首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
Zhu L  Chen Y  Wu Y  Li X  Tang H 《Analytica chimica acta》2006,571(2):242-247
A new method for chemical oxygen demand (COD) determination has been developed, based on photocatalytic oxidative degradation by using a fluorinated-TiO2-KMnO4 system. In such a system, a linear correlation is observed between the amount of oxidizable dissolved organic matter and the amount of MnO4 consumed by the coupled reduction process. Thus, the COD determination is transformed to a simple and direct determination of the deletion of MnO4. The surface fluorination of TiO2 nanoparticles can enhance the rate of photocatalytic oxidation of organic matter and the rate of coupled photocatalytic reduction of MnO4. This makes the method be rapid, environment friendly and easy for operation. Under optimized conditions, this method can respond linearly to COD of potassium hydrogen phthalate (KHP) in the range of 0.1-280 mg L−1, with a detection limit of 0.02 mg L−1 COD. The COD in samples of tap water, lake water and paper industry sewage has been determined satisfactorily by using this method.  相似文献   

2.
A FIA-amperometric method for azithromycin determination was developed. A working glassy carbon electrode and a Ag/AgCl/NaCl (3 M) reference electrode were used. The determination is based on the electrochemical oxidation of the azithromycin at 0.9 V in Britton-Robinson buffer solution (pH 8.0). Due to the adsorption of the reaction products on the electrode surface, an effective cleaner cycle was implemented. By using the optimum chemical and FIA conditions, a concentration linear range of 1.0-10.0 mg L−1 and a detection limit (LOD) of 0.76 mg L−1 are obtained. The method was validated and satisfactorily applied to the determination of azithromycin in pharmaceutical formulations.  相似文献   

3.
Zhonghai Zhang 《Talanta》2007,73(3):523-528
A composite nano-ZnO/TiO2 film as photocatalyst was fabricated with vacuum vaporized and sol-gel methods. The nano-ZnO/TiO2 film improved the separate efficiency of the charge and extended the range of spectrum, which showed a higher efficiency of photocatalytic than the pure nano-TiO2 and nano-ZnO film. The photocatalytic mechanism of nano-ZnO/TiO2 film was discussed, too. A new method for determination of low chemical oxidation demand (COD) value in ground water based on nano-ZnO/TiO2 film using the photocatalytic oxidation technology was founded. This method was originated from the direct determination of the Mn(VII) concentration change resulting from photocatalytic oxidation of organic compounds on the nano-ZnO/TiO2 film, and the COD values were calculated from the absorbance of Mn(VII). Under the optimal operation conditions, the detection limit of 0.1 mg l−1, COD values with the linear range of 0.3-10.0 mg l−1 were achieved. The results were in good agreement with those from the conventional COD methods.  相似文献   

4.
Melchert WR  Rocha FR 《Talanta》2005,65(2):461-465
Nitrate determination in waters is generally carried out with cadmium filings and carcinogenic reagents or by reaction with phenolic compounds in highly concentrated sulfuric acid medium. In this work, it was developed a green analytical procedure for nitrate determination in natural waters based on direct spectrophotometric measurements in ultraviolet, using a flow-injection system with an anion-exchange column for separation of nitrate from interfering species. The proposed method employs only one reagent (HClO4) in a minimum amount (equivalent to 18 μL concentrated acid per determination), and allowed nitrate determination within 0.50-25.0 mg L−1, without interference of up to 200.0 mg L−1 humic acid; 1.0 mg L−1 NO2; 200.0 mg L−1 PO43−; 75.0 mg L−1 Cl; 50.0 mg L−1 SO42− and 15.0 mg L−1 Fe3+. The detection limit (99.7% confidence level) and the coefficient of variation (n = 20) were estimated as 0.1 mg L−1 and 0.7%, respectively. The results obtained for natural water samples were in agreement with those achieved by the reference method based on nitrate reduction with copperized cadmium at the 95% confidence level.  相似文献   

5.
A sequential injection method (SIA) for carbon speciation in inland bathing waters was developed comprising, in a single manifold, the determination of dissolved inorganic carbon (DIC), free dissolved carbon dioxide (CO2), total carbon (TC), dissolved organic carbon and alkalinity. The determination of DIC, CO2 and TC was based on colour change of bromothymol blue (660 nm) after CO2 diffusion through a hydrophobic membrane placed in a gas diffusion unit (GDU). For the DIC determination, an in-line acidification prior to the GDU was performed and, for the TC determination, an in-line UV photo-oxidation of the sample prior to GDU ensured the conversion of all carbon forms into CO2. Dissolved organic carbon (DOC) was determined by subtracting the obtained DIC value from the TC obtained value. The determination of alkalinity was based on the spectrophotometric measurement of bromocresol green colour change (611 nm) after reaction with acetic acid. The developed SIA method enabled the determination of DIC (0.24–3.5 mg C L−1), CO2 (1.0–10 mg C L−1), TC (0.50–4.0 mg C L−1) and alkalinity (1.2–4.7 mg C L−1 and 4.7–19 mg C L−1) with limits of detection of: 9.5 μg C L−1, 20 μg C L−1, 0.21 mg C L−1, 0.32 mg C L−1, respectively. The SIA system was effectively applied to inland bathing waters and the results showed good agreement with reference procedures.  相似文献   

6.
This paper proposes a method for determination of chemical oxygen demand (COD) in domestic wastewater. The proposed method is based on near-infrared reflectance (NIRR) measurements of seston collected from wastewater samples by filtration. The analysis does not require any special reagent, catalyst or solvent. Inherent baseline and noise features present in NIRR spectra are removed by a Savitzky-Golay derivative procedure followed by wavelet denoising. The resulting wavelet approximation coefficients are used for partial-least-squares modelling and subsequent prediction of COD values in new samples. The model is calibrated by using COD values obtained according to the American Public Health Association (APHA) reference method. The proposed method is applied to effluent samples from the anaerobic ponds of the Mangabeira municipal wastewater treatment plant in the city of João Pessoa (Paraíba, Brazil). By comparing the NIRR prediction results with the APHA reference values, a root-mean-square error of prediction (RMSEP) of 19 mg O2 L−1 and a correlation of 0.97 were obtained. Such results are deemed adequate in view of the joint estimate of the standard error of the reference method, which was calculated as 21 mg O2 L−1.  相似文献   

7.
A novel and high throughput chemiluminescence (CL) method for determination of chemical oxygen demand (COD) in water sample was originally developed based on potassium permanganate-glutaraldehyde CL system. With this method, dissolved organic matter in water samples was digested by excess acid potassium permanganate, the reacted mixture solutions containing surplus KMnO4 were added in wells of a 96-well plate, followed by injection of glutaraldehyde in the wells, and CL was then produced along with the reaction of the added glutaraldehyde with the surplus KMnO4 and detected by a photomultiplier tube (PMT). The difference (ΔI) between the CL intensity for distilled water and that for sample water was proportional to the COD value of water sample. The calibration graph was linear in the range of 0.16-19.24 mg L−1 with a detection limit of 0.1 mg L−1. A complete analysis could be performed in 40 min including digestion and detection, giving a very high throughput of 3 × 96 samples in about 60 min. Compared with the conventional methods, this method is simple and sensitive and consumes very limited and cheap reagents. Owing to its rapid, automatic, high throughput and low cost characteristics, the presented CL method has been applied successfully to the determination of COD in real water samples (n = 32) with satisfactory results.  相似文献   

8.
Li J  Li L  Zheng L  Xian Y  Jin L 《Talanta》2006,68(3):765-770
A COD measurement by a photocatalytic oxidation method using nano-TiO2 film was investigated. K2Cr2O7 was added into the solution to enhance the efficiency of photocatalytic degradation, and simultaneously K2Cr2O7 was reduced to Cr(III) by photogenerated electrons, which were adsorbed on the surface of TiO2. The measuring principle was based on direct determination of Cr(III) concentration which was proportional to the COD value. Under the optimized experiment condition, the application range was 20-500 mg l−1, and the detection limit was 20 mg l−1. The immobilization of photocatalyst on the supports could not only solve the problem of low recovery of the catalyst and hard separation from the solution, but also overcome its shortcoming of poor stability. Applied this method to the determination of real samples, it was found to be rapid and environmentally friendly. Additionally, the method proposed above for determination of COD was in excellent correspondence with values obtained by using the conventional method.  相似文献   

9.
A multi-pumping flow system (MPFS) for the spectrophotometric determination of dissolved orthophosphate and dissolved organic phosphorus in wastewater samples is proposed. The determination of orthophosphate is based on the vanadomolybdate method. In-line ultraviolet photo-oxidation is employed to mineralise organic phosphorus to orthophosphate prior to detection. A solenoid valve allows the deviation of the flow towards the UV-lamp to carry out the determination of organic phosphorus.Calibration was found to be linear up to 20 mg P L−1, with a detection limit (3sb/S) of 0.08 mg P L−1, an injection throughput of 75 injections h−1 and a repeatability (R.S.D.) of 0.6% for the direct determination of orthophosphate. On the other hand, calibration graphs were linear up to 40 mg P L−1, with a detection limit (3sb/S) of 0.5 mg P L−1, an injection throughput of 11 injections h−1 and a repeatability (R.S.D.) inferior to 2.3% for the procedures involving UV photo-oxidation.  相似文献   

10.
An on-line system with vapour generation (VG) and Fourier transform infrared (FTIR) spectrometric detection has been developed for the determination of free ammonium and organic nitrogen in agrochemical formulations containing hydrolyzed proteins. Commercial samples were digested, in batch mode, with sulphuric acid and the obtained solution was alkalinized on-line to transform the NH4+ to NH3 that was continuously monitored by FTIR. Free ammonium was determined in the same system after simple dilution of undigested samples with water. Different gas phase separators were assayed in order to introduce gaseous NH3 into a home made IR gas cell of 10 cm pathlength, where the corresponding FTIR spectra were acquired by accumulating 10 scans per spectrum. The 967.0 cm−1 band was used for the quantification of ammonia. The figures of merit of the proposed method involve a linear range up to 100 mg L−1, a limit of detection (3σ) of 1.4 mg L−1 of N, a limit of quantification (10σ) of 4.8 mg L−1 of N, a precision (R.S.D.) of 3.0% for 10 replicate determinations of a 10.0 mg L−1 of N and a sample measurement frequency of 60 h−1. The method was successfully applied to the determination of free ammonium and total N in commercial amino acid formulations and results compare well with those obtained by the Kjeldhal method.  相似文献   

11.
The design and construction of a highly selective voltammetric sensor for metronidazole by using a molecularly imprinted polymer (MIP) as recognition element were introduced. A metronidazole selective MIP and a nonimprinted polymer (NIP) were synthesized and then incorporated in the carbon paste electrodes (CPEs). The sensor was applied for metronidazole determination using cathodic stripping voltammetric method. The MIP-CP electrode showed very high recognition ability in comparison to NIP-CPE. Some parameters affecting the sensor response were optimized and then the calibration curve was plotted. Two dynamic linear ranges of 5.64 × 10−5 to 2.63 × 10−3 mg L−1 and 2.63 × 10−3 to 7.69 × 10−2 mg L−1 were obtained. The detection limit of the sensor was calculated as 3.59 × 10−5 mg L−1. This sensor was used successfully for metronidazole determination in biological fluids.  相似文献   

12.
Hydrogen peroxide and nicotinamide adenine dinucleotide (NADH) may be determined amperometrically using screen-printed electrodes chemically modified with iron(III) hexacyanoosmate(II) (Osmium purple) in flow injection analysis (FIA). The determination is based on the exploitation of catalytic currents resulting from the oxidation/reduction of the modifier. The performance of the sensor was characterized and optimized by controlling several operational parameters (applied potential, pH and flow rate of the phosphate buffer). Comparison has been made with analogous complexes of ruthenium (Ruthenium purple) and iron (Prussian blue). Taking into account the sensitivity and stability of corresponding sensors, the best results were obtained with the use of Osmium purple. The sensor exhibited a linear increase of the amperometric signal with the concentration of hydrogen peroxide in the range of 0.1-100 mg L−1 with a detection limit (evaluated as 3σ) of 0.024 mg L−1 with a R.S.D. 1.5% for 10 mg L−1 H2O2 under optimized flow rate of 0.4 mL min−1 in 0.1 M phosphate buffer carrier (pH 6) and a working potential of +0.15 V versus Ag/AgCl. Afterwards, a biological recognition element - either glucose oxidase or ethanol dehydrogenase - was incorporated to achieve a sensor facilitating the determination of glucose or ethanol, respectively. The glucose sensor gave linearity between current and concentration in the range from 1 to 250 mg L−1 with a R.S.D. 2.4% for 100 mg L−1 glucose, detection limit 0.02 mg L−1 (3σ) and retained its original activity after 3 weeks when stored at 6 °C. Optimal parameters in the determination of ethanol were selected as: applied potential +0.45 V versus Ag/AgCl, flow rate 0.2 mL min−1 in 0.1 M phosphate buffer carrier (pH 7). Different structural designs of the ethanol sensor were tested and linearity obtained was up to 1000 mg L−1 with a maximum R.S.D. of 5.1%. Applications in food analysis were also examined.  相似文献   

13.
Chen Y  Chen J  Ma K  Cao S  Chen X 《Analytica chimica acta》2007,605(2):185-191
A sensitive fluorimetric method for determination of phytic acid in human urine samples was described. The method was based on a fluorimetric replacement reaction, in which the added phytic acid replaced the Cu2+ ion from Cu2+-gelatin complex, liberating the fluorescent gelatin molecule. The fluorescence of the solution was accordingly recovered proportionally to the amount of the foreign phytic acid. The excitation wavelength was 273.5 nm and the characteristic emission wavelength was 305.0 nm, respectively. The calibration graph was obtained by plotting the recovered fluorescent intensity at maximum 305.0 nm against the added standard phytic acid, and was divided into two sections. One section was linear over the range of 0.40-2.40 mg L−1 with a linear regression equation of If = −0.895 + 15.146c (R2 > 0.9993), and the other over the range of 2.40-9.20 mg L−1 with a linear regression equation of If = −29.526 + 26.113c (R2 > 0.9996), respectively. The relative standard deviation (R.S.D.) at 95% confidence degree for a 2.0 mg L−1 of standard phytic acid within 1 month was less than 1.26% (n = 5), indicating the procedure is reproducible. The detection and the quantification limits of phytic acid were estimated to be 0.23 and 0.40 mg L−1, respectively. The proposed method was applied to the determination of phytic acid in urine samples and the found concentrations of phytic acid in urine were in the range of 0.49-0.75 mg L−1 with recoveries of 96.2-108.8%. Comparison of the obtained results with the reported HPLC was performed, indicating the proposed method was reliable.  相似文献   

14.
Liu Y  Liang P  Guo L 《Talanta》2005,68(1):25-30
Nanometer titanium dioxide immobilized on silica gel (immobilized nanometer TiO2) was prepared by sol-gel method and characterized by using X-ray diffraction (XRD) and scanning electron microscope (SEM). The adsorptive potential of immobilized nanometer TiO2 for the preconcentration of trace Cd, Cr, Cu and Mn was assessed in this work. The metal ions studied can be quantitative retained at a pH range of 8-9, and 0.5 mol L−1 HNO3 was sufficient for complete elution. The adsorption capacity of immobilized nanometer TiO2 for Cd, Cr, Cu and Mn was found to be 2.93, 2.11, 6.69 and 2.47 mg g−1, respectively. A new method using a microcolumn packed with immobilized nanometer TiO2 as sorbent has been developed for the preconcentration of trace amounts of Cd, Cr, Cu and Mn prior to their determination by inductively coupled plasma atomic emission spectrometry (ICP-AES). The method has been successfully applied for the determination of trace elements in some environmental samples with satisfactory results.  相似文献   

15.
The presence of trace neutral organonitrogen compounds as carbazole and indole in derivative petroleum fuels plays an important role in the car's engine maintenance. In addition, these substances contribute to the environmental contamination and their control is necessary because most of them are potentially carcinogenic and mutagenic. For those reasons, a reliable and sensitive method was proposed for the determination of neutral nitrogen compounds in fuel samples, such as gasoline and diesel using preconcentration with modified silica gel (Merck 70-230 mesh ASTM) followed by differential pulse voltammetry (DPV) technique on a glassy carbon electrode. The electrochemical behavior of carbazole and indole studied by cyclic voltammetry (CV) suggests that their reduction occurs via a reversible electron transfer followed by an irreversible chemical reaction. Very well resolved diffusion controlled voltammetric peaks were obtained in dimethylformamide (DMF) with tetrabutylammonium tetrafluoroborate (TBAF4 0.1 mol L−1) for indole (−2.27 V) and carbazole (−2.67 V) versus Ag|AgCl|KClsat reference electrode. The proposed DPV method showed a good linear response range from 0.10 to 300 mg L−1 and a limit of detection (L.O.D) of 7.48 and 2.66 μg L−1 for indole and carbazole, respectively. The results showed that simultaneous determination of indole and carbazole presents in spiked gasoline samples were 15.8 ± 0.3 and 64.6 ± 0.9 mg L−1 and in spiked diesel samples were 9.29 ± 1 and 142 ± 1 mg L−1, respectively. The recovery was evaluated and the results shown the values of 88.9 ± 0.4 and 90.2 ± 0.8% for carbazole and indole in fuel determinations. The proposed method was also compared with UV-vis spectrophotometric measures and the results obtained for the two methods were in good agreement according to the F and t Student's tests.  相似文献   

16.
Thanyarat Chuesaard 《Talanta》2009,79(4):1181-1187
An interfacing has been developed to connect a spectrophotometer with a personal computer and used as a readout system for development of a simple, rapid and sensitive reversed flow injection (rFI) procedure for chlorate determination. The method is based on the oxidation of indigo carmine by chlorate ions in an acidic solution (dil. HCl) leading to the decrease in absorbance at 610 nm. The decrease in absorbance is directly related to the chlorate concentration present in the sample solutions. Optimum conditions for chlorate were examined. A linear calibration graph over the range of 0.1-0.5 mg L−1 chlorate was established with the regression equation of Y = 104.5X + 1.0, r2 = 0.9961 (n = 6). The detection limit (3σ) of 0.03 mg L−1, the limit of quantitation (10σ) of 0.10 mg L−1 and the RSD of 3.2% for 0.3 mg L−1 chlorate (n = 11) together with a sample throughput of 92 h−1 were obtained. The recovery of the added chlorate in spiked water samples was 98.5 ± 3.1%. Major interferences for chlorate determination were found to be BrO3, ClO2, ClO and IO3 which were overcome by using SO32− (as Na2SO3) as masking agent. The method has been successfully applied for the determination of chlorate in spiked water samples with the minimum reagent consumption of 14.0 mL h−1. Good agreement between the proposed rFIA and the reference methods was found verified by Student's t-test at 95% confidence level.  相似文献   

17.
We report about the use of carbon paste electrode modified with kaolinite for analytical detection of trace lead(II) in domestic water by differential pulse voltammetry. Kaolinite clay was modified with tripolyphosphate (TPP) by impregnation method. The results show that TPP in kaolinite clay plays an important role in the accumulation process of Pb(II) on the modified electrode surface. The electroanalytical procedure for determination of Pb(II) comprised two steps: chemical accumulation of the analyte under open-circuit conditions, followed by electrochemical detection of the pre-concentrated species using differential pulse voltammetry. The analytical performance of this system has been explored by studying the effects of preconcentration time, carbon paste composition, pH, supporting electrolyte concentration, as well as interferences due to other ions. The calculated detection limit based on the variability of a blank solution (3sb criterion) for 10 measurements was 8.4 × 10−8 mol L−1, and the sensitivity determined from the slope of the calibration graph was 0.910 mol L−1. The reproducibility (RSD) for five replicate measurements at 1.0 mg L−1 lead level was 1.6%. The results indicate that this electrode is sensitive and effective for the determination of Pb2+.  相似文献   

18.
The paper presents a new method for a simultaneous determination of inorganic nitrogen species in the oxidized (NO2, NO3) and reduced (NH4+) form in rain water samples. The method is based on a system of nitrogen species separation employing ion exchange and diode-array detection. The ions are separated in a strong ion-exchanger, nitrites and nitrates are determined directly at 208 and 205 nm, respectively, while the ammonium ions are determined in the column hold-up time after a post-column derivatization by the Nessler reagent, at 425 nm. The use of a diode-array detector permits a simultaneous identification of the inorganic nitrogen species in 8 min. The detection limits obtained are: NO2, 0.1 mg L−1; NO3, 0.05 mg L−1; NH4+, 1 mg L−1. The method proposed has been successfully used for speciation analysis of inorganic nitrogen in precipitation.  相似文献   

19.
A photocatalytic degradation method was developed for polychlorobiphenyl (PCB) and organochloride pesticide (OCP) discrimination and quantification. A mixture of Aroclor 1260 and p,p′-DDT was irradiated at 254 nm by UV lamp (40 W) in the presence of TiO2 (30 mg mL−1 non-aqueous solution). Comparison of gas chromatograms showed that p,p′-DDT signals decreased significantly after irradiation, while Aroclor 1260s chromatograms did not show any difference before and after irradiation. Detection limits were 0.30 mg L−1 and 0.15 mg L−1 for p,p′-DDT and Aroclor 1260, respectively. The method was applied to spiked egg samples, the recoveries were found as 72% for DDT and 82.01% for Aroclor 1260.  相似文献   

20.
A novel, simple and green procedure is presented for the determination of boron. The method is based on ultrasound-assisted conversion of boron to tetrafluoroborate anion and the formation of an ion pair between BF4 and Astra Phloxine reagent (R), followed by dispersive liquid-liquid microextraction of the ion pair formed and subsequent UV-vis spectrophotometric detection. The conversion of boron to tetrafluoroborate anion is performed in an acidic medium of 0.9 mol L−1 H2SO4 in the presence of 0.1 mol L−1 F- by means of 10 min of ultrasonication. The extraction of the ion pair formed between BF4 and R (1 × 10−4 mol L−1 R) is carried out by dispersive liquid-liquid microextraction using 0.5 mL of amyl acetate (as extraction solvent), tetrachloromethane (as auxiliary solvent) and acetonitrile (as dispersive solvent) in a ratio of 1:1:2. The absorbance of the coloured extracts obeys Beer's law in the range 0.22-18.7 mg L−1 of B(III) at 553 nm wavelength. The limit of detection calculated from a blank test (n = 10) based on 3 s is 0.015 mg L−1 of B(III). The method was applied to the determination of boron in mineral waters.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号