首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Pyrocatechol is immobilized on cellulose via ---NH---CH2---CH2---NH---SO2---C6H4---N=N--- linker and the resulting macromolecular chelator characterized by IR, TGA, CPMAS 13C NMR and elemental analyses. It has been used for enrichment of Cu(II), Zn(II), Fe(III), Ni(II), Co(II), Cd(II) and Pb(II) prior to their determination by flame atomic absorption spectrometry (FAAS). The pH ranges for quantitative sorption (98.0–99.4%) are 4.0–7.0, 5.0–6.0, 3.0–4.0, 5.0–7.0, 5.0–8.0, 7.0–8.0 and 4.0–5.0, respectively. The desorption was found quantitative with 0.5 mol dm−3 HCl/HNO3 (for Pb). The sorption capacity of the matrix for the seven metal ions has been found in the range 85.3–186.2 μmol g−1. The optimum flow rate of metal ion solution for quantitative sorption of metal onto pyrocatechol functionalized cellulose as determined by column method, is 2–6 cm3 min−1, whereas for desorption it is 2–4 cm3 min−1. The tolerance limits for NaCl, NaBr, NaI, NaNO3, Na2SO4, Na3PO4, humic acid, EDTA, ascorbic acid, citric acid, sodium tartrate, Ca(II) and Mg(II) in the sorption of all the seven metal ions are reported. Ascorbic acid is tolerable up to 0.8 mmol dm−3 with Cu and Pb where as sodium tartrate does not interfere up to 0.6 mmol dm−3 with Pb. There is no interference of NaBr, NaCl and NaNO3 up to a concentration of 0.5 mol dm−3, in the sorption of Cu(II), Cd(II) and Fe(III) on to the chelating cellulose matrix The preconcentration factors are between 75 and 300 and t1/2 values ≤5 min for all the metal ions. Simultaneous sorption of Cu, Zn, Ni and Co is possible at pH 5.0 if their total concentration does not exceed lowest sorption capacity. The present matrix coupled with FAAS has been used to enrich and determine the seven metal ions in river and tap water samples (relative standard deviation (R.S.D.) 1.05–7.20%) and synthetic certified water sample SLRS-4 (NRC, Canada) with R.S.D. 2.03%. The cobalt present in pharmaceutical vitamin tablets was also preconcentrated on the modified cellulose and determined by FAAS (R.S.D. 1.87%).  相似文献   

2.
Goswami A  Singh AK  Venkataramani B 《Talanta》2003,60(6):1141-1154
The silica gel modified with (3-aminopropyl-triethoxysilane) was reacted with 5-formyl-8-hydroxyquinoline (FHOQx) to anchor 8-quinolinol ligand on the silica gel. It was characterised with cross polarisation magic angle spinning (CPMAS) NMR and diffuse reflectance infrared Fourier transformation (DRIFT) spectroscopy and used for the preconcentration of Cu(II), Pb(II), Ni(II), Fe(III), Cd(II), Zn(II) and Co(II) prior to their determination by flame atomic absorption spectrometry. The surface area of the modified silica gel has been found to be 227 m2 g−1 and the two pKa values as 3.8 and 8.0. The optimum pH ranges for quantitative sorption are 4.0–7.0, 4.5–7.0, 3.0–6.0, 5.0–8.0, 5.0–8.0, 5.0–8.0 and 4.0–7.0 for Cu, Pb, Fe, Zn, Co, Ni and Cd, respectively. All the metals can be desorbed with 2.5 mol l−1 HCl or HNO3. The sorption capacity for these metal ions is in range of 92–448.0 μmol g−1 and follows the order Cd3, NaCl, NaBr, Na2SO4 and Na3PO4, glycine, sodium citrate, EDTA, humic acid and cations Ca(II), Mg(II), Mn(II) and Cr(III) in the sorption of all the seven metal ions are reported. The preconcentration factors are 150, 250, 200, 300, 250, 300 and 200 for Cd, Co, Zn, Cu, Pb, Fe and Ni, respectively and t1/2 values <1 min except for Ni. The 95% extraction by batch method takes ≤25 min. The simultaneous enrichment and determination of all the metals are possible if the total load of the metal ions is less than sorption capacity. In river water samples all these metal ions were enriched with the present ligand anchored silica gel and determined with flame atomic absorption spectrometer (R.S.D.≤6.4%). Cobalt contents of pharmaceutical samples (vitamin tablet) were preconcentrated with the present chelating silica gel and estimated by flame AAS, with R.S.D.1.4%. The results are in the good agreement with the certified value, 1.99 μg g−1 of the tablets. Iron and copper in certified reference materials (synthetic) SLRS-4 and SLEW-3 have been enriched with the modified silica gel and estimated with R.S.D.<5%.  相似文献   

3.
Determination of glyphosate by ion chromatography   总被引:4,自引:0,他引:4  
An ion chromatography system for the determination of glyphosate was described. Ion chromatograph was carried out by suppressed conductivity detection (DX-100). The eluent contained 9 mmol l−1 Na2CO3 and 4 mmol l−1 NaOH. The detection limit was 0.042 μg ml−1 (S/N=3). The relative standard deviation was 1.99% and the correlation coefficient of the calibration curve for area was 0.9995. The linear range was 0.042100 μg ml−1. Common inorganic ion and organic acids did not interfere. The recovery was 96.4103.2%. The method was simple, rapid, reliable and inexpensive.  相似文献   

4.
Kumar M  Rathore DP  Singh AK 《Talanta》2000,51(6):1187-1196
A stable chelating resin matrix was synthesized by covalently linking o-aminophenol (o-AP) with the benzene ring of the polystyrene–divinylbenzene resin, Amberlite XAD-2, through a –N=N– group. Elemental analyses, thermogravimetric analysis (TGA) and infrared spectra have characterized the resulting chelating resin. It has been used to preconcentrate Cu2+, Cd2+, Co2+, Ni2+, Zn2+ and Pb2+, prior to their determination by flame atomic absorption spectrometry. The optimum pH values for quantitative sorption of Cu, Cd, Co, Ni, Zn and Pb are 6.2–7.4, 5.6–7.2, 5.6–9.0, 6.0–9.0, 5.7–7.0 and 5.0–6.0, respectively. These metals are desorbed (recovery 91–98%) with 4 mol dm−3 HNO3. The sorption capacity of the resin is 3.37, 3.42, 3.29, 3.24, 2.94 and 3.32 mg of metal g−1 of resin, respectively, for Cu, Cd, Co, Ni, Zn and Pb. The effect of NaF, NaCl, NaNO3, Na2SO4, and Na3PO4 on the sorption of these metal ions has been investigated. These electrolytes are tolerable up to 0.01 mol dm−3 in case of all the metal ions, except Cl which is tolerable even up to 0.1 mol dm−3 for Zn and 1.0 mol dm−3 for Pb. The preconcentration factor for Cu, Cd, Co, Ni, Zn and Pb are 50, 50, 100, 65, 40 and 40 (concentration level 10–25 μg dm−3) respectively. Simultaneous enrichment of the six metals is possible. The method has been applied to determine Cu, Cd, Co, Ni, Zn and Pb content in well water samples (RSD≤8%).  相似文献   

5.
Matoso E  Kubota LT  Cadore S 《Talanta》2003,60(6):1105-1111
An analytical method using silica gel chemically modified with zirconium (IV) phosphate for preconcentration of lead and copper, in a column system, and their sequential determination by flame atomic absorption spectrometry (FAAS), was developed. Sample solutions are passed through a glass column packed with 100 mg of the sorbent material, at pH 4.5, and lead and copper are eluted with 1.0 mol l−1 HNO3 at a flow rate of 2.0 ml min−1. The extraction of copper is affected by Fe(II), Mn(II), Zn(II), Ni(II) and Co(II) while only Fe(II) interferes in the lead determination. These interferences may be overcome with an appropriate addition of a KI or NaF solution. An enrichment factor of 30 was obtained for both metals. While the limits of detection (3σ) were 6.1 and 1.1 μg l−1, for Pb and Cu, respectively, the limits of determination were 16.7 and 3.3 μg l−1. The precision expressed as relative standard deviation (R.S.D.) obtained for 3.3 μg l−1 of Cu and 16.7 μg l−1 of Pb were 4.3 and 4.7%, respectively, calculated from ten measurements. The proposed method was evaluated with reference material and was applied for the determination of lead and copper in industrial and river waters.  相似文献   

6.
A THGA graphite furnace with Zeeman background correction has been used to determine platinum content in copper ore and copper concentrate at the part per billion (ppb) concentration level. Two different procedures for the separation of trace platinum have been applied: (i) use of an ion exchange resin; and (ii) a two-stage method based on platinum separation on inorganic carriers. The influence of interfering elements in the matrix (Cu, Pb, Fe, Ti, V, Au, Pd, Ir, Rh and Al) has been examined using a graphite furnace. It was found that the presence of Cu (12.5–100 mg l−1), Pb (100–500 mg l−1), Fe (100–2000 mg l−1), Ti (25–100 mg l−1), V (25–100 mg l−1), Au (25–300 mg l−1), Pd (20–250 mg l−1), Ir (0.5–3.5 mg l−1) and Rh (0.025–1 mg l−1) in the samples analyzed has no effect on the platinum absorption signal when using a recommended temperature program (Tpyr=1300°C, Tat=2450°C). Spectral interference was observed, which was due to aluminum, as a result of the close neighborhood of the Pt 265.945-nm and Al 266.039-nm lines. This interference could not be eliminated by the Zeeman background correction.  相似文献   

7.
A continuous flow system for the determination of lead in home made spirituous beverages was developed. The determination was based on the formation of a neutral chelate of the element with ammonium pyrrolidine dithiocarbamate, its adsorption onto a minicolumn packed with sodium faujasite type Y synthetic zeolite, followed by elution with methyl isobutyl ketone and determination by flame atomic absorption spectrometry. Ethanol and copper interfere strongly in the determination and therefore, must be separated prior to the analysis. Copper is removed by precipitation with rubeanic acid, while ethanol is eliminated by rotaevaporation. Sample solutions containing Pb2+ in the concentration range from 5 to 120 μg l−1 at pH 2.5 could be analyzed, by using a preconcentration time of 3 min. Preconcentration factors from 80 to 140 were achieved for a sample volume of 6 ml and the detection limit varied from 1.4 to 3.5 μg l−1, depending on the matrix composition. The relative standard deviations for 60 μg l−1 Pb was 3.2% (n = 10) and the recovery of spikes (20, 40, 60 and 80 μg l−1) added to the samples was estimated within 92–105% range, suggesting that lead can be quantitatively determined in such samples. Determining lead in several samples by an alternative technique further checked the accuracy. Finally, the concentrations of Pb2+ determined in 28 samples of Venezuelan spirituous beverages were in 12.6–370.0 μg l−1 range, depending on the fermenting material based on different mixtures of agave, raw sugar cane and white sugar.  相似文献   

8.
The proposed method for cyanide determination at the ultratrace level by differential pulse voltammetry is based in the sensitivity enhancement obtained when both Cu(II) and EDTA are present in the background electrolyte. Comparison of the detection limits and linear dynamic ranges using the conventional borate (pH 9.75), and the proposed borate-EDTA–Cu(II) background electrolytes was carried out. Best results have been obtained with the addition of 0.5 mmol l−1 EDTA and 0.02 mmol l−1 of Cu(II), which allow a detection limit of 1.7 μg l−1 CN (65 nmol l−1 — absolute detection limit 34 ng) with a precision better than ±2% for a 40 μg l−1 level. Calibration range extended from detection limit up to 100 μg l−1. Cyclic voltammetry indicates that the measured cyanide peak is obtained when the electrogenerated CuCN adsorbed onto the hanging mercury drop electrode surface, is oxidised at positive going potential scan. The method has been successfully applied to various industrial waste waters such as metal-finishing waste waters, water/sand mixtures from cleaning processes of coke production, leachates from wastes obtained from electrolytic cells of aluminium production, and liquors from gold extraction industry. Results obtained by the proposed method showed good agreement with those obtained by the standard methods (ion-selective potentiometry and the spectrophotometric pyridine method).  相似文献   

9.
The use of ICP/AES for the determination of zinc, in low concentration levels, in matrices containing high levels of copper is difficult because copper interferes in the zinc main emission wavelength (213.856 nm). In the present work, a separation of zinc from copper matrices was possible, using the reaction of zinc(II) cation with 1-(2-tiazolylazo)-2-naphthol (TAN), in the pH range of 6.5–8.0, resulting in a stable red complex. Copper also reacts with TAN but its interference was avoided by the addition of ascorbic acid and thiosulphate in the reaction medium. In this way, the aqueous solution was passed through a SEP PAK C18 cartridge, in which the zinc(II)–TAN complex was quantitatively retained, but it did not occur with copper which passes through the cartridge, as [Cu2(S2O3)2]2−, with the aqueous solution. The cartridge was washed with water and the complex eluted with ethanol. Then, the alcohol was evaporated and the complex decomposed by nitric acid. It results in both zinc pre-concentration and separation from copper. The zinc quantification was carried out by ICP/AES at 213.856 nm. The relative standard deviations, for ten different aliquots, were 5.7% and the average recovery found for zinc was 96%, even when the concentration ratio Cu/Zn was up to 500/1 (mg l−1:mg l−1). Other metals, like nickel, for example, can react with TAN in the same way as zinc but they do not interfere in the emission wavelength 213.856 nm.  相似文献   

10.
A simple procedure was developed for the direct determination of As(III) and As(V) in water samples by flow injection hydride generation atomic absorption spectrometry (FI–HG–AAS), without pre-reduction of As(V). The flow injection system was operated in the merging zones configuration, where sample and NaBH4 are simultaneously injected into two carrier streams, HCl and H2O, respectively. Sample and reagent injected volumes were of 250 μl and flow rate of 3.6 ml min−1 for hydrochloric acid and de-ionised water. The NaBH4 concentration was maintained at 0.1% (w/v), it would be possible to perform arsine selective generation from As(III) and on-line arsine generation with 3.0% (w/v) NaBH4 to obtain total arsenic concentration. As(V) was calculated as the difference between total As and As(III). Both procedures were tolerant to potential interference. So, interference such as Fe(III), Cu(II), Ni(II), Sb(III), Sn(II) and Se(IV) could, at an As(III) level of 0.1 mg l−1, be tolerated at a weight excess of 5000, 5000, 500, 100, 10 and 5 times, respectively. With the proposed procedure, detection limits of 0.3 ng ml−1 for As(III) and 0.5 ng ml−1 for As(V) were achieved. The relative standard deviations were of 2.3% for 0.1 mg l−1 As(III) and 2.0% for 0.1 mg l−1 As(V). A sampling rate of about 120 determinations per hour was achieved, requiring 30 ml of NaBH4 and waste generation in order of 450 ml. The method was shown to be satisfactory for determination of traces arsenic in water samples. The assay of a certified drinking water sample was 81.7±1.7 μg l−1 (certified value 80.0±0.5 μg l−1).  相似文献   

11.
An atomic absorption spectrophotometric method for the determination of trace copper after adsorption of its 1-nitroso-2-naphthol-3,6-disulfonic acid chelate on Ambersorb 572 has been developed. This chelate is adsorbed on the adsorbent in the pH range 1–8. The copper chelate is eluted with 5 ml of 0.1 mol l−1 potassium cyanide and determined by flame atomic absorption spectrometry (FAAS). The selectivity of the proposed procedure was also evaluated. Results show that iron(III), zinc(II), manganese(II) and cobalt(II) at the 50 μg l−1 level and sodium(I), potassium(I), magnesium(II), calcium(II) and aluminium(III) at the 1000 μg l−1 level did not interfere. A high enrichment factor, 200, was obtained. The detection limit (3σ) of copper was 0.34 μg l−1. The precision of the method, evaluated by seven replicate analyses of solutions containing 5 μg of copper was satisfactory and the relative standard deviation was 1.7%. The adsorption of copper onto Ambersorb 572 can formally be described by a Langmuir equation with a maximum adsorption capacity of 14.3 mg g−1 and a binding constant of 0.00444 l mg−1. The accuracy of the method is confirmed by analysing tomatoes leaves (NIST 1573a) and lead base alloy (NBS 53e). The results demonstrated good agreement with the certified values. This procedure was applied to the determination of copper in waters (tap, river and thermal waters), aluminium foil and tea samples.  相似文献   

12.
An electrochemiluminescence (ECL) sensor with good long-term stability and fast response time has been developed. The sensor was based on the immobilization of tris(2,2′-bipyridyl)ruthenium(II) (Ru(bpy)32+) into the Eastman-AQ55D–silica composite thin films on a glassy carbon electrode. The ECL and electrochemistry of Ru(bpy)32+ immobilized in the composite thin films have been investigated, and the modified electrode was used for the ECL detection of oxalate, tripropylamine (TPA) and chlorpromazine (CPZ) in a flow injection analysis system and showed high sensitivity. Because of the strong electrostatic interaction and low hydrophobicity of Eastman-AQ55D, the sensor showed no loss of response over 2 months of dry storage. In use, the electrode showed only a 5% decrease in response over 100 potential cycles. The detection limit was 1 μmol l−1 for oxalate and 0.1 μmol l−1 for both TPA and CPZ (S/N=3), respectively. The linear range extended from 50 μmol l−1 to 5 mmol l−1 for oxalate, from 20 μmol l−1 to 1 mmol l−1 for TPA, and from 1 μmol l−1 to 200 μmol l−1 for CPZ.  相似文献   

13.
A simple and rapid flow injection (FI) method is reported for the determination of phosphate (as molybdate reactive P) in freshwaters based on luminol chemiluminescence (CL) detection. The molybdophosphoric heteropoly acid formed by phosphate and ammonium molybdate in acidic conditions generated chemiluminescence emission via the oxidation of luminol. The detection limit (3× standard deviation of blank) was 0.03 μg P l−1 (1.0 nM), with a sample throughput of 180 h−1. The calibration graph was linear over the range 0.032–3.26 μg P l−1 (r2=0.9880) with relative standard deviations (n=4) in the range 1.2–4.7%. Interfering cations (Ca(II), Mg(II), Ni(II), Zn(II), Cu(II), Co(II), Fe(II) and Fe(III)) were removed by passing the sample through an in-line iminodiacetate chelating column. Silicate interference (at 5 mg Si l−1) was effectively masked by the addition of tartaric acid and other common anions (Cl, SO42−, HCO3, NO3 and NO2) did not interfere at their maximum admissible concentrations in freshwaters. The method was applied to freshwater samples and the results (26.1±1.1–62.0±0.4 μg P l−1) were not significantly different (P=0.05) from results obtained using a segmented flow analyser method with spectrophotometric detection (24.4±4.45–84.0±16.0 μg P l−1).  相似文献   

14.
A field oriented and economical method of coprecipitation of trace elements like Al, Au, Bi, Cd, Co, Cu, Fe, Mo, Ni, Pb, Pd, Ti, V, W, Zn and REE has been developed. A novel reductant D-glucose, reduces KMnO4 in solution to form a precipitate of MnO2. Two liters of clear natural water sample is adjusted to pH 3.5–4.0, and is treated with 10 ml of 1% KMnO4 and 20 ml of 0.1% D-glucose. The sample is heated at a temperature of 75–80 °C, MnO2 is formed which coprecipitates the above trace elements. The precipitate is separated by filtration, dissolved in 2 ml of 50% HCl and 2 ml of 30% H2O2 and diluted to 25 ml for analysis using AAS and ICP-AES. The recoveries were found to be 96–105%. The preconcentration factor is 80. Limits of determination by the proposed method in natural waters are 1 μg l−1 for Al, Cd, Mo, V, W, Ti and Zn, 5 μg l−1 for Au, Bi, Co, Cu, Fe, Ni, Pb and Pd and 8 μg l−1 for REE. The RSD of the present procedure (n=5) is 8% at 5 μg l−1 level. Twenty water samples can be analyzed by an analyst in an 8-h day.  相似文献   

15.
Matos RC  Coelho EO  Souza CF  Guedes FA  Matos MA 《Talanta》2006,69(5):1208-1214
The importance of atmospheric hydrogen peroxide (H2O2) in the oxidation of SO2 and other compounds has been well established. A spectrophotometric method for the determination of hydrogen peroxide in rainwater is proposed. This method is based on selective oxidation of hydrogen peroxide using an on-line tubular reactor containing peroxidase immobilized on Amberlite IRA-743 resin. The hydrogen peroxide in the presence of phenol, 4-aminoantipyrine and peroxidase, produces a red compound (λ = 505 nm). Beer's law is obeyed in a concentration range of 1–100 μmol l−1 hydrogen peroxide with an excellent correlation coefficient (r = 0.9991), at pH 7.0, with a relative standard deviation (R.S.D.) <2%. The detection limit of the method is 0.7 μmol l−1 (4.8 ng of H2O2 in a 200 μl sample). Measurements of hydrogen peroxide in rain samples were carried out over the period from November 2003 to January 2005, in the central area of the Juiz de Fora city, Brazil. The concentration of H2O2 varied from values lower than the detection limit to 92.5 μmol l−1. The effects of the presence of nonseasalt (NSS) SO42−, NO3 and H+ in the concentration of hydrogen peroxide in the rainwater had been evaluated. The average concentrations of H2O2, NO3, NSS SO42− and SO42− are 23.4, 18.9, 7.9 and 10.3 μmol l−1, respectively. The pH values for 82% of the collected samples are greater than 5.0. The spectrophotometeric method developed in this work that uses enzyme immobilized on the resin ion-exchange compared with the amperometric method did not present any significant difference in the results.  相似文献   

16.
Morlay C  Cromer M  Mouginot Y  Vittori O 《Talanta》1999,48(5):679-1166
The cadmium (II) or lead (II) complex formation with two poly(acrylic acids) of high molecular weight (Mw=2.5×105 and 3×106) was investigated in dilute aqueous solution (NaNO3 0.1 mol l−1; 25°C). Potentiometric titrations were carried out to determine the stability constants of the MA and MA2 complex species formed. Bjerrum’s method, modified by Gregor et al. (J. Phys. Chem. 59 (1955) 34–39), for the study of polymeric acids was used. The results were compared to those previously obtained in the same conditions with copper (II) and nickel (II) . It appeared that the two polymers under study present similar binding properties and that the stability constants of the complex species formed increased in the following order, depending on the metal ion: Ni(II)β102 was found to be close to 7.0) and allowed the formation of the predominant PbA2 species in a quite large pH domain. Finally, the greater stability of PAA complexes compared to those of their monomeric analogs, glutaric and acetic acids, was confirmed.  相似文献   

17.
Voltammetric determination of synthetically prepared phytochelatins (γ-Glu-Cys)2Gly (PC2) and (γ-Glu-Cys)3Gly (PC3) has been studied using new type of copper solid amalgam electrode. The determination, based on the formation of cuprous complexes in buffer pH 8.1, is suitable for concentrations of PC in the range 10–100 nmol l−1. Reproducibility, employing electrochemical cleaning of the electrode surface, was statistically evaluated. The achieved limit of detection (2.1–2.6×10−9 mol l−1 for DCV measurement) together with the robust character of the electrode offer its use for detection of PCs in separated extracts of real samples.  相似文献   

18.
Using zinc hexamethylenedithiocarbamate (Zn(HMDC)2) and flame atomic absorption spectrometry (FAAS) and/or flow injection hydride generation atomic absorption spectrometry (FI-HGAAS), solvent extraction of As(III) from HCl and H2SO4 media into 2,6-dimethyl-4-heptanone (diisobutyl ketone, DIBK) was examined. Arsenic(III) was quantitatively extracted with 2.41×10−3 mol l−1 Zn(HMDC)2 from about 0.004 (pH 2.4) to 4 mol l−1 HCl and H2SO4 aqueous solutions. The logarithmic conditional extraction constant of As(HMDC)3 in the HCl–DIBK system was determined to be 8.3±0.7, by the measurement of the distribution ratios of Zn(II) and As(III). The effectiveness of the proposed extraction method was ascertained in the determination of As in geochemical standard reference materials supplied by the Geological Survey of Japan. Furthermore, the analysis of arsenic in procedural blanks was 0.083±0.003 μg l−1.  相似文献   

19.
The freezing point depression of cryolite (Na3AlF6) by the addition of Al2S3 and FeS was investigated. It was found that for contents of up to 10 wt.% Al2S3, it brings into the melt three new species. X-ray analysis of solidified melts of the system Na3AlF6–Al2S3 showed that it contained chiolite, Na5Al3F14 and Na2S. Chiolite originates from a reaction between Na3AlF6 and AlF3. This suggests that the system Na3AlF6–Al2S3 is a part of the reciprocal system NaF, AlF3//Na2S, Al2S3. The solubility of FeS in cryolite melt is so low that it cannot be determined by the thermal analysis. When FeO is added to the Na3AlF6–Al2S3 melt, Fe2+ cations and S2− anions react under the formation of solid FeS. A similar reaction was observed for Ni2+ and S2− ions.  相似文献   

20.
Bismuth as BiCl4 and BH4 ware successively retained in a column (150 mm × 4 mm, length × i.d.) packed with Amberlite IRA-410 (strong anion-exchange resin). This was followed by passage of an injected slug of hydrochloric acid resulting in bismuthine generation (BiH3). BiH3 was stripped from the eluent solution by the addition of a nitrogen flow and the bulk phases were separated in a gas–liquid separator. Finally, bismutine was atomized in a quartz tube for the subsequent detection of bismuth by atomic absorption spectrometry. Different halide complexes of bismuth (namely, BiBr4, BiI4 and BiCl4) were tested for its pre-concentration, being the chloride complexes which produced the best results. Therefore, a concentration of 0.3 mol l−1 of HCl was added to the samples and calibration solutions. A linear response was obtained between the detection limit (3σ) of 0.225 and 80 μg l−1. The R.S.D.% (n = 10) for a solution containing 50 μg l−1 of Bi was 0.85%. The tolerance of the system to interferences was evaluated by investigating the effect of the following ions: Cu2+, Co2+, Ni2+, Fe3+, Cd2+, Pb2+, Hg2+, Zn2+, and Mg2+. The most severe depression was caused by Hg2+, which at 60 mg l−1 caused a 5% depression on the signal. For the other cations, concentrations between 1000 and 10,000 mg l−1 could be tolerated. The system was applied to the determination of Bi in urine of patients under therapy with bismuth subcitrate. The recovery of spikes of 5 and 50 μg l−1 of Bi added to the samples prior to digestion with HNO3 and H2O2 was in satisfactory ranges from 95.0 to 101.0%. The concentrations of bismuth found in six selected samples using this procedure were in good agreement with those obtained by an alternative technique (ETAAS). Finally, the concentration of Bi determined in urine before and after 3 days of treatment were 1.94 ± 1.26 and 9.02 ± 5.82 μg l−1, respectively.  相似文献   