首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
An extraction/clean-up procedure by SFE was developed for isolating PAHs from liver samples for subsequent HPLC-FL determination of ten PAHs in the enriched extract. Recoveries (90-115%) and RSD % (< or =7.7) were satisfactory. When applied to 11 samples of bird of prey (Tyto alba) protected species and classified of special interest, from the Galicia (Northwest to Spain), benzo[ghi]perylene and indeno[1,2,3-cd]pyrene were undetectable; chrysene and benzo[a]pyrene are only detected in one sample; benzo[a]anthracene and benzo[k]fluoranthene are only quantified in one sample and benzo[b]fluoranthene in two samples. The other PAHs, anthracene, fluoranthene and pyrene are present in almost all the samples.  相似文献   

2.
A method capable of determining 13 PAHs (acenaphthene, anthracene, benzo[a]anthracene, benzo[a]pyrene, benzo[b]fluoranthene, benzo[k]fluoranthene, chrysene, dibenzo[ah]anthracene, fluoranthene, fluorene, indene[1,2,3-cd]pyrene, phenanthrene and pyrene) in a mixture of 16 EPA PAHs by second derivative synchronous spectrofluorometry in the constant wavelength mode was developed. It has not been possible to determine the following PAHs in the mixture: acenaphthylene, benzo[ghi]perylene and naphthalene. The approach studied allows the sensitive, rapid and inexpensive identification and quantitation of 13 PAHs in a solution of hexane. The detection limits are <1 microg L(-1) (except for chrysene and phenanthrene).  相似文献   

3.
In the present study, the solid–liquid extraction with low temperature purification was validated for the determination of 16 polycyclic aromatic hydrocarbons from sewage sludge by gas chromatography-mass spectrometry. Recoveries ranged 70–114% for naphthalene, acenaphthylene, acenaphthene, fluorene, phenanthrene, anthracene, fluoranthene, pyrene, benzo[a]anthracene and chrysene, while the compounds benzo[b]fluoranthene, benzo[k]fluoranthene, benzo[a]pyrene, indeno[1,2,3-cd]pyrene, dibenzo[a,h]anthracene and benzo[g,h,i]perylene showed recoveries of between 40 and 70%. The relative standard deviation was less than 13% for all of the compounds. Negative matrix effect was observed on the 10 compounds with less retention time in the chromatographic analysis and positive matrix effect noticed on the others. The limits of quantification were from 2 to 20 μg kg?1, about 30 times less than the maximum residue limit allowed in sludge by the European Union. The validated method produced quantification of 11 PAHs in one sludge sample at concentrations ranging 20–2000 μg kg?1.  相似文献   

4.
This paper presents the characterization of polycyclic aromatic hydrocarbons (PAHs) in solid-surface fluorescence as the first step for obtaining new optical sensors for PAHs screening. The fluorescence properties of the EPA-PAHs (naphthalene, acenaphthene, acenaphthylene, fluorene, phenanthrene, anthracene, fluoranthene, pyrene, chrysene, benzo[a]anthracene, benzo[k]fluoranthene, benzo[b]fluoranthene, benzo[a]pyrene, indeno [1,2,3-cd]pyrene, benzo[g,h,i]perylene and dibenzo[a,h]anthracene) on five types of solid-surfaces were evaluated. The experimental variables (pH and percentage of organic solvent in samples) were studied, obtaining different possibilities for making individual sensors for some of these PAHs and the best conditions for developing sensors for PAH screening were also studied.  相似文献   

5.
Supercritical fluid extraction was applied to the determination of naturally contaminated polycyclic aromatic hydrocarbons (PAHs) in bird tissue by liquid chromatography with fluorescence detection (LC-FL). Recoveries (> 90%) and relative standard deviations (< or = 7.7%) were satisfactory. The levels of 10 PAHs were analyzed in 6 classes of tissues (heart, liver, intestine, muscle, lung, and kidney) of 10 buzzards and 2 tawny owls, predatory birds from the Galicia (northwest Spain). The PAHs found most abundantly were pyrene, fluoranthene, benzo[a]anthracene, and anthracene. Chrysene, benzo[b]fluoranthene, benzo[k]fluoranthene, benzo[ghi]perylene, and indeno[1,2,3-cd]pyrene were not detected. Intestine, kidney, and lung were more polluted than other tissues.  相似文献   

6.
A microwave-assisted sample preparation (MASP) procedure was developed for the analysis of polycyclic aromatic hydrocarbons (PAHs) in sewage sludge and soil samples. The procedure involved the simultaneous microwave-assisted extraction of PAHs with n-hexane and the hydrolysis of samples with methanolic potassium hydroxide. Because of the complex nature of the samples, the extracts were submitted to further cleaning with silica and Florisil solid-phase extraction cartridges connected in series. Naphthalene, acenaphthene, fluorene, phenanthrene, anthracene, fluoranthene, pyrene, benz[a]anthracene, chrysene, benzo[e]pyrene, benzo[b]fluoranthene, benzo[k]fluoranthene, benzo[a]pyrene, dibenz[a,h]anthracene, benzo[g,h,i]perylene, and indeno[1,2,3-cd]pyrene, were considered in the study. Quantification limits obtained for all of these compounds (between 0.4 and 14.8 μg kg−1 dry mass) were well below of the limits recommended in the USA and EU. Overall recovery values ranged from 60 to 100%, with most losses being due to evaporation in the solvent exchange stages of the procedure, although excellent extraction recoveries were obtained. Validation of the accuracy was carried out with BCR-088 (sewage sludge) and BCR-524 (contaminated industrial soil) reference materials.  相似文献   

7.
This paper presents a trisolvent ultrasonic extraction and HPLC analysis method for the determination of 11 polycyclic aromatic hydrocarbons in air particulate collected on an air filter by a commercial high volume air sampler. A reverse phase column, Vydac 201 TP, and a gradient mobile phase, acetonitrile/water, were used. The 11 PAHs, fluoranthene, pyrene, benz[a]anthracene, chrysene, benzo[b]fluoranthene, benzo[k]fluoranthene, benzo[a]pyrene, dibenz[a, h]anthracene, benzo[ghi]perylene, indeno[1,2,3-cd]pyrene, and coronene were completely resolved under experimental conditions. All the PAHs except coronene were monitored by fluorescence with λex=270 nm, λem>389 nm. Coronene was monitored by UV with λ=300 nm. The methodology was evaluated by spiking SRM 1649 with a PAH standard and then going through different extraction procedures and analyzing the PAH concentrations without clean-up. An external standard method was used for quantitation. The recovery yields for fluoranthene, benz[a]anthracene, benzo[a]pyrene, benzo[ghi]perylene and indeno[l,2,3-cd]pyrene were above 90%. The detection limits of PAH with fluorescence at λex=270 nm, λem>389 nm ranged from 5.7 pg to 69.5 pg.  相似文献   

8.
With the emergence of highly sensitive analytical techniques, the microanalysis of natural-matrix materials employing smaller sample sizes is increasingly more common, which subsequently warrants a homogeneity assessment for the individual components at the appropriate sampling level. Pressurized liquid extraction (PLE) in combination with gas chromatography/mass spectrometry (GC/MS) has been used to determine the sampling constants and evaluate the relative homogeneity of trace levels of polycyclic aromatic hydrocarbons (PAHs) for two previously certified particulate standard reference materials, SRM 1649a Urban Dust and SRM 1650b Diesel Particulate Matter, in the milligram sampling range. Fluoranthene, pyrene, benz[a]anthracene and benzo[e]pyrene within SRM 1650b Diesel Particulate Matter were deemed to be homogeneous, based on relatively small sampling constants (K S<100 mg), whereas the larger sampling constants (K S>100 mg) obtained for all PAHs in SRM 1649a Urban Dust suggest more material heterogeneity. The material heterogeneity of ten individual PAHs (phenanthrene, anthracene, fluoranthene, pyrene, benz[a]anthracene, benzo[k]fluoranthene, benzo[e]pyrene, benzo[a]pyrene, indeno[1,2,3-cd]pyrene and benzo[ghi]perylene) was also described via nonlinear relationships (i.e., power law) between subsampling error S s (%) and sample mass, which are used to predict analyte-specific minimum sample masses that result in a specific level of analytical uncertainty. Electronic supplementary material Supplementary material is available for this article at and is accessible for authorized users.  相似文献   

9.
The formation of polycyclic aromatic hydrocarbons (PAHs) during pyrolysis process of phenylalanine had been studied. Ten PAHs, including fluorene, phenanthrene, anthracene, fluoranthene, pyrene, benzo[a]anthracene, chrysene, benzo[k]fluoranthene, benzo[e]pyrene, and benzo[a]pyrene were analyzed by gas chromatography-mass spectrometry using selective ion monitoring mode. This technique offers the capability to analyze trace amounts of PAHs in phenylalanine pyrolyzates. The pyrolysis was carried out in a micro-furnace with quartz furnace liner. The injection was conducted with glass pelletizer syringe to avoid metal contamination. Qualitative results were obtained at 900 degrees C and quantitative analysis of 10 PAHs was done for 700 and 900 degrees C.  相似文献   

10.
The most suitable wavelength intervals were selected for the determination of 4 polycyclic aromatic hydrocarbons (PAHs; benzo[g,h,i]perylene, dibenzo[a,h]anthracene, pyrene, and triphenylene) in very complex mixtures of 11 PAHs: anthracene, benz[a]anthracene, benzo[a]pyrene, benzo[b]fluoranthene, benzo[g,h,i]perylene, benzo[k]fluoranthene, chrysene, dibenz[a,h]anthracene, phenanthrene, pyrene, and triphenylene. The multiple linear regression algorithm was applied to measurements made in several wavelength intervals previously selected on the basis of sensitivity and minimum number of interfering compounds. Of the different models obtained, those displaying minimum error propagation in the analytical result were selected. By applying the models proposed in this study, we precisely and accurately determined benzo[g,h,i]perylene, dibenz[a,h]anthracene, pyrene, and triphenylene in complex mixtures--a feat that could not be achieved by the use of constant-wavelength spectrofluorimetry in combination with second-derivative techniques.  相似文献   

11.
In this paper an application of new procedures for atmospheric particulate analysis is illustrated. PM10, PAHs (benzo[a]anthracene (BaA), benzo[b]fluoranthene (BbF), benzo[j]fluoranthene (BjF), benzo[k]fluoranthene (BkF), benzo[a]pyrene (BaP), indeno[1, 2, 3-cd]pyrene (Ip), dibenzo[a, h]anthracene (DbA)) and heavy metals (Cu, Ni, Zn, Co, Mn, Cd, Fe and Pb) were investigated. PM10 determination was performed by gravimetric method, PAHs were measured by GC-MS, and heavy metals by HPIC. An air quality monitoring campaign on the territory of Bari municipality has been organised, and its results are shown.  相似文献   

12.
This study reported for the first time the use of cholesterol-functionalized magnetic nanoparticles (Fe3O4@SiO2@Chol) for the determination of polycyclic aromatic hydrocarbons (PAHs) in traditional Chinese medicine samples (TCMs) by high performance liquid chromatography (HPLC) coupled with fluorescence detection. The method was efficient, environmentally friendly, and fast. The solvent consumption of the proposed column is only half of the conventional column but with higher efficiency. Influencing factors, including sorbent amount, desorption solvent, sample volume and extraction time, were investigated in detail. Under the optimum conditions, good linearity (R2 > 0.991) was obtained over the range of 5–400 ng g−1, with limits of detection (LOD) 0.75, 0.50, 1.0, 0.56, 0.60, 0.84 and 0.80 ng g−1 for anthracene, fluoranthene, pyrene, chrysene, benzo[a]anthracene, benzo(b)fluoranthene and benzo(k)fluoranthene, respectively.  相似文献   

13.
A high-performance liquid chromatographic (HPLC) method with fluorescence detection was developed for the quantification of polycyclic aromatic hydrocarbons (PAHs) in human hair. Fifteen kinds of PAHs classified as priority pollutants by the US EPA were quantified with four perdeuterated PAHs as internal standards. After 50 mg hair samples were washed with n-hexane to remove external contamination of PAHs, the samples were digested in 2.5 M sodium hydroxide. The digests were extracted with n-hexane and then analyzed by HPLC. Eleven kinds of PAHs were identified in hair samples of 20 subjects, and 10 kinds of PAHs were eventually quantified using the internal standards. For anthracene, chrysene and benzo[k]fluoranthene, significant differences were observed between smokers and non-smokers. Although benzo[b]fluoranthene, dibenz[a,h]anthracene, benzo[ghi]perylene and indeno[1,2,3-cd]pyrene were observed in the particulates of indoor and outdoor air, they were not detected in all hair samples. The analysis of PAHs in human hair should be useful as a new biomarker to evaluate the exposure to PAHs.  相似文献   

14.
The efficiency of extraction of polycyclic aromatic hydrocarbons (PAHs) with molecular masses of 252, 276, 278, 300, and 302 Da from standard reference material diesel particulate matter (SRM 2975) has been investigated using accelerated solvent extraction (ASE) with dichloromethane, toluene, methanol, and mixtures of toluene and methanol. Extraction of SRM 2975 using toluene/methanol (9:1, v/v) at maximum instrumental settings (200 °C, 20.7 MPa, and five extraction cycles) with 30-min extraction times resulted in the following elevations of the measured concentration when compared with the certified and reference concentrations reported by the National Institute of Standards and Technology (NIST): benzo[b]fluoranthene, 46%; benzo[k]fluoranthene, 137%; benzo[e]pyrene, 103%; benzo[a]pyrene, 1,570%; perylene, 37%; indeno[1,2,3-cd]pyrene, 41%; benzo[ghi]perylene, 163%; and coronene, 361%. The concentrations of the following PAHs were comparable to the reference values assigned by NIST: indeno[1,2,3-cd]fluoranthene, dibenz[a,h]anthracene, and picene. The measured concentration of dibenzo[a,e]-pyrene was lower than the information value reported by the NIST. The measured concentrations of other highly carcinogenic PAHs (dibenzo[a,l]pyrene, dibenzo[a,i]pyrene, and dibenzo[a,h]pyrene) in SRM 2975 are also reported. Comparison of measurements using the optimized ASE method and using similar conditions to those applied by the NIST for the assignment of PAH concentrations in SRM 2975 indicated that the higher values obtained in the present study were associated with more complete extraction of PAHs from the diesel particulate material. Re-extraction of the particulate samples demonstrated that the deuterated internal standards were more readily recovered than the native PAHs, which may explain the lower values reported by the NIST. The analytical results obtained in the study demonstrated that the efficient extraction of PAHs from SRM 2975 is a critical requirement for the accurate determination of PAHs with high molecular masses in this standard reference material and that the optimization of extraction conditions is essential to avoid underestimation of the PAH concentrations. The requirement is especially relevant to the human carcinogen benzo[a]pyrene, which is commonly used as an indicator of the carcinogenic risk presented by PAH mixtures.  相似文献   

15.
Paolo Bruno  Maria Tutino 《Talanta》2007,72(4):1357-1361
The determination of polycyclic aromatic hydrocarbons (PAHs) contained in samples of particulate matter (PM), collected with low volume pumps, were carried out with an high sensitivity method that comes from several revisions of a previous method. The present work describes how, by using programmable temperature vaporization (PTV) and a mass selective detector with inert ionic source for the GC-MS analysis and the modifications of microwave-assisted extraction (MAE), the sensitivity of the method can be increased.The PAHs chosen for testing the method are: benzo[a]anthracene (BaA), benzo[b]fluoranthene (BbF), benzo[k]fluoranthene (BkF), benzo[a]pyrene (BaP), indeno[1,2,3-cd]pyrene (Ip) and dibenzo[a,h]anthracene (DbA). They, in fact, belong to that group of substances that are the most harmful for human health for their carcinogenicity.PAHs recoveries for spiked standard solutions at different concentrations were between 95 and 100% with relative standard deviation ranging from 1 to 3%. The revised method was validated using a 1649a urban dust standard reference material (SRM). The results obtained were in good agreement with certified values. The high sensitivity of the method allows to carry out analyses using only a half of the sampled filter (usually 47 mm diameter membranes). In this way, the other half can be used for the characterization of the other components of PM (heavy metals, organic carbon, ions, etc). The last step has been constituted by application of the optimized method on real samples collected in two cities located in Southern Italy (Bari and Taranto).  相似文献   

16.
In the presented study, comprehensive two-dimensional gas chromatography coupled to time-of-flight mass spectrometry (GC?×?GC-TOFMS) was shown to be a powerful tool for the simultaneous determination of various groups of contaminants including 18 polychlorinated biphenyls (PCBs), seven polybrominated diphenyl ethers (PBDEs), and 16 polycyclic aromatic hydrocarbons (PAHs). Since different groups of analytes (traditionally analyzed separately) were included into one instrumental method, significant time savings were achieved. Following the development of an integrated sample preparation procedure for an effective and rapid isolation of several groups of contaminants from fish tissue, the GC?×?GC-TOFMS instrumental method was optimized to obtain the best chromatographic resolution and low quantification limits (LOQs) of all target analytes in a complex mixture. Using large-volume programmable temperature vaporization, the following LOQs were achieved-PCBs, 0.01-0.25 μg/kg; PBDEs, 0.025-5 μg/kg; PAHs 0.025-0.5 μg/kg. Furthermore, several capillary column combinations (BPX5, BPX50, and Rxi-17Sil-ms in the first dimension and BPX5, BPX50, Rt-LC35, and HT8 in the second dimension) were tested during the experiments, and the optimal separation of all target analytes even of critical groups of PAHs (group (a): benz[a]anthracene, cyclopenta[cd]pyrene and chrysene; group (b): benzo[b]fluoranthene, benzo[j]fluoranthene and benzo[k]fluoranthene; group (c): dibenz[ah]anthracene, indeno[1,2,3-cd]pyrene and benzo[ghi]perylene) was observed on BPX5?×?BPX50 column setup. Moreover, since the determination of target analytes was performed using TOFMS detector, further identification of other non-target compounds in real life samples was also feasible.  相似文献   

17.
The total and bioaccessible concentration of 16 polycyclic aromatic hydrocarbons (PAHs) in soil from a former industrial site was investigated. Typical total concentrations across the sampling sites ranged from 1.5 mg kg−1 for acenaphthylene up to 243 mg kg−1 for fluoranthene. The oral bioaccessibility of PAHs in soil was assessed using an in vitro gastrointestinal extraction (Fed Organic Estimation human Simulation Test, FOREhST method). The oral bioaccessibility data indicated that fluorene, phenanthrene, chrysene, indeno(1,2,3-cd)pyrene and dibenzo(a,h)anthracene had the highest % bioaccessible fraction (based on their upper 75th percentile values being >60%) while the other PAHs had lower % bioaccessible fractions (means ranging between 35 and 59%). Significantly lower bioaccessibilities were determined for naphthalene. With respect to method validation and inter-laboratory comparison, the total and bioaccessible concentrations of benzo(a)anthracene, benzo(b)anthracene, benzo(k)fluoranthene, benzo(a)pyrene, indeno(1,2,3-cd)pyrene and dibenzo(a,h)anthracene was compared to published data derived using the same samples. The total PAH concentrations at the site were compared with generic assessment criteria (GAC) using the residential land use scenario (with plant uptake at 6% soil organic matter). Concentrations of 7 of the PAHs investigated within the soils could lead to an unacceptable risk to human health at this site.  相似文献   

18.
A fast and simple preparation procedure based on the matrix solid-phase dispersion (MSPD) technique is proposed for the first time for the isolation of 16 polycyclic aromatic hydrocarbons (PAHs) from soil samples. Naphthalene, acenaphthene, fluorene, phenanthrene, anthracene, fluoranthene, pyrene, benz[a]anthracene, chrysene, benzo[e]pyrene, benzo[b]fluoranthene, benzo[k]fluoranthene, benzo[a]pyrene, dibenzo[a,h]anthracene, benzo[g,h,i]perylene, and indeno[1,2,3-c,d]pyrene were considered in the study. Extraction and clean-up of samples were carried out in a single step. The main parameters that affect extraction yield, such as dispersant, type and amount of additives, clean-up co-sorbent and extractive solvent were evaluated and optimized. The addition of an alkali solution in MSPD was required to provide quantitative recoveries. Analytical determinations were carried out by high performance liquid chromatography (HPLC) with fluorescence detection. Quantification limits (between 0.01 and 0.6 ng g(-1) dry mass) were well below the regulatory limits for all the compounds considered. The extraction yields for the different compounds obtained by MSPD were compared with the yields obtained by microwave-assisted extraction (MAE). To test the accuracy of the MSPD technique, the optimized methodology was applied to the analysis of standard reference material BCR-524 (contaminated industrial soil), with excellent results.  相似文献   

19.
Nuno Ratola  Damià Barceló 《Talanta》2009,77(3):1120-1128
Two different extraction strategies (microwave-assisted extraction (MAE) and ultrasonic extraction (USE)) were tested in the extraction of the 16 US Environmental Protection Agency (EPA) polycyclic aromatic hydrocarbons (PAHs) from pine trees. Extraction of needles and bark from two pine species common in the Iberian Peninsula (Pinus pinaster Ait. and Pinus pinea L.) was optimized using two amounts of sample (1 g and 5 g) and two PAHs spiking levels (20 ng/g and 100 ng/g). In all cases, the clean-up procedure following extraction consisted in solid-phase extraction (SPE) with alumina cartridges. Quantification was done by gas chromatography (GC) with mass spectrometry (MS), using five deuterated PAH surrogate standards as internal standards. Limits of detection were globally below 0.2 ng/g. The method was robust for the matrices studied regardless of the extraction procedures. Recovery values between 70 and 130% were reached in most cases, except for high molecular weight PAHs (indeno[1,2,3-cd]pyrene, dibenzo[a,h]anthracene and benzo[ghi]perylene). A field study with naturally contaminated samples from eight sites (four in Portugal and four in Catalonia, Spain) showed that needles are more suitable biomonitors for PAHs, yielding concentrations from 2 to 17 times higher than those found in bark. The levels varied according to the sampling site, with the sum of the individual PAH concentrations between 213 and 1773 ng/g (dry weight). Phenanthrene was the most abundant PAH, followed by fluoranthene, naphthalene and pyrene.  相似文献   

20.
Olivella MA 《Talanta》2006,69(1):267-275
An innovative analytical procedure for the analysis of polycyclic aromatic hydrocarbons (PAHs) from large-volume water samples is presented. It involves sample preparation, sampling and the elution process in an automated continuous procedure involving the ASE technique. Prior to sampling, a XAD-2 resin column is prepared on the basis of a commercial accelerated solvent extraction (ASE) cartridge so that the resin bed is permanently fixed. Then, the XAD column inside the ASE cartridge is cleaned and conditioned. The sampling procedure involves conventional filtration with subsequent isolation of dissolved PAHs on an XAD-2 resin contained in the ASE cartridge. After sampling, the XAD-2 resin content inside the cartridge is eluted by ASE without any further sample preparation and subsequently reused. In order to validate the procedure, the PAHs were isolated from water samples from the Lake Maggiore (North of Italy) using both XAD-2 resin adsorption and hexane liquid-liquid extraction according to the International Standard Methodology ISO 17993. The mean percentages of deviation between concentrations obtained by both methodologies range from 6% for benzo(a)pyrene to 15% for fluoranthene and benzo(b,k)fluoranthene. Compared to the traditional techniques, this procedure offers numerous practical advantages: easy to perform, fast, savings in solvent volume and in time, all steps are fully automated thus avoiding any XAD-2 resin manipulation during and between steps and moreover, low detection limits were provided (0.001 ng l−1 for chrysene, benzo(b,k)fluoranthene, benzo(a)pyrene, dibenz(a,h)anthracene, benzo(g,h,i)perylene and indeno(1,2,3-cd)pyrene, and 0.01 ng l−1 for acenaphthylene and fluoranthene).This procedure was developed in the frame of a project aimed at evaluating the diffuse input of organic contaminants in the Lake Maggiore.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号