首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Preparation and characterization of microscopic biochemically active regions are important for the development of miniaturized bioanalytical systems with proteins, such as miniaturized enzyme electrode arrays. Scanning electrochemical microscopy (SECM) has emerged as an ideal tool for prototyping such systems. The technique is based on electrochemical conversions of dissolved species at a micrometer-sized probe electrode. It offers several mechanisms for local surface modifications under conditions compatible with conservation of protein functionality of enzymes and antibodies. The subsequent imaging of the immobilized activity provides direct information about local immobilized enzyme activities. The working modes of the techniques are illustrated by recent studies from this laboratory for the design and characterization of patterned enzyme layers covalently linked to gold surfaces via thiol self-assembly chemistry.  相似文献   

2.
Scanning electrochemical microscopy (SECM) was used to characterize enzyme-modified glass-gold specimens. The exposed gold surface was functionalized with an aminothiol and reacted with carbodiimide-activated glucose oxidase. The specimen surface was examined with SECM, using a 25 μm platinum electrode. Images were acquired showing the topography, electric conductivity, and enzymatic activity of the composite surface. It was found that the hydroxy-groups of the glass surface are as likely to bind to the activated enzyme as the amino-groups on the gold surface.  相似文献   

3.
The scanning electrochemical microscope (SECM) is used in the direct mode to draw patterns of a thin passivating organic layer on a gold electrode surface and to image them. The patterning is ensured by the local electrografting of the organic moieties obtained by reduction of an aryliodonium salt, as evidenced by XPS and SECM line scans. The resolution of the writing process is controlled by the charge injected.  相似文献   

4.
A local electrodeposition method was developed for chitosan by exploiting a pH gradient between a macroscopic electrode (the support) and a much smaller counter electrode. The deposition was confined either by using the direct mode of scanning electrochemical microscopy (SECM) or by performing the deposition in channels of a microfluidic network. The roughness was characterized by noncontact scanning force microscopy. The availability of amino groups at the surface of the microstructures was visualized after labeling by confocal laser scanning microscopy. The enzyme glucose oxidase could be entrapped during the electrochemical deposition and showed activity as seen by SECM images.  相似文献   

5.
This review summarizes the characterization of localized enzymatic activity by scanning electrochemical microscopy (SECM). After introducing the concepts of feedback imaging and generator-collector experiments with enzyme-modified solid surfaces, a comparison of the merits and limitations of both approaches is given and further illustrated by selected applications. They include enzyme-modified patterned monolayers, enzyme-modified polymer microstructures and enzyme-modified metal microstructures. Such configurations are important for the development of miniaturized bioanalytical systems with proteins, such as miniaturized enzyme electrode arrays. SECM has emerged as an ideal tool for prototyping of such systems. It also offers several mechanisms for local surface modifications under conditions compatible with conservation of protein functionality of enzymes and antibodies. The subsequent imaging of the immobilized activity provides direct information about local immobilized enzyme activity. The range of biotechnological applications can be expanded by labeling other biomolecules, such as monoclonal antibodies, with appropriate enzymes. Miniaturized electrochemical enzyme immunoassays that apply the sandwich format and SECM as the detection method are reviewed. They have been performed on microstructured supports after reagent spotting or on agglomerates of surface-modified magnetic microbeads. Finally, current challenges are listed with indications of ongoing research to overcome current limitations by means of instrumental improvements.  相似文献   

6.
This review summarizes the characterization of localized enzymatic activity by scanning electrochemical microscopy (SECM). After introducing the concepts of feedback imaging and generator-collector experiments with enzyme-modified solid surfaces, a comparison of the merits and limitations of both approaches is given and further illustrated by selected applications. They include enzyme-modified patterned monolayers, enzyme-modified polymer microstructures and enzyme-modified metal microstructures. Such configurations are important for the development of miniaturized bioanalytical systems with proteins, such as miniaturized enzyme electrode arrays. SECM has emerged as an ideal tool for prototyping of such systems. It also offers several mechanisms for local surface modifications under conditions compatible with conservation of protein functionality of enzymes and antibodies. The subsequent imaging of the immobilized activity provides direct information about local immobilized enzyme activity. The range of biotechnological applications can be expanded by labeling other biomolecules, such as monoclonal antibodies, with appropriate enzymes. Miniaturized electrochemical enzyme immunoassays that apply the sandwich format and SECM as the detection method are reviewed. They have been performed on microstructured supports after reagent spotting or on agglomerates of surface-modified magnetic microbeads. Finally, current challenges are listed with indications of ongoing research to overcome current limitations by means of instrumental improvements. Received: 19 December 2000 / Revised: 26 February 2001 / Accepted: 2 March 2001  相似文献   

7.
Patterning of glassy carbon surfaces grafted with a layer of nitrophenyl moieties was achieved by using the direct mode of scanning electrochemical microscopy (SECM) to locally reduce the nitro groups to hydroxylamine and amino functionalities. SECM and atomic force microscopy (AFM) revealed that potentiostatic pulses applied to the working electrode lead to local destruction of the glassy carbon surface, most likely caused by etchants generated at the positioned SECM tip used as the counter electrode. By applying galvanostatic pulses, and thus, limiting the current during structuring, corrosion of the carbon surface was substantially suppressed. After galvanostatic patterning, unambiguous proof of the formation of the anticipated amino moieties was possible by modulation of the pH value during the feedback mode of SECM imaging. This patterning strategy is suitable for the further bio‐modification of microstructured surfaces. Alkaline phosphatase, as a model enzyme, was locally bound to the modified areas, thus showing that the technique can be used for the development of protein microarrays.  相似文献   

8.
Two-dimensional micropatterns of microparticles were fabricated on glass substrates with negative dielectrophoretic force, and the patterned microparticles were covalently bound on the substrate via cross-linking agents. The line and grid patterns of microparticles were prepared using the repulsive force of negative dielectrophoresis (n-DEP). The template interdigitated microband array (IDA) electrodes (width and gap 50 mum) were incorporated into the dielectrophoretic patterning cell with a fluidic channel. The microstructures on the glass substrates with amino or sulfhydryl groups were immobilized with the cross-linking agents disuccinimidyl suberate (DSS) and m-maleimidobenzoyl-N-hydroxy-succinimide ester (MBS). Diaphorase (Dp), a flavoenzyme, was selectively attached on the patterned microparticles using the maleimide groups of MBS. The enzyme activity on the patterned particles was electrochemically characterized with a scanning electrochemical microscope (SECM) in the presence of NADH and ferrocenylmethanol as a redox mediator. The SECM images proved that Dp was selectively immobilized onto the surface of microparticles to maintain its catalytic activity.  相似文献   

9.
Xia Chu  Daxue Duan  Guoli Shen  Ruqin Yu 《Talanta》2007,71(5):2040-2047
A new amperometric biosensor for glucose was developed based on adsorption of glucose oxidase (GOx) at the gold and platinum nanoparticles-modified carbon nanotube (CNT) electrode. CNTs were covalently immobilized on gold electrode via carbodiimide chemistry by forming amide linkages between carboxylic acid groups on the CNTs and amine residues of cysteamine self-assembled monolayer (SAM). The fabricated GOx/Aunano/Ptnano/CNT electrode was covered with a thin layer of Nafion to avoid the loss of GOx in determination and to improve the anti-interferent ability. The immobilization of CNTs on the gold electrode was characterized by quartz crystal microbalance technique. The morphologies of the CNT/gold and Ptnano/CNT/gold electrodes have been investigated by scanning electron microscopy (SEM), and the electrochemical performance of the gold, CNT/gold, Ptnano/gold and Ptnano/CNT/gold electrodes has also been studied by amperometric method. In addition, effects of electrodeposition time of Pt nanoparticles, pH value, applied potential and electroactive interferents on the amperometric response of the sensor were discussed.

The enzyme electrode exhibited excellent electrocatalytic activity and rapid response for glucose in the absence of a mediator. The linear range was from 0.5 to 17.5 mM with correction coefficient of 0.996. The biosensor had good reproducibility and stability for the determination of glucose.  相似文献   


10.
We have studied the micropatterning and characterization of the organic monolayers using cyclic voltammetry (CV), scanning electrochemical microscopy (SECM), atom force microscopy, and AC impedance, and have determined the electrochemical parameters, i.e., the apparent reaction rate constant (K f) and the coverage of the electrode surface (θ). CV and SECM experiments demonstrated that the surface of the modified electrode represents an insulating substrate for ferricyanide. Using the high sensitivity of the electron transfer of ferricyanide to the modification of the gold surface with DNA, we selected this reaction as a probe to study the different modification stages at this modified electrode. SECM images obtained from bare, partially modified, and totally modified electrodes showed very good resolution with different topographies or null according to the extent of modification. Based on a comparison with the results of the experiments, a reasonable agreement can be obtained, which means a conjunction of these techniques.  相似文献   

11.
Scanning electrochemical microscopy (SECM) in feedback mode was employed to characterise the reactivity and microscopic peculiarities of bismuth and bismuth/lead alloys plated onto gold disk substrates in 0.1 mol L?1 NaOH solutions. Methyl viologen was used as redox mediator, while a platinum microelectrode was employed as the SECM tip. The metal films were electrodeposited ex situ from NaOH solutions containing either bismuth ions only or both bismuth and lead ions. Approach curves and SECM images indicated that the metal films were conductive and locally reactive with oxygen to provide Bi3+ and Pb2+ ions. The occurrence of the latter chemical reactions was verified by local anodic stripping voltammetry (ASV) at the substrate solution interface by using a mercury‐coated platinum SECM tip. The latter types of measurements allowed also verifying that lead was not uniformly distributed onto the bismuth film electrode substrate. These findings were confirmed by scanning electron microscopy images. The surface heterogeneity produced during the metal deposition process, however, did not affect the analytical performance of the bismuth coated gold electrode in anodic stripping voltammetry for the determination of lead in alkaline media, even in aerated aqueous solutions. Under the latter conditions, stripping peak currents proportional to lead concentration with a satisfactory reproducibility (within 5 % RSD) were obtained.  相似文献   

12.
We report the stability and enzymatic activity of Candida rugosa Lipase (E.C.3.1.1.3) immobilized on gamma-Fe2O3 magnetic nanoparticles. The immobilization strategies were either reacting the enzyme amine group with a nanoparticle surface acetyl, or amine groups. In the former, the enzyme was attached through a C=N bond, while in the latter it was connected using glutaraldehyde. AFM images show an average particle size of 20 +/- 10 nm after deconvolution. The enzymatic activity of the immobilized lipase was determined by following the ester cleavage of p-nitrophenol butyrate. The covalently immobilized enzyme was stabile and reactive over 30 days.  相似文献   

13.
A rapid, simple and reproducible two-step method for constructing cholesterol biosensors by covalently bonding cholesterol oxidase (ChOx) to a 3,3′-dithiodipropionic acid di(N-succinimidyl ester) (DTSP)-modified gold electrode is described. Exhaustive characterizations of both the immobilization process and the morphological properties of the resulting ChOx monolayer were performed via a quartz crystal microbalance (QCM) and atomic force microscopy (AFM) operated under liquid conditions, respectively. In addition, scanning electrochemical microscopy (SECM) measurements were performed in order to check that the immobilized enzyme retains its catalytic activity. The replacement of the natural electron acceptor (O2) in the enzymatic reaction with an artificial mediator, hydroxymethylferrocene (HMF), was also studied. Finally, cholesterol was amperometrically determined by measuring the hydrogen peroxide produced during the enzymatic reaction at +0.5 V. The optimized cholesterol biosensor exhibited a sensitivity of 54 nA mM−1 and a detection limit of 22 μM.  相似文献   

14.
Electrodeposition of colloidal gold nanoparticles onto a planar gold electrode was used to create a more favorable surface for the attachment of the enzyme acetylcholinesterase. Atomic force microscopy demonstrated that the gold nanoparticles roughened the surface consequently enhancing the interaction of the enzyme with the gold electrode. The enzyme-modified electrode sensor was utilized for the sensitive electrochemical detection of thiocholine at the gold surface after hydrolysis of acetylthiocholine by the immobilized enzyme. In the absence of the nanoparticle layer, the sensor response to acetylthiocholine was significantly reduced and the utility of the electrode was limited. The ability of the nanoparticle-based sensor to reliably measure concentrations of the organophosphate pesticide carbofuran at nM concentrations was demonstrated by monitoring the inhibition of the hydrolysis of acetylthiocholine. This relatively straightforward strategy is potentially valuable for the development of new devices for the sensitive detection of potentially dangerous and deadly neurotoxins.  相似文献   

15.
《Electroanalysis》2006,18(11):1131-1134
The direct electrochemistry of glucose oxidase (GOD) was revealed at a carbon nanotube (CNT)‐modified glassy carbon electrode, where the enzyme was immobilized with a chitosan film containing gold nanoparticles. The immobilized GOD displays a pair of redox peaks in pH 7.4 phosphate buffer solutions (PBS) with the formal potential of about ?455 mV (vs. Ag/AgCl) and shows a surface‐controlled electrode process. Bioactivity remains good, along with effective catalysis of the reduction of oxygen. In the presence of dissolved oxygen, the reduction peak current decreased gradually with the addition of glucose, which could be used for reagentless detection of glucose with a linear range from 0.04 to 1.0 mM. The proposed glucose biosensor exhibited high sensitivity, good stability and reproducibility, and was also insensitive to common interferences such as ascorbic and uric acid. The excellent performance of the reagentless biosensor is attributed to the effective enhancement of electron transfer between enzyme and electrode surface by CNTs, and the biocompatible environment that the chitosan film containing gold nanoparticles provides for immobilized GOD.  相似文献   

16.
Gao N  Wang X  Li L  Zhang X  Jin W 《The Analyst》2007,132(11):1139-1146
This paper uses scanning electrochemical microscopy (SECM) coupled with an intracellular standard addition method to quantify enzyme activity in single intact cells. In this work, peroxidase (PO) inside human neutrophils is chosen as the model system. Cells immobilized onto a silanized coverslip are perforated with digitonin to form micropores on the cell membrane. Hydroquinone (H(2)Q) and hydrogen peroxide (H(2)O(2)) as the enzyme substrates diffuse through the micropores into the cell interior. There, H(2)Q is converted into benzoquinone (BQ) by intracellular PO. BQ diffuses with a steady flux through the micropores from the cell interior onto the cell surface. The BQ near the cell surface is detected by the Au tip of SECM held at -0.3 V. When the tip is scanned laterally along the central line over the cell, a 2-D scan curve is obtained. Then, the intracellular standard addition method using ultramicroinjection with a submicrometer-sized micropipette tip is performed. After ultramicroinjection of a standard solution, another 2-D scan curve is recorded. The intercellular enzyme activity can be calculated from both peak current on two scan curves. This method to quantify PO activity in the cell environment has several obvious advantages: high sensitivity due to signal amplification via intracellular enzyme-catalyzed reaction and no sample dilution, no electrode fouling from adsorption of intracellular biological molecules, and no interference from electro-active compounds that can be directly oxidized at the SECM tip or from oxygen in the detected solution.  相似文献   

17.
免疫传感器以其高度特异性抗原抗体结合反应的特点 ,可直接、快速而灵敏地测定抗原或抗体分子而被广泛应用于临床医学以及环境污染物检测等领域 [1] .目前 ,检测抗原抗体结合的无标志方法主要有石英晶体微天平 [2 ] 、表面等离子共振 [3 ] 、界面电容 [4 ] 及原子力显微镜 [5]  相似文献   

18.
《Electroanalysis》2006,18(16):1572-1577
An amperometric tyrosinase biosensor was developed via a simple and effective immobilization method using the self‐assembled monolayers (SAMs) technique. The organic monolayer film was first formed by the spontaneous assembly of thiolor sulfur compound (1,6‐hexanedithiol, HDT) from solution onto gold electrode. When these thiol‐rich surfaces were exposed to Au colloid, the sulfurs form strong bonds to gold nanoparticles, anchoring the clusters to the electrode substrate. After the assembly of gold nanoparticles layer, a new nano‐Au surface was obtained. Thus, the tyrosinase could be immobilized onto the electrode. The tyrosinase retained its activity well in such an immobilization matrix. The various experimental variables for the enzyme electrode were optimized. The resulting biosensor can reach 95% of steady‐state current within 10 s, and the trend in the sensitivity of different phenolic compounds was as follows: catechol>phenol>p‐cresol. In addition, the apparent Michaelis–Menten constant (K and the stability of the enzyme electrode were estimated.  相似文献   

19.
基于分子间静电相互作用力,将锇-聚乙烯吡啶复合物(PVP-Os)与辣根过氧化物酶(HRP)交替沉积于固体基质表面,制得了包含生物成分的分子多层膜.膜层间的聚合物分子起到了粘接与导电的双重作用.用紫外-可见光谱法跟踪了石英基片上的组装过程,研究了多层膜电极对过氧化氢的电催化还原性能,并描述了多层膜电化学行为.  相似文献   

20.
Cytochrome c was electrostatically immobilized onto a COOH-terminated alkanethiol self-assembled monolayer (SAM) on a gold electrode at ionic strengths of less than 40 mM. Scanning electrochemical microscopy (SECM) was used to simultaneously measure the electron transfer (ET) kinetics of the bimolecular ET between a solution-based redox mediator and the immobilized protein and the tunneling ET between the protein and the underlying gold electrode. Approach curves were recorded with ferrocyanide as a mediator at different coverages of cytochrome c and at different substrate potentials, allowing the measurement of k(BI) = 2 x 10(8) mol(-1) cm3 s(-1) for the bimolecular ET and k degrees = 15 s(-1) for the tunneling ET. The kinetics of ET was also found to depend on the immobilization conditions of cytochrome c: covalent attachment gave slightly slower tunneling ET values, and a mixed CH3/COOH-terminated ML gave faster tunneling ET rates. This is consistent with previous studies and is believed to be related to the degree of mobility of cyt c in its binding configuration and its orientation with respect to the underlying electrode surface.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号