首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Lu M  Zhang L  Qiu B  Feng Q  Xia S  Chen G 《Journal of chromatography. A》2008,1193(1-2):156-163
A new method for rapid separation and sensitive detection of beta-blockers by pressure-assisted capillary electrochromatography (pCEC) with electrospray ionization mass spectrometry (ESI-MS) using silica-based monolithic column was studied in this paper. The proposed method has been confirmed to be very powerful since the fast mass transfer property and good permeability of silica monolithic column was used in this pCEC-ESI-MS system. In this work, a silica monolithic column was prepared with sol-gel method for simultaneous fast separation of beta-blockers. Furthermore, in order to obtain the highly selective and sensitive result of pCEC-ESI-MS, both the CEC separation and MS detection parameters were optimized in detail. Under the optimized conditions, namely 80% acetonitrile and 20% 20 mmol/L ammonium acetate (pH 6.0) as the mobile phase, 20 kV and 8 bar as the separation voltage and the assisted pressure, isopropanol/water (1:1, v/v) containing 7.5 mmol/L acetic acid as the sheath liquid, and 3 microL/min as the flow rate of sheath liquid, seven beta-blockers were well separated within 11 min with detection limits in the range of 0.15-0.80 ng/mL (defined as S/N=3). The recoveries of spiked urine samples of these beta-blockers were between 86.3 and 103% with the RSDs lower than 8.0%. The real samples from some male volunteers were successfully analyzed and confirmed with the proposed method. Comparing with GC-MS or LC-MS, the new method has some superiority (such as fast analysis capacity and simple pretreatment) in clinical practice and doping control.  相似文献   

2.
A pressure‐assisted CEC with ESI‐MS based on poly(1‐hexadecene‐co‐trimethylolpropane trimethacrylate) monolithic column for rapid analysis of two β2‐agonists and three narcotics was established in this article. After the organic polymer‐based monolithic column was prepared by an in‐situ polymerization procedure, a systematic investigation of the pressure‐assisted CEC separation and ESI‐MS detection parameters was performed. Baseline separation of the studied analytes could be obtained using the solution containing 75% ACN v/v and 20 mmol/L ammonium acetate with pH 8.0 as running buffer, when applying separation voltage of 20 kV and assisted pressure of 5 bar. Under the optimized conditions, two β2‐agonists and three narcotics could be completely resolved and accurately determined within 15 min. Finally, the proposed method was successfully used for real urine samples detection.  相似文献   

3.
李新燕  王彦  谷雪  陈妍  阎超 《色谱》2010,28(3):231-235
以甲基丙烯酸丁酯(BMA)和3-[N,N-二甲基-[2-(2-甲基丙-2-烯酰氧基)乙基]铵]丙烷-1-磺酸内盐(SPE)为单体,制备了新型的亲水作用毛细管整体柱,并通过三聚氰胺在此柱上的保留行为证明其具有亲水性。以加压毛细管电色谱(pCEC)技术为平台,优化了整体柱基于亲水作用分离分析奶制品中三聚氰胺的色谱条件。当流动相中乙腈与10 mmol/L磷酸盐缓冲液的体积比为80:20, pH为3.0,电压为3 kV,检测波长为215 nm时,三聚氰胺能获得很好的分离。方法学考察结果表明,合成的亲水整体柱具有良好的重现性和渗透性,建立的pCEC分析方法的检出限为0.05 mg/L。该方法简单方便,回收率较高,而且流动相中无需添加离子对试剂,适合于奶制品中三聚氰胺的定量测定。  相似文献   

4.
High-efficiency peptide analysis using multimode pressure-assisted capillary electrochromatography/capillary electrophoresis (pCEC/pCE) monolithic polymeric columns and the separation of model peptide mixtures and protein digests by isocratic and gradient elution under an applied electric field with UV and electrospray ionization-mass spectrometry (ESI-MS) detection is demonstrated. Capillary multipurpose columns were prepared in silanized fused-silica capillaries of 50, 75, and 100 microm inner diameters by thermally induced in situ copolymerization of methacrylic monomers in the presence of n-propanol and formamide as porogens and azobisisobutyronitrile as initiator. N-Ethylbutylamine was used to modify the chromatographic surface of the monolith from neutral to cationic. Monolithic columns were termed as multipurpose or multimode columns because they showed mixed modes of separation mechanisms under different conditions. Anion-exchange separation ability in the liquid chromatography (LC) mode can be determined by the cationic chromatographic surface of the monolith. At acidic pH and high voltage across the column, the monolithic stationary phase provided conditions for predominantly capillary electrophoretic migration of peptides. At basic pH and electric field across the column, enhanced chromatographic retention of peptides on monolithic capillary column made CEC mechanisms of migration responsible for separation. The role of pressure, ionic strength, pH, and organic content of the mobile phase on chromatographic performance was investigated. High efficiencies (exceeding 300 000 plates/m) of the monolithic columns for peptide separations are shown using volatile and nonvolatile, acidic and basic buffers. Good reproducibility and robustness of isocratic and gradient elution pressure-assisted CEC/CE separations were achieved for both UV and ESI-MS detection. Manipulation of the electric field and gradient conditions allowed high-throughput analysis of complex peptide mixtures. A simple design of sheathless electrospray emitter provided effective and robust low dead volume interfacing of monolithic multimode columns with ESI-MS. Gradient elution pressure-assisted mixed-mode separation CE/CEC-ESI-MS mass fingerprinting and data-dependent pCE/pCEC-ESI-MS/MS analysis of a bovine serum albumin (BSA) tryptic digest in less than 5 min yielding high sequence coverage (73%) demonstrated the potential of the method.  相似文献   

5.
陈巧梅  柳青  申琳  薛芸  王彦  阎超 《色谱》2018,36(4):388-394
采用改良Stöber法制备420 nm亚微米单分散二氧化硅微球,采用C18硅烷化修饰后装填成毛细管色谱柱。采用该色谱柱,在加压毛细管电色谱平台上成功地实现了3对手性三唑类农药烯效唑、烯唑醇和丙环唑的同时拆分和分离。考察了各因素对手性分离效果的影响,优化后的色谱条件为:流动相为乙腈-20 mmol/L磷酸盐缓冲液(pH=6.8)(45:55,v/v),其中缓冲液中含20 mmol/L羟丙基-γ-环糊精(HP-γ-CD);泵流速为0.04 mL/min;施加电压-9.4 kV;检测波长220 nm。在上述条件下,烯效唑、烯唑醇和丙环唑3种对映体同时得到拆分和分离,相邻两峰之间的分离度依次为4.20、12.9、4.41、4.09、1.70,分离时间仅为12 min,柱效最高达到310000 plates/m。该研究为手性三唑类农药的同时分离提供了新的分离分析思路。  相似文献   

6.
孙艺梦  于泓 《色谱》2013,31(10):969-973
建立了快速分析无紫外吸收的N-甲基,丙基吗啉阳离子的离子对色谱-间接紫外检测法。采用反相C18硅胶整体柱,以背景紫外吸收试剂-离子对试剂-有机溶剂为流动相。研究了背景紫外吸收试剂、检测波长、离子对试剂、有机溶剂、柱温、流速对吗啉阳离子测定的影响。最佳色谱条件为:(0.5 mmol/L对氨基苯酚盐酸盐-0.1 mmol/L庚烷磺酸钠)溶液-甲醇(9:1, v/v)为流动相,检测波长230 nm,柱温30 ℃,流速1.0 mL/min。在此条件下,N-甲基,丙基吗啉阳离子的保留时间为2.966 min,检出限为0.07 mg/L(S/N=3),峰面积的相对标准偏差为2.1%(n=5),保留时间的相对标准偏差为0.02%(n=5)。将此方法用于分析实验室合成的N-甲基,丙基吗啉离子液体,加标回收率为98.8%。结果表明本方法简便、快速。  相似文献   

7.
Wu X  Wang L  Xie Z  Lu J  Yan C  Yang P  Chen G 《Electrophoresis》2006,27(4):768-777
An isocratic elution pressurized CEC (pCEC) system was used to separate and determine ten carbamate insecticides. It was found that introduction of the electrical field, supplementary pressure, and SDS in the proposed method greatly improved the speed, column efficiency, selectivity, and repeatability for separation and determination of carbamates. On a capillary column of 75 microm ID packed with 3 microm octadecyl silica, baseline separation and detection of ten analytes was performed by using a mobile phase consisting of 30% v/v ACN and 70% v/v of 5 mmol/L ammonium acetate (pH 6.5) containing 1 mmol/L SDS and 0.01% triethylamine (TEA). Under the optimum conditions ten carbamate insecticides could be completely separated within 20 min. For the real vegetable samples, an SPE procedure for the cleanup of matrices was carried out prior to pCEC analysis. The detection limits of 0.05-1.6 mg/kg for ten carbamates and mean recoveries of 51.3-109.2% for eight kinds of vegetable samples at different concentrations of carbamates with RSD less than 11.4% were obtained, respectively. The proposed method has been proved to be effective in the rapid analysis of carbamate residues in vegetables.  相似文献   

8.
A system enabling coupling of pressurized capillary electrochromatography (pCEC) with off-column amperometric detection (AD) is reported in which conduction of the current in pCEC was achieved through a cellulose acetate-coated porous polymer joint, and the effect of the high-voltage field applied to pCEC for AD was also eliminated. Effects of supplementary pressure on the porous polymer joint and the effects on AD of capillary columns of different i.d. were investigated. The performance of the pCEC–AD system with the porous polymer joint was evaluated with phenol and hydroquinone using sulfonated stearyl methacrylate monolithic columns. The separation efficiency of the column in pCEC–AD, using the proposed off-column detection with the cellulose acetate membrane joint, was comparable with that of pCEC–UV using on-column detection. Compared with end-column detection using a 50 μm i.d. capillary column without a joint, a higher signal-to-noise ratio was achieved, even using a 100 μm i.d. capillary column with a joint. Successful separation and detection of dopamine and epinephrine were also achieved by use of this system.  相似文献   

9.
Ye F  Xie Z  Wong KY 《Electrophoresis》2006,27(17):3373-3380
A silica-based monolithic column as polar stationary phase is proposed for pressurized CEC (pCEC). The monolithic silica matrix from a sol-gel process was chemically modified by 3-aminopropyltrimethoxysilane to produce a column for hydrophilic interaction applications. The amino groups on the surface of the polar stationary phase generated anodic EOF under acidic conditions and served at the same time as a weak anion-exchanger. The anion solutes such as nucleotides were separated by the mixed mode mechanism, which comprised hydrophilic interaction, weak anion-exchange, and electrophoresis. The influences of buffer concentration and organic modifier content on the separation of nucleotides by pCEC have been investigated. In addition, the monolithic silica columns were also able to separate various polar compounds such as phenols, nucleic acid bases, and nucleosides in the hydrophilic interaction CEC mode.  相似文献   

10.
A pressurized CEC (pCEC) method was developed for the separation of phytohormones, in which UV absorbance was used as the detector and a monolithic silica-ODS column as the separation column. The parameters (including the concentration of organic solvent in the mobile phase, pH of the electrolyte buffer, applied voltage) affecting the separation resolution were evaluated. Two on-line concentration techniques, namely, solvent gradient zone sharpening effect and field-enhanced sample stacking, were utilized to improve detection sensitivity. The combination of the two techniques proved to be beneficial to enhance the detection sensitivity by enabling the injection of large volumes of samples. Compared to the conventional injection mode, the enhancement in the detection sensitivities of phytohormones using the on-line concentration technique is in the range from 9- to 23-fold. The developed pCEC method was applied to evaluate phytohormones in corns.  相似文献   

11.
Gao Y  Wang Y  Wang C  Gu X  Yan C 《色谱》2012,30(5):487-494
以N,N-二甲基-N-甲基丙烯酰胺基丙基-N,N-二甲基-N-丙烷磺酸内盐(SPP)为单体,季戊四醇三丙烯酸酯(PETA)为交联剂,偶氮二异丁腈(AIBN)为引发剂及两类不同的致孔剂(乙醇/乙二醇和甲醇/1,4-丁二醇)制备了两种新型亲水性整体柱。为了获得理想的柱效、电渗流速度和渗透性,对制备整体柱的各反应物配比进行了研究和优化。比较了两种整体柱在渗透性和分离样品方面的性能,结果表明,以乙醇/乙二醇为致孔剂制备的整体柱在柱效、分离度方面优于以甲醇/1,4-丁二醇为致孔剂制备的整体柱,但在渗透性方面不及后者。探讨了流动相中盐浓度对核苷类样品保留的影响,发现当甲酸铵浓度从10 mmol/L增加到70 mmol/L时,核苷样品的保留因子呈现先增加后减小的状态。将制备的整体柱用于毛细管液相色谱和加压电色谱分别分离胺类、酚类和核苷类样品,获得了理想的分离效果。在分离酚类和核苷类混合样品时,发现加压毛细管电色谱在分离度和分离速度上均优于毛细管液相色谱。  相似文献   

12.
Reversed-phase liquid chromatography with UV detection is of limited applicability in the separation and identification of carboxylic acids because of the column's poor separation efficiency and the non-selective nature of the UV detector. To address this issue, RP-LC with electrospray ionization mass spectrometry has been explored for the confirmation and determination of carboxylic acids in plant root exudates, with ESI-MS providing structural information, high selectivity, and high sensitivity. The separation of 10 carboxylic acids (pyruvic, lactic, malonic, maleic, fumaric, succinic, malic, tartaric, trans-aconitic, and citric acid) was performed on a C(18) column using an eluent containing 0.1% (v/v) acetic acid within 10 min, where the acidic eluent not only suppressed the ionization of the carboxylic acids to be retained on the column, but was also compatible with ESI-MS detection. In addition, an additional standard was used to overcome the matrix effect. The results showed that peak areas correlated linearly with the concentration of carboxylic acids over the range 0.05-10 mg/L. The detection limits of target acids (signal-to-noise S/N ratio of 3) ranged from 20 to 30 microg/L. Finally, the proposed method was used for the confirmation and determination of low-molecular-weight carboxylic acids in plant root exudates, and provided a simple analytical procedure, including sample processing, fast separation, and high specificity and sensitivity.  相似文献   

13.
Jia L  Liu Y  Du Y  Xing D 《Journal of chromatography. A》2007,1154(1-2):416-422
A pressurized capillary electrochromatography (pCEC) system was developed for the separation of water-soluble vitamins, in which UV absorbance was used as the detection method and a monolithic silica-ODS column as the separation column. The parameters (type and content of organic solvent in the mobile phase, type and concentration of electrolyte, pH of the electrolyte buffer, applied voltage and flow rate) affecting the separation resolution were evaluated. The combination of two on-line concentration techniques, namely, solvent gradient zone sharpening effect and field-enhanced sample stacking, was utilized to improve detection sensitivity, which proved to be beneficial to enhance the detection sensitivity by enabling the injection of large volumes of samples. Coupling electrokinetic injection with the on-line concentration techniques was much more beneficial for the concentration of positively charged vitamins. Comparing with the conventional injection mode, the enhancement in the detection sensitivities of water-soluble vitamins using the on-line concentration technique is in the range of 3 to 35-fold. The developed pCEC method was applied to evaluate water-soluble vitamins in corns.  相似文献   

14.
A pressurized CEC (pCEC) coupled with on-column chemiluminescence (CL) detection was developed for direct determination of amino acids, which was based on the principle of an enhanced effect of Cu(II)-amino acid complexes on the CL reaction between luminol and hydrogen peroxide in alkaline solution. The effects of some important factors on pCEC separation and CL intensity were systemically investigated. Baseline separation of amino acids including L-histidine (L-His), L-threonine (L-Thr), and L-tyrosine (L-Tyr) was achieved by using a monolithic column with a mobile phase of 5.0x10(-3) mol/L phosphate buffer at pH 8.0 that contained 25% v/v methanol and 5.0x10(-4) mol/L luminol and 1.0x10(-5) mol/L Cu(II) at an applied voltage of -5 kV. The calibration curves of the analytes by plotting the peak height against corresponding concentration were linear over the range of 3.2x10(-6)-3.2x10(-4) mol/L for L-His, 4.1x10(-6)-4.1x10(-4) mol/L for L-Thr, and 6.0x10(-7)-3.0x10(-4) mol/L for L-Tyr. The LODs for L-His, L-Thr, and L-Tyr were 6.4x10(-7), 8.4x10(-7), and 3.0x10(-7) mol/L (S/N = 2), respectively. The proposed method was applied to the analysis of amino acid injection sample with satisfactory results. Mean recoveries for three amino acids were from 84.3 to 89.6%.  相似文献   

15.
建立了整体柱离子对色谱-紫外检测法梯度淋洗快速分离测定4种吡啶离子液体阳离子的方法。分离采用C18反相硅胶整体柱,以离子对试剂(用柠檬酸调节pH值)-乙腈为淋洗液,并采用多级梯度洗脱程序。实验考察了色谱柱、离子对试剂、乙腈浓度、色谱柱温度及流速对吡啶阳离子保留的影响,并讨论了其保留规律。咪唑阳离子的保留符合碳数规律。最佳色谱条件是:在流速3.0 mL/min,柱温30℃下,以1.0 mmol/L庚烷磺酸钠(pH 4.0)(A)+乙腈(B)为淋洗液进行梯度洗脱。淋洗梯度为0~2.0 min,10%B;2.0~2.5 min,10%~15%B;2.5~4.0 min,15%B;4.0~4.5 min,15%~20%B;4.5~10.0 min,20%B。在此条件下,4种吡啶阳离子可在7 min内基线分离。所测阳离子的检出限(S/N=3)为0.05~0.17 mg/L;峰面积的相对标准偏差(n=5)小于0.6%。将本方法用于实验室合成的离子液体样品和污水样品的分析,加标回收率在95.7%~99.0%之间。本方法准确、快速,具有较好的实用性。  相似文献   

16.
A polar and neutral polymethacrylate-based monolithic column was evaluated as a hydrophilic interaction capillary electrochromatography (HI-CEC) stationary phase with small polar–neutral or charged solutes. The polar sites on the surface of the monolithic solid phase responsible for hydrophilic interactions were provided from the hydroxy and ester groups on the surface of the monolithic stationary phase. These polar functionalities also attract ions from the mobile phase and impart the monolithic solid phase with a given zeta potential to generate electro-osmotic flow (EOF). The monolith was prepared by in situ copolymerization of a neutral monomer 2-hydroxyethyl methacrylate (HEMA) and a polar cross-linker with hydroxy group, pentaerythritol triacrylate (PETA), in the presence of a binary porogenic solvent consisting cyclohexanol and dodecanol. A typical HI-CEC mechanism was observed on the neutral polar stationary phase for both neutral and charged analytes. The composition of the polymerization mixture was systematically altered and optimized by altering the amount of HEMA in the polymerization solution as well as the composition of the porogenic solvent. The monoliths were tested in the pCEC mode. The resulting monoliths had different characteristics of hydrophilicity, column permeability, and efficiency. The effects of pH, salt concentration, and organic solvent content on the EOF velocity and the separation of nucleic acids and nucleosides on the optimized monolithic column were investigated. The optimized monolithic column resulted in good separation and with greater than 140,000 theoretical plates/m for pCEC.  相似文献   

17.
Gu C  Lin L  Chen X  Jia J  Wu D  Fang N 《Journal of separation science》2007,30(17):2866-2873
A polymethacrylate-based monolithic column was prepared and its application to the separation of three kinds of similar microcystins (MCs) in capillary high performance liquid chromatography (capillary-HPLC) with ultraviolet detection was studied. The monolithic matrix contains both hydrophobic and cation-exchange interaction sites. Factors influencing the separation performance have been investigated. A baseline separation could be achieved by means of Tris(hydroxymethyl)aminomethane buffer of mildly alkaline pH and acetonitrile as the mobile phases in less than 5 min. The calibration curves were linear with a correlation coefficient r>0.9990 over a range of 0.25-18.00 mg/L. This method was successfully applied to the separation of microcystins from other compounds in spiked uncontaminated lake water after performing solid-phase extraction. The whole procedure provided low LODs, e. g. the LODs for MC-LR, MC-YR, and MC-RR were found to be 0.49, 0.67, 0.30 microg/L, respectively. The LODs, precision, efficiency, and the results obtained for the real samples demonstrate the potential of polymethacrylate-based monolithic columns as fast separation tools for routine use in the monitoring of microcystins in real water samples.  相似文献   

18.
Microwave irradiation can provide a viable alternative to the traditional means such as ultraviolet light and thermal initiation for the preparation of monolithic capillary columns. Polystyrene-based monolithic stationary phases were prepared in situ in fused-silica capillaries and simultaneously in vials. The column permeability, electrophoretic and chromatographic behavior were evaluated using pressure-assisted capillary electrochromatography (pCEC), capillary electrochromatography (CEC) and low pressure liquid chromatography (LPLC). With an optimal monolithic material, the largest theoretical plates for preparing the column could be close to 18,000 plates/m for thiourea in the mode of pCEC. Furthermore, the influence of the composition of the porogenic solvents (toluene/isooctane) on the morphology of organic-based monoliths [poly(styrene-divinylbenzene-methacrylic acid)] was systematically studied with mercury intrusion porosimetry and scanning electron microscopy. The monoliths which were prepared with a high content of isooctane had a bigger pore size and better permeability, and hence resulted in a faster separation.  相似文献   

19.
马伟  徐环昕  刘坐镇  宁方红 《色谱》2010,28(2):175-179
以甲基丙烯酸缩水甘油酯(GMA)为单体,二乙烯基苯(DVB)为交联剂,以环己醇和正十二醇为致孔剂,过氧化苯甲酰(BPO)为引发剂,直接以50 mm×4.6 mm色谱柱为模具,通过原位聚合制备聚(GMA-DVB)型整体柱。以GMA和DVB的体积比、环己醇和十二醇的体积比以及BPO占聚合物的质量分数为三因素,以分离苯和乙苯等小分子物质时的半峰宽分离度(R1/2)为考察指标,进行三因素三水平的正交试验,通过测定整体柱的比表面积、孔径和孔容分布对其进行表征。结果表明,制备整体柱的最优配方为V(GMA): V(DVB): V(环己醇): V(正十二醇)=0.825:0.825:1.32:2.03, BPO的质量分数为0.7%。应用所制备的整体柱分离苯和乙苯等小分子物质,理论塔板数达到37000塔板/m, R1/2值达到7.14,完全达到基线分离,分离时间小于10 min。该方法制备整体柱的重复性好,柱效较高,基本满足商品化要求。  相似文献   

20.
Proteomic studies have stimulated the development of novel stationary phases in miniaturised chromatographic columns that permit high linear flow velocities and exhibit high resolving power. In this work, a 50-microm reversed-phase silica-based monolith was chromatographically characterised for its use in proteomics applications using a nanoLC-MS set-up. It showed high efficiency for the separation of tryptic peptides under isocratic elution conditions (HETP(min)=5-10 microm at 2.4 mm/s). Flow rates up to 1.95 microL/min (18.4 mm/s) and gradient slopes up to an unusually fast 9% could be used. This resulted in rapid separations of peptide mixtures, with peak widths at half height of between 5 and 10 s. The 50-microm monolithic column was used to analyse depleted serum from a cervical cancer patient at a throughput of one sample per 30 min.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号