首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 78 毫秒
1.
Multiwalled carbon nanotubes are attractive as sorbents for SPE because they can be used for enrichment of organic compounds and metal ions at trace levels. In this study, multiwalled carbon nanotubes were oxidized with concentrated HNO3, and then the oxidized multiwalled carbon nanotubes were modified with 5-(4'-dimethylamino-benzyliden)-rhodanine. The modified multiwalled carbon nanotubes were used as a solid sorbent for separation and preconcentration of trace amounts of Au(III) ions. The sorption of Au(III) ions was quantitative in the pH range of 2.0-5.0, whereas quantitative desorption occurred instantaneously with 5.0 mL 2.0 M Na2S2O3. The eluted solution was aspirated directly into the flame for atomic absorption spectrometry. The proposed method resulted in an enrichment factor of 94. The RSD of the method was +/- 1.11% (n=10, 2.0 microg/mL) and the LOD was 0.15 ng/mL. The calibration curve for Au(III) was linear between 0.53 ng/mL and 36.0 microg/mL in the initial solution, with an R2 value of 0.9999. The sorbent capacity of the modified multiwalled carbon nanotubes was 7.3 mg Au(III)/g sorbent. The influences of the experimental parameters, including sample pH, sample flow rate, eluent volume and flow rate, sample volume, and interference of some ions on the recoveries of the Au ions, were investigated. The proposed method was applied for preconcentration and determination of Au in different samples.  相似文献   

2.
A method for preconcentration of palladium at trace level on modified multiwalled carbon nanotubes columns and determination by flame atomic absorption spectrometry (FAAS) has been developed. Multiwalled carbon nanotubes (MWCNTs) were oxidized with concentrated HNO3 and the oxidized multiwalled carbon nanotubes were modified with 5-(4′-dimethylamino benzyliden)-rhodanine, and then were used as a solid sorbent for preconcentration of Pd(II) ions. Factors influencing sorption and desorption of Pd(II) ions were investigated. The sorption of Pd(II) ions was quantitative in the pH range of 1.0–4.5, whereas quantitative desorption occurs with 3.0 mL 0.4 mol L?1 thiourea. The amount of eluted palladium was measured using flame atomic absorption spectrometry. The effects of experimental parameters, including sample flow rate, eluent flow rate, and eluent concentration were investigated. The effect of coexisting ions showed no interference from most ions tested. The proposed method permitted a large enrichment factor (about 200). The relative standard deviation of the method was ±2.73% (for eight replicate determination of 2.0 μg mL?1 of Pd(II)) and the limit of detection was 0.3 ng mL?1. The method was applied to the determination of Pd(II) in water, road dust, and standard samples.  相似文献   

3.
A solid phase extraction method is presented for the preconcentration of trace lead ions on oxidized multiwalled carbon nanotubes (ox-MWCNTs). In the first step, the cationic Pb(II) complex of 2,2-bipyridyl is formed which, in a second step, is adsorbed on ox-MWCNTs mainly due to electrostatic and van der Waals interactions. The Pb(II) ions were then eluted with dilute nitric acid and quantified by FAAS. The effects of pH value, mass of sorbent, concentration of 2,2-bipyridyl, stirring time, of type, concentration and volume of eluent, of eluent flow rate and sample volume were examined. Most other ions do not affect the recovery of Pb(II). The limits of detection are 240 and 60 ng L?1 for sample volumes of 100 and 400 mL, respectively. The recovery and relative standard deviation are >95 % and 2.4 %, respectively. Other figures of merit include a preconcentration factor of 160 and a maximum adsorption capacity of 165 mg g?1. The method was successfully applied to the determination of Pb(II) in spiked tap water samples. The accuracy of the method was verified by correctly analyzing a certified reference material (NCS ZC85006; lead in tomatoes).
Figure
A solid phase extraction method is presented for the preconcentration of trace lead ions on oxidized multiwalled carbon nanotubes (ox-MWCNTs). Most other ions do not affect the recovery of Pb(II).  相似文献   

4.
Here, task‐specific ionic liquid solid‐phase extraction is proposed for the first time. In this approach, a thiourea‐functionalized ionic liquid is immobilized on the solid sorbent, multiwalled carbon nanotubes. These modified nanotubes packed into a solid‐phase extraction column are used for the selective extraction and preconcentration of ultra‐trace amounts of lead(II) from aqueous samples prior to electrothermal atomic absorption spectroscopy determination. The thiourea functional groups act as chelating agents for lead ions retaining them and so, give the selectivity to the sorbent. Elution of the retained ions can be performed using an acidic thiourea solution. The effects of experimental parameters including pH of the aqueous solution, type and amount of eluent, and the flow rates of sample and eluent solutions on the separation efficiency are investigated. The linear dependence of absorbance of lead on its concentration in the initial solution is in the range of 0.5–40.0 ng/mL with the detection limit of 0.13 ng/mL (3sb/m, n = 10). The proposed method is applicable to the analysis of red lipstick, pine leaves, and water samples for their lead contents.  相似文献   

5.
This paper describes the application of organo nanoclay, an easily prepared and stable solid sorbent, to the preconcentration of trace amounts of palladium ions in aqueous solution. The organo nanoclay was prepared by adding tetradecyldimethylbenzylamonium chloride onto montmorillonite, which was then modified with 1-(2-pyridylazo)-2-naphthol. The modified nanoclay was used as a solid sorbent for separation and preconcentration of trace amounts of Pd(II) ions, and a simple, sensitive, and economical method was developed for determination of trace amounts of palladium by flame atomic absorption spectrometry. The sorption of Pd(II) ions was quantitative in the pH range of 1.5-5.0, whereas quantitative desorption occurred with 5.0 mL of a mixture containing 1.0 M thiourea and 1.0 M HCl. The RSD of the method was +/- 2.1% (n = 10; concn = 0.5 microg/mL), and the LOD (3sigma(bl); sigma = SD and bl = blank) was 0.1 ng/mL. The calibration curve was linear for concentrations of 0.5-8.0 microg/mL in the initial solution, and the preconcentration factor was 140. The maximum capacity of the sorbent was 2.4 mg Pd(II)/g modified organo nanoclay. The influences of the experimental parameters, including sample pH, eluant volume, eluant type, sample volume, and interfering ions, on the recoveries of the palladium ion were investigated. The proposed method was applied to the preconcentration and determination of palladium in different samples.  相似文献   

6.
A simple, highly sensitive, accurate and selective method for determination of trace amounts of Pb(II) in water samples is presented. A novel Schiff base-chitosan-grafted multiwalled carbon nanotubes (S-CS-MWCNTs) solid-phase extraction adsorbent was synthesized by covalently grafting a Schiff base-chitosan (S-CS) onto the surfaces of oxidized MWCNTs. The stability of a chemically (S-CS-MWCNTs) especially in concentrated hydrochloric acid which was then used as a recycling and preconcentration reagent for further uses of (S-CS-MWCNTs). The method is based on selective chelation of Pb(II) on surfactant coated C18, modified with a Schiff base-chitosan-grafted multiwalled carbon nanotubes (S-CS-MWCNTs). The retained ions were then eluted with 4 mL of 4 M nitric acid and determined by flame atomic absorption spectrometry (FAAS) at 283.3 nm for Pb. The influence of flow rates of sample and eluent solutions, pH, break-through volume, effect of foreign ions on chelation and recovery were investigated. 1.5 g of surfactant coated C18 adsorbs 40 mg of the Schiff s base which in turn can retain 15.0 ± 0.9 mg of each of the two ions. The limit of detection (3σ) for Pb(II) was found to be 3.20 ng L?1. The enrichment factor for both ions are 100. The mentioned method was successfully applied on determination of lead in different water samples. The ions were also speciated by means of three columns system.  相似文献   

7.
In this work, the potential of modified multiwalled carbon nanotubes for separation and preconcentration of trace amounts of manganese ion is studied. Multiwalled carbon nanotubes were oxidized with concentrated HNO3 and then modified with loading 1-(2-pyridylazo)-2-naphtol. Mn(II) ions could be quantitatively retained by modified multiwalled carbon nanotubes in the pH range of 8–9.5. Elution of the adsorbed manganese was carried out with 5.0 mL of 0.1 mol L?1 HNO3. Detection limit is 0.058 ng mL?1 and analytical curve is linear in the range of 0.1 ng mL?1–5.0 μg mL?1 in the initial solution with a correlation coefficient 0.9977 and the preconcentration factor is 100. Relative standard deviation for eight replicate determination of 0.5 μg mL?1 of manganese in the final solution is 0.41%. The effects of the experimental parameters, including the sample pH, flow rates of sample and eluent solution, eluent type, breakthrough volume and interference ions, were studied for preconcentration of Mn(II) ions in detail to optimize the conditions. The method was successfully applied for separation, preconcentration and determination of manganese in different samples.  相似文献   

8.
Controlled-pore silica glass modified with N-propylsalicylaldimine (SCPSG) has been investigated as a surface-active matrix for the separation of some metal ions. The porous silica glass base was confirmed to have better stability towards hydrolysis in aqueous solution buffered at pH=9 in comparison to silica gel, which showed twice the surface area of controlled-pore silica glass. The different analytical parameters affecting the batch mode separation and preconcentration of trace Al(II), Ag(I) and Hg(II) in environmental samples using SCPSG, prior to their determination using inductively coupled plasma mass spectrometry (ICP-MS), were studied. The optimum conditions are pH 9.0 +/- 0.1, time of stirring 30 min and the eluent concentration 0.5 mol dm(-3) HNO3. The ion-exchange capacity of SCPSG with respect to Al(III), Ag(I) and Hg(II) was 0.27, 0.18 and 0.23 mmol g(-1), respectively. The recovery values for the metal ions were 96.8 +/- 0.86, 98.1 +/- 0.60 and 96.2 +/- 1.06%, and the analytical detection limits were 26.1, 1.49 and 0.44 pg cm(-3), respectively, for a preconcentration factor of 100. The method has been applied to the determination of the investigated metal ions in natural water samples as well as certified and reported samples and the results were found to be accurate.  相似文献   

9.
Multiwalled carbon nanotubes were impregnated with 4-(2-thiazolylazo)resorcinol and used for the separation and preconcentration of Cd(II), Pb(II), Zn(II) and Ni(II) ions from food samples. The analytes were quantitatively recovered at pH 7.0 and eluted with 3?mol?L?1 acetic acid. The effects of pH value, flow rate, eluent type and sample volume on the recoveries, and the effects of alkali, earth alkali and transition metals on the retention of the analytes were studied. The method was validated using the standard certified reference materials SRM 1570A (spinach leaves) and IAEA 336 (lichen), and the results were found to be compatible with the certified values of reference materials. The new enrichment procedure was applied to the determination of these ions in various food samples.
Figure
Multiwalled carbon nanotubes were impregnated with 4-(2-thiazolylazo)resorcinol and used for the separation and preconcentration of Cd(II), Pb(II), Zn(II) and Ni(II) ions from food samples. The analytes were quantitatively recovered at pH 7.0 and eluted with 3 mol L-1 acetic acid. The method was validated using the standard certified reference materials SRM 1570A (spinach leaves) and IAEA 336 (lichen), and the results were found to be compatible with the certified values of reference materials. The new enrichment procedure was applied to the determination of these ions in various food samples.  相似文献   

10.
A simple and rapid solid phase extraction?Cflow injection procedure is developed for on-line trace determination of Cu(II) and Pb(II) by flame atomic absorption spectrometry (FAAS). Multi-walled carbon nanotubes modified with a new Schiff??s base, 2,2??-(1E, 1E??)-(4-Methyl-1, 2-phenylene) bis (azen-1-yl-1-ylidine) bis (Methane-1-yl-1-ylidene) diphenol was used as a novel adsorbent material. Quantitative simultaneous extraction was obtained at pH 7.0. The retained metal ions were then eluted efficiently with 1.0?M HNO3 into the nebulizer of FAAS for on-line determination. Different variables affecting the preconcentration efficiency, including pH, eluent concentration, sample and eluent flow rates and sample loading time, were optimized. Using 3?min preconcentration of sample solution at flow rate of 5?mL?min?1 provided the enrichment factors of 20 and 21.5 for Cu(II) and Pb(II), respectively, at a sampling frequency of 17?h?1. The detection limits (3??) were found to be 0.80 and 1.80???g?L?1 for Cu(II) and Pb(II), respectively; and the relative standard deviations at 0.05???g?mL?1 of these metal ions were 1.7 and 1.8% (n?=?8), respectively. The accuracy was assessed by analysis of a certified reference material NKK-916 and the obtained results are in good agreement with certified amounts of Cu(II) and Pb(II). The proposed method was successfully applied to the determination of target analytes in different real samples.  相似文献   

11.
The present article reports the application of Thiosemicarbazide‐modified multiwalled carbon nanotubes (MWCNTs‐TSC) as a new, easily prepared selective and stable solid sorbent for the preconcentration of trace Co(II), Cd(II), Cu(II) and Zn(II) ions in aqueous solution prior to the determination by flame atomic absorption spectrometry. The studied metal ions can be adsorbed quantitatively on MMWNTs at pH 5.0 and then eluted completely with HNO3 (1.5 mol L?1) prior to their determination by flame atomic absorption spectrometry. The separation/preconcentration conditions of analytes were investigated, including the pH, the sample flow rate and volume, the elution condition and the interfering ions. The maximum adsorption capacity of the adsorbent at optimum conditions were found to be 32.5, 27.3, 44.5 and 34.1 mg g?1 for Co(II), Cd(II), Cu(II) and Zn(II), and the detection limits of the method were found to be 0.28, 0.13, 0.21 and 0.17 μg L?1, respectively. The proposed method was successfully applied for extraction and determination of the analytes in well water, sea water, wastewater, soil, and blood samples.  相似文献   

12.
A new preconcentration method was developed for the determination of trace amounts of Cu(II), Fe(III), Pb(II), Ni(II), and Cd(II) on a double-walled carbon nanotube disk. 4-(2-Thiazolylazo) resorcinol was used as a complexing reagent. The effects of parameters, including pH of the solutions, amounts of complexing reagent, eluent type, sample volume, flow rates of solutions, and matrix ions were examined for quantitative recoveries of the studied analyte ions. The retained metal ions were eluted by 2 M HNO3. The LOD values for the analytes were in the range of 0.7-4.4 microg/mL. Natural water samples and standard reference materials were analyzed by the presented method.  相似文献   

13.
A solid phase extraction method for simultaneous preconcentration and separation of trace amounts of copper, cobalt and silver in different samples, using a column packed with modified Amberlyst®15 resin is developed. Amberlyst®15 resin was modified with 5-(4-dimethylaminobenzylidene)rhodanine and then the modified resin was used as a support material for the solid phase extraction and preconcentration of Cu(II), Co(II) and Ag(I) ions from aqueous solution in the pH range 3.5–4.5. The adsorbed metal ions on the column were quantitatively eluted with a 7% thiourea solution prepared in 2?mol?L?1 HNO3, which were detected by flame atomic absorption spectrometry. The effects of analytical parameters including pH of the solution, eluent type, flow rate of samples, eluent and matrix ions were investigated for optimization of the presented procedure. The detection limits were 2.1, 0.9 and 0.9?ng?mL?1 for Cu(II), Co(II) and Ag(I) ions, respectively based on the three times the standard deviations of the blanks. The preconcentration factor was 112.5. The calibration graphs were obtained in the ranges of 0.05 to 10.0, 0.03 to 13.0 and 0.04 to 9.0?µg?mL?1 for Cu(II), Co(II) and Ag(I) ions concentrations, respectively. Relative standard deviations (n?=?7) for Cu(II), Co(II) and Ag(I) ions were found ±2.5 %, ±0.84% and ±3.8% respectively. The method was applied to the determination of mentioned ions in well water, waste water and lettuce sample.  相似文献   

14.
In the present study, the ?5-(4-dimethylaminobenzylidene)rhodanin-modified SBA-15? was applied as stable solid sorbent for the separation and preconcentration of trace amounts of cobalt ions in aqueous solution. SBA-15 was modified by ?5-(4-dimethylaminobenzylidene)rhodanin reagent. The sorption of Co2+ ions was done onto modified sorbent in the pH range of 6.8–7.9 and desorption occurred in 5.0 mL of 3.0 mol L?1 HNO3. The results exhibit a linear dynamic range from 0.01 to 6.0 mg L?1 for cobalt. Intra-day (repeatability) and inter-day (reproducibility) for 10 replicated determination of 0.06 mg L?1 of cobalt was ±1.82% and ?±1.97%?. Detection limit was 4.2 µg L?1 (3Sb, n = 5) and preconcentration factor was 80. The effects of the experimental parameters, including the sample pH, flow rates of sample and eluent solution, eluent type and interference ions were studied for the preconcentration of Co2+. The proposed method was applied for the determination of cobalt in standard samples, water samples and agricultural products.  相似文献   

15.
建立了多壁碳纳米管分离富集-原子荧光光谱法测定化妆品中痕量汞(Hg2+)的新方法,考察了Hg2+在碳纳米管填充固相萃取柱上的吸附行为,优化出了最佳吸附和洗脱条件。优化后的实验条件:pH4,流速2.0 mL/min,络合剂1gL吡咯烷二硫代氨基甲酸铵(APDC)溶液用量1.0 mL;洗脱剂采用6 mol/LHNO3,流速...  相似文献   

16.
The adsorption behavior of multiwalled carbon nanotubes (MWNTs) toward copper has been investigated systemically, and a new method has been developed for the determination of trace copper in water samples based on preconcentration with a microcolumn packed with MWNTs prior to its determination by flame atomic absorption spectrometry. The optimum experimental parameters for preconcentration of copper, such as pH of the sample, sample flow rate and volume, elution solution and interfering ions, have been investigated. Copper can be quantitatively retained by MWNTs in the pH range 5-8, and then eluted completely with 0.5 M HNO3. The detection limit of this method for Cu was 0.42 ng/mL, and the RSD was 3.5% at the 10 ng/mL Cu level. The method was validated using a certified reference material, and has been successfully applied for the determination of trace copper in water samples.  相似文献   

17.
A solid phase extraction method is presented for the selective preconcentration and/or separation of trace Pb(II) on multiwalled carbon nanotubes modified with 2-aminobenzothiazole. Inductively coupled plasma optical emission spectrometry was used for detection. The effects of pH, shaking time, sample flow rate and volume, elution condition and interfering ions were examined using batch and column procedures. An enrichment factor of 100 was accomplished. Common other ions do not interfere in both the separation and determination. The maximum adsorption capacity of the sorbent at optimum conditions is 60.3?mg?g?1 of Pb(II), the detection limit (3??) is 0.27?ng?mL?1, and the relative standard deviation is 1.6% (n?=?8). The method was validated using a certified reference material, and has been applied to the determination of trace Pb(II) in water samples with satisfactory results.
Figure
2-Aminobenzothiazole modified multiwalled carbon nanotubes has been developed to separate and concentrate trace Pb(II) from aqueous samples. Parameters that affect the sorption and elution efficiency were studied in batch and column modes, and the new sorbent (MWCNTs-ABTZ) presents high selectivity and adsorption capacity for the solid phase extraction of trace Pb(II).  相似文献   

18.
A solid co-precipitated material obtained from an ion-pair of 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol (5-Br-PADAP) and tetraphenylborate (TPB), and microcrystals of naphthalene has been tried as an adsorbent for the column preconcentration of copper(I), iron(II), nickel(II) and Zn(II). The retention of the metal ions was found to be maximum and constant in the pH range 3.0-8.0 for Cu, 3.8-7.5 for Fe, 4.5-7.5 for Ni and 8.5-11.0 for Zn. The elements were determined by FAAS after dissolving the metal along with the adsorbent in an organic solvent (10 mL of DMF). The characteristic concentration for 1% absorption was found to be 0.0332, 0.0536, 0.0537 and 0.0142 (aqueous medium 0.0512, 0.0638, 0.1294 and 0.0216) microg mL(-1) for Cu, Fe, Ni and Zn, respectively. The calibration plot was linear in the range 1.5-20.0, 2.0-38.0, 2.5-25.0 and 0.5-15.0 micro g in the final 10 mL of DMF solution for Cu, Fe, Ni and Zn, respectively. Various parameters such as pH, volume of buffer, amount of adsorbent, flow rate, preconcentration factor and effect of diverse salts and cations were studied. The optimised conditions were utilized for the determination of Cu, Fe, Ni and Zn in various water, beverage and human hair samples.  相似文献   

19.
Multiwalled carbon nanotubes were grafted with tris(2-aminoethyl)amine (MWCNTs-TAA) and employed for solid phase extraction and preconcentration of trace lead ions prior to its determination by inductively coupled plasma optical emission spectrometry. The material was characterized by FT-IR and Raman spectroscopy, thermosgravimetric and elemental analysis. The effects of pH value, shaking time, sample volume, elution conditions and potentially interfering ions were investigated. Under the optimum conditions, the maximum adsorption capacity is 38?mg?g?1 of Pb(II), the detection limit is 0.32?ng?mL?1, the enrichment factor is 60, and the relative standard deviation is 3.5% (n?=?6). The method has been applied to the preconcentration of trace amounts of Pb(II) in environmental water samples with satisfactory results.
Figure
Oxidized multiwalled carbon nanotubes grafted with tris(2-aminoethyl)amine (MWCNTs-TAA) is prepared and employed as solid phase extraction sorbent to determinate the trace Pb(II) in water samples. The method has been applied to the preconcentration of trace amount of Pb(II) in water samples with satisfactory results.  相似文献   

20.
A solid phase extraction procedure has been developed using multiwalled carbon nanotubes (MWCNTs) as a solid sorbent and quinalizarin [1,2,5,8-tetrahydroxyanthracene-9,10-dione] as a chelating agent for separation and preconcentration of trace amounts of some heavy metal ions, Cd(II), Cu(II), Ni(II), Pb(II) and Zn(II) before their determination by flame atomic absorption spectroscopy (FAAS). The influences of the analytical parameters, including pH, amounts of quinalizarin and adsorbent, sample volume, elution conditions such as volume and concentration of eluent, flow rates of solution and matrix ions, were investigated for the optimum recoveries of the analyte ions. No interference effects were observed from the foreign metal ions. The preconcentration factor was 100. The detection limit (LOD) for the investigated metals at the optimal conditions were observed in the range of 0.30–0.65 μg L?1. The relative standard deviation (RSDs), and the recoveries of standard addition for this method were lower than 5.0% and 96–102%, respectively. The new procedure was successfully applied to the determination of analytes in food, water and environmental samples with satisfactory results.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号