate quantification. The interaction between determination method and sample dilution was more significant than other two-way interactions.  相似文献   

20.
The 2nd international interlaboratory study (ILS) on perfluorinated compounds (PFCs) in environmental samples was organized to assess the performance of 21 North American and European laboratories on the analysis of PFCs in water and fish. A study protocol was provided to assess accuracy, precision, matrix effects and to study the use of in-house standards. The participants used shared native and mass-labelled standards that were provided for this study to quantify the PFC concentrations in the samples. Matrix effects in the determination of PFCs can be considerable and can decrease the sensitivity, the accuracy and internal standard recoveries. Therefore, two quantification methods were evaluated by all laboratories: standard addition quantification (SAQ) and solvent-based calibration curve quantification (SBCCQ; using mass-labelled internal standards (IS)). The between laboratory reproducibility (i.e. coefficient of variance) was smaller for the SBCCQ results (except for PFBS and PFHxS for which no mass-labelled analogues were available) compared to those obtained by the SAQ method. The within laboratory precision of individual laboratories is good (mean for all PFCs in water 12% and 6.8% in fish). The good performance is partially attributable to the use of well-defined native- and mass-labelled standards. Therefore, the SBCCQ method is recommended. The results show that analytical methods for PFCs in water and fish have improved considerably. Critical steps identified in this study are (i) the use of well-defined native standards for quantification, (ii) the use of mass-labelled internal standards (preferably one for each target compound) and (iii) minimization of matrix effects by a better clean up.  相似文献   