首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
A molecularly imprinted polymer has been synthesized for a selective on-line catechol extraction, followed by its spectrophotometric determination in guarana powder, mate tea and tap water samples. A clean-up column, containing a methacrylic polymer + C18 solid phase, was also used in order to enhance selectivity. The imprinted polymer was prepared by bulk polymerization using catechol as template and 4-vinylpyridine as the functional monomer. Permanganate solution was used as spectrophotometric reagent, where Mn(VII) was reduced to Mn(II) by catechol in an acid medium, causing color loss, which was monitored at 528 nm. Physical (extraction flow rate, elution flow rate, coil length) and chemical (nature and concentration of the eluent, potassium permanganate concentration) variables were optimized, and the selectivity was appraised using three molecules (4-chloro-2-methylphenol, 2-cresol, 2-methoxyphenol) similar to catechol. These molecules did not present interference in 1:8, 1:10 and 1:10 (catechol/concomitant) proportions, respectively. The analytical calibration curve ranged from 3.0 up to 100 μmol L− 1 (r > 0.999; seven concentrations levels, n = 3) and the limits of detection (LOD) and quantification (LOQ) were 0.8 and 2.7 μmol L− 1, respectively. Precision, expressed as RSD, was of 3.0% (20 μmol L− 1, n = 10), and the analytical frequency was 15 h− 1. Accuracy was checked by the HPLC technique and the results did not present significant difference at 95% confidence levels according to the t test.  相似文献   

2.
A new electroanalytical methodology was developed for the quantification of the phytohormone indole-3-acetic acid (IAA), using a graphite–polyurethane composite electrode (GPU) and the square wave voltammetry (SWV), in 0.1 mol L− 1 phosphoric acid solution (pH 1.6). Analytical curves were constructed under optimized conditions (f = 100 s− 1, a = 50 mV, Ei = 5 mV) and the reached detection and quantification limits were 26 μg L− 1 and 0.2 mg L− 1, respectively. The developed methodology is simple and accurate for the routine determination of IAA. In order to verify the application of the electroanalytical methodology in fortified soil samples without previous treatment, an IAA assay was performed without serious interferences of the soil constituents.  相似文献   

3.
Occurrence of ochratoxin A in Turkish wines   总被引:1,自引:0,他引:1  
I. Var  B. Kabak   《Microchemical Journal》2007,86(2):241-247
A total of 95 wine samples including 34 white, 10 rosé and 51 red wines originating from four different Turkish areas were analysed for ochratoxin A (OTA). An analytical method based on immunoaffinity column (IAC) for clean-up and high performance liquid chromatography with fluorescence detection (HPLC-FD) was used to determine OTA in wines. The limit of detection (LOD) was estimated as 0.006 ng ml− 1 for white wine and 0.010 ng ml− 1 for rosé and red wines. The limit of quantification (LOQ) was estimated as 0.020 ng ml− 1 in white wine and 0.030 ng ml− 1 in rosé and red wines. Recovery experiments were carried out with spiked samples in the range 0.1–1 ng ml− 1 of OTA. The average OTA recoveries from spiked white wine samples varied from 79.43% to 85.07%; while the mean recoveries for rosé and red wine samples were in the range of 77.48–83.96% and 76.61–83.55%, respectively. OTA was detected in 82 (86%) wine samples at levels of < 0.006–0.815 ng ml− 1, which were below the maximum allowable limit established by the European Community. The mean OTA concentration in red wines was slightly higher than in white and rosé wines. Furthermore, our data indicate that the geographic region of origin has strong influence on OTA level for white, rosé and red wines: wines originating from Thrace (n = 44, mean = 0.158 ng ml− 1) and Aegean (n = 28, mean = 0.060 ng ml− 1) regions of Turkey were more contaminated with OTA compared with wines originating from central (n = 15, mean = 0.027 ng ml−1) and east Anatolia (n = 8, mean = 0.027 ng ml− 1) areas. This study showed that the occurrence of OTA in Turkish wines is high, but at levels that probably leads to a non-significant human exposure to OTA by consumption of wines.  相似文献   

4.
Quantum dots (QDs) or semiconductor nanocrystals have been receiving great interest in the last few years. In this paper, L-cysteine-coated CdSe/CdS core-shell QDs (λem = 585 nm) have been prepared, which have excellent water-solubility. The full width at half maximum (FWHM) of the photoluminescence of these nanocrystals is very narrow (about 30 nm), and the quantum yield (QY) is 15% relative to Rhodamine 6G in ethanol (QY = 95%). With excess free L-cysteine in the solution, the fluorescence intensity of L-cysteine-coated CdSe/CdS QDs showed improved stability. It was found that the fluorescence of L-cysteine-capped CdSe/CdS QDs could be quenched only by copper (II) ions and was insensitive to other physiologically important cations, such as Ca2+, Mg2+, Zn2+, Al3+, Fe3+, Mn2+ and Ni2+ etc. Based on this finding, the quantitative analysis of Cu2+ with L-cysteine-capped CdSe/CdS QDs has been established. The linear range was from 1.0 × 10− 8 to 2.0 × 10− 7 mol L− 1 and the limit of detection (LOD) was 3.0 × 10− 9 mol L− 1 (S/N = 3). The proposed method has first been applied to the determination of Cu2+ in vegetable samples with recoveries of 99.6–105.8%.  相似文献   

5.
In-capillary derivatization and field-amplified sample injection (FASI) coupled to capillary zone electrophoresis (CZE) was evaluated for the analysis of metals (Co(II), Cu(II), Ni(II), and Fe(II)) using 2-(5-Nitro-2-Pyridylazo)-5-(N-Propyl-N-Sulfopropylamino)Phenol (Nitro-PAPS) as the derivatizing agent. For FASI, the optimum conditions were water as sample solvent, 1 s hydrodynamic injection (0.1 psi) of a water plug, 5 s of electrokinetic introduction (10 kV) of the sample. The in-capillary derivatization was successfully achieved with zone-passing strategy in order tandem injection of Nitro-PAPS reagent (0.5 psi, 7 s), a small water plug (0.1 psi, 1 s), and metal ion introduction (10 kV, 5 s). The solution of 45 mmol L− 1 borate pH 9.7 and 1.0 × 10− 5 mol L− 1 Nitro-PAPS containing 20% acetonitrile was used as the running buffer. The limit of detection obtained by the proposed method was lower than those from pre-capillary derivatization about 3–28 times. The recovery of the method was comparable to pre-capillary derivatization method. In-capillary derivatization-FASI-CZE was applied to analysis of metals in wine samples. The results were compared with those obtained by CZE with pre-capillary derivatization method and atomic absorption spectrometry (AAS).  相似文献   

6.
A flow system designed with solenoid valves is proposed for determination of weak acid dissociable cyanide, based on the reaction with o-phthalaldehyde (OPA) and glycine yielding a highly fluorescent isoindole derivative. The proposed procedure minimizes the main drawbacks related to the reference batch procedure, based on reaction with barbituric acid and pyridine followed by spectrophotometric detection, i.e., use of toxic reagents, high reagent consumption and waste generation, low sampling rate, and poor sensitivity. Retention of the sample zone was exploited to increase the conversion rate of the analyte with minimized sample dispersion. Linear response (r = 0.999) was observed for cyanide concentrations in the range 1–200 μg L−1, with a detection limit (99.7% confidence level) of 0.5 μg L−1 (19 nmol L−1). The sampling rate and coefficient of variation (n = 10) were estimated as 22 measurements per hour and 1.4%, respectively. The results of determination of weak acid dissociable cyanide in natural water samples were in agreement with those achieved by the batch reference procedure at the 95% confidence level. Additionally to the improvement in the analytical features in comparison with those of the flow system with continuous reagent addition (sensitivity and sampling rate 90 and 83% higher, respectively), the consumption of OPA was 230-fold lower.  相似文献   

7.
In this paper, a sensitive flow injection chemiluminescence system luminol–myoglobin was described for determining femtogram nitrite. Nitrite bound myoglobin producing the ferric heme nitrite complexes, which catalyzed the electron transfer of luminol to myoglobin leading to fast chemiluminescence. The chemiluminescence intensity in the presence of nitrite was remarkably enhanced compared with that in the absence of it. Under the optimum reaction conditions the chemiluminescence increment produced was proportional to the concentration of nitrite in the range of 0.05 pg ml− 1–1.0 ng ml− 1 (R2 = 0.9991), with a detection limit (3σ) of 20.0 fg ml− 1. At the flow rate of 2.0 ml min− 1, the whole process including sampling and washing could be completed in 0.5 min offering the sampling efficiency of 120 h− 1 accordingly, and the relative standard deviation (RSD) was less than 2.60% (n = 5). It was satisfactory for the application to determine nitrite in human urine samples, and the possible mechanism was proposed.  相似文献   

8.
Sample treatment procedures were evaluated for fractionation of phosphorous in plant materials (determination of organic and inorganic, soluble and insoluble fractions). The procedures aimed the conversion of different species into orthophosphate, minimizing time, reagent amounts and waste generation. A monosegmented flow system with multicommutation was developed for the spectrophotometric determination of orthophosphate by the molybdenum blue method. Linear response within 0.5 and 25.0 mg L− 1 P, detection limit of 24 μg L− 1 P (99.7% confidence level), coefficient of variation of 3.5% (n = 10) and sampling rate of 38 measurements per hour were estimated. Each determination consumes 5.0 mg ascorbic acid and 0.60 mg of ammonium molybdate. Total phosphorous determination can be carried out after microwave-assisted acid digestion by employing 100 mg of plant material and 500 μL of concentrated HNO3. Extraction of soluble phosphorous can be carried out with water by stirring for 10 min and organic soluble phosphorous can be determined either after microwave-assisted acid digestion or photodegradation in the presence of ammonium persulfate in acid medium. The results for the different fractions agreed with those obtained by ICP OES at the 95% confidence level.  相似文献   

9.
In the present paper we describe a robust and simple method to measure dissolved iron (DFe) concentrations in seawater down to <0.1 nmol L−1 level, by isotope dilution multiple collector inductively coupled plasma mass spectrometry (ID-MC-ICP-MS) using a 54Fe spike and measuring the 57Fe/54Fe ratio. The method provides for a pre-concentration step (100:1) by micro-columns filled with the resin NTA Superflow of 50 mL seawater samples acidified to pH 1.9. NTA Superflow is demonstrated to quantitatively extract Fe from acidified seawater samples at this pH. Blanks are kept low (grand mean 0.045 ± 0.020 nmol L−1, n = 21, 3× S.D. limit of detection per session 0.020–0.069 nmol L−1 range), as no buffer is required to adjust the sample pH for optimal extraction, and no other reagents are needed than ultrapure nitric acid, 12 mM H2O2, and acidified (pH 1.9) ultra-high purity (UHP) water. We measured SAFe (sampling and analysis of Fe) reference seawater samples Surface-1 (0.097 ± 0.043 nmol L−1) and Deep-2 (0.91 ± 0.17 nmol L−1) and obtained results that were in excellent agreement with their DFe consensus values: 0.118 ± 0.028 nmol L−1 (n = 7) for Surface-1 and 0.932 ± 0.059 nmol L−1 (n = 9) for Deep-2. We also present a vertical DFe profile from the western Weddell Sea collected during the Ice Station Polarstern (ISPOL) ice drift experiment (ANT XXII-2, RV Polarstern) in November 2004–January 2005. The profile shows near-surface DFe concentrations of 0.6 nmol L−1 and bottom water enrichment up to 23 nmol L−1 DFe.  相似文献   

10.
A novel sequential injection method for the determination of nitrite at nanomolar level in seawater samples has been developed. The pink azo compound was formed based on the Griess reaction and quantitatively adsorbed onto a Sep-Pak C18 cartridge. The enriched azo compound was rinsed with water and ethanol (28%, v/v) in turn, and then eluted with an eluent containing 26.6% (v/v) ethanol and 0.108 mol L−1 H2SO4. Finally the azo compound was measured using a spectrophotometer at 543 nm. Under the optimized conditions, the linear calibration ranges were 0.71–42.9 nmol L−1 for a 150-mL sample and 35.7–429 nmol L−1 for a 15-mL sample. The relative standard deviation of 8 measurements was 1.44% for 14.3 nmol L−1 nitrite. For the 150 mL sample, the detection limit was estimated to be 0.1 nmol L−1. The throughput of the method was about 4 samples per hour. The proposed method has been successfully applied to the in-field determination of nanomolar concentrations of nitrite in seawater.  相似文献   

11.
This work reports the evaluation of the combined use of Pd and HF as chemical modifiers for the direct determination of total chromium in waters derived from petroleum exploration employing electrothermal atomic absorption spectrometry (ET AAS). Such waters, usually called as produced waters, have complex composition presenting a number of organic and inorganic substances. When obtained from offshore operations they also present high salinity. In order establish conditions for chromium measurement pyrolysis and atomization curves were built up in different media and employing Pd and HF as chemical modifiers. Also, a detailed study about calibration strategy was performed. At best conditions, pyrolysis and atomization temperatures were 1200 °C and 2600 °C, respectively, and 10 μL of a 500 mg L− 1 Pd solution was added together with 10 μL of a 50% (v/v) HF solution on 20 μL of sample. Obtained results indicate that, in this kind of sample, chromium can be determined by standard addition method or employing external calibration with standard solutions prepared in 0.8 mol L− 1 NaCl medium. In order to evaluate the accuracy of the procedure, a recovery test was performed with seven spiked samples of produced waters. The detection limit, quantification limit and the relative standard deviation in 0.8 mol L− 1 NaCl were also calculated and the values found were 0.45 μg L− 1, 1.5 μg L− 1 and 6.0% (at 2.5 μg L− 1 level), respectively.  相似文献   

12.
The present work proposes a direct method based on slurry sampling for the determination of zinc and copper in human hair samples by multi-element sequential flame atomic absorption spectrometry. The slurries were prepared by cryogenic grinding and sonication of the samples. The optimization step was performed using univariate methodology and the factors studied were: nature and concentration of the acid solution, amount sample/slurry volume, sonication time, and particle size. The established experimental conditions are the use of a sample mass of 50 mg, 2 mol L− 1 nitric acid solution, sonication time of 20 min and slurry volume of 10 mL. Adopting the optimized conditions, this method allows the determination of zinc and copper with detection limits of 88.3 and 53.3 ng g− 1, respectively, and precision expressed as relative standard deviation (RSD) of 1.7% and 1.6% (both, n = 10) for contents of zinc and copper of 100.0 and 33.3 μg g− 1, respectively. The accuracy was checked and confirmed by analysis of two certified reference materials of human hair. The procedure was applied for the determination of zinc and copper in two human hair samples. The zinc and copper contents varied from 100.0 to 175.6 and from 3.2 to 32.8 μg g− 1, respectively. These samples were also analyzed after complete digestion in a closed system and determination by FAAS. The statistical comparison by t-test (95% confidence level) showed no significant difference between these results.  相似文献   

13.
A new system for on-line preconcentration of molybdenum by sorption on a minicolumn associated to inductively coupled plasma — optical emission spectrometry with ultrasonic nebulization was studied. It is based on the sorption of molybdenum on a column packed with immobilized baker's yeasts on controlled pore glass without further complexing reagent. The molybdenum preconcentrated by biosorption was subsequently eluted with hydrochloric acid. Considering a sample flow rate of 5.0 mL min− 1, 10 mL of sample was preconcentrated in 2 min achieving a sensitive total enhancement factor of 480-fold, and the detection limit (3 s) obtained was 21 ng L− 1. Additionally, the calculated precisions expressed as percent relative standard deviation (RSD%) was 1.9%.Satisfactory results were obtained for the determination of molybdenum in standard reference material NIST 1643e Trace Elements in Water and real water samples.  相似文献   

14.
Vapor generation and atomization conditions in a heated quartz tube to detect Ag, Cd, Co, Cu, Ni and Zn using High Resolution Continuum Source AAS (HRCSAAS), were optimized. Vapors were generated after mixing acidified solutions containing 8-hydroxiquinoline (oxine) with sodium tetrahydroborate. Afterwards, they were swept to the heated quartz cell by an argon flow.Reaction loop size and temperature of the quartz cell were optimized for each element. A temperature of 960 °C was selected as a compromise value to detect most of the metals. Afterwards, a Plackett–Burmann design was proposed to select which parameters were most important. Type of acid and its concentration were the most statistical significant variables. Optimum conditions for sequential detection of Cd, Cu, Ni and Zn were: 1 mg L 1 Co as catalyst, 250 mg L 1 oxine, 0.6 M nitric acid, 1.75% (w/w) sodium tetrahydroborate (prepared in 0.4 (w/v)% NaOH), a reaction loop of 250 µL, and a 25 L h 1 carrier Ar flow. Ag and Co were each detected in their own optimized conditions. Analytical performance of the system was evaluated in connection with a selected pixel number, and spectral correction was used to eliminate NO absorption bands interference in Zn detection. Detection limits were in the range of 1.5–18 μg L 1 for Ag, Cu, Cd and Zn, whereas sensitivity was worst for Co (169 μg L 1) and Ni (586 μg L 1). Atomization in a quartz cell of Co and Ni volatile species, generated by an addition of sodium tetrahydroborate to an acidified solution of the analytes, was reported for the first time in this paper. Precision expressed as RSD(%) had values lower than 10% except for Ni.  相似文献   

15.
Quercetin can effectively accumulate at multi-walled carbon nanotubes-paraffin oil paste electrodes (CNTPE) and cause a sensitive anodic peak at around 0.32 V (vs. SCE) in a 0.10 M phosphate buffer solution (pH = 4.0). Under optimized conditions, the anodic peak current is linear to quercetin concentration in the ranges of 2.0 × 10− 9−1.0 × 10− 7 M and 1.0 × 10− 7−2.0 × 10− 5 M, and the regression equations are ip (μA) = 0.0017 + 0.928c (μM, r = 0.999) and ip (μA) = 0.183 + 0.0731c (μM, r = 0.995), respectively. This paste electrode can be regenerated by repetitively cycling in a blank solution for about 2 min. A 1.0 × 10− 6 M quercetin solution is measured for 10 times using the same electrode regenerated after every determination, and the relative standard deviation of the peak current is 1.7%. The method has been applied to the determination of quercetin in hydrolysate product of rutin and the recovery is 99.2–102.6%. In comparison with graphite paste electrode, carbon nanotubes-nujol paste electrode and carbon nanotubes casting film modified glassy carbon electrode, the CNTPE gives higher ratio of signal to background current and better defined voltammetric peak.  相似文献   

16.
The N2 and H2 evolution, respectively, were monitored during deposition of Pd and Cu from electroless plating baths to obtain in-process control of the composition during preparation of 3–7 μm thick PdCu membranes on tubular ceramic substrates. Compositions estimated by gas evolution compare favorably to those measured in post-mortem XRD and EDS analyses, mostly differing by not more than 1 at.%. This result suggests that use of gas evolution measurements to enable in-process control of composition to within 1 at.% is feasible. Annealing experiments in an H2 atmosphere demonstrated that, at 893 K, only 48 h are needed to form a stoichiometrically homogeneous, 9.5 μm thick, face centered cubic (fcc) Pd63Cu37 membrane from sequentially deposited layers; at 723 K, the same transformation requires over 2 weeks. The appearance of transient body centered cubic (bcc) and fcc phases with lower Pd contents signaled compositional segregation in the initial stages of alloy formation at 723 and 773 K and could be a source of persistent stoichiometric heterogeneity particularly in bcc PdCu membranes. The H2 fluxes of fcc Pd58Cu42 and Pd70Cu30 membranes were JH2=(1.6±1.1) mol m−2 s−1 exp[(−24.8±0.4)kJ mol−1/RT] and JH2=(3.7±0.6) mol m−2 s−1 exp[(−21.3±1.0)kJ mol−1/RT], respectively, at 100 kPa H2 pressure difference.  相似文献   

17.
A spectrophotometric method for the determination of triclosan in personal care products was proposed. It was based on the reaction of sodium nitrite with p-sulfanilic acid in an acidic medium to form diazonium ion, with which triclosan further formed an azo compound in an alkaline medium. The resulting yellow colored product has a maximum absorption at 452 nm. A good linear relationship (r = 0.9999) was obtained in the range of 0–30 mg L−1 triclosan. A detection limit of 0.079 g L−1 was achieved and the relative standard deviation was 0.24% (n = 11) at 14 mg L−1 triclosan. The proposed method has been applied to the analyses of triclosan in several personal care products and the results were in good agreement with those obtained by high-performance liquid chromatography.  相似文献   

18.
The voltammetric behavior of 4-methylbenzelidene camphor (MBC) was studied by square wave voltammetry (SWV) using mercury electrode. The experimental condition that provided the highest peak current with the best reduction signal definition of MBC was found in Britton-Robinson buffer and cationic surfactants, cetyltrimethylammoniun bromide (CTABr). A single peak of MBC reduction was observed at − 1.21 V versus Ag/AgCl. The developed methodology was applied for determination of MBC in commercial sunscreen SPF 15, 20 and 30 and for the simultaneous determination when other protection agents were associated, such as benzophenone-3 (BENZO) and octyl methoxycinammate (OMC). Both methodologies had shown good determination values for the analyzed samples. The calculated detection limit was 2.99 × 10− 9 mol L− 1 and the quantification limit was 9.98 × 10− 9 mol L− 1.  相似文献   

19.
The objective of this study is to estimate the contribution of Na+ as a counterion in the formation of H-AOT&Na-AOT-based W/O microemulsions using aqueous NaOH solution by pyranine absorbance measurements. A mixture of an aqueous NaOH solution containing pyranine/H-AOT&Na-AOT/isooctane was emulsified by changing the mixing ratio of Na-AOT (XNa-AOT = 0–1) and the mole fraction of NaOH (XNaOH = [NaOH]/the AOT concentration in the water pool = 0–1). The phase behavior of the emulsified mixture was evaluated from the absorbance of pyranine at the isosbestic point and by visual observations. W/O microelumsions are formed at the mid-range of XNa-AOT, whereas the emulsified mixture separates into two phases at lower XNa-AOT and higher XNa-AOT. The two phase boundaries shift toward lower XNa-AOT as with increasing XNaOH. The phase behavior depends on the degree of screening of electrostatic repulsions between the polar headgroups of AOT by the Na+ counterion. Interestingly, nano-sized W/O microemulsions are formed without phase separation using a highly concentrated NaOH aqueous solution when the Na-AOT mixing ratio is appropriately adjusted. The phase behavior was plotted as XNaOH versus XNa-AOT, and the correlation equations for the two phase boundaries were obtained by fitting the points. The contribution of the Na+ counterion from NaOH to W/O microemulsion formation was estimated by the correlation equations. The absorbance of pyranine and the size of W/O microemulsions, as measured by DLS, were plotted as a function of XNa+=(x[Na+   from   NaOH]+[Na+   from   Na-AOT])/[AOT], in which x is the ratio contributed by NaOH. The absorbance and size correlates well with XNa+, indicating that XNa+ is a meaningful parameter for quantitatively estimating phase behavior and size variation.  相似文献   

20.
In the present work, a simple and sensitive preconcentration-microwave plasma torch-atomic emission spectrometric procedure was carried out for the determination of cobalt and nickel. The method was based upon a flow-injection system with on-line preconcentration of the metal ions on a minicolumn of a strong acid cation-exchange resin. The operation parameters including sample acidity, flow rate, loading time, and eluent concentration, flow rate were studied and optimized. Under the optimal experimental conditions the enrichment factors were calculated as 13.58 and 17.65 for cobalt and nickel, respectively. The relative standard deviations, 3.73% for cobalt and 4.23% for nickel (n = 7), and a sample throughput of 40 h− 1 were obtained. Furthermore, the limits of detection were shown to be 1.28 and 1.80 μg·L− 1 for cobalt and nickel, respectively. The method was applied to the determination of cobalt and nickel in tea samples and the accuracy was assessed through recovery experiments.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏