1.
Lu X  Liu D  Du J  Wang H  Xue Z  Liu X  Zhou X 《The Analyst》2012,137(3):588-594
The novel phenomenon of cathodic electrochemiluminescence on a gold electrode in tris(bipyridine) ruthenium(II) (Ru(bpy)(3)(2+)) solution is described for the first time. A cathodic electrochemiluminescence (ECL) was found to mainly occur at 0.4-0.8 V with continuous potential scanning from 0.2-1.4 V and the ECL peak was observed around 0.68 V, which was quite different from generally reported Ru(bpy)(3)(2+) ECL. Our group speculated that Ru(bpy)(3)(2+) possibly reacts with the gold electrode in the acidic phosphate buffer solution (PBS) to generate luminescence. The possible ECL mechanism was discussed according to the presented results. Moreover, it is revealed that the Au as co-reactant in the Ru-system contributed dominantly to the whole ECL. Therefore, the reaction between Ru(bpy)(3)(2+) and the newly formed Au implied that the inert metal Au could become a promising material for ECL investigations.  相似文献   

2.
Lu X  Wang H  Du J  Huang B  Liu D  Liu X  Guo H  Xue Z 《The Analyst》2012,137(6):1416-1420
Electrochemiluminescence (ECL) of Ru(bpy)(3)(2+) using metabolites of catecholamines: homovanillic acid (HVA) and vanillylmandelic acid (VMA) as co-reactants were investigated in aqueous solution for the first time. When HVA and VMA were co-existent in the buffer solution containing Ru(bpy)(3)(2+), ECL peaks were observed at a potential corresponding to the oxidation of Ru(bpy)(3)(2+), and the ECL intensity was increased noticeably when the concentrations of HVA and VMA were at lower levels. The linear calibration range was from 8.0 × 10(-5) to 1.0 × 10(-9) M for HVA and VMA. The detection limit (S/N = 3) of HVA and VMA was 4.0 × 10(-10) M. The formation of the excited state Ru(bpy)(3)(2+*) was confirmed to result from the reaction between Ru(bpy)(3)(3+) and the intermediates of HVA or VMA radicals. Moreover, it was found that the ECL intensity was quenched significantly when the concentrations of HVA and VMA were relatively higher. The mechanism of self-quenching processes involved in the Ru(bpy)(3)(2+)-HVA and -VMA ECL systems are proposed in this study.  相似文献   

3.
It was found that stannous chloride (SnCl(2)), as a popular inorganic reducing reagent, could obviously enhance the electrochemiluminescence (ECL) of tris(2,2'-bipyridyl) ruthenium(II) (Ru(bpy)(3)(2+)) in aqueous solution. Some factors affecting the ECL reactions between Ru(bpy)(3)(2+) and Sn(2+), including pH, concentrations of coreactant, and electrode materials, were investigated by comparison with a classic ECL coreactant tripropylamine (TPA). The Ru(bpy)(3)(2+)-Sn(2+) ECL coreactant system produces stronger and more stable ECL signals, can keep its excellent ECL activity over a wider pH range and has more choices in using electrode materials than the Ru(bpy)(3)(2+)-TPA ECL coreactant system. The ECL mechanism of the Ru(bpy)(3)(2+)-Sn(2+) coreactant system was also studied in detail.  相似文献   

4.
Li J  Huang M  Liu X  Wei H  Xu Y  Xu G  Wang E 《The Analyst》2007,132(7):687-691
The electrochemiluminescence (ECL) of tris(2,2'-bipyridyl)ruthenium(II) [Ru(bpy)(3)(2+)] ion-exchanged in the sulfonic-functionalized MCM-41 silicas was developed with tripropylamine (TPrA) as a co-reactant in a carbon paste electrode (CPE) using a room temperature ionic liquid (IL) as a binder. The sulfonic-functionalized silicas MCM-41 were used for preparing an ECL sensor by the electrostatic interactions between Ru(bpy)(3)(2+) cations and sulfonic acid groups. We used the IL as a binder to construct the CPE (IL-CPE) to replace the traditional binder of the CPE (T-CPE)--silicone oil. The results indicated that the MCM-41-modified IL-CPE had more open structures to allow faster diffusion of Ru(bpy)(3)(2+) and that the ionic liquid also acted as a conducting bridge to connect TPrA with Ru(bpy)(3)(2+) sites immobilized in the electrode, resulting in a higher ECL intensity compared with the MCM-41-modified T-CPE. Herein, the detection limit for TPrA of the MCM-41-modified IL-CPE was 7.2 nM, which was two orders of magnitude lower than that observed at the T-CPE. When this new sensor was used in flow injection analysis (FIA), the MCM-41-modified IL-CPE ECL sensor also showed good reproducibility. Furthermore, the sensor could also be renewed easily by mechanical polishing whenever needed.  相似文献   

5.
Guo W  Yuan J  Li B  Du Y  Ying E  Wang E 《The Analyst》2008,133(9):1209-1213
A unique multilabeling at a single-site protocol of the Ru(bpy)(3)(2+) electrochemiluminescence (ECL) system is proposed. Nanoparticles (NPs) were used as assembly substrates to enrich ECL co-reactants of Ru(bpy)(3)(2+) to construct nanoscale-enhanced ECL labels. Two different kinds of NP substrates [including semiconductor NPs (CdTe) and noble metal NPs (gold)] capped with 2-(dimethylamino)ethanethiol (DMAET) [a tertiary amine derivative which is believed to be one of the most efficient of co-reactants of the Ru(bpy)(3)(2+) system] were synthesized through a simple one-pot synthesis method in aqueous media. Although both CdTe and gold NPs realized the enrichment of ECL co-reactants, they presented entirely different ECL performances as nanoscale ECL co-reactants of Ru(bpy)(3)(2+). The different effects of these two NPs on the ECL of Ru(bpy)(3)(2+) were studied. DMAET-capped CdTe NPs showed enormous signal amplification of Ru(bpy)(3)(2+) ECL, whereas DMAET-capped gold NPs showed a slight quenching effect of the ECL signal. DMAET-capped CdTe NPs can be considered to be excellent nanoscale ECL labels of the Ru(bpy)(3)(2+) system, as even a NP solution sample of 10(-18) M was still detectable after an electrostatic self-assembly concentration process. DMAET-capped CdTe NPs were further applied in the construction of aptamer-based biosensing system for proteins and encouraging results were obtained.  相似文献   

6.
We describe the influence of dissolved oxygen on the emission of Ru(bpy)3(2+) (bpy = 2,2'-bipyridine) by electrogenerated chemiluminescence (ECL) with tertiary amine as coreactant in aqueous solutions. The significance of the reactions between molecular oxygen and the ECL intermediate reducing radicals has been demonstrated for the first time. By varying the experimental conditions, the oxygen effect on different ECL routes of the Ru(bpy)3(2+)/tri-n-propylamine (TPrA) system was examined. When coreactant direct oxidation played a predominant role in producing ECL, the maximum emission intensity, especially that of the low-oxidation-potential (LOP) ECL, could change from O2-insensitive to highly O2-sensitive with decreasing TPrA concentration. This behavior can be interpreted as follows: A large excess of intermediate reducing radicals was produced at high [TPrA], and the dissolved oxygen within the ECL reaction layer was completely reduced by these radicals and exerted no quenching effect on the emission. At low [TPrA], however, coreactant oxidation generated a relatively small amount of reducing intermediates, and molecular oxygen acted as an interceptor, destroying the intermediates before they participated in the ECL pathways, which led to the obvious reduction of the emission intensity. In the latter case, the less efficient LOP ECL route was more remarkably affected. When ECL was generated primarily via the catalytic route at high [Ru(bpy)3(2+)], the reactions consuming the intermediate radicals by O2 became insignificant, and he drop of emission intensity in the presence of oxygen could mainly be ascribed to the excited-state quenching. A similar oxygen effect was also observed for the Ru(bpy)3(2+)/triethylamine (TEA) system.  相似文献   

7.
Wang J  Yang Z  Wang X  Yang N 《Talanta》2008,76(1):85-90
Tris(2,2'-bipyridyl) ruthenium(II) (Ru(bpy)(3)(2+))-roxithromycin based electrochemiluminescence (ECL) was enhanced greatly by gold nanoparticles 10 nm in diameter. Capillary electrophoresis (CE) was coupled with the resultant ECL system as a detector for roxithromycin. This ECL emission is explained by the coreactant mechanism where roxithromycin behaves as a coreactant to generate strong reducing species and gold nanoparticles act as "floating nanoelectrodes". The reaction of Ru(bpy)(3)(3+) with the generated strong reducing species on the Pt working electrode as well as on "floating nanoelectrodes" releases Ru(bpy)(3)(2+*), resulting in enhancement of ECL emission. The selectivity of this detection system towards roxithromycin was examined by CE. Under the optimized conditions, the intensity of ECL emission varies linearly with the concentration of roxithromycin from 24 nM to 0.24 mM. The detection limit is 8.4 nM, while without adding gold nanoparticles it is only 84 nM. The detection of roxithromycin in pharmaceutical and urine samples was also performed by the proposed CE-ECL method.  相似文献   

8.
Mao L  Yuan R  Chai Y  Zhuo Y  Jiang W 《The Analyst》2011,136(7):1450-1455
The potential controlling silver catalysis for Ru(bpy)(3)(2+) electrochemiluminescence (ECL) signal at a special potential -0.4~1.25 V was newly developed as the new ECL signal amplification strategy for ultrasensitive protein detection. Firstly, the wheat-like deposited silver (DpAg) particles were modified on the bare glass carbon electrode (GCE) surface by cyclic voltammetry deposition to capture the primary antibodies and then bind the antigen analytes. Secondly, as a sandwich immunoreaction format, the secondary antibodies conjugated with the Ru(bpy)(3)(2+)-doped Pt (Pt@Ru) nanoparticles by the multi-sites biotin/streptavidin (SA) affinity can be captured onto the electrode surface to generate ECL signal. In the proposed Ru(bpy)(3)(2+) ECL system without any co-reactant, the detected ECL signal was amplified due to following multiple amplification strategies: (1) the ECL catalysis for Ru(bpy)(3)(2+) was performed by electro-inducing the DpAg particles to generate Ag(+) ion and controlled by the special potential. The catalyzer Ag(+) was produced near the electrode surface and reproduced by cyclic potential scan, which improved the catalytic efficiency. (2) The amount of the ECL signal probes linked to secondary antibodies were amplified by the adsorption of Pt nanoparticles and the multiple sites bridge linkage of biotin/SA. These new multiple signal amplification strategies made the proposed ECL immunosensor achieve ultrasensitive detection for model protein human IgG with a detection limit down to 3 pg mL(-1), which can be further extended to the detection of disease biomarkers.  相似文献   

9.
Zhang W  Zhao D  Zhang R  Ye Z  Wang G  Yuan J  Yang M 《The Analyst》2011,136(9):1867-1872
Electrochemiluminescence (ECL) detection technique using bipyridine-ruthenium(II) complexes as probes is a highly sensitive and widely used method for the detection of various biological and bioactive molecules. In this work, the spectral, electrochemical and ECL properties of a chemically modified bipyridine-ruthenium(II) complex, [Ru(bpy)(2)(dabpy)](2+) (bpy: 2,2'-bipyridine; dabpy: 4-(3,4-diaminophenoxy)-2,2'-bipyridine), were investigated and compared with those of its nitric oxide (NO)-reaction derivative [Ru(bpy)(2)(T-bpy)](2+) (T-bpy: 4-triazolephenoxy-2,2'-bipyridine) and [Ru(bpy)(3)](2+). It was found that the ECL intensity of [Ru(bpy)(2)(dabpy)](2+) could be selectively and sensitively enhanced by NO due to the formation of [Ru(bpy)(2)(T-bpy)](2+) in the presence of tri-n-propylamine. By using [Ru(bpy)(2)(dabpy)](2+) as a probe, a sensitive and selective ECL method with a wide linear range (0.55 to 220.0 μM) and a low detection limit (0.28 μM) was established for the detection of NO in aqueous solutions and living cells. The results demonstrated the utility and advantages of the new ECL probe for the detection of NO in complicated biological samples.  相似文献   

10.
The reaction occurring on electrooxidation of Ru(bpy)(3)(2+) (bpy = 2,2'-bipyridine) and tri-n-propylamine (TPrA) leads to the production of Ru(bpy)(3)(2+) and light emission. The accepted mechanism of this widely used reaction involves the reaction of Ru(bpy)(3)(3+) and a reduced species derived from the free radical of the TPrA. However, this mechanism does not account for many of the observed features of this reaction. A new route involving the intermediacy of TPrA cation radicals (TPrA(*+)) in the generation of Ru(bpy)(3)(2+) was established, based on results of scanning electrochemical microscopy (SECM)-electrogenerated chemiluminescence (ECL) experiments, as well as cyclic voltammetry simulations. A half-life of approximately 0.2 ms was estimated for TPrA(*+) in neutral aqueous solution. Direct evidence for TPrA(*+) in this medium was obtained via flow cell electron spin resonance (ESR) experiments at approximately 20 degrees C. The ESR spectra of the TPrA(*+) species consisted of a relatively intense and sharp septet with a splitting of approximately 20 G and a g value of 2.0038.  相似文献   

11.
This paper reports a novel detection method for DNA hybridization based on the electrochemiluminescence (ECL) of Ru(bpy)(3)(2+) with a DNA-binding intercalator as a reductant of Ru(bpy)(3)(3+). Some ECL-inducible intercalators have been screened in this study using electrochemical methods combined with a chemiluminescent technique. The double-stranded DNA intercalated by doxorubicin, daunorubicin, or 4',6-diamidino-2-phenylindole (DAPI) shows a good ECL with Ru(bpy)(3)(2+) at +1.19 V (versus Ag/AgCl), while the non-intercalated single-stranded DNA does not. In order to stabilize the self-assembled DNA molecules during ECL reaction, we constructed the ECL DNA biosensor separating the ECL working electrode with an immobilized DNA probe. A gold electrode array on a plastic plate was assembled with a thru-hole array where oligonucleotide probes were immobilized in the side wall of thru-hole array. The fabricated ECL DNA biosensor was used to detect several pathogens using ECL technique. A good specificity of single point mutations for hepatitis disease was obtained by using the DAPI-intercalated Ru(bpy)(3)(2+) ECL.  相似文献   

12.
A new capillary electrophoresis-electrochemiluminescence (ECL) detection system equipped with an electrically heated Ru(bpy)(3)(2+)/multi-wall-carbon-nanotube paste electrode (Ru(bpy)(3)(2+)/MWNTPE) was developed. Ru(bpy)(3)(2+) was immobilized in the electrode by directly mixing with the multi-wall-carbon-nanotube paste (MWNTP). This modified electrode could be electrically heated and temperature of the electrode (Te) could be accurately controlled. Tri-n-propylamine (TPrA) was used as coreactant to investigate CE-ECL signals under different conditions. Compared with the conventional electrode at room temperature, the heated electrode has been shown to provide some advantages, such as higher sensitivity, lower RSD, and decreasing width of the peak. Furthermore, wider range of capillary-to-electrode distance and larger-area electrode are a benefit to CE-ECL. In addition, this system has been applied to separation and detection of acephate and dimethoate. The results indicated that the present CE-ECL system coupled with heated modified-electrode could provide high sensitivity, wide linear range, satisfying linear relationship and excellent reproducibility.  相似文献   

13.
Chen L  Huang D  Zhang Y  Dong T  Zhou C  Ren S  Chi Y  Chen G 《The Analyst》2012,137(15):3514-3519
This work reports that ammonia (NH(3)) can be used as an efficient co-reactant for tris(2,2'-bipyridine)ruthenium(II) (Ru(bpy)(3)(2+)) electrochemiluminescence (ECL) in ionic liquids (ILs), on the basis of which a signal-on ECL sensor for directly detecting gaseous NH(3) has been developed. The NH(3) ECL sensor has a very high sensitivity, with a detection limit of 10 ppt NH(3) (at signal-to-noise ratio of 3) without any preconcentration. The high sensitivity is mainly due to the zero ECL background of Ru(bpy)(3)(2+) in the ILs, strong co-reactant ECL activity of NH(3), and high solubility of NH(3) in imidazolium-based ILs. Additionally, the ECL sensor shows an excellent selectivity against common interfering gases and a wide linear response range from 10 ppt to 10 ppm.  相似文献   

14.
The electrochemiluminescence (ECL) of magnetic microbeads modified with tris(2,2'-bipyridine)ruthenium(II) ([Ru(bpy)3]2+) was studied in the presence of tri-n-propylamine (TPA) to develop highly sensitive ECL detection system, where the employed microbead has a diameter of 4.5 microm. The ECL signal of the [Ru(bpy)3]2+ derivative-modified magnetic microbeads was found to be affected by the geometrical distribution of the magnetic microbeads on the electrode surface. The ECL peak intensity increased with increasing the number of the beads on the electrode surfaces up to 1.6 x 10(6) beads cm(-2), although above 1.6 x 10(6) beads cm(-2), it decreased. The ECL decrease arises from the physical prevention of the ECL from reaching the photomultiplier tube by the excessive beads. The observed peak ECL signal of the [Ru(bpy)3]2+ derivative-modified magnetic microbeads in the presence of NaN3, which serves as a preservative substance, mainly appeared at a potential of +0.90 V vs Ag/AgCl where [Ru(bpy)3]2+ is hardly oxidized, whereas the ECL signal in the absence of NaN3 appeared at a potential of +1.15 V. The presence of NaN3 on the electrode surface retards formation of an oxide layer on the electrode surfaces and promotes TPA oxidation. The ECL response at +0.90 V was mainly attributed to ECL reaction of excited-state [Ru(bpy)3]2+* formed by oxidation of [Ru(bpy)3]+ with TPA radical cation, where the [Ru(bpy)3]+ was generated by reduction of [Ru(bpy)3]2+ with TPA radical.  相似文献   

15.
Wu MS  Xu BY  Shi HW  Xu JJ  Chen HY 《Lab on a chip》2011,11(16):2720-2724
In this paper we report a transparent bipolar electrode based microfluidic chip-electrochemiluminescence (ECL) system for sensitive detection of folate receptors (FR) on cell membranes. This integrated system consists of a poly(dimethylsiloxane) (PDMS) layer containing a microchannel and a glass bottom sheet with indium tin oxide (ITO) strips as bipolar detectors. The ITO strips are fabricated using a PDMS micromold with carbon ink as a protective layer in place of traditional photoresist. The configuration of the bipolar electrode has great influence on the ECL intensity of Ru(bpy)(3)(2+)/tripropylamine(TPA) system. Further studies show that folic acid (FA) can strongly inhibit the ECL of the Ru(bpy)(3)(2+)/TPA system. Based on specific recognition between FA and FR on cell membrane, this microfluidic chip-ECL system is successfully applied for detecting the level of FR on human cervical tumor (HL-60) cells and MEF cells. It is found that the ECL intensity increases with the number of HL-60 cells in the range of 21 to 3.28 × 10(4) cells/mL. The average level of FR on HL-60 cells is calculated to be 8.05 ± 0.75 × 10(-18) mol/cell. While for MEF cells, it shows a much slower ECL increment than HL-60 cells due to the much lower FR level on MEF cells (5.30 ± 0.61 × 10(-19) mol/cell). Moreover, exocytosis of FA after FR mediated endocytosis was observed according to the change of the ECL signal with the incubation time of HL-60 cells in the FA- Ru(bpy)(3)(2+)/TPA system.  相似文献   

16.
Zhao P  Cao G  Zhou L  Liu Q  Guo M  Huang Y  Cai Q  Yao S 《The Analyst》2011,136(9):1952-1956
Tris(2,3-dibromopropyl) isocyanurate (TBC) is a heterocyclic hexabrominated flame retardant, which cannot be degraded even over a long time and may be a potential environmental pollutant. In this paper, TBC is for the first time as far as we know determined by silver nitrate-enhanced electrochemiluminescence (ECL) using a gold nanoparticles (AuNPs)-modified gold electrode. In our experiments, TBC was found to have the characteristics of increasing the ECL intensity of Ru(bpy)(3)(2+), and the ECL signal was proportional to the concentration of TBC. Based on this, we have successfully developed a novel, fast and sensitive method for the analysis of TBC. The main influencing factors including the volume ratio of acetonitrile and water, and the concentration of Ru(bpy)(3)(2+) were investigated in detail. Compared with using a bare gold electrode in MeCN without AgNO(3), the limit of detection is remarkably lowered by 20 times and the linear range is expanded by 5 times by using the AuNPs-modified gold electrode and AgNO(3). Under the optimal conditions, a limit of detection of 5.0 × 10(-8) M (S/N = 3) is achieved with a linear range of 1.0 × 10(-7) to 5.0 × 10(-5) M. The mechanism of the ECL enhancement of the system is also investigated.  相似文献   

17.
We report the synthesis and characterization of RuC7, a complex in which a heme is covalently attached to a [Ru(bpy)(3)](2+) complex through a -(CH(2))(7)- linker. Insertion of RuC7 into horse heart apomyoglobin gives RuC7Mb, a Ru(heme)-protein conjugate in which [Ru(bpy)(3)](2+) emission is highly quenched. The rate of photoinduced electron transfer (ET) from the resting (Ru(2+)/Fe(3+)) to the transient (Ru(3+)/Fe(2+)) state of RuC7Mb is >10(8) s(-1); the back ET rate (to regenerate Ru(2+)/Fe(3+)) is 1.4 x 10(7) s(-1). Irreversible oxidative quenching by [Co(NH(3))(5)Cl](2+) generates Ru(3+)/Fe(3+): the Ru(3+) complex then oxidizes the porphyrin to a cation radical (P*+); in a subsequent step, P*+ oxidizes both Fe(3+) (to give Fe(IV)=O) and an amino acid residue. The rate of intramolecular reduction of P*+ is 9.8 x 10(3) s(-1); the rate of ferryl formation is 2.9 x 10(3) s(-1). Strong EPR signals attributable to tyrosine and tryptophan radicals were recorded after RuC7MbM(3+) (M = Fe, Mn) was flash-quenched/frozen.  相似文献   

18.
Kang J  Yin XB  Yang X  Wang E 《Electrophoresis》2005,26(9):1732-1736
An electrochemiluminescence (ECL) inhibition method was developed as an indirect detection method for the determination of dopamine and epinephrine separated by capillary electrophoresis (CE). When the concentration of Ru(bpy)(3) (2+) was 50 muM diluted by 50 mM phosphate (pH 8.5) in the cell and 0.5 M tripropylamine (TPA) was added to the running buffer (10 mM phosphate, pH 9.0), an inhibition of ECL of the Ru(bpy)(3) (2+)/TPA system by the analytes was observed. Under the optimized conditions, the relative standard deviations of migration time and negative peak area were less than 1% and 3%, respectively, for 1 microM dopamine or 1 microM epinephrine (n = 10). Linear ranges of 0.1-10 microM for both analytes and the detection limits (signal-to-noise ratio S/N = 3) of 10 nM for dopamine and 30 nM for epinephrine were obtained.  相似文献   

19.
Wang J  Peng Z  Yang J  Wang X  Yang N 《Talanta》2008,75(3):817-823
Coupled capillary electrophoresis (CE) with end-column electrogenerated chemiluminescence (ECL) was adopted for the quantitative detection of clindamycin. Clindamycin enhanced ECL intensity of tris(2,2'-bypyridine)ruthenium(II) (Ru(bpy)(3)(2+)) as a coreactant. Under the optimized conditions, the ECL intensity was linear with the concentration of clindamycin over the range from 5.0 x 10(-7) to 1.0 x 10(-4)M with a detection limit of 1.4 x 10(-7)M. The proposed CE-ECL was successfully applied for the detection of clindamycin in pharmaceutical and clinic samples. The interaction of clindamycin with hemoglobin was also investigated. The binding constant of clindamycin with hemoglobin was estimated to be 3.6 x 10(3)M(-1).  相似文献   

20.
The spectroscopy, electrochemistry, and electrogenerated chemiluminescence (ECL) of [(q)(qH)Li]x (qH=8-hydroxyquinolinato) and [(Meq)(MeqH)Li]x (MeQH=2-methyl-8-hydroxyquinolinato) have been investigated. In both acetonitrile and aqueous solutions, [(q)(qH)Li]x and [(Meq)(MeqH)Li]x have absorption maxima at 320 and 309 nm, respectively. When excited at these wavelengths, the complexes emit around 500 nm (blue-green) in acetonitrile. Photoluminescence efficiencies (phiem) were 0.036 for [(q)(qH)Li]x and 0.012 for [(Meq)(MeqH)Li]x when compared to Ru(bpy)3(2+) (bpy=2,2'-bipyridine) with phiem=0.042. No photoluminescence was observed in aqueous media. The complexes show irreversible oxidative electrochemistry and quasi-reversible reductions in acetonitrile. ECL efficiencies (phiecl) were 0.097 for [(q)(qH)Li]x and 0.080 for [(Meq)(MeqH)Li]x when compared to Ru(bpy)(3)2+ (phiecl=1) in aqueous buffered solution and 0.035 for [(q)(qH)Li]x and 0.028 for [(Meq)(MeqH)Li]x in acetonitrile (0.05 M tri-n-propylamine (TPrA) as an oxidative-reductive ECL co-reactant). The ECL peaks at a potential corresponding to oxidation of both the TPrA and [(q)(qH)Li]x or [(Meq)(MeqH)Li]x. Also, qualitative studies using transmission filters suggest that both complexes emit ECL in approximately the same blue-green region as their photoluminescence, indicating that the same excited state is formed in both experiments.  相似文献   