首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 656 毫秒
1.
Cao J  Chen J  Yi L  Li P  Qi LW 《Electrophoresis》2008,29(11):2310-2320
Oil-in-water (O/W) and water-in-oil (W/O) MEEKC were compared for their abilities to separate and detect eight phenolic acids and five diterpenoids in Radix et Rhizoma Salviae Miltiorrhizae (RRSM). The effects of oil type and concentration, organic modifier, SDS, and buffer concentration on separation were examined in order to optimize the two methods. Oil contents and organic modifier were found to markedly influence the separation selectivity for both O/W and W/O systems. SDS concentration rarely affected separation resolution for O/W MEEKC, and separation of eight phenolic acids and five diterpenoids could be improved by changing the buffer concentration for W/O MEEKC. A highly efficient O/W MEEKC separation method, where the 13 compounds were separated with baseline resolution, was achieved by using a microemulsion solution of pH 8.0 containing 0.6% cyclohexane, 3.0% SDS, 6.0% 1-butanol, and 3.0% ACN. The W/O MEEKC was unable to resolve all the components. In addition, the analytic time in O/W MEEKC was shorter than that in W/O MEEKC. Finally, the developed O/W MEEKC method was successfully applied to determine analytic compounds in RRSM samples.  相似文献   

2.
Huang HY  Lien WC  Huang IY 《Electrophoresis》2006,27(16):3202-3209
In this study, anion-selective exhaustive injection-sweeping (ASEI-sweeping) technique, which is a selective on-line sample concentration technique, was first proposed in microemulsion electrokinetic chromatography (MEEKC) for analyses of eight acidic phenolic compounds. In contrast to a capillary that is typically filled with nonmicellar background solution in conventional ASEI-sweeping MEKC method, in the proposed ASEI-sweeping MEEKC method, a capillary is filled with a low pH microemulsion solution (pH 2.0), and then with a short acid plug (pH 2.0, 1.9 cm) before field-amplified sample injection. This proposed design has two functions. First, the microemulsion solution that is present at the front of capillary column is able to avoid phase separation of microemulsion solution during MEEKC separation. Second, the presence of the short acid plug would effectively limit the partition behavior of acid analytes with the oil droplets in the microemulsion during field-amplified sample injection; otherwise, the stacking effect of acid analytes would be markedly reduced. This optimal ASEI-sweeping MEEKC method afforded about 96,000-fold to 238,000-fold increases in detection sensitivity in terms of peak areas without any separation efficiency loss when compared to normal MEEKC separation. Furthermore, trace levels (about 3 ng/g) of gallic acid and catechin in foods were also detected successfully by the proposed ASEI-sweeping MEEKC technique.  相似文献   

3.
Cao J  Qu H  Cheng Y 《Electrophoresis》2010,31(20):3492-3498
In this work, a new ionic liquid-in-water (IL/W) microemulsion without requiring toxic organic solvents was investigated as a pseudostationary phase (PSP) in CE. As observed during the IL/W microemulsion system, a fast and an efficient separation of eight phenolic acids was achieved using 1-butyl-3-methylimidazolivmhexa fluorophosphate (bmimPF(6)) as oil drops, Tween 20 as the surfactant, and borate as the BGE. The effects of oil phase, surfactant, buffer and pH on the separation were explored in detail to evaluate the novel PSP. In contrast, the detection efficiency of these same analytes was markedly decreased using oil-in-water (O/W) MEEKC. We have also validated the practicality of the IL/W microemulsion method by quantitative determination of acidic compounds in pharmaceutical injection. The results obtained indicated that an additional association between the IL cations and analytes tested seemed to play a prominent role in the separation mechanism exhibited by this novel PSP compared with the conventional O/W MEEKC.  相似文献   

4.
Huang HY  Hsieh SH 《Electrophoresis》2008,29(18):3905-3915
In this study, on-line sample concentration methods, which coupled field-amplified sample injection and sweeping technology with MEEKC, were used to detect and analyze eight common penicillin antibiotics (nafcillin, dicloxacillin, ampicillin, oxacillin, penicillin V, cloxacillin, penicillin G, and amoxicillin). During the optimization of field-amplified sample injection-sweeping MEEKC, the composition of sample matrix and the length of acidic plug were found to be the predominant influences for penicillin stacking. Both zwitterionic ampicillin and amoxicillin could only be stacked through cation-selective-exhaustive-injection sweeping, whereas the other six penicillin compounds were found to be concentrated by anion-selective-exhaustive-injection sweeping. Hence, in order to simultaneously concentrate the eight penicillins in a single-run sweeping step, a combination of successive anion- and cation-selective injections was used. When compared with previous CE-UV methods, the proposed on-line concentration MEEKC method provided better detection sensitivity and faster separation for these penicillins either in single ion-selective injection or in successive anion-/cation-selective injection where the LODs were in the range of 0.2-2.8 microg/L and 0.5-5.8 microg/L, respectively.  相似文献   

5.
Microemulsion EKC (MEEKC) was developed for quantitative analysis of curcuminoids, such as curcumin (C), demethoxycurcumin (D), and bis-demethoxycurcumin (B). MEEKC separation of curcuminoids was optimized, and a change in resolution was explained using a modified equation for resolution in MEEKC without electroosmosis. The suitable MEEKC conditions for separation of curcuminoids were obtained to be the microemulsion buffer containing 50 mM phosphate buffer at pH 2.5, 1.1% v/v n-octane as oil droplets, 180 mM SDS as surfactant, 890 mM 1-butanol as cosurfactant, and 25% v/v 2-propanol as organic cosolvent; applied voltage of -15 kV; and separation temperature 25 degrees C. Achieved baseline resolution of C:D and D:B was obtained with R(s) -2.4 and analysis time within 18 min. In addition, high accuracy and precision of the method were obtained. This MEEKC method was used for quantitative determination of individual curcuminoids in medicinal turmeric capsules and powdered turmeric used as coloring additive in food, with simple sample preparation such as solvent extraction, dilution, and filtration, and without cleaning up by SPE.  相似文献   

6.
In this study, an on-line concentration method which coupled cation-selective exhaustive injection (CSEI) sweeping technology with microemulsion electrokinetic chromatography (MEEKC) was used to detect and analyze several tobacco alkaloids (nornicotine, anabasine, anatabine, nicotine, myosmine and cotinine) that are commonly found in various tobacco products. First, the effects of microemulsion compositions (oil, cosurfactant and solution pH) were examined in order to optimize the alkaloid separations in conventional MEEKC. The pH value and the injection length of basic plug were found to be the predominant influences on the alkaloid stacking. This optimal CSEI sweeping MEEKC method provided approximately 180- to 540-fold increase in detection sensitivity in terms of peak height without any loss in separation efficiency when compared to normal MEEKC separation. Furthermore, this proposed CSEI sweeping MEEKC method was applied successfully for the detection of the minor alkaloids nornicotine, anabasine and anatabine in tobacco products.  相似文献   

7.
We describe the novel use of water-in-oil (W/O) microemulsions to achieve unique separations in microemulsion electrokinetic chromatography (MEEKC). The choice and concentration of the buffer type, surfactant and co-surfactant were all examined and optimized. Separations of a range of neutral and acidic analytes was shown to be markedly different to that obtained by (oil-in-water) O/W MEEKC. Neutral solutes are separated by virtue of their solubility (log P) values in O/W MEEKC with the more water-insoluble solutes migrating last. This separation process does not occur in W/O, as neutral solutes are not separated in order of log P.  相似文献   

8.
Hua Yang  Yao Ding  Ping Li 《Electrophoresis》2013,34(9-10):1273-1294
Microemulsion electrokinetic chromatography (MEEKC) is a CE separation technique, which utilizes buffered microemulsions as the separation media. In the past two decades, MEEKC has blossomed into a powerful separation technique for the analysis of a wide range of compounds. Pseudostationary phase composition is so critical to successful resolution in EKC, and several variables could be optimized including surfactant/co‐surfactant/oil type and concentration, buffer content, and pH value. Additionally, MEEKC coupled with online sample preconcentration approaches could significantly improve the detection sensitivity. This review comprehensively describes the development of MEEKC from the period 1991 to 2012. Areas covered include basic theory, microemulsion composition, improving resolution and enhancing sensitivity methods, detection techniques, and applications of MEEKC.  相似文献   

9.
Zhang Y  Li Q  Lu M  Zhang L  Chen G  Cai Z 《色谱》2011,29(8):791-797
建立了一种微乳液毛细管电动色谱(MEEKC)-场放大富集(FASI)分析尿液中多种麻醉剂(吗啡、可待因、纳洛酮、海洛因、蒂巴因、可卡因、哌替啶、芬太尼、美沙酮)的方法。考察了微乳液组成、分离电压等因素的影响,得到的最佳微乳液组成(质量分数)为0.6%十二烷基硫酸钠、1.2%正丁醇、0.6%乙酸乙酯和97.6% 10 mmol/L硼砂缓冲液(pH 9.5);分离电压为25 kV。在上述微乳体系中,9种化合物在15 min内得到了基线分离。采用场放大在线富集技术提高了分析灵敏度,检出限(S/N=3)低至0.3 μg/L。模拟尿样样品中9种麻醉剂的加标回收率介于79.4%~119.9%之间,日内相对标准偏差小于5.5%。将该方法应用于美沙酮大鼠体外代谢样品的测定,结果令人满意。  相似文献   

10.
肖佳  黄颖  王敏毅  陈国南 《色谱》2012,30(9):951-956
建立了微乳液毛细管电动色谱(MEEKC)模式下,采用常规样品堆积模式(normal stacking mode, NSM)和反向极性堆积模式(reversed electrode polarity stacking mode, REPSM)两种在线富集邻苯二甲酸酯类化合物(phthalate esters, PAEs)的简便、有效方法。与常规MEEKC方法相比,REPSM-MEEKC方法使4种PAEs的检测灵敏度提高了937.5~7143倍。考察了常规MEEKC的分离条件,分别对影响两种富集过程的一些因素进行了研究,同时对两种富集方法的重现性和检出限等进行了考察。NSM-MEEKC和REPSM-MEEKC对邻苯二甲酸酯类化合物的检出限(按信噪比(S/N)=3计)分别为0.021~0.33 mg/L和0.7~4 μg/L。其中,灵敏度更高的REPSM-MEEKC方法已成功应用于食品塑料袋中邻苯二甲酸酯类化合物的测定,加标回收率为89.1%~105.6%,结果令人满意。  相似文献   

11.
A microemulsion electrokinetic chromatographic (MEEKC) method was developed for the separation of six catechins, specific marker phytochemicals of Cistus species. The MEEKC method involved the use of sodium dodecyl sulfate (SDS) as surfactant, heptane as organic solvent and butan-1-ol as co-solvent. In order to have a better stability of the studied catechins, the separation was performed under acidic conditions (pH 2.5 phosphate buffer). The effects of SDS concentration and of the amount of organic solvent and co-solvent on the analyte resolution were evaluated. The optimized conditions (heptane 1.36% (w/v), SDS 2.31% (w/v), butan-1-ol 9.72% (w/v) and 50 mM sodium phosphate buffer (pH 2.5) 86.61% (w/v)) allowed a useful and reproducible separation of the studied analytes to be achieved. These conditions provided a different separation profile compared to that obtained under conventional micellar electrokinetic chromatography (MECK) using SDS. The method was validated and applied to the determination of catechin and gallocatechin in lyophilized extracts of Cistus incanus and Cistus monspeliensis.  相似文献   

12.
A microemulsion electrokinetic chromatography (MEEKC) method was developed to analyze and detect eight food colorants (tartrazine, fast green FCF, brilliant blue FCF, allura red AC, indigo carmine, sunset yellow FCF, new coccine, and carminic acid), which are commonly used as food additives in various food products. The effects of sodium dodecyl sulfate (SDS) surfactant, organic modifier, cosurfactant, and oil were examined in order to optimize the separation. The amount of organic modifier (acetonitrile) and SDS surfactant were determined as apparent influences on the separation resolution while the type of oil and cosurfactant rarely affected the separation selectivity of the eight colorants. A highly efficient MEEKC separation method, where the eight colorants were separated with baseline resolution within 14 min, was achieved by using a microemulsion solution of pH 2.0 containing 3.31% SDS, 0.81% octane, 6.61% 1-butanol, and 10% acetonitrile. This optimal MEEKC method has a higher separation efficiency and similar detection limit when compared to conventional capillary electrophoresis (CE) method. Furthermore, a sample pretreatment is rarely needed when this MEEKC technique is used to analyze colorants in food products, whereas a suitable sample pretreatment (for example solid-phase extraction) has to be employed prior to CE separation in order to eliminate matrix interferences resulting from the constituents of the food sample.  相似文献   

13.
Klampfl CW 《Electrophoresis》2003,24(10):1537-1543
The contribution of organic solvents to the mechanisms responsible for separation in microemulsion electrokinetic chromatography (MEEKC) is reviewed. Organic solvents are needed as constituents of microemulsions for a series of reasons. (i). A water-immiscible organic substance is used to form the actual oil phase of the microemulsion, (ii). a less hydrophobic solvent is commonly employed as a so-called co-surfactant, and (iii). in many cases an organic modifier is added to influence the solubility of the analytes in the aqueous phase of the microemulsion. All these organic solvents do not only participate in the separation in their actual function, but also interact with each other and the analytes. Variations in separation selectivities triggered by changes in the nature and/or concentration of these organic solvents present in microemulsions suitable for MEEKC are discussed in this work.  相似文献   

14.
Bitar Y  Holzgrabe U 《Electrophoresis》2007,28(15):2693-2700
CD-modified microemulsion EKC as a CE technique has been applied to the chiral separation of atropine, scopolamine, ipratropium and homatropine. Enantioseparations of these tropa alkaloids were optimized by using a standard oil-in-water (O/W) microemulsion and varying the nature and concentration of CD additives as well as of the organic modifier (methanol, 2-propanol or ACN) whilst keeping the applied voltage of 15 kV and capillary temperature of 30 degrees C constant. The standard (O/W) microemulsion BGE solution consisted of 0.8% w/w octane, 6.6% w/w 1-butanol, 2.0% w/w SDS and 90.6% w/w 10 mM sodium tetraborate buffer (pH 9.2). Enantioseparations with high resolution and short migration times of all tropa alkaloids were achieved by using heptakis(2,3-di-O-methyl-6-O-sulfo)-beta-CD and sulfated beta-CD in the microemulsion BGE and were superior to corresponding CD-modified CE methods.  相似文献   

15.
建立了微乳液毛细管电动色谱同时分析消炎利胆片中穿心莲内酯和脱水穿心莲内酯的方法。考察了缓冲溶液的浓度、pH值、十二烷基硫酸钠(SDS)以及助表面活性剂的含量对分离测定的影响。在由乙酸乙酯-SDS-正丁醇-30 mmol/L硼砂缓冲液(pH 9.5)(质量比为0.5∶0.6∶6.0∶92.9)组成的微乳液体系中,两种内酯在6 min内完成分离。该法简便、快速、选择性好,用于实际样品中穿心莲内酯和脱水穿心莲内酯的分析,获得了满意的结果。  相似文献   

16.
The migration behaviour of isoquinoline, quinoline, and methyl derivatives of quinoline in different capillary electrophoretic modes has been systematically investigated. Optimised separation conditions were established by varying the key parameters (solvent, pH, temperature, surfactant concentration, core phase) for aqueous and non‐aqueous capillary zone electrophoresis (NACE), micellar electrokinetic chromatography (MEKC) with anionic or non‐ionic micelles (SDS, Brij 35), and microemulsion electrokinetic chromatography (MEEKC) with charged or uncharged microemulsion droplets. A separation of all quinolines could be achieved by MEEKC with charged droplets, by MEKC or by formamide‐based NACE. Comparing the separations with respect to separation selectivity, substantial changes in migration order could be observed between the different techniques. Regarding separation efficiency, the number of theoretical plates and limits of detection (LOD) have been compared. The best LODs were achieved using SDS as surfactant in MEKC, followed by MEEKC.  相似文献   

17.
Chen Z  Lin Z  Zhang L  Cai Y  Zhang L 《The Analyst》2012,137(7):1723-1729
A novel method of microemulsion electrokinetic capillary chromatography (MEEKC) coupled with on-line large volume sample stacking was developed for the analysis of six plant hormones including indole-3-acetic acid, indole-3-butyric acid, indole-3-propionic acid, 1-naphthaleneacetic acid, abscisic acid and salicylic acid. Baseline separation of six plant hormones was achieved within 10 min by using the microemulsion background electrolyte containing a 97.2% (w/w) 10 mM borate buffer at pH 9.2, 1.0% (w/w) ethyl acetate as oil droplets, 0.6% (w/w) sodium dodecyl sulphate as surfactant and 1.2% (w/w) 1-butanol as cosurfactant. In addition, an on-line concentration method based on a large volume sample stacking technique and multiple wavelength detection was adopted for improving the detection sensitivity in order to determine trace level hormones in a real sample. The optimal method provided about 50-100 fold increase in detection sensitivity compared with a single MEEKC method, and the detection limits (S/N = 3) were between 0.005 and 0.02 μg mL(-1). The proposed method was simple, rapid and sensitive and could be applied to the determination of six plant hormones in spiked water samples, tobacco leaves and 1-naphthylacetic acid in leaf fertilizer. The recoveries ranged from 76.0% to 119.1%, and good reproducibilities were obtained with relative standard deviations (RSDs) less than 6.6%.  相似文献   

18.
A novel additive of multi‐walled carbon nanotubes (MWNTs) dispersed with cationic surfactants or mixed cationic/anionic surfactants was used for MEEKC separation of eight phenolic compounds, four glycosides, and one phenanthraquinone. In this context, several parameters affecting MEEKC separation were studied, including the dispersion agents of MWNTs, MWNTs content, oil type, SDS concentration, and the type and concentration of cosurfactant. Compared with conventional MEEKC, the addition of all types of MWNTs dispersions using single or mixed cationic surfactant solutions in running buffers was especially useful for improving the separation of solutes tested, as they influenced the partitioning between the oil droplets and aqueous phase due to the exceptional electrical properties and large surface areas of MWNTs. Use of cationic surfactant‐coated MWNTs (6.4 μg/mL) as the additive in a microemulsion buffer (0.5% octanol, 2.8% SDS, 5.8% isopropanol, and 5 mM borate buffer) yielded complete resolution of 13 analytes. The proposed method has been successfully applied for the detection and quantification of the studied compounds in a complex matrix sample (Compound Xueshuantong capsule).  相似文献   

19.
The separation of anionic, cationic and neutral drugs in microemulsion electrokinetic chromatography (MEEKC) was studied with a statistical experimental design. The concentration of sodium dodecyl sulfate (SDS, surfactant), 1-butanol (co-surfactant) and borate buffer and the factors Brij 35 (surfactant), 2-propanol (organic solvent) and cassette temperature were varied simultaneously, while the parameters pH (9.2), the concentration of octane (oil, 0.8% w/w), the voltage (10 kV) and the dimension of the fused-silica capillary, were kept constant. Eight different model substances were chosen with different hydrophobicities. Two of the analytes were positively charged, two were negatively charged, and the remaining four were neutral or close to neutral at the pH explored. The importance of each parameter on the separation window, the plate height and the retention factor for each of the analytes was studied by means of multiple linear regression (MLR) models. A new response was evaluated for anions, the quotient between the effective mobility in the microemulsion and the effective mobility in the corresponding buffer. Factors affecting selectivity changes were also explored, and it was found that SDS and 2-propanol had the largest effect on selectivity.  相似文献   

20.
The influences of the composition of microemulsion on the microstructure including dimensions and ζ potentials of microdroplets were measured in details. The average dynamic dimension of microdroplets was measured by dynamic laser light scattering, and ζ potential was determined to characterize average surface charge density of microdroplets. The experiment results showed that increase of the amount of surfactant resulted in decrease of microdroplet size but almost invariant ζ potential, which would enlarge migration time of the microdroplet in MEEKC. With increment of cosurfactant concentration, the microdroplet size had an increasing trend, whereas the ζ potential decreased. Thus, observed migration velocity of microdroplets increased, which made the separation window in MEEKC shortened. Neither dimension nor ζ potential of microdroplets changed by varying both the type and the amount of the oil phase. Adding organic solvent as modifier to microemulsion did not change the microdroplet size, but lowered ζ potential. The migration time of microdroplet still became larger, since EOF slowed down owing to organic solvent in capillary. So, besides increment of surfactant concentration, organic additive could also enlarge the separation window. Increase of cosurfactant concentration was beneficial for separation efficiency thanks to the looser structure of swollen microdroplet, and the peak sharpening might compensate for the resolution and peak capacity owing to a narrow separation window. Except the oil phase, tuning the composition of microemulsion would change the microstructure, eventually could be exploited to optimize the resolution and save analysis time in MEEKC.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号