首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 578 毫秒
1.
Liu X  Tu Y  Zhao Y  Zhu L  Liu H  Yu H  Ding Y  Ren Y 《Talanta》1992,39(3):207-209
The catalytic polarographic determination of selenium(IV) by use of the SeSO(2-)(3) -KIO(3) system is sensitive, accurate, rapid and requires only small quantities of sample. The detection limit for selenium(IV) is 0.04 ng/ml in the final solution. The working range of the calibration is 0.04-2.5 ng/ml. Se(VI) present can be reduced with hot hydrochloric acid to Se(IV), allowing determination of the total selenium.  相似文献   

2.
Jiankuan Duan  Bin Hu  Man He 《Electrophoresis》2012,33(19-20):2953-2960
In this paper, a new method of nanometer‐sized alumina packed microcolumn SPE combined with field‐amplified sample stacking (FASS)–CE‐UV detection was developed for the speciation analysis of inorganic selenium in environmental water samples. Self‐synthesized nanometer‐sized alumina was packed in a microcolumn as the SPE adsorbent to retain Se(IV) and Se(VI) simultaneously at pH 6 and the retained inorganic selenium was eluted by concentrated ammonia. The eluent was used for FASS–CE–UV analysis after NH3 evaporation. The factors affecting the preconcentration of both Se(IV) and Se(VI) by SPE and FASS were studied and the optimal CE separation conditions for Se(IV) and Se(VI) were obtained. Under the optimal conditions, the LODs of 57 ng L?1 (Se(IV)) and 71 ng L?1 (Se(VI)) were obtained, respectively. The developed method was validated by the analysis of a certified reference material of GBW(E)080395 environmental water and the determined value was in a good agreement with the certified value. It was also successfully applied to the speciation analysis of inorganic selenium in environmental water samples, including Yangtze River water, spring water, and tap water.  相似文献   

3.
Safavi A  Mirzaee M 《Talanta》2000,51(2):225-230
A sensitive catalytic kinetic spectrofluorimetric method for determining ng ml(-1) of selenium by flow injection analysis has been developed. The method, based on the catalytic effect of Se (IV) on the reduction of resorufin by sulphide, in the presence of cetylpyridinium chloride, is monitored spectrofluorimetrically (lambda(ex)=480 nm; lambda(em)=583 nm). The linearity range of the calibration graph is dependent on the concentration of sulphide. The variables affecting the rate of the reaction were investigated. The method is simple, rapid, precise, sensitive, and widely applicable. The limit of detection is 1 ng ml(-1) Se (IV), and the calibration range is 5-1000 ng ml(-1). Sampling rate is 60 samples h(-1), and the relative standard deviation of 12 determinations of 100 ng ml(-1) Se was 0.76%. The determination of Se (IV) in the presence of Se (VI) and total selenium is described. The method was applied to the determination of Se in selenium tablets, and several synthetic samples.  相似文献   

4.
A simple, novel, and selective flow‐injection solid‐phase extraction with inductively coupled plasma optical emission spectrometry method was developed for the speciation of inorganic selenium in environmental water samples. A mesoporous zirconia film was simply introduced to coat coal cinder by means of the sol–gel technique, and the adsorptive performance of the coated material for Se(IV)/Se(VI) was investigated in different media. Both Se(IV) and Se(VI) can be retained quantitatively by the material in HCl/NaOH (pH 1.0–9.0) media, while only Se(IV) was adsorbed quantitatively in sodium acetate buffer (pH 3.5–6.0). Thus, the assay of Se(VI) is based on subtracting Se(IV) from total selenium by controlling different adsorptive media without employing any redox procedure. Under the optimum conditions, the detection limit of Se(IV) is 9.0 ng/L with an enrichment factor of 100, and the relative standard deviation is 3.6% (n = 9, C = 5.0 ng/mL). The developed method was successfully applied to the speciation of inorganic selenium in environmental water samples with satisfactory results. In order to further verify the accuracy of the developed method, it was applied to analysis of total selenium in GSBZ 50031–94 certified reference environmental water, and the determined values coincided with the certified values very well.  相似文献   

5.
Afkhami A  Madrakian T 《Talanta》2002,58(2):311-317
A simple, accurate, sensitive and selective method is described for rapid determination of ultra-trace quantities of selenium. Selenium (IV) was collected on activated carbon after reduction to elemental Se by l-ascorbic acid. The collected selenium was then determined based on its accelerating effect on the oxidation reaction of methyl orange with bromate in acidic media. Total amount of Se(IV) and Se(VI) were collected on AC after their reduction by hydrazine. Se(IV), Se(VI) and total selenium could be determined by the method. Selenium in the range 10-10 000 ng could be determined by the method. The method was used to the determination of Se(IV), Se(VI) and total selenium in natural water with satisfactory results.  相似文献   

6.
A sensitive catalytic method for determining ng ml? concentration of selenium is described. The method is based on the catalytic action of Se(IV) on the reduction of resazurin by sulphide, monitored spectrophotometrically at 605 nm. The linearity range of the calibration graph is dependent on the concentration of sulphide. The variables affecting the rate of the reaction were investigated and the optimum conditions were established. The method is simple, rapid, precise, sensitive and widely applicable. As low as 8.0 × 10?4 μg ml?1 of selenium can be determined. The relative standard deviation of seven determination of 10 ng Se was 0.7%. The determination of Se(IV) in the presence of Se(VI) and the determination of total selenium are also described.  相似文献   

7.
Neutron activation analysis using shortlived77mSe (T=17.5 s) preceded by chemical pre-collection of Se on activated carbon (AC) has been applied to the fractional determination of Se(IV) and Se(VI) in natural water samples such as river water and sea water. Two chemical procedures were adopted: adsorption of Se(IV)/Bismuthiol-II complex on AC and adsorption of Se(VI)/Bismuthiol-II on AC after reduction of Se(VI) to Se(IV). It was shown that Se(IV) and Se(VI) can be determined at a <g l–1 (ppb) level in natural waters by the present method.  相似文献   

8.
Afkhami A  Safavi A  Massoumi A 《Talanta》1992,39(8):993-996
A method is presented for the determination of selenium, based on the catalytic effect of selenium(IV) on the reduction reaction of BrO(-)(3) by N(2)H(4).2HCl. The decolourization of Methyl Orange by the reaction products was used to monitor the reaction spectrophotometrically at 525 nm. This method is precise, highly sensitive, simple, rapid, widely applicable and selective for the determination of selenium(IV) and total selenium. The variables which affected the reaction rate were fully investigated and the optimum conditions were established. Selenium, as low as 1 ng/ml, can be determined by this method. The relative standard deviation of 20 ng of selenium was 0.94% (N = 10). The method was applied to the determination of Se(IV) in a health-care product.  相似文献   

9.
A semi-automatic continuous method for the determination of Se(IV) based on flow-injection cathodic stripping voltammetry (FICSV) is reported. The flow injection approach incorporates a thin mercury film on glassy carbon as the working electrode, on which Se(IV) is deposited at an applied potential of 0.0 V. A cathodic scan (from 0.0 to –0.9 V) is applied and the Se is stripped at –0.54 V, providing a current intensity proportional to the Se(IV) concentration in the sample. This method features a linear determination range between 0.5 and 30 ng/ml (r2=0.998, RSD=3.6%). The non-interference levels (foreign species to analyte ratio) are 2.5:1 for Cu(II), 7.5:1 for Pb(II), 35:1 for Cd(II), 250:1 for Zn(II) and 500:1 for Fe(III). After developing the method for Se(IV), the speciation of this element has been performed by sequential injection of the dissolved sample into a carrier which may or may not have been previously reduced off-line thus determining the sum (Se(IV)+Se(VI)) or only Se(IV), respectively. The method has been applied to selenium speciation in water samples.  相似文献   

10.
A novel magnetic dispersive solid phase extraction method using magnetic multi-walled carbon nanotubes modified with 5-mercapto-3-phenyl-1,3,4-thiadiazole-2-thione potassium salt (bismuthiol II) (MMWCNTs@Bis) as the sorbent was developed for the separation and preconcentration of inorganic selenium (IV) prior to its determination by electrothermal atomic absorption spectrometry. The prepared MMWCNTs@Bis sorbent was characterised by Fourier transform infrared spectroscopy, scanning electron microscopy, vibrating sample magnetometer and X-ray diffraction. Total selenium was determined after reduction of Se(VI) to Se(IV) by addition of hydrochloric acid and heating the mixture in a boiling water bath. Se(VI) concentration was determined from the difference between the amounts of total selenium and Se(IV). Under the optimised experimental conditions, an enhancement factor of 196 and a detection limit (based on 3Sb/m) of 0.003 µg L?1 was obtained for aqueous samples. The relative standard deviation at 0.1 µg L?1 concentration level of Se(IV) (n = 6) was found to be 5.2 and 7.7% for intra- and inter-day analysis, respectively. The method was successfully applied to the determination of inorganic selenium species in water and total selenium in food samples.  相似文献   

11.
《中国化学快报》2022,33(7):3444-3450
A simple and convenient method has been developed for the pre-concentration and separation of inorganic selenium species from environmental water samples using anion exchange chromatographic column combined with high resolution inductively coupled plasma mass spectrometry (HR-ICP-MS) measurement. 75Se(IV) and 75Se(VI) were prepared and used as tracers during the experiments. The volatility of selenium during solution evaporation was investigated to establish a reliable water samples pretreatment procedure. The parameters which affect the uptake of Se(IV) and Se(VI) on Dowex1 × 8 resin was optimized and the procedure for Se(IV) and Se(VI) separation was proposed. Both Se(IV) and Se(VI) are retained on the column in natural or alkaline solution with high distribution coefficient. The successive gradient elution of pre-concentrated species of selenium with HNO3 solution allows to differentiate between them. Se(IV) and Se(VI) finally were eluted with 0.05 mol/L HNO3 and 5.0 mol/L HNO3, respectively. The proposed method has been successfully verified using the certified reference materials (CRMs) of real water samples, and spiked recoveries for real samples were 98%-104% with 5% relative standard deviations (RSDs). The developed procedure is proved to be reliable and can be used for the rapid determination of selenium species in environmental water samples.  相似文献   

12.
A flow injection system has been developed consisting of on-line preconcentration of selenium species in a microcolumn filled with activated alumina, reduction of Se(VI) to Se(IV) and determination by HG-AAS. When 0.01 mol/L HNO3 is used both as carrier and activation reagent for the alumina microcolumn, up to 150 ng of Se(IV) and Se(VI) can be preconcentrated and quantitatively eluted by 500 L of 2 mol/L NH3. The preconcentration factor is 50 when 25 mL of sample is used. The detection limit is about 6 ng/L, the precision is 5% for low concentrations such as 150 ng/L and 3% at high concentrations such as 120 ng/mL. The proposed method is suitable for natural water samples and inorganic Se speciation can be performed by determining Se(IV) and total selenium [Se(VI) is evaluated from the difference].  相似文献   

13.
The extraction behaviour of selenium(IV) and selenium(VI) with sodium diethyldithiocarbamate, ammonium pyrrolidinedithiocarbamate and dithizone in organic solvents has been investigated by means of flameless atomic-absorption spectrophotometry with a carbon-tube atomizer. The selective extraction of selenium(IV) and differential determination of selenium(IV) and selenium(VI) have been developed. With sodium diethyldithiocarbamate and carbon tetrachloride, when the aqueous phase/organic solvent volume ratio is 5 and the injection volume in the carbon tube is 20 microl, the sensitivity for selenium is 0.4 ng/ml for 1% absorption. The relative standard deviations are ca. 3%. Interference by many metal ions can he prevented by masking with EDTA. The proposed methods have been applied satisfactorily to determination of Se(IV) and Se(VI) in various types of water.  相似文献   

14.
A simple, accurate, sensitive and selective method was described for rapid determination of ultra-trace quantities of selenium. Selenium(IV) was collected on activated carbon (AC) after reduction to elemental Se by l-ascorbic acid. The collected selenium was then dissolved by oxidation reaction with bromate in acidic media and was indirectly determined through the bromide formation using square-wave voltammetry (OSWV). The total amount of Se(IV) and Se(VI) was collected on AC after its reduction by hydrazine. Selenium in the range 0.01-20 μg L−1 could be determined by this method. The method was used to the determination of Se(IV) and Se(VI) in natural water with satisfactory results.  相似文献   

15.
The very sensitive fluorimetric determination of selenium(IV) is based on its oxidation of the non-fluorescent 2-(α-pyridyl)thioquinaldinamide in slightly acidic solution (0.05–0.15 M sulphuric acid). The excitation and emission wavelengths are 350 nm and 500 nm, respectively. Linear calibration graphs are obtained for different ranges of selenium concentration between 0.01 ng ml?1 and 0.5 μg ml?1. Over sixty ions either do not interfere or can be masked in the determination of 1 ng ml?1 Se(IV). The method is applied successfully to various synthetic mixtures and to a native sulphur sample. The reaction is fast and the fluorescent system is stable for 24 hours.  相似文献   

16.
A sensitive and non chromatographic analytical procedure for the separation of inorganic selenium species in natural water has been performed. A combination of APDC coprecipitation and determination by an absolute thin layer Energy dispersive X-ray fluorescence spectrometry method was used. The influence of various analytical parameters such as element concentration, oxidation states and pH on the recoveries of Se (IV) was examined. The presence of organic matter and bicarbonate anions, typical components in Cuban groundwater samples, was also tested. Negligible matrix effects were observed. At pH 4 a 100% recovery was found for Se (IV). The coprecipitation recovery of the oxidized selenium species (Se (VI)) was null for the selected concentration range (5–100 μg L−1). When the Se (VI) was reduced by heating the solution with 4 mol L−1 HCl, quantitative recovery was also obtained. The determination of total selenium was conducted by the application of the oxidation–reduction process and the analytical procedure for Se (IV). Se (VI) content was calculated as the difference between total selenium and Se (IV). The detection limit was 0.13 μg L−1. The relative standard deviation was lower than 3.5% for 5 μg L−1 of Se (IV). The trueness of the method was verified by using standardized hydride generation-atomic absorption spectrometry technique. The results obtained using the EDXRF technique were in good agreement with the ones determined by HG-AAS. The proposed method was applied to the determination of Se (IV) in surface water and groundwater samples.  相似文献   

17.
A metal-organic framework nanocomposite was synthesized and applied to speciation analysis of Se(IV) and Se(VI). The sorbent is composed of MIL-101(Cr) and magnetite nanoparticles modified with dithiocarbamate. It is capably of selectively extracting Se(IV) at pH?=?1.85, while Se(VI) remains in solution. The total amount of selenium can then be determined by reducing Se(VI) to Se(IV) and also extracting it. The extraction parameters were optimized by employing design-of-experiments methodology. Selenium was then quantified by electrothermal AAS. Figures of merit include (a) a 10 ng·L?1 limit of detection, (b) a linear response in the 30 ng·L?1 to 10 μg·L?1 concentration range, and (a) a relative standard deviation of <11.5% for Se(IV). The method was validated by analyzing certified reference materials (water and tomato leaves). It was also applied to the speciation analysis of Se(IV) and Se(VI) in (spiked) water samples and of total selenium in agricultural samples.
Graphical abstract Schematic of the synthesis of a metal-organic framework nanocomposite for speciation analysis of Se(IV) and Se(VI). The sorbent is composed of MIL-101(Cr) and magnetite nanoparticles modified with dithiocarbamate. Selenium can be quantified by electrothermal AAS with a 10 ng L?1 detection limit.
  相似文献   

18.
A simple and sensitive catalytic spectrophotometric method was developed for the determination of trace amounts of selenium. The method is based on the catalytic effect of selenium in form Se(IV) on the reduction of Maxilon Blue-SG by sodium sulfide. Indicator reaction is followed spectrophotometrically by measuring the absorbance change at λmax=654 nm and constant temperature (30.0±0.1 °C) by fixed time method. Selenium could quantitatively be determined in the range 0.004-0.200 μg ml−1 Se(IV) with a detection limit of 0.205 ng ml−1 Se(IV). All of the variables that affected the reaction rate were investigated and established optimum conditions to give maximum sensitivity. The R.S.D.s of the method (N=12) for the Se(IV) concentrations of 0.004, 0.016, 0.040 and 0.160 μg ml−1 are between 2.27 and 0.32%, respectively, and depended on Se(IV) concentration. The interference effect of various anion and cations on the Se(IV) determination was also fully studied. The selectivity of catalytic reaction was greatly improved with the use of the strong cation exchange resin. The developed kinetic-catalytic reaction was applied to the determination of selenium in real samples as Antioxidant-S, Selsun (which is a healthcare product for the treatment of dandruff) and analytical grade sodium metabisulfite, and in spring water samples without any pre-concentration. The acceptable recoveries were obtained by the method for appropriate standard Se(IV) additions. The method is simple, practical and suitable for using in small laboratories owing to its precision, sensitivity and relative selectivity.  相似文献   

19.
Mattsson G  Nyholm L  Olin A  Ornemark U 《Talanta》1995,42(6):817-825
An analytical method was developed for the determination of total dissolved selenium in fresh waters, using linear sweep cathodic stripping voltammetry (CSV) in combination with UV photolytic digestion. Both the CSV method, based on the electrodeposition and stripping of Cu(2)Se, and the UV irradiation procedure were investigated in detail. In the presence of dissolved organic substances, as in freshwaters, Se(VI) is reduced to Se(IV) by UV irradiation in 0.1M hydrochloric acid. Glucose can be used as the carbon source in samples low in natural dissolved organic carbon (DOC). The photolytic yields of Se(IV) were about 90% in both cases. Five freshwater samples were analysed for total selenium by CSV after UV photolysis, and by hydride generation atomic absorption spectrometry (HG-AAS) after oxidative digestion followed by reduction with hydrochloric acid. The results agreed well and the concentrations were in the range 70-190 ng/l., well above the detection limit of the CSV method at 2 ng/l.  相似文献   

20.
This paper focuses on the analytical performance improvement of the coupled technique HPLC-ICPMS using on-line collision/reaction cell technology for selenium elemental and speciation analyses at the ng (Se) l(-1) level in aquatic environment. Collision/reaction cell operating parameters were optimised, resulting in selected conditions of 5.5 ml min(-1) H(2) and 0.5 ml min(-1) He mixture. The detection limits obtained were around 5 ng (Se) l(-1) for total analysis, and between 7 and 15 ng (Se) l(-1) depending on the species for speciation analysis. The capability of UV irradiation-hydride generation interfacing to increase detector sensitivity was also evaluated for speciation analysis. The detection limits obtained were in the range 2-8 ng (Se) l(-1) depending on the species. Moreover, such interface allowed to prevent bromine introduction to the ICPMS which is particularly convenient for selenium trace analysis in natural waters as (80)Se is preserved free from BrH interferences. The developed method was validated using certified water with low selenium content (TM Rain 95, NWRI, Canada) and applied to the analysis of different waters.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号