首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 843 毫秒
1.
Ad-/desorption-kinetic measurements were performed for carbon dioxide on a mono-disperse crystal sample of NaX-type zeolite (mean crystal diameter: 2R (100 ± 6) m) by a constant-volume–variable-pressure method in a differential concentration mode over ranges of temperature, (193–293) K, and pressure, (20–26,700) Pa. They revealed a complex sorption process in sorbate uptake and release during experiments of ad- and desorption, respectively, which is comprised of a slow, hitherto unknown rate mechanism superimposed on very fast intracrystalline diffusion of carbon dioxide. IR-spectroscopic data that evidence formation of chemisorption species in CO2-NaX sorption systems may allow for a tentative interpretation of this finding. Circumstantial evidence for the correctness of this conclusion follows from sorption–kinetic experiments for carbon dioxide on BaKX-type zeolite crystals (mean crystal diameter: 2R (120 ± 6) m).  相似文献   

2.
The adsorptive and electrochemical behaviors of medecamycin were investigated on a glassy carbon electrode (GCE) pretreated by anodic oxidation at +1.8 V for 5 min in 0.025 mol l–1 NH3-NH4Cl (pH 8.6) solution. An adsorptive stripping voltammetric method for the determination of medecamycin at the pretreated glassy carbon electrode has been developed. Medecamycin was accumulated in NH3-NH4Cl buffer (pH 9.0) at a potential of –0.7 V (vs. saturated calomel electrode (SCE)) for a certain time, and then determined by second-order differential anodic stripping voltammetry. The second-order differential anodic stripping peak current at +0.72 V was proportional to the concentration of medecamycin in the range 2.0 g ml–1 to 50.0 g ml–1. The detection limit (three times the signal-to-noise) was 1.0 g ml–1 and the relative standard deviation of the results was 3.28% for eight successive determinations of 10.0 g ml–1 medecamycin. This method has been applied to the direct determination of medecamycin in commercial tablets and spiked urine samples with satisfactory results.  相似文献   

3.
Summary Due to manifold physiological and cardioprotective actions of adenosine, the demand for a simple but accurate method to determine its concentration in plasma is increasing. The aim of this study was firstly to develop a simple isocratic method instead of the gradient elution or peak-shifting techniques used earlier and secondly to check conflicting data on the composition of stop-solution, added to the sample in order to prevent changes in adenosine concentration. Isocratic elution improved signal to noise ratio and concentrations of 100 mol L–1 dipyridamole and 2.5 mol L–1 erythro-9(2-hydroxy-3-nonyl)adenine in the blood sample effectively prevented both adenosine formation and degradation, even without the use of a 5-ecto-nucleotidase inhibitor. Lowering the concentration of dipyridamole to 25 mol L–1 caused more than a tenfold increase of adenosine concentration in two out of five cases and even 100 mol L–1 dipyridamole alone is not sufficient to inhibit adenosine deaminase in blood samples.  相似文献   

4.
Summary Transition metal complexes of the composition [Fe(4-X-bzimpy)2](ClO4)2 [bzimpy = 2,6-bis-(benzimidazol-2-yl)pyridine and X=H, OH, Cl] show thermally accessible spin-crossover behaviour in solution that depends on both the ligand and the solvent.1H-NMR spectroscopy and UV-visible spectroscopy measurements suggest that ligand substituent effects, solvent donor-acceptor properties and hydrogen-bonding may be employed to fine-tune the ligand field strength and hence to affect the spin-crossover behaviour. The ligand substitution changes in solution are reflected by the magnetic data (X=H:exp=2.50 B; X=OH:exp=4.20 B and X=Cl:exp=4.30 B at 294 K in MeOH), and by the shift of metal-to-ligandcharge-transfer band (X=H, =557 nm; X=OH, =520 nm; X=Cl, =500 nm). [Fe(bzimpy)2](ClO4)2 exhibits a pronounced spin-crossover equilibrium (1A1 5T2) in solution (K sc=0.26 at 293 K; exp=1.30 3.40 B for 213 328 K in MeOH). A small variation of magnetic moments of [Fe(4-OH-bzimpy)2](ClO4)2 (exp=3.77 4.73 B at 220 332 K) might indicate either the existence of (temperature dependent) hydrogen bonding between the ligand and solvent molecules or a temperature dependent variation in the population of the5Eg sublevel. The presence of strong donor solvents (DN 30) shifts the spin-state of the complexes.In course of absence from the Chemistry Department, Jahangirnagar University, Dhaka, Bangladesh  相似文献   

5.
Nanometer-sized l-cysteine-capped ZnS particles have been synthesized and used as a fluorescence probe to investigate the effect of proteins on fluorescent intensity. With =190 nm, maximum and constant synchronous fluorescence enhancement was produced at 267 nm and pH 5.12 in the presence of proteins. A highly sensitive synchronous fluorescence method for the rapid determination of proteins has been developed. Under optimum conditions, calibration graphs are linear over the range 0.03–8.0 g mL–1 for bovine serum albumin (BSA), 0.01–6.0 g mL–1 for human serum albumin (HSA), 0.05–8.0 g mL–1 for -globulin (-G), and 0.04–4.0 g mL–1 for ovalbumin, respectively. The relative standard deviations of seven replicate measurements were 1.75% for 1.0 g mL–1 BSA, 1.90% for 1.0 g mL–1 HSA, 1.65% for 1.0 g mL–1 -G, and 2.32% for 1.0 g mL–1 ovalbumin.  相似文献   

6.
Roots of Tragacantha stipulosa Boriss yielded three triterpene glycosides of the cycloartane series: askendoside G (1), askendoside D (2), and cycloglobiceposide B (3). Glycoside 1 is 3-O--L-arabinopyranosyl-(12)--D-xylopyranoside; 16-O--D-glucopyranoside-24R-cycloartan-3,6,16,24,25-pentaol; 2 - 3-O--L-arabinopyranosyl-(12)--D-xylopyranoside; 6-O--D-xylopyranoside-20R,24S-epoxycycloartan-3,6,16,25-tetraol; 3 - 3-O--D-xylopyranoside; 16-O--D-glucopyranoside; 25-O--D-glucopyranoside-24R-cycloartan-3,6,16,24,25-pentaol.  相似文献   

7.
    
Zusammenfassung Die Elemente Sb, Sn, Se, As und Ge werden unter Zusatz von 100 g Cu als Träger und innerem Standard als Sulfide gefällt. Der Niederschlag wird auf einem Membranfilter gesammelt und das Filter direkt der Röntgenfluorescenzspektralanalyse unterworfen. Die praktisch erreichbare Nachweisbarkeitsgrenze liegt für Sb und Sn bei 2 g, für Se, As und Ge bei 1 g. Die Standardabweichung des Verfahrens beträgt 2,5% für Mengen von 100 g und 10% für Mengen von 5–10 g.
Summary Sb, Sn, Se, As and Ge are precipitated as sulphides with 100 g of Cu as carrier and inner standard. The precipitate is collected on a membrane filter and is used directly for X-ray spectrographic analysis. The limit of detection is 2 g for Sb and Sn, and 1 g for Se, As, and Ge. The standard deviation is 2.5% for amounts of 100 g, and 10% for amounts of 5–10 g.
  相似文献   

8.
Cyclic voltammetry and galvanostatic coulometry techniques were used to determine how the redox properties of osmium binuclear -oxocarboxylates [Os2 IV(-O)(-O2CR)2Cl4L2] (R = CH3, CCl3; L = PPh3 and R = CH3; L = AsPh3) are influenced by the nature of the bridging carboxylate ligand RCOO and ligand L. It was shown that all compounds in solution of dichloromethane undergo two single-electron reduction processes. The data obtained were compared with the DFT calculations of the electronic structure of the model complexes [Os2 IV(-O)(-O2CR)2Cl4L2] (R = CH3, CCl3; L = PH3 and R = CH3; L = AsH3).  相似文献   

9.
A rapid and sensitive spectrophotometric method is described for the determination of trace amounts of cerium using Variamine Blue (VB) as a chromogenic reagent. The proposed method is based on the reaction of cerium with potassium iodide in acidic medium to liberate iodine, which oxidizes Variamine Blue to give a violet colored species with an absorption maximum at 560nm. Beers law was obeyed in the range 2–10µg mL–1 of cerium. The molar absorptivity and Sandells sensitivity are found to be 1.65×104L mol–1cm–1 and 8.48×10–3µgcm–2, respectively. The proposed method has been successfully applied to the determination of cerium in alloy and synthetic mixtures.  相似文献   

10.
The reaction of the tetranuclear trimethylacetate complex Co4(3-OH)2(-OOCCMe3)4(2-OOCCMe3)2(EtOH)6 with pyridine in acetonitrile was studied. Two new compounds, viz., the hexanuclear cobalt(ii) complex Co6py4(3-OH)2(-OOCCMe3)10 (25% yield) and the unusual ionic compound [Co3py3(3-O)(-OOCCMe3)6]+[Co4py(4-O)(-OOCCMe3)7] (5% yield), were prepared. The structures of the new compounds were established by X-ray diffraction analysis.  相似文献   

11.
Summary In medium of pH=1, vanadium(V) forms a 1 1 cationic complex with PAR, the instability constant of the complex beingpK=5.6. In the presence of hydrogen peroxide a 111 mixed-complex develops which is uncharged. The molar absorptivity of the complex ( 540=1.28×104 l·mole–1·cm–1) provides a possibility for the spectrophotometric determination of 1–65M hydrogen peroxide.
Zusammenfassung In saurer Lösung (pH=1) bildet Vanadin(V) mit PAR einen positiv geladenen Komplex, dessen Komplexkonstante dem pK-Wert 5,6 entspricht. In Anwesenheit von Wasserstoffperoxid bildet sich mit diesem Kation ein ungeladener Mischkomplex im Verhältnis 111. Dessen Extinktionskoef-fizient ( 540=1,28×104 l · mol–1 · cm–1) ermöglicht die spektrophotometrische Bestimmung von Wasserstoffperoxid im Konzentrationsbereich von 1–65Mol/l.
  相似文献   

12.
A method has been developed for photometric detection of cyclodextrins (CD) in liquid chromatography using iodine (I2) generated electrochemically in-situ. Iodide ion in the mobile phase was electrochemically oxidized to I2 which was subsequently reacted with I, in an electrochemical flow cell, forming I3. The absorbance of I3 was found to be greatly enhanced when CD were present in the mobile phase. The absorbance enhancement was caused by the change in the mole fraction of I3, because of the inclusion reaction of I3 with CD. On the basis of this phenomenon, CD were detected by means of a photodiode-array UV–visible detector positioned downstream of the electrochemical flow cell. The signals were found to be linearly dependent on CD concentration. Because the formation constants of I3 with CD decrease in the order -CD>-CD>-CD, -CD was most detectable by the method. Detection limits were 1.0 mol L–1 for -CD, 65 mol L–1 for monoG1--CD, 100 mol L–1 for -CD, and 200 mol L–1 for -CD.  相似文献   

13.
A method for the determination of aldrin, dieldrin, DDT, DDE, and DDD contamination in animal fats (beef tallow, lard, and chicken fat) without using toxic reagents is developed, that uses high-performance liquid chromatography after the sample has been prepared by matrix solid-phase dispersion (MSPD) with acidic alumina oxide. A reversed-phase C1-silica column with a mobile phase of 50% (v/v) ethanol solution (in water) and a photo-diode array detector were used for the determination. Average recoveries of the target compounds (0.2–5.0 g g–1) ranged from 84–98%, with coefficients of variation of <5%. The limits of quantitation were 0.16 g g–1 for AD, 0.10 g g–1 for DD, 0.06 g g–1 for DDT, 0.07 g g–1 for DDE, and 0.05 g g–1 for DDD. No toxic reagents were used at all.  相似文献   

14.
Chemical behaviour of a helium muonide atom /Heo/ can be understood on the analogy of its hydrogen homologues, muonium /Mu/, deuterium /Do/ and tritium /To/. In muon catalyzed fusion /CF/, a small fraction of negative muon in the fusion cycle sticks to helium to give proton-like He+ which easily picks up one electron forming Heo. The energy of He+ at birth is about 3.5 MeV being in a similar situation to the case of a hot tritium atom produced by /n, p/ or /n, / reaction. The reaction cross section and rate of Heo reactions are estimated.  相似文献   

15.
Oxidoreductases and hydrolases isolated from different sources (horseradish and peanut peroxidases, alcohol dehydrogenases from bakers yeast and horse liver, and alkaline phosphatases from Escherichia coli, chicken and seal intestine) were used to determine their metal ion cofactors: Fe(III), Zn(II) and Mg(II), respectively. Studying the effects of the metal ion cofactors on the catalytic activity of the enzymes of different origin showed that the extent of their inhibition, activation, or reactivation of their apoenzymes depended on the structure and accessibility of the enzyme active site, which varies among the biocatalysts isolated from different sources. The developed procedures are based on the inhibiting (Zn(II)) or activating (Mg(II)) effects of the metal ions on the catalytic activity of the enzymes, or on reactivating effects (Fe(III) and Zn(II)) on the apoenzymes. The procedures are characterized by high sensitivity and selectivity; the detection limits of Fe(III) using horseradish peroxidase, Zn(II) using alcohol dehydrogenase from bakers yeast, alkaline phosphatase from seal intestine and its apoenzyme, and Mg(II) using alkaline phosphatase from chicken intestine equal 10 ng L–1, 20 ng L–1, 3 g L–1, 8 g L–1 and 0.2 g L–1, respectively.Presented at the 8th Symposium Kinetics in Analytical Chemistry, Rome, Italy, 5–8 July 2004.  相似文献   

16.
Zusammenfassung Eine neue Methode zur Durchführung gravimetrischer Bestimmungen im Mikrogrammbereich wurde beschrieben; diese beruht im wesentlichen darauf, daß der Niederschlag nicht mehr zusammen mit dem Filter, sondern nach Überführen mit einem geeigneten Lösungsmittel in einem separaten Wägegefäß gewogen wird.Die dazu nötigen Geräte und deren Herstellung wurden beschrieben. Nach dieser Methode wurden folgende Bestimmungen mit zufriedenstellender Richtigkeit durchgeführt: 2,5–25g Al, 5–50g Cu und 5–50g Zn mit Oxin, 2,5–25g Fe(III) und 2,5–25g Ti(IV) mit N-Benzoyl-phenylhydroxylamin, 5–50g Ni und 5–50g Cu mit Salicylaldoxim, 2,5–50g Co(II) und 2,5–50g Fe(III) mit -Nitroso--naphthol sowie 5–50g Chlorid als Silberchlorid.
Precipitation analysis in the microgram-scale: A new method
Summary A new method for gravimetric determinations in the microgram-scale is described. This method is based on the fact that the precipitate is not weighed together with the filter but is transferred to a separate weighingvessel using a suitable solvent. The necessary simple devices and their use are described. The following determinations were carried out with satisfying accuracy: 2,5–25g Al, 5–50g Cu and 5–50g Zn with Oxine, 2,5–25g Fe and 2,5–25g Ti withN-benzoylphenylhydroxylamine, 5–50g Ni and 5–50g Cu with salicylaldoxime, 2,52–50g Co and 2,5–50g Fe with -nitroso--naphthol and 5–50g chloride as silver chloride.
  相似文献   

17.
Thermosonimetry, DTA, high temperature XRD and hot stage microscopy have been used to study the thermal behaviour of K2Cr2O7. A rapid triclinic to monoclinic phase transformation occurs at 543 K slowly reversible at 508 K. Severe crystallite fracturing is associated with the reverse transition and manifests anomalous X-ray intensities which have been previously interpreted as metastable phase formation. On reheating, the transformation occurs at 528 K. Possible interpretations of the temperature hystereses are given.
Zusammenfassung Thermosonimetrie, DTA, Hochtemperatur-XRD und Mikroskopie in heißem Zustand wurden zur Untersuchung des thermischen Verhaltens von K2Cr2O7 eingesetzt. Eine schnelle Phasenänderung von der triklinen zur monoklinen Form findet bei 543 K statt, welche bei 508 K langsam reversibel ist. Der schwere Kristallbruch ist mit dem umgekehrten Übergang verbunden und weist anomale Röntgenstrahlen-Intensitäten auf, welche früher als Bildung einer metastabilen Phase gedeutet wurden. Bei wiederholtem Aufheizen geht die Änderung bei 528 K vor sich. Mögliche Deutungen der Temperaturhysterese werden gegeben.

Résumé On a étudié le comportement thermique de K2Cr2O7 par thermosonimétrie, ATD, diffraction des rayons X à haute température et microscopie avec platina chauffante. Une transformation rapide de la phase triclinique à la phase monoclinique a lieu à 543 K et est lentement réversible à 508 K. Un fractionnement important des cristallites est associé à la transition inverse et se manifeste par des intensités anormales des raies de diffraction X, ce qui a été préalablement interprété comme la formation d'une phase métastable. Lors d'un nouvel échauffement, la transformation a lieu à 528 K. Diverses interprétations possibles de l'hystérèse de température sont proposées.

227 - , , - . 543 - , 508 . - , . 528 . .
  相似文献   

18.
Summary A rapid ion-exchange method for the determination of 144Ce, 137Cs, 89Sr, 90Sr and 140Ba in 2–30 liter samples of atmospheric water precipitations is described. The samples, containing up to 300 mg of calcium, are sorbed on a specially shaped column filled with Dowex 50, X-8 or Dowex 50W, X-8. Radio-cerium and radio-caesium are stripped from the column with 0.6 M ammonium glycolate/ 0.2 M NaCl, pH 5, radio-strontium and radio-barium with 0.15 M ammonium citrate, pH 7.5. The isolated radio-nuclides are counted on a low-background beta-counter: 144Ce as CeO2, 137Cs as Cs-dipicrylaminate, 89Sr/90Sr as SrCO3, 90Y as Y2O3, and 140Ba as BaCO3. The mean chemical yields amount to 95% for cerium, 85% for caesium, 95% for strontium, 95% for yttrium and 65% for barium. With parallel determinations at levels of a few picocuries, the deviations of the results from the respective mean values generally do not exceed ± 5%. With a 30 l sample the limit of detection amounts to 0.005 Ci/l for 144Ce, 0.006 Ci/l for 137Cs, 0.005 Ci/l for 90Sr, and 0.006 Ci/l for 140Ba.
Zusammenfassung Es wird eine schnelle Ionenaustauschmethode für die Bestimmung von 144Ce, 137Cs, 89Sr, 90Sr und 140Ba in 2–30 l Proben von atmosphärischen Wasser-Niederschlägen beschrieben. Die Proben, mit einem Calciumgehalt bis zu 300 mg, werden in eine besonders gestaltete, mit Dowex 50, X-8 oder Dowex 50 W, X-8 gefüllte Säule eingewaschen. Radio-Cer und Radio-Caesium werden mit 0,6 M Ammoniumglykolat/0,2 M NaCl, pH 5, Radio-Strontium und Radio-Barium mit 0,15 M Ammoniumcitrat pH 7,5 eluiert. Die isolierten Radio-Nuklide werden in einem Beta-Antikoinzidenzzähler gemessen: 144Ce als CeO2, 137Cs als Cs-dipikrylaminat, 89Sr/90Sr als SrCO3, 90Y als Y2O3 und 140Ba als BaCO3. Die mittlere Rückgewinnung der zugesetzten Träger beträgt für Cer 95%, 85% für Caesium, 95% für Strontium, 95% für Yttrium und 65% für Barium. In Parallelbestimmungen mit Gehalten von einigen Ci/l, überschreiten die Abweichungen der Ergebnisse von den entsprechenden Mittelwerten im allgemein nicht 5%. Bei einer 30 l-Probe beträgt die untere Nachweisgrenze 0,005 Ci/l für 144Ce, 0,006 Ci/l für 137Cs, 0,005 Ci/l für 90Sr und 0,006 Ci/l für 140Ba.
  相似文献   

19.
Summary Laser microprobe mass analysis (LAMMA) was applied to characterize aerosol particles collected and separated from 16m to 0.06m by a low pressure cascade impactor. Positive ion LAMMA spectra showed characteristic molecular peaks such as PbCl+, a series of Si2O+–Si2O4 + and NaAl2Si2O2 +–NaAl2Si2O5 +, and TiO+ in 0.06–0.12m, 0.5–1m and 4–8m fraction, respectively. In the negative ion LAMMA spectra, it was observed that the fragment peaks of sulfate ions were deficient above 2m and those of nitrate ions were deficient under 2m. LAMMA allows remarkable insights into the chemical nature of aerosol particles.
Charakterisierung luftgetragener Teilchen durch Laser-Microprobe-Massenspektrometrie
Zusammenfassung Laser-Microprobe-Spektrometrie (LAMMS) wurde zur Analyse atmosphärischen Aerosols herangezogen, welches im Korngrößenbereich zwischen 16m und 0.06m mit einem Niederdruckkaskadenimpaktor fraktioniert gesammelt wurde. Positive LAMMS-Spektren zeigten charakteristische molekulare Peaks, wie etwa PbCl+, eine Serie von Si2O+–Si2O4 + und NaAl2Si2O2 +–NaAl2Si2O5 +, sowie TiO+ in der 0,06–0,12-m,- 0,5–1–m- bzw. 4–8-m-Fraktion. In den negativen LAMMS-Spektren konnten über 2m keine Fragmentpeaks für Sulfationen, unter 2m. keine für Nitrationen beobachtet werden. LAMMS ermöglicht eine bemerkenswerte Einsicht in die chemische Natur von Aerosolteilchen.
  相似文献   

20.
Zusammenfassung Es wird eine Methode beschrieben zur Bestimmung von 50 g bis 5 mg Ba durch Fällung als Chromat und spektrophotometrische Messung des gelösten Bariumchromats bei 3500 Å oder nach Zusatz von Diphenylcarbacid bei 5400 Å. Bei 350 g Ba verursachen Mengen bis 35 g Sr oder 150 g Ca keine wesentliche Störung. Die Standardabweichung wird in 3 Teile zerlegt, ein Teil ist der Konzentration proportional (0,3%), der zweite Teil davon unabhängig (3 g), der dritte entspricht dem Meßfehler des Spektrophotometers.Der Autor dankt Fräulein Y. de Wijs und den Herren M. A. van der Meer und C. van der Vlies für die gewissenhafte Ausführung der Versuche.  相似文献   