1.
《Analytical letters》2012,45(3):513-525
ABSTRACT

A preconcentration method based on the use of an activated carbon column has been established for flame atomic absorption spectrometric determinations of gold, silver and palladium. The analytes were sorbed on the column as a complex of dithiophosphoric acid O, O-diethyl ester (DDTP). The sorbed analytes were eluted through the column with 2M NH3 in acetone. Quantitative recoveries (≥95 %) for gold, silver and palladium were obtained from acidic solutions. The developing method was successfully applied to the determination of trace amounts of gold, silver and palladium in some samples with satisfactory results (relative standard deviation < 7 %; relative error < 3 %).  相似文献   

2.
In this paper, 5-(2-hydroxy-5-nitrophenylazo)thiorhodanine (HNATR) was synthesized. A new method for the simultaneous determination of palladium, platinum, rhodium and gold ions as metal-HNATR chelates was developed using a rapid analysis column high performance liquid chromatography equipped with on-line solid phase extraction technique. The samples (Water, human urine, geological samples and soil) were digested by microwave acid-digestion. The palladium, platinum, rhodium and gold ions in the digested samples were pre-column derivatized with HNATR to form colored chelates. The Pd-HNATR, Pt-HNATR, Rh-HNATR and Au-HNATR chelates can be absorbed onto the front of the enrichment column when they were injected into the injector and sent to the enrichment column [Zorbax Stable Bound, 10 mm x 4.6 mm, 1.8 microm] with a buffer solution of 0.05 mol L(-1) phosphoric acid as mobile phase. After the enrichment had finished, by switching the six ports switching valve, the retained chelates were back-flushed by mobile phase and travelling towards the analytical column. These chelates separation on the analytical column [Zorbax Stable Bound, 10 mm x 4.6 mm, 1.8 microm] was satisfactory with 72% acetonitrile (containing 0.05 mol L(-1) of phosphoric acid and 0.1% of Triton X-100) as mobile phase. The palladium, platinum, rhodium and gold chelates were separated completely within 2.5 min. Compared to the routine chromatographic method, more then 80% of separation time was shortened. By on-line solid phase extraction system, a large volume of sample (10 mL) can be injected, and the sensitivity of the method was greatly improved. The detection limits (S/N=3, the sample injection volume is 10 mL) of palladium, platinum, rhodium and gold in the original samples reaches 1.4, 1.8, 2.0 and 1.2 ng L(-1), respectively. The relative standard deviations for five replicate samples were 2.4-3.6%. The standard recoveries were 88-95%. This method was applied to the determination of palladium, platinum, rhodium and gold in human urine, water and geological samples with good results.  相似文献   

3.
建立了火试金减杂-电感耦合等离子体原子发射光谱法(ICP-AES)测定高冰镍中金、银、铂、钯含量的分析方法。实验采用火试金富集、熔融、灰吹得到合粒,通过减杂法得到银含量,通过ICP-AES法测定得到金、铂、钯含量。金、银、铂、钯的加标回收率在99.53%-101.83%之间,相对标准偏差小于3%。此方法快速、简洁,准确度高、精密度好,能够满足高冰镍的测定需求。  相似文献   

4.
A preconcentration method of gold, palladium and copper based on the sorption of Au (III), Pd (II) and Cu (II) ions on a column packed with 3-(2-aminoethylamino)propyl bonded silica gel is described. The modified silica gel was synthesized and characterized by FT-IR and C, H, N elemental analysis. At column preconcentration, the effects of parameters such as pH, volume, flow rate, matrix constituents of solutions and type of eluent on preconcentration of gold, palladium and copper were studied. The recoveries of Au (III), Pd (II) and Cu (II) were 98.93±0.51, 98.81±0.36 and 99.21±0.42 % at 95 % confidence level, respectively. The detection limits (δ) of the elements were 0.032, 0.016 and 0.012 μg ml−1, respectively. The preconcentration method was applied for determination of gold and palladium in certified reference material SARM 7B and copper in river and synthetic seawater by FAAS. Gold, palladium and copper were determined with relative error lower than 10 %.  相似文献   

5.
Sudo T  Igarashi S 《Talanta》1996,43(2):233-237
A new homogeneous liquid-liquid extraction using a fluorocarbon ionic surfactant, Zonyl FSA (FSA), having a diethylthioether group as a spacer between the perfluoroalkyl group and carboxyl group has been developed. In this FSA method, the phase separation phenomena were observed at mild pH (below pH 6). Moreover, by using this extraction method as a preconcentration, a highly sensitive spectrofluorometric determination of chlorophyll a was established. The results for the standard chlorophyll a were as follows. The concentration factor (V(w)/V(o)) was 200 (water phase, V(w), 20 cm(3), water-immiscible phase, V(o), 100 mul), the distribution ratio, log D, was 4.85, the extraction percentage, E, was 99.7%, and the procedure time was approximately 30 min. The calibration curve was linear in the concentration range 2 x 10(-11)-3 x 10(-7) mol dm(-3) and the detection limit (S/N=3) was 1 x 10(-11) mol dm(-3). The relative standard deviation was 0.72% for 10(-8) mol dm(-3) (five determinations).  相似文献   

6.
A simple flame atomic absorption spectrometric (FAAS) procedure for the determination of lead, bismuth, gold, palladium and cadmium as impurities in Raney nickel and nickel oxide was developed using a preconcentration step on an Amberlite XAD-16 resin packed column. Lead, bismuth, gold, palladium and cadmium were quantitatively recovered and separated from a solution containing 1 M HCl and 0.3 M NaI by the column system. Effects of the various parameters such as reagent concentrations, sample volume, matrix effects, etc. have been investigated. Under optimized conditions, the relative standard deviation of the combined method of sample treatment, preconcentration and determination with FAAS (n = 7) is generally lower than 12%. The limit of detection (3s, n = 20) was between 10–270 ng/g. The results were used for separation and preconcentration of five trace elements from nickel matrices.  相似文献   

7.
《Analytical letters》2012,45(13):2805-2820
ABSTRACT

The preconcentration and separation of platinum and palladium from weakly acidic solution (pH=4) were done on microcolumn packed with Cellex-T resin. Selective platinum elution from the column was performed with 0.01 mol/l glycine solution at pH=12, while for palladium elution 1.2 mol/l thiourea (pH=0.5) or 4.0 mol/l potassium thiocyanate (pH=1) may be used. As the detection technique was used either FAAS or GFAAS, depending on the concentration of studied metals in the eluate.  相似文献   

8.
A flow injection system incorporating an alumina microcolumn has been coupled to inductively coupled plasma mass spectrometry (ICP-MS) for on-line preconcentration and determination of platinum (IV) in natural waters. Depending on the nature of the sample, a nominal preconcentration factor of up to 600 can be achieved by eluting with 50l of 2 mol/l NH4OH. The limit of detection after a 5 min preconcentration time was 4 ngl-1, with a relative standard deviation of 4% (100 ngl-1 working solution). The proposed method was assessed for the determination of platinum (IV) in natural waters, motor car exhaust and some common analytical reagents.  相似文献   

9.
A simple flame atomic absorption spectrometric (FAAS) procedure for the determination of lead, bismuth, gold, palladium and cadmium as impurities in Raney nickel and nickel oxide was developed using a preconcentration step on an Amberlite XAD-16 resin packed column. Lead, bismuth, gold, palladium and cadmium were quantitatively recovered and separated from a solution containing 1 M HCl and 0.3 M NaI by the column system. Effects of the various parameters such as reagent concentrations, sample volume, matrix effects, etc. have been investigated. Under optimized conditions, the relative standard deviation of the combined method of sample treatment, preconcentration and determination with FAAS (n = 7) is generally lower than 12%. The limit of detection (3s, n = 20) was between 10–270 ng/g. The results were used for separation and preconcentration of five trace elements from nickel matrices. Received: 8 February 2000 / Revised: 31 March 2000 / Accepted: 7 April 2000  相似文献   

10.
Oleschuk RD  Chow A 《Talanta》1998,45(6):1235-1245
Platinum and palladium are known to form complexes with the thiocyanate ion in solution. The isolation and separation of both platinum and palladium as thiocyanate complexes is demonstrated by passing them through an organic-impregnated filter (OIF) prepared with polyTHF. Simultaneous extraction is performed by converting both metals into the extractable form. Sequential extraction is achieved by exploiting the difference in the rates of formation for the extractable complexes of the two metals. The extraction of both metals is rapid with quantitative recoveries of platinum with flow rates as high as 600 ml min−1 in small samples, while recoveries from larger volume samples were considerably lower. Once extracted, the metals can be removed from the OIF by conversion to a non-extractable form with a high pH eluting solution. The rapid separation, isolation and preconcentration of both platinum and palladium from aqueous samples is demonstrated.  相似文献   

11.
Kanický V  Otruba V  Mermet JM 《Talanta》1999,48(4):859-866
The limits of detection, precision and matrix effects in the inductively coupled plasma spectrometry of platinum group metals (PGMs) and gold were measured and evaluated for four ICP-AES and one ICP-MS instrument. The sample matrix was a cationic surfactant used for the PGMs and gold preconcentration on a modified silica gel (C18). A sorption of ion associates of PGMs and gold chlorocomplexes with the cation of onium salt N(1-carbaethoxypentadecyl)-trimethyl ammonium bromide was considered. The calibration curves, limits of detection and matrix effects were evaluated in the presence of 0.003 mol dm(-3) of onium salt (1.3 mg cm(-3)) and 0.1 mol dm(-3) HCl. The values of limits of detection (3 sigma(bl)) of PGMs for all axial ICP instruments were mostly below 10 ng cm(-3). Lateral observation on dual view ICP instrument yielded only 3 times higher detection limits in comparison to the axial mode of the same spectrometer and the detection limits for ICP-MS instrument were on the levels of units or tens of pg cm(-3). These limits of detection did not significantly differ from values obtained with pure solutions. Matrix effects in the presence of onium salt did not exceed 12% depression in the analytical signals. Besides the coefficients of correlation, the uncertainties on centroids of concentrations were calculated for calibration graphs obtained by linear regression.  相似文献   

12.
Enzweiler J  Potts PJ 《Talanta》1995,42(10):1411-1418
A series of experiments was undertaken to measure the recovery efficiency of platinum, palladium and gold from silicate rocks using a sodium peroxide fusion followed by anion exchange separation of the analytes as chloro complexes. Results obtained by graphite furnace atomic absorption spectrometric analysis of standard solutions prepared in dilute HCl or HCl-acidified sodium peroxide solution showed that recoveries were near quantitative. However, when standard solutions were added to an alkaline sodium peroxide solution, which was then acidified, low results were obtained for platinum and gold (46% and 76% respectively). Low and variable results were also obtained when standard solutions were added to a peridotite sample that had been dissolved by the state procedure, and in the analysis of the South African Bureau of Standards certified reference material, SARM 7. Various experiments were undertaken to investigate these low recoveries, but the reason proposed here is the formation of hydroxychloro compounds in alkaline solution which are not, on acidification with HCl, converted quantitatively to the chloro complex necessary for quantitative anion exchange separation. It is concluded that a sodium peroxide fusion followed by an anion-exchange separation does not appear to form the basis of a successful technique for the determination of platinum, palladium and gold in silicate rocks.  相似文献   

13.
A flow injection system incorporating an alumina microcolumn has been coupled to inductively coupled plasma mass spectrometry (ICP-MS) for on-line preconcentration and determination of platinum (IV) in natural waters. Depending on the nature of the sample, a nominal preconcentration factor of up to 600 can be achieved by eluting with 50microl of 2 mol/l NH(4)OH. The limit of detection after a 5 min preconcentration time was 4 ngl(-1), with a relative standard deviation of 4% (100 ngl(-1) working solution). The proposed method was assessed for the determination of platinum (IV) in natural waters, motor car exhaust and some common analytical reagents.  相似文献   

14.
The adsorption properties of dioxouranium (II)-Phathalate complexes onto hanging mercury drop electrode are exploited in developing a highly sensitive and selective stripping voltammetric procedure for the determination of uranium (VI). The reduction current of adsorbed complex ions of U(VI) was measured by both linear sweep (LSCSV) and differential pulse cathodic stripping voltammetry (DPCSV), preceded by a period of preconcentration onto the electrode surface. As low as 2x10(-9) mol dm(-3) (0.5 mug/l) and 2x10(-8) mol dm(-3) (4.8 mug/l) with accumulation time 240 and 120 s using DPCSV and LSCSV, respectively, have been determined successfully. The relative standard deviation of 2.2% at the 5 ppm level was obtained. The interferences of some metal ions and anions were studied. The application of this method was tested in the determination of uranium in superphosphate fertilizer.  相似文献   

15.
The solid-phase extraction (SPE) method for the preconcentration of trace amounts of cadmium using synthetic zeolite A-4 and its determination by graphite furnace atomic absorption spectrometry (GFAAS) was investigated. The preconcentration conditions, such as the optimum pH range of the sample solution for the adsorption of cadmium and the kind of acid solution for dissolving the cadmium-adsorbed synthetic zeolite A-4, as well as the measurement conditions for the determination of cadmium by GFAAS, e.g., the ashing and atomizing temperature, were investigated. Quantitative recovery of cadmium onto zeolite A-4 from the sample solution over the pH range 2.0 - 9.0 was achieved by the batch method. After the solid-phase (cadmium-adsorbed zeolite A-4) was separated from the sample solution by a membrane filter, it was dissolved in 2.0 cm(3) of 2.0 mol dm(-3) nitric acid. An aliquot of the resulting solution was injected into the graphite furnace. In GFAAS measurements an alternate gas (Ar, 90%; O(2), 10%) was used as a sheath gas, and the ashing temperature and atomizing temperature were 400 degrees C and 1600 degrees C, respectively. The detection limit (3 sigma) for cadmium was 0.002 microg dm(-3). The relative standard deviation at 0.010 microg dm(-3) was 3.5 - 4.5% (n = 5). The proposed method has been successfully applied to the analysis of trace cadmium in environmental water samples.  相似文献   

16.
Controlled-pore silica glass modified with N-propylsalicylaldimine (SCPSG) has been investigated as a surface-active matrix for the separation of some metal ions. The porous silica glass base was confirmed to have better stability towards hydrolysis in aqueous solution buffered at pH=9 in comparison to silica gel, which showed twice the surface area of controlled-pore silica glass. The different analytical parameters affecting the batch mode separation and preconcentration of trace Al(II), Ag(I) and Hg(II) in environmental samples using SCPSG, prior to their determination using inductively coupled plasma mass spectrometry (ICP-MS), were studied. The optimum conditions are pH 9.0 +/- 0.1, time of stirring 30 min and the eluent concentration 0.5 mol dm(-3) HNO3. The ion-exchange capacity of SCPSG with respect to Al(III), Ag(I) and Hg(II) was 0.27, 0.18 and 0.23 mmol g(-1), respectively. The recovery values for the metal ions were 96.8 +/- 0.86, 98.1 +/- 0.60 and 96.2 +/- 1.06%, and the analytical detection limits were 26.1, 1.49 and 0.44 pg cm(-3), respectively, for a preconcentration factor of 100. The method has been applied to the determination of the investigated metal ions in natural water samples as well as certified and reported samples and the results were found to be accurate.  相似文献   

17.
Solvent extraction with 0.05 mol L(-1) dicyclohexano-18-crown-6 (DC18C6) in 1,2-dichloroethane, coupled with flame atomic absorption spectrometry (AAS), has been investigated as a new method for separation of trace amounts of silver(I) from 0.05 mol L(-1) potassium thiocyanate in 1.0 mol L(-1) hydrochloric acid media and quantification of the amount of silver present. The method is based on the formation of an extractable ion-association product, [DC18C6.K](+)[Ag(SCN)(2)](-), with a metal-to-crown ether ratio of 1:1 (as derived from slope analysis data). Stripping of the extracted silver(I) in the 1,2-dichloroethane phase was achieved within 5 min by use of 3.0 mol L(-1) potassium thiocyanate. Reducing the concentration of acid in the sample solution to 0.1 mol L(-1) improved the preconcentration factor severalfold. Excellent tolerance of the proposed method to the presence of foreign ions in solution with silver(I) was demonstrated. A detection limit of 13 ng mL(-1) was derived from the mean value of the blank plus three times its standard deviation. The method was used to determine traces of silver(I) after separation from gold(III), platinum(IV), and palladium(II) matrices on the basis of extractability differences with 18-membered crown ethers under specified conditions. The efficiency of the adopted ion-association mechanism for silver(I) extraction was apparent from the average recovery of 96% for spiked standards by use of the back-washing technique. The proposed extraction procedure was applied to the determination of traces of silver(I) in a selection of chemical reagents.  相似文献   

18.
A water-insoluble chelating material, p-dimethylaminobenzylidenerhodanine on silica gel (DMABR—SG) is described for preconcentration of trace amounts of silver(I), gold(III) and palladium(II) from water samples. Radioactive tracers (110mAg and 195Au) were used to study the behavior of silver and gold; palladium was monitored spectrophotometrically as its 1-(2-pyridylazo)naphthol complex in chloroform. In batch experiments, silver was quantitatively retained on the DMABR—SG at acidities ranging from 1.7 M to pH 5, and gold from 3 M to pH 5; equilibrium was achieved within 1 min for both elements. From sea water, silver ion was completely retained at pH 1.0–6.5 and gold ion at pH 1.0–3.5. In the case of palladium, shaking for about 20 min was required for quantitative retention at pH 1.0–5.0 for aqueous solution and at pH 1.0–7.0 for sea water. The chelating capacity of the DMABR—SG was 23 μmol Ag, 11 μmol Au and 11 μmol Pd per g. Quantitative recovery of silver and gold on DMABR—SG columns from sea water was achieved at higher flow rates (1–2 l h-1 and 2–3 l h-1, respectively) than with other chelating resins, e.g., Chelex 100, palladium required slower flow rate (150 ml h-1). Silver retained on the DMABR—SG column was completely eluted with 20 ml of 2.5% sodium thiosulfate solution but palladium remained on the column. Silver, gold and palladium were quantitatively eluted with 20 ml of 0.1% thiourea in 0.1 M hydrochloric acid.  相似文献   

19.
《Analytical letters》2012,45(1):93-109
ABSTRACT

A second derivative spectrophotometric method has been developed for the determination of palladium and platinum in mixtures. The method is based on the formation of the platinum and palladium complexes with 3-(2-thiazolylazo)-2, 6-diaminopyridine, (2, 6-TADAP), in the presence of 1.7 M perchloric acid solution, upon heating at 90° C for 30 min and on the subsequent direct derivative spectrophotometric measurement. The zero-crossing approach and the graphic method were used for determination of platinum and palladium, respectively. Each analyte was determinated in the presence of one another in the ranges 8.9×10-7 -3.1×10-5 M for platinum and 4.6×10-7 - 6.8×10-5 M, for palladium. The detection limits achieved (3a) were found to be 2.7×10-7 M of platinum and 1.4×10-7 M of palladium. The relative standard deviations were in all instances less than 1.0%. In this work is included a study of effect of interferents and the application of the proposed method in synthetic mixtures.  相似文献   

20.
Theophylline derivatives with some kinds of alkyl chains were synthesized and used in extraction experiments involving metal ions. Theophylline derivatives have exhibited a high selectivity for palladium over other precious metals and base metals. The extraction of palladium from acidic chloride media has been investigated using theophylline derivatives (= RN) as extractants. Palladium(II) was found to be extracted with 7-octyltheophylline according to the following reaction: PdCl2 + 2RN <==> PdCl2(RN)2. The extraction equilibrium constant was determined to be K = 2.67 x 10(8) ( moldm(-3))(-2). In addition, the stripping of palladium was performed to an extent of 100% by a single batchwise treatment with a 1.0 mol dm(-3) ammonia solution. The stoichiometric relation in the extraction of palladium was supported by an analysis using mass spectrometry.  相似文献   