首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
We have developed screen–printed carbon electrodes for the determination of tyramine (Tyr) via plasma amine oxidase. The enzyme was immobilized on the carbon working electrode by cross–linking it with bovine serum albumin using glutaraldehyde. The employment of the mediator hydroxymethylferrocene lowers the working potential to +260 mV (vs. a screen–printed Ag/AgCl reference electrode). The effects of pH, potential and mediator concentration were optimized and resulted in reproducibility and repeatability values of 8.6 % and 8.7 %, respectively. Response is linear in the range from 2 to 164 μM, and the limit of detection is 2.0?±?0.18 μM. The effects of potentially interfering biogenic amines such as putrescine, cadaverine, histamine, spermine, spermidine and tryptamine were also evaluated. The biosensor was successfully applied to the determination of Tyr in cheese.
Figure
Amperometric determination of tyramine using a biosensor based on the immobilization of polyamine oxidase (PAO) enzyme on a disposable screen-printed carbon electrode.  相似文献   

2.
Cysteamine core polyamidoamine G-4 dendron branched with β-cyclodextrins was chemisorbed on the surface of Au electrodes and further coated with Pt nanoparticles. Adamantane-modified glucose oxidase was subsequently immobilized on the nanostructured electrode surface by supramolecular association. This enzyme electrode was used to construct a reagentless amperometric biosensor for glucose, making use of the electrochemical oxidation of H2O2 generated in the enzyme reaction. The amperometric response of the biosensor was rapid (6 s) and a linear function of glucose concentration between 5 and 705 μmol?L?1. The biosensor had a low detection limit of 2.0 μmol?L?1, sensitivity of 197 mA?mol?1?L?cm?2, and retained 94 % of its initial response after storage for nine days at 4 °C.  相似文献   

3.
A novel tyrosinase (Tyr) biosensor based on liposome bioreactor and chitosan (CS) nano-composite has been developed for the detection of phenolic compounds. Liposome-based bioreactors were prepared by encapsulating the enzyme Tyr in l-α-phosphatidylcholine liposome resulting in spherical bioreactor with a mean diameter of 8.5?±?1.25 μm. The encapsulation efficiency and drug loading content of the Tyr-loaded liposome-based bioreactors were about 46.35?±?0.85 and 41.15?±?0.95 %, respectively. Porins were embedded into the lipid membrane, allowing for the free substrate transport, but not that of the enzyme due to size limitations. The glassy carbon electrode (GCE) was alternately immersed in CS and Tyr liposome bioreactor (TLB) to assemble bilayer films [(CS/TLB)/GCE]. The presence of Tyr in the biosensor was confirmed by scanning electron microscopy, cyclic voltammetry, and electrochemical measurements. The results indicated that the biosensor was applied to detect phenol with a broad linear range from 0.25 nM to 25 μM, the detection limit was brought down to 0.091 nM. The apparent Michaelis–Menten constant, K m, for the enzymatic reaction was 34.78 μM. The novel biosensor exhibits good repeatability and stability. Such new biosensor based on encapsulation of Tyr within liposome bioreactors shows great promise for rapid, simple, and cost-effective analysis of phenolic contaminants in environmental samples. The proposed strategy can be extended for the development of other enzyme-based biosensors.  相似文献   

4.
Jing Chen  Yeling Jin 《Mikrochimica acta》2010,169(3-4):249-254
A sensitive tyrosinase biosensor, based on co-modifying tyrosinase and palygorskite on glassy carbon electrode, was developed for phenol analysis. Palygorskite, a kind of natural one-dimensional clay with good biocompatibility, high specific surface area and porous morphology, works as a perfect matrix of enzyme. Tyrosinase retains its inherent bioactivity when immobilized in palygorskite, which leads to a high sensitivity of 1.897 A mol?1 L. The sensor response achieves 95% of steady-state-current in no more than 3 s, and the linear range of the bioelectrode spans the concentration of phenol from 5?×?10?8 to 1?×?10?4 mol L?1 with a correlation coefficient of 0.9992. The results show no apparent decrease in the response over 2 weeks, and about 80% of the response was retained after 2 months when the electrode was stored at 4–5 °C.  相似文献   

5.
A novel hybrid epoxy/nano CaCO3 composite matrix for catalase immobilization was prepared by polymerizing epoxy resin in the presence of CaCO3 nanoparticles. The hybrid support was characterized using scanning electron microscopy and Fourier transform infrared spectroscopy. Catalase was successfully immobilized onto epoxy/nano CaCO3 support with a conjugation yield of 0.67?±?0.01 mg/cm2 and 92.63?±?0.80 % retention of activity. Optimum pH and optimum temperature of free and immobilized catalases were found to be 7.0 and 35 °C. The value of K m for H2O2 was higher for immobilized enzyme (31.42 mM) than native enzyme (27.73 mM). A decrease in V max value from 1,500 to 421.10 μmol (min mg protein)?1 was observed after immobilization. Thermal and storage stabilities of catalase improved immensely after immobilization. Immobilized enzyme retained three times than the activity of free enzyme when kept at 75 °C for 1 h and the half-life of enzyme increased five times when stored in phosphate buffer (0.01 M, pH 7.0) at 5 °C. The enzyme could be reused 30 times without any significant loss of its initial activity. Desorption of catalase from the hybrid support was minimum at pH 7.0.  相似文献   

6.
An amperometric tyramine biosensor based on poly‐L‐lysine (PLL) and Fe3O4 nanoparticles (Fe3O4NP) modified screen printed carbon electrode (SPCE) was developed. PLL was formed on the SPCE by the electropolymerization of L‐lysine. Subsequently, Fe3O4NP suspension prepared in chitosan (CH) solution was casted onto the PLL/SPCE. Tyrosinase (Ty) enzyme was immobilized onto the modified Fe3O4?CH/PLL/SPCE and the electrode was coated with Nafion to fabricate the Ty/Fe3O4?CH/PLL/SPCE. Different techniques including scanning electron microscopy, chronoamperometry (i–t curve), cyclic voltammetry and electrochemical impedance spectroscopy were utilized to study the fabrication processes, electrochemical characteristics and performance parameters of the biosensor. The analytical performance of the tyramine biosensor was evaluated with respect to linear range, sensitivity, limit of detection, repeatability and reproducibility. The response of the biosensor to tyramine was linear between 4.9×10?7–6.3×10?5 M with a detection limit of 7.5×10?8 M and sensitivity of 71.36 μA mM?1 (595 μA mM?1 cm?2). The application of the developed biosensor for the determination of tyramine was successfully tested in cheese sample and mean analytical recovery of added tyramine in cheese extract was calculated as 101.2±2.1 %. The presented tyramine biosensor is a promising approach for tyramine analysis in real samples due to its high sensitivity, rapid response and easy fabrication.  相似文献   

7.
A new conductometric enzyme-based biosensor was developed for the determination of formaldehyde (FA) in aqueous solutions. The biosensor was prepared by cross-linking formaldehyde dehydrogenase from Pseudomonas putida with bovine serum albumin in saturated glutaraldehyde vapours (GA) at the surface of interdigitated gold microelectrodes. Nicotinamide adenine dinucleotide cofactor (NAD+) was added in solution at each measurement to maintain enzyme activity. Addition of a Nafion layer over the enzyme modified electrode resulted in a significant increase of biosensor signal due to enhanced accumulation of protons generated by enzymatic reaction at the electrode surface. Different parameters affecting enzyme activity or playing a role in ionic transfer through the Nafion membrane were optimised. In optimal conditions (0.045 mg enzyme, 30 min exposure to GA, 0.3 μL of a 1 % (v/v) Nafion solution deposit, measurement in 5 mM phosphate buffer pH 7 containing 20 μM NAD+), the biosensor signal was linear up to 10 mM FA, and the detection limit was 18 μM. Relative standard deviations calculated from five consecutive replicates of FA solutions were lower than 5 % in the 1–10 mM range. The biosensor was successfully applied to the determination of FA in spiked water samples (tap water and Rhone river water), with recoveries in the 95–110 % range.
Figure
?  相似文献   

8.
A composite was prepared from copper and graphene oxide (Cu-GO) by in-situ chemical reduction of a mixture containing GO and Cu(II) ions with potassium borohydride. The morphology and structure of the composite were confirmed by various physicochemical techniques. The materials were used in a tyrosinase-based microbiosensor where the enzyme is immobilized in a biocompatible matrix consisting of poly(ortho-phenylene diamine) and Cu-GO. The composite was deposited on the surface of an 8-μm thick carbon fiber microelectrode. The role of each component in the sensing layer was systematically investigated with respect to the analytical performance of the system. In its optimal configuration, the biosensor demonstrated (a) a sensitivity of 6.1?±?3 nA mM-1 dopamine (DA), (b) a linear response to DA (with a Michaelis-Menten constant of 0.29?±?0.03 mM), (c) good selectivity over ascorbic acid and uric acid, and (d) a high blocking capacity (112.2?±?2 mM) for ascorbic acid.
Figure
Poly(o-phenylenediamine) electropolymerized carbon fiber electrode with sensitivity towards dopamine (DA) is 6.1?±?3 nA mM?1 supported by Cu-GO. The linear range for DA is 0.29?±?0.03 mM with 0.033 μM LOD and fast response time of <8 s with ascorbic acid blocking capacity of 112.2?±?2 mM AA. Studies on different ratio of Glu/Tyr revealed that 10:3 gave best overall response.  相似文献   

9.
Optimization of cultural conditions for enhanced cellulase production by Aspergillus niger NS-2 were studied under solid-state fermentation. Significant increase in yields (CMCase 463.9?±?20.1 U/g, FPase 101.1?±?3.5 U/g and β-glucosidase 99?±?4.0 U/g) were obtained under optimized conditions. Effect of different nutritional parameters was studied to induce the maximum production of cellulase complex. Scale-up studies for enzyme production process were carried out. Characterization studies showed that enzymes produced by A. niger NS-2 were highly temperature- and pH stable. At 50 °C, the half life for CMCase, FPase, β-glucosidase were approximately 240 h. Cellulases from A. niger NS-2 were stable at 35 °C for 24 h over a broader pH range of 3.0–9.0. We examined the feasibility of using steam pretreatment to increase the saccharification yields from various lignocellulosic residues for sugar release which can potentially be used in bioethanol production. Saccharification of pretreated dry potato peels, carrot peels, composite waste mixture, orange peels, onion peels, banana peels, pineapple peels by crude enzyme extract from A. niger NS-2, resulted in very high cellulose conversion efficiencies of 92–98 %.  相似文献   

10.
This article describes the investigation of direct electron transfer (DET) between glucose oxidase (GOD) and the electrode materials in an enzyme-catalyzed reaction for the development of improved bioelectrocatalytic system. The GOD pedestal electrochemical reaction takes place by means of DET in a tailored Vulcan carbon paste electrode surfaces with GOD and chitosan (CS), allowing efficient electron transfer between the electrode and enzyme. The key understanding of the stability, biocatalytic activity, selectivity, and redox properties of these enzyme-based glucose biosensors is studied without using any reagents, and the properties are characterized using electrochemical techniques like cyclic voltammogram, amperometry, and electrochemical impedance spectroscopy. Furthermore, the interaction between the enzyme and the electrode surface is studied using ultraviolet–visible (UV–Vis) and Fourier transform infrared (FTIR) spectroscopy. The present glucose biosensor exhibited better linearity, limit of detection (LOD?=?0.37?±?0.02 mol/L) and a Michaelis–Menten constant of 0.40?±?0.01 mol/L. The proposed enzyme electrode exhibited excellent sensitivity, selectivity, reproducibility, and stability. This provides a simple “reagent-less” approach and efficient platform for the direct electrochemistry of GOD and developing novel bioelectrocatalytic systems.  相似文献   

11.
A newly isolated thermophilic fungal strain from Tunisian soil samples was identified as Talaromyces thermophilus and was selected for its ability to produce extracellular hemicellulases when grown on various lignocellulosic substrates. Following the optimization of carbon source, nitrogen source, and initial pH of the growth medium in submerged liquid cultures, yields as high as 10.00?±?0.15 and 0.21?±?0.02 U/ml were obtained for xylanase and β-xylosidase, respectively. In fact, wheat bran was found to be a good inducer of hemicellulase enzymes, mainly β-xylosidase. The optimal temperature and pH of the xylanase activity were 75°C and 8.0, respectively. This enzyme exhibited a remarkable stability and retained 100% of its original activity at 50°C for 7 days at pH?7.0–8.0. The half-lives of the enzyme were 4 h at 80°C, 2 h at 90°C, and 1 h at 100°C. T. thermophilus could therefore be considered as a satisfactory and promising producer of thermostable xylanases. Crude enzyme of T. thermophilus rich in xylanase and β-xylosidase was established for the hydrolysis of lignocellulosic materials as wheat bran.  相似文献   

12.
A highly sensitive and stable amperometric tyrosinase biosensor has been developed based on multiwalled carbon nanotube (MWCNT) dispersed in mesoporous composite films of sol–gel‐derived titania and perfluorosulfonated ionomer (Nafion). Tyrosinase was immobilized within a thin film of MWCNT–titania–Nafion composite film coated on a glassy carbon electrode. Phenolic compounds were determined by the direct reduction of biocatalytically‐liberated quinone species at ?100 mV versus Ag/AgCl (3 M NaCl) without a mediator. The present tyrosinase biosensor showed good analytical performances in terms of response time, sensitivity, and stability compared to those obtained with other biosensors based on different sol–gel matrices. Due to the large pore size of the MWCNT–titania–Nafion composite, the present biosensor showed remarkably fast response time with less than 3 s. The present biosensor responds linearly to phenol from 1.0×10?7 M to 5.0×10?5 M with an excellent sensitivity of 417 mA/M and a detection limit of 9.5×10?8 M (S/N=3). The enzyme electrode retained 89% of its initial activity after 2 weeks of storage in 50 mM phosphate buffer at pH 7.0.  相似文献   

13.
This study demonstrates a miniaturized integrated glucose biosensor based on a carbon microbeads entrapped by glucose oxidase (GOx) immobilized on poly (N-isopropylacrylamide) (pNIPAm) microgels. Determined by the Lowry protein assay, the pNIPAm microgel possesses a high enzyme loading capacity of 31?mg/g. The pNIPAm GOx loaded on the microgel was found to maintain a high activity of approximately 0.140?U determined using the 4-aminoantipyrine colorimetric method. The integrated microelectrochemical cell was constructed using a microcentrifuge vial housing packed with (1:1, w/w) carbon entrapped by pNIPAm GOx microgels, which played the dual role of the microbioreactor and the working electrode. The microcentrifuge vial cover was used as a miniaturized reference electrode and an auxiliary electrode holder. The device can work as biosensor, effectively converting glucose to H2O2, with subsequent amperometric detection at an applied potential of ?0.4?V. The microelectrochemical biosensor was used to detect glucose in wide linear range from 30?µM to 8.0?mM, a low detection limit of 10?µM, a good linear regression coefficient (R2) of 0.994, and a calibration sensitivity of 0.0388?µA/mM. The surface coverage of active GOx, electron transfer rate constant (ks), and Michaelis–Menten constant (KMapp) of the immobilized GOx were 4.0?×?10?11?mol/cm2, 5.4?s?1, and 0.086?mM, respectively. To demonstrate the applicability and robustness of the biosensor for analysis of high sample matrix environment, glucose was analyzed in root beer. The microelectrochemical device was demonstrated for analysis of small sample (<50?µL), while affording high precision and fast signal measurement (≤5?s).  相似文献   

14.
An amperometric biosensor for dopamine is described. It is based on the enzyme monoamine oxidase immobilized on a glutaraldehyde-activated eggshell membrane that was deposited on a glassy carbon electrode. The Michaelis-Menten constant (Km) is 0.087 mM. Optimum pH and temperature conditions were obtained at pH 7.0 and 37 °C, respectively. The sensor showed a detection limit of 20 μM, a linear range from 50 μM to 250 μM, and a storage stability of ~25 days. In order to further improve the performance, a Nafion coating was applied on the electrode surface which gave favorable results with respect to shelf life of the enzyme (~40 days), the limit of detection, and the selectivity over ascorbic acid and uric acid.  相似文献   

15.
Carbon nanotubes (CNT)/Nafion-modified glassy carbon (GC) electrodes were used to immobilize the enzyme acetylcholinesterase (AChE) by crosslinking with glutaraldehyde. The CNT-modified electrodes exhibited a sensitive and stable electrocatalytic behavior towards thiocholine (TCh). Compared to ordinary GC electrodes modified with Nafion, a substantial (500-mV) decrease in the overvoltage of the TCh oxidation reaction is observed, along with a tenfold enhancement in the amperometric response. The CNT/Nafion/AChE electrode has very good stability of at least a month compared to surfaces made without crosslinking in the absence and presence of Nafion. Under optimal loadings of CNT, Nafion, AChE, and glutaraldehyde, a solution of CNT/Nafion in N,N-dimethylformamide (DMF) containing 4 mg/mL CNT and 0.01% Nafion was used to construct the electrodes in order to maximize the sensitivity of the biosensor for inhibition studies. An optimal enzyme loading of 0.137 U and crosslinking in 0.01% glutaraldehyde for 1 h was also needed to achieve this goal. The prepared electrodes had very good reproducibility to 1.0 mM acetylthiocholine (ATCh) (relative standard deviation [RSD] <5% for eight electrodes). Using paraoxon as a model pesticide, the biosensor was able to detect as low as 1.0 nM after 30 min of incubation at 30 °C. Using a log scale, the biosensor had good linearity in the concentration range 50?C800 nM, with a correlation coefficient of 0.99. The prepared biosensor was used to test real water samples spiked with paraoxon and showed good correlation with a calibration curve using phosphate buffer.  相似文献   

16.
Commercial lipase from Burkholderia cepacia is immobilized on functionalized multi-walled carbon nanotubes (MWNT-COOH and MWNT-OH) provided by a physical adsorption. The immobilization processes for the carbon nanotubes are defined using immobilization time (0–30 min) and distinct adsorbent:adsorbate ratios (1:4, 1:7, and 1:10) with lipase loading of 100, 175, and 250 mg, respectively. The characterization of the immobilized preparations, the free lipase, and the pure nanotubes (MWNT-COOH and MWNT-OH) indicate that the lipase adsorption is increased. Thermogravimetric analysis, differential scanning calorimetry, and scanning electron microscopy are used. The specific surface area, pore volumes, and average pore diameters are determined by nitrogen adsorption–desorption isotherms. For the pure lipase, in the range between 40 and 300 °C, the micrograph is acquired. Experimental results clearly show an effective lipase adsorption in a lower period of time (5 min) in MWNT-COOH and MWNT-OH as well as a decrease in the surface area (98.30–45.9(86)?±?2.5 and 97.61–37.71?±?3.3(7) m2 g?1) and the pore volume (0.48–0.25?±?0.01 and 0.39–0.24?±?0.05 cm3 g?1), indicating that functionalized multi-walled carbon nanotubes can be successfully used as enzyme support.  相似文献   

17.
Guanidino compounds guanidine, methylguanidine, guanidinoacetic acid, guanidinobutyric acid, guanidinopropionic acid, and guanidinosuccinic acid after derivatization with hexafluoroacetylacetone and ethyl chloroformate at pH 9 in aqueous phase, eluted, and separated from gas chromatographic column HP-5 (30 m × 0.32 mm id) with film thickness of 0.25 μm at an initial column temperature 90 °C for 2 min, followed by heating rate of 10 °C min?1 up to 220 °C with nitrogen flow rate of 1 mL min?1. The detection was by flame ionization detector. The linear calibration ranges of each of guanidino compounds were obtained within 1–10 μg mL?1, and the limit of detection was within 0.014–0.19 μg mL?1. The derivatization and gas chromatography elution and separation were repeatable in terms of retention time and peak height/peak area with relative standard deviation (RSD) (n = 4) within 1.7–2.9 % and 1.4–2.8 %, respectively. The method was applied for the determination of guanidino compounds from deproteinized serum of uremic patients and healthy volunteers, and was found in the range below the limit of quantitation (BLOQ) to 1.25 μg mL?1 with RSD within 1.4–3.6 %, and BLOQ to 0.4 μg mL?1 with RSD 1.3–3.4 %, respectively. A number of pharmaceutical additives did not effect the determination with RSD within ±3.1 %.  相似文献   

18.
We assessed the effects of ingesting caffeine before passive heat loading (PHL) on serum leptin and sweating response, which are both physiological responses associated with energy expenditure. The subjects were nine male university students (age, 24.1?±?3.5 years; height, 173.4?±?7.6 cm; weight, 69.2?±?5.7 kg; maximal oxygen consumption, 48.6?±?4.7 ml???kg?1???min?1). This study used a within-subject, random, crossover design. Tests were performed twice at the same time (2–5 p.m.) at a 1-week interval following 3 mg?kg?1 caffeine ingestion (Caff-I) or not (No-Caff). PHL included a half bath in hot water (42?±?0.5 °C for 30 min) in a thermoneutral climate chamber (25?±?0.5 °C, 60?±?3 % relative humidity, <1 m/s air velocity). After PHL, blood levels of leptin and free fatty acids were significantly higher in the Caff-I compared to those in the No-Caff after PHL (P?<?0.01). Waist circumference and whole-body sweat loss volume were significantly higher in the Caff-I compared to those in the No-Caff (P?<?0.001). Mean active sweat gland density was significantly higher in the Caff-I compared to those in the No-Caff at 10 min during PHL (P?<?0.001). The results suggest that ingesting caffeine before PHL is more energy efficient than that of a single PHL.  相似文献   

19.
By combination of 1-ethyl-3-methyl immidazolium ethyl sulfate as a typical room temperature ionic liquid (IL) and graphene oxide (GO) nanosheets, a nanocomposite was introduced for improving the direct electrochemistry and electrocatalytic activity of glucose oxidase (GOx). The enzyme on the IL–GO-modified glassy carbon electrode exhibited a quasireversible cyclic voltammogram corresponding to the flavine adenine dinucleotide/FADH2 redox prosthetic group of GOx. At the scan rate of 100 mV?s?1, the enzyme showed a peak-to-peak potential separation of 82 mV and the formal potential of ?463 mV (vs Ag/AgCl in 0.1 M phosphate buffer solution, pH?7.0). The kinetic parameters of the charge transfer rate constant, the electron transfer coefficient, and the apparent Michaelis–Menten constant were calculated as 1.36 s?1 and 0.35 and 2.47 μM, respectively. When the modified electrode was examined as a biosensor for glucose determination, a linear range of 2.5–45 nM with detection limit of 0.175 nM (signal to noise?=?3) was obtained. The biosensor was stable for 2 months.  相似文献   

20.
《Analytical letters》2012,45(18):3360-3372
Abstract

In this study, a novel type amperometric biosensor, which is based on the activation of catalase enzyme by glucose, was developed and used for the sensitive determination of glucose. For the preparation of the biosensor catalase enzyme was immobilized in gelatin by using cross‐linking agent glutaraldehyde and fixed on a pretreated teflon membrane of a dissolved oxygen probe. Glucose was used as an activator for the catalase enzyme and determination of glucose is based on the assay of the differences on the catalase activity of the biosensor on the oxygenmeter in the absence and the presence of glucose in the reaction medium. The responses of the activation based catalase biosensor have a linear relation to glucose concentrations and good measurement correlation between 0.5 and 5.0 µM with 2 min response time. In the optimization studies of the biosensor the most suitable catalase amount were found as 1324 U cm?2 and also phosphate buffer (pH: 7.0; 50 mM) and 35°C were obtained as the optimum working conditions. For the characterization studies of the biosensor some parameters such as activator and interference effects of some substances on the biosensor response, reproducibility and operational stability were performed.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号