首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
建立了高氯、高钠油田回注水中痕量无机阴、阳离子和有机酸的离子色谱分析方法。对高钠基质中痕量阳离子的测定,选用IonPac CS12A分析柱、H2SO4溶液梯度淋洗、电导检测器检测;对高氯基质中阴离子及有机酸的测定,选用对OH-具有高选择性的高容量的IonPac AS11-HC柱、KOH梯度淋洗、电导检测器检测。在优化的梯度淋洗条件下,高氯或高钠的存在不影响痕量阴离子或阳离子的测定。该方法具有良好的线性(r=0.9926~0.9990)和精密度(测定组分峰面积的相对标准偏差(n=7)在8.0%以下),回收率  相似文献   

2.
A single-column method for the simultaneous determination of common cations and transition metals in real samples is proposed in this paper. Eleven cations (copper, lithium, sodium, ammonium, potassium, cobalt, nickel, magnesium, calcium, strontium and zinc) were separated and analyzed by means of ion chromatography using an isocratic elution with 2.5 mM methane sulfonic acid and 0.8 mM oxalic acid as mobile phase, IonPac SCS1 (250 mm x 4 mm I.D.) as the separation column and non-suppressed conductor detection. Optimized analytical conditions were further validated in terms of accuracy, precision and total uncertainty and the results showed the reliability of the IC method. The relative standard deviations (RSDs) of the retention time and peak area were less than 0.04 and 1.30%, respectively. The coefficients of determination for cations ranged from 0.9988 to 1.000. The method developed was successfully applied to determination of cations in samples of beer and bottled mineral water. The spiked recoveries for the cations were 94-106%. The method was applied to beer and beverage without interferences.  相似文献   

3.
A simple, selective, and sensitive method for the simultaneous determination of anions (sulfate, nitrate, and chloride) and cations (sodium, ammonium, potassium, magnesium, and calcium) in acid rain waters was developed using ion-exclusion/ cation-exchange chromatography with conductimetric detection. A weakly acidic cation-exchange resin column (Tosho TSKgel OA-PAK-A) and a sulfosalicylic acid-methanol-water eluent was used. With a mobile phase comprising 1.25 mM sulfosalicylic acid in methanol-water (7.5:92.5) at 1.2 ml/min, simultaneous separation and detection of the above anions and cations was achieved in about 30 min. Linear calibration plots of peak area versus concentration were obtained over the concentration ranges 0-1.0 mM for anions (R=0.9991) and 0-0.5 mM for cations (R=0.9994). Detection limits calculated at S/N=3 ranged from 4.2 to 14.8 ppb for the anions and from 2.4 to 12.1 ppb for the cations. The reproducibility of retention times was 0.14-0.15% relative standard deviation (RSD) for anions and 0.18-0.31% for cations, and reproducibility of chromatographic peak areas was 1.22-1.75% RSD for anions and 1.81-2.10% for cations. The method was applied successfully to the simultaneous determination of anions and cations in aerosols transported from mainland China to central Japan, as determined by a meteorological satellite data analyzer.  相似文献   

4.
A method for the separation of acetate and formate anions by ion chromatography has been optimized under various measurement conditions (e.g. the composition of the mobile phase, and the flow rate of the eluent). For this purpose, two different analytical columns were examined: the IonPac AS14 (250 mm x 4 mm i.d.; designed mostly for the separation of inorganic anions) and the Allsep A-2 (150 mm x 4.6 mm i.d.; designed for the separation of low-molecular mass organic acids). However, nearly baseline separation of acetate and formate has been found on each column using the following conditions: (i) IonPac AS14 column and 2.0 mM Na2B4O7 solution as an eluent with a flow rate of 1.0 ml/min, or (ii) Allsep A-2 column and an eluent containing a mixture of 1.2 mM Na2CO3 plus 1.5 mM NaHCO3 with a flow rate of 1.3 ml/min. Additionally, the separation of fluoride from acetate and formate on both columns was studied. On the IonPac AS14 column it was possible to separate all three investigated anions. However, on the Allsep A-2 column, when the concentration of fluoride was comparable to, or higher than acetate, it was impossible to achieve good separation of these two anions, even using the optimized elution procedure. Therefore, the measurements of real samples were carried out with the use of IonPac AS14 column. The concentrations of acetate and formate have been determined in the air samples of the Cathedral of Cologne (Germany), after sampling the corresponding acids by passive diffusion tubes. Average concentrations of 122 and 9 microg/m(3) for acetic and formic acids were found, respectively, inside the Cathedral and in a depot with medieval stained glass panels.  相似文献   

5.
While alkali and alkaline earth cations are commonly determined by using spectrometric techniques such as atomic absorption spectrometry or inductively coupled plasma, ammonium cation in the same sample must be measured separately by a wet chemical technique such as colorimetry, titrimetry, or ammonia-selective electrode. In a single 25-min run ion chromatography can determine all of the important inorganic cations including lithium, sodium, ammonium, potassium, magnesium and calcium. In this paper, we describe the use of ion chromatography with a new high-capacity cation-exchange column (the IonPac CS16), an electrolytically-generated methanesulfonic acid eluent and suppressed conductivity detection to determine dissolved alkali and alkaline earth cations and ammonium in drinking water wastewater and aqueous soil extracts. The IonPac CS16 is a high-capacity cation-exchange column that incorporates recent advances in polymer chemistry to enable trace-level determinations of cations even in high-ionic-strength matrices. We discuss the linear range, method detection limits, and analyte recoveries obtained with this column, and evaluate the effect of potential interferences on method performance during the analysis of typical environmental samples.  相似文献   

6.
A new approach for simultaneous separation of small inorganic and organic anions and metal cations by capillary electrophoresis is demonstrated. Metal cations in the sample are transformed into their chelates with EDTA and are separated together with the anions using an anionic separation mode. Simultaneous separation of 19 common anions and cations was achieved in about 6 min with the electrolyte containing 5 mM K2CrO4, 3 mM boric acid, 35 microM cetyltrimethylammonium bromide and 12 microM EDTA at pH 8. Limits of detection (s/n = 3) were in the range from 4 ppb for Cl- up to 1250 ppb for Cu-EDTA and RSDs of peak areas ranged from 1.4% for Cl- up to 8.5% for Mn-EDTA chelate. The practical applicability of the method was demonstrated on the analysis of anions and cations in various water samples.  相似文献   

7.
An ion chromatography method was developed to determine trace anionic contamination in matrices that have a high concentration of nitrate ion. Contaminant anions of interest were separated on an IonPac AS15 high-capacity anion-exchange column and detected by suppressed conductivity detection. An EG40 eluent generator was used to prepare high-purity and carbonate-free potassium hydroxide. Using the EG40, performance at trace levels was enhanced because background conductivity decreased and retention time reproducibility improved. Trace anionic contamination from the mobile phase was minimized when using the eluent generator compared to using conventionally prepared sodium hydroxide eluents. The signal-to-noise ratio was also improved with the use of a temperature controlled conductivity cell and chromatography hardware in the microbore (2-mm) format. The eluent concentration was optimized to separate the contaminant anions from the excess of the nitrate matrix ions. The procedure was demonstrated for a solution of reagent-grade sodium nitrate and high-purity 0.7% nitric acid. Method detection limits for chloride, sulfate and phosphate of 150 μg/l and lower were achieved.  相似文献   

8.
Although anions are usually determined by suppressed ion chromatography (IC), carbonate and bicarbonate ions can not be determined, because a mixed solution of sodium carbonate and sodium hydrogencarbonate is used as the eluent. This paper describes an IC method for the determination of carbonate ion and common anions using an IonPac AG17/AS17 column, an EG 40 eluent generator and a conductivity detector. The proposed IC method could determine carbonate ion and anions within 6 min. The relative standard deviations (n = 5) for chloride (0.4 mg L(-1)), nitrite (0.8 mg L(-1)), carbonate (100 mg L(-1)), nitrate (1.0 mg L(-1)) and sulfate (2.0 mg L(-1)) ions were 5.1%, 1.1%, 4.2%, 5.1% and 1.1%, respectively. In addition, the absorbing solution of carbon dioxide was examined, and 2-amino-2-methyl-1-propanol was found to be a good absorbing solution. The proposed IC method was applied to the determination of carbon dioxide and acid components in flue gas and automobile exhaust gas.  相似文献   

9.
Isildak I  Asan A 《Talanta》1999,48(4):967-978
The overall efficiency of ion chromatographic procedures allows the possibility of routine separation and detection of common inorganic and organic anions and cations at low levels in a simultaneous system. A simple and rapid independent separation, and sensitive simultaneous detection of monovalent common anions and cations were achieved using 2 mM copper sulfate, (at pH: 5.40), as eluent with low cell-volume potentiometric detectors. This was established using all-solid state contact, tubular, PVC-matrix membrane anion and cation-selective electrodes in series as detectors with mixed-bed ion-exchange column in ion chromatography. The developed method is reproducible and highly selective to monovalent anions and cations, and takes less than 8 min. Under all operation conditions, the detection limits of the developed method, for potassium, rubidium, cesium, thallium(I), nitrite, nitrate, benzoate and bromide, were of the order of tens of ppb, for sodium, ammonium, chloroacetate, cyanate and chloride ions, values were of the order of hundreds of ppb for an injected volume of 20 mul. The method was flexible since most of anions do not interfere the detection of cations and most of cations do not affect the detection of anions, so that the method can be applied to many sample types e.g. environmental. The application of the method for river, sea and tap water samples were illustrated.  相似文献   

10.
金菊花  叶明立 《色谱》2016,34(10):960-963
建立了头孢克肟、月桂酰吲达帕胺、布地奈德等难溶性药物中氯离子和三氟乙酸根的阀切换-离子色谱检测方法。分离柱为IonPac AS23柱,通过考察阴离子保留情况,选择3.5 mmol/L碳酸钠+1.0 mmol/L碳酸氢钠作淋洗液,对难溶性药物中氯离子和三氟乙酸根进行了分析。在上述条件下,氯离子和三氟乙酸根能很好地分离,并在质量浓度为0.10~10.00 mg/L时与对应色谱峰面积之间的线性关系良好,检出限分别为0.006 mg/L和0.06 mg/L,回收率为90%~94%。该方法简便、快速、准确,可用于实际样品的测定。  相似文献   

11.
Influence of acidic eluent on retention behaviors of common anions and cations by ion-exclusion/cation-exchange chromatography (ion-exclusion/CEC) were investigated on a weakly acidic cation-exchange resin in the H(+)-form with conductivity. Sensitivities of analyte ions, especially weak acid anions (F(-) and HCOO(-)), were affected with degree of background conductivity level with pK(a1) (first dissociation constant) of acid in eluent. The retention behaviors of anions and cations were related to that of elution dip induced after eluting acid to separation column and injecting analyte sample. These results were largely dependent on the natures of acid as eluent. Through this study, succinic acid as the eluent was suitable for simultaneous separation of strong acid anions (SO(4)(2-), Cl(-), NO(3)(-) and I(-)), weak acid anions (F(-), HCOO(-) and CH(3)COO(-)), and cations (Na(+), K(+), NH(4)(+), Mg(2+) and Ca(2+)). The separation was achieved in 20 min under the optimum eluent condition, 20 mM succinic acid/2 mM 18-crown-6. Detection limits at S/N=3 ranged from 0.10 to 0.51 microM for strong acid anions, 0.20 to 5.04 microM for weak acid anions and 0.75 to 1.72 microM for cations. The relative standard deviations of peak areas in the repeated chromatographic runs (n=10) were in the range of 1.1-2.9% for anions and 1.8-4.5% for cations. This method was successfully applied to hot spring water containing strong acid anions, weak acid anions and cations, with satisfactory results.  相似文献   

12.
The preparation and evaluation of zirconium-adsorbing silica gel (Zr-Silica) as an ion-exchange stationary phase in ion chromatography for inorganic anions and cations was carried out. The Zr-Silica was prepared by the reaction of silanol groups on the surface of the silica gel with zirconium butoxide (Zr(OCH2CH2CH2CH3)4) in ethanol. The ion-exchange characteristics of the Zr-Silica were evaluated using 10 mM tartaric acid at pH 2.5 as eluent. The Zr-Silica was found to act as a cation-exchanger under the eluent conditions. The retention behavior of alkali and alkaline earth metal cations was then investigated. The Zr-Silica column was proved to be suitable for the simultaneous separation of alkali metal cations and ammonium ion. Excellent separation of the cations on a 15 cm Zr-Silica column was achieved in 25 min using 10 mM tartaric acid as eluent.  相似文献   

13.
Yokoyama Y  Sawaguchi N  Sato H 《The Analyst》2001,126(7):989-994
A successive non-suppressed ion chromatography (IC) system for the determination of common cations (Na+, K+, Mg2+, Ca2+) and anions (Cl-, Br-, NO3-, SO4(2-)) was developed, using two separation columns and a single eluent. 5-Sulfoisophthalic acid eluent was very suitable for such separations with a commercially available cation-exchange column for the mono- and di-valent cations and with an ODS column coated with cetyltrimethylammonium for the anions. Both cations and anions were detected with conductimetrically high sensitivity without any suppressor. After injecting an aliquot of sample solution, the solvent front from the cation-exchange column, including most of the anionic species, was firstly accumulated into the additional 2 ml accumulation loop for 60 s, while the cation IC was performed. Subsequently, the accumulated fraction was introduced into the anion-exchange column and chromatographed. Relative standard deviations (RSDs) of retention times and conductimetric area responses for common cations were within 6% and within 4%, respectively. The linear relationships between molar concentration and detector response ranged from 0.01 to 1.00 mM with r2 of 0.9994 for Na+, 0.9992 for K+, 0.9993 for Mg2+, and 0.9988 for Ca2+. The successive anion IC through the accumulating process was also quantitative, with 95% recovery or over for each analyte. The linear ranges were between 0.01 and 1.00 mM with r2 of 0.9996 for Cl-, 0.9997 for Br-, 0.9993 for NO3-, and 0.9984 for SO4(2-). The method was applied to the determination of common cations and anions in several mineral waters and a hot spring water.  相似文献   

14.
Muhammad Amin 《Talanta》2007,71(4):1470-1475
A convenient ion chromatography method has been proposed for the routine and simple determination of anions (Cl, SO42− and NO3) and/or cations (Na+, NH4+, K+, Mg2+ and Ca2+) using a single pump, a single eluent and a single detector. The present system used cation-exchange and anion-exchange columns connected in series via two 6-port switching valves or a single 10-port valve. The connection order of the ion-exchange columns could be varied by switching the valve(s). The present system therefore allowed the separation of either cations or anions in a single chromatographic run. While one ion-exchange column is being operated, the other ion-exchange column is being conditioned, i.e., the columns are always ready for analysis at any time. When 2.4 mM 5-sulfosalicylic acid was used as the eluent, the three anions and the five cations could be separated on the anion-exchange column and cation-exchange column, respectively. In order to obtain the separations of the target ions, the injection valve was placed between the two columns. Complete separations of the above anions or cations were demonstrated within 10 min each. The detection limits at S/N = 3 were 19-50 ppb (μg/l) for cations and 10-14 ppb for anions. The relative standard deviations of the analyte ions were less than 1.1, 2.9 and 2.8% for retention time, peak area and peak height, respectively. This proposed technique was applied to the determination of common anions and cations in river water samples.  相似文献   

15.
An ion chromatography (IC) method has been proposed for the determination of seven common inorganic anions (F(-), H(2)PO(4)(-), NO(2)(-), Cl(-), Br(-), NO(3)(-), and SO(4)(2-)) and/or five common inorganic cations (Na(+), NH(4)(+), K(+), Mg(2+), and Ca(2+)) using a single pump, a single eluent and a single detector. The present system used cation-exchange and anion-exchange columns connected in series via a single 10-port switching valve. The 10-port valve was switched for the separation of either cations or anions in a single chromatographic run. When 1.0mM trimellitic acid (pH 2.94) was used as the eluent, the seven anions and the five cations could be separated on the anion-exchange column and the cation-exchange column, respectively. The elution order was found to be F(-)相似文献   

16.
为实现简单基质样品中常规阴离子的快速分析,选用Dionex IonPac AS22-fast(4mm×150mm)离子交换色谱柱,通过优化流速、淋洗液浓度等色谱条件,使F-、Cl-、NO3-、NO2-、Br-、PO43-、SO42-7种常规阴离子在3.5min内分离完全,实现简单基质样品中常规阴离子的快速测定。  相似文献   

17.
离子色谱测定口腔含漱剂中的多种成分   总被引:1,自引:0,他引:1  
章燕珍  焦霞  刘丽  周琰春  朱岩 《分析化学》2007,35(7):1032-1034
建立了离子色谱法对口腔含漱剂中抗龋剂如氟离子、单氟磷酸根、甘油磷酸根、防腐剂山梨酸、甜味剂糖精以及氯离子、硫酸根、磷酸根等同时测定的方法。采用AS11色谱分析柱和KOH梯度淋洗,抑制电导检测。被测物质的保留时间和峰面积重现性分别小于1.51%和6.02%;被测物的线性相关系数为0.9990~0.9999;加标回收率为89.4%~102.5%。本方法可用于商品化含漱剂和牙棒液体多种组分的同时测定。  相似文献   

18.
建立了一种在线基体消除的方法,采用离子色谱法测定了墨水染料中的氯和硫酸盐。样品经溶解、稀释后直接进样,在纯水的输送下依次经过DIONEX OnGuard Ⅱ P和IonPac NG1柱,在线实现了墨水样品中染料和疏水性干扰基体的去除,死时间流出的待测阴离子浓缩于阴离子交换柱IonPac AG11-HC。浓缩柱经阀切换进入离子色谱系统,以4.5 mmol/L Na2CO3-0.8 mmol/L NaHCO3作为淋洗液,流速1.2 mL/min,待测离子经IonPac AS23(4 mm×250 mm)分析柱分离,采用DIONEX DS6电导检测器检测,外标法定量。Cl-和SO2-4的线性范围分别为0.05~5.0、0.1~10.0 mg/L,相关系数分别为0.999 8和 0.999 7,加标回收率为94%~103%,相对标准偏差(n=11)小于1.0%,检出限(S/N=3)分别为0.02、0.05 mg/L。该方法用于墨水染料中氯和硫酸盐的测定,结果满意。  相似文献   

19.
固相萃取-离子色谱法测定饮用水中的痕量卤代乙酸   总被引:3,自引:0,他引:3  
孙迎雪  黄建军  顾平 《色谱》2006,24(3):298-301
建立了固相萃取-离子色谱(SPE-IC)测定饮用水中痕量卤代乙酸(HAAs)(包括一氯乙酸、二氯乙酸、三氯乙酸、一溴乙酸和二溴乙酸)的方法。固相萃取采用LiChrolut EN SPE柱来进行痕量待测物的预浓缩(25倍)和基体杂质的消除,用NaOH(10 mmol/L)洗脱;色谱分离采用亲水性、高容量、氢氧化物选择型阴离子交换柱Dionex IonPac AS16(250 mm×4 mm i.d.),以NaOH为流动相进行浓度梯度淋洗,淋洗速度为0.8 mL/min,电导检测,进样量为500 μL。结果表明,用SPE-IC法测定HAAs,一溴乙酸的检测限为12.5 μg/L,其余4种HAAs的检测限为0.38~1.69 μg/L。该法可实现对饮用水中痕量卤代乙酸的测定。  相似文献   

20.
浓碱中痕量阴离子的测定在化学化工和半导体工业中非常重要,而常规测定浓碱中阴离子的方法是采用分光光度法和浊度法。采用这些方法只能逐一对样品中的阴离子进行分析测定[1],不仅烦琐费时,而且测定结果往往不准确。离子色谱对于测定常规阴离子具有很高的灵敏度和较低的检出限,  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号