1.

Purpose

This study aimed to develop a 0.014-in., anti-solenoid loop (ASL) magnetic resonance imaging guidewire (MRIG) for intravascular 3.0-T MR imaging.

Materials and Methods

We first designed the ASL MRIG, which was made of a coaxial cable with its extended inner conductor and outer conductor connected to two micro-anti-solenoids. We then evaluated in vitro the functionality of the ASL MRIG by imaging a “vessel” in a phantom and achieving signal-to-noise ratio (SNR) and SNR contour map of the new 0.014-in. ASL MRIG. Subsequently, we validated in vivo the feasibility of using the ASL MRIG to generate intravenous 3.0-T MR images of parallel iliofemoral arteries of near-human-sized living pigs.

Results

In vitro evaluation showed that the 0.014-in. ASL MRIG functioned well as a receiver coil with the 3.0-T MR scanner, clearly displaying the vessel wall with even distribution of MR signals and SNR contours from the ASL MRIG. Of the in vivo studies, the new ASL MRIG enabled us to successfully generate intravenous 3.0-T MR imaging of the iliofemoral arteries.

Conclusion

This study confirms that it is possible to build such small-looped MRIG at 0.014 in. for intravascular 3.0-T MR imaging.  相似文献   

2.

Aim

To study the effect of long-term glucose feeding on aortic lipid composition by using the time of flight-secondary ion mass spectrometry (TOF-SIMS).

Method

Rats were divided into two groups, drinking water with or without 10% glucose from birth to 6 months of age. The aortic wall was dissected out, high-pressure frozen, freeze-fractured, freeze-dried and analyzed by TOF-SIMS using a Bismuth cluster ion source. Surface spectra were taken from standardized regions of the vessel wall.

Results

Different peaks, such as cholesterol, fatty acids (FAs) and diacylglycerols (DAGs), were identified by the principal component analysis as carries of variance between two groups. These peaks were then compared by conventional t-test. Our data showed that the intensity of cholesterol, but not FAs and DAGs, was significantly decreased in the glucose-drinking rat. Moreover, the long-term glucose intake changed ratios between different FAs in the aorta.

Conclusion

The long-term glucose intake led to decreased cholesterol intensity in the aortic wall and this effect was revealed through a global analytical approach with objective selection of significant variables.  相似文献   

3.
Shen CC  Wu HH 《Ultrasonics》2012,52(2):238-243

Background

High-frequency Doppler imaging is highly potential for detection of blood flow in microcirculation. In a swept-scan system, however, the spectral broadening of tissue clutter limits the detectability of low-velocity flow signal. Conventionally, the scanning speed of transducer has to be reduced to alleviate the clutter interference but at the cost of imaging frame rate. For example, the blood velocity of 0.5 mm/s becomes detectable only with a scanning speed lower than 1 mm/s. In this study, an alternative method is examined by suppressing the clutter magnitude to reduce the interference to flow signal without sacrificing scanning speed.

Methods

The method of third harmonic (3f0) transmit phasing can suppress the tissue harmonic clutter by transmitting at the fundamental and the additional 3f0 frequencies to achieve mutual cancellation between the frequency-sum and the frequency-difference components of the second harmonic signal. With 3f0 transmit phasing, the cut-off frequency of wall filtering can be reduced to preserve low-velocity flow without compromising the frame rate.

Results

Our results indicate that the 3f0 transmit phasing effectively reduces the harmonic clutter magnitude and thus improves the flow signal-to-clutter ratio. Compared to the conventional counterpart, the clutter-suppressed color flow and power Doppler images show fewer clutter artifacts and is capable of detecting more low-velocity flow of microbubbles. The resultant color-pixel-density also improves with clutter suppression.

Conclusion

For the swept-scan high-frequency (>20 MHz) system, 3f0 transmit phasing is capable of providing effective clutter suppression. With the same achievable scanning speed, the resultant Doppler image has higher sensitivity for low-velocity flow and is less susceptible to clutter artifacts.  相似文献   

4.

Purpose

The purpose of the study was to investigate the relationship between gas challenge-blood oxygen level-dependent (GC-BOLD) response angiogenesis and tumor size in rat Novikoff hepatoma model.

Materials and Methods

Twenty adult male Sprague-Dawley rats (weighting 301-325 g) were used for our Animal Care and Use Committee-approved experiments. N1-S1 Novikoff hepatomas were grown in 14 rats with sizes ranging from 0.42 to 2.81 cm. All experiments were performed at 3.0 T using a custom-built rodent receiver coil. A multiple gradient-echo sequence was used for R2? measurements, first during room air (78% N2/20% O2) breathing and then after 10 min of carbogen (95% O2/5% CO2) breathing. After image acquisition, rats were euthanized, and the tumors were harvested for histological evaluation.

Results

The R2? change between air and carbogen breathing for small hepatomas was positive; R2? changes changed to negative values for larger hepatomas. We found a significant positive correlation between tumor R2? change and tumor microvessel density (MVD) (r=0.798, P=.001) and a significant inverse correlation between tumor R2? change and tumor size (r=−0.840, P<.0001).

Conclusions

GC-BOLD magnetic resonance imaging measurements are well correlated to MVD levels and tumor size in the N1-S1 Novikoff hepatoma model; GC-BOLD measurements may serve as noninvasive biomarkers for evaluating angiogenesis and disease progression and/or therapy response.  相似文献   

5.

Objective:

The objective in this work is to investigate the feasibility of using a new imaging tool called vibro-acoustography (VA) as a means of permanent prostate brachytherapy (PPB) seed localization to facilitate post-implant dosimetry (PID).

Methods and materials:

Twelve OncoSeed (standard) and eleven EchoSeed (echogenic) dummy seeds were implanted in a human cadaver prostate. Seventeen seeds remained after radical retropubic prostatectomy. VA imaging was conducted on the prostate that was cast in a gel phantom and placed in a tank of degassed water. 2-D magnitude and phase VA image slices were obtained at different depths within the prostate showing location and orientation of the seeds.

Results:

VA demonstrates that twelve of seventeen (71%) seeds implanted were visible in the VA image, and the remainder were obscured by intra-prostatic calcifications. Moreover, it is shown here that VA is capable of imaging and locating PPB seeds within the prostate independent of seed orientation, and the resulting images are speckle free.

Conclusion:

The results presented in this research show that VA allows seed detection within a human prostate regardless of their orientation, as well as imaging intra-prostatic calcifications.  相似文献   

6.

Objective

Perfluorocarbon-exposed sonicated dextrose albumin microbubbles (PESDA) binds scavenger receptors and can be noninvasively imaged. To enhance imaging, gadolinium (Gd)-labeled PESDA was developed and tested in a model of vascular inflammation by magnetic resonance imaging (MRI).

Methods and Results

Purified human serum albumin (HSA) (5%) was labeled with Gd via the covalent binding of diethylenetriaminepentacetic acid. Abdominal aortic tissues in Sprague-Dawley rats (n=5 per group) were analyzed by 7-T MRI and scanning electron microscopy to evaluate PESDA binding. Labeling-purified 5% human albumin resulted in an average of 16.1 Gd atoms per albumin molecule as determined by atomic absorption. Forty-eight hours after balloon angioplasty, aortic tissue was enhanced with Gd-PESDA as compared to control tissue. 7-T MRI of explanted tissues was sensitive to the detection of retained PESDA. Enhancement of aortic tissue in vivo was present albeit to a lesser extent than explanted tissue from the same animals.

Conclusions

HSA was successfully labeled, and an albumin-based microbubble with Gd was synthesized. This contrast agent, Gd-PESDA, may serve as an additional agent for the MRI evaluation of innate inflammation and used to noninvasively image early vascular pathophysiologic processes.

Condensed Abstract

In this study, Gd-PESDA microbubbles and were synthesized and shown to detect the binding of these microbubbles using MRI in injured aortic tissue. The method for synthesizing Gd-PESDA is detailed, and the proposed utility of this new contrast agent is discussed.  相似文献   

7.

Background

Cardiac magnetic resonance imaging (CMR) can accurately determine infarct size. Prior studies using indirect methods to assess infarct size have shown that patients with larger myocardial infarctions have a worse prognosis than those with smaller myocardial infarctions.

Objectives

This study assessed the prognostic significance of infarct size determined by CMR.

Methods

Cine and contrast CMR were performed in 100 patients with coronary artery disease (CAD) undergoing routine cardiac evaluation. Infarct size was determined by planimetry. We used Cox proportional hazards regression analyses (stepwise forward selection approach) to evaluate the risk of all-cause death associated with traditional cardiovascular risk factors, symptoms of heart failure, medication use, left ventricular ejection fraction, left ventricular mass, angiographic severity of CAD and extent of infarct size determined by CMR.

Results

Ninety-one patients had evidence of myocardial infarction by CMR. Mean follow-up was 4.8±1.6 years after CMR, during which time 30 patients died. The significant multivariable predictors of all-cause mortality were extent of myocardial infarction by CMR, extent of left ventricular systolic dysfunction, symptoms of heart failure, and diabetes mellitus (P<.05). The presence of infarct greater than or equal to 24% of left ventricular mass and left ventricular ejection fraction less than or equal to 30% were the most optimal cut-off points for the prediction of death with bivariate adjusted hazard ratios of 2.11 (95% confidence interval 1.02-4.38) and 4.06 (95% confidence interval 1.73-9.54), respectively.

Conclusions

The extent of myocardial infarction determined by CMR is an independent predictor of death in patients with CAD.  相似文献   

8.

Purpose

The objective of this paper was to automatically segment the cerebellum from T1-weighted human brain magnetic resonance (MR) images.

Materials and Methods

The proposed method constructs a cerebellum template using five sets of 3-T MR imaging (MRI) data, which are used to determine the initial position and the shape prior of the cerebellum for the active contour model. Our formulation includes the active contour model with shape prior, which thereby maintains the shape of the template. The proposed active contour model is sequentially applied to sagittal-, coronal- and transverse-view images. To evaluate the proposed method, it is applied to BrainWeb data and a 3-T MRI data set and compared with FreeSurfer with respect to performance assessment metrics.

Results

The segmented cerebellum was compared with the results from FreeSurfer. Using the manually segmented cerebellum as reference, we measured the average Jaccard coefficients of the proposed method, which were 0.882 and 0.885 for the BrainWeb data and 3-T MRI data set, respectively.

Conclusion

We presented the active contour model with shape prior for extracting the cerebellum from T1-weighted brain MR images. The proposed method yielded a robust and accurate segmentation result.  相似文献   

9.

Background

Measurement of surface roughness irregularities that result from various sources such as manufacturing processes, surface damage, and corrosion, is an important indicator of product quality for many nondestructive testing (NDT) industries. Many techniques exist, however because of their qualitative, time-consuming and direct-contact modes, it is of some importance to work out new experimental methods and efficient tools for quantitative estimation of surface roughness.

Objective and method

Here we present continuous-wave ultrasound reflectometry (CWUR) as a novel nondestructive modality for imaging and measuring surface roughness in a non-contact mode. In CWUR, voltage variations due to phase shifts in the reflected ultrasound waves are recorded and processed to form an image of surface roughness.

Results

An acrylic test block with surface irregularities ranging from 4.22 μm to 19.05 μm as measured by a coordinate measuring machine (CMM), is scanned by an ultrasound transducer having a diameter of 45 mm, a focal distance of 70 mm, and a central frequency of 3 MHz. It is shown that CWUR technique gives very good agreement with the results obtained through CMM inasmuch as the maximum average percent error is around 11.5%.

Conclusion

Images obtained here demonstrate that CWUR may be used as a powerful non-contact and quantitative tool for nondestructive inspection and imaging of surface irregularities at the micron-size level with an average error of less than 11.5%.  相似文献   

10.

Objective

To determine whether metabolite ratios in multivoxel 3D proton MR spectroscopy (1H MRS) is different between low-grade and high-grade gliomas and may be useful for glioma grading.

Materials and Methods

Thirty-nine patients (23 male and 16 female; 22-75 years old; mean age, 44.92±12.65 years) suspected of having gliomas underwent 3D 1H MRS examinations. Metabolite ratios [choline (Cho)/creatine (Cr), N-acetylaspartate (NAA)/Cr and Cho/NAA] were measured. Tumor grade was determined by using the histopathologic grading. Receiver operating characteristic analysis of metabolite ratios was performed, and optimum thresholds for tumor grading were determined. The resulting sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) for identifying high-grade gliomas were calculated.

Results

Diagnostic-quality 3D 1H MRS with readily quantifiable Cho, Cr and NAA peaks was obtained in 94.87% of the cases. The Cho/Cr and Cho/NAA ratios were significantly higher in high-grade than in low-grade glioma (P<.001), whereas the NAA/Cr ratios were significantly lower in high-grade than in low-grade glioma (P<.001). Receiver operating characteristic analysis demonstrated a threshold value of 2.04 for Cho/Cr ratio to provide sensitivity, specificity, PPV and NPV of 84.00%, 83.33%, 91.30% and 71.43%, respectively. Threshold value of 2.20 for Cho/NAA ratio resulted in sensitivity, specificity, PPV and NPV of 88.00%, 66.67%, 84.62% and 72.73%, respectively. Overall diagnostic accuracy was not statistically significantly different between Cho/Cr and Cho/NAA ratios (χ2=0.093, P=.76).

Conclusion

Metabolite ratios of low-grade gliomas were significantly different from high-grade gliomas. Cho/Cr and Cho/NAA ratios could have the superior diagnostic performance in predicting the glioma grade.  相似文献   

11.

Objectives

Curcumin, a natural pigment from the traditional Chinese herb, has shown promise as an efficient enhancer of ultrasound. The present study aims to investigate ultrasound-induced cellular destruction of nasopharyngeal carcinoma cells in the presence of curcumin in vitro.

Methods

Nasopharyngeal carcinoma cell line CNE2 cells were incubated by 10 μm curcumin and then were treated by ultrasound for 8 s at the intensity of 0.46 W/cm2. Cytotoxicity was evaluated using MTT assay and light microscopy. Mitochondrial damage was analyzed using a confocal laser scanning microcopy with Rhodamine 123 and ultrastructural changes were observed using a transmission electron microscopy (TEM).

Results

MTT assay showed that cytotoxicity induced by ultrasound treatment alone and curcumin treatment alone was 18.16 ± 2.37% and 24.93 ± 8.30%, respectively. The cytotoxicity induced by the combined treatment of ultrasound and curcumin significantly increased up to 86.67 ± 7.78%. TEM showed that microvillin disappearance, membrane blebbing, chromatin condensation, swollen mitochondria, and mitochondrial myelin-like body were observed in the cells treated by ultrasound and curcumin together. The significant collapse of mitochondrial membrane potential (MMP) was markedly observed in the CNE2 cells after the combined treatment of curcumin and ultrasound.

Conclusions

Our findings demonstrated that ultrasound sonication in the presence of curcumin significantly killed the CNE2 cells and induced ultrastructural damage and the dysfunction of mitochondria, suggesting that ultrasound treatment remarkably induced cellular destruction of nasopharyngeal carcinoma cells in the presence of curcumin.  相似文献   

12.

Purpose

The purpose of our study was to compare diffusion-weighted MR imaging (DWI) with conventional dynamic MRI in terms of the assessment of small intrahepatic metastases from hepatocellular carcinoma (HCC).

Materials and Methods

In 24 patients with multifocal, small (≤2 cm) intrahepatic metastatic foci of advanced HCC, a total of 134 lesions (≤1 cm, n=81; >1 cm, n=53) were subjected to a comparative analysis of hepatic MRI including static and gadopentetate dimeglumine-enhanced dynamic imaging, and DWI using a single-shot spin-echo echo-planar MRI (b values=50, 400 and 800 s/mm2), by two independent reviewers.

Results

A larger number of the lesions were detected and diagnosed as intrahepatic metastases on DWI [Reviewer 1, 121 (90%); Reviewer 2, 117 (87%)] than on dynamic imaging [Reviewer 1, 107 (80%); Reviewer 2, 105 (78%)] (P<.05). For the 81 smaller lesions (≤1 cm), DWI was able to detect more lesions than dynamic imaging [Reviewer 1, 68 (84%) vs. 56 (69%), P=.008; Reviewer 2, 65 (80%) vs. 55 (68%), P=.031], but there was no statistically significant difference between the two image sets for larger (>1 cm) lesions.

Conclusion

Due to its higher detection rate of subcentimeter lesions, DWI could be considered complementary to dynamic MRI in the diagnosis of intrahepatic metastases of HCCs.  相似文献   

13.

Introduction

The aim of the study was to evaluate the effects of TPU together with DMSO on oxidative stress parameters after eccentric exercise.

Methods

Thirty and six animals were divided in control; eccentric exercise (EE); EE + saline gel 0.9%; EE + TPU 0.8 W/cm2; EE + DMSO gel; EE + TPU + DMSO gel and submitted to one 90-min downhill run (1.0 km h−1). TPU was used 2, 12, 24, 46 h after exercise session and 48 h after the animals were killed and the gastrocnemius muscles were surgically removed. Production of superoxide anion, creatine kinase (CK) levels, lipoperoxidation, carbonylation, and antioxidants enzymes were analyzed.

Results

Showed that TPU and gel-DMSO improved muscle healing. Moreover, superoxide anion production, TBARS level and protein carbonyls levels, superoxide dismutase and catalase activity were all decreased in the group TPU plus gel-DMSO.

Discussion

Our results show that DMSO is effective in the reduction of the muscular lesion and in the oxidative stress after eccentric exercise only when used with TPU.  相似文献   

14.

Purpose

This retrospective study was designed to evaluate the apparent diffusion coefficient (ADC) of line scan diffusion images (LSDI) in normal prostate and prostate cancer. Single-shot echo planner images (SS-EPI) were used for comparison.

Materials and Methods

Twenty prostate tumors were examined by conventional MRI in 14 patients prior to radical prostatectomy. All patients were examined with a 1.5-T MR imager (Signa CV/i ver. 9.1 GE Medical System Milwaukee, WI, USA). Diffusion-weighted MR imaging (DWI) using LSDI was performed with a pelvic phased-array coil, with b values of 5 and 800 s/mm2. DWI using SS-EPI was performed with a body coil, with b values of 0 and 800 s/mm2. The ADCs of each sequence for 14 normal prostate and 20 prostate cancers were histopathologically assessed. Signal-to-noise ratio (SNR) on DWI was estimated and compared for each sequence.

Results

The mean ADCs (±S.D.) of normal peripheral zones (PZ), transition zones (TZ) and cancer (in 10−3 mm2/s) that used LSDI were 1.42±0.12, 1.23±0.10 and 0.79±0.19, respectively. Those that used SS-EPI were 1.76±0.26, 1.38±0.20 and 1.05±0.27, respectively. Using unpaired t test (P<.05), we found a significant difference in each sequence between normal tissue (both PZ and TZ) and the cancer. Paired t test (P<.05) also registered a significant difference between LSDI and SS-EPI. Mean SNR for DWI using LSDI was 16.49±5.03, while the DWI using SS-EPI was 18.85±9.26. The difference between the SNR of each sequence was not statistically significant by paired t test.

Conclusion

We found that ADCs using LSDI and SS-EPI showed similar tendencies in the same patients. However, in all regions, LSDI ADCs had smaller standard deviations than SS-EPI ADCs.  相似文献   

15.

Aim

The influences on the signal-to-noise ratio (SNR) of Displacement ENcoding with Stimulated Echoes (DENSE) MRI of field strength, receiver coil sensitivity and choice of flip angle strategy have been previously investigated individually. In this study, all of these parameters have been investigated in the same setting, and a mutual comparison of their impact on SNR is presented.

Materials and methods

Ten healthy volunteers were imaged in a 1.5 T and a 3 T MRI system, using standard five- or six-channel cardiac coils as well as 32-channel coils, with four different excitation patterns. Variation of spatial coil sensitivity was assessed by regional SNR analysis.

Results

SNR ranging from 2.8 to 30.5 was found depending on the combination of excitation patterns, coil sensitivity and field strength. The SNR at 3 T was 53±26% higher than at 1.5 T (P<.001), whereas spatial differences of 59±26% were found in the ventricle (P<.001). Thirty-two-channel coils provided 52±29% higher SNR compared to standard five- or six-channel coils (P<.001). A fixed flip angle strategy provided an excess of 50% higher SNR in half of the imaged cardiac cycle compared to a sweeping flip angle strategy, and a single-phase acquisition provided a sixfold increase of SNR compared to a cine acquisition.

Conclusion

The effect of field strength and receiver coil sensitivity influences the SNR with the same order of magnitude, whereas flip angle strategy can have a larger effect on SNR. Thus, careful choice of imaging hardware in combination with adaptation of the acquisition protocol is crucial in order to realize sufficient SNR in DENSE MRI.  相似文献   

16.

Introduction

Ultrasound mediated destruction of microbubbles (MBs) has become a promising tool for site specific drug and gene delivery. One of the most important properties of drug-loaded MBs is their destructibility by ultrasound. Therefore, the aim of this study was to establish a new in vitro model that allows evaluation of the kinetics of ultrasound-mediated MB destruction at near physiological conditions.In this work, a newly developed drug-loaded MB formulation was compared with unloaded MBs in order to assess the influence of drug-loading on their acoustic destructibility. Furthermore, drug-loaded MBs were compared to acoustically active lipospheres (AALs), comprising an additional layer of triacetin, as well as to a marketed MB contrast agent (SonoVue®, Bracco Diagnostics, USA), used as standard.

Methods

MBs with phospholipid monolayer shells were produced by mechanical agitation of liposomal dispersions and octafluoropropane gas. AALs were accordingly produced by agitation of phospholipid-stabilized aqueous triacetin microemulsions with gas.The in vitro experimental setup for acoustic destructibility testing comprised a membrane cell, pressurized and brought to 37 °C in order to imitate human blood pressure and body temperature. The optimized egg-like cell shape provided optimal flow conditions and a minimized dead volume.Ultrasound with frequencies of 1 and 3 MHz and intensities, varying from 1 to 4 W/cm2, was applied through a silicone membrane window to the cell. MB size distribution and concentration were measured by light blockage in equal time intervals during the sonication.

Results

The optimized in vitro setup demonstrated differences in the ultrasound destructibility of the MB formulations used. The fastest decay upon ultrasound exposure was found for SonoVue®. Unloaded and drug-loaded MBs appeared to be comparably destructible to SonoVue®. AALs were about 4.5-fold more stable than SonoVue®. MB destructibility was also found to depend on particle diameter, corresponding to theoretical models described in the literature.

Conclusion

The optimized in vitro setup has rendered a fast and reliable laboratory tool for characterization of MB formulations.  相似文献   

17.

Purpose

To establish the feasibility of chemical exchange saturation transfer (proteinCEST) MRI in the differentiation of osteoarthritis (OA) knee joints from non-OA joints by detecting mobile protein and peptide levels in synovial fluid by determining their relative distribution.

Materials and Methods

A total of 25 knees in 11 men and 12 women with knee injuries were imaged using whole knee joint proteinCEST MRI sequence at 3 T. The joint synovial fluid was segmented and the asymmetric magnetization transfer ratio at 3.5 ppm MTRasym (3.5 ppm) was calculated to assess protein content in the synovial fluid. The 85th percentile of synovial fluid MTRasym (3.5 ppm) distribution profile was compared using the independent Student's t test. The diagnostic performance of the 85th percentile of synovial fluid MTRasym (3.5 ppm) in differentiating OA and non-OA knee joints was evaluated.

Results

The 85th percentile of synovial fluid MTRasym (3.5 ppm) in knee joints with OA was 8.6%±3.4% and significantly higher than that in the knee joints without OA (6.3%±1.4%, P<.05). A knee joint with an 85th percentile of synovial fluid MTRasym (3.5 ppm) greater than 7.7% was considered to be an OA knee joint. With the threshold, the sensitivity, specificity and overall accuracy for differentiating knee joints with OA from the joints without OA were 54% (7/13), 92% (11/12) and 72% (18/25), respectively.

Conclusion

proteinCEST MRI appears feasible as a quantitative methodology to determine mobile protein levels in synovial fluid and identify patterns characteristic for OA disease.  相似文献   

18.

Purpose

A direct correlation between T, T2 and quantified proteoglycan and collagen contents in human osteoarthritic cartilage has yet to be documented. We aimed to investigate the orientation effect on T and T2 values in human osteoarthritic cartilage and to quantify the correlation between T, T2 vs. biochemical composition and histology in human osteoarthritic cartilage.

Materials and methods

Thirty-three cartilage specimens were collected from patients who underwent total knee arthroplasty due to severe osteoarthritis and scanned with a 3T MR scanner for T and T2 quantification. Nine specimens were scanned at three different orientations with respect to the B0: 0°, 90° and 54.7°. Core punches were taken after MRI. Collagen and proteoglycan contents were quantified using biochemical assays. Histology sections were graded using Mankin scores. The correlation between imaging parameters, biochemical contents and histological scores were studied.

Results

Both mean T and T2 at 54.7° were significantly higher than those measured at 90° and 0°, with T showing less increase compared to T2. R (1/T) values had a significant but moderate correlation with proteoglycan contents (R=.45, P=.002), while R2 (1/T2) was not correlated with proteoglycan. No significant correlation was found between relaxation times (T or T2) and collagen contents. The T values of specimen sections with high Mankin scores were significantly higher than those with low Mankin scores (P<.05).

Conclusions

Quantitative MRI has a great potential to provide noninvasive imaging biomarkers for cartilage degeneration in osteoarthritis.  相似文献   

19.
Huang QH  Lee SY  Liu LZ  Lu MH  Jin LW  Li AH 《Ultrasonics》2012,52(2):266-275

Objectives

This paper introduces a new graph-based method for segmenting breast tumors in US images.

Background and motivation

Segmentation for breast tumors in ultrasound (US) images is crucial for computer-aided diagnosis system, but it has always been a difficult task due to the defects inherent in the US images, such as speckles and low contrast.

Methods

The proposed segmentation algorithm constructed a graph using improved neighborhood models. In addition, taking advantages of local statistics, a new pair-wise region comparison predicate that was insensitive to noises was proposed to determine the mergence of any two of adjacent subregions.

Results and conclusion

Experimental results have shown that the proposed method could improve the segmentation accuracy by 1.5-5.6% in comparison with three often used segmentation methods, and should be capable of segmenting breast tumors in US images.  相似文献   

20.

Background

Permanent prostate brachytherapy (PPB) is a common treatment for early stage prostate cancer. While the modern approach using trans-rectal ultrasound guidance has demonstrated excellent outcome, the efficacy of PPB depends on achieving complete radiation dose coverage of the prostate by obtaining a proper radiation source (seed) distribution. Currently, brachytherapy seed placement is guided by trans-rectal ultrasound imaging and fluoroscopy. A significant percentage of seeds are not detected by trans-rectal ultrasound because certain seed orientations are invisible making accurate intra-operative feedback of radiation dosimetry very difficult, if not impossible. Therefore, intra-operative correction of suboptimal seed distributions cannot easily be done with current methods. Vibro-acoustography (VA) is an imaging modality that is capable of imaging solids at any orientation, and the resulting images are speckle free.

Objective and methods

The purpose of this study is to compare the capabilities of VA and pulse-echo ultrasound in imaging PPB seeds at various angles and show the sensitivity of detection to seed orientation. In the VA experiment, two intersecting ultrasound beams driven at f1 = 3.00 MHz and f2 = 3.020 MHz respectively were focused on the seeds attached to a latex membrane while the amplitude of the acoustic emission produced at the difference frequency 20 kHz was detected by a low frequency hydrophone.

Results

Finite element simulations and results of experiments conducted under well-controlled conditions in a water tank on a series of seeds indicate that the seeds can be detected at any orientation with VA, whereas pulse-echo ultrasound is very sensitive to the seed orientation.

Conclusion

It is concluded that vibro-acoustography is superior to pulse-echo ultrasound for detection of PPB seeds.  相似文献   