首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 125 毫秒
1.
The application of peptides in chiral separations using techniques such as capillary electrophoresis (CE), electrokinetic capillary chromatography (EKC) and liquid chromatography is the focus of this review. Methods for finding peptide selectors using combinatorial library approaches are discussed, as well as recent advances in the use of peptides as general chiral selectors for electrophoresis and liquid chromatography. One example shows the effectiveness of polymeric dipeptide surfactants as general chiral selectors for electrophoresis. Another example shows the versatility of oligoproline chiral stationary phases, exhibiting resolution for a number of racemic analytes comparable to other well-established chiral stationary phases.  相似文献   

2.
非水溶液毛细管电泳手性分离   总被引:3,自引:0,他引:3  
对非水溶液毛细管电泳中手性分离的研究现状和发展趋势进行了简要的评述。主要是以手性分离中所用的手性试剂为线索,对它们在非水溶液中的应用情况及其对分离度、柱效和分离选择性的影响进行综述并与水溶液中的情况作了比较。对于在水溶液中已经得到应用而在非水溶液中未被使用的部分试剂也进行了简要地解释。  相似文献   

3.
《Analytical letters》2012,45(15):2356-2371
Today, capillary zone electrophoresis (CZE) is became an established method for the determination of chiral impurities. A method for the enantioresolution of these benzoxazolinone aminoalcohols and their aminoketon precursors, potential adrenergic ligands, was developed using neutral and anionic cyclodextrins as chiral selectors. Operational parameters, such as the nature and concentration of the chiral selectors, temperature, and applied voltage, were investigated. The influence of the structural features of the solutes on migration time and resolution was studied. The apparent and averaged binding constants of complexes were calculated.  相似文献   

4.
A theoretical investigation was carried out on the retention and separation of enantiomeric molecules including nonsteroidal anti-inflammatory drugs, anti-neoplastic compounds and N-derivatized amino acids by capillary electrophoresis using macrocyclic antibiotics, a new class of chiral selectors, as stationary phase. Firstly docking methods were used to study the enantiorecognition in chiral electrophoresis. The molecular dynamics simulations of the two diastereoisomer complexes were then performed in order to understand how these antibiotics recognize the enantiomers. Another approach was applied in this study to establish a quantitative structure-enantioselectivity relationship (QSER) model, able to describe the resolution of a series of chiral compounds in capillary electrophoresis using vancomycin as the resolving agent.  相似文献   

5.
毛细管区带电泳法研究肾上腺素类药物的手性分离   总被引:9,自引:1,他引:8  
使用β-环糊精(β-CD)及β-CD-羧甲基(CM-β-CD)作为手性选择剂,采用毛细管区带电泳法(CZE)对去甲肾上腺素、肾上腺素和异丙肾上腺素的手性分离进行了研究。对影响这类药物手性分离的主要因素〔手性选择剂、背景电解质(BGE)、分离体系的酸度和温度〕进行了讨论,并对手性识别机理进行了探讨。  相似文献   

6.
Capillary zone electrophoresis was used for the enantiomeric separation of six β-blocking drug substances with β-cyclodextrin (β-CD) and its derivatives as chiral selectors employing an uncoated capillary. The effects of pH value and composition of the background electrolyte (BGE), the capillary temperature and running voltage have been investigated. The results showed that β-CD type, concentration and pH value have a strong influence on the efficiency of the chiral separation. Carboxymethyl-β-cyclodextrin (CM-β-CD) gave a baseline enantiomeric separation for six β-blocking drug substances under optimal conditions, whereas the β-CD, hydroxypropyl-β-cyclodextrin (HP-β-CD) showed no chiral recognition. The potential and capillary temperature did not have a great effect on enantiomer resolution.  相似文献   

7.
Due to the importance of chiral separations of drugs, pharmaceuticals, agrochemicals and xenobiotics by high performance liquid chromatography (HPLC) and capillary electrophoresis (CE), it is important to have the knowledge of the enantiomeric recognition mechanisms so that scientists may design and module the new chiral selectors for rapid, inexpensive and reproducible chiral separations; specially at preparative scale. The mechanisms of the chiral separation by HPLC and CE using polysaccharides, cyclodextrins, macrocyclic glycopeptide antibiotics, Pirkle type, ligand exchangers, crown ethers and other several types of chiral selectors have been discussed. Various complex formation and different types of interactions responsible for chiral resolution have been presented in detail.  相似文献   

8.
毛细管电泳在手性化合物分离中的应用   总被引:4,自引:0,他引:4  
本文综述了近年来毛细管电泳在手性化合物分离中的应用情况。简要地总结和比较了手性配位体金属络合物、环糊精及其衍生物、开环多糖化合物、冠醚、大环化合物等5种典型的手性分子识别剂在毛细管电泳手性分离中的使用现状。  相似文献   

9.
A novel chiral selector, clindamycin succinate, was synthesized and first used as a chiral selector in capillary electrophoresis (CE). The chiral resolution ability of this kind of clindamycin derivation was studied by CE using some racemic drugs as model analytes. From the experimental results, it was found that both resolution and selectivity of the selector were dependent on the following parameters: concentration of chiral selectors, pH of the running buffer, temperature of the capillary column, applied voltage and organic modifier used. The results show that the chiral selector possesses high resolution toward some racemic drugs, including ofloxacin, chlorphenamine, tryptophan, propranolol, sotalol and metoprolol. Excellent chiral resolution of these tested drugs was achieved under the optimal conditions of 50 mM clindamycin succinate, 10% MeOH v/v, 50 mM Tris buffer, pH 4.0, at 22 kV and 20 °C within 25 min.  相似文献   

10.
Many chemical and biological processes are controlled by the stereochemistry of small polypeptides (di‐, tri‐, tetra‐, penta‐, hexapeptides, etc). The biological importance of peptide stereoisomers is of great value. Therefore, the chiral resolution of peptides is an important issue in biological and medicinal sciences and drug industries. The chiral resolutions of peptide racemates have been discussed with the use of capillary electrophoresis and chromatographic techniques. The various chiral selectors used were polysaccharides, cyclodextrins, Pirkle types, macrocyclic antibiotics, crown ethers, imprinted polymers, etc. The stereochemistry of dipeptides is also discussed. Besides, efforts are made to explain the chiral recognition mechanisms, which will be helpful in understanding existing and developing new stereoselective analyses. Future perspectives of enantiomeric resolution are also predicted. Finally, the review concludes with the demand of enantiomeric resolution of all naturally occurring and synthetic peptides.  相似文献   

11.
毛细管电泳的手性拆分(文献综述)   总被引:2,自引:0,他引:2  
根据最近文献,对毛细管电泳在手性拆分领域中的应用和发展进行了评述,包括各种操作模式和各类手性选择剂,进一步评述了手性拆分机理的研究,显示出毛细管电泳是手性拆分的一种高效、快速、简便的分离手段。  相似文献   

12.
毛细管电泳的手性拆分(文献综述)   总被引:14,自引:1,他引:13  
朱晓峰  林炳承 《色谱》1999,17(2):153-157
 根据最近文献,对毛细管电泳在手性拆分领域中的应用和发展进行了评述,包括各种操作模式和各类手性选择剂,进一步评述了手性拆分机理的研究,显示出毛细管电泳是手性拆分的一种高效、快速、简便的分离手段。  相似文献   

13.
《Electrophoresis》2017,38(9-10):1383-1390
We recently reported that a great variety of DNA oligonucleotides (ONs) used as chiral selectors in partial‐filling capillary electrophoresis (CE) exhibited interesting enantioresolution properties toward low‐affinity DNA binders. Herein, the sequence prerequisites of ONs for the CE enantioseparation process were studied. First, the chiral resolution properties of a series of homopolymeric sequences (Poly‐dT) of different lengths (from 5 to 60‐mer) were investigated. It was shown that the size increase‐dependent random coil‐like conformation of Poly‐dT favorably acted on the apparent selectivity and resolution. The base‐unpairing state constituted also an important factor in the chiral resolution ability of ONs as the switch from the single‐stranded to double‐stranded structure was responsible for a significant decrease in the analyte selectivity range. Finally, the chemical diversity enhanced the enantioresolution ability of single‐stranded ONs. The present work could lay the foundation for the design of performant ON chiral selectors for the CE separation of weak DNA binder enantiomers.  相似文献   

14.
Summary The chiral separation of two newly synthesized arylpropionic acids of pharmaceutical interest, namely 2-[(5′-benzoil-2′-hydroxy)phenyl]-propionic acid (DF-1738y) and 2-[(4′-benzoiloxy-2′-hydroxy)phenyl]-propionic acid (DF-1770y), was performed by Capillary Zone Electrophoresis (CZE) using either cyclodextrins or antibiotics as chiral selectors in coated capillary. In order to optimize the separation, the effect on the migration time and resolution of type and concentration of the chiral selector, the buffer pH and the capillary temperature were studied. Several cyclodextrins, namely the charged 6A-monomethylamino-β-cyclodextrin (MeNH-β-CD) and the neutral methyl-β-cyclodextrins (M-β-CD) and heptakis-2,3,6-tri-O-methyl-β-cyclodextrin (TM-β-CD), were tested for the enantiomeric separation of aryl propionic acids (APAs) compounds. Of these TM-β-CD provided the highest enantiomeric resolution at pH 5, however only DF-1738y optical isomers were baseline resolved. Using background electrolytes (BGEs) at higher pHs (pH=6–7) supported with the above listed CDs, an enantioresolution increase was recognized only for compound DF-1738y. In contrast DF-1770y exhibited the highest resolution at the lowest pH value studied (pH 4). The macrocyclic antibiotic vancomycin was therefore added to the BGE and tested as chiral selector using the partial filling counter current mode in order to obtain a sensitive analysis, high resolution and reduced antibiotic adsorption on the capillary wall. 5 mM vancomycin dissolved in the BGE at pH 5 and 25°C provided relatively high enantiomeric resolution (R DF-1738y=3.4,R DF-1770y=2.22) of both compounds.  相似文献   

15.
The sensitivity of coupled enantioselective capillary electrophoresis-mass spectrometry (CE-MS) of amino acids (AAs) is often hampered by the chiral selectors in the background electrolyte (BGE). A new method is presented in which the use of a chiral selector is circumvented by employing (+)-1-(9-fluorenyl)ethyl chloroformate (FLEC) as chiral AA derivatizing agent and ammonium perfluorooctanoate (APFO) as a volatile pseudostationary phase for separation of the formed diastereomers. Efficient AA derivatization with FLEC was completed within 10 min. Infusion experiments showed that the APFO concentration hardly affects the MS response of FLEC-AAs and presents significantly less ion suppression than equal concentrations of ammonium acetate. The effect of the pH and APFO concentration of the BGE and the capillary temperature were studied in order to achieve optimized enantioseparation. Optimization of CE-MS parameters, such as sheath-liquid composition and flow rate, ESI and MS settings was performed in order to prevent analyte fragmentation and achieve sensitive detection. Selective detection and quantification of 14 chiral proteinogenic AAs was achieved with chiral resolution between 1.2 and 8.6, and limits of detection ranging from 130 to 630 nM injected concentration. Aspartic acid and glutamic acid were detected, but not enantioseparated. The optimized method was applied to the analysis of chiral AAs in cerebrospinal fluid (CSF). Good linearity (R2 > 0.99) and acceptable peak area and electrophoretic mobility repeatability (RSDs below 21% and 2.4%, respectively) were achieved for the chiral proteinogenic AAs, with sensitivity and chiral resolution mostly similar to obtained for standard solutions. Next to l-AAs, endogenous levels of d-serine and d-glutamine could be measured in CSF revealing enantiomeric ratios of 4.8%–8.0% and 0.34%–0.74%, respectively, and indicating the method's potential for the analysis of low concentrations of d-AAs in presence of abundant l-AAs.  相似文献   

16.
In this study, the applicability of a chiral ionic liquid (CIL) as the sole chiral selector in CE was investigated for the first time. In particular, five amino acid ester‐based CILs were synthesized and used as additives in the BGE in order to evaluate their chiral recognition ability. The performance of these CILs as the sole chiral selectors was evaluated by using 1,1′‐binaphthyl‐2,2‐diylhydrogenphosphate (BNP) as the analyte and by comparing the resolution values. Different parameters were examined, such as the alkyl group bulkiness and the configuration of the cation, the anion type of the CIL and its concentration, and the pH of the BGE, in order to optimize the separation of the enantiomers and to demonstrate the effect that each parameter has on the chiral‐recognition ability of the CIL. Baseline separation of BNP within 13 min was achieved by using a BGE of 100 mM Tris/10 mM sodium tetraboratedecahydrate (pH 8) and a chiral selector of 60 mM l ‐alanine tert butyl ester lactate. The run‐to‐run and batch‐to‐batch reproducibilities were also evaluated by computing the %RSD values of the EOF and the two enantiomer peaks. In both cases, very good reproducibilities were observed, since all %RSD values were below 1%.  相似文献   

17.
Summary Different approaches how to handle the electromigration dispersion process that occurs in separation and determination of enantiomers are presented. The use of cyclodextrins as chiral selectors in resolution enantiomers involves the possibility to tune the conductivity of the sample band in order to obtain symmetrical and efficient peaks. Determination of impurities that migrate in the rear part of an overloaded main peak can be accomplished if the conductivity of the background electrolyte (BGE) is adapted to the conductivity of the sample band. This strategy was shown in determination of the content of D-sotalol in a mixture of L and D-sotalol. The efficiency and the symmetry of the overloaded L-sotalol peak was substantially improved by substitution of tetrabutylammonium ions for tetrapentylammonium ions as co-ions in the BGE. In this system it was possible to determine 0.2% w/w of the chiral impurity D-sotalol. A resolution model is presented and used qualitatively in the study where the complexation between the tetraalkyllammonium ions and the cyclodextrins is taken into account.  相似文献   

18.
Summary A wide series of L-phenylalanine tetraamide selectors (Phe-n-O-TA) have been synthesized and used as stationary phases for chiral resolution of D,L-amino acids by capillary gas chromatography. The influence of length and polarity of the oxaalkanoyl bridge spacing the diamide chains of the selectors and the effects of steric hindrance on separating power were investigated. The characteristics of the chiral columns and the separation factors of D,L-n-butyl-N-trifluoroacetyl amino esters are reported.  相似文献   

19.
程燕  白敏  王新梅  明永飞  尤进茂 《色谱》2006,24(2):188-191
以咔唑-9-乙基氯甲酸酯(CEOC)作为柱前衍生试剂,采用毛细管电泳对14种二肽进行了手性拆分。以5种二肽为代表,考察了缓冲液种类、浓度、pH值、二元手性选择剂的组合配比等因素对二肽的拆分效果,优化了实验条件。在各自的优化条件下,14种二肽手性拆分的分离度均在3.63以上,最高分离度可达43.14(Gly-Ala)。  相似文献   

20.
Uncharged cyclodextrins were tested as chiral selectors for the enantiomeric separation of 13 glycyl dipeptides with capillary electrophoresis. Initial experiments were performed on 10 mmol/L of a cyclodextrin in 0.1 mol/L phosphoric acid -0.088 mol/L triethanolamine. Some of the resolved dipeptides were nonaromatic, which is noteworthy since, to our knowledge, no examples of the separation of small, nonaromatic molecules have been published. Mobility difference plots for Gly-DL-Leu and Gly-DL-Phe with heptakis(2,6-di-O-methyl)-beta-cyclodextrin showed relatively flat profiles in a large concentration range, which is an advantage for the development of robust quantitative analytical methods. The use of a background electrolyte (BGE) solution with pH 3.0 gave irreproducible results for two of the dipeptides, the acidic Gly-DL-Asp and Gly-DL-Glu; this pH is not advisable for the development of robust methods for these two peptides. The need for purer chiral selectors was demonstrated by comparing different batches of heptakis(2,6-di-Omethyl)-beta-cyclodextrin from the same supplier. A BGE consisting of malonic acid and triethanolamine was introduced to give better buffer capacity than the original BGE at pH 3.0.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号