A self‐assembled monolayer (SAM) modified by 4‐formylphenylboronic acid was formed on the gold electrode, which was applied for the determination of trace concentrations of Cu(II). The formation of advanced SAM on the gold electrode was evidenced by electrochemical impedance spectroscopy, atomic force microscopy and contact angle measurements. Electrochemical determination of Cu(II) ions was performed by square wave voltammetry. Some mutual interferences caused by Cd(II), Co(II), Fe(II), Ni(II) and Pb(II) ions were investigated and it was demonstrated how the negative effects of these interfering ions could be eliminated by adjustment of proper parameters of square wave voltammetry.  相似文献   

2.
《Analytical letters》2012,45(9):1807-1820
ABSTRACT

5-amino-1,3,4-thiadiazole-2-thiol groups attached on a silica gel surface have been used for adsorption of Cd(II), Co(II), Cu(II), Fe(III), Ni(II), Pb(II) and Zn(II) from aqueous solutions. The adsorption capacities for each metal ion were (in mmol.g?1): Cd(II)= 0.35, Co(II)= 0.10, Cu(II)= 0.15, Fe(III)= 0.20, Hg(II)= 0.46, Ni(II)= 0.16, Pb(II)= 0.13 and Zn(II)= 0.15. The modified silica gel was applied in the preconcentration and quantification of trace level metal ions present in water samples (river, and bog water).  相似文献   

3.
Wei Y  Yang R  Yu XY  Wang L  Liu JH  Huang XJ 《The Analyst》2012,137(9):2183-2191
We have demonstrated highly selective and sensitive detection of Pb(II) and Cd(II) using a highly selective adsorptive porous magnesium oxide (MgO) nanoflowers. The MgO nanoflower-modified glassy carbon electrode was electrochemically characterized using cyclic voltammetry; and the anodic stripping voltammetric performance of bound Pb(II) and Cd(II) was evaluated using square wave anodic stripping voltammetry (SWASV) analysis. The MgO nanoflower-modified electrode exhibited excellent sensing performance toward Pb(II) and Cd(II) that was never observed previously at bismuth (Bi)-based electrodes. Simultaneous additions of Pb(II) and Cd(II) were investigated in the linear range from 3.3 to 22 nM for Pb(II) and 40 to 140 nM for Cd(II), and detection limits of 2.1 pM and 81 pM were obtained, respectively. Some foreign ions, such as Cu(II), Zn(II) and Cr(III) do not interfere with the detection of Pb(II) and Cd(II). To the best of our knowledge, this is the first example of a highly adsorptive metal oxide with hierarchical micro/nanostructure that allows the detection of both Pb(II) and Cd(II) ions.  相似文献   

4.
Cathodic stripping voltammetry of trace Mn(II) at carbon film electrodes   总被引:1,自引:0,他引:1  
Filipe OM  Brett CM 《Talanta》2003,61(5):643-650
A sensitive voltammetric method is presented for the determination of tract levels of Mn (II) using carbon film electrodes fabricated from carbon resistors of 2 Ω. Determination of manganese was made by square wave cathodic stripping voltammetry (CSV), with deposition of manganese as manganese dioxide. Chronoamperometric experiments were made to study MnO2 nucleation and growth. As a result, it was found to be necessary to perform electrode conditioning at a more positive potential to initiate MnO2 nucleation. Under optimised conditions the detection limit obtained was 4 nM and the relative standard deviation for eight measurements of 0.22 nM was 5.3%. Interferences from various metal ions on the response CSV of Mn(II) were investigated, namely Cd(II), Ni(II), Cu(II), Cr(VI), Pb(II), Zn(II) and Fe(II). Application to environmental samples was demonstrated.  相似文献   

5.
《Electroanalysis》2005,17(21):1970-1976
The oxidative electropolymerization of the (3‐pyrrol‐1‐ylpropyl)malonic acid monomer 1 is a simple and reproducible one‐step procedure for the synthesis of complexing polymer film modified electrodes, which have been applied to the electroanalysis of Cu(II), Pb(II), Cd(II) and Hg(II) ions by preconcentration upon complexation, followed by anodic stripping analysis. The detection limits were determined from square‐wave voltammetry at 0.5 nM, 5 nM, 50 nM and 0.2 μM for Pb(II), Cu(II), Hg(II) and Cd(II), respectively, after 10 min preconcentration. The modified electrodes showed a better selectivity toward copper(II) ions. Analysis of copper in a tap water sample agreed well with ICPMS analysis results.  相似文献   

6.
Davis J  Vaughan DH  Stirling D  Nei L  Compton RG 《Talanta》2002,57(6):318-1051
The exploitation of the Ni(III)/Ni(II) transition as a means of quantifying the concentration of nickel within industrial samples was assessed. The methodology relies upon the reagentless electrodeposition of Ni onto a glassy carbon electrode and the subsequent oxidative conversion of the metallic layer to Ni(III). The analytical signal is derived from a cathodic stripping protocol in which the reduction of the Ni(III) layer to Ni(II) is monitored through the use of square wave voltammetry. The procedure was refined through the introduction of an ultrasonic source which served to both enhance the deposition of nickel and to remove the nickel hydroxide layer that results from the measurement process. A well-defined stripping peak was observed at +0.7 V (vs. AgAgCl) with the response found to be linear over the range 50 nM to 1 μM (based on a 30 s deposition time). Other metal ions such as Cu(II), Mn(II), Cr(III), Pb(II), Cd(II), Zn(II), Fe(III) and Co(II) did not interfere with the response when present in hundred fold excess. The viability of the technique was evaluated through the determination of nickel within a commercial copper nickel alloy and validated through an independent comparison with a standard ICP-AES protocol.  相似文献   

7.
《Electroanalysis》2017,29(3):880-889
A new method for modifying electrodes with Ag nanoparticles (AgNPs) using electrospray deposition for sensitive, selective detection of Zn(II), Cd(II), and Pb(II) in aerosol samples when combined with Bismuth and Nafion coating and square‐wave anodic stripping voltammetry (SWASV) is reported. Carbon stencil‐printed electrodes (CSPEs) fabricated on a polyethylene transparency (PET) sheet were produced for an inexpensive, simple to fabricate, disposable sensor that can be used with the microliter sample volumes for analysis. Sensor performance was improved by modifying the electrode surface with electrospray‐deposited AgNPs. The use of electrospray deposition resulted in more uniform particle dispersion across the electrode surface when compared to drop‐casting. Using AgNP‐modified electrodes combined with Bi and Nafion, experimental detection limits (LODs) of 5.0, 0.5, and 0.1 μg L−1 for Zn(II), Cd(II), and Pb(II), respectively, were achieved. The linear working ranges were 5.0–400.0 μg L−1, 0.5–400.0 μg L−1, and 0.1–500.0 μg L−1 for Zn(II), Cd(II), and Pb(II), respectively. Interference studies showed Cu(II) was the only metal that interfered with this assay but inference could be eliminated with the addition of ferricyanide directly to the sample solution. This electrochemical sensor was applied for the simultaneous determination of Zn(II), Cd(II), and Pb(II) within source particulate matter (PM) samples collected on filters using an aerosol test chamber.  相似文献   

8.
Summary Based on high-pressure ashing, the potential to determine some trace metals (Zn, Cd, Pb, Cu, Ni, Co, Al, Tl, Cr, Fe) by anodic or cathodic stripping voltammetry in the square wave (SWV) and differential pulse modes (DPASV) is described. In comparison to the differential pulse mode, the square wave mode shows advantages for cathodic stripping and for zinc determination.New developments by use of potentiometric stripping analysis (PSA) permit the determination of Pb and Cd in whole blood without sample pretreatment and Pb, Cd, and Cu in milk and milk powder with simple pretreatment.Mercury film microelectrodes prepared by electrodeposition of Hg onto a carbon fiber were used for the rapid multicomponent trace determination of heavy metals in very small (5 l) samples by voltammetry and potentiometry.
Gegenwärtiges Potential elektrochemischer Methoden für Metallbestimmungen in Referenzmaterialien
  相似文献   

9.
The dynamic adsorption and desorption properties, including the effect of pH value and flow rate on the adsorption, eluent acidity and volume, eluting velocity and re-use, of Cu(II), Pb(II), Zn(II), Cd(II), Mn(II), Ni(II), Co(II) and Hg(II) ions on the column loaded with poly(acrylaminophosphonic-carboxyl-hydrazide) chelating fiber were investigated. The recovery of Mn(II), Co(II), Cd(II), Ni(II) and Zn(II) ions in the presence of Na, K, Ca and Mg ions was examined. The preconcentration of trace amounts of Mn(II), Co(II), Cd(II), Ni(II) and Zn(II) ions from model solution samples was carried out with satisfactory results. The amount of the metal ions detected after preconcentration and recovery by this technique was basically in agreement with the added amount. The method is rapid, precise and simple. Received: 15 October 1997 / Revised: 17 March 1998 / Accepted: 20 March 1998  相似文献   

10.
The dynamic adsorption and desorption properties, including the effect of pH value and flow rate on the adsorption, eluent acidity and volume, eluting velocity and re-use, of Cu(II), Pb(II), Zn(II), Cd(II), Mn(II), Ni(II), Co(II) and Hg(II) ions on the column loaded with poly(acrylaminophosphonic-carboxyl-hydrazide) chelating fiber were investigated. The recovery of Mn(II), Co(II), Cd(II), Ni(II) and Zn(II) ions in the presence of Na, K, Ca and Mg ions was examined. The preconcentration of trace amounts of Mn(II), Co(II), Cd(II), Ni(II) and Zn(II) ions from model solution samples was carried out with satisfactory results. The amount of the metal ions detected after preconcentration and recovery by this technique was basically in agreement with the added amount. The method is rapid, precise and simple. Received: 15 October 1997 / Revised: 17 March 1998 / Accepted: 20 March 1998  相似文献   

11.
Thiacalix[4]arenetetrasulfonate (TCAS) has been examined as a pre-column chelating reagent for the determination of trace metal ions by kinetic differentiation mode (KD) ion-pair reversed-phase high-performance liquid chromatography (HPLC) with spectrophotometric detection. Among 14 kinds of common metal ions tested here, viz. Al(III), Ca(II), Cd(II), Co(II), Cr(III), Cu(II), Fe(III), Hg(II), Mg(II), Mn(II), Ni(II), Pb(II), V(V), and Zn(II) ion, only Ni(II) ion was detected as the TCAS chelate in the HPLC separation stage in spite of TCAS forming the chelates with various metal ions except for Al(III), Ca(II), and Mg(II) at the pre-column chelation stage. The undetected metal-TCAS chelates seemed to be dissociated on an HPLC column where no added TCAS was present in the mobile phase because of their kinetic unstability. The calibration graph for Ni(II) ion gave a wide linear dynamic range (40-20,000 nM) with the very low detection limit (DL) (3σ base-line fluctuation) to be 5.4 nM (0.32 ng ml−1). The practical applicability of the KD-HPLC method with TCAS was demonstrated with the determination of trace Ni in coal fly ash.  相似文献   

12.
Here we investigate the use of 3D printed graphene/poly(lactic acid) (PLA) electrodes for quantifying trace amounts of Hg, Pb, and Cd. We prepared cylindrical electrodes by sealing a 600 μm diameter graphene/PLA filament in a pipette tip filled with epoxy. We characterized the electrodes using scanning electron microscopy, Raman spectroscopy, and cyclic voltammetry in ferrocene methanol. The physical characterization showed a significant amount of disorder in the carbon structure and the electrochemical characterization showed quasi‐reversible behavior without any electrode pretreatment. We then used unmodified graphene/PLA electrode to quantify Hg, and Pb and Cd in 0.01 M HCl and 0.1 M acetate buffer using square wave anodic stripping voltammetry. We were able to quantify Hg with a limit of detection (LOD) of 6.1 nM (1.2 ppb), but Pb and Cd did not present measurable peaks at concentrations below ~400 nM. We improved the LODs for Pb and Cd by depositing Bi microparticles on the graphene/PLA and, after optimization, achieved clear stripping peaks at the 20 nM level for both ions (4.1 and 2.2 ppb for Pb2+ and Cd2+, respectively). The results obtained for all three metals allowed quantification below the US Environmental Protection Agency action limits in drinking water.  相似文献   

13.
This work describes the development of an electrochemical sensor for simultaneous detection of Zn(II), Cd(II), and Pb(II) using a graphene–polyaniline (G/PANI) nanocomposite electrode prepared by reverse-phase polymerization in the presence of polyvinylpyrrolidone (PVP). Two substrate materials (plastic film and filter paper) and two nanocomposite deposition methods (drop-casting and electrospraying) were investigated. Square-wave anodic stripping voltammetry currents were higher for plastic vs. paper substrates. Performance of the G/PANI nanocomposites was characterized by scanning electron microscopy (SEM) and cyclic voltammetry. The G/PANI-modified electrode exhibited high electrochemical conductivity, producing a three-fold increase in anodic peak current (vs. the unmodified electrode). The G/PANI-modified electrode also showed evidence of increased surface area under SEM. Square-wave anodic stripping voltammetry was used to measure Zn(II), Cd(II), and Pb(II) in the presence of Bi(III). A linear working range of 1–300 μg L−1 was established between anodic current and metal ion concentration with detection limits (S/N = 3) of 1.0 μg L−1 for Zn(II), and 0.1 μg L−1 for both Cd(II) and Pb(II). The G/PANI-modified electrode allowed selective determination of the target metals in the presence of common metal interferences including Mn(II), Cu(II), Fe(III), Fe(II), Co(III), and Ni(II). Repeat assays on the same device demonstrated good reproducibility (%RSD < 11) over 10 serial runs. Finally, this system was utilized for determining Zn(II), Cd(II), and Pb(II) in human serum using the standard addition method.  相似文献   

14.
Dev K  Rao GN 《Talanta》1995,42(4):591-596
A polystyrene divinyl benzene based resin containing bicine groups has been prepared and its analytical properties investigated. The pH dependence of sorption of metal on the resin has been determined for Cu(II), Fe(II), Ni(II), Co(II), Zn(II), Hg(II) and Pb(II). The important characteristics of the resin are fast equilibrium, high selectivity and small volume change between its hydrogen and metal forms. These enable it to be applied to the rapid concentration of trace amounts of these metal ions. It shows promise for the separation of lead from other metal ions.  相似文献   

15.
Khater MM  Korkisch J 《Talanta》1971,18(10):1001-1004
The batch distribution coefficients of Cu(II), Za, Cd, Fe(III), Hg(II), Mg, Co(II), Ni, Pb, Ca and Bi were determined on the strongly acidic cation-exchange resin Dowex 50 x 8 in 0.1M trioctylphosphine oxide in tetrahydrofuran-5% 12M nitric acid. In this mixture all these metal ions, except Bi, have high K(d)-values and can be separated quantitatively from uranium which has a distribution coefficient of 0.1. Mixtures of U with Cu, Ni, Co, Cd or Fe were analysed to test the applicability of such separations. Different titrimetric and spectrophotometric methods were used to determine the elements subsequent to their separation from uranium on ion-exchange columns. The results show that accurate and effective separations can be achieved.  相似文献   

16.
In this work, a simple, rapid, reliable and low cost method for simultaneous electrochemical determination of As, Cu, Hg and Pb ions, on a vibrating gold microwire electrode combined with stripping voltammetry, is described for the first time.The multi-element detection was performed in the presence of oxygen by differential pulse anodic stripping voltammetry (DPASV) in HCl 0.1 M with NaCl 0.5 M. This media was found optimum in terms of peak resolution, peak shape and sensitivities, and has a composition similar to seawater to which the method could potentially be applied. The gold microwire electrode presented well defined, undistorted, sharp and reproducible peaks for trace concentrations of Cu, Hg and Pb and As presented a reproducible peak with a small shoulder. Using a gold vibrating microwire electrode of 25 μm diameter and 30 s deposition time, the detection limits of As, Cu, Hg and Pb were 0.07, 0.4, 0.07 and 0.2 μg L−1, respectively. Possible effects of Al, Cd, Cr, Fe, Mn, Ni, Sb and Zn were investigated but did not cause any significant interferences.Finally, the method was applied for the simultaneous determination of these four metals in unpolluted river water samples and the results were validated by Atomic Absorption Spectroscopy with Electrothermal Atomization (AAS-EA) or by Inductively Coupled Plasma Mass Spectrometry (ICP-MS).  相似文献   

17.
Pathak R  Rao GN 《Talanta》1997,44(8):1447-1453
A poly[styrene-co-(divinylbenzene)] resin (XAD-4) functionalized with 1-hydrazinophthalazine ligand has been prepared and its analytical properties investigated. The pH dependence of sorption of metal ion on the resin has been determined for Cu(II), Ni(II), Co(II), Zn(II), Cd(II), Pb(II), Fe(III) and Cr(III). Trace amounts of these metal ions were quantitatively retained on the resin and recovered by eluting with 1 mol l(-1) hydrochloric acid. The resin was found to be selective for Fe(III) and its separation from other metal ions was carried out effectively. Metal ions concentrations were determined using AAS.  相似文献   

18.
Dev K  Rao GN 《Talanta》1996,43(3):451-457
A polystyrenedivinylbenzene-based macroreticular resin was functionalised with bis-(N,N'-salicylidene)1,3-propanediamine ligands and its analytical properties have been investigated. The pH dependence of metal resin chelation has been determined for Cu(II), Ni(II), Co(II), Zn(II), Fe(II), Mn(II), Pb(II), Cd(II) and Cr(III). Trace amounts of these metal ions were quantitatively retained on the resin at neutral pH and easily recovered by elution with 1 N hydrochloric acid. The resin exhibits good chemical stability and fast equilibration with the metal ion making it useful for rapid concentration of trace amounts of metal ions on the resin columns.  相似文献   

19.
煤中痕量元素在循环流化床锅炉中的迁移行为与富集特性   总被引:2,自引:0,他引:2  
对天津市某电厂循环流化床(CFB)锅炉燃用的原煤及燃烧产物底灰、飞灰、细飞灰(≤50 μm)进行痕量元素含量的测定,分析了Be、Zn、Hg、V、Cr、Mn、Co、Ni、Cu、As、Se、Cd、Pb 13种痕量元素在燃烧过程中的迁移行为,揭示了痕量元素在CFB锅炉中的分配、富集特性。结果表明,CFB锅炉中,较低的炉温对于痕量元素的迁移富集产生了较大的影响。由相对富集系数得知,Be、V、Co、Se在底灰中耗散,在飞灰中富集,Zn、Mn倾向于在底灰中富集,元素Cd、Pb、Ni、Cu挥发性较强,在底灰和飞灰中均是耗散。As受钙氧化物影响,挥发性表现并不明显。Hg在底灰和飞灰中相对富集系数均很低,表明Hg在整个燃烧过程中以气态形式排放;Hg、As、Se、V、Cr、Mn、Co、Ni、Cu、Zn、Pb均有向小颗粒物中富集的趋势。根据相对富集系数以及研究的13种元素在低温CFB锅炉中的迁移行为,将这些元素分为三类:A类(ER<0.1),主要是以气态形式排放元素Hg;B类(0.1R≤0.85),较易挥发元素As、Be、Ni、Cu、Se、Cd、Pb、Co、V;C类(ER>0.85),主要残留在固体产物中元素Zn、Mn、Cr。  相似文献   

20.
In this work, simultaneous determination of Cu(II), Pb(II) and Zn(II) ions at low concentration levels (ppb) by square wave anodic stripping voltammetry on a Bi(III) film electrode plated in situ at a glassy carbon electrode (GCE) is described. A chemometric approach was used to overcome the overlapping peaks of Cu(II) and Bi(III), the competition of the electrodeposited Cu and Bi for the surface of the GCE and the formation of Cu‐Zn intermetallic compounds. The construction of the multivariate calibration models, based on partial least squares regression, allowed the simultaneous determination of Cu (in the concentration range 8.0 to 20.1 ppb), Pb (2.0 to 30.0 ppb) and Zn (29.7 to 90.4 ppb) with most of the prediction errors obtained in the external validation set for the three models lower than 16, 11 and 26 %, respectively. Finally, this method was used for the determination of these trace metal ions in surface river water samples with satisfactory results [errors below 10, 5 and 32 % for Cu(II), Pb(II) and Zn(II), respectively].  相似文献   