首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 739 毫秒
1.
A microdialysis method followed by a microbore liquid chromatographic ultraviolet detection procedure has been performed for the assay of unbound cefsulodin in rat blood. A microdialysis probe was inserted into the jugular vein for blood sampling. This method involves an on-line design for submitting dialysate into the liquid chromatographic system. The chromatographic conditions consisted of a mobile phase of methanol-100 mM monosodium phosphoric acid (10:90, v/v, pH 5.0) pumped through a microbore reversed-phase column at a flow-rate of 0.05 ml/min. Detection wavelength was set at 265 nm. Microdialysis probes, being laboratory-made, were screened for acceptable in vivo recovery while chromatographic resolution and detection were validated for response linearity as well as intra- and inter-day variabilities. The method was then applied to pharmacokinetics profiling of cefsulodin in the blood following intravenous administration of cefsulodin (20 mg/kg) in rats. Pharmacokinetics were calculated from the corrected data for dialysate concentrations of cefsulodin versus time. Based on pharmacokinetic calculation, cefsulodin best fitted to a two-exponential disposition. This study provided specific pharmacokinetic information for protein-unbound cefsulodin and demonstrated the applicability of this continuous sampling method for pharmacokinetic study.  相似文献   

2.
A technique involving rapid sampling of cephaloridine in rat blood was achieved using a combination of microdialysis and sensitive microbore liquid chromatography. A microdialysis probe was inserted into the jugular vein/right atrium of a Sprague-Dawley rat. Then after a real-time collection of the analyte by microdialysis, the dialysate was automatically injected into a liquid chromatographic system via an on-line injector. Following a 2 h stabilization period after the surgical procedure, cephaloridine (20 mg/kg, i.v.) was then administered via the femoral vein. Isocratic elution of cephaloridine was carried out with a mobile phase containing methanol-20 mM monosodium phosphate (25:75, v/v, pH 5.5), and the flow rate of the mobile phase was 0.05 mL/min within 10 min. Intra- and inter-assay accuracy and precision of the assay were each less than 10%. The in vivo recovery of the cephaloridine from the microdialysate was 49.7 +/- 8.0% and 42.4 +/- 8.4% for 0.5 and 1 microg/mL standards (n = 6), respectively. Based on the pharmacokinetic analysis, the elimination half-life was 32.2 +/- 8.6 min by cephaloridine administration (20 mg/kg, i.v., n = 6).  相似文献   

3.
A sensitive microbore liquid chromatographic method combined with the minimally invasive technique of microdialysis was devised for simultaneously and continuously monitoring the levels of unbound blood and brain cefazolin in rats. Microdialysis probes were inserted into the jugular vein and brain striatum for blood and brain sampling, respectively. Chromatographic conditions consisted of a mobile phase of methanol-acetonitrile-100 mM monosodium phosphoric acid (20:10:70, v/v, pH 4.5) pumped through a microbore reversed-phase column at a flow rate of 0.05 mL/min. The ultraviolet detection wavelength was set at 270 nm. An on-line design allowed direct and continuous analysis of protein-free samples in the dialysate. Microdialysis probes, being home-made, were screened for acceptable in vivo recovery. Chromatographic resolution and detection were validated for response linearity as well as intra-day and inter-day variabilities. This method was then applied to pharmacokinetic profiling of protein unbound cefazolin in both the blood and brain following intravenous administration (10 mg/kg, i.v., n = 6). Rapid appearance of cefazolin in the rat brain striatal dialysate following drug injection suggested good blood-brain barrier penetration. According to a non-compartmental pharmacokinetics model, the area under the concentration (AUC) vs time ratio of cefazolin in rat brain and blood was 6%.  相似文献   

4.
To investigate the pharmacokinetics of unbound chlorogenic acid, a sensitive microbore liquid chromatographic method for the determination of chlorogenic acid in rat blood by microdialysis has been developed. A microdialysis probe was inserted into the jugular vein of male Sprague–Dawley rats, to which chlorogenic acid (20, 40, 60 or 80 mg/kg, i.v.) had been administered. On-line microdialysate was directly injected into a microbore column using a methanol–100 mM sodium dihydrogenphosphate (30:70, v/v, pH 2.5 adjusted with orthophosphoric acid) as the mobile phase and ultraviolet detection at 325 nm. The method is rapid, easily reproduced, selective and sensitive. The limit of detection for chlorogenic acid was 0.01 μg/ml and the limit of quantification was 0.05 μg/ml. The in vivo recovery of the chlorogenic acid of the microdialysis probe, based on a 5 μg/ml standard, was approximately 49–65% (n=6). The disposition of chlorogenic acid at each dose was best fitted to a two-compartment pharmacokinetic model. The area under the concentration curve increased greater than in direct proportion with the dose and terminal disposition become much slower as the dose was increased. The results indicated that the pharmacokinetics of unbound chlorogenic acid in rat blood is non-linear.  相似文献   

5.
Salvianolic acid B is an herbal ingredient isolated from Salvia miltiorrhiza. An in vivo microdialysis sampling method coupled to high-performance liquid chromatography has been developed for continuous monitoring of protein-unbound salvianolic acid B in rat blood and bile. Microdialysis probes were inserted into the jugular vein/right atrium and bile duct of Sprague-Dawley rats, and a dose of 100 mg/kg salvianolic acid B was then administered via the femoral vein. Dialysates were collected and directly injected into a liquid chromatographic system. Salvianolic acid B was eluted using a microbore reversed-phase ODS 5 microm (150 mm x 1 mm I.D.) column. Isocratic elution of salvianolic acid B was achieved within 10 min using the liquid chromatographic system. The chromatographic mobile phase consisted of acetonitrile-methanol-20 mM monosodium phosphoric acid (pH 3.5) (10:30:60, v/v/v) containing 0.1 mM 1-octanesulfonic acid with 0.05 ml/min. The wavelength of the UV detector was set at 290 nm. Salvianolic acid B in both blood and bile dialysates was adequately determined using the liquid chromatographic conditions described, although the blank bile pattern was more complex. The retention times of salvianolic acid B in rat blood and bile dialysates were found to be 7.2 min. Peak-areas of salvianolic acid B were linear (r2 > 0.995) over a concentration range of 0.1-50 microg/ml. In vivo recoveries of microdialysis probes of salvianolic acid B in rat blood and bile averaged 22 +/- 2% and 41 +/- 1%, respectively. This study indicates that salvianolic acid B undergoes hepatobiliary excretion.  相似文献   

6.
To analyze unbound cefamandole in rat blood, a method combing microdialysis with microbore liquid chromatography has been developed. A microdialysis probe was inserted into the jugular vein/right atrium of male Sprague-Dawley rats to examine the unbound cefamandole level in the rat blood following cefamandole administration (50 mg/kg, i.v.). The dialysates were directly submitted to a liquid chromatographic system. Samples were eluted with a mobile phase containing acetonitrile-methanol-100 mM monosodium phosphate (pH 5.0; 15:20:65, v/v). The UV wavelength was set at 270 nm for monitoring the analyte. Using the retrograde method, at infusion concentrations of 1 microg/mL of cefamandole, the in vivo microdialysis recoveries were 55.44% for the rat blood (n = 6). Intra- and inter-assay accuracy and precision of the analyses were < or = 10% in the range of 0.1-10 microg/mL. Pharmacokinetic parameters were calculated from the recovery-corrected dialysate concentrations of cefamandole vs time data. The elimination half-life (t1/2,beta) was 21.6 +/- 1.6 min. The results suggest that the pharmacokinetics of unbound cefamandole in blood following cefamandole administration (50 mg/kg, i.v., n = 5) fit best to the two-compartmental model.  相似文献   

7.
《Analytical letters》2012,45(15):3213-3224
ABSTRACT

An in vivo microdialysis sampling method coupled to high-performance liquid chromatography has been applied for continuous monitoring of unbound ampicillin in rat blood. A microdialysis probe was inserted into the jugular vein/right atrium of Sprague-Dawley rats, and doses of 100 and 200 mg/kg ampicillin were then administered via the femoral vein. Dialysates were collected and directly injected into a liquid chromatographic system. Isocratic elution of ampicillin was achieved within 10 min using the liquid chromatographic system. The chromatographic mobile phase consisted of methanol-100 mM monosodium phosphoric acid (25:75, v/v, pH 5.5). The wavelength of the UV detector was set at 230 nm. The calibration curves from 0.25 to 50 μg/ml were linear with correlation coefficients of 0.995. The method provides a simple technique for rapid analysis of unbound ampicillin in rat blood for used in pharmacokinetic study.  相似文献   

8.
To characterize the pharmacokinetics of protein-free camptothecin in blood and brain we implanted microdialysis probes into the jugular vein and striatum of rats for unbound drug sampling and determination. Camptothecin (2 or 5 mg/kg, i.v., n=6) was then administered from the femoral vein, and microdialysates were collected from blood and brain of both sites and assayed by a validated microbore scale high-performance liquid chromatographic method. The mobile phase consisted of methanol–100 mM monosodium phosphoric acid (35:65, v/v, pH 2.5) with a flow-rate 0.05 ml/min. The fluorescence response for camptothecin was observed at excitation and emission wavelengths of 360 and 440 nm, respectively. Pharmacokinetic parameters were calculated from the corrected data for dialysate concentrations of camptothecin versus time. The results suggest that the pharmacokinetics of unbound camptothecin in blood and brain can be fitted best to a two- and one-compartment model, respectively. Camptothecin rapidly entered the extracellular fluid of brain striatum at 10 min following camptothecin administration.  相似文献   

9.
To investigate the pharmacokinetics of unbound ranitidine in rat blood and bile, multiple microdialysis probes coupled to a liquid chromatographic system were developed. This study design was parallel in the following groups: the control-group of six rats received ranitidine alone (10 and 30 mg/kg, i.v.), the treated-group rats were co-administered with ranitidine and cyclosporine (P-glycoprotein (P-gp) inhibitor) or quinidine (both organic cation transport (OCT) and P-gp inhibitors) in six individual rats. Microdialysis probes were inserted into the jugular vein and the bile duct for blood and bile fluids sampling, respectively. Ranitidine in the dialysate was separated by a reversed-phase C18 column (Zorbax, 150 mm x 4.6 mm i.d.; 5 microm) maintained at ambient temperature. Samples were eluted with a mobile phase containing acetonitrile-methanol-tetrahydrofuran-20 mM K2HPO4 (pH 7.0) (24:20:10:946, v/v), and the flow rate of the mobile phase was 1 ml/min. The optimal UV detection for ranitidine was set at wavelength 315 nm. Between 20 and 30 min after drug administration (10 or 30mg/kg), the ranitidine reached the maximum concentration in the bile. The bile-to-blood distribution ratio (AUC(bile)/AUC(blood)) was 9.8 +/- 1.9 and 13.9 +/- 3.8 at the dosages of 10 and 30 mg/kg, respectively. These studies indicate that ranitidine undergoes hepatobiliary excretion which against concentration gradient from bile-to-blood. In addition, the AUC of ranitidine in bile decreased in the treatment of cyclosporine or quinidine, which suggests that the hepatobiliary excretion of ranitidine was partially regulated by P-glycoprotein or organic cation transporter.  相似文献   

10.
We developed a sensitive microbore HPLC method coupled with an on-line microdialysis system to simultaneously measure endogenous 5-hydroxytryptamine (serotonin; 5-HT) and its major metabolite 5-hydroxyindoleacetic acid (5-HIAA) in the rat blood in vivo. A dialysis tube was placed in the right jugular vein. The validity of the procedure is demonstrated because analysis of the aggregating agents, collagen (I mg/kg) plus epinephrine (0.3 mg/kg) after intravenous injection, showed that they induced an increase in 5-HT and 5-HIAA levels in the jugular vein of the rat.  相似文献   

11.
Metronidazole is a synthetic nitroimidazole-derived antibacterial and antiprotozoal agent used for the treatment of infections involving gram-negative anaerobes. The aim of this study is to develop an in vivo microdialysis with microbore high-performance liquid chromatographic system for the pharmacokinetic study of metronidazole in rat blood, brain and bile. In addition, to investigate the disposition mechanism of metronidazole, the P-glycoprotein modulator and cytochrome P450 inhibitor were concomitantly administered. Separation of metronidazole from various biological fluids was applied to a microbore reversed-phase ODS 5 microm (150 x 1 mm I.D.) column. Its mobile phase consists of an acetonitrile-50 mM monosodium phosphate buffer (pH 3.0) containing 0.1% triethylamine (10:90, v/v) with a flow-rate of 0.05 ml/min. The UV detector wavelength was set at 317 nm. The results suggest that metronidazole penetrates the blood-brain barrier (BBB) and goes through hepatobiliary excretion. However, these pathways of BBB penetration and hepatobiliary excretion of metronidazole may not be related to the P-glycoprotein.  相似文献   

12.
To elucidate the disposition of nicotine in the brain is important because the neuropharmacological effects from nicotine exposure are centrally predominated. The aim of the present study was to develop a rapid and simple method for the simultaneous determination of unbound nicotine and its main metabolite, cotinine, in rat blood and brain tissue. We coupled a multiple sites microdialysis sampling technique with HPLC-UV system to characterize the pharmacokinetics of both nicotine and cotinine. Microdialysis probes were inserted into the jugular vein/right atrium and brain striatum of Sprague-Dawley rats, and nicotine (2 mg/kg, i.v.) was administered via the femoral vein. Dialysates were collected every 10 min and injected directly into a HPLC system. Both nicotine and cotinine were separated by a phenyl-hexyl column (150 mm x 4.6 mm) from dialysates within 12 min. The mobile phase consisted of an acetonitrile-methanol-20 mM monosodium phosphate buffer (55:45:900, v/v/v, pH adjusted to 5.1) with a flow-rate of 1 ml/min. The wavelength of the UV detector was set at 260 nm. The limit of quantification for nicotine and cotinine were 0.25 microg/ml and 0.05 microg/ml, respectively. Intra- and inter-day precision and accuracy of both measurements fell well within the predefined limits of acceptability. The blood and brain concentration-time profile of nicotine and cotinine suggests that nicotine is easily to get into the central nervous system and cotinine exhibits a long retention time and accumulates in blood.  相似文献   

13.
A reversed-phase high-performance liquid chromatography assay for mangiferin in rat plasma and urine was developed. Rutin was employed as an internal standard. The mobile phase consisted of acetonitrile-water (16:84, v/v) containing 3% acetic acid at a flow rate of 1 mL/min. Detection was at 257 and 365 nm for mangiferin in plasma and urine, respectively. The limit of quantitation (LOQ) of mangiferin was 0.6 microg/mL in plasma, and 0.48 microg/mL in urine. The standard curve was linear from 0.6 to 24 microg/mL in plasma, and 0.48 to 24 microg/mL in urine, both intra- and inter-day precision of the mangiferin were determined and their RSD did not exceed 10%. The method provides a technique for rapid analysis of mangiferin in rat plasma and urine, which can be used in pharmacokinetic studies.  相似文献   

14.
High-performance liquid chromatography coupled to microdialysis was used for the simultaneous determination of unbound berberine in rat blood, liver and bile for a pharmacokinetic study. Microdialysis probes were simultaneously inserted into the jugular vein toward the right atrium, the median lobe of the liver, and the bile duct of male Sprague-Dawley rats for biological fluid sampling after administration of berberine (10 mg/kg) through the femoral vein. Berberine and dialysates were separated using a Zorbax SB-phenyl column and a mobile phase comprised of acetonitrile-methanol-20 mM monosodium phosphate (pH 3.0) (35:20:45, v/v) together with 0.1 mM 1-octanesulfonic acid. The detection limit for berberine was 10 ng/ml. The concentration-response relationship was linear (r2 > 0.995) over the concentration range 0.05-50 microg/ml; intra-assay and inter-assay precision and accuracy for berberine fell within predefined limits. The disposition of berberine in the blood, liver and bile fluid suggests that berberine might be metabolized in the liver and undergo hepatobiliary excretion.  相似文献   

15.
A sensitive high-performance liquid chromatographic (HPLC) method for the quantitation of famotidine in human plasma is described. Clopamide was used as the internal standard. Plasma samples were extracted with diethyl ether to eliminate endogenous interferences. Plasma samples were then extracted at alkaline pH with ethyl acetate. Famotidine and the internal standard were readily extracted into the organic solvent. After evaporation of ethyl acetate, the residue was analysed by HPLC. The chromatographic separation was accomplished with an isocratic mobile phase consisting of acetonitrile-water (12:88, v/v) containing 20 mM disodium hydrogenphosphate and 50 mM sodium dodecyl sulphate, adjusted to pH 3. The HPLC microbore column was packed with 5 microns ODS Hypersil. Using ultraviolet detection at 267 nm, the detection limit for plasma famotidine was 5 ng/ml. The calibration curve was linear over the concentration range 5-500 ng/ml. The inter- and intra-assay coefficients of variation were found to be less than 10%. Applicability of the method was demonstrated by a bioavailability/pharmacokinetic study in normal volunteers who received 80 mg famotidine orally.  相似文献   

16.
As a prerequisite to the determination of pharmacokinetic parameters of icariin in rats, an HPLC method using UV detection was developed and validated. Icariin and the internal standard, quercetin, were extracted from plasma samples using ethyl acetate after acidification with 0.05 mol/L NaH2PO4 solution (pH 5.0). Chromatographic separation was achieved on an Agilent XDB Cls column (250 x 4.6 mm id, 5 microm) equipped with a Shim-pack GVP-ODS C18 guard column (10 x 4.6 mm id, 5 microm) using a mobile phase of ACN/water/acetic acid (31:69:0.4 v/v/v) at a flow rate of 1.0 mL/ min. Detection was at 277 nm. The calibration curve was linear from 0.05 to 100.0 microg/mL with 0.05 microg/mL as the lower LOQ (LLOQ) in plasma. The intra- and interday precisions in terms of RSD were lower than 5.7 and 7.8% in rat plasma, respectively. The accuracy in terms of relative error (RE) ranged from -1.6 to 3.2%. The extraction recoveries of icariin and quercetin were 87.6 and 80.1%, respectively. The main pharmacokinetic parameters for rats were determined after a single intravenous administration of 10 mg/kg icariin: t1/2, 0.562 +/- 0.200 h; AUC0-infinity, 8.73 +/- 2.23 microg x h/mL; CLToT, 20.10 +/- 5.80 L/kg x h; Vz, 1.037 +/- 0.631 L/kg; MRT0-infinity, 0.134 +/- 0.040 h; and Vss, 0.170 +/- 0.097 L/kg.  相似文献   

17.
To investigate the disposition of unbound cocaine in the rat blood, brain and bile, we demonstrate an in vivo multiple sampling microdialysis system coupled with liquid chromatography for cocaine assay and verified by tandem mass spectrometry. Three microdialysis probes were concurrently inserted into the jugular vein, bile duct and brain striatum of each anesthetized rat. After a period of 2 h post-surgical stabilization, cocaine (10 mg kg(-1)) was administered through the femoral vein. Separation of unbound cocaine from various biological fluids was applied to a reversed-phase C(18) column (250 x 4.6 mm I.D., 5 microm). The mobile phase consisted of acetonitrile--10 mm potassium dihydrogen phosphate buffer (25:75, v/v, pH 4.0) and 0.8% diethylamine at a flow rate of 1 mL min(-1). The UV detector wavelength was set at 235 nm. The results indicate that cocaine penetrates the blood--brain barrier with a rapid distribution. However, unbound cocaine in the bile dialysate was not detectable in the UV detection. We therefore use LC--tandem mass spectrometry to detect the bile fluid after cocaine administration (3 mg kg(-1), i.v.). The results indicate that cocaine goes through hepatobiliary excretion.  相似文献   

18.
A liquid chromatographic method coupled with microdialysis was used to determine the protein-unbound (-)-epigallocatechin-3-gallate (EGCG) in rat blood. EGCG and dialysates were separated using a Merck RP-18e column maintained at ambient temperature, and a mobile phase comprised of acetonitrile-10 mM monopotassium phosphate (pH 3.82) (20:80, v/v) with a flow rate of 1.0 ml/min. The UV detector wavelength was set at 206 nm. The detection limit for EGCG was 10 ng/ml. The concentration-response relationship was linear (r2 > 0.995) over a concentration range of 0.05-10 microg/ml; intra- and inter-assay precision and accuracy of EGCG fell within predefined limits. Pharmacokinetic parameters of EGCG were assessed using compartmental models. The disposition of EGCG in the rat blood suggests that EGCG was fitted by two-compartmental model. The distribution and elimination half-lives were 6 and 72 min respectively, after the dosage of 30 mg/kg.  相似文献   

19.
Daphnoretin (7-hydroxyl-6-methoxy-3,7'-dicoumaryl ether), isolated from Wikstronemia indica C.A. Mey. (Thymelaceae), has been reported to induce rabbit platelet aggregation through protein kinase C activation and anticancer activity. In this study, we developed an automated blood sampling system coupled to a simple and sensitive HPLC system to determine plasma concentration of daphnoretin in rats. This method was applied to investigate the pharmacokinetics of daphnoretin in a freely moving rat. Separation of daphnoretin in the rat plasma was achieved using a reversed-phase C18 column (250 mm x 4.6 mm, 5 microm) with a mobile phase of methanol-10 mM NaH2PO4 (adjusted to pH 3.0 with H3PO4) (55:45, v/v), and the flow rate of 1.0 ml/min. The UV detector was set at 345 nm. The automated blood sampling system (DR-II has been applied for blood sampling in a conscious and freely moving rat. The blood samples were centrifuged at 3000 x g for 10 min and the plasma samples were then deproteinized by acetonitrile containing an internal standard (khellin 1 microg/ml). After centrifugation (8000 x g for 10 min), the aliquot of supernatant was injected into the HPLC system for analysis. The concentration-response relationship from the present method indicated linearity over a concentration range of 0.05-1.00 and 1.00-100 microg/ml. Intra- and inter-assay precision and accuracy of daphnoretin fell well within the predefined limits of acceptability (< or = 15%). After daphnoretin (500 mg/kg) was given orally, the maximum concentration was 0.17 microg/ml at the time of 5 min. The oral bioavailability was about 0.15%.  相似文献   

20.
A reversed-phase high-performance liquid chromatographic (HPLC) assay was developed for the antitumor anthrapyrazole analogue, oxantrazole (OX), in rat whole blood and tissues. Blood samples were mixed with equal volumes of a 25% (w/v) aqueous solution of L-ascorbic acid, whereas tissue samples were homogenized with 1.5-3 volumes of an L-ascorbic acid-methanol-water (1:10:1, w/v/v) mixture to prevent oxidative degradation of OX. Samples were then treated with 60% (v/v) perchloric acid (25-30 microliters/ml of stabilized sample) to precipitate proteins, and centrifuged, with the resultant supernatants analyzed on HPLC utilizing a C8 column. The mobile phase for blood and urine samples consisted of 8% (v/v) glacial acetic acid, 13% (v/v) acetonitrile, 79% (v/v) water, 0.16% (w/v) sodium acetate, and 0.05% (w/v) L-ascorbic acid (final pH 2.7), and was pumped at 1.8 ml/min. Tissue samples were eluted at 2 ml/min with a mobile phase consisting of 8% (v/v) glacial acetic acid, 12% (v/v) acetonitrile, 80% (v/v) water, 0.16% (w/v) sodium acetate, and 0.0;5% (w/v) L-ascorbic acid. OX and internal standard were detected at 514 nm and had retention times of 2.3 and 3.1 min, respectively. The limit of quantitation of OX was 25-50 ng/g. Recovery of OX from biological samples ranged from 50 +/- 0.9% in spleen to 102.8 +/- 1.8% in RG-2 glioma. The analytical method was applied to a pharmacokinetic study in rats.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号