首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A 19F MR chemical shift imaging (CSI) technique is presented which enables selective imaging of the antineoplastic drug 5-fluorouracil (5-FU) and its major catabolite α-fluoro-β-alanine (FBAL). The CSI sequence employs a chemical shift selective (CHESS) saturation pulse to suppress either the 5-FU or the FBAL resonance before the other component of the two-line 19F MR spectrum is measured. Because the transmitter frequency can always be set to the Larmor frequency of the 19F resonance to be imaged, this approach yields 5-FU and FBAL MR images free of chemical shift artifacts in read-out and slice-selection direction. In phantom experiments, selective 5-FU and FBAL images with a spatial resolution of 15 × 15 × 20 mm3 (4.5 ml) were obtained in 30 min from a model solution, whose drug and catabolite concentrations were similar to those estimated in the liver of tumor patients undergoing IV chemotherapy with 5-FU. The drug-specific MR imaging technique developed is, therefore, well-suited for the direct and noninvasive monitoring of the up-take and trapping of 5-FU in liver tumors in vivo.  相似文献   

2.

Purpose

The regional uptake of glucose in rat brain in vivo was measured at high resolution using spin-lock magnetic resonance imaging after infusion of the glucose analogue 2-deoxy-d-glucose (2DG). Previous studies of glucose metabolism have used 13C-labeled 2DG and NMR spectroscopy, 18F-labeled fluorodeoxyglucose (FDG) and PET, or chemical exchange saturation transfer (CEST) MRI, all of which have practical limitations. Our goal was to explore the ability of spin-lock sequences to detect specific chemically-exchanging species in vivo and to compare the effects of 2DG in brain tissue on CEST images.

Methods

Numerical simulations of R1p and CEST contrasts for a variety of sample parameters were performed to evaluate the potential specificity of each method for detecting the exchange contributions of 2DG. Experimental measurements were made in tissue phantoms and in rat brain in vivo which demonstrated the ability of spin-lock sequences for detecting 2DG.

Results

R1p contrast acquired with appropriate spin-lock sequences can isolate the contribution of exchanging protons in 2DG in vivo and appears to have better sensitivity and more specificity to 2DG–water exchange effects than CEST.

Conclusion

Spin-lock imaging provides a novel approach to the detection and measurement of glucose uptake in brain in vivo.  相似文献   

3.
Diffusion-weighted whole-body imaging with background body signal suppression (DWIBS) is a relatively new diffusion-based pulse sequence that produces positron emission tomography (PET) with 2-[fluorine-18]-fluoro-2-deoxy-D-glucose (18F-FDG)-like images. We tested the feasibility of DWIBS in detecting peritoneal ovarian cancer in a syngeneic mouse model. Female C57BL/6 mice were injected intraperitoneally with ID8 murine ovarian carcinoma cells. After 11 weeks, the abdomen was imaged by DWIBS. A respiratory gating diffusion-weighted spin-echo echo-planar imaging in abdomen was used (imaging parameters of field of view of 47×47 mm2, matrix size of 64×64 zero-filled to 256×256 and b-value of 1500 s/mm2). We also performed FDG microPET as the reference standard. For comparison of the correlating surface areas of tumor foci on both DWIBS and FDG microPET imaging, two-dimensional region-of-interest (ROI) analysis was performed, and correlation between the two modalities was determined. Mice were also subjected to macroscopic examination for tumor location and pathology after imaging. DWIBS in all mice depicted the tumors as abnormal high signal intensity. The results show that the ROI analysis of correlating lesions reveals relatively high correlation (r²=0.7296) and significant difference (P = .021) between DWIBS and FDG microPET. These results demonstrate that DWIBS has the potential for detecting peritoneal dissemination of ovarian cancer. Nonetheless, due to low ratios of image signal-to-noise and motion artifacts, DWIBS can be limited for lesions near the liver.  相似文献   

4.

Objectives

As a unique tool to assess metabolic fluxes noninvasively, 13C magnetic resonance spectroscopy (MRS) could help to characterize and understand malignancy in human tumors. However, its low sensitivity has hampered applications in patients. The aim of this study was to demonstrate that with sensitivity-optimized localized 13C MRS and intravenous infusion of [1-13C]glucose under euglycemia, it is possible to assess the dynamic conversion of glucose into its metabolic products in vivo in human glioma tissue.

Materials and Methods

Measurements were done at 3 T with a broadband single RF channel and a quadrature 13C surface coil inserted in a 1H volume coil. A 1H/13C polarization transfer sequence was applied, modified for localized acquisition, alternatively in two (50 ml) voxels, one encompassing the tumor and the other normal brain tissue.

Results

After about 20 min of [1-13C]glucose infusion, a [3-13C]lactate signal appeared among several resonances of metabolic products of glucose in MR spectra of the tumor voxel. The resonance of [3-13C]lactate was absent in MR spectra from contralateral tissue. In addition, the intensity of [1-13C]glucose signals in the tumor area was about 50% higher than that in normal tissue, likely reflecting more glucose in extracellular space due to a defective blood–brain barrier. The signal intensity for metabolites produced in or via the tricarboxylic acid (TCA) cycle was lower in the tumor than in the contralateral area, albeit that the ratios of isotopomer signals were comparable.

Conclusion

With an improved 13C MRS approach, the uptake of glucose and its conversion into metabolites such as lactate can be monitored noninvasively in vivo in human brain tumors. This opens the way to assessing metabolic activity in human tumor tissue.  相似文献   

5.

Background

The neurological complications of HIV infection remain poorly understood. Clinically, in vivo 1H magnetic resonance spectroscopy (MRS) demonstrates brain injury caused by HIV infection even when the MRI is normal. Our goal was to undertsand the dynamics of cerebral injury by performing a longitudinal in vivo 1H MRS study of the SIV/macaque model of neuroAIDS.

Results

Eight rhesus macaques were infected with SIVmac251 and serially imaged with MRI and 1H MRS to terminal AIDS or the endpoint of 2 years. During acute infection, there were stereotypical brain MRS changes, dominated by a significant elevation of the Cho/Cr ratio in the frontal cortex. Subsequently, brain metabolic patterns diverged between animals. There was an elevation of basal ganglia Cho/Cr four weeks post-inoculation in 2 animals that developed SIV encephalitis (p = 0.022). Metabolite ratios averaged across all 8 animals were not significantly different from baseline at any time point after 2 weeks post inoculation. However, linear regression analysis on all 8 animals revealed a positive correlation between a change in frontal lobe Cho/Cr and plasma viral load (P < 0.001, R = 0.80), and a negative correlation between NAA/Cr in the basal ganglia and the plasma viral load (P < 0.02, R = -0.73). No MRI abnormalities were detected at any time.

Conclusions

After infection with SIV, macaque brain metabolism changes in a complex manner that is dependent on brain region, host factors and viral load. An elevation of basal ganglia Cho/Cr 4 weeks after SIV infection may be marker of a propensity to develop SIV encephalitis. Elevations of Cho/Cr, often observed in CNS inflammation, were associated with increased plasma viral load during acute and chronic infection. Evidence of neuronal injury in the basal ganglia was associated with increased plasma viral load in the chronic stage of infection. These observations support the use of drugs capable of controlling the viral replication and trafficking of virus into the CNS, and may help explain the reduction in incidence of HIV-associated dementia in the era of HAART despite the inability of most of those drugs to effectively enter the CNS.  相似文献   

6.
Tumor blood volume (TBV) is an important factor in the metabolism of a tumor and in its response to therapy. Until recently, the only methods to determine TBV were highly invasive and many involved radioisotopes. In this study, a perfluorocarbon (PFC) emulsion, Oxypherol, was monitored by 19F magnetic resonance spectroscopy (MRS). TBVs, as determined by 19F MRS of in situ and excised radiation-induced fibrosarcoma (RIF-1) tumors (n = 9), were strongly correlated with the TBV measured by a radioisotope labeled albumin method (slopes of 1.1 and 0.8 with R = 0.86 and 0.91, respectively, by linear regression). In general, the TBV as calculated from the in situ MRS measurements (n = 24) decreased from 28 to 5 ml/100 g tumor mass for tumors ranging in mass from 0.15 to 2 g. However, there was an indication of an initial increase of TBV in tumors smaller than 0.5 g.  相似文献   

7.
Relaxation parameter estimation and brain activation detection are two main areas of study in magnetic resonance imaging (MRI) and functional magnetic resonance imaging (fMRI). Relaxation parameters can be used to distinguish voxels containing different types of tissue whereas activation determines voxels that are associated with neuronal activity. In fMRI, the standard practice has been to discard the first scans to avoid magnetic saturation effects. However, these first images have important information on the MR relaxivities for the type of tissue contained in voxels, which could provide pathological tissue discrimination. It is also well-known that the voxels located in gray matter (GM) contain neurons that are to be active while the subject is performing a task. As such, GM MR relaxivities can be incorporated into a statistical model in order to better detect brain activation. Moreover, although the MR magnetization physically depends on tissue and imaging parameters in a nonlinear fashion, a linear model is what is conventionally used in fMRI activation studies. In this study, we develop a statistical fMRI model for Differential T2? ConTrast Incorporating T1 and T2? of GM, so-called DeTeCT-ING Model, that considers the physical magnetization equation to model MR magnetization; uses complex-valued time courses to estimate T1 and T2? for each voxel; then incorporates gray matter MR relaxivities into the statistical model in order to better detect brain activation, all from a single pulse sequence by utilizing the first scans.  相似文献   

8.
[1-13C] pyruvate pre-polarized via DNP has been used in animal models to probe changes in metabolic enzyme activities in vivo. To more accurately assess the metabolic state and its change from disease progression or therapy in a specific region or tissue in vivo, it may be desirable to separate the downstream 13C metabolite signals resulting from the metabolic activity within the tissue of interest and those brought into the tissue by perfusion. In this study, a spectral-spatial saturation pulse that selectively saturates the signal from the metabolic products [1-13C] lactate and [1-13C] alanine was designed and implemented as outer volume suppression for localized MRSI acquisition. Preliminary in vivo results showed that the suppression pulse did not prevent the pre-polarized pyruvate from being delivered throughout the animal while it saturated the metabolites within the targeted saturation region.  相似文献   

9.
Electron paramagnetic resonance (EPR), optical absorption and emission spectra of Cr3+ ions doped in (30−x) (NaPO3)6+30PbO+40B2O3+xCr2O3 (x=0.5, 2.0, 3.0, 4.0 and 5.0 mol%) glasses have been studied. The EPR spectra exhibit resonance signals with effective g values at g≈4.55 and g≈1.97. The EPR spectra of x=3.0 mol% of Cr2O3 in sodium-lead borophosphate glass sample were studied at various temperatures (295-123 K). The intensity of the resonance signals increases with decrease in temperature. The optical absorption spectrum exhibits four bands characteristic of Cr3+ ions in octahedral symmetry. From the analysis of the bands, the crystal-field parameter Dq and the Racah interelectronic repulsion parameters B and C have been evaluated. The emission spectrum exhibit one broad band characteristic of Cr3+ ions in octahedral symmetry. This band has been assigned to the transition 4T2g (F)→4A2g (F). Correlating EPR and optical data, the molecular bonding coefficient (α) has been evaluated.  相似文献   

10.
31P MRS resonance ratios of tumors depend on the T1s of the phosphorus compounds. The objective of the 31P MRS study reported here was to investigate whether the phosphorus T1s of melanomas are influenced by the presence of melanin. One amelanotic (COX-t) and one melanotic (ROX-t) human melanoma xenograft line were studied at two different tumor volumes: 200 and 1000 mm3. 31P MRS was performed in nonanaesthetized mice at 4.7 T. The T1s were measured by using the superfast inversion recovery technique. Fraction of necrotic tissue in the tumors was determined by histological examination. The ROX-t tumors showed shorter T1s than the COX-t tumors at a volume of 200 mm3, where the fraction of necrotic tissue in the tumors was insignificant. The difference was similar in magnitude for all resonances. The T1s were not significantly different for COX-t and ROX-t at a volume of 1000 mm3, where the tumors of both lines had developed significant necrosis. The phosphorus T1s of melanomas without necrosis can be shortened significantly by the presence of melanin. The magnitude of the T1 shortening is similar for all major compounds. 31P MRS resonance ratios of melanomas are not altered significantly by correcting for effects of partial saturation.  相似文献   

11.
In vivo 31P MRS provides a unique and important imaging tool for studying high-energy phosphate metabolism and bioenergetics noninvasively. However, compared to 1H MRS, 31P MRS with a relatively low gyromagnetic ratio (γ) has a lower and limited sensitivity even at ultrahigh field. The proof of concept has been recently demonstrated that the use of high dielectric constant (HDC) materials between RF coil and object sample could increase MRI signal and reduce required RF transmission power for reaching the same RF pulse flip angle in the region of interest. For low-γ MRS applications operated at relatively lower frequency, however, it demands the dielectric materials with a much higher permittivity for achieving optimal performance. We conducted a 31P MRS imaging study using ultra-HDC (uHDC; with a relative permittivity of ~ 1200) material blocks incorporated with an RF volume coil at ultrahigh field of 7.0 T. The experimental results from phantom and human calf muscle demonstrate that the uHDC technique significantly enhanced RF magnetic transmit field (B1+) and reception field (B1) and the gain could reach up to two folds in the tissue near the uHDC blocks. The overall results indicate that the incorporation of the uHDC materials having an appropriate permittivity value with a RF coil can significantly increase detection sensitivity and reduces RF transmission power for X-nuclei MRS applications at ultrahigh field. The uHDC technology could provide an efficient, cost-effective engineering solution for achieving high detection sensitivity and concurrently minimizing tissue heating concern for human MRS and MRI applications.  相似文献   

12.
In this work the feasibility of measuring neuronal-glial metabolism in rat brain in vivo using co-infusion of [1,6-13C2]glucose and [1,2-13C2]acetate was investigated. Time courses of 13C spectra were measured in vivo while infusing both 13C-labeled substrates simultaneously. Individual 13C isotopomers (singlets and multiplets observed in 13C spectra) were quantified automatically using LCModel. The distinct 13C spectral pattern observed in glutamate and glutamine directly reflected the fact that glucose was metabolized primarily in the neuronal compartment and acetate in the glial compartment. Time courses of concentration of singly and multiply-labeled isotopomers of glutamate and glutamine were obtained with a temporal resolution of 11 min. Although dynamic metabolic modeling of these 13C isotopomer data will require further work and is not reported here, we expect that these new data will allow more precise determination of metabolic rates as is currently possible when using either glucose or acetate as the sole 13C-labeled substrate.  相似文献   

13.
Aberrant expression of ferritin, a major iron-binding protein, has shown to be involved in neurodegenerative diseases. In this study, we generated transgenic (Tg) mice of human ferritin heavy chain (FTH) gene and investigated the effects of ferritin overexpression in FTH-Tg brain by 1H-MRI and 1H-MRS. The mice displayed no apparent neurological symptoms, and no specific morphological and T2 alterations were found in the brain by MRI, and not even by histological studies. 1H-MRS, however, revealed that some metabolic markers were significantly altered in FTH-Tg brains compared to wild-type control brains, such as decreases in myo-inositol and glutamine, and an increase in lactate. Our present studies suggested that despite the absence of neurological, morphological, T2, and histological signatures, brain metabolisms were significantly affected in FTH-Tg mice. This study also highlights the usefulness of 1H-MRS in the analysis of transgenic mouse models.  相似文献   

14.
Parkinson's disease (PD) is a neurodegenerative disorder characterized by the progressive loss of the dopaminergic neurons in the substantia nigra pars compacta, which projects to the striatum. We induced a selective loss of nigrostriatal dopamine neurons, by infusing the mitochondrial complex 1 inhibitor 1-methyl 4-phenyl 1,2,3,6-tetrahydropyridine (MPTP) into adult beagle dogs (N=5). Single voxel 1H water suppressed magnetic resonance spectroscopy (1H-MRS) at 3 T was used to assess the metabolic changes in the striatum of canine before and after MPTP intoxication. The metabolite spectra obtained from the striatum (voxel size: 2 cm3) showed a lower N-acetyl aspartate to total creatine (creatine+phosphocreatine) ratio after MPTP intoxication. There were no significant differences in other metabolite ratios such as glutamate+glutamine, choline-containing compounds (glycerophosphocholine+phophorylcholine and myo-inositol). Our findings indicated that 1H-MRS is a sensitive, noninvasive measure of neural toxicity and biochemical alterations of the striatum in a canine model of PD, and further studies are needed to confirm brain metabolic changes in association with progression of MPTP-intoxication.  相似文献   

15.
The maintenance of a gradient of potassium and sodium ions across the cell membranes is essential for the physiological function of the mammal organism. The measurement of the spatial distribution of pathologically changing ion concentrations of 23Na and 39K with magnetic resonance imaging offers a promising approach in clinical diagnostics to measure tissue viability. Existing studies were focused mainly on 23Na imaging as well as spectroscopy with only one post-mortem study for 39K imaging. In this paper a triple resonant RF coil setup for the rat head at 9.4 T is presented for imaging of both nuclei (23Na and 39K) and the acquisition of anatomical proton images in the same experiment without moving the subject or the RF coil. In vivo MR images of 39K and 23Na in the rat brain were acquired as well as anatomical proton images in the same scanning session.  相似文献   

16.
[5-13C,15N]Glutamine, with 1J(13C–15N) of 16 Hz, was observed in vivo in the brain of spontaneously breathing rats by 13C MRS at 4.7 T. The brain [5-13C]glutamine peak consisted of the doublet from [5-13C,15N]glutamine and the center [5-13C,14N]glutamine peak, resulting in an apparent triplet with a separation of 8 Hz. The time course of formation of brain [5-13C,15N]glutamine was monitored in vivo with a time resolution of 20–35 min. This [5-13C,15N]glutamine was formed by glial uptake of released neurotransmitter [5-13C]glutamate and its reaction with 15NH3 catalyzed by the glia-specific glutamine synthetase. The neurotransmitter glutamate C5 was selectively13C-enriched by intravenous [2,5-13C]glucose infusion to 13C-label whole-brain glutamate C5, followed by [12C]glucose infusion to chase 13C from the small and rapidly turning-over glial glutamate pool, leaving 13C mainly in the neurotransmitter [5-13C]glutamate pool, which is sequestered in vesicles until release. Hence, the observed [5-13C,15N]glutamine arises from a coupling between 13C of neuronal origin and 15N of glial origin. Measurement of the rate of brain [5-13C,15N]glutamine formation provides a novel noninvasive method of studying the kinetics of neurotransmitter uptake into glia in vivo, a process that is crucial for protecting the brain from glutamate excitotoxicity.  相似文献   

17.
A method for the quantitation of cerebral metabolites on a clinical MR scanner by natural abundance13C MRSin vivois described. Proton-decoupled spectra were acquired with a power deposition within FDA guidelines using a novel coil design.myo-Inositol, quantified by a separate proton MRS, and readily detectable in13C MRS, was used as an internal reference. Normal concentrations, measured in four control subjects, age 7 months to 12 years, were glutamate 9.9 ± 0.7, glutamine 5.6 ± 1.0, and NAA 8.8 ± 2.8 mmol/kg. In a patient diagnosed with Canavan disease, examined four times, glutamate was reduced to 46% of normal, 4.6 ± 0.5 mmol/kg. NAA was increased by 50% to 13.2 ± 1.6 mmol/kg in13C MRS, consistent with the 41% increase to 12.3 ± 1.1 from control 8.7 ± 1.1 mmol/kg assayed by1H MRS. Limited concentration of glutamate may impact on glutamatergic neurons and excitatory neurotransmission in Canavan disease. Quantitation of cerebral glutamate in human brain may have clinical value in human neuropathologies in which glutamate is believed to play a central role.  相似文献   

18.
Partial volume effects in proton magnetic resonance spectroscopy in the brain have been studied previously in terms of proper water concentration calculations, but there is a lack of disclosure in terms of voxel placement techniques that would affect the calculations. The purpose of this study is to facilitate a fully automated MRS voxel registration method which is time efficient, accurate, and can be extended to all imaging modalities. A total of thirteen healthy adults underwent single voxel 1H-MRS scans in 3.0 T MRI scanners. Transposition of a MRS voxel onto an anatomical scan is derived along with a full calculation of water concentration with a correction term to account for the partial volume effects. Five metabolites (tNAA, Glx, tCr, mI, and tCho) known to yield high reliability are studied. Pearson’s correlation analyses between tissue volume fractions and metabolite concentrations were statistically significant in parietal (tCr, Glx, and tNAA) lobe and occipital lobe (tNAA). MRS voxel overlaps quantified by dice metric over repeated visits yielded 60% ~ 70% and coefficients of variance in metabolites concentration were 4% ~ 10%. These findings reiterate an importance of considering the partial volume effects when tissue water is used as an internal concentration reference so as to avoid misinterpreting a morphometric difference as a metabolic difference.  相似文献   

19.
This study shows how applying compressed sensing (CS) to (19)F chemical shift imaging (CSI) makes highly accurate and reproducible reconstructions from undersampled datasets possible. The missing background signal in (19)F CSI provides the required sparsity needed for application of CS. Simulations were performed to test the influence of different CS-related parameters on reconstruction quality. To test the proposed method on a realistic signal distribution, the simulation results were validated by ex vivo experiments. Additionally, undersampled in vivo 3D CSI mouse datasets were successfully reconstructed using CS. The study results suggest that CS can be used to accurately and reproducibly reconstruct undersampled (19)F spectroscopic datasets. Thus, the scanning time of in vivo(19)F CSI experiments can be significantly reduced while preserving the ability to distinguish between different (19)F markers. The gain in scan time provides high flexibility in adjusting measurement parameters. These features make this technique a useful tool for multiple biological and medical applications.  相似文献   

20.
Abstract

The [13C]aminopyrine breath test ([13C]ABT) measures the global activity of cytochrome P450 in vivo and is a sensitive indicator of liver metabolic dysfunction. The present study aims to determine whether gender and cigarette smoking influence the results of [13C]ABT as well as to confirm the effect of oral contraceptive steroids (OCS) intake on this metabolic test. Hundred and ten healthy subjects, including men and women, smoker and non-smoker, women taking OCS or not, were phenotyped for CYP1A2 using the [13C]caffeine breath test and underwent a [13C]ABT. Both tests showed large inter-individual variations in accordance with that of CYP450 liver content. [13C]ABT was sensitive enough to point out a significant induction or inhibition related to cigarette smoking habits or OCS. The combined effect of smoking and OCS resulted in an overall unchanged metabolic activity. Consequently, the impact of the studied conditions on the [13C]ABT parameters must be considered by clinicians or clinical investigators.  相似文献   