首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Bonneil E  Waldron KC 《Talanta》2000,53(3):687-699
Peptide mapping has been widely used for the identification of modified proteins involved in certain diseases. Despite the fact that capillary electrophoresis (CE) has been shown to be a powerful tool for the separation and detection of tryptic peptide fragments after protein digestion, this technique lacks sensitivity for mapping proteins isolated in very small quantities from biological samples. Consequently, it has been necessary to preconcentrate the protein before adding the proteolytic enzyme for digestion in solution. These experimental steps are quite long, labor intensive and require a lot of sample handling. In this paper, we describe an on-line system allowing digestion of the protein, followed by preconcentration, separation and detection of the tryptic fragments in 4 h. Up to an 800-fold preconcentration factor was achieved for cytochrome c, despite a loss of separation efficiency induced by the multiple-valve design of the system and dispersion of the 60-nl desorption plug. Moreover, our system showed good migration time reproducibility between peptide maps and could be reused for several samples.  相似文献   

2.
In this study, methodology was developed for on-line and miniaturized enzymatic digestion with liquid chromatographic (LC) separation and mass spectrometric (MS) detection. A packed capillary LC-MS system was combined with on-line trypsin cleavage of a model protein, lactate dehydrogenase, to provide an efficient system for peptide mapping. The protein was injected onto an enzymatic capillary reactor and the resulting peptides were efficiently trapped on a capillary trapping column. Different trapping columns were evaluated to achieve a high binding capacity for the peptides generated in the enzyme reactor. The peptides were further eluted from the pre-column and separated on an analytical capillary column by a buffer more suitable for the following an electrospray ionisation (ESI) MS process. An important aspect of the on-line approach was the desalting of peptides performed in the trapping column to avoid detrimental signal suppression in the ESI process. The developed on-line system was finally compared to a classical digestion in solution, with reference to peptide sequence coverage and sensitivity. It was shown that the on-line system gave more than 100% higher peptide sequence coverage than traditional digestion methods.  相似文献   

3.
We describe a two-dimensional capillary electrophoresis system that incorporates a replaceable enzymatic microreactor for on-line protein digestion. In this system, trypsin is immobilized on magnetic beads. At the start of each experiment, old beads are flushed to waste and replaced with a fresh plug of beads, which is captured by a pair of magnets at the distal tip of the first capillary. For analysis, proteins are separated in the first capillary. A fraction is then parked in the reactor to create peptides. Digested peptides are periodically transferred to the second capillary for separation; a fresh protein fraction is simultaneously moved to the reactor for digestion. An electrospray interface is used to introduce peptides into a mass spectrometer for analysis. This procedure is repeated for several dozen fractions under computer control. The system was demonstrated by the separation and digestion of insulin chain b oxidized and β-casein as model proteins.  相似文献   

4.
An enzyme-immobilized capillary microreactor for rapid protein digestion and proteomics analysis is reported. The inner surface of the fused-silica capillary was coated with poly(diallyldimethylammonium chloride) (PDDA)-entrapped silica sol-gel matrix, followed by assembly of trypsin onto the PDDA-modified surface via electrostatic adsorption. The immobilization parameters such as PDDA content in the sol-gel matrix, trypsin concentration and pH were investigated in detail. Protein samples including beta-casein, myoglobin and cytochrome c could be effectively digested and electrophoretically separated simultaneously in such a modified capillary. Just 2.26 ng (corresponding to 0.10-0.14 picomole) of sample was sufficient for on-line capillary electrophoresis peptide mapping. The efficiency of the digestion was further demonstrated by digestion of a human liver cytoplasm sample and 253 proteins were identified in one unique run.  相似文献   

5.
An integrated platform consisting of protein separation by CIEF with monolithic immobilized pH gradient (M‐IPG), on‐line digestion by trypsin‐based immobilized enzyme microreactor (trypsin‐IMER), and peptide separation by CZE was established. In such a platform, a tee unit was used not only to connect M‐IPG CIEF column and trypsin‐IMER, but also to supply adjustment buffer to improve the compatibility of protein separation and digestion. Another interface was made by a Teflon tube with a nick to couple IMER and CZE via a short capillary, which was immerged in a centrifuge tube filled with 20 mmol/L glutamic acid, to exchange protein digests buffer and keep electric contact for peptide separation. By such a platform, under the optimal conditions, a mixture of ribonuclease A, myoglobin and BSA was separated into 12 fractions by M‐IPG CIEF, followed by on‐line digestion by trypsin‐IMER and peptide separation by CZE. Many peaks of tryptic peptides, corresponding to different proteins, were observed with high UV signals, indicating the excellent performance of such an integrated system. We hope that the CE‐based on‐line platform developed herein would provide another powerful alternative for an integrated analysis of proteins.  相似文献   

6.
田苗苗  杨丽 《色谱》2020,38(10):1143-1153
毛细管电泳技术具有操作简单、样品消耗量少、分离效率高和分析速度快等优势,不仅是一种高效的分离分析技术,而且已经发展成为在线酶分析和酶抑制研究的强有力工具。酶反应全程的实时在线监测,可以实现酶反应动力学过程的高时间分辨精确检测,以更准确地获得反应机制和反应速率常数,有助于更好地了解酶反应机制,从而更全面深入地认识酶在生物代谢中的功能。此外,准确、快速的在线酶抑制剂高通量筛选方法的发展,对加快酶抑制类药物的研发以及疾病的临床诊断亦具有重要意义。电泳媒介微分析法(EMMA)和固定化酶微反应器(IMER)是毛细管电泳酶分析技术中常用的在线分析方法。这两种在线酶分析法的进样方式通常为流体动力学进样和电动进样,无法实现酶反应过程中的无干扰序列进样分析。近年来,基于快速序列进样的毛细管电泳序列分析技术已经发展成为在线酶分析的另一种强有力手段,以实现高时间分辨和高通量的酶分析在线检测。该文从快速序列进样的角度,综述了近年来毛细管电泳序列分析技术在线酶分析的研究进展,并着重介绍了各种序列进样方法及其在酶反应和酶抑制反应中的应用,包括光快门进样、流动门进样、毛细管对接的二维扩散进样、流动注射进样、液滴微流控进样等。  相似文献   

7.
宋佳一  李梦琦  沈昊  周梓昕  贺雯婷  苏萍  杨屹 《色谱》2020,38(10):1206-1210
生物酶影响着物质代谢和质能转换等生命活动,生物体内某些酶的活性变化会导致疾病的发生。发展新型的酶分析方法对深刻理解生物代谢过程、疾病诊断和药物研发等具有重要意义。毛细管电泳(CE)具有分离效率高、分析速度快、操作简单和样品消耗少以及可与多种检测手段联用等优点,在酶分析研究中越来越受到关注。CE酶分析主要包括离线和在线两种模式,其中,固定化酶微反应器与毛细管电泳联用(CE-IMER)的在线酶分析已经成为主要的酶分析方法之一。CE-IMER充分结合了固定化酶和CE的优势,将游离酶固定在毛细管内,不仅可以显著提高酶的稳定性和重复使用性,而且可以实现纳升规模溶液的自动化酶分析,进而显著降低酶分析成本。目前已有大量方法制备IMER用于CE酶分析,然而如何构建性能良好、可再生使用、酶固载量大、自动化程度高的CE-IMER一直是该领域重点研究的问题。DNA定向固定化技术(DDI)可以充分利用DNA分子的碱基互补配对(A-T,C-G),在温和的生理条件下特异性固定生物大分子。由于短链双螺旋DNA分子具有较强的机械刚性和物理化学稳定性,通过DDI将酶固定在载体表面,有利于降低传质阻力,提高酶与底物的接触能力,进而促进酶促分析过程。该文主要综述了利用DDI构建新型IMER在CE酶分析中的应用现状,并对其未来发展进行了展望。  相似文献   

8.
Simpson DC  Smith RD 《Electrophoresis》2005,26(7-8):1291-1305
Mass spectrometry (MS)-based proteomics is currently dominated by the analysis of peptides originating either from digestion of proteins separated by two-dimensional gel electrophoresis (2-DE) or from global digestion; the simple peptide mixtures obtained from digestion of gel-separated proteins do not usually require further separation, while the complex peptide mixtures obtained by global digestion are most frequently separated by chromatographic techniques. Capillary electrophoresis (CE) provides alternatives to 2-DE for protein separation and alternatives to chromatography for peptide separation. This review attempts to elucidate how the most promising CE modes, capillary zone electrophoresis (CZE) and capillary isoelectric focusing (CIEF), might best be applied to MS-based proteomics. CE-MS interfacing, mass analyzer performance, column coating to minimize analyte adsorption, and sample stacking for CZE are considered prior to examining numerous applications. Finally, multidimensional systems that incorporate CE techniques are examined; CZE often finds use as a fast, final dimension before ionization for MS, while CIEF, being an equilibrium technique, is well-suited to being the first dimension in automated fractionation systems.  相似文献   

9.
The construction of a sheathless interface for capillary electrophoresis-electrospray ionization mass spectrometry (CE-ESI-MS), for operation with a Z-Spray source on a Micromass Quattro-LC triple quadrupole mass spectrometer is described. Designing the interface involved machining a probe compatible with the setup already in place on the mass spectrometer, i.e., MegaFlow-Z ESI. The probe was made of Lexan with the same dimensions as the ESI probe supplied with the instrument. The electrical connection at the electrospray end of the CE capillary was made possible by gold-coating (sheathless CE-ESI-MS). The probe design as well as the electrical and power supply requirements are described in detail. Experiments were performed using this interface, and CE separations of mixtures containing pmole and sub-pmole amounts of peptides were monitored by on-line MS. For a standard peptide mixture (10(-4) M), separation efficiency was typically characterized by N > 10(4) theoretical plates with S/N > 400. Using the same experimental setup, it was also possible to conduct on-line CE-ESI-tandem MS (MS/MS) experiments on the same peptide mixture, and to determine the sequence of the peptides. MS/MS scan functions for different precursor ions were used either alternately or sequentially and the results from both methods were compared. The possibility of peptide mass mapping was explored, and CE-ESI-MS results were obtained for the digestion products of equine myoglobin. Separation efficiencies and S/N values were similar to those obtained for standard peptides. A complete map of the digestion products was obtained.  相似文献   

10.
A CE method based on a dual‐enzyme co‐immobilized capillary microreactor was developed for the simultaneous screening of multiple enzyme inhibitors. The capillary microreactor was prepared by co‐immobilizing adenosine deaminase and xanthine oxidase on the inner wall at the inlet end of the separation capillary. The enzymes were first immobilized on gold nanoparticles, and the functionalized gold nanoparticles were then assembled on the inner wall at the inlet end of the separation capillary treated with polyethyleneimine. With the developed CE method, the substrates and products were baseline separated within 3 min. The activity of the immobilized enzyme can be directly detected by measuring the peak height of the products. A statistical parameter Z′ factor was recommended for evaluation of the accuracy of a drug screening system. In the present study, it was calculated to be larger than 0.5, implying a good accuracy. Finally, screening a small compound library containing two known enzyme inhibitors and 20 natural extracts by the proposed method was demonstrated. The known inhibitors were identified, and some natural extracts were found to be positive for two‐enzyme inhibition by the present method.  相似文献   

11.
利用羟丙基纤维素溶液动态涂层技术修饰毛细管管壁,改善了分离效率.在不影响质谱检测的条件下,将动态涂层毛细管电泳与质谱检测联用,有效地提高了对蛋白质的鉴定能力.将该技术应用于对复杂蛋白质样品的酶解产物的分析鉴定,结果令人满意.  相似文献   

12.
The preparation and characterization of a new trypsin-based bioreactor is here described for on-line protein digestion and peptide analysis. Trypsin was immobilized on an epoxy-modified silica monolithic support with a single reaction step and the amount of immobilized enzyme was found to be 66.07 mg (+/-11.75 S.D.)/column (n = 6). The bioreactor was coupled through a switching valve to an analytical column for the on-line digestion, peptide separation and identification of test proteins by ESI-MS-MS. The influence of various parameters (flow rate, temperature, buffer pH and molarity, etc.) on enzymatic activity was investigated by an experimental design and the mostly significant factor was found to be the flow rate. The efficacy of the reported on-line bioreactor for tryptic mapping is reported for somatostatin and myoglobin, selected as model compounds. Tryptic peptide maps obtained by on-line digestion of myoglobin were compared to those obtained by traditional off-line digestion. Sequence coverage obtained with the on-line protocol (21 peptides, 75.16% coverage of myoglobin sequence) was found to be comparable to the one obtained with the off-line protocol (18 peptides, 76.47% coverage). Sensitivity for myoglobin digestion and identification was 0.1 mg/ml. The reproducibily of the peptide maps in terms of retention time was from 1.53 to 4.31%, R.S.D.  相似文献   

13.
A technique for separating and detecting enzyme inhibitors was developed using CE with an enzyme microreactor. The on‐column enzyme microreactor was constructed using NdFeB magnet(s) to immobilize alkaline phosphatase‐coated superparamagnetic beads (2.8 μm diameter) inside a capillary before the detection window. Enzyme inhibition assays were performed by injecting a plug of inhibitor into a capillary filled with the substrate, AttoPhos. Product generated in the enzyme microreactor was detected by LIF. Inhibitor zones electrophoresed through the capillary, passed through the enzyme microreactor, and were observed as negative peaks due to decreased product formation. The goal of this study was to improve peak capacities for inhibitor separations relative to previous studies, which combined continuous engagement electrophoretically mediated microanalysis and transient engagement electrophoretically mediated microanalysis to study enzyme inhibition. The effects of electric field strength, bead injection time and inhibitor concentrations on peak capacity and peak width were investigated. Peak capacities were increased to ≥20 under optimal conditions of electric field strength and bead injection time for inhibition assays with arsenate and theophylline. Five reversible inhibitors of alkaline phosphatase (theophylline, vanadate, arsenate, L ‐tryptophan and tungstate) were separated and detected to demonstrate the ability of this technique to analyze complex inhibitor mixtures.  相似文献   

14.
The immobilization conditions and kinetic behaviour of trypsin, covalently immobilized via the 1,4-diisothiocyanatobenzene (DITC) linker onto aminopropylated controlled pore glass (CPG) particles, have been evaluated to establish a rapid and efficient protocol for fabrication of an immobilized enzyme microreactor (IMER) for protein hydrolysis and subsequent peptide mapping. Addition of calcium ions to either the immobilization reaction solution or hydrolysis assay was studied for a synthetic substrate. Activity was slightly higher when immobilization was carried out in the presence of Ca2+ whereas more enzyme could be immobilized in its absence. A protocol requiring less than 3 h was devised to obtain maximal enzymatic activity with the lowest ratio of soluble trypsin to DITC-CPG particles. The resulting immobilized enzyme was found to retain an acceptable percentage (ca. 35%) of its activity after immobilization. The particles were dry-packed into a capillary to make a microscale IMER. Repeatability, reusability and digestion efficiency of the μIMER were investigated for the substrate β-casein using capillary electrophoretic-based peptide mapping. In initial tests, a single device showed reproducible peptide maps for 21 digestions lasting 2 h each, carried out over a period of 2 months. Complete digestion of β-casein could be achieved in a few minutes (86 s residence time in the μIMER followed by a wash step).  相似文献   

15.
利用毛细管作为酶固定化的载体,将酶直接键合到毛细管内壁,制成毛细管纳升反应器,结合质谱分析水解产物,获得了蛋白质的肽谱.实验发现,以毛细管为反应器后,蛋白质肽谱分析所需量大大减少,只需10-13mol,甚至几个10-15mol的量就可满足分析要求.  相似文献   

16.
A study was initiated to construct a micro-reactor for protein digestion based on trypsin-coated fused-silica capillaries. Initially, surface plasmon resonance was used both for optimization of the surface chemistry applied in the preparation and for monitoring the amount of enzyme that was immobilized. The highest amount of trypsin was immobilized on dextran-coated SPR surfaces which allowed the covalent coupling of 11 ng mm−2 trypsin. Fused-silica capillaries were modified in a similar manner and the resulting open-tubular trypsin-reactors having a pH optimum of pH 8.5, display a high activity when operated at 37 °C and are stable for at least two weeks when used continuously. Trypsin auto-digestion fragments, sample carry-over, and loss of signal due to adsorption of the protein were not observed. On-line digestion without prior protein denaturation, followed by micro-LC separation and photodiode array detection, was tested with horse-heart cytochrome C and horse skeletal-muscle myoglobin. The complete digestion of 20 pmol μL−1 horse cytochrome C was observed when the average residence time of the protein sample in a 140 cm ×50 μm capillary immobilized enzyme reactor (IMER) was 165 s. Mass spectrometric identification of the injected protein on the basis of the tryptic peptides proved possible. Protein digestion was favorable with respect to reaction time and fragments formed when compared with other on-line and off-line procedures. These results and the easy preparation of this micro-reactor provide possibilities for miniaturized enzyme-reactors for on-line peptide mapping and inhibitor screening.  相似文献   

17.
Issue no. 2 is a regular issue assembled of 16 solid and original research articles distributed over 3 distinct parts. Part I is on novel trends in fundamentals and methodologies including theoretical models for selectivity of charged solutes in MEKC, system peaks in indirect detection, measuring epimerization constants by MEEKC, bundled CE using micro‐structured fibers, 2‐D separations by coupling CIEF and CEC, high speed DNA CE, MCE of N‐glycans and mucin expression in a microfluidic gradient device. Part II is concerned with detection, sensitivity enhancement, on‐column preconcentration and microdialysis sampling involving the design of continuous full filling CEC‐ESI‐MS using nanoparticles, CE‐fluorescence using tapered optical fiber, CZE separation of pesticide residues in water samples with acid‐assisted on‐column preconcentration and CE‐LIF to detect neurotransmitter amino acids and carbamathione in brain microdialysis samples. Novel methods for the separation and profiling of various proteins and large nucleic fragments are described in 4 consecutive papers grouped in part III. Featured articles include: Theoretical models of separation selectivity for charged compounds in micellar electrokinetic chromatography (( 10.1002/elps.201000405 )) Bundled capillary electrophoresis using microstructured fibres ( 10.1002/elps.201000442 )) Two‐dimensional separation system by on‐line hyphenation of capillary isoelectric focusing with pressurized capillary electrochromatography for peptide and protein mapping ( 10.1002/elps.201000419 )) Microchip electrophoresis of N‐glycans on serpentine separation channels with asymmetrically tapered turns ( 10.1002/elps.201000461 ))  相似文献   

18.
Zhang H  Jin W 《Electrophoresis》2004,25(7-8):1090-1095
A novel method for determining different forms of human interferon-gamma (IFN-gamma) in single natural killer cells was developed by capillary electrophoresis (CE) with on-capillary immunoreaction and laser-induced fluorescence (LIF) detection. Cells were perforated with digitonin and one single cell was electrokinatically introduced into the front end of a separation capillary. The monoclonal antibody labeled with fluorescein isothiocyanate of IFN-gamma was hydrodynamically injected into the front end of the capillary around the cell introduced. After the cell was lysed by ultrasonication, the front end of the capillary was used as a microreactor to allow different forms of IFN-gamma to process the immunoreaction with their labeled antibody. Finally, the complexes of different forms of IFN-gamma with their labeled antibody were separated and detected by CE with LIF detection with a limit of detection of zeptomoles (10(-21) mol).  相似文献   

19.
A novel monolithic enzymatic microreactor was prepared in the fused-silica capillary by in situ polymerization of acrylamide (AA), N-acryloxysuccinimide (NAS) and ethylene dimethacrylate (EDMA) in the presence of a binary porogenic mixture of dodecanol and cyclohexanol, which could offer very low back pressure, enabling the fast digestion of proteins. The performance of the monolithic microreactor was demonstrated by digesting cytochrome c at high flow rate, and the comparisons between the in-solution digestion and on-column reaction were made by a nano-high performance liquid chromatography-mass spectrometry (nano-HPLC-MS) system. The performance of the monolithic microreactor was demonstrated with the digestion of cytochrome c at the fast flow rate of 1 microL/min, which afforded a residence time of 7s, yielding a sequence coverage of 54.81% using strict multiple database searching thresholds. Future more, a mixture of four standard proteins was digested and analyzed using the on-line digestion and nano-HPLC-MS system. The results showed the promising of such a system in the analysis of protein mixture.  相似文献   

20.
A method based on tryptic digestion, ultrafiltration and capillary electrophoresis/mass spectrometry (CE/MS) has been developed for the analysis of the glycosylation pattern in the phospholipase A2 (PLA) of individual honeybees. Without reducing the disulfide bonds, PLA was digested with trypsin and filtered with a 3 kDa molecular weight (MW) cut-off membrane. With this procedure, the glycopeptides could be isolated from the nonglycosylated peptides. After tryptic digestion and ultrafiltration, the disulfide bonds were reduced before analysis by CE. To reduce the adsorption, CE separation was performed on successive multiple ionic-polymer (SMIL) polybrene (PB) coated capillary columns. The SMIL-PB columns allowed partial separation of the glycopeptides and eight glycopeptides were identified by on-line coupling of CE with electrospray ionization (ESI) mass spectrometry. The analysis of phospholipase A2 from the venom of individual bees indicated that the variation and relative abundances of different glycopeptides were similar between the younger and the older bees.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号