首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
A rapid, selective and sensitive method using UPLC‐MS/MS was first developed and validated for quantitative analysis of koumine in rat plasma. A one‐step protein precipitation with methanol was employed as a sample preparation technique. Plasma samples were separated on an Acquity UPLC BEH C18 column (50 × 2.1 mm, i.d. 1.7 µm) with a gradient mobile phase consisting of methanol with 0.1% (v/v) formic acid and water containing 0.1% (v/v) formic acid at a flow rate of 0.3 mL/min. Detection and quantification were performed on a triple quadrupole tandem mass spectrometer by multiple reaction monitoring mode via positive eletrospray ionization. Good linearity (r > 0.9997) was achieved using weighted (1/x2) least squares linear regression over a concentration range of 0.025–15 µg/mL with a lower limit of quantification of 0.025 µg/mL for koumine. The intra‐ and inter‐ precisions (relative standard deviation) of the assay at all three quality control samples were 5.6–14.1% with an accuracy (relative error) of 5.0–14.0%, which meets the requirements of the US Food and Drug Administration guidance. This developed method was successfully applied to an in vivo pharmacokinetic study in rats after a single intravenous dose of 20 mg/kg koumine. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

2.
A novel UPLC‐DAD method was developed and validated for the simultaneous determination of baicalin (baicalein‐7‐glucuronide, BG), oroxylin A‐7‐O‐glucuronide (OAG) and wogonoside (WG) in rat plasma using rutin as the internal standard. Plasma samples were precipitated using acetonitrile containing 0.1% formic acid. Separation was performed on an Agilent Eclipse Plus C18 column (2.1 × 50 mm, 1.8 µm) using gradient acetonitrile and 0.2% formic acid water solution as mobile phase. The flow‐rate was set at 0.4 mL/min and the eluate was detected at 275 nm. The method was linear over the ranges of 0.075–17.50, 0.050–12.60 and 0.056–14.10 µg/mL for BG, OAG and WG, respectively. The intra‐ and inter‐day precisions were respectively <4.8% and 6.4%. All of the limits of detection of three analytes in rat plasma were 0.01 µg/mL, whereas the limits of quantification were, respectively, 0.035, 0.025 and, 0.025 µg/mL. This assay has been successfully applied to pharmacokinetics of BG, OAG and WG in rats after oral administration of Yinhuang granule (YHG) and comparative pharmacokinetics of BG in rats following oral administration of the pure BG, Radix Scutellariae (RS) or YHG. We speculate that some co‐existing ingredients in RS or YHG may increase the absorption and elimination of BG in rat. This work may be helpful for the quality control of Yinhuang granule. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

3.
A sensitive and specific ultra‐performance liquid chromatography–tandem mass spectrometry (UPLC‐MS‐MS) method for quantification of a newly developed anticancer agent NPD‐103 has been established. An aliquot of human plasma sample (200 µL) was spiked with 13C‐labeled paclitaxel (internal standard) and extracted with 1.3 mL of tert‐butyl methyl ether. NPD‐103 was quantitated on a C18 column with methanol–0.1% formic acid (75:25, v/v) as mobile phase using UPLC‐MS‐MS operating in positive electrospray ionization mode with a total run time of 3.0 min. For NPD‐103 at the concentrations of 1.0, 5.0 and 10.0 µg/mL in human plasma, the absolute extraction recoveries were 95.58, 102.43 and 97.77%, respectively. The linear quantification range of the method was 0.1–20.0 µg/mL in human plasma with linear correlation coefficients greater than 0.999. The intra‐ and inter‐day accuracy for NPD‐103 at 1.0, 5.0 and 10.0 µg/mL levels in human plasma fell into the ranges of 95.29–100.00% and 91.04–94.21%, and the intra‐ and inter‐day precisions were in the ranges of 8.96–11.79% and 7.25–10.63%, respectively. This assay is applied to determination of half‐life of NPD‐103 in human plasma. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

4.
The aim of the present study was to develop a simple, selective and reliable method to quantify acetaminophen and its toxic metabolite N‐acetyl‐p‐benzoquinoneimine (NAPQI) for pediatric studies using 100 µL plasma samples, by reverse‐phase HPLC and UV detection. The assay was performed using a C18 column and an isocratic elution with water–methanol–formic acid (70:30:0.15; v/v/v) as mobile phase. Linearity of the method was assayed in the range of 1–30 µg/mL for acetaminophen and 10–200 µg/mL for NAPQI, with a correlation coefficient r = 0.999 for both compounds, and inter‐ and intra‐day coefficients of variation of less than 13%. Several commonly co‐administered drugs were analyzed for selectivity and no interference with the determinations was observed. The detection and quantification limits for acetaminophen and NAPQI were 0.1 and 1 µg/mL, and 0.1 and 10 µg/mL respectively. The present method can be used to monitor acetaminophen levels using 100 µL plasma samples, which may be helpful when very small samples need to be analyzed, as in pharmacokinetics determination or drug monitoring in plasma in children. This assay is also able to detect the NAPQI for drug monitoring in patients diagnosed with acetaminophen intoxication. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

5.
A simple, rapid, selective and sensitive HPLC‐UV method has been developed and validated for the determination of ponicidin in rat plasma. The analyte was extracted from rat plasma by liquid–liquid extraction with ethyl acetate as the extraction solvent. The LC separation was performed on a Zorbax Eclipse XDB C18 analytical column (150 × 4.6 mm i.d., 5 µm) with an isocratic mobile phase consisting of methanol–water–phosphoric acid (45:55:0.01, v/v/v) at a flow rate of 1.0 mL/min. There was a good linearity over the range of 0.1–25 µg/mL (r = 0.9995) with a weighted (1/C2) least square method. The lower limit of quantification was proved to be 0.1 µg/mL. The accuracy was within ±10.0% in terms of relative error and the intra‐ and inter‐day precisions were less than 9.1% in terms of relative standard deviation. After validation, the method was successfully applied to characterize the pharmacokinetics of ponicidin in rats. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

6.
Evidence‐based herbal products with assured quality are assuming importance for complementary and alternative medicine. Traditional medicines by and large are not standardized and validated to meet the new requirements. In the present study, marker (embelin)‐based standardization of a major medicinal plant, Embelia ribes and its polyherbal formulations was attempted. Conditions for the quantitative extraction of the marker compound embelin from E. ribes fruits and herbal formulations were also optimized. Reversed‐phase high‐performance liquid chromatography, coupled with diode array detection (RP‐HPLC–DAD) for the quantification of embelin was developed and validated. Satisfactory results were obtained with respect to linearity (15–250 µg/mL), LOD (3.97 µg/mL), LOQ (13.2 µg/mL), recovery (99.4–103.8%) and precision (1.43–2.87%). The applicability of the method was demonstrated with selected phytopharmaceuticals. The present method was sensitive, accurate, simple and reproducible and therefore can be recommended for marker‐based standardization, and quality assurance of E. ribes herbal formulations. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

7.
A simple and sensitive method based on the combination of derivatization and high‐performance liquid chromatography with ultraviolet and fluorimetric detection was developed for the simultaneous determination of octreotide and gabexate mesylate metabolite in human pancreatic juice samples. Parameters of the derivatization procedure affecting extraction efficiency were optimized. The developed method was validated according to the International Conference on Harmonization guidelines. The calibration curves were linear over a range of 0.1–15 µg/mL for octreotide and 0.20‐15 µg/mL for gabexate mesylate metabolite. Derivatized products of octreotide and gabexate mesylate metabolite were separated on a Luna C18 column (4.6 × 250 mm; 5 µm particle size) using a gradient with a run time of 36 min, without further purification. The limits of detection were 0.025 and 0.05, respectively, for octreotide and gabexate mesylate metabolite. This paper reports the validation of a quantitative high performance liquid chromatography–photodiode array–fluorescence (HPLC‐PDA‐FL) method for the simultaneous analysis of octreotide and gabexate mesylate metabolite in pancreatic juice by protein precipitation using zinc sulfate–methanol–acetonitrile containing the derivatizing reagent, 4‐fluoro‐7‐nitro‐[2,1,3]‐benzoxadiazole (NBD‐F). Derivatized products of octreotide and gabexate mesylate metabolite were separated on a Luna C18 column (4.6 × 250 mm; 5 µm particle size) using a gradient with a run time of 36 min, without further purification. The method was validated over the concentration ranges 0.1–15 and 0.2–15 µg/mL for octreotide and gabexate mesylate metabolite, respectively, in human pancreatic juice. Biphalin and methyl‐p‐hydroxybenzoate were used as the internal standards. This method was successfully utilized to support clinical studies in humans. The results from assay validations show that the method is selective, sensitive and robust. The limit of quantification of the method was 0.1 µg/mL for octreotide and 0.2 µg/mL for gabexate mesylate metabolite, and matrix matched standard curves showed a good linearity up to 15 µg/mL. In the entire analytical range the intra‐ and inter‐day precision (RSD%) values were respectively ≤5.9% and ≤3.1% for octreotide and ≤2.0% and ≤3.9% for gabexate mesylate metabolite. For both analytes the intra‐ and inter‐day accuracy (bias) values ranged respectively from ?6.8 to –2.5% and from ?4.6 to ?5.7%. This method utilizes derivatization with NBD‐F and provides adequate sensitivity for both drugs. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

8.
Stellera chamaejasme L. has been used as a traditional Chinese medicine for the treatment of scabies, tinea, stubborn skin ulcers, chronic tracheitis, cancer and tuberculosis. A sensitive and selective ultra‐high liquid chromatography–tandem mass spectrometry (UPLC‐MS/MS) method was developed and validated for the simultaneous determination of five flavonoids (stelleranol, chamaechromone, neochamaejasmin A, chamaejasmine and isochamaejasmin) of S. chamaejasme L. in rat plasma. Chromatographic separation was accomplished on an Agilent Poroshell 120 EC‐C18 column (2.1 × 100 mm, 2.7 μm) with gradient elution at a flow rate of 0.4 mL/min and the total analysis time was 7 min. The analytes were detected using multiple reaction monitoring in positive ionization mode. The samples were prepared by liquid–liquid extraction with ethyl acetate. The UPLC‐MS/MS method was validated for specificity, linearity, sensitivity, accuracy and precision, recovery, matrix effect and stability. The validated method exhibited good linearity (r ≥ 0.9956), and the lower limits of quantification ranged from 0.51 to 0.64 ng/mL for five flavonoids. The intra‐ and inter‐day precision were both <10.2%, and the accuracy ranged from −11.79 to 9.21%. This method was successfully applied to a pharmacokinetic study of five flavonoids in rats after oral administration of ethyl acetate extract of S. chamaejasme L.  相似文献   

9.
Thymoquinone (THQ) is known for its neuroprotective and anti‐convulsant properties in preclinical studies. We herewith describe a simple, rapid, selective, sensitive and stability‐indicating UPLC method for the estimation of THQ and its application to biopharmaceutical studies such as in vitro release from nanoparticulate system and in vivo pharmacokinetic study. The method employed gradient elution using a Waters Acquity HSS‐T3 C18 (100 × 2.1 mm, 1.8 µm) UPLC column. The mobile phase consisted of water and acetonitrile, pumped at a flow rate of 0.5 mL/min. The injection volume was 5 µL and THQ was monitored at 294 nm wavelength with a total run time of 6 min. In solution as well as in plasma, the method was found to be linear (r ≥ 0.998), precise (CV ≤ 2.45%) and accurate (recovery ≥ 84.8%) in the selected concentration range of 0.1–0.8 µg/mL. Forced degradation studies revealed that THQ undergoes degradation under acidic, basic, oxidation and UV light stress conditions. However, the developed UPLC method could effectively resolve degradation product peaks from THQ. Further, no interference was found at the retention time of THQ from any plasma components, indicating selectivity of the developed method. For solutions, the limits of detection and quantitation of the method were found to be 0.001 and 0.0033 µg/mL, respectively; while in plasma they were 0.006 and 0.02 µg/mL, respectively. The validated method was successfully applied to quantify THQ in dissolution medium as well as oral in vivo pharmacokinetic study of THQ suspension and THQ‐ solid lipid nanoparticle (THQ‐SLN) formulation. A 2‐fold increase in the relative bioavailability was observed with the THQ‐SLN compared with THQ. The results indicate that the SLN significantly increased plasma concentrations and retention within the systemic circulation. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

10.
A rapid and highly selective liquid chromatography–tandem mass spectrometric (LC‐MS/MS) method for determination of polygalasaponin F (PF) in rat plasma was developed and validated. The chromatographic separation was achieved on a reverse‐phase Zorbax SB‐C18 column (150 × 4.6 mm, 5 µm), using 2 mm ammonium acetate (pH adjusted to 6.0 with acetic acid) and acetonitrile (25:75, v/v) as a mobile phase at 30 °C. MS/MS detection was performed using an electrospray ionization operating in positive ion multiple reaction monitoring mode by monitoring the ion transitions from m/z 1091.5 → 471.2 (PF) and m/z 700.4 → 235.4 (internal standard), respectively. The calibration curve showed a good linearity in the concentration range 0.0544–13.6 µg/mL, with a limit of quantification of 0.0544 µg/mL. The intra‐ and inter‐day precisions were <9.7% in rat plasma. The method was validated as per US Food and Drug Administration guidelines and successfully applied to pharmacokinetic study of PF in rats. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

11.
A simple, rapid and sensitive LC‐UV method was developed and validated for the determination of paclitaxel (PTX) in rabbit plasma and tissues. A 2 mL aliquot of acetonitrile and 10 μL ammonium acetate (pH 5.0, 6 m ) as extraction agents were used to markedly increase the extraction recoveries and greatly reduce the endogenous substances. The separation was achieved on a C18 column at 30 °C using an acetonitrile–ammonium acetate buffer (pH 5.0, 0.02 m ; 55:45, v/v) at a flow rate of 1.0 mL/min; UV detection was used at 227 nm. Good linearity was obtained between 0.025 and 10,000 µg/mL for plasma and between 0.025–200,000 µg/g for tissue samples (r > 0.999). The limit of detection was 6 ng/mL in plasma, 8 ng/g in heart and 12.5 ng/g in other tissues. The limit of quantitation was 25 ng/mL in plasma and heart, 125 ng/g in other tissues. The intra‐ and inter‐day assays of precision and accuracy for all bio‐samples ranged from 1.38 to 9.60% and from 83.6 to 114.5%, respectively. The extraction recoveries ranged from 70.1 to 109.5%. Samples were stable during three freeze–thaw cycles or stored in a freezer at ?20 °C for 30 days. The assay method was successfully applied to a study of the pharmacokinetics and tissue distribution of novel PTX lung targeting liposomes. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

12.
In this work, a sensitive and selective ultra‐performance liquid chromatography–tandem mass spectrometry (UPLC‐MS/MS) method for determination of hupehenine in rat plasma was developed and validated. After addition of imperialine as an internal standard (IS), protein precipitation by acetonitrile–methanol (9:1, v/v) was used to prepare samples. Chromatographic separation was achieved on a UPLC BEH C18 column (2.1 × 100 mm, 1.7 µm) with 0.1% formic acid and acetonitrile as the mobile phase with gradient elution. An electrospray ionization source was applied and operated in positive ion mode; multiple reaction monitoring mode was used for quantification using target fragment ions m/z 416.3 → 98.0 for hupehenine, and m/z 430.3 → 138.2 for IS. Calibration plots were linear throughout the range 2–2000 ng/mL for hupehenine in rat plasma. Mean recoveries of hupehenine in rat plasma ranged from 92.5 to 97.3%. Relative standard deviations of intra‐day and inter‐day precision were both <6%. The accuracy of the method was between 92.7 and 107.4%. The method was successfully applied to a pharmacokinetic study of hupehenine after either oral or intravenous administration. For the first time, the bioavailability of hupehenine was reported as 13.4%. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

13.
A simple and efficient liquid chromatography‐mass spectrometry (LC‐MS) method was developed and validated for simultaneous quantitation of catalpol and harpagide in normal and diabetic rat plasma. Protein precipitation extraction with acetonitrile was carried out using salidroside as the internal standard (IS). The LC separation was performed on an Elite C18 column (150 × 4.6 mm, 5 µm) with the mobile phase consisting of acetonitrile and water within a runtime of 12.0 min. The analytes were detected without endogenous interference in the selected ion monitoring mode with positive electrospray ionization. Calibration curves offered satisfactory linearity (r > 0.99) at linear range of 0.05–50.0 µg/mL for catalpol and 0.025–5.0 µg/mL for harpagide with the lower limits of quantitation of 0.05 and 0.025 µg/mL, respectively. Intra‐ and inter‐day precisions (RSD) were <9.4%, and accuracy (RE) was in the ?6.6 to 4.9% range. The extraction efficiencies of catalpol, harpagide and IS were all >76.5% and the matrix effects of the analytes ranged from 86.5 to 106.0%. The method was successfully applied to the pharmacokinetic study of catalpol and harpagide after oral administration of Zeng‐Ye‐Decoction to normal and diabetic rats, respectively. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

14.
A sensitive and selective liquid chromatography mass spectrometry method for determination of chidamide in rat plasma was developed. After addition of linezolid as internal standard, protein precipitation by acetonitrile–methanol (9:1, v/v) was used as sample preparation. Chromatographic separation was achieved on a Zorbax SB‐C18 (2.1 × 150 mm, 5 µm) column with acetonitrile–0.1% formic acid as mobile phase with gradient elution. An electrospray ionization source was applied and operated in positive ion mode; selective ion monitoring mode was used for quantification using target fragment ions m/z 391.5 for chidamide and m/z 338.5 for the IS. Calibration plots were linear over the range of 10–2000 ng/mL for chidamide in rat plasma. The lower limit of quantification for chidamide was 10 ng/mL. The mean recovery of chidamide in plasma was in the range of 86.6–92.1%. The coefficients of variation of intra‐day and inter‐day precision were both <12%. This method is simple and sensitive and was applied successfully in a pharmacokinetic study of chidamide to rats. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

15.
We describe a simple, rapid, selective and sensitive HPLC method coupled with fluorescence detection for simultaneous determination of 10 kinds of biogenic amines (BAs: tryptamine, 2‐phenethylamine, putrescine, cadaverine, histamine, 5‐hydroxytryptamine, tyramine, spermidine, dopamine and spermine). BAs and IS were derivated with dansyl chloride. Fluorescence detection (λex/λem = 340/510 nm) was used. A satisfactory result for method validation was obtained. The assay was shown to be linear over the ranges 0.005–1.0 μg/mL for tryptamine, 2‐phenethylamine and spermidine, 0.025–1.0 μg/mL for putrescine, 0.001–1.0 μg/mL for cadaverine, 0.25–20 μg/mL for histamine, 0.25–10 μg/mL for 5–hydroxytryptamine and dopamine, and 0.01–1.0 μg/mL for tyramine and spermine. The limits of detection and the limits of quantification were 0.3–75.0 ng/mL and 1.0–250.0 ng/mL, respectively. Relative standard deviations were ≤5.14% for intra‐day and ≤6.58% for inter‐day precision. The recoveries of BAs ranged from 79.11 to 114.26% after spiking standard solutions of BAs into a sample at three levels. Seven kinds of BAs were found in rat plasma, and the mean values of tryptamine, 2‐phenethylamine, putrescine, cadaverine, histamine, spermidine and spermine determined were 52.72 ± 7.34, 11.45 ± 1.56, 162.56 ± 6.26, 312.75 ± 18.11, 1306.50 ± 116.16, 273.89 ± 26.41 and 41.51 ± 2.07 ng/mL, respectively.  相似文献   

16.
A novel stability‐indicating reversed phase ultra‐high performance liquid chromatography (UPLC) coupled photodiode array gradient method was developed for determination of the nifedipine and related compounds. Furthermore, based on the chromatographic conditions and forced degradation studies performed through the development of the related substances method a UPLC isocratic method was validated for the determination of the assay of this active substance. An Acquity Shield RP18 (50 × 3.0 mm 1.7 µm) column was used for separation of nifedipine and its five potential impurities within 11 min, which is 5‐fold less than the official method. A mobile phase consisting of 10 mm ammonium formate (pH 4.5) and methanol, delivered at a flow rate 0.5 mL/min, was employed to achieve a minimum resolution of 2.0 for all consecutive pairs of compounds. The precision value expressed as percentage relative standard deviation for method repeatability and reproducibility was <5.0%. The recoveries for all the related compounds were in the range of 99–105.0%. Linearity was found to be acceptable over the concentration range of 0.25–1.5 µg/mL for nifedipine and its impurities. The limit of quantification for nifedipine was 0.05 µg/mL, which is much less than the European Pharmacopoeia method. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

17.
A simple, rapid, accurate and reproducible reverse‐phase HPLC method has been developed for the identification and quantification of two alkaloids ephedrine and cryptolepine in different extracts of Sida species using photodiode array detection. Baseline separation of the two alkaloids was achieved on a Waters RP‐18 X‐terra column (250 × 4.6 mm, 5 µm) using a solvent system consisting of a mixture of water containing 0.1% Trifluoroacetic acid (TFA) and acetonitrile in a gradient elution mode with detection at 210 and 280 nm for ephedrine and cryptolepine, respectively. The calibration curves were linear in a concentration range of 10–250 µg/mL for both the alkaloids with correlation coefficient values >0.99. The limits of detection and quantification for ephedrine and cryptolepine were 5 and 10 µg/mL and 2.5 and 5 µg/mL, respectively. Relative standard deviation values for intra‐day and inter‐day precision were 1.22 and 1.04% for ephedrine and 1.71 and 2.06% for cryptolepine, respectively. Analytical recovery ranged from 92.46 to 103.95%. The developed HPLC method was applied to identify and quantify ephedrine and cryptolepine in different extracts of Sida species. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

18.
A rapid and simple reverse‐phase high‐performance liquid chromatography (RP‐HPLC) was developed and validated for the quantification of kirenol in rat plasma after oral administration. Kirenol and darutoside (internal standard, IS) were extracted from rat plasma using Cleanert™ C18 solid‐phase extraction (SPE) cartridge. Analysis of the extraction was performed on a Thermo ODS‐2 Hypersil C18 reversed‐phase column with a gradient eluent composed of acetonitrile and 0.1% phosphoric acid. The flow rate was 1.0 mL/min and the detection wavelength was set at 215 nm. The calibration curve was linear over the range of 9.756–133.333 µg/mL (r2 = 0.9991) in rat plasma. The lower limits of detection and quantification were 2.857 and 9.756 µg/mL, respectively. The intra‐ and inter‐day precisions (relative standard deviation, RSD) were between 2.24 and 4.46%, with accuracies ranging from 91.80 to 102.74%. The extraction recovery ranged from 98.16 to 107.62% with RSD less than 4.81%. Stability studies showed that kirenol was stable in preparation and analytical process. The present method was successfully applied to the pharmacokinetic study of kirenol in male Sprague–Dawley rats after oral administration at a dose of 50 mg/kg. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

19.
Little is known about melamine (MEL) analysis in children's urine. In this study, an isotopic ultra‐performance liquid chromatography/tandem mass spectrometry (UPLC/MS/MS) method was developed and systematically validated for the analysis of MEL in urine. The method is easily performed and comprises acidification, solid‐phase extraction (SPE) and UPLC/MS/MS analysis. 13C3N3(15NH2)3 was used as the internal standard (IS) for calibration. Transition ions m/z 127 > 85 of MEL and m/z 133 > 89 of the IS were used for quantification and m/z 127 > 68 of MEL was used for quantitative confirmation. Recovery and precision were assessed to guarantee the applicability of the method. The limit of quantification (LOQ) was 0.01 µg/mL while the calculated method detection limit was 0.006 µg/mL. The mean recoveries ranged from 96–99%. The method was then applied to analyze urine samples from children who had potentially consumed MEL‐tainted dairy products during screening in Taiwan. Ten nephrolithiasis cases and 20 age‐ and gender‐matched controls were selected for this study. Three out of the 10 nephrolithiasis cases had elevated levels of MEL. Comparatively, twenty age‐ and gender‐matched non‐nephrolithiasis controls consuming Taiwan brand milk powder all showed MEL levels lower than the detection limit except for two children with background levels of 0.02 µg/mL. The background level in these children urine samples was established by UPLC/MS/MS analysis. Positive results of urine MEL tests might be associated with nephrolithiasis in these candidates. Measurement of urine MEL concentration can be helpful in confirming MEL‐related nephrolithiasis, but its clinical application needs further clarification. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

20.
A rapid, simple, sensitive and selective ultraperformance liquid chromatography–tandem spectrometry (UPLC‐MS/MS) method for the determination of nalbuphine and its prodrug sebacoly dinalbuphine ester (SDE) was developed and validated in human plasma. The sample pretreatment involves basification and iterative liquid–liquid extraction with ethyl‐ether–dichloromethane (7:3, v/v) solution, followed by LC separation and positive electrospray ionization (ESI) API‐3000 mass spectrometry detection. The chromatography was on a Waters Acquity UPLC BEH HILIC column (2.1 × 100 mm, 1.7 µm). The mobile phase was composed of acetonitrile and water (83:17, v/v) that contained 0.2% formic acid and 4 mm ammonium formate at a flow rate of 0.25 mL/min. Ethylmorphine and naloxine were selected as the SDE and nalbuphine internal standard (IS), respectively. The calibration curve for both was linear over the range from 0.05 to 20 ng/mL, with correlation coefficients ≥0.995. The lower limit of quantification was set at 0.05 ng/mL. The intra‐ and inter‐day precision values for nalbuphine and SDE were acceptable as per FDA guidelines. The method was applied successfully to determine nalbuphine concentration in human plasma samples obtained from four Taiwanese volunteers receiving intramuscularly administration of sebacoyl dinalbuphine ester. The method is sensitive, selective and directly applicable to human pharmacokinetic studies involving nalbuphine. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号