首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Presently, online coal ash content monitoring is performed by PGNAA (Prompt Gamma Neutron Activation Analyses) machines. Laser Detect Systems has developed an online mineral analysis system using Laser Induced Breakdown Spectroscopy (LIBS). The main advantages of the system are that it is without a radioactive source, compact (1.5 m × 0.8 m × 1.3 m), comparatively light (250 kg) and easy to install. The main disadvantage is that a LIBS system analyzes surface chemistry of the mineral exclusively and not the volume. To prove the LIBS machine analytical ability for coal ash content evaluation, a trial was arranged at Optimum Colliery (South Africa). The LIBS machine was installed in line with a PGNAA machine and laboratory data served as a referee in the final assessment for analytical accuracy. The trial was carried out over a four month period. This paper presents the successful trial results achieved for accurate (at least +/− 0.5% mean absolute error) online coal ash content monitoring.  相似文献   

2.
Size-exclusion chromatography (SEC) coupled with online laser light-scattering (LS) and refractive index (RI) detection provides an excellent approach to determine the molecular weights (Mw) of proteins by the “two-detector” approach. Mw is determined only at the maximum of a peak, using either peak heights or area ratio from the two detectors. However, proper calibration of the SEC/LS/RI system is critical to obtain high precision.Today, an essential part of any analysis is to evaluate the uncertainty associated with the method. Basically, it is possible to distinguish between factors related to signal nature, precision and those due to signal processing. Given the signal of interest is the peak height or area ratio from two detectors, the signal ratio uncertainty was calculated using the random propagation of error formula. In this case, the effect of signal correlation was evaluated to avoid the uncertainty overestimation. In the second case, the sources of uncertainty affecting analytical measurement were estimated with the information from the precision assessment. For this, two designs with two-factor fully nested were followed for each method. Finally, the contributions from various uncertainty sources related with calibration are also analysed in detail. There are in fact only three main sources of measurement uncertainty: intermediate precision, calibration and repeatability. Of these, method precision is always the greatest, regardless of approach.For all proteins and peptides studied, the Mw calculated using both methods are close to the theoretical results, independently of the design, but the contributions of individual terms to combined uncertainty depend on both the design and method used. For example, the combined uncertainty varied between 223 and 813.2 Da for carbonic anhydrase, although higher values were found for human insulin and ovalbumin dimer. Other considerations that can have a significant impact on the results are discussed.The reproducibility of the two methods versus that based on ASTRA software used as reference method was performed using the concordance correlation coefficient. The methods’ reproducibility depends on the permitted losses in precision and accuracy.  相似文献   

3.
The potential of carbon nanotubes for the solid phase extraction of parabens in cosmetic products and the detection using a corona-charged aerosol detector (C-CAD) is presented in this work. The analytical procedure is based on a conventional solid phase extraction step for which 20 mg of multi-walled carbon nanotubes were packed in a 3-mL commercial SPE cartridge. Methylparaben, ethylparaben, propylparaben and butylparaben were thus isolated and preconcentrated from the pre-treated samples and subsequently separated on a RP-C18 column using acetonitrile:water, 50:50 (v/v) as mobile phase. The analytical signals for the individual parabens were obtained using C-CAD. The experimental variables affecting the extraction procedure and the instrumental detection have been deeply studied. Limits of detection were in the range of 0.5–2.1 mg L−1, while the linear range was extended up to 400 mg L−1. The average precision of the method varied between 3.3–3.8% (repeatability) and 4.3–7.6% (reproducibility). Finally, the optimized procedure was applied to the determination of the target preservatives in a variety of cosmetic products with satisfactory results.  相似文献   

4.
Laser-induced breakdown spectroscopy is a powerful analytical method, but LIBS is subject to a matrix effect which can limit its ability to produce quantitative results in complex materials such as geologic samples. Various methods of sample preparation, calibration, and data processing have been attempted to compensate for the matrix effect and improve LIBS precision. This study focuses on sample preparation by comparing fused glass as a preparation for powdered material to the more commonly used method of pressing powder into pellets for LIBS analysis of major elements in complex geologic materials. Pelletizing powdered material is a common and convenient method for preparing samples but problems with the physical matrix brought on by inconsistencies in the homogeneity, density, and laser absorption, coupled with the chemical matrix problem lead to spectral peak responses that are not always consistent with the absolute concentration of representative elements. Twenty-two mineral and rock samples were analyzed for eight major oxide elements. Samples were prepared under both glass and pellet methods and compared for internal precision and overall accuracy. Fused glass provided a more consistent physical matrix and yielded more reliable peak responses in the LIBS analysis than did the pressed pellet preparation. Statistical comparisons demonstrated that the glass samples expressed stronger separability between different mineral species based on the eight elements than for the pressed pellets and showed better spot-to-spot repeatability. Regression models showed substantially better correlations and predictive ability among the elements for the glass preparation than did those for the pressed pellets.  相似文献   

5.
Golcu A  Dogan B  Ozkan SA 《Talanta》2005,67(4):703-712
The voltammetric behavior of cefixime was studied using cyclic, linear sweep, differential pulse and square wave voltammetric techniques. The oxidation of cefixime was irreversible and exhibited diffusion controlled process depending on pH. The oxidation mechanism was proposed and discussed. Different parameters were tested to optimize the conditions for the determination of cefixime. The dependence of current intensities and potentials on pH, concentration, scan rate, nature of the buffer was investigated. According to the linear relationship between the peak current and the concentration, differential pulse (DPV) and square wave (SWV) voltammetric methods for cefixime assay in pharmaceutical dosage forms and biological fluids were developed. For the determination of cefixime were proposed in acetate buffer at pH 4.5, which allows quantitation over the 6 × 10−6-2 × 10−4 M range in supporting electrolyte and spiked serum sample; 8 × 10−6-2 × 10−4 M range in urine sample; 6 × 10−6-1 × 10−4 M range in breast milk samples for both techniques. The repeatability, reproducibility, precision and accuracy of the methods in all media were investigated. No electroactive interferences from the excipients and endogenous substances were found in the pharmaceutical dosage forms and in the biological samples, respectively.  相似文献   

6.
The present study addresses the electrochemical behavior and the analytical applications of six 2-nitrophenylbenzimidazole derivatives with activity against Trypanosoma cruzi. When studied in a wide range of pH, by differential pulse polarography, tast polarography and cyclic voltammetry, these compounds exhibited two irreversible cathodic responses. With analytical purposes, the differential pulse polarography mode was selected, which exhibited adequate analytical parameters of repeatability, reproducibility and selectivity. The percentage of recovery was in all cases over 99%, and the detection and quantitation limits were at the level of 1 × 10−7 mol L−1 and 1 × 10−6 mol L−1, respectively. In addition, the differential pulse polarography method was successfully applied to study the hydrolytic degradation kinetic of one of the tested compounds. Activation energy, kinetic rate constants at different temperatures and half-life values of such application are reported.  相似文献   

7.
The enantiomeric fractions present in soil samples may provide information useful in distinguishing recent inputs of DDT from past DDT pollution. In this study, a chromatographic procedure for the determination of the enantiomeric fractions of o,p′-DDT based on heart-cutting multidimensional gas chromatography was developed. The optimization carried out achieved low ratios of DDT degradation (<15%) in the chromatographic system. High selectivity and sensitivity in the detection of the target compounds, with a limit of detection as low as 2.1 pg μL−1, was reached. In addition, high degrees of repeatability (RSD < 2.0%) and reproducibility (RSD < 3.2%) were obtained for the enantiomeric fractions measured in analytical standards and soil samples.  相似文献   

8.
The ‘characteristic function’ is a two-parameter function relating precision or uncertainty in analytical results to the concentration of the analyte. In previous papers, in this series, it has been shown to provide a good model of precision measured: (a) under reproducibility conditions and (b) under ‘instrumental’ conditions. The present study shows that it is also a valuable model for precision estimated under repeatability conditions. The study data were large sets of duplicated results obtained for the purposes of quality control on typical test materials in routine analysis. As the analytes exhibited concentration ranges encompassing between one and three orders of magnitude, there was ample scope to demonstrate goodness of fit to the function under different circumstances.  相似文献   

9.
A method for separation and quantitative determination of the iodosulfuron-methyl-sodium in water samples by high-performance liquid chromatography (HPLC) was developed and in-house validated in order to demonstrate its performance for monitoring of heterogeneous photocatalytic elimination of the herbicide iodosulfuron-methyl-sodium from water. Surface and ground water samples were used to demonstrate its selectivity, detection and quantification limits, linearity, trueness and precision. In addition, stability of iodosulfuron-methyl-sodium was studied in function of temperature and time. Method accuracy was quantified through measurement uncertainty estimate based on method validation data. The paper gives practical and easy to follow guidance on how uncertainty estimates can be obtained from method validation experiments. It shows that, if properly planned and executed, key precision and trueness studies undertaken for validation purposes can also provide much of the data needed to produce an estimate of measurement uncertainty. Our analytical protocol allowed us to quantify iodosulfuron-methyl-sodium in ground water and surface water in concentration level between 2.50–50.0 μmol L−1 with satisfactory recoveries (99–104%) and repeatability lower or equal than 0.3% for all the matrices. We also estimated within-laboratory reproducibility over 3-month period, which was 0.7%. We proved that the method was selective for determination of iodosulfuron-methyl-sodium in the relevant matrices. Measurement uncertainty of results was evaluated to be 4.0% with 95% confidence level. After validation and measurement uncertainty evaluation steps, results obtained showed that the method can be applied to efficiently monitor heterogenous photocatalytic degradation of the herbicide iodosulfuron-methyl-sodium.  相似文献   

10.
The automated method developed for the determination of carotenoids uses 200 μL of serum, which was mixed with 400 μL of tetrahydrofuran, vortexed for 1 min, settled for 10 min, centrifuged for 6 min and the supernatant injected into an automatic solid-phase extraction (SPE) system for cleanup-preconcentration. A 10% water-acetonitrile mobile phase at 1.5 mL min−1 eluted the retained compounds and transferred them on-line to a reversed-phase analytical column for individual separation of the target analytes. Visible detection was performed at 450 and 460 nm. The detection limits for the target analytes were between 3 and 30 ng mL−1; the precision (expressed as relative standard deviation) ranged between 2.83 and 5.06% for repeatability and between 3.80 and 7.40% for within laboratory reproducibility. The total analysis time was 18 min. The proposed method is reliable, robust, and has an excellent potential for high-throughput use in both clinical and research laboratories.  相似文献   

11.
This work describes the electroanalytical determination of pendimethalin herbicide levels in natural waters, river sediment and baby food samples, based on the electro-reduction of herbicide on the hanging mercury drop electrode using square wave voltammetry (SWV). A number of experimental and voltammetric conditions were evaluated and the best responses were achieved in Britton-Robinson buffer solutions at pH 8.0, using a frequency of 500 s− 1, a scan increment of 10 mV and a square wave amplitude of 50 mV. Under these conditions, the pendimethalin is reduced in an irreversible process, with two reduction peaks at − 0.60 V and − 0.71 V, using a Ag/AgCl reference system. Analytical curves were constructed and the detection limit values were calculated to be 7.79 μg L− 1 and 4.88 μg L− 1, for peak 1 and peak 2, respectively. The precision and accuracy were determinate as a function of experimental repeatability and reproducibility, which showed standard relative deviation values that were lower than 2% for both voltammetric peaks. The applicability of the proposed methodology was evaluated in natural water, river sediments and baby food samples. The calculated recovery efficiencies demonstrate that the proposed methodology is suitable for determining any contamination by pendimethalin in these samples. Additionally, adsorption isotherms were used to evaluate information about the behavior of pendimethalin in river sediment samples.  相似文献   

12.
A voltammetric method is proposed for the simultaneous determination of tryptophan, cysteine, and tyrosine using multivariate calibration techniques. Various electrodes and voltammetric techniques were explored to ascertain the optimum measurement strategy. Among them, differential pulse voltammetry (DPV) with a Pt electrode was selected as analytical technique since it provided a suitable compromise between sensitivity and reproducibility while allowing the oxidation peaks of the three compounds to be reasonably discriminated. The sensitivity of DPV with Pt electrode for Trp standards was 8.4×10−2 A l mol−1, the repeatability 3.7% and the detection limit below 10−7 M. The lack of full selectivity of the voltammetric data was overcome using multivariate calibration methods on the basis of the differences in the voltammetric waves of each compound. The accuracy of predictions was evaluated preliminarily from the analysis of three-component synthetic mixtures. Subsequently, this method was applied to the analysis of oxidizable amino acids in feed samples. Results obtained were in good concordance with those given by the standard method using an amino acid analyzer.  相似文献   

13.
Today it is common to find samples with various additives from several families. This is the case of sweeteners, preservatives and antioxidants. We have selected a set of additives broadly used in foods and cosmetics with an ample variety of polarities, namely: aspartame (AS), acesulfame (AK)/saccharin (SA), metylparaben (MP), ethylparaben (EP), propylparaben (PP), butylparaben (BP), propylgallate (PG) and butylhydroxyanysole (BA). The monolithic column used as separative system is a 5 mm commercial precolumn of silica C18 coupled to a flow injection manifold working with a peristaltic pump. The mixture was separated in only 400 s with resolution factors greater than 1.1 in all cases. To achieve the separation in the FIA system we used two carriers: first, a mixture of ACN/water buffered with 10 mM pH 6.0 phosphate buffer and second, a methanol:water mixture to improve the carrier strength and speed up the more apolar analytes at 3.5 mL min−1. Detection is accomplished by means of a diode array spectrometer at the respective wavelength of each compound. The comparison of the analytical parameters obtained for this procedure with a standard HPLC method validates our new method, obtaining a method that is quick, with high repeatability and reproducibility and with good resolution between analytes. We have successfully applied the method to real food and cosmetics samples.  相似文献   

14.
An efficient direct method for measuring c9,t11- and t10,c12-conjugated linoleic acid (CLA) isomer content in human and rat milk was developed and validated using an RTX-2330 capillary column (40 m × 0.18 mm × 0.1 μm). In comparison with the commonly used 100 m × 0.25 mm × 0.20 μm columns, this new type of fast column allowed the separation of FAMEs with the same resolution but in much less time. An additional advantage for biological samples was that only a small volume of sample was needed. Two different procedures were tested in order to select the best methylation of CLA isomers, and the alkali plus acid-catalyzed procedure was selected. The precision results showed relative standard deviations (R.S.D.) of repeatability and reproducibility ranging between 0.10 and 8.71%. The application of this method to human and rat milk samples showed that it was a rapid, simple and reliable method for the analysis of biological samples.  相似文献   

15.
Laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS), micro X-ray fluorescence spectroscopy (μXRF), and laser induced breakdown spectroscopy (LIBS) are compared in terms of discrimination power for a glass sample set consisting of 41 fragments. Excellent discrimination results (> 99% discrimination) were obtained for each of the methods. In addition, all three analytical methods produced very similar discrimination results in terms of the number of pairs found to be indistinguishable. The small number of indistinguishable pairs that were identified all originated from the same vehicle. The results also show a strong correlation between the data generated from the use of µXRF and LA-ICP-MS, when comparing µXRF strontium intensities to LA-ICP-MS strontium concentrations. A 266 nm laser was utilized for all LIBS analyses, which provided excellent precision (< 10% RSD for all elements and < 10% RSD for all ratios, N = 5). The paper also presents a thorough data analysis review for forensic glass examinations by LIBS and suggests several element ratios that provide accurate discrimination results related to the LIBS system used for this study. Different combinations of 10 ratios were used for discrimination, all of which assisted with eliminating Type I errors (false exclusions) and reducing Type II errors (false inclusions). The results demonstrate that the LIBS experimental setup described, when combined with a comprehensive data analysis protocol, provides comparable discrimination when compared to LA-ICP-MS and μXRF for the application of forensic glass examinations. Given the many advantages that LIBS offers, most notably reduced complexity and reduced cost of the instrumentation, LIBS is a viable alternative to LA-ICP-MS and μXRF for use in the forensic laboratory.  相似文献   

16.
A confirmatory method for the simultaneous determination of nandrolone (α and β) and trenbolone (α and β) in urine samples by liquid chromatography electrospray mass spectrometry (LC–MS-MS) was developed. After an enzymatic deconjugation, the urine was subjected to a one-step cleanup on a commercially available immunoaffinity chromatography cartridge. The analytes were detected by liquid chromatography–positive ion electrospray tandem mass spectrometry using deuterium labelled internal standards. The analytical procedure was applicable to bovine and swine urine samples. The procedure was validated as a quantitative confirmatory method according to the Commission Decision 2002/657/EC criteria. The results obtained showed that the method was suitable for statutory residues testing regarding the following performance characteristics: instrumental linearity, specificity, precision (repeatability and intra-laboratory reproducibility), recovery, decision limit (CCα), detection capability (CCβ) and ruggedness. The decision limits (CCα) obtained, were between 0.54 and 0.60 μg L−1; the recovery was above 64% for all the analytes. Repeatability was between 1.6% and 5.7% and within-laboratory reproducibility between 1.6% and 6.0% for all the steroids.  相似文献   

17.
A multiresidue HPLC method for identification and quantification of the synthetic acaricides fluvalinate, coumaphos, bromopropylate and its metabolite 4,4′-dibromobenzophenone in beeswax has been developed. Different techniques were tested and modified. The method consists of a sample preparation with isooctane followed by solid phase extraction using Florisil columns. Determination of the synthetic acaricides is achieved by HPLC with a photodiode array detector. Analytical performance of the proposed method, including sensitivity, accuracy and precision was satisfactory. The LOD for the analytes varied between 0.1 and 0.2 μg g−1 wax and the recoveries between 70 and 110%. Relative standard deviation of the repeatability of the method is <15% and reproducibility is <31%.  相似文献   

18.
The presence of β-boldenone II phase metabolites and prednisolone in urine samples, owing to endogenous or natural origin or illicit treatment, is under debate within the European Union. The detection of β-boldenone conjugates, α-boldenone conjugates at concentrations higher than 2 ng mL−1 and prednisolone above the cut-off level of 5 ng mL−1 in urine have been, until now, critical in deciding if illegal drug use has occurred. The use of urine sometimes is not entirely satisfactory, especially when the drug is administrated at low doses or when its metabolic conversion is very fast. This subsequently would hamper its detection in urine. The introduction of a new, advantageous matrix where the illicit treatment can be investigated would be highly appreciated. In this study, we have developed and validated a simple and unique immunoaffinity clean-up procedure, which was applied to bovine bile samples, followed by two different analytical liquid chromatography-electrospray-tandem mass spectrometry methods. The first method tests androstadienedione, α- and β-boldenone sulphate, glucuronate and related free forms, while the other method assays prednisolone, prednisone, dexamethasone, cortisone, and cortisol. The methods were validated according to European Commission Decision 2002/657/EC. The evaluated parameters were linearity, specificity, precision (repeatability and intra-laboratory reproducibility), recovery, decision limit and detection capability. The decision limits (CCα) were between 0.38 and 0.45 ng mL−1 for anabolic steroids, and 0.13 and 0.15 ng mL−1 as far as corticosteroids were concerned. Intra- and inter-day repeatability was below 15.8 and 19.9% for all analytes, respectively. The methods were applied to the analysis of some bile samples collected from untreated young bulls in order to investigate the presence of the studied steroids in this matrix.  相似文献   

19.
Arnab Sarkar 《Talanta》2009,78(3):800-1664
Laser-induced breakdown spectroscopy (LIBS) has been developed for determining the percentage of uranium in thorium-uranium mixed oxide fuel samples required as a part of the chemical quality assurance of fuel materials. The experimental parameters were optimized using mixed oxide pellets prepared from 1:1 (w/w) mixture of thorium-uranium mixed oxide standards and using boric acid as a binder. Calibration curves were established using U(II) 263.553 nm, U(II) 367.007 nm, U(II) 447.233 nm and U(II) 454.363 nm emission lines. The uranium amount determined in two synthetic mixed oxide samples using calibration curves agreed well with that of the expected values. Except for U(II) 263.553 nm, all the other emission lines exhibited a saturation effect due to self-absorption when U amount exceeded 20 wt.% in the Th-U mixture. The present method will be useful for fast and routine determination of uranium in mixed oxide samples of Th and U, without the need for dissolution, which is difficult and time consuming due to the refractory nature of ThO2. The methodology developed is encouraging since a very good analytical agreement was obtained considering the limited resolution of the spectrometer employed in the work.  相似文献   

20.
To support effective process development there is a requirement for rapid analytical methods that can identify and quantitate adenoviral particles throughout the manufacturing process, from cellular lysate through to purified adenovirus. An anion-exchange high-performance liquid chromatography method for the analysis of adenovirus type 5 (Ad5) particles has been developed using a novel quaternary amine monolithic column (Bio-Monolith QA, Agilent). The developed method separates intact Ad5 from contaminating proteins and DNA, thus allowing analysis of non-purified samples during process development. Regeneration conditions were incorporated to extend the functional life of the column. Once developed, the method was qualified according to performance criteria of repeatability, intermediate precision and linearity. The linear working range of analysis was established between 7.5 × 108 to at least 2.4 × 1010 viral particles (3 × 1010 to 9.6 × 1011 viral particles/mL), with a correlation coefficient of 0.9992. Relative standard deviations (RSDs) for intra- and inter-day repeatability and precision for retention time and peak area were less than 1 and 2.5%, respectively.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号