首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 30 毫秒
1.
The paper presents a procedure for the multi-element inorganic speciation of As(III, V), Se(IV, VI) and Sb(III, V) in natural water with GF-AAS using solid phase extraction technology. Total As(III, V), Se(IV, VI) and Sb(III, V) were determined according to the following procedure: titanium dioxide (TiO2) was used to adsorb inorganic species of As, Se and Sb in sample solution; after filtration, the solid phase was prepared to be slurry for determination. For As(III), Se(IV) and Sb(III), their inorganic species were coprecipitated with Pb-PDC, dissolved in dilute nitric acid, and then determined. The concentrations of As(V), Se(VI) and Sb(V) can be calculated by the difference of the concentrations obtained by the above determinations. For the determination of As(III), Se(IV) and Sb(III), palladium was chosen as a modifier and pyrolysis temperature was 800 °C. Optimum conditions for the coprecipitation were listed for 100 ml of sample solution: pH 3.0, 15 min of stirring time, 40.0 μg l−1 Pb(NO3)2 and 150.0 μg l−1 APDC. The proposed method was applied to the determination of trace amounts of As(III, V), Se(IV, VI) and Sb(III, V) in river water and seawater.  相似文献   

2.
Xiong C  He M  Hu B 《Talanta》2008,76(4):772-779
A new, simple, and selective method has been presented for the separation and preconcentration of inorganic arsenic (As(III)/As(V)) and selenium (Se(IV)/Se(VI)) species by a microcolumn on-line coupled with inductively coupled plasma-optical emission spectrometry (ICP-OES). Trace amounts of As(V) and Se(VI) species were separated and preconcentrated from total As and Se at desired pH values by a conical microcolumn packed with cetyltrimethylammonium bromide (CTAB)-modified alkyl silica sorbent in the absence of chelating reagent. The species adsorbed by CTAB-modified alkyl silica sorbent were quantitatively desorbed with 0.10 ml of 1.0 mol l−1 HNO3. Total inorganic arsenic and selenium were similarly extracted after oxidation of As(III) and Se(IV) to As(V) and Se(VI) with KMnO4 (50.0 μmol l−1). The assay of As(III) and Se(IV) were based on subtracting As(V) and Se(VI) from total As and total Se, respectively. All parameters affecting the separation/preconcentration of As(V) and Se(VI) including pH, sample flow rate and volume, eluent solution and volume have been studied. With a sample volume of 3.0 ml, the sample throughput was 24 h−1 and the enrichment factors for As(V) and Se(VI) were 26.7 and 27.6, respectively. The limits of detection (LODs) were 0.15 μg l−1 for As(V) and 0.10 μg l−1 for Se(VI). The relative standard deviations (RSDs) for nine replicate determinations at 5.0 μg l−1 level of As(V) and Se(VI) were 4.0% and 3.6%, respectively. The calibration graphs of the method for As(V) and Se(VI) were linear in the range of 0.5–1000.0 μg l−1 with a correlation coefficient of 0.9936 and 0.9992, respectively. The developed method was successfully applied to the speciation analysis of inorganic arsenic and selenium in natural water samples with satisfactory results.  相似文献   

3.
A simplified procedure based on ion-exchange separation of selenourea (Se-U) and selenocystamine (Se-CM), which have very close half-wave potential when they are simultaneously analyzed by voltammetric techniques, has been developed and optimized. Thus, selenocystamine remains in the cation exchanger Purolite C 100 H, whereas selenourea is found in the effluent and is determined by square wave cathodic stripping voltammetry using Na2CO3 as electrolyte. Selenocystamine is then eluted from the cation exchanger using 4 M HCl and analyzed by square wave cathodic stripping voltammetry in the HCl solution. For each voltammetric determination the corresponding parameters were investigated and optimized; the obtained detection limits were 0.3 ng Se mL–1 for Se-CM and 2 ng Se mL–1 for Se-U. A flow sheet for the separation of inorganic (Se(IV) and Se(VI)) and organoselenium compounds (Se-U, Se-CM, (CH3)2Se2, and (CH3)2Se) developed for their electrochemical detection is presented and it was successfully applied to a certified reference material, an environmental soil sample, and a urine sample.  相似文献   

4.
A speciation scheme allowing the study of selenium speciation in environmental samples has been developed in order to study the transfer mechanism in the system water/soil/plant/animal. This scheme is based on a set of sample treatment procedures followed by Se(IV) determination by Differential Pulse Cathodic Stripping Voltammetry (DPCSV). Se(IV) may be determined with a detection limit close to 25 ng l–1 and a linear response in the range 25–4000 ng l–1. However, humic substances, present in some natural waters and soils, which are adsorbed at the mercury drop electrode (HMDE) surface may alter the signal. This may be caused by a competition between adsorption of organic matter and mercury(II) selenide formation at the electrode surface. As a consequence the detection limit has been increased to ca. 250 ng l–1 in the presence of 1 mg l–1 fulvic acids; the linear response range is then shifted to 250–10000 ng l–1. After an extensive study of these interferences and using standard additions procedures, the Se(IV) content of various waters and soil extracts has been determined by DPCSV with a good reproducibility (RSD about 1%). Accuracy is satisfactory comparing the results obtained by DPCSV to those obtained by Hydride Generation/Quartz Furnace Absorption Atomic Spectrometry (HG/QFAAS).  相似文献   

5.
A flow injection–capillary electrophoresis system with contactless conductivity detection and hydrostatic-pressure-generated flow was used for the fast and sensitive speciation of Se(IV) and Se(VI). The sample throughput was 25 samples per hour using a background electrolyte solution containing 8.75 mM l-histidine (His) adjusted to pH 4.00 with acetic acid. The repeatability of peak areas (n=8) was better than 1.41% and the limits of detection were 190 g L–1 and 7.5 g L–1 for Se(IV) and Se(VI), respectively. The interference from carbonate, typically present in water samples, was eliminated by using a low-pH electrolyte in which carbonate is uncharged and migrates at the EOF front. The method was applied to the analysis of Se(IV) and Se(VI) in soil samples that were spiked with both selenium species and the results for recovery of both selenium species were in good agreement with their introduced concentrations.  相似文献   

6.
A novel, fast, and cheap nonchromatographic method for direct speciation of dissolved inorganic and organic selenium species in environmental and biological samples was developed by flow injection (FI) dual-column preconcentration/separation on-line coupled with ICP-MS determination. In the developed technique, the first column packed with nanometer-sized Al(2)O(3) could selectively adsorb the inorganic selenium [Se(IV), Se(VI)], and the retained inorganic selenium could be eluted by 0.2 mol l(-1) NaOH, while the organic Se [selenocystine (SeCys(2)) and selenomethionine (Se-Met)] was not retained. On the other hand, the second column packed with mesoporous TiO(2) chemically modified by dimercaptosuccinic acid (DMSA) could selectively adsorb Se(IV) and SeCys(2) and barely adsorb Se(VI) and Se-Met. When the sample solution was passed through the column 1, separation of inorganic selenium and organic selenium could be achieved first. Then, the effluent from column 1 was successively introduced into the column 2 and the speciation of organic selenium could be attained due to the different adsorption behaviors of Se-Met and SeCys(2) on DMSA modified TiO(2). After that, the eluent from column 1 contained Se(IV), and Se(VI) was adjusted to desired pH and injected into column 2, and the speciation of Se(IV) and Se(VI) could also be realized thanks to their different retention on column 2. The parameters affecting the separation were investigated systematically and the optimal separation conditions were established. The detection limits obtained for Se(IV), Se(VI), Se-Met and SeCys(2) were 45-210 ng l(-1) with precisions of 3.6-9.7%. The proposed method has been successfully applied for the speciation of dissolved inorganic and organic selenium in environmental and biological samples. In order to validate the methodology, the developed method was also applied to the speciation of selenium in certified reference material of SELM-1 yeast, and the determined values were in good agreement with the certified values.  相似文献   

7.
A very sensitive and simple method is presented for the determination of Se(IV) by Osteryang square-wave cathodic stripping voltammery (OSWCSV). The method is based on the reduction of Se(IV) with Bi(III) onto an edge-plane type of pyrolytic graphite substrate, followed by a cathodic potential scan. OSWCSV studies indicate that the reduced selenium produced a distinct catalytic hydrogen wave at -1150 mV vs. Ag/AgCl. The peak height of the catalytic hydrogen wave was directly proportional to the initial Se(IV) concentration in the ranges of 0.1 - 1.0 and 1.0 - 20.0 microg L(-1) (correlation coefficients 0.9800 and 0.9901, respectively) when the optimized parameters were used. A 3sigma detection limit of 0.025 microg L(-1)0 Se(IV) was obtained at 30 s deposition time. The relative standard deviation was 4.0% on replicate runs (n = 12) for the determinations of 0.10 microg L(-1) Se(IV). Analytical results of natural water samples demonstrate that the proposed method is applicable to speciation analysis of Se(IV) and Se(VI).  相似文献   

8.
A new on-line method for the separation of vanadium (IV) and vanadium (V) as well as for the removal of ClO+ mass spectral interference on vanadium determination by quadrupole-ICP-MS has been developed. The sample introduction system consists of a modified fused silica capillary coupled to a direct injection nebuliser (DIN), between the solvent delivery system and the ICP. Fused silica capillaries were treated with different anion and cation exchanger reagents and were tested for the retention of Cl and the separation of vanadium ions at μg l−1 levels. A suitable strong anion exchanger functional group (3-aminopropyltrimethoxy silane) was selected. Chlorine anions were retained in this anionic capillary and the separation between V(IV) and V(V) was possible in the pH range 2–4. The selections of instrumental ICP-MS conditions for the minimisation of the ClO+ interference were carefully considered. Factors affecting the chromatographic separation such as sample pH, sample flow rate, effect of methanol in the mobile phase and length of the capillary for the separation were optimised. The proposed methodology provides a simple and rapid method for vanadium speciation. A relative detection limit of 12 l−1 (i.e. absolute detection limits of 120 pg) for V(IV) based on peak height measurements was obtained. The relative standard deviation for V(IV) was 2.4% for a 10 μl injection (n=6).  相似文献   

9.
A nanocomposite prepared from graphene nanosheets and cerium nanoparticles (G/CeO2) was applied to the extraction of Se(IV), As(V), As(III), Cu(II) and Pb(II). The structure of G/CeO2 was investigated by scanning electron microscopy, X-ray diffraction and Raman spectroscopy. The optimal pH values for extraction are 4.0 for As(V), 3.0 for Se(IV), and 6.0 for both Cu(II) and Pb(II). The maximum adsorption capacity of G/CeO2 (expressed as mg·g?1) were calculated by the Langmuir model and are found to be 8.4 for As(V), 14.1 for Se(IV), 50.0 for Cu(II) and 75.6 for Pb(II). The sorbent was applied to dispersive solid phase microextraction prior to direct quantitation by energy-dispersive X-ray fluorescence spectrometry without the need for prior elution. The limits of detection (in ng·mL?1 units) are 0.10 for As(V), 0.11 for Se(IV), 0.19 for Cu(II) and 0.21 for Pb(II). The precisions (RSDs) are <4.5%. The accuracy of the method (1 - 4%) was verified by analysis of the certified reference material (CRM 1640a - natural water). The method was successfully applied in ultratrace element determination and to the speciation of selenium in environmental waters.
Graphical abstract The method gives possibility of simultaneous preconcentration and determination in environmental waters of both anionic (As(V) and Se(IV)) and cationic (Cu(II) and Pb(II)) forms of selected metals using graphene nanosheets and cerium nanoparticles. Se(IV) can be selective determined in the presence of Se(VI).
  相似文献   

10.
Qingyang Liu 《Mikrochimica acta》2009,167(1-2):141-145
An on-line nano-TiO2 controlled volatilization system was developed for inorganic selenium speciation based on the irradiation of thiourea with ultraviolet light. It provides an effective hyphenation unit for atomic fluorescence spectrometry. The effects of several factors such as the acidity, the concentration of thiourea, the amounts of TiO2, the concentration of KBH4 and the flow rates of carrier gas were investigated. Under optimal conditions, the limit detections for Se(IV) and Se(VI) were 2.38 and 3.39 ng mL?1 (100?µL injection, 3 times of the baseline noise), respectively. The relative standard for deviations of 50 ng mL?1 Se(IV) and Se(VI) were 3.7% and 2.7%, respectively. The method has been applied for determination of inorganic selenium species in real samples and the recoveries were between 93% and 98%.  相似文献   

11.
The use of solid-phase microextraction (SPME) with gas chromatography coupled to microwave-induced plasma atomic-emission detection (GC–MIP-AED) is described for selenite [Se(IV)] speciation. Aqueous standards were derivatised with sodium tetraethyl- or tetrapropylborate and extracted by SPME. Headspace extraction of the ethyl and propyl derivatives was studied. Relevant experimental conditions were optimised, including conditions for derivatisation and extraction and those of gas chromatographic analysis. The limits of detection achieved for headspace sampling of derivatised Se(IV) were in the low ng mL–1 range for both ethylation and propylation. When the method was applied to analysis of selenite in selenised yeast reference material results were in good agreement with the indicated values.  相似文献   

12.
The well-known method for the determination of selenium(IV), which is based on the cathodic stripping voltammetry of copper(I) selenide, has been adapted for application at the thin-film mercury electrode on glassy carbon (TFME). Insufficient reproducibility and sensitivity have been overcome by using a 0.1 mol/L HClO4 electrolyte solution containing 0.02 mol/L thiocyanate ions. Thiocyanate ions have been found to increase the peak height of the selenium response and shift it to more positive potentials. This behaviour is explained by an adsorption of SCN at the interface glassy carbon/Cu2Se and its action as an electron transfer catalyst between glassy carbon and copper(I) selenide. A 3σ-detection limit of 75 ng/L Se(IV) has been achieved. The relative standard deviation is 5.2% at 5 μg/L selenium(IV). The influence of cadmium(II), arsenic(III), zinc(II), iron(III) and lead(II) ions on the selenium response has been studied. In case of lead ions, a new signal occurred at more negative potentials than the reduction of Cu2Se. This signal, which is probably due to the reduction of PbSe, can also be used for the determination of selenium(IV). Received: 13 November 1996 / Revised: 19 December 1996 / Accepted: 24 December 1996  相似文献   

13.
An on-line flow injection system has been developed for the selective determination of Se(IV) and Se(VI) in citric fruit juices and geothermal waters by hydride generation atomic absorption spectrometry with microwave-aided heating prereduction of Se(VI) to Se(IV). The samples and the prereductant solutions (4 mol l−1 HCl for Se(IV) and 12 mol l−1 HCl for Se(VI)) which circulated in a closed-flow circuit were injected by means of a time-based injector. This mixture was displaced by a carrier solution of 1% v/v of hydrochloric acid through a PTFE coil located inside the focused microwave oven and mixed downstream with a borohydride solution to generate the hydride. The linear ranges were 0–120 and 0–100 μg l−1 of Se(IV) and Se(VI), respectively. The detection limits were 1.0 μg l−1 for Se(IV) and 1.5 μg l−1 for Se(VI). The precision (about 2.0–2.5% RSD) and recoveries (96–98% for Se(IV) and 94–98% for Se(VI)) were good. Total selenium values were also obtained by electrothermal atomic absorption spectrometry which agreed with the content of both selenium species. The sample throughput was about 50 measurements per hour. The main advantage of the method is that the selective determination of Se(IV) and Se(VI) in citric fruit juices and geothermal waters is performed in a closed system with a minimum sample manipulation, exposure to the environment, minimum sample waste and operator attention.  相似文献   

14.
A simple solid phase extraction procedure for speciation of selenium(IV) and selenium(VI) in environmental samples has been proposed prior to graphite furnace atomic absorption spectrometry. The method is based on the solid phase extraction of the selenium(IV)-ammonium pyrrolidine dithiocarbamate (APDC) chelate on the Diaion HP-2MG. After reduction of Se(VI) by heating the samples in the microwave oven with 4 mol l−1 HCl, the system was applied to the total selenium. Se(VI) was calculated as the difference between the total selenium content and Se(IV) content. The experimental parameters, pH, amounts of reagents, eluent type and sample volume were optimized. The recoveries of analytes were found greater than 95%. No appreciable matrix effects were observed. The adsorption capacity of sorbent was 5.20 mg g−1 Se (IV). The detection limit of Se (IV) (3sigma, n = 11) is 0.010 μg l−1. The preconcentration factor for the presented system was 100. The proposed method was applied to the speciation of selenium(IV), selenium(VI) and determination of total selenium in natural waters and microwave digested soil, garlic, onion, rice, wheat and hazelnut samples harvested various locations in Turkey with satisfactory results. In order to verify the accuracy of the method, certified reference materials (NIST SRM 2711 Montana Soil, NIST SRM 1568a Rice Flour and NIST SRM 8418 Wheat Gluten) were analyzed and the results obtained were in good agreement with the certified values. The relative errors and relative standard deviations were below 6 and 10%, respectively.  相似文献   

15.
An extremely sensitive stripping voltammetric procedure for low level measurements of platinum (II, IV) or ruthenium (III, IV) is reported. The method is based on the interfacial accumulation of the platinum (II) or ruthenium (III)-1-(2-pyridylazo)-2-naphthol complex on the surface of a hanging mercury drop electrode, followed by the reduction of the adsorbed complex during the cathodic scan. The peak potential was found to be –0.8 V vs. Ag/AgCl electrode and the reduction current of the adsorbed complex ions of platinum (II) or ruthenium (III) was measured by differential pulse cathodic stripping voltammetry. The optimum experimental conditions were: 1.5×10–7 mol/l of 1-(2-pyridylazo)-2-naphthol solution of pH 9.3, preconcentration potential of –0.2 V, accumulation time of 3 min and pulse amplitude of 50 mV with 4 mV s–1 scan rate in the presence of ethanol-water (30% v/v) — sodium sulphate (0.5 mol/l). Linear response up to 6.4 × 10–8 and 5.1 × 10–8 mol/l and a relative standard deviation (at 1.2×10–8 mol/l) of 2.4 and 1.6% (n=5) for platinum (II) and ruthenium (III) respectively were obtained. The detection limits of platinum and ruthenium were 3.2×10–10 and 4.1×10–10 mol/l, respectively. The electronic spectra of the Pt(II) — PAN and Ru(III) — PAN complexes were measured at pH 9.3 and the stoichiometric ratios of the complexes formed were obtained by the molar ratio method. The effects of some interfering ions on the proposed procedure were critically investigated. The method was found suitable for the sub-microdetermination of ruthenium (IV) and platinum (IV) after their reduction to ruthenium (III) and platinum (II) with sulphur dioxide in acid media. The applicability of the method for the analysis of binary mixtures of ruthenium (III) and (IV) or platinum (II) and (IV) has also been carried out successfully. The method is simple, rapid, precise, and promising for the determination of the tested metal ions at micro-molar concentration level.  相似文献   

16.
An on-line system is proposed consisting of an anion-exchange chromatographic column, microwave-induced thermooxidation of trimethylselenium in the presence of persulphate, and microwave-induced thermoreduction of Se(VI) to Se(IV) in HCl medium, followed by hydride generation and atomic absorption for the determination of trimethylselenium (TMeSe), Se(IV) and Se(VI). Trimethylselenium is eluted in the dead volume of an anion-exchange column (Hamilton PRP-X-100), before elution of Se(IV) and Se(VI). Optimum chromatographic conditions have been obtained using 100 mmol L–1 phosphate buffer (pH=6.8) H2PO 4 /HPO 4 2– as the mobile phase. Recoveries were around 100%, absolute detection limits were 1.1, 1.4 and 2.2 ng for TMeSe, Se(IV) and Se(VI), respectively. Precision was lower than 10% in all cases. The method has been applied to tap water.  相似文献   

17.
A flow-injection system for the determination of inorganic arsenic [As(III)/As(V)] and selenium species [Se(IV)/ Se(VI)] by electrochemical hydride generation, cryogenic trapping and atomic absorption spectrometry is described. A simple and robust electrochemical flow-through cell with fibrous carbon as cathodic material has been developed for the speciation of arsenic. A cold-trap system makes possible to eliminate interferences from methylated arsenic species. Without pre-reduction the system is selective to As(III) and Se(IV). The selectivity obtained with fibrous carbon as cathode material is compared to the selectivity obtained with a second electrochemical flow-through cell using a lead foil as cathode.  相似文献   

18.
Yatirajam V  Ram J 《Talanta》1974,21(12):1308-1311
A simple and rapid spectrophotometric determination of molybdenum is described. The molybdenum thiosulphate complex is extracted into isoamyl alcohol from 1·0–1·5M hydrochloric acid containing 36–40 mg of Na2S2O3·5H2O per ml. The absorbance at λmax = 475 nm obeys Beer's law over the range 0–32 μg of Mo per ml of solvent phase. Up to 5 mg/ml of Ti(IV), V(V), Cr(VI), Fe(III), Co(II), Ni(II), U(VI), W(VI), Sb(III), 1 mg/ml of Cu(II), Sn(II), Bi(V) and 10 μg/ml of Pt(IV) and Pd(II) do not interfere. Large amounts of complexing agents interfere. The method has been applied to analysis of synthetic and industrial samples.  相似文献   

19.
This paper presents a new method for the simultaneous speciation analysis of arsenic (As(III)-arsenite, As(V)-arsenate, DMA-dimethylarsinic acid, MMA-methylarsonic acid, and AsB-arsenobetaine) and selenium (Se(IV)-selenite, Se(VI)-selenate, Se-Methionine, and Se-Cystine), which was applied to a variety of seafood and onion samples. The determination of the forms of arsenic and selenium was undertaken using the High-Performance Liquid Chromatography Inductively Coupled Plasma Mass Spectrometry (HPLC–ICP–MS) analytical technique. The separation of both organic and inorganic forms of arsenic and selenium was performed using two analytical columns: an anion exchange column, Dionex IonPac AS22, containing an alkanol quaternary ammonium ion, and a double bed cation–anion exchange guard column, Dionex Ion Pac CG5A, containing, as a first layer, fully sulfonated latex for cation exchange and a fully aminated layer for anion exchange as the second layer. The ammonium nitrate, at pH = 9.0, was used as a mobile phase. The method presented here allowed us to separate the As and Se species within 10 min with a suitable resolution. The applicability was presented with different sample matrix types: seafood and onion.  相似文献   

20.
Ensafi AA  Khayamian T  Atabati M 《Talanta》2003,59(4):727-733
A sensitive cathodic stripping voltammetric method is developed for determination of lead(II), with adsorptive collection of complexes with Pyrogallol red (PGR) on to a hanging mercury drop electrode. After accumulation of the complex at −0.80 V vs. Ag/AgCl reference electrode, the potential is scanned in a negative direction from −0.20 to −0.50 V with differential pulse method. Then the reduction peak current for the lead(II)-PGR complex is measured at −0.39 V. The influence of reagent and instrumental variables was completely studied by factorial design analysis. The optimum analytical conditions for the determination of lead(II) were established. Under optimum conditions, lead(II) determined in the range of 0.1-30.0 ng ml−1 with a limit of detection of 0.06 ng ml−1. The method is successfully applied to determination of lead(II) in water sample.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号