首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 390 毫秒
1.
A cycloalkyl aliphatic saccharide, 5-cyclohexyl-1-pentyl-beta-D-maltoside (CYMAL-5), was evaluated as a novel additive in a high-throughput in-gel protein digestion system using 96-well plates. Addition of 0.1% CYMAL-5 (final concentration) during trypsin treatment was compatible with both matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) and liquid chromatography/tandem mass spectrometry (LC/MS/MS) analysis, and gave a better digestion efficiency than n-octylglucoside, which we previously reported. In-gel reduction and alkylation of Cys residues under denaturing conditions also improved the sequence coverage of peptides. In-gel tryptic digestion with the optimum combination of 0.5 mm thick gels, negative staining, alkylation under denaturing conditions (6 M guanidine hydrochloride), and digestion in the presence of CYMAL-5, gave excellent performance especially for membrane protein analysis, where recovery of hydrophobic peptides was markedly enhanced. The new protocol is simple and convenient, and should be widely applicable to gel-based proteomics.  相似文献   

2.
The availability of easy-to-handle, sensitive, and cost-effective protein staining protocols for 2-DE, in conjunction with a high compatibility for subsequent MS analysis, is still a prerequisite for successful proteome research. In this article we describe a quick and easy-to-use methodological protocol based on sensitive, homogeneous, and MS-compatible silver nitrate protein staining, in combination with an in-gel digestion, employing the Millipore 96-well ZipPlate system for peptide preparation. The improved quality and MS compatibility of the generated protein digests, as compared to the otherwise weakly MS-compatible silver nitrate staining, were evaluated on real tissue samples by analyzing 192 Coomassie-stained protein spots against their counterparts from a silver-stained 2-DE gel. Furthermore, the applicability of the experimental setup was evaluated and demonstrated by the analysis of a large-scale MALDI-TOF MS experiment, in which we analyzed an additional ~1000 protein spots from 2-DE gels from mouse liver and mouse brain tissue.  相似文献   

3.
Chmelík J  Mazanec K  Slais K 《Electrophoresis》2007,28(18):3315-3323
A new proteomic staining-free method for simultaneous identification of proteins and determination of their pI values by using low-molecular-mass pI markers is described. It is based on separation of proteins in gels by IEF in combination with mass spectrometric analysis of both peptides derived by in-gel digestion and low-molecular-mass pI markers extracted form the same piece excised from the gel. In this method, the pI markers are mixed with a protein mixture (a commercial malted barley protein extract) deposited on a gel and separated in a pH gradient. Color pI markers enable supervision of progress of focusing process. Several separated bands of the pI markers (including separated proteins) were excised and the pI markers were eluted from each gel piece by water/ethanol and identified by MALDI-TOF/TOF MS. The remaining carrier ampholytes were then washed out from gel pieces and proteins were in-gel digested with trypsin or chymotrypsin. Obtained peptides were measured by MALDI-TOF/TOF MS and proteins were identified via protein database search. This procedure allows omitting time-consuming protein staining and destaining procedures, which shortens the analysis time. For comparison, other IEF gels were stained with CBB R 250 and proteins in the gel bands were identified. Similarity of the results confirmed that our approach can give information about the correct pI values of particular proteins in complex samples at significantly shorter analysis times. This method can be very useful for identification of proteins and their post-translational modifications in prefractioned samples, where post-translational modifications (e.g., glycation) are frequent.  相似文献   

4.
Proteomics requires an optimized level of sample-processing, including a minimal sample-processing time and an optimal peptide recovery from protein digests, in order to maximize the percentage sequence coverage and to improve the accuracy of protein identification. The conventional methods of protein characterization from one-dimensional or two-dimensional gels include the destaining of an excised gel piece, followed by an overnight in-gel enzyme digestion. The aims of this study were to determine whether: (1) stained gels can be used without any destaining for trypsin digestion and mass spectrometry (MS); (2) tryptic peptides can be recovered from a matrix-assisted laser desorption/ionization (MALDI) target plate for a subsequent analysis with liquid chromatography (LC) coupled to an electrospray ionization (ESI) quadrupole ion trap MS; and (3) an overnight in-gel digestion is necessary for protein characterization with MS. These three strategies would significantly improve sample throughput. Cerebrospinal fluid (CSF) was the model biological fluid used to develop these methods. CSF was desalted by gel filtration, and CSF proteins were separated by two-dimensional gel electrophoresis (2DGE). Proteins were visualized with either silver, Coomassie, or Stains-All (counterstained with silver). None of the gels was destained. Protein spots were in-gel trypsin digested, the tryptic peptides were purified with ZipTip, and the peptides were analyzed with MALDI and ESI MS. Some of the samples that were spotted onto a wax-coated MALDI target plate were recovered and analyzed with ESI MS. All three types of stained gels were compatible with MALDI and ESI MS without any destaining. In-gel trypsin digestion can be performed in only 10-60 min for protein characterization with MS, the sample can be recovered from the MALDI target plate for use in ESI MS, and there was a 90% reduction in sample-processing time from overnight to ca. 3 h.  相似文献   

5.
Polyacrylamide gel electrophoresis is widely used for protein separation and it is frequently the final step in protein purification in biochemistry and proteomics. Using a commercially available amine-reactive isobaric tagging reagent (iTRAQ) and mass spectrometry we obtained reproducible, quantitative data from peptides derived by tryptic in-gel digestion of proteins and phosphoproteins. The protocol combines optimized reaction conditions, miniaturized peptide handling techniques and tandem mass spectrometry to quantify low- to sub-picomole amounts of (phospho)proteins that were isolated by sodium dodecyl sulfate polyacrylamide gel electrophoresis (SDS-PAGE). Immobilized metal affinity chromatography (FeIII-IMAC) was efficient for removal of excess reagents and for enrichment of derivatized phosphopeptides prior to matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) analysis. Phosphopeptide abundance was determined by liquid chromatography/tandem mass (LC/MS/MS) using either MALDI time-of-flight/time-of-flight (TOF/TOF) MS/MS or electrospray ionization quadrupole time-of-flight (ESI-QTOF) MS/MS instruments. Chemically labeled isobaric phosphopeptides, differing only by the position of the phosphate group, were distinguished and characterized by LC/MS/MS based on their LC elution profile and distinct MS/MS spectra. We expect this quantitative mass spectrometry method to be suitable for systematic, comparative analysis of molecular variants of proteins isolated by gel electrophoresis.  相似文献   

6.
High-sensitivity, high-throughput analysis of proteins for proteomics studies is usually performed by polyacrylamide gel electrophoresis in combination with mass spectrometry. However, the quality of the data obtained depends on the in-gel digestion procedure employed. This work describes an improvement in the in-gel digestion efficiency for matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) analysis. A dramatic improvement in the coverage of tryptic peptides was observed when n-octyl glucoside was added to the buffer. Whole cell extracted proteins from S. cerevisiae were separated by two-dimensional gel electrophoresis and stained with silver. Protein spots were identified using our improved in-gel digestion method and MALDI-TOFMS. In addition, the mass spectra obtained by using the matrix alpha-cyano-4-hydroxycinnamic acid (CHCA) were compared with those obtained using 2,5-dihydroxybenzoic acid (DHB). The DHB matrix usually gave more peaks, which led to higher sequence coverage and, consequently, to higher confidence in protein identification. This improved in-gel digestion protocol is simple and useful for protein identification by MALDI-TOFMS.  相似文献   

7.
Zhou J  Li J  Li J  Chen P  Wang X  Liang S 《Electrophoresis》2010,31(23-24):3816-3822
Sample preparation holds an important place in MS-based proteome analysis. For effective proteolysis and MS analysis, it is essential to eliminate the interferences while extracting the analytes of interest from complex mixtures. To address this, herein we describe a new dried polyacrylamide gel absorption method. In this method, the protein sample prepared using high concentration of SDS was directly and completely absorbed by vacuum-dried polyacrylamide gel, and then the interfering substances including SDS and some other salts were efficiently removed by in-gel washing steps while retaining the denatured proteins in the gel, thus offering a clean environment amenable to downstream buffer exchange, proteolytic digestion and digest recovery, etc. In combination with in-gel digestion and LC-MS/MS, the newly developed method was applied to the proteome analyses of membrane-enriched fraction and whole tissue homogenate. It was demonstrated that the method is suitable for the analysis of a complex biological sample and can be widely used for sample cleanup in shotgun proteome analyses.  相似文献   

8.
2-DE combined with LC-MS/MS has become a routine, reliable protein separation and identification technology for proteome analysis. The demand for large-scale protein identifications after 2-DE separation requires a sensitive and high-throughput LC-MS/MS method. In this report, a simple, splitless, fully automated capillary LC-MS/MS system was described for the large-scale identification of proteins from gels stained with either silver or CBB. The gel samples were digested and peptides were extracted using an in-gel digestion workstation. The peptides were automatically introduced into a capillary column by an autosampler connected to an HPLC pump. A nanoLC pump was then used to deliver the gradient and elute the peptides from the capillary column directly into an LCQ IT mass spectrometer. Neither a peptide trapping setting nor a flow split is needed in this simple setup. The collected MS/MS spectra were then automatically searched by SEQUEST, and filtered and organized by DTASelect. Hundreds of silver-stained or CBB-stained Shewanella oneidensis, Geobacter sulfurreducens, and Geobacter metallireducens proteins separated by denaturing or nondenaturing 2-DE were digested and routinely analyzed using this fully automated muLC-MS/MS system. High peptide hits and sequence coverage were achieved for most CBB-stained gel spots. About 75% of the spots were found to contain multiple proteins. Although silver staining is not commonly thought to be optimal for MS analysis, protein identifications were successfully obtained from silver-stained 2-DE spots detected using methods with and without formaldehyde for protein fixation.  相似文献   

9.
The design of an extended-run 96-well sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE) system and the development of protein detection technology based upon fluorescein derivatives that bind to peptide epitope tags, allows the creation of a truly high-throughput analysis of protein expression, where less than 20 min are needed to separate proteins and analyze results. We demonstrate the overall capabilities of such a method combination in a complex cell lysate background, while comparing the specific results obtained using a biarsenical fluorescein-derivative and tetracysteine epitope-tagged proteins with total protein staining using a fluorescent gel stain and with Western blotting where an anti-oligohistidine (His) tag antibody has been employed. When applied on purified target proteins without extraneous protein background, the demonstrated sensitivity of the assay on the extended-run 96-array precast SDS-PAGE system allows detection of quantities of tagged protein as low as 1 pmol per band.  相似文献   

10.
The coupling of the widely used separation technique of conventional sodium dodecylsulfate polyacrylamide gel electrophoresis (SDS-PAGE) with the mass accuracy measurement capability of mass Spectrometry (MS) provides a very powerful analytical technique. However, at present, there is no simple, definitive method for coupling the two methods. Typically, separated proteins are extracted from the gel, either as the native protein or as a peptide mixture after in-gel proteolytic digestion, and then analyzed by mass Spectrometry. However, the various extraction techniques described previously have been labor intensive and require a large number of steps. The mass Spectrometry analysis of very low concentrations of in vivo derived proteins requires minimum sample handling and on-line concentration. Therefore, we have developed an efficient microelectroelution technique that is applied in a single step manner and contains an on-line concentration device. Initial results from this system have shown a high efficiency of analyte elution from the gel and a simple, robust technique for the coupling of SDS-containing gels with MALDI-TOF-MS analysis and a capability of analyzing proteins at the subpicomole level.  相似文献   

11.
Mass spectrometry (MS) together with genome database searches serves as a powerful tool for the identification of proteins. In proteome analysis, mixtures of cellular proteins are usually separated by sodium dodecyl sulfate (SDS) polyacrylamide gel-based two-dimensional gel electrophoresis (2-DE) or one-dimensional gel electrophoresis (1-DE), and in-gel digested by a specific protease. In-gel protein digestion is one of the critical steps for sensitive protein identification by these procedures. Efficient protein digestion is required for obtaining peptide peaks necessary for protein identification by MS. This paper reports a remarkable improvement of protein digestion in SDS polyacrylamide gels using an acid-labile surfactant, sodium 3-[(2-methyl-2-undecyl-1,3-dioxolan-4-yl)methoxy]-1-propanesulfonate (ALS). Pretreatment of gel pieces containing protein spots separated by 2-DE with a small amount of ALS prior to trypsin digestion led to increases in the digested peptides eluted from the gels. Consistently, treatment of gel pieces containing silver-stained standard proteins and those separated from tissue extracts resulted in the detection of increased numbers of peptide peaks in spectra obtained by matrix-assisted laser desorption/ionization time of flight mass spectrometry (MALDI-TOFMS). Hence the present protocol with ALS provides a useful strategy for sensitive protein identification by MS.  相似文献   

12.
Complex III of the mitochondrial electron transport chain, ubiquinol-cytochrome c reductase, was isolated by blue native polyacrylamide gel electrophoresis. Ten of the 11 polypeptides present in this complex were detected directly by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) following electroelution of the active complex. Tryptic and chymotryptic digestion of the complex permit the identification of specific peptides from all of the protein subunits with 70% coverage of the 250 kDa complex. The mass of all 11 proteins was confirmed by second dimension Tricine sodium dodecyl sulfate polyacrylamide gel electrophoresis (SDS-PAGE) and elution of the separated polypeptides. Additionally, the identity of the core I, core II, cytochrome c and the Rieske iron-sulfur protein were confirmed by liquid chromatography/tandem mass spectrometry (LC/MS/MS) characterization of the peptides generated by in-gel trypsin digestion of the SDS-PAGE separated proteins. The methodology demonstrated for analyzing this membrane-bound electron transport complex should be applicable to other membrane complexes, particularly the other mitochondrial electron transport complexes. The MS analysis of the peptides obtained by in-gel digestion of the intact complex permits the simultaneous characterization of the native proteins and modifications that contribute to mitochondrial deficits that have been implicated as contributing to pathological conditions.  相似文献   

13.
黄珍玉  杨芃原 《分析化学》2005,33(9):1207-1210
报道了改进的凝胶电泳分离后蛋白质溶液酶解方法。将凝胶分离后的蛋白转移到PVDF膜上,直接用碳酸氢铵中和从膜上的蛋白洗脱溶液至弱碱性,并在此溶液中直接进行蛋白酶解。方法避免了胶内杂质对质谱鉴定蛋白质的干扰。用标准蛋白进行了验证,并在此基础上鉴定了中国仓鼠卵巢细胞(CHO)细胞系中的16个蛋白点。与已报道的方法比较,本方法蛋白回收率提高到90%左右;与传统的胶内酶解方法比较,本方法具操作简单,实验流程较短;涉及的试剂较胶内酶解少,因此带来的杂质影响小;在蛋白转印以后还可与许多其它实验方法相结合,比如免疫印迹等优点。  相似文献   

14.
Manabe T  Jin Y 《Electrophoresis》2007,28(12):2065-2079
Previously, we have reported on the analysis of human plasma proteins on a nondenaturing micro-2-DE (mu2-DE) gel, using in-gel digestion followed by MALDI-MS and PMF [1]. Many of the spots on the mu2-DE gel showed apparent masses much larger than the calculated masses of their assigned polypeptides, suggesting noncovalent or covalent interactions between the polypeptides. In the present study, we aimed to further analyze the plasma protein spots on a nondenaturing mu2-DE gel, on which protein/polypeptide interactions have been suggested. The proteins in the spots were extracted under alkaline conditions and subjected to 3-D separation using SDS-PAGE in microslab gel format (muSDS gel) with or without the sample treatment of reduction-alkylation. The clear bands in each lane of the muSDS gels demonstrated the successful extraction of proteins from the relevant gel spot and visualized the relative contents of the polypeptides in the spot. Most of the bands were assigned by in-gel digestion followed by MALDI-MS and PMF (MASCOT/Swiss-Prot). The large discrepancy between the apparent mass value of a protein spot and the estimated mass values of the polypeptide bands on a nonreducing muSDS gel strongly suggested noncovalent polypeptide interactions. The differences in the polypeptide separation patterns on the muSDS gels, between with and without the treatment of reduction-alkylation, confirmed polypeptide disulfide bonding. The method employed here, aiming to integrate information on the proteins separated on nondenaturing 2-DE gels with that on the interactions between polypeptides, would help the comprehensive understanding of complex protein systems.  相似文献   

15.
Over the past several years, a large effort has been focused on improvements of two-dimensional (2-D) gel electrophoresis-based proteomics technology, and on development of novel approaches for proteome analysis. Here, we describe the application of an alternative strategy for the analysis of complex proteomes. The strategy combines isoelectric focusing in immobilized pH gradient strips (in-gel IEF), mass spectrometry (MS), and bioinformatics. A protein mixture is separated by in-gel IEF, and the entire strip is cut into a set of gel sections. Proteins in each gel section are digested with trypsin, and the tryptic peptides are subjected to liquid chromatography-nanoelectrospray-quadrupole ion-trap tandem mass spectrometry (LC-ESI-MS/MS). The LC-ESI-MS/MS data are used to identify the proteins through searches of a protein sequence database. Using this in-gel IEF-LC-MS/MS strategy, we have identified 127 proteins from a human pituitary. This study demonstrates the potential of the in-gel IEF-LC-MS/MS approach for analyses of complex mammalian proteomes.  相似文献   

16.
In this work, a high-throughput and high-performance bioanalytical system is described that is capable of extracting and analyzing 1152 plasma samples within 10 hours. A Zymark track robot system interfaced with a Tecan Genesis liquid handler was used for simultaneous solid-phase extraction of four 96-well plates in a fully automated fashion. The extracted plasma samples were injected onto four parallel monolithic columns for separation via a four-injector autosampler. The use of monolithic columns allowed for fast and well-resolved separations at a considerably higher flow rate without generating significant column backpressure. This resulted in a total chromatographic run cycle time of 2 min on each 4.6 x 100 mm column using gradient elution. The effluent from the four columns was directed to a triple quadrupole mass spectrometer equipped with an indexed four-probe electrospray ionization source (Micromass MUX interface). Hence, sample extraction, separation, and detection were all performed in a four-channel parallel format that resulted in an overall throughput of about 30 s per sample from plasma. The performance of this system was evaluated by extracting and by analyzing twelve 96-well plates (1152) of human plasma samples spiked with oxazepam at different concentrations. The relative standard deviation (RSD) of analyte sensitivity (slope of calibration curve) across the four channels and across the 12 plates was 5.2 and 6.8%, respectively. An average extraction recovery of 77.6% with a RSD of 7.7% and an average matrix effect of 0.95 with a RSD of 5.2% were achieved using these generic extraction and separation conditions. The good separation efficiency provided by this system allowed for rapid method development of an assay quantifying the drug candidate and its close structural analog metabolite. The method was cross-validated with a conventional liquid chromatography/tandem mass spectrometry (LC/MS/MS) assay.  相似文献   

17.
Recently, we have developed liquid chromatography/tandem mass spectrometry (LC/MS/MS)-based methods for the quantitation of pegylated therapeutic proteins in plasma. The methods are based on the LC/MS/MS detection of a surrogate peptide generated from trypsin digestion of the therapeutic protein. Various parameters related to the bioanalytical methods were evaluated and optimized, including the preparation of calibration standards and quality control samples, sample extraction, internal standard selection and its stage of addition, trypsin digestion, and non-specific binding. In this paper, we report the development of a method for a specific pegylated therapeutic protein and detail the various optimization steps undertaken. Simple extraction of the pegylated therapeutic protein from plasma was achieved via the precipitation of the endogenous proteins in plasma using acidic isopropanol and the resulting supernatant extract was subjected to trypsin digestion. A unique tryptic peptide arising from the pegylated therapeutic protein was used for LC/MS/MS-based detection and quantitation. A protein and a peptide were used as internal standards, with the former added before the sample extraction and the latter after the sample extraction. The method developed is simple, sensitive, specific and rugged, and has been implemented in a high throughput 96-well format to analyze plasma samples from in vivo studies. A required lower limit of quantitation (LLOQ) of 10 ng/mL, expressed in terms of the concentration of the protein drug, was easily achieved.  相似文献   

18.
Large-pore-size agarose gels provide excellent resolving capacity for high molecular weight biomolecules. Thin-layer agarose isoelectric focusing (IEF) gels on polyester support films are especially useful for the separation of large proteins based on their pI in native conformation, but the method has suffered from the lack of detection methods compatible with agarose gels in hydrated form. Recently, an acrylamide copolymerization method was reported to enable mass-spectrometry-compatible silver staining and in-gel digestion of proteins. In this study, the method was further applied by demonstrating successful reverse imidazole-zinc staining of thin-layer agarose IEF gels copolymerized with acrylamide. The sensitivity of the reverse staining method on the composite gel at its best equaled the sensitivity of the traditional dried agarose silver staining method. Owing to the increased durability and reversible detection, the reverse-stained first-dimension gel could be conveniently prepared for the second-dimension sodium dodecyl sulfate polyacrylamide gel electrophoresis by reduction and alkylation. In addition, the micropreparative generation of tryptic peptides of Coomassie brilliant blue R-250 stained proteins in the composite gel is demonstrated.  相似文献   

19.
An immediately applicable variant of the sequencing by hybridization (SBH) method is under development with the capacity to determine up to 100 million base pairs per year. The proposed method comprises six steps: (i) arraying genomic or cDNA M13 clones in 864-well plates (wells of 2 mm); (ii) preparation of DNA samples for spotting by growth of the M13 clones or by polymerase chain reaction (PCR) of the inserts using standard 96-well plates, or plates having as many as 864 correspondingly smaller wells; (iii) robotic spotting of 13,824 samples on an 8 x 12 cm nylon membrane, or correspondingly more, on up to 6 times larger filters, by offset printing with a 96 or 864 0.4 mm pin device; (iv) hybridization of dotted samples with 200-2000 32P-labeled probes comprising 16-256 10-mers having a common 8-mer, 7-mer, or 6-mer in the middle (20 probes per day, each hybridized with 250,000 dots); (v) scoring hybridization signals of 5 million sample-probe pairs per day using storage phosphor plates; and (vi) computing clone order and partial-to-complete DNA sequences using various heuristic algorithms. Genome sequencing based on a combination of this method and gel sequencing techniques may be significantly more economical than gel methods alone.  相似文献   

20.
In this study, a temperature-induced phase fractionation known as cloud-point extraction (CPE) with the non-ionic surfactant Triton X-114 was used to simultaneously extract, concentrate, and fractionate hydrophobic and hydrophilic proteins from mouse brain tissue. Two bottom-up proteomic techniques were used to comprehensively identify the extracted proteins. The first “shotgun”-based approach included tryptic digestion of the proteins followed by reversed-phase nanoliquid chromatography (RP-nanoLC) in combination with electrospray ionization (ESI) tandem mass spectrometry (MS/MS). In the second approach, the extracted intact proteins were first separated by one-dimensional (1D) gel electrophoresis and then in-gel digested with trypsin and analyzed with nanoLC-MS/MS. In total, 1,825 proteins were unambiguously identified and the percentage of membrane proteins was 26% which is at the reported genome expression levels of 20–30%. The protein overlap between the two approaches was high. The majority (77%) of the identifications in the first approach was also found by the second method. The protein overlap between the CPE-extracted hydrophilic and hydrophobic fractions was rather small (16–23%) for both methods, which indicates a good phase separation. A quantitative evaluation of the CPE with iTRAQ labeling and nanoLC-ESI-MS/MS analysis gave iTRAQ ratios at the expected levels and an overall variation of the entire method at 17–31%. The results indicate very reproducible sample preparation and analysis methods that readily can be applied on large-scale sample sets.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号