首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 515 毫秒
1.
Native cyclodextrin-based columns are particularly useful for the analysis of oligosaccharides because the retention of these carbohydrates is based mainly on the hydrogen bonding interactions of oligosaccharide hydroxyl groups with the stationary phase. Thus, the retention time predictably increases with the number of analyte hydroxyl groups, which corresponds to the elongation of the oligosaccharide chain. High-performance liquid chromatography (HPLC) coupled to electrospray ionization (ESI) mass spectrometry (MS) was used for the separation and characterization of underivatized oligosaccharide mixtures. With the limits of detection as low as 50 pg, all individual components of oligosaccharide mixtures (up to 11 glucose units long) were baseline resolved on a Cyclobond I 2000 column and detected using ESI-MS. Low flow rates and narrow I.D. columns increase the ESI-MS sensitivity significantly. The method showed potential usefulness for the sensitive and quick analysis of hydrolysis products of polysaccharides, and for trace levels of individual oligosaccharide or oligosaccharide isomers from biological systems.  相似文献   

2.
We have developed a highly sensitive and positively charged precolumn derivatization reagent, (5‐N‐succinimidoxy‐5‐oxopentyl)triphenylphosphonium bromide (SPTPP), for amines and amino acids in liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI‐MS/MS). The handling of the derivatization reaction is quite simple and the reagent reacts with the analytes rapidly and with high efficiency. The derivatized analytes were observed to form regular and intense product ions upon MS/MS analysis; thus, highly sensitive and selective detection was possible in the selected reaction monitoring (SRM) mode. The limits of detection of the SPTPP‐derivatized analytes were less than sub‐femtomole levels. The sensitivities of the derivatized analytes increased about 500‐fold compared to those of underivatized analytes. Since the hydrophobicities of the samples increased after their derivatization, the resolution of the analytes improved dramatically when a reversed‐phase system was used. The relative standard deviations of intra‐day and inter‐day variations were below 10.6% and 13.3%, respectively. The accuracy ranged between 86.6–113% and 83.4–113%, respectively. Furthermore, the developed reagent was used for the analysis of the neurotransmitter 4‐aminobutanoic acid (GABA) and oxidative stress markers such as oxidized, nitrated, and halogenated tyrosines in rat serum. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

3.
Vickers JA  Henry CS 《Electrophoresis》2005,26(24):4641-4647
There is a need to develop broadly applicable, highly sensitive detection methods for microchip CE that do not require analyte derivatization. LIF is highly sensitive but typically requires analyte derivatization. Electrochemistry provides an alternative method for direct analyte detection; however, in its most common form, direct current (DC) amperometry, it is limited to a small number of easily oxidizable or reducible analytes. Pulsed amperometric detection (PAD) is an alternative waveform that can increase the number of electrochemically detectable analytes. Increasing sensitivity for electrochemical detection (EC) and PAD requires the isolation of detection current (nA) from the separation current (muA) in a process generally referred to as current decoupling. Here, we present the development of a simple integrated decoupler to improve sensitivity and its coupling with PAD. A Pd microwire is used as the cathode for decoupling and a second Au or Pt wire is used as the working electrode for either EC or PAD. The electrode system is easy to make, requiring no clean-room facilities or specialized metallization systems. Sensitive detection of a wide range of analytes is shown to be possible using this system. Using this system we were able to achieve detection limits as low as 5 nM for dopamine, 74 nM for glutathione, and 100 nM for glucose.  相似文献   

4.
Many pharmaceutical genotoxic impurities are neutral molecules. Trace level analysis of these neutral analytes is hampered by their poor ionization efficiency in mass spectrometry (MS). Two analytical approaches including chemical derivatization and coordination ion spray-MS were developed to enhance neutral analyte detection sensitivity. The chemical derivatization approach converts analytes into highly ionizable or permanently charged derivatives, which become readily detectable by MS. The coordination ion spray-MS method, on the other hand, improves ionization by forming neutral-ion adducts with metal ions such as Na+, K+, or NH4+ which are introduced into the electrospray ionization source. Both approaches have been proven to be able to enhance the detection sensitivity of neutral pharmaceuticals dramatically. This article demonstrates the successful applications of the two approaches in the analysis of four pharmaceutical genotoxic impurities identified in a single drug development program, of which two are non-volatile alkyl chlorides and the other two are epoxides.  相似文献   

5.
The mechanism underlying the enrichment power by pressure-assisted electrokinetic injection (PAEKI) in capillary electrophoresis (CE) was investigated for on-line pre-concentration of arsenic [As(III) and As(V)], selenium [Se(IV) and Se(VI)] and bromate (BrO(3)(-)). Analyte diffusion behaviour from PAEKI sample plugs were evaluated by monitoring peak broadening as a function of stagnant time and position in the capillary. During PAEKI, anionic analytes accumulate at the sample-separation buffer boundary. We proposed that a counter-ion layer formed in PAEKI, where a cation layer was formed at the separation buffer side of boundary. The cation layer served as a soft boundary which impeded zone broadening via electrostatic attraction between layers. This effect likely played an important role in maintaining focused analyte bands by suppressing diffusion. Comparison of analyte behaviour in PAEKI injected sample plugs to behaviour in hydrodynamically injected ones proved the existence of a counter-ion layer. The dependence of analyte diffusion in PAEKI plugs on electrochemical properties (viscosity, conductivity, electrophoretic mobility) further supported the hypothesis. Additionally, it was noted that analytes with low electrophoretic mobility were more efficiently pre-concentrated by PAEKI and were less subject to forces of dispersion than analytes with greater electrophoretic mobility. PAEKI-CE coupled to electrospray tandem mass spectroscopy (ESI-MS/MS) was then optimized and validated for detection of arsenic, selenium and bromate in water samples. On-line enrichment of the target analytes was achieved with 1-3 ng mL(-1) detection limits, which was below the maximum contaminant levels in drinking water for all five anions studied. Noteworthy, the potential of the method for unbiased detection of molecular species in untreated water was demonstrated. No contamination was detected in the water samples tested; however, recovery was 90-118% for spiked samples. The method was demonstrated be comparable to current methods for detection of inorganic contaminants in drinking water and is a good alternative method to ion chromatography/liquid chromatography-MS.  相似文献   

6.
In those cases where the information obtained by peptide mass fingerprinting or matrix-assisted laser desorption/ionization tandem mass spectrometry (MALDI-MS/MS) is not sufficient for unambiguous protein identification, nano-electrospray ionization (nano-ESI) and/or electrospray ionization tandem mass spectrometry (ESI-MS/MS) analysis must be performed. The sensitivity of nano-ESI/MS, however, is lower than that of MALDI-MS, especially at very low analyte concentrations and/or in the presence of contaminants, such as salt and detergents. Moreover, to perform ESI-MS/MS, the peptide masses of the precursor ions must be known. The approach described in this paper, MALDI-directed nano-ESI-MS/MS, makes use of information obtained from the more sensitive MALDI-MS experiments in order to direct subsequent nano-ESI-MS/MS experiments. Peptide molecular ions found in the MALDI-MS analysis are then selected, as their (+2) precursor ions, for nano-ESI-MS/MS sequencing, even though these ions cannot be detected in the ESI-MS spectra. This method, originally proposed by Tempst et al. (Anal. Chem. 2000, 72: 777-790), has been extended to provide better sensitivity and shorter analysis times; also, a comparison with liquid chromatography/tandem mass spectrometry (LC/MS/MS) has been performed. These experiments, performed using quadrupole time-of-flight instruments equipped with commercially available nano-ESI sources, have allowed the unambiguous identification of in-gel digested proteins at levels below their ESI-MS detection limits, even in the presence of salts and detergents.  相似文献   

7.
The retrospective detection and identification of degradation products of chemical warfare agents are of immense importance in order to prove their spillage and use. A highly sensitive liquid chromatography/electrospray ionization tandem mass spectrometric (LC/ESI-MS/MS) method--using an imidazolium-based tricationic reagent--was developed for the detection and identification of the anionic degradation products of nerve agents. A commercially available solution of 1,3-imidazolium-bis-(1-hexylbenzylimidazolium) trifluoride (IBHBI) formed adducts with alkylphosphonic acids (APAs), allowing detection of the APAs by positive mode ESI-MS. Tandem mass spectrometry was used for the unambiguous identification of the APAs. Parameters influencing the formation and stability of these adduct during mass spectrometric analysis, such as solvent composition, concentration of IBHBI, effect of pH and interferences by salts, were optimized. The absolute limits of detection (0.1 ng) for achieved for the APAs were better than those previously reported, and linear dynamic ranges of 10-2000 ng mL(-1) were achieved. The method was repeatable with a relative standard deviation ≤7.3%. APAs present in aqueous samples provided by the Organization for the Prohibition of Chemical Weapons during the 22(nd) and 24(th) Official Proficiency tests were detected and identified as IBHBI adducts. The added advantage of this method is that low-mass analytes are detected at higher mass, thus obviating the problem with background noise at low mass.  相似文献   

8.
Quantification of trace concentrations of transformation products of rocket fuel unsymmetrical dimethylhydrazine (UDMH) in water requires complex analytical instrumentation and tedious sample preparation. The goal of this research was to develop a simple and automated method for sensitive quantification of UDMH transformation products in water using headspace (HS) solid-phase microextraction (SPME) in combination with GC-MS and GC-MS/MS. HS SPME is based on extraction of analytes from a gas phase above samples by a micro polymer coating followed by a thermal desorption of analytes in a GC inlet. Extraction by 85 µm Carboxen/polydimethylsiloxane fiber at 50 °C during 60 min provides the best combination of sensitivity and precision. Tandem mass spectrometric detection with positive chemical ionization improves method accuracy and selectivity. Detection limits of twelve analytes by GC-MS/MS with chemical ionization are about 10 ng L?1. GC-MS provides similar detection limits for five studied analytes; however, the list of analytes detected by this method can be further expanded. Accuracies determined by GC-MS were in the range of 75–125% for six analytes. Compared to other available methods based on non-SPME sample preparation approaches (e.g., liquid–liquid and solid-phase extraction), the developed method is simpler, automated and provides lower detection limits. It covers more UDMH transformation products than available SPME-based methods. The list of analytes could be further expanded if new standards become available. The developed method is recommended for assessing water quality in the territories affected by space activities and other related studies.  相似文献   

9.
陈婷  温裕云  欧延  弓振斌 《色谱》2014,32(1):89-94
建立了固相萃取(SPE)净化、超高效液相色谱-串联质谱(UHPLC-MS/MS)测定橡胶制品中13种N-亚硝胺的方法。样品于密闭萃取瓶中于60 ℃下用甲醇超声萃取30 min,C18固相萃取小柱对萃取液进行净化,经C18色谱柱分离,最后用电喷雾正离子(ESI+)和多重反应监测模式(MRM)对13种N-亚硝胺进行定性、定量测定。实验中对样品前处理、色谱分离条件和质谱检测条件进行了优化。在优化的实验条件下,橡胶样品中添加N-亚硝基二甲胺(NDMA)与N-亚硝基-二乙基胺(NDEA)为500 μg/kg、其他组分均为50 μg/kg时,各组分的相对标准偏差(RSD,n=7)小于10%;在实际样品中的加标回收率为70.7%~117.0%;方法的检出限(LOD,以10倍标准偏差计)为0.5~500 μg/kg。方法可应用于橡胶制品中13种N-亚硝胺的测定。  相似文献   

10.
The capabilities of atmospheric pressure chemical ionization (APCI) and electrospray ionization (ESI) methods for quantitative analysis of polar and ionic compounds in petroleum fractions have been examined. The requirements of the analysis for sensitivity, linear dynamic range, and structural characterization have been discussed. ESI was found to be approximately two orders of magnitude more sensitive than APCI and is most suitable for the detection of analytes in weak concentrations. Equivalent relative linear dynamic ranges were observed by the two methods (at least three orders of magnitude). For the relatively high analyte concentrations examined here (e.g., 1-100 ppm or higher), the absolute area counts increased linearly with the analyte amount only in APCI, making this method more attractive for quantitative liquid chromatography/mass spectrometry (LC/MS) applications. Nevertheless, a wider range of ionic compounds can be detected by ESI than by APCI.  相似文献   

11.
A selective, sensitive and rapid liquid chromatography-tandem mass spectrometry method has been developed for the determination of caudatin-2,6-dideoxy-3-O-methy-beta-d-cymaropyranoside (CDMC) in rat plasma. This method involves a plasma clean-up step using liquid-liquid extraction, followed by LC separation and positive electrospray ionization mass spectrometry detection (LC/ESI-MS/MS). Chromatographic separation of the analytes was achieved using a C(18) column with a mobile phase of acetonitrile and water (70:30, v/v) at a flow rate of 1.0 mL/min. Low energy collision tandem mass spectrometric analysis (CID-MS/MS) using the multiple reaction monitoring (MRM) mode was used for analyte quantification. For the MRM analysis of CDMC, the following transition at m/z 658.4 --> 529.6 derived from the protonated molecule [M + Na](+). A calibration curve was linear in the 5-500 ng/mL range for CDMC, and the limit of detection was 5 ng/mL. The inter- and intra-day precisions (RSD) were 相似文献   

12.
Chemical probes are valuable tools for the investigation of biochemical processes, diagnosis of disease markers, detection of hazardous compounds, and other purposes. Therefore, the development of chemical probes continues to grow through various approaches with different disciplines and design strategies. Fluorescent probes have received much attention because they are sensitive and easy-to-operate, in general. To realize desired selectivity toward a given analyte, the recognition site of a fluorescent probe is designed in such a way to maximize the binding interactions, usually through weak molecular forces such as hydrogen bonding, toward the analyte over other competing ones. In addition to such a supramolecular approach, the development of fluorescent probes that sense analytes through chemical reactions has witnessed its usefulness for achieving high selectivity, in many cases, superior to that obtainable by the supramolecular approach. Creative incorporations of the reactive groups to latent fluorophores have provided novel chemical probes for various analytes. In this feature article, we overview the recent progress in the development of turn-on fluorescent probes that are operating through chemical reactions triggered by target analytes. Various chemical reactions have been implemented in the development of many reactive probes with very high selectivity and sensitivity toward target analytes. A major emphasis has been focused on the type of chemical reactions utilized, with the hope that further explorations can be made with new chemical reactions to develop reactive probes useful for various applications.  相似文献   

13.
An on-line liquid chromatography/tandem mass spectrometry (LC-MS/MS) procedure, using the Prospekt- 2 system, was developed and used for the determination of the levels of the active ingredients of cough/cold medications in human plasma matrix. The experimental configuration allows direct plasma injection by performing on- line solid phase extraction (SPE) on small cartridge columns prior to elution of the analyte(s) onto the analytical column and subsequent MS/MS detection. The quantitative analysis of three analytes with differing polarities, dextromethorphan (DEX), dextrorphan (DET) and guaifenesin (GG) in human plasma presented a significant challenge. Using stable-isotope-labeled internal standards for each analyte, the Prospekt-2 on-line methodology was evaluated for sensitivity, suppression, accuracy, precision, linearity, analyst time, analysis time, cost, carryover and ease of use. The lower limit of quantitation for the on-line SPE procedure for DEX, DET and GG was 0.05, 0.05 and 5.0 ng mL(-1), respectively, using a 0.1 mL sample volume. The linear range for DEX and DET was 0.05-50 ng mL(-1) and was 5-5,000 ng mL(-1) for GG. Accuracy and precision data for five different levels of QC samples were collected over three separate days. Accuracy ranged from 90% to 112% for all three analytes, while the precision, as measured by the %RSD, ranged from 1.5% to 16.0%  相似文献   

14.
A method using reversed phase high performance liquid chromatography/electrospray ionization-mass spectrometry (RP-LC/ESI-MS) has been developed to confirm the identity of dansylated derivatives of cysteine (C) and glutathione (GSH), and their respective dimers, cystine (CSSC) and glutathione disulfide (GSSG). Cysteine, GSH, CSSC and GSSG are present at low concentrations in rainbow trout (Oncorhynchus mykiss) liver cells. Initially, hepatic cells were sampled from a suspension culture and disrupted upon addition of 10% perchloric acid. The reduced thiols present in the cell extracts were acetylated to prevent dimerization and then the C and GSH species were derivatized with dansyl chloride for fluorescence detection. An LC system using a weak anion exchange column (AE) with fluorescence detection (FLD) was used for sensitive routine analysis; however, it produced peaks of unknown origin in addition to the expected analytes. Analytes were then separated on a C18 RP-LC system using a water/acetonitrile gradient with 0.2% formic acid, and detected using LC/ESI-MS at 3.5 KV which produced an intense ion with a minimum limit of detection of less than 0.5 pmole injected (>10:1 signal-to-noise (S/N). Subsequently, fractions of effluent from the AE-LC/FLD system were analyzed by LC/ESI-MS to confirm the presence of the target analytes in routine cell extracts. Monodansylated GSSG was identified as a product that could possibly affect the quantification of GSH and GSSG.  相似文献   

15.
《Analytical letters》2012,45(16):2912-2922
Abstract

Random metabolites present in a complex matrix can be characterized and quantified by a fast and robust liquid chromatography/mass spectra (LC/MS) method using the LTQ linear ion trap MS system. The experimental results showed excellent selectivity, precision, and sensitivity. The LTQ linear ion trap MS was found to be an excellent and highly selective instrument for measuring metabolites such as creatinine and cortisol present in complex matrices, even when such analytes were present at trace levels.  相似文献   

16.
Within the European Union the use of anabolic steroids for promoting growth and improving meat-to-fat ratio in food-producing animals has been banned since 1988. For the unequivocal identification of hormone residues in a complex matrix such as meat we have developed a rapid, specific and sensitive liquid chromatography/tandem mass spectrometry (LC/MS/MS) method, in combination with a simple extraction procedure based on the matrix solid-phase dispersion (MSPD). The performances of a triple quadrupole (QqQ) and a quadrupole/time-of-flight (QqTOF) were compared: the QqQ mass spectrometer was found to be more sensitive for almost all studied analytes, but the selectivity was superior using the QqTOF system; the full-scan spectra (acquired without losing sensitivity), mass accuracy and resolution of the hybrid instrument enabled a more probatory analyte identification than that obtained selecting two multiple-reaction monitoring (MRM) transitions with a QqQ. Average recoveries ranged from 80 to 100%, and the detection capabilities (CCbetas) were less than 1.06 ppb with the QqQ instrument and less than 5.20 ppb with the QqTOF instrument for the bovine meat, which proved to be the most complex matrix.  相似文献   

17.
Harms D  Luftmann H  Müller FK  Krebs B  Karst U 《The Analyst》2002,127(11):1410-1412
A highly selective method for the determination of hydrogen peroxide is presented. In a flow injection analysis (FIA) instrument, the analyte is brought into contact with a dinuclear heptadentate iron(III) complex. The formation of the peroxide adduct is quantified using electrospray tandem mass spectrometry (ESI-MS/MS). Selected reaction monitoring (SRM) based on the transition from the triply charged peroxide adduct with m/z = 251.2 to the triply charged fragment ion of m/z = 240.5 is performed. The limit of detection for hydrogen peroxide is 10(-7) mol dm(-3), limit of quantification is 3 x 10(-7) mol dm(-3), and a linear range of 2.5 decades starting at the limit of quantification is observed.  相似文献   

18.
Steroid sex hormones and related synthetic compounds have been shown to provoke alarming estrogenic effects in aquatic organisms, such as feminization, at very low concentrations (ng/L or pg/L). In this work, different chromatographic techniques, namely, gas chromatography/mass spectrometry (GC/MS), liquid chromatography/mass spectrometry (LC/MS) and liquid chromatography/tandem mass spectrometry (LC/MS/MS), are discussed for the analysis of estrogens, both free and conjugated, and progestogens, and the sensitivities achieved with the various techniques are inter-compared. GC/MS analyses are usually carried out after derivatization of the analytes with bis(trimethylsilyl)trifluoroacetamide (BSTFA). For LC/MS and LC/MS/MS analyses, different instruments, ionization techniques (electrospray (ESI) and atmospheric pressure chemical ionization (APCI)), ionization modes (negative ion (NI) and positive ion (PI)) and monitoring modes (selected ion monitoring (SIM) and selected reaction monitoring (SRM)) are generally employed. Based on sensitivity and selectivity, LC/ESI-MS/MS is generally the method of choice for determination of estrogens in the NI mode and of progestogens in the PI mode (instrumental detection limits (IDLs) 0.1-10 ng/mL). IDLs achieved by LC/ESI-MS in the SIM mode and by LC/ESI-MS/MS in the SRM mode were, in general, comparable, although the selectivity of the latter is significantly higher and essential to avoid false positive determinations in the analysis of real samples. Conclusions and future perspectives are outlined.  相似文献   

19.
Phospholipids make up one of the more important classes of biological molecules. Because of their amphipathic nature and their charge state (e.g., negatively charged or zwitterionic) detection of trace levels of these compounds can be problematic. Electrospray ionization mass spectrometry (ESI-MS) is used in this study to detect very small amounts of these analytes by using the positive ion mode and pairing them with fifteen different cationic ion pairing reagents. The phospholipids used in this analysis were phosphatidylethanolamine (PE), phosphatidylcholine (PC), phosphatidylglycerol (PG), phosphatidylserine (PS), phosphatidylinositol (PI), phosphatidic acid (PA), 1,2-diheptanoyl-sn-glycero-3-phosphocholine (DHPC), cardiolipin (CA) and sphingosyl phosphoethanolamine (SPE). The analysis of these molecules was carried out in the single ion monitoring (SIM) positive mode. In addition to their detection, a high performance liquid chromatography and mass spectrometry (HPLC-MS) method was developed in which the phospholipids were separated and detected simultaneously within a very short period of time. Separation of phospholipids was developed in the reverse phase mode and in the hydrophilic interaction liquid chromatography (HILIC) mode HPLC. Their differences and impact on the sensitivity of the analytes are compared and discussed further in the paper. With this technique, limits of detection (LODs) were very easily recorded at low ppt (ng L(-1)) levels with many of the cationic ion pairing reagents used in this study.  相似文献   

20.
The determination and quantitation of drugs in biological matrices using high-performance liquid chromatography/tandem mass spectrometry (HPLC/MS/MS) is becoming increasingly popular in analytical toxicology, while at the same time a growing awareness for the limits of this technique can be observed. Our group previously developed a rapid HPLC/ESI-MS/MS method for the detection and quantitation of succinylcholine (SUX) and succinylmonocholine (SMC) using ion-pairing extraction of samples with subsequent separation by gradient chromatography on a Synergi Hydro RP C18 column (4 microm, 150 x 2 mm). Identification of analytes was achieved in the multiple reaction monitoring (MRM) mode, using two characteristic ion transitions each, the respective analytes' retention time as well as co-elution of stable isotopic analogues.In both native serum as well as urine an interference with the main MRM transition of SMC was found to co-elute with this analyte, thus severely compromising the identification and quantitation of this target analyte. The interference was further shown to be eliminated from serum and urine by exposure to alkaline conditions and hence proven to share a key physicochemical property with SMC. The observed absence of the second and third most intense ion transitions of SMC in the unknown substance was the only useful distinction between both compounds.The detailed presentation of selectivity problems encountered during method development is intended to initiate further discussion on this yet underrepresented issue in HPLC/MS/MS. The present work emphasizes the need to monitor more than just one ion transition to confidently rule out signal interferences, ensure correct analyte identification as well as quantitation, and thus avoid false-positive results. In this context, the employment of minor MRM transitions for the quantitation and identification of a given analyte is presented as a satisfactory solution to HPLC/MS/MS selectivity problems, and proposed as a possible alternative to previously published approaches.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号