首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
By gravimetric measurements using a quartz cristal microbalance (QCM), we have studied the immobilization of biotinylated glucose oxidase enzymes (B-GOx) bound through on an intermediate avidin layer to a biotinylated polypyrrole film. The aim is to assess the amount of B-GOx specifically anchored on the biotinylated polypyrrole/avidin assembly thank to the biotin/avidin interaction between avidin and B-GOx. Indeed the estimated amount from the QCM measurement corresponds to the specific recognition of avidin/B-GOx added to a non-specific recognition (adsorption) of B-GOx. In order to discriminate these two phenomena, we have carried out a study by QCM of the anchoring of B-GOx on an avidin layer linked by adsorption to a polypyrrole free from biotin units. From QCM measurements we have deduced for the biotinylated polypyrrole/avidin assembly that the amount of B-GOx bound via the biotin/avidin interaction and those due to the avidin adsorption process correspond to 3.9 pmol cm(-2) (1.3 equivalent of B-Gox monolayer) and 1.4 pmol cm(-2) (0.46 equivalent of B-GOx monolayer) respectively. These values have been corroborated by measurements of the enzymatic activity of GOx.  相似文献   

2.
The buildup of layer-by-layer assemblies onto gold surfaces from water-soluble charged polyelectrolytes and proteins is examined using quartz crystal microgravimetry (QCM) and electrochemical techniques. Polyelectrolytes such as poly(styrenesulfonate) and poly(ester sulfonic acid) (Eastman AQ-29D polymer) adsorb spontaneously onto gold, contrary to poly(ethyleneimine). From the modification of the gold surface with a thiol and specific adsorption of polymers under polarization conditions, it is concluded that the hydrophobicity of the gold surface seems to be a determining factor in the adsorption process. Alternate adsorption onto gold resonators first coated with AQ-29D polymer gives stable multilayer films in the case of positively charged lysozyme (pI = 11) or polyheme Desulfovibrio vulgaris Hildenborough cytochrome c3 (pI = 10.5). QCM frequency changes with the number of adsorption steps suggest that a linear increase in film mass occurs. Desulfomicrobium norvegicum polyheme cytochrome c3 (pI = 7), which has a null global charge at neutral pH, is shown to give also stable multilayer AQ-29D/cytochrome c3 films, suggesting that several types of interactions, especially the hydrophobic effect, are involved in the buildup process.  相似文献   

3.
无标记DNA在氨基改性导电聚吡咯表面的固定/杂交   总被引:1,自引:0,他引:1  
通过吡咯(Py)与其衍生物——6-吡咯己胺(PyHA)的共聚物聚(吡咯-co-6-吡咯己胺)[poly(Py-co-PyHA)]的合成研究,并采用电化学循环伏安法来考察体系的电化学活性.在缓冲溶液中,由于探针DNA链上的负电荷与共聚物分子链上的正电荷之间存在强烈的静电吸引力,使得DNA能够固定在导电聚合物膜上.实验结果证明,目标DNA和聚吡咯薄膜之间不存在非特异性吸附,而能和探针DNA进行顺利杂交.此结果为以后研究更为敏感的DNA固定及导电聚合物敏感膜提供了实验基础.  相似文献   

4.
Lassalle N  Roget A  Livache T  Mailley P  Vieil E 《Talanta》2001,55(5):993-1004
Conducting polymer films, such as polypyrrole, appear particularly attractive for the immobilisation of biological molecules by entrapment or covalent grafting. We describe here a new pyrrole phosphorarnidite building block allowing the synthesis of oligonucleotide (ODN) bearing a pyrrole moiety. The electropolymerisable pyrrole moiety was then introduced on the 5' end of the oligonucleotide. The electrosynthesis of a copolymer, from solutions containing pyrrole and pyrrole-ODN, gives in one step strongly adhesive films containing ODN probes at electrode surfaces. In this contribution, we have used such a methodology to verify its feasibility for the modification of quartz crystal microbalance (QCM) electrodes. The obtained biosensors enable the detection of DNA hybridisation in real time by micro-gravimetric transduction. Finally, as DNA targets were previously modified by biotin, we have used the affinity between biotin and avidin to validate the effectiveness of QCM transduction by fluorescence microscopy and to amplify the recorded micro-gravimetric signal.  相似文献   

5.
The kinetics of growth of polypyrrole films deposited onto electrode surfaces from aqueous solutions of pyrrole have been investigated. The rate-determining step for the growth of the film is the oxidation of pyrrole units or oligomers and their incorporation at the end of polymer chains. In spite of the positive potential imposed on the electrode during electrodeposition, polypyrrole remains essentially in its neutral state during growth and exhibits conductivities which are several orders of magnitude lower than those of already grown films. It is shown that the rate of film growth is limited by the low conductivity of the growing film, which was evaluated from potentiostatic current transients recorded during electrodeposition of polypyrrole.  相似文献   

6.
We demonstrate herein a newly developed photoelectrochemical immunosensor for the determination of anti-cholera toxin antibody by using a photosensitive biotinylated polypyrrole film. The latter was generated by electro-oxidation of a biotinylated tris(bipyridyl) ruthenium(II) complex bearing pyrrole groups. The photoexcitation of this modified electrode potentiostated at 0.5 V vs SCE, in the presence of an oxidative quencher, pentaaminechloro cobalt(III) chloride (15 mM), led to a cathodic photocurrent. As a result of the affinity interactions, a layer of biotinylated cholera toxin was firmly bound to the functionalized polypyrrole film via avidin bridges. The resulting modified electrodes were tested as immunosensors for the detection of the corresponding antibody from 0 to 200 microg mL(-)(1). The antibody concentration was measured through the decrease in photocurrent intensity resulting from its specific binding onto the polymeric coating, the detection limit being 0.5 microg mL(-)(1).  相似文献   

7.
This study concerns the design of protein-resistant polymer adsorbed layers for the control of surface binding of biospecific recognition entities. Polymer surface layers were prepared using the adsorption of poly(allylamine hydrochloride) (PAH), poly(l-lysine) (PL), and branched and linear polyethyleneimine (PEI) and further modified by the covalent attachment of biotin for specific avidin attachment. The adsorption of PAH, PL, and PEI on silicon substrates was studied as a function of pH and ionic strength using ellipsometry. Average dry layer thicknesses of approximately 10, approximately 5, approximately 9, and approximately 3 A (+/-1 A) were obtained when polymer adsorption occurred from solutions at pH 9.5 that contained 0.5 M NaCl for PAH, PL, branched PEI, and linear PEI, respectively. These polymers showed significant differences in their efficiency to suppress nonspecific avidin adsorption. At low ionic strength, avidin adsorption occurred on all polymer-coated surfaces at basic pH values, despite the same positive electrostatic charge for protein globules and the surface. Though the net electrostatic repulsion between avidin molecules and branched PEI was efficiently screened in a protein solution of pH 7 and 0.15 M NaCl, branched-PEI coatings of high molecular weight were unique in their ability to provide avidin-resistant surfaces as a result of steric hindrance from the branched architecture of adsorbed polymer chains. All polymers studied were effective in suppressing avidin adsorption at pH 3 as a result of protonation of the avidin surface functional groups at this pH. Branched-PEI-coated surfaces were also effective for the suppression of smaller positively charged proteins such as lysozyme and ribonuclease A at pH 7 and 0.15 M NaCl. They were also resistant to the adsorption of negatively charged proteins such as BSA and fibrinogen at pH 7 and 0.75 M NaCl. Furthermore, by using PEI-modified protein-repellent surfaces, selective binding of avidin was achieved to surface-bound silver nanoparticles, which should provide a promising application for the label-free detection of biological species using surface-enhanced Raman scattering (SERS).  相似文献   

8.
A critical requirement toward the clinical use of nanocarriers in drug delivery applications is the development of optimal biointerfacial engineering procedures designed to resist biologically nonspecific adsorption events. Minimization of opsonization increases blood residence time and improves the ability to target solid tumors. We report the electrostatic self-assembly of polyethyleneimine-polyethylene glycol (PEI-PEG) copolymers onto porous silica nanoparticles. PEI-PEG copolymers were synthesized and their adsorption by self-assembly onto silica surfaces were investigated to achieve a better understanding of structure-activity relationships. Quartz-crystal microbalance (QCM) study confirmed the rapid and stable adsorption of the copolymers onto silica-coated QCM sensors driven by strong electrostatic interactions. XPS and FT-IR spectroscopy were used to analyze the coated surfaces, which indicated the presence of dense PEG layers on the silica nanoparticles. Dynamic light scattering was used to optimize the coating procedure. Monodisperse dispersions of the PEGylated nanoparticles were obtained in high yields and the thin PEG layers provided excellent colloidal stability. In vitro protein adsorption tests using 5% serum demonstrated the ability of the self-assembled copolymer layers to resist biologically nonspecific fouling and to prevent aggregation of the nanoparticles in physiological environments. These results demonstrate that the electrostatic self-assembly of PEG copolymers onto silica nanoparticles used as drug nanocarriers is a robust and efficient procedure, providing excellent control of their biointerfacial properties.  相似文献   

9.
采用电子活化再生原子转移自由基聚合(AGET ATRP)的方法将聚(甲基丙烯酸-2-羟乙酯)(PHEMA)接枝在金表面,对经修饰的金表面的生物惰性做了系统的研究,并利用PHEMA的羟基末端固定生物素(biotin)分子,以biotin对抗生物素蛋白(avidin)的识别为模型,研究了不同厚度的PHEMA对结合avidin的影响,以及该表面作为生物检测基材的可行性.生物惰性研究表明,PHEMA修饰的金表面不但能够有效的排斥纤维蛋白原(Fg)、人血清白蛋白(HSA)和溶菌酶(Lys)的非特异性吸附,还能够抑制3种细胞(L02、L929和EC)的黏附,是一种良好的抗污表面.通过控制聚合时间制备了不同厚度的PHEMA-biotin修饰的表面,同位素125I标记HSA吸附结果表明这几种表面均能够有效排斥非特异性蛋白质吸附,特异性FITC-avidin吸附结果表明,厚度较小时(16 nm)由于荧光淬灭而难以检测到荧光信号,厚度在16 nm和49 nm之间,荧光信号随厚度增加而增强,通过比较信噪比,认为厚度在49 nm以上时比较理想.该表面在应用于QCM与荧光检测中均表现出良好的检测性能.  相似文献   

10.
《Electroanalysis》2003,15(3):225-229
The interaction between avidin and biotin was evaluated electrochemically by monitoring the change in the electrode response of redox markers. Biotin was immobilized on the electrode surface by means of the electrochemical polymerization of biotinylated pyrrole and pyrrole. When avidin was introduced onto the biotinylated polypyrrole electrode surface, the large change in the electrode response of the redox marker was detected. The fact that the change in the electrode response of a marker ion could be attributed to the electrostatic interaction between avidin on the electrode surface and the redox marker ion present in a solution was verified by replacing avidin with NutrAvidin. At a pH lower than the isoelectric point of avidin, the electrode response of ferrocyanide as an anionic marker ion increased linearly within the range of 5.0×10?9 ?3.0×10?8 M avidin. The relative standard deviation at 1.5×10?8 M avidin was about 5.4% (n=5). The detection of biotin was also performed using a competitive reaction between biotin in solution and biotin that had been immobilized on the electrode surface in the form of the biotinylated polypyrrole.  相似文献   

11.
Pejcic B  Myers M  Ranwala N  Boyd L  Baker M  Ross A 《Talanta》2011,85(3):1648-1657
This report compares the performance of polymer and carbon nanotube-polymer composite membranes on a quartz crystal microbalance (QCM) sensor for the detection of aromatic hydrocarbons (benzene, toluene, ethylbenzene, p-xylene and naphthalene) in aqueous solutions. Several different polymers (polystyrene, polystyrene-co-butadiene, polyisobutylene and polybutadiene) and types of functionalized carbon nanotubes (multi-walled and single-walled carbon nanotubes) were investigated at varying carbon nanotube (CNT) loading levels and film thicknesses. In a majority of instances, the difference in response between membranes comprising pure polymer and membranes containing 10% (w/w) carbon nanotubes were not statistically significant. However, a notable exception is the decreasing sensitivity towards p-xylene with increasing carbon nanotube content in a polybutadiene film. This variation in sensitivity can be attributed to a change in the sorption mechanism from absorption into the polymer phase to adsorption onto the carbon nanotube sidewalls. With much thicker coatings of 10% (w/w) carbon nanotube in polybutadiene, the sensitivity towards toluene was higher compared to the pure polymer. The increased toluene sensitivity may be partially attributed to an increase in the sorption capacity of a carbon nanotube polymer composite film relative to its corresponding pure polymer film. Attenuated total reflectance Fourier transform infrared spectroscopy (ATR-FTIR) measurements were performed to understand the mechanism of sorption and these studies showed that the addition of functionalized CNT to the polymer increases the absorption of certain types of hydrocarbons. This study demonstrates that carbon nanotubes can be incorporated into a polymer-coated QCM sensor and that composite films may be used to modify the QCM response and selectivity during the analysis of complex hydrocarbon mixtures.  相似文献   

12.
Stereoregular poly(methyl methacrylate)s (PMMAs) were stepwise assembled on a quartz crystal microbalance (QCM) substrate after the immersion of the QCM into alternating acetonitrile solutions at ambient temperature. A quantitative QCM analysis at each step showed stereocomplex formation on the substrate surface. The adsorption of bovine serum albumin (BSA) onto stereocomplex films with a molecularly regulated nanostructure was analyzed quantitatively. The adsorption constant and the maximum adsorption amount, calculated by the assumption of Langmuir‐type adsorption, showed that BSA adsorbed with a relatively weak interaction onto the stereocomplex films. The BSA adsorption onto the stereocomplex films occurred in an end‐on manner, with a smaller adsorption constant than for that onto individual spin‐coated films. The amount of BSA adsorbed was significantly affected by the molecular weight of syndiotactic PMMA. Attenuated total reflection spectra indicated that BSA adsorbed onto the films with or without denaturing. © 2003 Wiley Periodicals, Inc. J Polym Sci Part A: Polym Chem 41: 1807–1812, 2003  相似文献   

13.
The interaction of proteins with semiconductors such as silicon and diamond is of great interest for applications such as electronic biosensing. We have investigated the use of covalently bound oligo(ethylene glycol), EG, monolayers on diamond and silicon to minimize nonspecific protein adsorption. Protein adsorption was monitored by fluorescence scanning as a function of the length of the ethylene glycol chain (EG3 through EG6) and the terminal functional group (methyl- versus hydroxyl-terminated EG3 monolayer). More quantitative measurements were made by eluting adsorbed avidin from the surface and measuring the intensity of fluorescence in the solution. The attachment chemistry of the tri(ethylene glycol) molecules and monolayer orientation was studied by X-ray photoelectron spectroscopy. Improvement in the selectivity of surfaces modified with EG functionality was demonstrated in two model biosensing assays. We find that high-quality EG monolayers are formed on silicon and diamond and that these EG3 monolayers are as effective as EG3 self-assembled monolayers on gold at resisting nonspecific avidin adsorption. These results show promise for use of silicon and diamond materials in many potential applications such as biosensing and medical implants.  相似文献   

14.
Molecular imprinted polymer coated QCM for the detection of nandrolone   总被引:3,自引:0,他引:3  
An acoustic wave sensor coated with an artificial biomimetic recognition element has been developed to selectively screen for nandrolone in the liquid phase. A highly specific covalently imprinted polymer (MIP) was spin coated onto one electrode of a quartz crystal microbalance (QCM) as a thin permeable film. Selective rebinding of the nandrolone was observed as a frequency shift in the QCM for concentrations up to 0.2 ppm with the sensor binding shown to favour nandrolone over analogous compounds.  相似文献   

15.
For a number of potential applications, it is desirable to immobilize avidin class molecules onto solid supports and exploit their ability to bind biotinylated molecules with high affinity. NeutrAvidin molecules were surface immobilized in various ways. In this study, NeutrAvidin was covalently attached by carbodiimide chemistry onto carboxyl groups of polyacrylic acid and carboxymethyl-dextran hydrogel interlayers. A third strategy involved the affinity "docking" of NeutrAvidin onto a biotinylated poly(ethylene glycol) interlayer. These three interlayers were selected for their low nonspecific binding of proteins, which was expected to minimize surface binding of NeutrAvidin by nonspecific interfacial adsorption. X-ray photoelectron spectroscopy (XPS) analyses allowed detailed characterization of the multilayer fabrication steps. An ELISA assay was used to measure NeutrAvidin activity, which varied with the surface immobilization route. Atomic force microcopy (AFM) force measurements showed that the hydrogel interlayer contributed to a repulsive force and verified the specific interaction between biotinylated AFM tips and the NeutrAvidin surfaces. When a solution of free biotin was injected into the AFM liquid cell, the force curve changed substantially and became identical to that recorded between surfaces carrying no NeutrAvidin, indicating that the free solution biotin had displaced NeutrAvidin proteins off the PEG-biotin layer.  相似文献   

16.
The interaction of avidin with biotin was studied on functionalized quartz surfaces terminated with 3-aminopropyltrimethoxysilane (3-APTMS), 2,2'-(ethylenedioxy)bis(ethylenediamine) (DADOO), and fourth-generation amine-terminated polyamidoamine (G4-NH2 PAMAM) dendrimers with the use of Fourier transform infrared reflection-absorption spectroscopy (FT-IRRAS). In particular, the molecular recognition ability of these surfaces was quantified through FT-IRRAS in combination with the use of an alkyne dicobalt hexacarbonyl probe coupled with avidin. The degree of nonspecific adsorption of avidin was determined by exposure of the amine-terminated and/or biotinylated surfaces to solutions of biotin-saturated avidin. The results indicate that the biotinylated 3-APTMS layer exhibits a very low specific binding capacity for avidin (on the order of 0.15 pmol of avidin/cm2) and substantial nonspecific adsorption. Both the binding capacity and the specificity were greatly improved when the 3-APTMS layer on quartz was modified through serial chemisorption of glutaraldehyde (GA), DADOO, and/or G4-NH2 PAMAM dendrimer layers. Among these layers, the biotinylated G4-NH2 PAMAM dendrimer layer exhibited the highest capacity for avidin binding (2.02 pmol of avidin/cm2) with a specificity of approximately 90%. This effect can be attributed to the efficient packing/ordering of the binding dendrimer layer, leading to a more dense and better organized layer of biotin headgroups on the subsequent biotinylated surface.  相似文献   

17.
Polymer-based biomedical devices are growing increasingly sophisticated as compositions evolve toward copolymers and blends in order to satisfy complex design criteria. Such polymers afford opportunities for both micro- and macrophase separation at nano- and micro-length scales and raise questions concerning the role of heterogeneous surface morphology on protein adsorption. Adsorbed protein layers play a critical role in mediating the interaction of cells with polymer surfaces, and both understanding and controlling protein adsorption is assuming greater significance in the development of surfaces with enhanced physiological compatibility. Here we study the short-time adsorption of ferritin, a model protein highly resistant to denaturation and easily imaged in the transmission electron microscope (TEM), onto a phase-separated homopolymer blend of polycaprolactone (PCL) and a polycarbonate derived from desaminotyrosyl-tyrosine dodecyl ester (PDTD). At physiological pH, ferritin selectively adsorbs onto the PDTD phase at a surface density approximately three times greater than that on the PCL phase. By decreasing the pH below ferritin's isoelectric point so its average charge becomes positive, the selective adsorption disappears and the surface density of adsorbed ferritin becomes independent of the phase separation. We attribute the selectivity to the electrostatic repulsion between ferritin and hydrolytically charged PCL, both of which will have a net negative charge at physiological pH. To perform these experiments, we solvent-cast ultrathin polymer films onto dissolvable salt substrates, and we characterize the morphology by TEM imaging and quantitative spatially resolved electron energy-loss spectroscopy (EELS). We find that the film morphology depends strongly on such processing-related variables as the solvent evaporation rate and the nature of the surface in contact with the polymer film during casting. The adsorption of ferritin depends on whether the film is phase-separated as well as to which surface of the film the protein solution is exposed, and these findings suggest that seemingly small variations in polymer processing that influence both the bulk and surface morphology can have a profound effect on the short-time protein adsorption.  相似文献   

18.
19.
Coatings based on dendritic polyglycerol (dPG) were investigated for their use to control nonspecific protein adsorption in an assay targeted to analyze concentrations of a specific protein. We demonstrate that coating of the sample vial with dPG can significantly increase the recovery of an antibody after incubation. First, we determine the concentration dependent loss of an antibody due to nonspecific adsorption to glass via quartz crystal microbalance (QCM). Complementary to the QCM measurements, we applied the same antibody as analyte in an surface plasmon resonance (SPR) assay to determine the loss of analyte due to nonspecific adsorption to the sample vial. For this purpose, we used two different coatings based on dPG. For the first coating, which served as a matrix for the SPR sensor, carboxyl groups were incorporated into dPG as well as a dithiolane moiety enabling covalent immobilization to the gold sensor surface. This SPR-matrix exhibited excellent protein resistant properties and allowed the immobilization of amyloid peptides via amide bond formation. The second coating which was intended to prevent nonspecific adsorption to glass vials comprised a silyl moiety that allowed covalent grafting to glass. For demonstrating the impact of the vial coating on the accuracy of an SPR assay, we immobilized amyloid beta (Aβ) 1-40 and used an anti-Aβ 1-40 antibody as analyte. Alternate injection of analyte into the flow cell of the SPR device from uncoated and coated vials, respectively gave us the relative signal loss (1 − RUuncoated/RUcoated) caused by the nonspecific adsorption. We found that the relative signal loss increases with decreasing analyte concentration. The SPR data correlate well with concentration dependent non-specific adsorption experiments of the analyte to glass surfaces performed with QCM. Our measurements show that rendering both the sample vial and the sensor surface is crucial for accurate results in protein assays.  相似文献   

20.
Fourier transform surface plasmon resonance (FT-SPR) was utilized to study specific and non-specific interactions between proteins and a biotinylated polymer film by monitoring adsorptions of streptavidin (SAv) and bovine serum albumin (BSA) on the polymer films. The biotinylated polymer, poly(lactide-co-2,2-dihydroxymethyl-propylene carbonate-graft-biotin) [P(LA-co-DHC/biotin)], was prepared by ring-opening copolymerization of lactide and a OH-bearing cyclic carbonate monomer, followed by biotinylation of the OH groups. The copolymer was coated onto the FT-SPR chip and vacuum-dried, hydrated at 70°C, and treated with a blocking agent respectively to achieve different surface status. The FT-SPR results showed that the vacuum-dried film had the most BSA adsorption; hydration treatment led to migration of the biotin moieties from inner film to surface and thus resulted in less BSA adsorption; blocking layer on the polymer surface saturated the active sites for physical and chemical adsorptions on the surface and thus weakened the BSA adsorption. Adsorption of SAv displayed similar polymer-surface-status dependence, i.e., more adsorption on vacuum-dried surface, less adsorption on hydrated surface and the least adsorption on blocked surface. Compared with BSA, SAv showed more enhanced adsorptions on P(LA-co-DHC/biotin) surface because of the specific interaction of biotin moieties in the polymer with SAv molecules, especially on the blocked surface. The above semi-quantified results further indicate that the FT-SPR system is suitable for investigating interactions between polymer surface and bio-molecules.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号