首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The paper describes the determination of the molybdenum content in white wines based on its catalytical action on the kalium iodide oxidation by hydrogen peroxide in acid medium.

The optimum reaction conditions (the catalyst, KI and H2O2 concentrations, the pH value, the order of the reagent additions, the temperature) have been found by studying the effect of the reaction variables.

The influence of some metallic ions (Ca2+, Mg2+, Zn2+, Cd2+, Fe2+ and Fe3+) and complexing anions (F, C2O2−4, EDTA4−) on the catalyzed reaction rate was elucidated.

The molybdenum concentration was estimated by the tangent, fixed-time and fixed-absorbance method. The obtained average values for molybdenum content in white wines are within the 1.77×10−7–1.83×10−7 mol l−1 range.  相似文献   


2.
Inam R  Somer G 《Talanta》1998,46(6):1347-1355
The polarographic reduction of lead in the presence of selenite gives rise to an additional peak corresponding to the reduction of lead (Pb) on adsorbed selenium (Se) on mercury at −0.33 V. The selenium and lead content can be determined using this peak by the addition of a known amount of one of these ions first and then the second ion. The linear domain range of lead is 5.0×10−7–2.0×10−5 M and for selenium 5.0×10−7–1.0×10−5 M. Using this method 4.90×10−7 M Se(IV) and 1.47×10−6 M Pb(II) in a synthetic sample could be determined with a relative error of +2.0% and 1.8%, respectively (n=4). A recovery test after acid digestion for a synthetic sample was 97% for selenium and 96.5% for lead. The method was applied to 1 ml of digested blood, and 328±23 μg l−1 Se(IV) and 850±62 μg l−1 Pb(II) could be determined with a 90% (n=5) confidence interval.  相似文献   

3.
Molybdenum(VI) is determined by anodic stripping voltammetry using a carbon paste electrode modified in situ with cetyltrimethylammonium bromide (CTAB). The preconcentration of molybdenum is performed by adsorption and reduction of ion-pairs of cetyltrimethylammonium and molybdenum(VI) oxalate at a potential of −0.4 V vs. the saturated calomel electrode (SCE). The supporting electrolyte contains 0.01 M oxalic acid and 0.075 mM CTAB. Differential pulse anodic stripping voltammetry exploiting the reoxidation signal is used for the determination of trace levels of molybdenum(VI). Linearity between current and concentration exists for a range of 0.5–500 μg 1−1 Mo with proper preconcentration times; the limit of detection (calculated as 3σ) is 0.04 μg 1−1 with an accumulation period of 10 min.  相似文献   

4.
A method for low-molecular-mass anion screening is described using a buffer composed of 5-sulfosalicylate (SS) as a visualizing ion, hexadimethrine bromide as an electroosmotic flow modifier and Tris as a pH buffer component, at pH 8.6. All ions with effective mobility higher than 2610−9 m2 s−1 V−1 can be separated within 7.5 min under −30 kV. By using the moderately mobile SS (5410−9 m2 s−1 V−1), not only the sensitivity of the detection is improved due to its high UV absorptivity, but also a smaller overall overloading effect is achieved. Meanwhile, the resolution of the high mobility ions, which is normally critical, remains almost the same as compared to a chromate buffer. With an electrokinetic injection, the limit of detection (LOD) of the common ions is 2–13 nM and the detection range is linear up to 0.5–3 μM. With a hydrostatic injection the LOD is 0.15–1 μM and the detection range is linear up to 25–200 μM. The identification of ions is performed by comparing the mobility of the ions with that of standards, taking the apparent and effective mobility of HCO3, which is normally present in the sample solution, as a reference.  相似文献   

5.
A number of experimental parameters have been optimized for the separation of 26 metal ions, including alkali, alkaline earth, transition and lanthanide metal ions. Experimental parameters that were evaluated included nature of indirect-detection reagent, pH of electrolyte, concentration of complexing agent and nature of the surface of the capillary; unbonded and C1 and C18 bonded phases were studied. In addition the effect of internal diameter on linearity and signal-to-noise ratio was examined, and separation efficiency was determined for a variety of experimental conditions. Detection limits (signal-to-noise RATIO = 3) were ca. 1 μg/ml for the lanthanides, ca. 0.6 μg/ml for transition and alkaline earth ions and ca. 0.1–0.8 μg/ml for alkali metal ions. The average relative standard deviations of were 3.7, 5.1 and 2.5% on unbonded, C1 and C18 capillaries, respectively. Whereas conventional regression analysis suggested that the calibration curves were linear over the range of 1·10−5 to 4·10−4 mol/l, sensitivity plots showed that the results were actually linear to within 6% only over the range of 2.5·10−5 to 4·10−4 mol/l.  相似文献   

6.
The anodization of mercury microelectrodes was investigated in synthetic samples containing several strong and weak electrolytes at different concentrations. In particular, the effects on mercury anodization due to the presence of NaOH, HClO4, NaCl, NaI, NaF, Na2SO4, NaHCO3, Na2CO3, tartaric and citric acids, were studied in solutions containing either each species or mixtures of them, and without addition of supporting electrolyte. Some of the electrode processes studied led to linear calibration plots e.g. 1 × 10−5 − 1 × 10−4M Cl, 1 × 10−6 − 1 × 10−5M I, 5 × 10−4 − 3 × 10−3M SO42−, 5 × 10−4 − 2 × 10−2M HCO3, with typical correlation coefficients of 0.998–0.999. The anodization of mercury microelectrodes was also investigated directly in wine, rain, tap and mineral water, without pretreatment and without addition of supporting electrolyte. In the real samples only the ions Cl and HCO3 could be quantified, and the values found were in agreement, within 3–5%, with the reference values obtained by using Italian standard methods for food.  相似文献   

7.
Hassan SS  Ali MM  Attawiya AM 《Talanta》2001,54(6):1153-1161
Two novel uranyl PVC matrix membrane sensors responsive to uranyl ion are described. The first sensor incorporates tris(2-ethylhexyl)phosphate (TEHP) as both electroactive material and plasticizer and sodium tetraphenylborate (NaTPB) as an ion discriminator. The sensor displays a rapid and linear response for UO22+ ions over the concentration range 1×10−1–2×10−5 mol l−1 UO22+ with a cationic slope of 25.0±0.2 mV decade−1. The working pH range is 2.8–3.6 and the life span is 4 weeks. The second sensor contains O-(1,2-dihydro-2-oxo-1-pyridyl)-N,N,N′,N′-bis(tetra-methylene)uronium hexafluorophosphate (TPTU) as a sensing material, sodium tetraphenylborate as an ion discriminator and dioctyl phenylphosphonate (DOPP) as a plasticizer. Linear and stable response for 1×10−1–5×10−5 mol l−1 UO22+ with near-Nernstian slope of 27.5±0.2 mV decade−1 are obtained. The working pH range is 2.5–3.5 and the life span of the sensor is 6 weeks. Interference from many inorganic cations is negligible for both sensors. However, interference caused by some ions (e.g. Th4+, Cu2+, Fe3+) is eliminated by a prior ion exchange or solvent extraction step. Direct potentiometric determination of as little as 5 μg ml−1 uranium in aqueous solutions shows an average recovery of 97.2±1.3%. Application for the determination of uranium at levels of 0.01–1 wt.% in naturally occurring and certified ores gives results with good correlation with data obtained by X-ray fluorescence.  相似文献   

8.
Mealor D  Townshend A 《Talanta》1968,15(12):1477-1480
Methods are described for the determination of cyanide (10−8–10−5M and sulphide (10−7–10−5 M) based on the de-inhibitory effect of these ions on invertase inhibited by mercury(II) or by silver. Iodine (0.1–3 μg) may be determined by its inhibition of invertase.  相似文献   

9.
Tomiyasu T  Teshima N  Nakano S  Kawashima T 《Talanta》1998,47(5):434-1098
A new kinetic-catalytic method by the initial rate procedure for the determination of nanogram level of iron(III) is developed, which is based on its catalytic effect on the oxidative coupling of 3-methyl-2-benzothiazolinone hydrazone (MBTH) with N,N-dimethylaniline (DMA) to form an indamine dye (λmax=590 nm) in the presence of hydrogen peroxide. Iron(II) is also determined, being oxidized to iron(III) by hydrogen peroxide. Calibration graphs obtained by the initial rate method are linear in the range 1–1000 ng ml−1 Fe and as low as 10−8 M Fe(II, III) can easily be determined. The relative standard deviations are 6.6, 2.5 and 1.5% for ten determinations of 1, 20 and 60 ng ml−1 of Fe(III), respectively. The method is applicable to the determination of iron in natural waters without preconcentration and separation.  相似文献   

10.
Mealor D  Townshend A 《Talanta》1968,15(12):1371-1376
Thiourea has been found to enhance the inhibition of invertase by silver ions. The effect is applied to the determination of 1–5 × 10−7 M silver and of 10−7–10−8 M thiourea. A mechanism is suggested for the enhancement.  相似文献   

11.
A catalytic flow-injection (FI) method was developed for the determination of 10−9 mol l−1 levels of vanadium(IV, V). The method is based on the catalytic effect of vanadium(V) on oxidation of N-(3-sulfopropyl)-3,3′,5,5′-tetramethylbenzidine (TMBZ·PS) using bromate as oxidant to form a yellow dye (λmax=460 nm). The use of 5-sulfosalicylic acid (SSA) as an activator enhanced the sensitivity of the method. The calibration graphs with a working range 0.05–8.0 ng ml−1 were obtained for vanadium(V). Vanadium(IV) was also determined, being oxidized by bromate. The detection limit (signal/noise, S/N=3) was 0.01 ng ml−1 (ca. 2×10−10 mol l−1) vanadium. The relative standard deviations (R.S.D.) for 15 determinations of 0.5 ng ml−1 vanadium, and for ten determinations of 0.1 and 1.0 ng ml−1 vanadium were 0.41, 2.6 and 0.25%, respectively, with a sampling rate of 15 samples h−1. The proposed method was successfully applied to the determination of vanadium in natural waters.  相似文献   

12.
van Staden JF  Stefan RI 《Talanta》1999,49(5):1472-1022
An on-line automated system for the simultaneous flow injection determination of calcium and fluoride in natural and borehole water with conventional calcium-selective and fluoride-selective membrane electrodes as sensors in series is described. Samples (30 μl) are injected into a TISAB II (pH=5.50) carrier solution as an ionic strength adjustment buffer. The sample-buffer zone formed is first channeled to a fluoride-selective membrane electrode and then via the calcium-selective membrane electrode to the reference electrodes. The system is suitable for the simultaneous on-site monitoring of calcium (linear range 10−5–10−2 mol l−1 detection limit 1.94×10−6 mol l−1 recovery 99.22%, RSD<0.5%) and fluoride (linear range 10−5–10−2 mol l−1 detection limit 4.83×10−6 mol l−1 recovery 98.63%, RSD=0.3%) at a sampling rate of 60 samples h−1.  相似文献   

13.
Chen GN  Zhang L  Lin RE  Yang ZC  Duan JP  Chen HQ  Hibbert DB 《Talanta》2000,50(6):1275-1281
The electrogenerated chemiluminescent (ECL) behavior of hemin at a platinum electrode in the alkaline solution has been investigated in detail. Under the optimum conditions the linear response range of hemin is 1.0×10−5–1.0×10−8 g ml−1, the detection limit was 1.0×10−8 g ml−1, and the relative standard derivation for 1×10−7 g ml−1 hemin was 2.8%. It has been also found that hemin would catalyze the ECL of lucigenin at a platinum electrode in a neutral solution in the presence of hydrogen peroxide, the catalytic ECL intensity was linear with the concentration of hemin in the range of 1.0×10−14–1.0×10−10 g ml−1. IgG labeled with hemin was used to examine the ECL catalytic activity of hemin after conjugating to protein, and the results showed that hemin retained ECL catalytic activity when conjugated to protein.  相似文献   

14.
A new spectrophotometric flow-injection (FI) method is proposed for the determination of glucose based on the redox reaction of hydroquinone with iron(III). When a glucose solution containing quinone is passed through the immobilized glucose oxidase column introduced in FI system, quinone is reduced to hydroquinone by glucose. In the presence of 1,10-phenanthroline (phen), iron(III) is then quantitatively reduced by hydroquinone to iron(II) followed by the formation of iron(II)-phen complex (λmax=510 nm). An FI peak observed at 510 nm corresponds to the concentration of glucose. The wide dynamic range for glucose was obtained in the range of 1×10−6–1×10−3 mol l−1 at a sampling rate of 24 h−1 and the detection limit (S/N=3) was 5×10−7 mol l−1. Relative standard deviations were 0.78, 0.44 and 0.23% (n=5) for 5×10−6, 5×10−5 and 5×10−4 mol l−1 of glucose, respectively. The proposed method was successfully applied to the determination of glucose in control blood sera, human blood plasma and wine.  相似文献   

15.
De Marco R  Phan C 《Talanta》2003,60(6):1215-1221
The direct flow injection potentiometric (FIP) analysis of phosphate in hydroponic nutrient solution has been carried out using a cobalt-wire ion-selective electrode (ISE). Synthetic hydroponic nutrient solution, commercial hydroponic nutrient solution and working hydroponic farm nutrient solution were analysed for phosphate using the FIP technique. It is shown that FIP results compare favourably to standard methods of analysis such as spectrophotometry and indirect photometric ion-pair chromatography. Reproducible FIP response curves with a slope of −(47.57±0.03) mV per decade and intercept of −(169.7±0.1) mV were obtained for four separate calibrations in the concentration range 5.0×10−4–1.0×10−2 M H2PO4. Anion corrections for interferences by Cl, NO3 and SO42− were applied to all samples using the selectivity coefficients determined independently using a fixed interference method. Nevertheless, it was found that anion corrections were not necessary, as the deviations fell within the bounds of experimental error for the cobalt-wire ISE technique (i.e.±2–5% R.S.D.). The proposed FIP method enables the direct determination of phosphate in hydroponic nutrient solutions.  相似文献   

16.
The cathodic adsorptive electrochemical behavior of guanine in the presence of some metal ions at the static mercury drop electrode was investigated. A 1.0×10−3 mol l−1 NaOH or a 2.0×10−2 mol l−1 Hepes buffer at pH 8.0 solutions were used as supporting electrolytes. The reduction peak potential for guanine was found to be around −0.15 V, which is very close to the mercury reduction wave. A new peak appears at −0.60 V in the presence of copper or at −1.05 V in the presence of zinc. A square wave voltammetric procedure for electroanalytical determination of guanine in 2.0×10−2 mol l−1 Hepes buffer at pH 8.0 containing 1.6×10−5 mol l−1of copper ions, was developed. An accumulation potential of −0.15 V during 270 s for the prior adsorption of guanine at the electrode surface was used. The response of the system was found to be linear in the range of guanine concentration from 6.62×10−8 to 1.32×10−7 mol l−1 and the detection limit was 7.0×10−9 mol l−1. The influence of DNA bases such as adenine, cytosine and thymine was also examined. Cyclic voltammetry was used to characterize the interfacial and redox mechanism.  相似文献   

17.
Cha KW  Park CI  Park SH 《Talanta》2000,52(6):689-989
Uranium(VI) complexed with aluminon (3-[bis(3-carboxy-4-hydroxy-phenyl)methylene]-6-oxo-1,4-cyclohexadiene-1-carboxylic acid triammonium salt) was determined by adsorptive cathodic stripping voltammetry (ACSV) using a hanging mercury drop electrode. Trace uranium(VI) and zinc(II) can be simultaneously determined in a single scan in the presence of aluminon and urea. Optimal conditions were found to be: accumulation time; 180–200 s, accumulation potential; 50 mV versus Ag/AgCl, scan rate; 40 mV s−1, supporting electrolyte; 0.1 M sodium acetate buffer at pH 6.5–7.0, and concentration of aluminon; 1×10−6 M. The linear range of uranium(VI) and zinc(II) were observed over the concentration range 2–33 and 30–120 ng ml−1, respectively. The detection limit (S/N=3) are 0.2 ng ml−1 (uranium) and 30 ng ml−1 (zinc). A good reproducibility shows RSDs of 2.5–4.0% (n=10). The procedure offers high selectivity, with the presence of urea masking some metal ions.  相似文献   

18.
Methanol diffusion in two polymer electrolyte membranes, Nafion 117 and BPSH 40 (a 40% disulfonated wholly aromatic polyarylene ether sulfone), was measured using a modified pulsed field gradient NMR method. This method allowed for the diffusion coefficient of methanol within the membrane to be determined while immersed in a methanol solution of known concentration. A second set of gradient pulses suppressed the signal from the solvent in solution, thus allowing the methanol within the membrane to be monitored unambiguously. Over a methanol concentration range of 0.5–8 M, methanol diffusion coefficients in Nafion 117 were found to increase from 2.9 × 10−6 to 4.0 × 10−6 cm2 s−1. For BPSH 40, the diffusion coefficient dropped significantly over the same concentration range, from 7.7 × 10−6 to 2.5 × 10−6cm2 s−1. The difference in diffusion behavior is largely related to the amount of solvent sorbed by the membranes. Increasing the methanol concentration results in an increase in solvent uptake for Nafion 117, while BPSH 40 actually excludes the solvent at higher concentrations. In contrast, diffusion of methanol measured via permeability measurements (assuming a partition coefficient of 1) was lower (1.3 × 10−6 and 6.4 × 10−7 cm2 s−1 for Nafion 117 and BPSH 40 respectively) and showed no concentration dependence. The differences observed between the two techniques are related to the length scale over which diffusion is monitored and the partition coefficient, or solubility, of methanol in the membranes as a function of concentration. For the permeability measurements, this length is equal to the thickness of the membrane (178 and 132 μm for Nafion 117 and BPSH 40 respectively) whereas the NMR method observes diffusion over a length of approximately 4–8 μm. Regardless of the measurement technique, BPSH 40 is a greater barrier to methanol permeability at high methanol concentrations.  相似文献   

19.
We report on the degradation of gas phase vitamin C (ascorbic acid, AA) induced by low-energy electrons. In the energy range of (0–12) eV, different negatively charged fragments, attributed to the dehydro-ascorbic acid anion ((AA–H)), OH, O and H, are observed. The yield functions indicate that these ions are formed via dissociative electron attachment, DEA. While the formation of (AA–H) is exclusively observed at sub-excitation energies (<1.5 eV), the other fragments arise from resonance features at higher energies. Possible implications of these observations for radiation damage and food treatment by high energy radiation are considered.  相似文献   

20.
Cha KW  Park KW 《Talanta》1998,46(6):1567-1571
The spectrofluorimetric determination of Fe3+ using salicylic acid as an emission reagent has been investigated by measuring the decrease of fluorescence intensity of salicylic acid due to the complexation of Fe3+–salicylic acid. An emission peak of salicylic acid, which is decreased linearly by addition of Fe3+, occurs at 409 nm in aqueous solution with excitation at 299 nm. The determination of the ferric ion is in the range 1×10−6–10×10−6 M Fe3+ (0.0558–0.558 μg/ml) and the detection limit is 5×10−8 M. The quenching effect of Fe3+ on the fluorescence intensity of salicylic acid may be considered on the basis of complexation between salicylic acid and Fe3+. The effects of foreign ions were investigated.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏