1.
A novel needle-type sample preparation device was developed for the effective preconcentration of volatile organic compounds (VOCs) in indoor air before gas chromatography–mass spectrometry (GC–MS) analysis. To develop a device for extracting a wide range of VOCs typically found in indoor air, several types of particulate sorbents were tested as the extraction medium in the needle-type extraction device. To determine the content of these VOCs, air samples were collected for 30 min with the packed sorbent(s) in the extraction needle, and the extracted VOCs were thermally desorbed in a GC injection port by the direct insertion of the needle. A double-bed sorbent consisting of a needle packed with divinylbenzene and activated carbon particles exhibited excellent extraction and desorption performance and adequate extraction capacity for all the investigated VOCs. The results also clearly demonstrated that the proposed sample preparation method is a more rapid, simpler extraction/desorption technique than traditional sample preparation methods.  相似文献   

2.
The FLEC®-SPME sampler, described in a previous paper, consists of an emission cell coupled with solid phase microextraction (SPME) for passive sampling of VOCs emitted from building materials. It represents an interesting alternative to standard dynamic sampling protocol as it is easier to implement. If standard dynamic sampling determines emission rates, passive FLEC®-SPME aims to the determination of the concentration in air at the material surface. That could be assumed provided that material/air equilibrium is reached. Thus, VOCs emission kinetics were studied for 3 different materials (pine wood panel, carpet and PVC floor) to determine equilibrium times. Then, the relevance of the method has been assessed using new materials through a 3-day emission test. Qualitative results were compared to those obtained from the standard method to check the ability of FLEC®-SPME to detect the most toxic compounds, named “VOCs of interest” and listed in the French regulation. Minor differences were observed, so this methodology seems promising, especially for field studies aiming in the identification of VOCs sources in buildings. Moreover, the concentration at the material surface combined to emission modeling could be used to predict indoor VOCs concentrations helping in indoor air quality diagnostic.  相似文献   

3.
室内空气中挥发性有机化合物污染及检测方法   总被引:8,自引:0,他引:8  
室内空气中挥发性有机污染物的释放严重影响了室内空气质量,本文较详细的叙述了这些有机污染物的来源、种类及处理方法等,并对空气中VOCs的采集和检测方法作以介绍,阐述了不同机制的热解吸仪与气相色谱联用时的优缺点及其应用.  相似文献   

4.
5.
This article reviews recent literature on the analysis of industrial contaminants in indoor air in the framework of the REACH project, which is mainly intended to improve protection of human health and the environment from the risks of more than 34 millions of chemical substances. Industrial pollutants that can be found in indoor air may be of very different types and origin, belonging to the volatile organic compounds (VOCs) and semivolatile organic compounds (SVOCs) categories. Several compounds have been classified into the priority organic pollutants (POPs) class such as polychlorinated biphenyls (PCBs), polychlorinated dibenzo-p-dioxins and furans (PCDD/PCDFs) and related polychlorinated compounds, and polycyclic aromatic hydrocarbons (PAHs). Many of these compounds are partially associated to the air gas phase, but also to the suspended particulate matter. Furthermore, settled dust can act as a concentrator for the less volatile pollutants and has become a matrix of great concern for indoors contamination. Main literature considered in this review are papers from the last 10 years reporting analytical developments and applications regarding VOCs, aldehydes and other carbonyls, PCBs, PCDDs, PCDFs, and PAHs in the indoor environment. Sample collection and pretreatment, analyte extraction, clean-up procedures, determination techniques, performance results, as well as compound concentrations in indoor samples, are summarized and discussed. Emergent contaminants and pesticides related to the industrial development that can be found in indoor air are reviewed in a second part in this volume.  相似文献   

6.
A novel Hadamard transform-gas chromatography/mass spectrometry (HT-GC/MS) system equipped with on-line sample collection systems is described. A Hadamard-injector was successfully designed and then coupled with an on-line adsorption/desorption system for detecting volatile organic compounds (VOCs) and a supercritical fluid extraction (SFE) system, respectively, by HT-GC/MS. Six VOCs and three pesticides were used as model compounds. In the former case, an activated-charcoal trap was used to trap VOCs from the indoor air. After 10 L of indoor air had passed through the trap, the condensed components were heated and simultaneously injected into the GC column through the Hadamard-injector, based on Hadamard codes. In a second experiment, a sample of rice was spiked with three types of pesticides and the sample then extracted using a commercially available supercritical fluid extractor. After extraction, the extracted components were transferred to a holding tank and simultaneously injected into the GC column also using the Hadamard-injector. The findings show that, in both cases, the combination of on-line sample collection methods and the use of the Hadamard transform resulted in improved sensitivity and detection. Compared to the single injection used in most GC/MS systems, the signal-to-noise (S/N) ratios were substantially improved after inverse Hadamard transformation of the encoded chromatogram.  相似文献   

7.
Gong X  Xiong X  Peng Y  Yang C  Zhang S  Fang X  Zhang X 《Talanta》2011,85(5):2458-2462
A simple-structure, low-power, and low-cost low temperature plasma (LTP) ionization source, coupled with mass spectrometry, for the online detection of indoor volatile organic compounds (VOCs) has been constructed in this work. Air, instead of noble gases, was employed as the discharging and carrier gas. And a custom-built AC high-voltage power supply with a total power consumption of 5 W, frequency of 2-4 kHz, and amplitude around 1-5 kVp-p was used. This LTP source is a soft ionization source. The initial performance of the ionization source has been evaluated by ionizing samples including alcohols, ketones, aldehydes and aromatics. These compounds cover most of the common air pollutants concerning people's health. It is well known that those plasmas generated by dielectric barrier discharge (DBD) produce significant amount of metastable species and electrons with mean energies greater than several electronvolt, but minimal fragmentation was observed in our work. Protonated ions are the dominant product for the VOCs detected after the ionization process. Further work has been conducted to confirm the detection feature of this source. The results are promising enough to ensure the novel LTP ionization source as an effective tool for the online detection of indoor VOCs.  相似文献   

8.
Preoxidation for colorimetric sensor array detection of VOCs   总被引:1,自引:0,他引:1  
A disposable preoxidation technique that dramatically improves the detection and identification of volatile organic compounds (VOCs) by a colorimetric sensor array is reported. Passing a vapor stream through a tube packed with chromic acid on silica immediately before the colorimetric sensor array substantially increases the sensitivity to less-reactive VOCs and improves the limits of detection (LODs) ~300-fold, permitting the detection, identification, and discrimination of 20 commonly found indoor VOC pollutants at both their immediately dangerous to life or health (IDLH) and permissible exposure limit (PEL) concentrations. The LODs of these pollutants were on average 1.4% of their respective PELs.  相似文献   

9.
There is an ongoing probing of the role of chemicals in the indoor environment. The majority of potential target substances are so‐called very volatile, volatile, and semi‐volatile organic compounds (VVOCs, VOCs, and SVOCs). Depending on their physical properties and the mass transfer conditions, they are distributed in or between the gas phase, particle phase, settled house dust, surface films, clothing, and other fabrics as well as the exposed skin and hair of the occupants themselves. Therefore, inhalation, ingestion, and dermal uptake all must be considered as relevant pathways for exposure assessment in human habitats. Exposure to VVOCs, VOCs, and SVOCs can be estimated by measuring their concentrations in relevant indoor compartments or by determining the amounts of the target compounds and/or their metabolites in urine and blood. Assessing the various routes of exposure often requires a combination of sophisticated and interdisciplinary theoretical background and experimental techniques. Consequently, close communication and collaboration between chemical and exposure scientists are needed to achieve a better understanding of human exposure to chemical substances in various indoor environments. Embedded in the toxicological context, this is the basis for assessing the corresponding health risks and for determining control strategies or approaches to limit such risks.  相似文献   

10.
A sensitive and reliable method is described for the determination of aromatic and chlorinated hydrocarbons (benzene, toluene, o-, m-, p-xylene, trichloromethane, trichloroethane, trichloroethene and tetrachloroethene) in indoor and outdoor air at environmental concentration levels. The procedure can be easily extended to other VOCs. Using passive samplers the VOCs have been adsorbed onto charcoal during a four-week sampling period and subsequently desorbed with carbon disulfide. After injection with a cold split-splitless multi-injector the VOCs have been separated by capillary gas chromatography. Quantification has been achieved using an electron capture detector (ECD) and a flame ionization detector (FID) switched in series. A limit of about 1 g/m3 for aromatic hydrocarbons and of about 0.01 g/m3 for chlorinated hydrocarbons has been obtained. The procedure has been successfully applied in the framework of a field study to measure indoor and outdoor air concentrations in Essen and Borken, two differently polluted areas of Northrhine-Westphalia.  相似文献   

11.

Background

A sampling campaign of indoor air was conducted to assess the typical concentration of indoor air pollutants in 8 National Libraries and Archives across the U.K. and Ireland. At each site, two locations were chosen that contained various objects in the collection (paper, parchment, microfilm, photographic material etc.) and one location was chosen to act as a sampling reference location (placed in a corridor or entrance hallway).

Results

Of the locations surveyed, no measurable levels of sulfur dioxide were detected and low formaldehyde vapour (< 18???g?m-3) was measured throughout. Acetic and formic acids were measured in all locations with, for the most part, higher acetic acid levels in areas with objects compared to reference locations. A large variety of volatile organic compounds (VOCs) was measured in all locations, in variable concentrations, however furfural was the only VOC to be identified consistently at higher concentration in locations with paper-based collections, compared to those locations without objects. To cross-reference the sampling data with VOCs emitted directly from books, further studies were conducted to assess emissions from paper using solid phase microextraction (SPME) fibres and a newly developed method of analysis; collection of VOCs onto a polydimethylsiloxane (PDMS) elastomer strip.

Conclusions

In this study acetic acid and furfural levels were consistently higher in concentration when measured in locations which contained paper-based items. It is therefore suggested that both acetic acid and furfural (possibly also trimethylbenzenes, ethyltoluene, decane and camphor) may be present in the indoor atmosphere as a result of cellulose degradation and together may act as an inferential non-invasive marker for the deterioration of paper. Direct VOC sampling was successfully achieved using SPME fibres and analytes found in the indoor air were also identified as emissive by-products from paper. Finally a new non-invasive, method of VOC collection using PDMS strips was shown to be an effective, economical and efficient way of examining VOC emissions directly from the pages of a book and confirmed that toluene, furfural, benzaldehyde, ethylhexanol, nonanal and decanal were the most concentrated VOCs emitted directly from paper measured in this study.  相似文献   

12.
Competitive adsorption on adsorptive solid-phase microextraction (SPME) fibres implies careful determination of operating conditions for reliable quantitative analysis of VOCs in indoor air. With this objective, two analytical approaches, involving non-equilibrium and equilibrium extraction, were compared. The average detection limit obtained for GC-MS analysis of nine VOCs by the equilibrium method is 0.2 μg m−3, compared with 1.9 μg m−3 with the non-equilibrium method. The effect of the relative humidity of the air on the calibration plots was studied, and shown to affect acetone adsorption only. Hence, the concentrations that can be accurately determined are up to 9 μmol m−3. The methods were then applied to indoor air containing different concentrations of VOCs. The non-equilibrium method, involving short extraction time, can be used for detection of pollution peaks whereas equilibrium extraction is preferable for measurement of sub-μg m−3 ground concentration levels.   相似文献   

13.
Here we put forward for the first time that the negative effect of humidity on CO photooxidation at room temperature can be overcome by adjusting the composition of Pd-Pt bimetallic particles supported on TiO(2). Consequently, optimized Pd(x)Pt(1-x)/TiO(2) materials can be considered as common and efficient photocatalysts for simultaneous elimination of CO and VOCs in the presence of humidity, i.e. for real indoor air treatment.  相似文献   

14.
Field air analysis with SPME device   总被引:5,自引:0,他引:5  
Solid-phase microextraction (SPME) devices were used for a wide scope of air-monitoring including field sampling and analysis of volatile organic compounds (VOCs), formaldehyde, and particulate matter (PM) in air. Grab (instantaneous) and time-weighted average (TWA) sampling were accomplished using exposed and retracted SPME fibers, respectively. Sampling time varied from 1 to 75 min, followed by analysis with a gas chromatograph (GC). A portable GC equipped with unique, in-series detectors: photoionization (PID), flame ionization (FID), and dry electrolytic conductivity (DELCD), provided almost real-time analysis and speciation for common VOCs during an indoor air quality surveys. Indoor air samples collected with SPME devices were compared with those collected using conventional National Institute for Occupational Safety and Health (NIOSH) methods. Air concentrations measured with the SPME device were as low as 700 parts-per-trillion (ppt) for semi-volatile organic compounds. SPME methodology proved to be more sensitive than conventional methods, and provided a simple approach for fast, cost-effective sampling and analysis of common VOCs in indoor air. SPME technology combined with fast portable GC reduced the sampling and analysis time to less than 15 min. The configuration offered the conveniences of immediate on-site monitoring and decision making, that are not possible with conventional methods. In addition, SPME fibers were applied to sampling of particulate matter in diesel engine exhaust. Linear uptake and particulate build-up on the fiber were observed. Preliminary research suggests that SPME fibers could also be applied to sampling of airborne particulate matter.  相似文献   

15.
A convenient analytical method to quantify volatile organic compounds (VOCs) emitted from various building materials has not been addressed yet. This work presents a new and rapid automated method using SPME combined with GC/MS. Methyl benzoate - as a metabolic biomarker for mold growth-was used to indicate VOCs and to determine and assess mold growth on damp samples. Gypsum board and wall-board paper were used as examples of common indoor building materials. Optimized extraction conditions were carried out manually, using a GC/flame ionization detector. Moldy samples were analyzed using an automated SPME-GC/MS analysis under optimized conditions. The amount of methyl benzoate emitted from the studied samples ranged from 32 to 46 ppb, where the density of the fungal biomass was found to be 8 x 10(4) cells/mL. A relationship between the amount of fungal biomass and the emitted concentration of methyl benzoate was found and assessed based upon cultured mold samples taken from indoor building sites. The analytical method shows promise for the compound methyl benzoate, which can easily be identified at low detection limits (LOD = 3 ppb) and good linearity (>0.988), and its extraction and detection can be accomplished cleanly by current extraction techniques. Results suggest that this method with easy sample preparation can be used for quantitation and, of importance, minimal matrix effects are observed.  相似文献   

16.
A novel adsorbent, 3-amino-propylsilica gel-multi-walled carbon nanotubes (APSG-MW), was prepared by chemical bonding multi-walled carbon nanotubes on silica gel. The surface area of APSG-MW was 98 m2/g, and the particle size was between 60 and 80 mesh with the average size of 215.0 μm. The adsorption capability of the new adsorbent to volatile organic compounds (VOCs) was measured. The effect of water to the adsorbent and its stability during storage were also investigated. Duplicate precision (DP) and distributed volume pair (DVP) on the basis of the EPA TO-17 criteria were estimated. The results showed that the sampling precision of the adsorbent was more superior compared to the MWCNTs because of the better air permeability. The new adsorbent was successfully applied in the determination of VOCs in ambient indoor air.  相似文献   

17.
The investigation of air pollution is a highly important field of research. Air quality in a vehicle’s interior has attracted growing attention since people spend much of their time in vehicles and those frequently travelling in new cars are exposed to harmful compounds. The main air pollutants inside new vehicles are volatile organic compounds (VOCs), present as a result of interior materials’ de-gassing. Among the sampling methods used in indoor air quality research, active sampling for VOCs collection is one method that has been extensively described and applied. The present study sought to implement passive sampling with Radiello® samplers to collect air samples directly in the car factory. The results from passive sampling were compared with results derived from active sampling using Carbograph 1TD and silicagel coated with 2,4-dinitrophenylhydrazine cartridges, based on previously validated methods. The identification and quantification of organic compounds was performed using gas chromatography with flame ionisation coupled with a mass spectrometer after thermal desorption. Aldehydes were determined by means of high-performance liquid chromatography. In the present study, the results obtained with the use of active and passive methods of air sampling were compared, correlations between the two sampling methods were designated and the repeatability of passive sampling was detailed.  相似文献   

18.
W-doped TiO(2) nanofibers with various compositions (W/Ti: 2-8%) were fabricated by the electrospinning method from respective precursor solutions containing tungsten(V) pentaethoxide, titanium tetraisopropoxide (TTIP), and polyvinylpyrrolidone (PVP), followed with calcination at 550 °C. Morphological and structural characteristics of these nanofibers were studied with SEM, XRD and XPS. W-doping inhibited the crystal growth and anatase-to-rutile transformation of TiO(2) nanofibers. W-doped TiO(2) nanofiber mats showed good photocatalytic oxidation abilities for acetone. Obvious color change from white to blue of mats during the photocatalysis process can be detected by naked eyes, which provides a good way in detection of pollutants in indoor air, especially for the volatile organic compounds (VOCs).  相似文献   

19.
Solid-phase microextraction (SPME) is a powerful technique, easy to implement for on-site static sampling of indoor VOCs emitted by building materials. However, a major constraint lies in the establishment of calibration curves which requires complex generation of standard atmospheres. Thus, the purpose of this paper is to propose a model to predict adsorption kinetics (i.e., calibration curves) of four model VOCs. The model is based on Fick’s laws for the gas phase and on the equilibrium or the solid diffusion model for the adsorptive phase. Two samplers (the FLEC? and a home-made cylindrical emission cell), coupled to SPME for static sampling of material emissions, were studied. A good agreement between modeling and experimental data is observed and results show the influence of sampling rate on mass transfer mode in function of sample volume. The equilibrium model is adapted to quite large volume sampler (cylindrical cell) while the solid diffusion model is dedicated to small volume sampler (FLEC?). The limiting steps of mass transfer are the diffusion in gas phase for the cylindrical cell and the pore surface diffusion for the FLEC?. In the future, this modeling approach could be a useful tool for time-saving development of SPME to study building material emission in static mode sampling.  相似文献   

20.
Sin DW  Wong YC  Sham WC  Wang D 《The Analyst》2001,126(3):310-321
A technique using Summa canisters with cryogenic preconcentration and gas chromatographic-mass spectrometric (GC-MS) detection was developed to determine 143 C3-C12 volatile organic compounds (VOCs) including alkanes, alkenes, aromatics and halohydrocarbons in ambient and indoor air. The method detection limits and practical quantification limits were sensitive at 0.02 and 0.10 ppbv, respectively, and the method precision and accuracy were also satisfactory. The stability of C3-C12 VOC standards at ppbv levels under elevated pressure in canisters was assessed over various time intervals (from 1 week to 4 months after preparation) and most of the compounds were found to be acceptably stable with a mean recovery of 85.6 +/- 9.9% during the course of a 4-month study. However, a small fraction (approximately 6%) of the compounds, including two halohydrocarbons (bromotrichloromethane and benzyl chloride) and six alkenes (2-methylbuta-1,3-diene (isoprene), cis-4-methylpent-2-ene, cis-3-methylpent-2-ene, hept-1-ene, oct-1-ene and styrene) displayed relatively low recoveries in the range 34.6-67.9%. The loss of these compounds is most probably caused by their physical adherence to the active sites of the canister surface, chemical decomposition and/or reactions with other species. The results indicated that one must be cautious in attempting to measure these compounds owing to their instability in canisters. Overall, this analytical technique, which has been used for the determination of the VOCs under study in the toxic air pollutant monitoring network administered by the HKSAR Government, was amenable to the measurement of airborne VOCs collected both outside and inside a semi-confined car park in the present study.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号