首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 125 毫秒
1.
A novel and sensitive method for the determination of five benzotriazole compounds (commonly used as light stabilizers) in indoor dust is presented. Pressurized liquid extraction (PLE) and gas chromatography followed by tandem in time mass spectrometry (GC–MS/MS) were used as sample preparation and determination techniques, respectively. Extraction and clean-up were integrated on-line and, after an evaporative concentration step, the extract provided by the PLE instrument was injected directly in the GC–MS/MS system. Parameters affecting the performance of the sample preparation process were evaluated using experimental factorial designs. Under optimized conditions, analytes were recovered from 0.5 g samples in 3 static extraction cycles of 10 min, using a hexane:dichloromethane (7:3) mixture, at 90 °C. Silica (1 g) was placed in the bottom of the extraction cells as clean-up sorbent. The recoveries of the method varied from 82 to 122%, with standard deviations below 13. The inter-day precision ranged from 9 to 12%, and the limits of quantification (LOQs) remained below 10 ng g−1 for all species. For the first time, four of the five investigated species were found in dust from indoor environments. Their mean concentrations ranged from 71 to 780 ng g−1.  相似文献   

2.
A novel method based on ultrasonic solvent extraction and stir bar sorptive extraction for the analysis of phenolic organic pollutants including chlorophenols, bisphenol-A, 4-tert-octylphenol and 4-nonylphenol in soil samples was developed. The different parameters that affect both the extraction of analytes from the soil samples, such as solvent selection, extraction time, and the partitioning from the solvent/water mix to poly(dimethylsiloxane) (PDMS) were studied. The final selected conditions consisted of the extraction of 1 g of soil with 15 mL methanol by sonication for 30 min. The methanol extract was mixed with 85 mL of Milli-Q water and extracted by means of stir bar sorptive extraction with in situ derivatisation. The stir bars were analyzed by thermal desorption–gas chromatography–mass spectrometry (TD–GC–MS). The effects of the matrix on the recovery of the various pollutants under the developed method were studied using two soils with very different physicochemical properties. Method sensitivity, linearity, repeatability, and reproducibility were also studied. Validation and accuracy of the method were conducted by analyzing two commercial certified reference materials and by comparing the analysis of real samples with the proposed method and a classical method using pressurized solvent extraction (PSE)–GC–MS. The main advantage of this method is a substantial solvent reduction. For the extraction of only 1 g of solid sample allowing limits of detection ranging from 0.2 to 1.7 μg kg−1 dw. Repeatability and reproducibility variation were lower than 20% for all investigated compounds. Results of the certified reference materials and the real samples verify the high accuracy of this method.  相似文献   

3.
A new, single-step extraction and purification method based on matrix solid-phase dispersion (MSPD) was developed to determine 17 polycyclic aromatic hydrocarbons (PAHs) in sewage sludge samples. The MSPD method consists of sample homogenisation, exhaustive extraction and clean-up by a single process. The different operational parameters of the method, such as the type of dispersant, type and amount of additives, clean-up co-sorbent and extractive solvent were evaluated. Reversed-phase (C18) and polymeric (Oasis HLB and Oasis MAX) materials, as well as normal phase sorbents (Florisil, silica, neutral alumina) and an inert support (sand) were tested to assess the sorbents effect on the yield and selectivity of the MSPD process. Analysis of extracts was performed by high performance liquid chromatography (HPLC) coupled with fluorescence detection.Quantification limits obtained for all of these considered compounds (between 0.0001 and 0.005 μg g−1 dry mass) were well below of the limits recommended in the EU. The extraction yields for the different compounds obtained by MSPD ranged from 76.3% to 103.6%. On the other hand, the extraction efficiency of the optimised method is compared with that achieved by microwave-assisted extraction and the method was applied to the analysis of real sewage sludge samples. A certified reference material (sewage sludge (BCR 088)) and a reference material (sewage sludge (RTC-CNS312-04)) were used to validate the proposed method.  相似文献   

4.
In this work, a headspace-solid-phase micro-extraction (HS-SPME) combined with gas chromatography–mass spectrometry (GC–MS) method for multielemental speciation of organometallic compounds of mercury, lead and tin in water samples was upgraded by the introduction of tandem mass spectrometry (MS/MS) as detection technique. The analytical method is based on the ethylation with NaBEt4 and simultaneous headspace-solid-phase micro-extraction of the derivative compounds followed by GC–MS/MS analysis. The main experimental parameters influencing the extraction efficiency such as derivatisation time, extraction time and extraction temperature were optimized. The overall optimum extraction conditions were the following: a 50 μm/30 μm divinyl-benzene/carboxen/polydimethylsiloxane (DVB/CAR/PDMS) SPME fibre, 150 min derivatisation time, 15 min extraction time, sample agitation at 250 rpm and 40 °C extraction temperature. The analytical characteristics of the HS-SPME method combined with GC–MS and GC–MS/MS were evaluated. The combination of both techniques HS-SPME and GC–MS/MS allowed to attain lower limits of detection (4–33 ng l−1) than those obtained by HS-SPME–GC–MS (17–45 ng l−1). The proposed method presented good linear regression coefficients (r2 > 0.9970) and repeatability (4.8–21.0%) for all the compounds under study. The accuracy of the method measured as the average percentage recovery of the compounds in spiked river water and seawater samples was higher than 80% for all the compounds studied, except for monobutyltin in the river water sample. A study of the uncertainty associated with the analytical results was also carried out.  相似文献   

5.
Sensitive and reliable methods have been developed and validated for determination of commonly consumed azole antifungal pharmaceuticals (clotrimazole, econazole, ketoconazole, and miconazole) and biocides (propiconazole and tebuconazole) in various waters and sewage sludge. Solid phase extraction (SPE) combined with ultra-high performance liquid chromatography–tandem mass spectrometry (UHPLC–MS/MS) was used to determine the azole antifungals in waters. Azole antifungals in sewage sludge were extracted with ultrasonic-assisted extraction, followed by SPE cleanup and UHPLC–MS/MS detection. Quantification was performed by internal standard calibration in multiple reaction monitoring mode. Recoveries were mostly in the range of 52–110% with relative standard deviations generally within 20%. Method quantification limits were 0.5–6 ng L−1 in waters and 3–9 ng g−1 dry weight (dw) in sewage sludge, respectively. The methods were applied to determine the azole antifungals in wastewater, river water, sediment, and sewage sludge sampled from the Pearl River Delta, China. Clotrimazole, ketoconazole, and miconazole were widely detected at low ng L−1 in waters, low ng g−1 dw in river sediment, and low μg g−1 dw in sewage sludge. The methods can provide valuable tools for investigating occurrence and fate of the azole antifungals in the environment.  相似文献   

6.
An extraction and preconcentration procedure for the determination in water samples of several halogenated flame retardants (FRs), nine brominated diphenyls ethers (BDEs) and seven non-BDE FRs, was developed and validated. The optimised procedure is based on polydimethylsiloxane (PDMS) rods as sorptive extraction material, followed by liquid desorption and gas chromatography coupled to negative chemical ionisation–mass spectrometry (GC–NCI–MS) determination, rendering an efficient and inexpensive method. The final optimised protocol consists of overnight extraction of 100 mL of sample solutions containing 40% MeOH and 4% NaCl, followed by a 15-min sonication-assisted desorption with 300 μL of ethyl acetate, solvent evaporation and GC–NCI–MS analysis. Under these conditions, extraction efficiencies in the 9 to 70% range were obtained, leading to enrichment factors between 108 and 840, detection limits in the range from 0.4 to 10 ng L−1and RSD values in the 2–23% range. After method validation, different real water samples, including river, ria, sea, landfill leachate, influent and effluent wastewater from an urban sewage treatment plant (STP) and effluent wastewater from a textile industry, were analysed. BDE-47, BDE-99, BDE-100 and BDE-197 were detected in wastewater and landfill leachate samples at concentration levels up to 2887 ng L−1. Among the non-BDE FRs, bis (2-ethylhexyl)-3,4,5,6-tetrabromo-phthalate (DEHTBP) was detected in surface water samples (sea, river and ria) between 1.3 and 2.2 ng L−1 and 1,2-bis(2,4,6-tribromophenoxy)ethane (BTBPE) in the landfill leachate (64 ng L−1).  相似文献   

7.
A method for the determination of 11 UV-filter compounds in sludge has been developed and evaluated. The procedure includes the use of non-porous polymeric membranes in combination with pressurised liquid extraction (PLE). Firstly, the solid sample, wetted with the extraction solvent, was enclosed into tailor-made bags prepared with low density polyethylene. Secondly, these packages were submitted to a conventional PLE (70 °C, 4 cycles of 5 min static time). Finally, the analytes were determined by liquid chromatography–atmospheric pressure photoionisation–tandem mass spectrometry. The main advantage of this procedure is the reduction of time, solvent and labour effort ought to the combination of extraction and clean-up in a single step. Although the extraction is not quantitative (thus, standard addition is recommended for quantification) selectivity is clearly gained using the membrane as a consequence of the differences of permeation and transport through the membrane between the analytes and other sample matrix components. The optimised protocol provides limits of detection ranging from 0.3 ng g−1 (ethylhexyl dimethyl p-aminobenzoate (OD-PABA)) to 25 ng g−1 (ethylhexyl triazone (EHT)) with only 0.5 g of sludge sample. All the studied UV filters were found in the samples at concentration levels between 1.4 and 2479 ng g−1, emphasising the high adsorption potential of this kind of environmental pollutants onto solid samples such as sludge. Also, this method has permitted the determination of seven of the studied UV filters in sludge samples for the first time.  相似文献   

8.
The volatile components of Iranian saffron were extracted using ultrasonic solvent extraction (USE) technique and then were separated and detected by gas chromatography–mass spectrometry (GC–MS). Variables affecting the extraction procedure were screened by using a 25−1 fractional factorial design and among them; sample amount, solvent volume, solvent ratio and extraction time were optimized by applying a rotatable central composite design (CCD). The optimum values of factors were: 2.38 g sample, 29.04 mL solvent, 69.23% MeOH solvent ratio and 71.8 min for the extraction time. Forty constituents were identified for Iranian saffron by GC–MS representing 90% of the total peak area. The major components were 2,6,6-trimethyl-1,3-cyclohexadiene-1-carboxaldehyde, namely safranal (26.29%), bicyclo[3,2,0]hept-2-ene-,4-ethoxy-,endo (5.69%), linoleic acid (4.77%), 4-hydroxy-2,6,6-trimethyl-1-cyclohexene-1-carboxaldehyde, namely HTCC (4.44%), and nonadecanol (3.32%). Some new compounds were identified for the first time in saffron. In addition, the results of this study were compared with those of Greek saffron.  相似文献   

9.
The complex aroma of wine is derived from many sources, with grape-derived components being responsible for the varietal character. The ability to monitor grape aroma compounds would allow for better understanding of how vineyard practices and winemaking processes influence the final volatile composition of the wine. Here, we describe a procedure using GC–MS combined with headspace solid-phase microextraction (HS-SPME) for profiling the free volatile compounds in Cabernet Sauvignon grapes. Different sample preparation (SPME fiber type, extraction time, extraction temperature and dilution solvent) and GC–MS conditions were evaluated to optimize the method. For the final method, grape skins were homogenized with water and 8 ml of sample were placed in a 20 ml headspace vial with addition of NaCl; a polydimethylsiloxane SPME fiber was used for extraction at 40 °C for 30 min with continuous stirring. Using this method, 27 flavor compounds were monitored and used to profile the free volatile components in Cabernet Sauvignon grapes at different maturity levels. Ten compounds from the grapes, including 2-phenylethanol and β-damascenone, were also identified in the corresponding wines. Using this procedure it is possible to follow selected volatiles through the winemaking process.  相似文献   

10.
This paper describes a method for the determination of a group of personal care products including four UV filters, four preservatives and two antimicrobials in sewage sludge. The method combines pressurized liquid extraction and ultra high performance liquid chromatography–tandem mass spectrometry. Most of the parameters that affect the extraction step such as temperature, pressure, static extraction time, number of cycles, purge time and flush volume were optimized using a fractional experimental design. In the chromatographic step, the compounds were detected by using tandem mass spectrometry with a triple quadrupole analyzer with electrospray ionization in positive and negative modes. The use of small diameter particles (1.8 μm) in the chromatographic column allowed the compounds to be eluted in 9 min. The entire process took a total of 39 min. All recoveries were higher than 72% except for 2,4-dihydroxybenzophenone (a UV filter), whose recovery was 30%. The repeatability and reproducibility between days expressed as RSD (%) (n = 3) were less than 8% and 13%, respectively. The LODs and LOQs were lower than 8 μg/kg and 12.5 μg/kg of dry weight (d.w.), respectively. When the method was applied to determine the compounds in sewage sludge from a domestic sewage treatment plant, triclosan (an antimicrobial) and octocrylene (a UV filter) showed the highest levels, 1490 μg/kg (d.w.) and 1842 μg/kg (d.w.), respectively. This paper describes for the first time the determination of parabens and two UV filters (octyldimethyl-p-aminobenzoic acid and benzophenone-3) in sewage sludge.  相似文献   

11.
Analysis of 11 polybrominated diphenyl ethers (PBDEs), tetrabromobisphenol A bis 2,3-dibromopropylether (TBBPA-bis), tetrachlorobisphenol A (TCBPA), tetrabromobisphenol A (TBBPA) and hexabromocyclododecanes (HBCDs) was optimized by ultrahigh pressure liquid chromatography/tandem mass spectrometry (UPLC–MS/MS) operating in negative ion (NI) mode. Electrospray ionization (ESI), atmospheric pressure photoionization (APPI) and atmospheric pressure chemical ionization (APCI) sources were tested and for PBDEs APCI gave higher sensitivity than APPI while for TBBPA-bis APCI and APPI showed similar performance. ESI was the best option for TCBPA, TBBPA and HBCDs. Detection limits were between 20 and 59 fg for the compounds analyzed by ESI, 0.10 and 0.72 pg for PBDEs and 6 pg for TBBPA-bis. The matrix effect of sewage sludge extract was also tested showing negligible ion suppression for APCI and an increase of the background level of all investigated pollutants leading to a worsening of the limits of quantification by a factor between 1.2 and 3.3. The UPLC-APCI/MS/MS method for PBDEs, after pressurized liquid extraction (PLE), was validated by comparison with the concentration values from the NIST 1944 standard reference material. The advantages of the methods include low detection limits, PBDE congeners specificity using selected multiple reaction monitoring (MRM) transitions, and the absence of thermal degradation of higher PBDE congeners, especially BDE-209. The methods were applied for the determination of the above reported flame retardants in sewage sludge in order to get more information about the degradation on PBDEs (in particular BDE-209) during municipal wastewater treatments.  相似文献   

12.
Supercritical carbon dioxide (scCO2) extraction was applied for the determination of microbial phospholipid fatty acids (PLFA) in activated sludge. Quantification was performed by using gas chromatography–mass spectrometry (GC–MS). The highest extraction yields of PLFA, at a concentration of 7.28 nmol/mg-dry activated sludge, was obtained at a temperature of 80 °C, pressure of 25 MPa and 10% (v/v) methanol for a 15-min extraction time. ScCO2 extraction results obtained in these conditions were comparable with those obtained by liquid organic solvent extraction (LSE) based on diversity and equalibility indices. The repeatability test showed that the relative standard deviation values were less than 13%. The experimental results show that the scCO2 extraction saves time and uses much less organic solvent. In addition, scCO2 extraction is a promising and alternative method for the analysis of microbial community structure in environmental assessment using the PLFA profile.  相似文献   

13.
A novel microextraction technique, air-assisted liquid–liquid microextraction (AALLME), which is a new version of dispersive liquid–liquid microextraction (DLLME) method has been developed for extraction and preconcentration of phthalate esters, dimethyl phthalate (DMP), diethyl phthalate (DEP), di-iso-butyl phthalate (DIBP), di-n-butyl phthalate (DNBP), and di-2-ethylhexyl phthalate (DEHP), from aqueous samples prior to gas chromatography–flame ionization detection (GC–FID) analysis. In this method, much less volume of an organic solvent is used as extraction solvent in the absence of a disperser solvent. Fine organic droplets were formed by sucking and injecting of the mixture of aqueous sample solution and extraction solvent with a syringe for several times in a conical test tube. After extraction, phase separation was performed by centrifugation and the enriched analytes in the sedimented phase were determined by GC–FID. Under the optimum extraction conditions, the method showed low limits of detection and quantification between 0.12–1.15 and 0.85–4 ng mL−1, respectively. Enrichment factors (EFs) and extraction recoveries (ERs) were in the ranges of 889–1022 and 89–102%, respectively. The relative standard deviations (RSDs) for the extraction of 100 ng mL−1 and 500 ng mL−1 of each phthalate ester were less than 4% for intra-day (n = 6) and inter-days (n = 4) precision. Finally some aqueous samples were successfully analyzed using the proposed method and three analytes, DIBP, DNBP and DEHP, were determined in them at ng mL−1 level.  相似文献   

14.
A novel approach for the determination of seven fungicides (metalaxyl-M, penconazole, folpet, diniconazole, propiconazole, difenoconazole and azoxystrobin) in wine samples is presented. Analytes were extracted from the matrix and transferred to a small volume of a high density, water insoluble solvent using solid-phase extraction (SPE) followed by dispersive liquid–liquid microextraction (DLLME). Variables affecting the performance of both steps were thoroughly investigated (metalaxyl-M was not included in some optimisation studies) and their effects on the selectivity and efficiency of the whole sample preparation process are discussed. Under optimised conditions, 20 mL of wine were first concentrated using a reversed-phase sorbent and then target compounds were eluted with 1 mL of acetone. This extract was mixed with 0.1 mL of 1,1,1-trichloroethane (CH3CCl3) and the blend added to 10 mL of ultrapure water. After centrifugation, an aliquot (1–2 μL) of the settled organic phase was analyzed by gas chromatography (GC) with electron capture (ECD) and mass spectrometry (MS) detection. The method provided enrichment factors (EFs) around 200 times and an improved selectivity in comparison to use of SPE as single sample preparation technique. Moreover, the yield of the global process was similar for red and white wine samples and the achieved limits of quantification (LOQs) (from 30 to 120 ng L−1 and from 40 to 250 ng L−1, for GC–ECD and GC–MS, respectively) were low enough for the determination of target species in commercial wines. Among compounds considered in this work, metalaxyl-M and azoxystrobin were found in several wines at concentrations from 0.8 to 32 ng mL−1.  相似文献   

15.
A new analytical method based on simultaneous derivatization and dispersive liquid–liquid microextraction (DLLME) followed by gas chromatography–mass spectrometry (GC–MS), for the determination of the allergenic compounds atranol and chloroatranol in perfumes, is presented. Derivatization of the target analytes by means of acetylation with anhydride acetic in carbonate buffer was carried out. Thereby volatility and detectability were increased for improved GC–MS sensitivity. In addition, extractability by DLLME was also enhanced due to a less polar character of the solutes. A liquid–liquid extraction was performed before DLLME to clean up the sample and to obtain an aqueous sample solution, free of the low polar matrix from the essential oils, as donor phase. Different parameters, such as the nature and volume of both the extraction and disperser solvents, the ionic strength of the aqueous donor phase or the effect of the derivatization reagent volume, were optimized. Under the selected conditions (injection of a mixture of 750 μL of acetone as disperser solvent, 100 μL of chloroform as extraction solvent and 100 μL of anhydride acetic as derivatization reagent) the figures of merit of the proposed method were evaluated. Limits of detection in the low ng mL−1 range were obtained. Matrix effect was observed in real perfume samples and thus, standard addition calibration is recommended.  相似文献   

16.
A new analytical method for the determination of four hydroxylated benzophenone UV filters (i.e. 2-hydroxy-4-methoxybenzophenone (HMB), 2,4-dihydroxybenzophenone (DHB), 2,2′-dihydroxy-4-methoxybenzophenone (DHMB) and 2,3,4-trihydroxybenzophenone (THB)) in sea water samples is presented. The method is based on dispersive liquid–liquid microextraction (DLLME) followed by gas chromatography–mass spectrometry (GC–MS) determination. The variables involved in the DLLME process were studied. Under optimized conditions, 1000 μL of acetone (disperser solvent) containing 60 μL of chloroform (extraction solvent) were injected into 5 mL of aqueous sample adjusted to pH 4 and containing 10% NaCl. Before injecting into the GC–MS system, the DLLME extracts were evaporated under an air stream and then reconstituted with N,O-bis-(trimethylsilyl)trifluoroacetamide (BSTFA), thus allowing the target analytes to be converted into their trimethylsilyl derivatives. The best conditions for the derivatization reaction were 75 °C and 30 min. High enrichment factors for all the target analytes (ranging from 58 to 64) and good repeatability (RSD around 6%) were obtained. The limits of detection were in the range of 32–50 ng L−1, depending on the analyte. The recoveries obtained by using the proposed DLLME–GC–MS method evidenced the presence of matrix effects for some of the target analytes, and thereby the standard addition calibration method was employed. Finally, the validated method was applied to the analysis of sea water samples.  相似文献   

17.
A low toxic dispersive liquid–liquid microextraction (LT-DLLME) combined with gas chromatography–mass spectrometry (GC–MS) had been developed for the extraction and determination of 16 polycyclic aromatic hydrocarbons (PAHs) in water samples. In normal DLLME assay, chlorosolvent had been widely used as extraction solvents; however, these solvents are environmental-unfriendly. In order to solve this problem, we proposed to use low toxic bromosolvent (1-bromo-3-methylbutane, LD50 6150 mg/kg) as the extraction solvent. In this study we compared the extraction efficiency of five chlorosolvents and thirteen bromo/iodo solvents. The results indicated that some of the bromo/iodo solvents showed better extraction and had much lower toxicity than chlorosolvents. We also found that propionic acid is used as the disperser solvent, as little as 50 μL is effective. Under optimum conditions, the range of enrichment factors and extraction recoveries of tap water samples are ranging 372–1308 and 87–105%, respectively. The linear range is wide (0.01–10.00 μg L−1), and the limits of detection are between 0.0003 and 0.0078 μg L−1 for most of the analytes. The relative standard deviations (RSD) for 0.01 μg L−1 of PAHs in tap water were in the range of 5.1–10.0%. The performance of the method was gauged by analyzing samples of tap water, sea water and lake water samples.  相似文献   

18.
One-step in situ microwave-assisted headspace solid-phase microextraction (MA-HS-SPME) followed by gas chromatography–mass spectrometry (GC–MS) analysis is presented as a fast and solvent-free technique to determine synthetic polycyclic musks in sewage sludge and sediment samples. Six synthetic polycyclic musks (galaxolide (HHCB), tonalide (AHTN), celestolide (ADBI), traseolide (ATII), cashmeran (DPMI) and phantolide (AHMI)) were selected in the method development and validation. The effects of extraction parameters for the quantitative extraction of these analytes by one-step MA-HS-SPME were systematically investigated. The dewatered solid sample mixed with 20-mL deionized water (containing 3 g of NaCl in a 40-mL sample-vial) was efficiently extracted by a polydimethylsiloxane-divinylbenzene (PDMS-DVB) fiber placed in the headspace when the extraction slurry was microwave irradiated at 80 W for 5 min. The limits of detection (LODs) ranged from 0.04 to 0.1 ng/g, and the limits of quantification (LOQs) ranged from 0.1 to 0.3 ng/g (fresh weight). A preliminary analysis of sludge and sediment samples revealed that HHCB and AHTN were the two most commonly detected synthetic polycyclic musks; using a standard addition method, their total concentrations were determined to range from 0.3 to 10.9 ng/g (fresh weight) with relative standard deviation (RSD) ranging from 4% to 10%.  相似文献   

19.
A less time-, solvent- and sorbent-consuming analytical methodology for the determination of bisphenol A and alkylphenols (4-tert-octylphenol, 4-octylphenol, 4-n-nonylphenol, nonylphenol) in marine sediment was developed and validated. The method was based on selective pressurized liquid extraction (SPLE) with a simultaneous in cell clean up combined with liquid chromatography-electrospray ionization tandem mass spectrometry in negative mode (LC-ESI-MS/MS). The SPLE extraction conditions were optimized by a Plackett–Burman design followed by a central composite design. Quantitation was performed by standard addition curves in order to correct matrix effects. The analytical features of the method were satisfactory: relative recoveries varied between 94 and 100% and repeatability and intermediate precision were <6% for all compounds. Uncertainty assessment of measurement was estimated on the basis of an in-house validation according to EURACHEM/CITAC guide. Quantitation limits of the method (MQL) ranged between 0.17 (4-n-nonylphenol) and 4.01 ng g−1 dry weight (nonylphenol). Sensitivity, selectivity, automaticity and fastness are the main advantages of this green methodology. As an application, marine sediment samples from Galicia coast (NW of Spain) were analysed. Nonylphenol and 4-tert-octylphenol were measured in all samples at concentrations between 20.1 and 1409 ng g−1 dry weight, respectively. Sediment toxicity was estimated and no risk to aquatic biota was found.  相似文献   

20.
In this study, the feasibility of GC–MS was evaluated for the quantification of odorous volatile organic compounds (VOCs) in environmental samples. These included methyl ethyl ketone, isobutyl alcohol, methyl isobutyl ketone, and butyl acetate plus benzene, toluene, and xylene (BTX). For this purpose, the gaseous standard for these VOCs were analyzed by GC–MS with the aid of both direct injection (DI) into the GC injector and solid-phase microextraction (SPME). The liquid phase standard prepared independently was tested additionally by the DI method as a reference to gaseous calibration. The detection limit (DL) values, when tested for basic quality assurance in this study, showed large differences between DI (0.002–0.007 ng) and SPME method (1.03–1.81 ng) in terms of absolute mass. The DL values, when expressed in terms of concentration (v/v), showed considerable improvement in SPME (below 0.40 nmol mol−1) relative to the DI method (∼6–15 nmol mol−1). The reliability of the GC–MS method was further validated through an analysis of real environmental samples collected from an industrial area.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号