1.
A multi-pumping flow system (MPFS) for the spectrophotometric determination of dissolved orthophosphate and dissolved organic phosphorus in wastewater samples is proposed. The determination of orthophosphate is based on the vanadomolybdate method. In-line ultraviolet photo-oxidation is employed to mineralise organic phosphorus to orthophosphate prior to detection. A solenoid valve allows the deviation of the flow towards the UV-lamp to carry out the determination of organic phosphorus.Calibration was found to be linear up to 20 mg P L−1, with a detection limit (3sb/S) of 0.08 mg P L−1, an injection throughput of 75 injections h−1 and a repeatability (R.S.D.) of 0.6% for the direct determination of orthophosphate. On the other hand, calibration graphs were linear up to 40 mg P L−1, with a detection limit (3sb/S) of 0.5 mg P L−1, an injection throughput of 11 injections h−1 and a repeatability (R.S.D.) inferior to 2.3% for the procedures involving UV photo-oxidation.  相似文献   

2.
Melchert WR  Rocha FR 《Talanta》2005,65(2):461-465
Nitrate determination in waters is generally carried out with cadmium filings and carcinogenic reagents or by reaction with phenolic compounds in highly concentrated sulfuric acid medium. In this work, it was developed a green analytical procedure for nitrate determination in natural waters based on direct spectrophotometric measurements in ultraviolet, using a flow-injection system with an anion-exchange column for separation of nitrate from interfering species. The proposed method employs only one reagent (HClO4) in a minimum amount (equivalent to 18 μL concentrated acid per determination), and allowed nitrate determination within 0.50-25.0 mg L−1, without interference of up to 200.0 mg L−1 humic acid; 1.0 mg L−1 NO2; 200.0 mg L−1 PO43−; 75.0 mg L−1 Cl; 50.0 mg L−1 SO42− and 15.0 mg L−1 Fe3+. The detection limit (99.7% confidence level) and the coefficient of variation (n = 20) were estimated as 0.1 mg L−1 and 0.7%, respectively. The results obtained for natural water samples were in agreement with those achieved by the reference method based on nitrate reduction with copperized cadmium at the 95% confidence level.  相似文献   

3.
A vapor generation procedure to determine Cd by atomic fluorescence spectrometry (AFS) has been established. Volatile species of Cd are generated by following reaction of acidified sample containing Fe(II) and l-cysteine (Cys) with sodium tetrahydroborate (NaBH4). The presence of 5 mg L−1 Fe(II) and 0.05% m/v Cys improves the efficiency of Cd vapor generation substantially about four-fold compared with conventional thiourea and Co(II) system. Three experiments with different mixing sequences and reaction times are designed to study the reaction mechanism. The results document that the stability of Cd(II)–Cys complexes is better than Cys–THB complexes (THB means NaBH4) while the Cys–THB complexes have more contribution to improve the Cd vapor generation efficiency than Cd(II)–Cys complexes. Meanwhile, the adding of Fe(II) can catalyze the Cd vapor generation. Under the optimized conditions, the detection limit of Cd is 0.012 μg L−1; relative standard deviations vary between 0.8% and 5.5% for replicate measurements of the standard solution. In the presence of 0.01% DDTC, Cu(II), Pb(II) and Zn(II) have no significant influence up to 5 mg L−1, 10 mg L−1and 10 mg L−1, respectively. The accuracy of the method is verified through analysis of the certificated reference materials and the proposed method has been applied in the determination of Cd in seafood and rice samples.  相似文献   

4.
A sequential injection analysis (SIA) using lab-on-valve with air segmentation and spectrophotometric detection was designed for copper(II) determination. It is based on the reaction of copper(II) and 2-carboxy-2′-hydroxy-5′-sulfoformazyl benzene (Zincon) in a weak alkaline solution between the air zones. Beer's Law was obeyed over the range of 0.1-2.0 mg L−1 copper(II) with a correlation coefficient 0.9985 and a slope of 0.2893 absorbance unit/mg L−1. The relative standard deviation was 2.0% for a series of 10 measurements of 0.5 mg L−1 copper(II) solution. The detection limit (3 S/N) and the limit of quantification (LOQ) were 0.05 and 0.17 mg L−1 respectively. This method has been successfully applied to determination of copper(II) in wastewater with a sample throughput of 120 h−1. The method is superior to the batchwise method in that it provides fully automation, rapidity, less reagents and sample consumption with little waste generation.  相似文献   

5.
A simple, specific and sensitive sequential injection analysis (SIA) system based on non-immunoassay fluorescent detection has been developed for the determination of urinary albumin. The specific binding of the dye Albumin Blue 580 (AB 580) to albumin in urine generated high emission fluorescent signals. The excitation and emission wavelengths were set at 590 and 610 nm, respectively. The analytical range was obtained from 1 to 100 mg L−1, with a detection limit of 0.3 mg L−1 (S/N = 3). The SIA system gave high precision with relative standard deviations (R.S.D.s) of 0.9% and 1.4% when evaluated with 15 and 100 mg L−1 albumin (n = 15), respectively. The method exhibited good reproducibility, as assessed by performing four analytical curves on different days, and intra-run CVs (2.3-3.3%) and inter-run CVs (3.8%) were obtained. Rapid operation was achieved with a sample throughput of 37 h−1. This method was successfully applied to the determination of urinary albumin, and the method was highly correlated with the immunoturbidimetric method (r2 = 0.965; n = 72).  相似文献   

6.
A new procedure for determination of biogenic amines (BA): histamine, phenethylamine, tyramine and tryptamine, based on the derivatization reaction with 2-chloro-1,3-dinitro-5-(trifluoromethyl)-benzene (CNBF), is proposed. The amines derivatives with CNBF were isolated and characterized by X-ray crystallography and 1H, 13C, 19F NMR spectroscopy in solution. The novelty of the procedure is based on the pure and well-characterized products of the amines derivatization reaction. The method was applied for the simultaneous analysis of the above mentioned biogenic amines in wine samples by the reversed phase-high performance liquid chromatography. The procedure revealed correlation coefficients (R2) between 0.9997 and 0.9999, and linear range: 0.10–9.00 mg L−1 (histamine); 0.10–9.36 mg L-1 (tyramine); 0.09–8.64 mg L−1 (tryptamine) and 0.10–8.64 mg L−1 (phenethylamine), whereas accuracy was 97%–102% (recovery test). Detection limit of biogenic amines in wine samples was 0.02–0.03 mg L−1, whereas quantification limit ranged 0.05–0.10 mg L−1. The variation coefficients for the analyzed amines ranged between 0.49% and 3.92%. Obtained BA derivatives enhanced separation the analytes on chromatograms due to the inhibition of hydrolysis reaction and the reduction of by-products formation.  相似文献   

7.
An autonomous multi-parameter flow-through CO2 system has been developed to simultaneously measure surface seawater pH, carbon dioxide fugacity (fCO2), and total dissolved inorganic carbon (DIC). All three measurements are based on spectrophotometric determinations of solution pH at multiple wavelengths using sulfonephthalein indicators. The pH optical cell is machined from a PEEK polymer rod bearing a bore-hole with an optical pathlength of ∼15 cm. The fCO2 optical cell consists of Teflon AF 2400 (DuPont) capillary tubing sealed within the bore-hole of a PEEK rod. This Teflon AF tubing is filled with a standard indicator solution with a fixed total alkalinity, and forms a liquid core waveguide (LCW). The LCW functions as both a long pathlength (∼15 cm) optical cell and a membrane that equilibrates the internal standard solution with external seawater. fCO2 is then determined by measuring the pH of the internal solution. DIC is measured by determining the pH of standard internal solutions in equilibrium with seawater that has been acidified to convert all forms of DIC to CO2. The system runs repetitive measurement cycles with a sampling frequency of ∼7 samples (21 measurements) per hour. The system was used for underway measurements of sea surface pH, fCO2, and DIC during the CLIVAR/CO2 A16S cruise in the South Atlantic Ocean in 2005. The field precisions were evaluated to be 0.0008 units for pH, 0.9 μatm for fCO2, and 2.4 μmol kg−1 for DIC. These field precisions are close to those obtained in the laboratory. Direct comparison of our measurements and measurements obtained using established standard methods revealed that the system achieved field agreements of 0.0012 ± 0.0042 units for pH, 1.0 ± 2.5 μatm for fCO2, and 2.2 ± 6.0 μmol kg−1 for DIC. This system integrates spectrophotometric measurements of multiple CO2 parameters into a single package suitable for observations of both seawater and freshwater.  相似文献   

8.
A suitable non-enzymatic method is presented as an alternative to the lactic acid determination in yogurt and fermented mash samples. The oxidative conversion of lactic acid by Ce4+ to CO2 was performed in a sequential injection system with a heating coil set at 45 °C. A gas diffusion unit was coupled to the flow system for promoting the permeation of CO2, which was collected into a bromothymol blue solution (pH 8.4), used as indicator solution for the spectrophotometric determination (619 nm). Simplicity in operation, low reagent consumption, low cost and ruggedness are some remarkable characteristics of the proposed system. Base line drift was < 0.005 h− 1. A linear range from 20.0 to 100.0 mg L− 1 lactic acid was obtained (r2 = 0.998), and the detection and quantification limits were estimated as 0.158 mg L− 1 and 1.6 mg L− 1, respectively. The sampling rate was 22 h− 1, with a consumption of 0.04 g Ce4+ per determination. Interferences of matrix components were not detected. Samples of yogurt and sugar cane fermented mash products were analyzed, and no significant difference at 95% confidence level was observed when comparing the proposed method with HPLC analysis.  相似文献   

9.
A simple, automatic and practical system for successive determination of albumin and creatinine has been developed by combining sequential injection analysis (SIA) and highly sensitive dye-binding assays. Albumin detection was based on the increase in the absorbance due to complex formation between albumin and eosin Y in acidic media. The absorbance of the complex was monitored at 547 nm. For the creatinine assay, the concentration of creatinine was measured by reaction with alkaline picrate to form a colored product which absorbs at 500 nm. The influences of experimental variables such as effects of pH, reagent concentration, standard/sample volume and interferences were investigated. Under optimal conditions, the automated method showed linearity up to 20 mg L−1 for albumin and 100 mg L−1 for creatinine. The 3σ detection limits were 0.6 and 3.5 mg L−1 for albumin and creatinine, respectively, and the relative standard deviations (n = 10) were 2.49% for 20 mg L−1 albumin, and 3.14% for 20 mg L−1 creatinine. Application of the proposed method to the direct analysis of urinary samples yielded results which agreed with those obtained from the Bradford protein assay and a creatinine enzymatic assay according to a paired t-test. The results obtained should be a step towards developing a fully automated and reliable analytical system for clinical research, which requires direct determination of albumin and creatinine and/or its ratios.  相似文献   

10.
New methods have been developed and applied successfully for the determination of dissolved inorganic, organic and total carbon in water samples. The new methods utilize two instrumental setups, Reagent-Free™ Ion Chromatography (RF™-IC) and inductively coupled plasma atomic emission spectrometry (ICP-AES). Dissolved inorganic carbon (DIC) was measured in untreated samples along with Cl, F and SO42− using RF™-IC and by in-line mixing with 0.1 M HNO3 to enhance CO2 removal in the nebulizer, followed by ICP-AES analysis. Total dissolved carbon (TDC) was measured by in-line mixing with 0.1 M NaOH following ICP-AES analysis. Dissolved organic carbon (DOC) was obtained as the difference between DIC and TDC. Only non-volatile organic carbon could be detected by the present method. The workable limits of detection obtained in the present study were 0.5 mM (RF™-IC) and 0.1 mM (ICP-AES) for dissolved inorganic and organic carbon, respectively. The power of the new methods lies in routine analysis of DIC and DOC in samples of natural waters of variable composition and salinity using analytical techniques and facilities available in most laboratories doing water sample analysis. The techniques are sensitive and precise, can be automated using gas-tight sample vials and auto-samplers, and are independent of most elemental interferences with the exception of chloride overload by saline samples when using RF™-IC. The new methods were successfully applied for analysis of DIC and DOC in selected samples of natural and synthetic waters.  相似文献   

11.
Potassium formate was extracted from airport storm water runoff by headspace solid-phase microextraction (HS-SPME) and analyzed by GC–MS. Formate was transformed to formic acid by adding phosphoric acid. Subsequently, formic acid was derivatized to methyl formate by adding methanol. Using sodium [2H]formate (formate-d) as an internal standard, the relative standard deviation of the peak area ratio of formate (m/z 60) and formate-d (m/z 61) was 0.6% at a concentration of 208.5 mg L−1. Calibration was linear in the range of 0.5–208.5 mg L−1. The detection limit calculated considering the blank value was 0.176 mg L−1. The mean concentration of potassium formate in airport storm water runoff collected after surface de-icing operations was 86.9 mg L−1 (n = 11) with concentrations ranging from 15.1 mg L−1 to 228.6 mg L−1.  相似文献   

12.
In this study, a multiwavelength UV spectral deconvolution (UVSD) procedure is proposed as a robust and simple procedure for direct estimation of carbon and nitrate contents in soil water extracts. Soil samples were collected from an open-air field cultivated with maize at 3 different depths, 30 cm each, between 0 and 90 cm of soil surface during a period of 7 months. Fractionation of water extractable organic carbon (WEOC) into hydrophobic (Hpo-WEOC), transphilic (Tpi-WEOC), and hydrophilic (Hpi-WEOC) fractions is performed using XAD-8 and XAD-4 resins connected in series. In order to perform UVSD, 3 representative reference spectra of WEOC fractions were selected automatically, in addition to a 4th spectrum representative of NO3 selected manually in order to compose the deconvolution basis. The restitution of UV spectra was made in the range 235-350 nm. Through exploitation of soil water extract UV spectra, it was possible in a single-step deconvolution procedure to determine the organic carbon (mg C l−1) and NO3 (mg l−1) concentrations and to differentiate and to quantitatively estimate carbon content of WEOC fractions. Statistical tests indicated satisfactory correlations between values estimated using UVSD and those determined by conventional reference methods for each parameter determined. The ranges of concentrations of carbon and NO3 in the soil water extracts studied are between 3.00 and 15.00 mg C l−1 and 60-300 mg l−1, respectively. The limits of quantification (LQ) and of detection (LD) of WEOC and NO3 were found to be 0.10 and 0.05 mg C l−1, and 0.10 and 0.03 mg l−1, respectively.  相似文献   

13.
In the present study, an analytical procedure was developed for the determination of short-chain fatty acids (SCFAs) in landfill leachate and municipal wastewater employing injection of aqueous samples to gas chromatograph with flame ionization detector (GC-FID). Chromatographic conditions such as a separation system, injection volume, oven temperature program were investigated and selected. With two columns, one with a polar (polyethylene glycol) and one with a non-polar (dimethylpolisiloxane) stationary phase, good separation of SCFAs, containing from 2 to 8 carbon atoms, was achieved. The sample volume was 2 μL and the temperature program 80 °C (30 s) then 7 °C min−1 to 220 °C (2 min). LOQs values were below 0.25 mg L−1. The concentrations of the acids in the landfill leachate studied ranged from 0.45 ± 0,059 (average ± extended uncertainty) mg L−1 for pentanoic acid to 15.2 ± 0.73 mg L−1 for ethanoic acid. Concentrations of SCFAs in the municipal wastewater were lower than LOQs.  相似文献   

14.
Zhou R  Luo W  Zhu L  Chen F  Tang H 《Analytica chimica acta》2007,597(2):295-299
Ultrasonic oxidation of iodide was investigated in the presence of carbon tetrachloride (CCl4). The ultrasonic oxidation of potassium iodide led to formation of iodine and then I3 in the presence of excess iodide, and the generated I3 shows strong UV absorption with a molar absorptivity of 2.31 × 104 L mol−1 cm−1 at the maximum absorption wavelength of 351 nm. The ultrasonic oxidation of iodide was found to be significantly promoted by a small addition of CCl4, and it was further found that the generation rate was increased with the amount of CCl4 added. This can be used to analyze the level of CCl4 dissolved in aqueous solutions. Under optimum conditions, the concentration of generated iodine (or its absorption at 351 nm) was found to correlated linearly with the concentration of CCl4 in the range of 0.2-50 mg L−1 (detection limit = 0.09 mg L−1, R2 = 0.999). As an alternative indirect spectrophotometric method of CCl4 determination, the proposed method was successfully applied to determine the concentrations of CCl4 in several practical samples, showing merits of being sensitive and simple of operation.  相似文献   

15.
Zhu L  Chen Y  Wu Y  Li X  Tang H 《Analytica chimica acta》2006,571(2):242-247
A new method for chemical oxygen demand (COD) determination has been developed, based on photocatalytic oxidative degradation by using a fluorinated-TiO2-KMnO4 system. In such a system, a linear correlation is observed between the amount of oxidizable dissolved organic matter and the amount of MnO4 consumed by the coupled reduction process. Thus, the COD determination is transformed to a simple and direct determination of the deletion of MnO4. The surface fluorination of TiO2 nanoparticles can enhance the rate of photocatalytic oxidation of organic matter and the rate of coupled photocatalytic reduction of MnO4. This makes the method be rapid, environment friendly and easy for operation. Under optimized conditions, this method can respond linearly to COD of potassium hydrogen phthalate (KHP) in the range of 0.1-280 mg L−1, with a detection limit of 0.02 mg L−1 COD. The COD in samples of tap water, lake water and paper industry sewage has been determined satisfactorily by using this method.  相似文献   

16.
Hydrogen peroxide and nicotinamide adenine dinucleotide (NADH) may be determined amperometrically using screen-printed electrodes chemically modified with iron(III) hexacyanoosmate(II) (Osmium purple) in flow injection analysis (FIA). The determination is based on the exploitation of catalytic currents resulting from the oxidation/reduction of the modifier. The performance of the sensor was characterized and optimized by controlling several operational parameters (applied potential, pH and flow rate of the phosphate buffer). Comparison has been made with analogous complexes of ruthenium (Ruthenium purple) and iron (Prussian blue). Taking into account the sensitivity and stability of corresponding sensors, the best results were obtained with the use of Osmium purple. The sensor exhibited a linear increase of the amperometric signal with the concentration of hydrogen peroxide in the range of 0.1-100 mg L−1 with a detection limit (evaluated as 3σ) of 0.024 mg L−1 with a R.S.D. 1.5% for 10 mg L−1 H2O2 under optimized flow rate of 0.4 mL min−1 in 0.1 M phosphate buffer carrier (pH 6) and a working potential of +0.15 V versus Ag/AgCl. Afterwards, a biological recognition element - either glucose oxidase or ethanol dehydrogenase - was incorporated to achieve a sensor facilitating the determination of glucose or ethanol, respectively. The glucose sensor gave linearity between current and concentration in the range from 1 to 250 mg L−1 with a R.S.D. 2.4% for 100 mg L−1 glucose, detection limit 0.02 mg L−1 (3σ) and retained its original activity after 3 weeks when stored at 6 °C. Optimal parameters in the determination of ethanol were selected as: applied potential +0.45 V versus Ag/AgCl, flow rate 0.2 mL min−1 in 0.1 M phosphate buffer carrier (pH 7). Different structural designs of the ethanol sensor were tested and linearity obtained was up to 1000 mg L−1 with a maximum R.S.D. of 5.1%. Applications in food analysis were also examined.  相似文献   

17.
A novel one-step sample preparation technique called ultrasound-assisted matrix solid-phase dispersive liquid extraction was developed. After sample matrices being dispersed, target analytes were extracted into acid solutions and fat and lipin were dissolved in n-hexane while the interfering components were retained by dispersing sorbent. The extraction process could be rapidly accomplished within 9 min with high sample throughput under the synergistic effects of vibration, ultrasound action and heating. The extraction efficiency of approach was demonstrated for the determination of intermediates in commercial hair dyes with ion chromatography. Linearity ranges of 0.2–100 mg L−1 and detection limits varying from 0.019 to 0.048 mg L−1 were achieved. The recoveries ranged from 85.7 to 107.0% with the relative standard deviations (RSDs) of 0.31–3.7%. These results showed that the method was simple, time-saving, reliable and suitable for the routine analysis of intermediates in large numbers of hair dyes.  相似文献   

18.
In the present paper, the TiO2 nanorod arrays electrode was developed as a sensor for the determination of chemical oxygen demand (COD) based on a photoelectrochemical degradation principle. Effects of common parameters, such as applied potential, light intensity and pH on its analytical performance were investigated. Under the optimized conditions, the nanorod arrays electrode was successfully applied in the COD determination for both synthetic and real samples. In the COD determination, the proposed method can achieve a practical detection limit of 18.3 mg L−1 and a linear range of 20–280 mg L−1. Furthermore, the results obtained by the proposed method were well correlated with those obtained using the conventional (i.e., dichromate) COD determination method. The main advantages of this COD determination method were its simplicity, long term stability and environmental friendly (corrosive and toxic reagents not consumed). This work would open a new application area (COD determination) of the TiO2 nanorod arrays.  相似文献   

19.
Three adsorbents (Chelex-100, manganese dioxide [MnO2] and Metsorb), used as binding layers with the diffusive gradient in thin film (DGT) technique, were evaluated for the measurement of inorganic uranium species in synthetic and natural waters. Uranium (U) was found to be quantitatively accumulated in solution (10–100 μg L−1) by all three adsorbents (uptake efficiencies of 80–99%) with elution efficiencies of 80% (Chelex-100), 84% (MnO2) and 83% (Metsorb). Consistent uptake occurred over pH (5–9), with only MnO2 affected by pH < 5, and ionic strength (0.001–1 mol L−1 NaNO3) ranges typical of natural waters, including seawater. DGT validation experiments (5 days) gave linear mass uptake over time (R2 ≥ 0.97) for all three adsorbents in low ionic strength solution (0.01 M NaNO3). Validation experiments in artificial sea water gave linear mass uptake for Metsorb (R2 ≥ 0.9954) up to 12 h and MnO2 (R2 ≥ 0.9259) up to 24 h. Chelex-100 demonstrated no linear mass uptake in artificial sea water after 8 h. Possible interferences were investigated with SO42− (0.02–200 mg L−1) having little affect on any of the three DGT binding layers. PO43− additions (5 μg L−1–5 mg L−1) interfered by forming anionic uranyl phosphate complexes that Chelex-100 was unable to accumulate, or by directly competing with the uranyl species for binding sites, as with MnO2 and the Metsorb. HCO3 (0.1–500 mg L−1) additions formed anionic species which interfered with the performance of the Chelex-100 and the MnO2, and the Ca2+ (0.1–500 mg L−1) had the affect of forming labile calcium uranyl species which aided uptake of U by all three resins. DGT field deployments in sea water (Southampton Water, UK) gave a linear mass uptake of U over time with Metsorb and MnO2 (4 days). Field deployments in fresh water (River Lambourn, UK) gave linear uptake for up to 7 and 4 days for Metsorb and MnO2 respectively. Field deployment of the Metsorb-DGT samplers with various diffusive layer thicknesses (0.015–0.175 cm) allowed accurate measurements of the diffusive boundary layer (DBL) and allowed DBL corrected concentrations to be determined. This DBL-corrected U concentration was half that determined when the effect of the DBL was not considered. The ability of the DGT devices to measure U isotopic ratios with no isotopic fractionation was shown by all three resins, thereby proving the usefulness of the technique for environmental monitoring purposes.  相似文献   

20.
Silva SG  Rocha FR 《Talanta》2010,83(2):559-564
A flow system designed with solenoid micro-pumps is proposed for fast and greener spectrophotometric determination of free glycerol in biodiesel. Glycerol was extracted from samples without using organic solvents. The determination involves glycerol oxidation by periodate, yielding formaldehyde followed by formation of the colored (3,5-diacetil-1,4-dihidrolutidine) product upon reaction with acetylacetone. The coefficient of variation, sampling rate and detection limit were estimated as 1.5% (20.0 mg L−1 glycerol, n = 10), 34 h−1, and 1.0 mg L−1 (99.7% confidence level), respectively. A linear response was observed from 5 to 50 mg L−1, with reagent consumption estimated as 345 μg of KIO4 and 15 mg of acetylacetone per determination. The procedure was successfully applied to the analysis of biodiesel samples and the results agreed with the batch reference method at the 95% confidence level.  相似文献   