首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Stir bar sorptive extraction for trace analysis   总被引:1,自引:0,他引:1  
Stir bar sorptive extraction (SBSE) was introduced in 1999 as a solventless sample preparation method for the extraction and enrichment of organic compounds from aqueous matrices. The method is based on sorptive extraction, whereby the solutes are extracted into a polymer coating on a magnetic stirring rod. The extraction is controlled by the partitioning coefficient of the solutes between the polymer coating and the sample matrix and by the phase ratio between the polymer coating and the sample volume. For a polydimethylsiloxane coating and aqueous samples, this partitioning coefficient resembles the octanol-water partitioning coefficient. In comparison to solid phase micro-extraction, a larger amount of sorptive extraction phase is used and consequently extremely high sensitivities can be obtained as illustrated by several successful applications in trace analysis in environmental, food and biomedical fields. Initially SBSE was mostly used for the extraction of compounds from aqueous matrices. The technique has also been applied in headspace mode for liquid and solid samples and in passive air sampling mode. In this review article, the principles of stir bar sorptive extraction are described and an overview of SBSE applications is given.  相似文献   

2.
A method for the determination of stale-flavor carbonyl compounds including E-2-octenal, E-2-nonenal, E,Z-2,6-nonadienal and E,E-2,4-decadienal in beer was developed using stir bar sorptive extraction (SBSE) with in-situ derivatization followed by thermal desorption-GC-MS analysis. The derivatization conditions with O-(2,3,4,5,6-pentafluorobenzyl)hydroxylamine and the SBSE conditions--sampling mode, salt addition, sample volume, polydimethylsiloxane volume (sample/polydimethylsiloxane phase ratio) and extraction time--were examined. The method showed good linearity over the concentration range from 0.1 to 10 ng ml(-1) for all analytes and the correlation coefficients were higher than 0.9993. The limits of detection ranged from 0.021 to 0.032 ng ml(-1) for all analytes. The recoveries (98-101%) and precision (RSD 2.4-7.3%) of the method were examined by analyzing beer samples fortified at the 0.5-ng ml(-1) level. The method was successfully applied to low-level concentration samples.  相似文献   

3.
A novel extraction procedure for stir bar sorptive extraction (SBSE) termed sequential SBSE was developed. Compared to conventional SBSE, sequential SBSE provides more uniform enrichment over the entire polarity/volatility range for organic pollutants at ultra-trace levels in water. Sequential SBSE consists of a SBSE performed sequentially on a 5-mL sample first without modifier using one stir bar, then on the same sample after addition of 30% NaCl using a second stir bar. The first extraction with unmodified sample is mainly targeting solutes with high Kow (logKow>4.0), the second extraction with modified sample solution (containing 30% NaCl) is targeting solutes with low and medium Kow (logKow<4.0). After extraction the two stir bars are placed in a single glass desorption liner and are simultaneously desorbed. The desorbed compounds were analyzed by thermal desorption and gas chromatography-mass spectrometry (TD-GC-MS). Recovery of model compounds consisting of 80 pesticides (organochlorine, carbamate, organophosphorus, pyrethroid, and others) for sequential SBSE was evaluated as a function of logKow (1.70-8.35). The recovery using sequential SBSE was compared with those of conventional SBSE with or without salt addition (30% NaCl). The sequential approach provided very good recovery in the range of 82-113% for most of the solutes, and recovery less than 80% for only five solutes with low Kow (logKow<2.5), while conventional approaches (with or without salt addition) showed less than 80% recovery for 23 and 41 solutes, respectively. The method showed good linearity (r2>0.9900) and high sensitivity (limit of detection: <10ngL(-1)) for most of the model compounds even with the scan mode in the MS. The method was successfully applied to screening of pesticides at ngL(-1) level in river water samples.  相似文献   

4.
A method for the simultaneous measurement of trace amounts of phenolic xenoestrogens, such as 2,4-dichlorophenol (2,4-DCP), 4-tert-butyl-phenol (BP), 4-tert-octylphenol (OP), 4-nonylphenol (NP), pentachlorophenol (PCP) and bisphenol A (BPA), in water samples was developed using stir bar sorptive extraction (SBSE) with in situ derivatization followed by thermal desorption (TD)-gas chromatography-mass spectrometry (GC-MS) analysis. The conditions for derivatization with acetic acid anhydride were investigated. A polydimethylsiloxane (PDMS)-coated stir bar and derivatization reagents were added to 10 ml of water sample and stirring was commenced for 10-180 min at room temperature (25 degrees C) in a headspace vial. Then, the extract was analyzed by TD-GC-MS. The optimum time for SBSE with in situ derivatization was 90 min. The detection limits of 2,4-DCP, BP, OP, NP, PCP and BPA were 2, 1, 0.5, 5, 2 and 2 pg ml(-1), respectively. The method showed good linearity over the concentration ranges of 10, 5, 2, 20, 10 and 10-1000 pg ml(-1) for 2,4-DCP, BP, OP, NP, PCP and BPA, respectively, and the correlation coefficients were higher than 0.99. The average recoveries of those compounds in river water samples were equal to or higher than 93.9% (R.S.D. <7.2%) with correction using the added surrogate standards. This simple, accurate, sensitive and selective method can be used in the determination of trace amounts of phenolic xenoestrogens in river water samples.  相似文献   

5.
Stir bar sorptive extraction (SBSE) is a microextraction technique, introduced to overcome the problem of limited extraction capacity and fragile fiber coatings inherent in the solid phase microextraction technique. The major limitations of the SBSE technique are that only polydimethylsiloxane has been commercially available, this reduces its use to non-polar analytes, and its tedious reconstitution step which can lead to loss of analytes and introduction of impurities. The current trend has been aimed at the use of other materials, some of which are commercially available, such as restricted access materials, carbon adsorbents, molecularly imprinted polymers, ionic liquids, microporous monoliths, sol–gel prepared coatings and dual phase material. This has greatly helped in widening the applications of SBSE for pesticide analysis in fruits and vegetables and other matrices. The introduction of a thermal desorption unit which eliminates the reconstitution step of the stir bar in organic solvents before instrumental analysis has helped to automate the extraction method online with gas chromatography. This paper reviews the use of SBSE in pesticide residues analysis in fruits and vegetables, with a view on sample preparation steps, method optimization and validation of analytical figures of merit.  相似文献   

6.
A simple and sensitive method for the determination of polar aromatic amines (PAAs) was developed using stir bar sorptive extraction (SBSE) coupling to high-performance liquid chromatography. A hydrophilic poly(vinylimidazole-divinylbenzene) (VIDB) monolithic material was prepared and acted as SBSE coating. The influences of polymerization conditions for VIDB on the extraction efficiency were investigated using aniline and 2,4-dinitroaniline as detected solutes. To achieve optimum extraction performance for PAAs, several parameters including extraction and desorption time, desorption solvent, ionic strength and pH value of sample matrix were investigated. The results showed that under the optimized experimental conditions, the method showed good sensitivity and excellent recoveries, as well as advantages such as linearity, simplicity, low cost and high feasibility. The extraction performance of present method to the target compounds also compared with commercial SBSE which using polydimethylsiloxane as coating and other SBSE which based on monolithic materials. Finally, the proposed method was successfully applied to the determination of PAAs in lake and sea waters, and excellent recoveries of spiked target compounds in real samples were obtained.  相似文献   

7.
Trace and ultra-trace analysis can be difficult to achieve, especially for polar, more volatile, and/or thermally unstable analytes. A novel technique, coined ICE Concentration Linked with Extractive Stirrer (ICECLES), may help address this problem. The implementation of ICECLES described here combines stir bar sorptive extraction (SBSE) with freeze concentration (FC), where an aqueous solution is frozen during SBSE in order to concentrate analytes into a polydimethylsiloxane (PDMS) coated stir bar. Five test probe molecules with a range of log Kows (2-butanol, benzyl alcohol, benzaldehyde, dimethyl trisulfide and bromobenzene) were prepared from aqueous solutions using ICECLES. Thermal desorption gas–chromatography mass–spectrometry was then used to quantify these analytes. Parameters affecting the performance of ICECLES (e.g., freeze rate) were evaluated, with extraction at lower speeds resulting in higher extraction efficiencies, whereas the freeze rate and initial analyte concentration only had a minor effect. ICECLES produced much higher extraction efficiencies than SBSE alone, with signal enhancements of up to 474× SBSE. ICECLES also provided excellent reproducibility and lower LODs than SBSE for all compounds tested. ICECLES performed well when used to analyze multiple triazine pesticides and breakdown products in environmental surface waters. Overall, the ICECLES technique was excellent at preparing aqueous samples for trace analysis and shows promise as a novel analytical sample preparation technology.  相似文献   

8.
Stir bar sorptive extraction (SBSE) is an extraction technique for enrichment of volatile and semi-volatile organic compounds from aqueous and gaseous media. After exposure to a sample, the stir bar, which is covered in a layer of a polysiloxane is subsequently removed and the sorbed compounds are then either thermally desorbed, and analysed by GC-MS or desorbed by means of a liquid, for improved selectivity or for interfacing to an LC system.The technique has been applied successfully to trace analysis in environmental, biomedical and food applications. Applications of SBSE to environmental, foodstuffs and pharmaceutical and biomedical samples are given.  相似文献   

9.
A multiresidue method for screening endocrine-disrupting chemicals (EDCs) and pharmaceuticals in aqueous samples is presented. Four 10-mL aliquots of water were taken for stir bar sorptive extraction (SBSE) and they were treated in the following way. In sample one, in situ derivatization was performed with acetic acid anhydride to improve the extraction efficiencies and chromatographic analysis of phenolic compounds. For the same reasons, aliquot two was treated with ethyl chloroformate to improve amine and acid extraction and analysis, and aliquot three with tetraethylborate to enhance organotin compound extraction and analysis. Methanol was added to sample four to stop adsorption of apolar solutes on the wall. After SBSE, the four stir bars, together with a plug of glass wool impregnated with bis(trimethylylsilyl)trifluoroacetamide (BSTFA) to derivatize hydroxyl functionalities, were introduced into the same thermal desorption tube, heat-desorbed, and analyzed simultaneously by capillary GC/MS. The figures of merit of the method were evaluated with an EDC model mixture. In scan-mode MS, the limits of detection (LODs) were in the range 1–500 ng/L, while the LODs dropped by a factor of 50–100 when ion monitoring MS was applied to the targets. The performance of the method was illustrated by analysing some real-world water samples.  相似文献   

10.
A method for mercury analysis and speciation in drinking water was developed, which involved stir bar sorptive extraction (SBSE) with in situ propyl derivatization and thermal desorption (TD)-GC-MS. Ten millilitre of tap water or bottled water was used. After a stir bar, pH adjustment agent and derivatization reagent were added, SBSE was performed. Then, the stir bar was subjected to TD-GC-MS. The detection limits were 0.01 ng mL(-1) (ethylmercury; EtHg), 0.02 ng mL(-1) (methylmercury; MeHg), and 0.2 ng mL(-1) (Hg(II) and diethylmercury (DiEtHg)). The method showed good linearity and correlation coefficients. The average recoveries of mercury species (n=5) in water samples spiked with 0.5, 2.0, and 6.0 ng mL(-1) mercury species were 93.1-131.1% (RSD<11.5%), 90.1-106.4% (RSD<7.8%), and 94.2-109.6% (RSD<8.8%), respectively. The method enables the precise determination of standards and can be applied to the determination of mercury species in water samples.  相似文献   

11.
搅拌棒吸附萃取涂层研制进展   总被引:2,自引:0,他引:2  
搅拌棒吸附萃取(SBSE)是20世纪90年代末发展起来的一种新型无溶剂样品前处理技术,具有固定相体积大、萃取容量高、无需外加搅拌子、可避免竞争性吸附、能在自身搅拌的同时实现萃取富集等优点,已广泛应用于环境、食品和生物等复杂样品中目标物质的痕量分析。涂层是SBSE技术的核心,决定了萃取选择性和容量。本文简要介绍了SBSE涂层的萃取原理、萃取解吸模式及其影响因素,重点阐述了近年SBSE涂层制备技术与方法,探讨了SBSE涂层发展中的不足,并展望了其发展趋势。  相似文献   

12.

Stir bar sorptive extraction (SBSE) is an extraction technique for enrichment of volatile and semi-volatile organic compounds from aqueous and gaseous media. After exposure to a sample, the stir bar, which is covered in a layer of a polysiloxane is subsequently removed and the sorbed compounds are then either thermally desorbed, and analysed by GC-MS or desorbed by means of a liquid, for improved selectivity or for interfacing to an LC system.The technique has been applied successfully to trace analysis in environmental, biomedical and food applications. Applications of SBSE to environmental, foodstuffs and pharmaceutical and biomedical samples are given.

  相似文献   

13.
A simple method is described for the measurement of testosterone (T) and epitestosterone (ET) in human urine samples. The deconjugated steroids were extracted directly from the samples by stir bar sorptive extraction (SBSE) and derivatized in situ on the stir bar by headspace acylation prior to thermal desorption and GC/MS. Extraction and derivatization parameters, namely salt addition, temperature, and time, were optimized to improve the recovery of T and ET by SBSE. The limits of quantification (S/N 10) were 0.9 ng/mL for T and 2.8 ng/mL for ET. Quantification of the steroids in urine samples was performed using standard addition to avoid the influence of matrix effects. The method was applied for the measurement of urinary T and ET in a group of healthy volunteers and HIV+ patients. Decreased levels of T were detected in the HIV+ group, whereas the excretion of ET was comparable for the two groups. Further clinical research is required to elucidate the biomarker significance of the T/ET ratio in HIV infection.  相似文献   

14.
A review with 75 references is presented that deals with the reported methods for analysis of some important central nervous system (CNS) drugs in biological fluids utilizing stir bar sorptive extraction (SBSE) technique covering the years from 2000 to 2008. The theoretical aspects of SBSE, as well as an significant number of applications have been published, showing the advantages of this technique over the classical extraction techniques (liquid–liquid extraction (LLE) and solid-phase extraction (SFE). In this review, recent SBSE developments and a focus on the development of new instrumental approaches and sorbent phases are presented.  相似文献   

15.
Stir bar sorptive extraction (SBSE) in combination with thermodesorption-gas chromatography-mass spectrometry (TD-GC-MS) was applied for the determination of eight insect repellents and synergists in water samples. The stir bar coated with polydimethylsiloxane (PDMS) was added to 20 mL of water sample with 4 g NaCl and stirred at 1000 rpm for 180 min. Then, the stir bar was subjected to TD-GC-MS. SBSE parameters (ionic strength, presence of organic solvent and time) were optimised. Blank contamination and carryover problems were also studied. The method affords detection limits between 0.5 and 30 ng/L, except for dimethyl phthalate (DMP) (150 ng/L) due to blank contamination problems. It shows good linearity with correlation coefficients over 0.997 and reproducibility (RSD) below 20%. The extraction efficiencies were between 29% for DMP and 80% for di-n-propyl isocinchomeronate (R-326). The feasibility of the method was tested by analysing real samples such as lake water, river water and wastewater.  相似文献   

16.
As a crucial step in qualitative and quantitative analysis, sample pretreatment is commonly used to isolate the target analytes, concentrate them, or convert them into the forms tailored to the instrumental analysis. In recent years, there has been a trend for sample pretreatment techniques to become more miniaturized and more environmentally friendly. Stir bar sorptive extraction (SBSE), which was developed in 1999, is such an environmentally friendly microextraction technique. Compared with other microextraction techniques, including solid phase microextraction and liquid phase microextraction, SBSE provides a higher extraction efficiency and better reproducibility owing to the much greater amount of the extraction phase, and no special skills are required. However, there are some problems associated with SBSE, such as the limited applicable coatings, coating abrasion of the laboratory-made stir bar, and the difficulty in automation, which restrict the further improvement and application of SBSE. This review focuses on the development of SBSE in the past decade, in terms of coating preparation, automated systems, novel extraction modes, its use with various instruments, and applications in food, environmental, and biological samples.
Figure
Recent development of stir bar sorptive extraction.  相似文献   

17.
A biocompatible stir bar sorptive extraction (SBSE) device was prepared using an alkyl-diol-silica (ADS) restricted access material (RAM) as the SBSE coating. The RAM-SBSE bar was able to simultaneously fractionate the protein component from a biological sample, while directly extracting caffeine and its metabolites, overcoming the present disadvantages of direct sampling in biological matrices by SBSE, such as fouling of the extraction coating by proteins. Desorption of the analytes was performed by stirring the bar in a water/ACN mixture (3/1, v/v) and subsequently reconcentrating the sample solution in water to enable HPLC-UV analysis to be performed. The limit of detection, based on a signal to noise ratio of 3, for caffeine was 25 ng/mL in plasma. The method was confirmed to be linear over the range of 0.5-100 microg/mL of caffeine with an average linear coefficient (R2) value of 0.9981. The injection repeatability and intra-assay precision of the method were evaluated over ten injections, resulting in a %RSD of approximately 8%. The RAM-SBSE device was robust (>50 extraction in plasma without significant signal loss) and simple to use, providing many direct extractions and subsequent determination of caffeine and its metabolites in biological fluids. In contrast to existing sample preparation methods for the analysis of caffeine and selected metabolites in biological fluids, this feasibility study using a biocompatible SBSE approach was advantageous in terms of simplifying the sample preparation procedures.  相似文献   

18.
A new polymeric coating consisting of a dual-phase, polydimethylsiloxane (PDMS) and polypyrrole (PPY) was developed for the stir bar sorptive extraction (SBSE) of antidepressants (mirtazapine, citalopram, paroxetine, duloxetine, fluoxetine and sertraline) from plasma samples, followed by liquid chromatography analysis (SBSE/LC-UV). The extractions were based on both adsorption (PPY) and sorption (PDMS) mechanisms. SBSE variables, such as extraction time, temperature, pH of the matrix, and desorption time were optimized, in order to achieve suitable analytical sensitivity in a short time period. The PDMS/PPY coated stir bar showed high extraction efficiency (sensitivity and selectivity) toward the target analytes. The quantification limits (LOQ) of the SBSE/LC-UV method ranged from 20 ng mL−1 to 50 ng mL−1, and the linear range was from LOQ to 500 ng mL−1, with a determination coefficient higher than 0.99. The inter-day precision of the SBSE/LC-UV method presented a variation coefficient lower than 15%. The efficiency of the SBSE/LC-UV method was proved by analysis of plasma samples from elderly depressed patients.  相似文献   

19.
A method for the determination of ultra-trace amounts of organochlorine pesticides (OCPs) in river water was developed by using stir bar sorptive extraction (SBSE) followed by thermal desorption and comprehensive two-dimensional gas chromatography coupled to high-resolution time-of-flight mass spectrometry (SBSE-TD-GC×GC-HRTOF-MS). SBSE conditions such as extraction time profiles, phase ratio (β: sample volume/polydimethylsiloxane (PDMS) volume), and modifier addition, were examined. Fifty milli-liter sample including 10% acetone was extracted for 3 h using stir bars with a length of 20 mm and coated with a 0.5 mm layer of PDMS (PDMS volume, 47 μL). The stir bar was thermally desorbed and subsequently analyzed by GC×GC-HRTOF-MS. The method showed good linearity over the concentration range from 50 to 1000 pg L(-1) or 2000 pg L(-1) for all analytes, and the correlation coefficients (r(2)) were greater than 0.9903 (except for β-HCH, r(2)=0.9870). The limit of detection (LOD) ranged from 10 to 44 pg L(-1). The method was successfully applied to the determination of 16 OCPs at pg L(-1) to ng L(-1) in river water. The results agree fairly well with the values obtained by a conventional liquid-liquid extraction (LLE)-GC-HRMS (selected ion monitoring: SIM) method using large sample volume (20 L). The method also allows screening of non-target compounds, e.g. pesticides and their degradation products, polyaromatic hydrocarbons (PAHs), polychlorinated biphenyls (PCBs), and pharmaceuticals and personal care products (PPCPs) and metabolites in the same river water sample, by using full spectrum acquisition with accurate mass in GC×GC.  相似文献   

20.
A simple and highly sensitive method called stir bar sorptive extraction (SBSE) and thermal desorption (TD)-gas chromatography-mass spectrometry (GC-MS), which is used for the determination of trace amounts of 5-chloro-2-(2,4-dichlorophenoxy)phenol (triclosan) in river water samples, is described. A stir bar coated with polydimethylsiloxane (PDMS) is added to a 10mL water sample and stirring is carried out for 120min at room temperature (25 degrees C) in a vial. Then, the PDMS stir bar is subjected to TD-GC-MS. The detection limit of triclosan is 5ngL(-1) (ppt). The method shows linearity over the calibration range (0.02-20mugL(-1)) and the correlation coefficient is higher than 0.997 for triclosan standard solution. The recovery of triclosan in river water samples ranges from 91.9 to 108.3% (RSD: 4.0-7.0%). This simple, accurate, sensitive, and selective analytical method may be used in the determination of trace amounts of triclosan in river water samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号