生物样本中的蛋白质复杂程度很高,尚无一种分析方法能够全面分析复杂生物样本中的所有蛋白质。实验证明:重复的质谱分析能增加蛋白质的鉴定数量,但鉴定到的蛋白质冗余度很高,高丰度肽段被反复检出。为了降低鉴定冗余度,提高鉴定效率,对线性离子阱-傅立叶变换离子回旋共振质谱仪的串联质谱采集方法进行了研究,建立了基于母离子排除的串联质谱采集方法。此方法能极大降低二级质谱采集的冗余度,提高蛋白质的鉴定效率。  相似文献   

2.
Combining source collision-induced dissociation (CID) and tandem mass spectral acquisition in a pseudo-MS(3) experiment using a linear ion trap results in a highly selective and sensitive approach to identifying glycopeptide elution from a protein digest. The increased sensitivity is partially attributed to the nonselective nature of source CID, which allows simultaneous activation of all charge states and coeluting glycoforms generating greater ion abundance for the mass-to-charge (m/z) 204 and/or 366 oxonium ions. Unlike source CID alone, a pseudo-MS(3) approach adds selectivity while improving sensitivity by eliminating chemical noise during the tandem mass spectral acquisition of the oxonium ions in the linear ion trap. Performing the experiments in the hybrid linear ion trap/Fourier transform-ion cyclotron resonance (FT-ICR) enables subsequent high-resolution/high-mass accuracy full-scan mass spectra (MS) and parallel acquisition of MS/MS in the linear ion trap to be completed in 2 s directly following the pseudo-MS(3) scan to collate identification and characterization of glycopeptides in one experimental scan cycle. Analysis of bovine fetuin digest using the combined pseudo-MS(3), high-resolution MS, and data-dependent MS/MS events resulted in identification of four N-linked and two O-linked glycopeptides without enzymatic cleavage of the sugar moiety or release of the sialic acids before analysis. In addition, over 95% of the total protein sequence was identified in one analytical run.  相似文献   

3.
A rapid means of identifying many components in an enriched mixture of proteins is enzymatic digestion of the entire protein fraction. This complex peptide mixture is then subjected to reversed-phase high performance liquid chromatography (HPLC) coupled on-line with a mass spectrometer capable of data-dependent ion selection for fragmentation (LC-tandem mass spectrometry; MS/MS). Thus, as many peptides as possible in the sample are fragmented to produce MS/MS spectra, which can then be searched against sequence databases. Ideally, one peptide from each protein in the mixture would be fragmented and identified. To this end, we employed an affinity selection method to capture cysteinyl peptides and thereby simplify the mixture. Both the captured cysteinyl and the noncysteinyl peptides are analyzed by LC-MS/MS, to increase the number of proteins identified. The method was tested on a limited set of standard proteins and applied to the analysis of a protein fraction obtained from isolated mitochondria treated with atractyloside. To further increase the number of different precursor ions selected for fragmentation, dynamic exclusion and ion selection from multiple narrow mass ranges of consecutive runs were employed.  相似文献   

4.
Although data-dependent LC-MS-MS with database searching has become au courant for identifying proteins, the technique is constrained by duty-cycle inefficiency and the inability of most tandem mass analyzers to accurately measure peptide product ion masses. In this work, a novel approach is presented for simultaneous peptide fragmentation and accurate mass measurement using in-source collision-induced dissociation (CID) on electrospray ionization (ESI)-time-of-flight (TOF) MS. By employing internal mass reference compounds, mass measurement accuracy within +/-5 ppm for tryptic peptide precursors and +/-10 ppm for most sequence-specific product ions was consistently achieved. Analysis of a complex solution containing several digested protein standards did not adversely affect instrument performance.  相似文献   

5.
Desorption electrospray ionization mass spectrometry (DESI-MS) was demonstrated as a method to detect and identify peptides from two-dimensional separations of cytochrome c and myoglobin tryptic digests on ProteoChrom HPTLC Cellulose sheets. Data-dependent tandem mass spectra were acquired during lane scans across the TLC plates. Peptides and the corresponding proteins were identified using a protein database search software. Two-dimensional distributions of identified peptides were mapped for each separated protein digest. Sequence coverages for cytochrome c and myoglobin were 81 and 74%, respectively. These compared well with those determined using the more standard HPLC/ESI-MS/MS approach (89 and 84%, respectively). Preliminary results show that use of more sensitive instrumentation has the potential for improved detection of peptides with low R(f) values and improvement in sequence coverage. However, less multiple charging and more sodiation were seen in HPTLC/DESI-MS spectra relative to HPLC/ESI-MS spectra, which can affect peptide identification by MS/MS. Methods to increase multiple charging and reduce the extent of sodiation are currently under investigation.  相似文献   

6.
Capillary separations interfaced to tandem mass spectrometry provide a very powerful tool for the characterization of biological macromolecules such as proteins and peptides. The development of real time data-dependent data acquisition has further enhanced the capability of this method. However, the application of this technique to fast capillary separations has been limited by the relatively slow spectral acquisition speed available on scanning mass spectrometers. In this work, an ion trap storage/reflectron time-of-flight mass spectrometer (IT/reTOF-MS) has been used as an on-line tandem mass detector for capillary high-performance liquid chromatography (HPLC) and capillary electrophoresis (CE) separations of peptide mixtures including a protein digest. By taking advantage of the nonscanning property of the time-of-flight mass spectrometer, a fast spectral acquisition rate has been achieved. This fast spectral acquisition rate, combined with a new protocol that speeds up tickle voltage optimization, has provided MS/MS spectra for multiple components in a hemoglobin digest during one liquid chromatography/mass spectrometry/mass spectrometry (LC/MS/MS) run. Further, the IT/reTOF-MS has the speed to provide MS/MS spectra for multiple components in a CE separation of a synthetic peptide mixture within one CE/MS/MS run.  相似文献   

7.
An automated top-down approach including data-dependent MS(3) experiment for protein identification/characterization is described. A mixture of wild-type yeast proteins has been separated on-line using reverse-phase liquid chromatography and introduced into a hybrid linear ion trap (LTQ) Fourier transform ion cylclotron resonance (FTICR) mass spectrometer, where the most abundant molecular ions were automatically isolated and fragmented. The MS(2) spectra were interpreted by an automated algorithm and the resulting fragment mass values were uploaded to the ProSight PTM search engine to identify three yeast proteins, two of which were found to be modified. Subsequent MS(3) analyses pinpointed the location of these modifications. In addition, data-dependent MS(3) experiments were performed on standard proteins and wild-type yeast proteins using the stand alone linear trap mass spectrometer. Initially, the most abundant molecular ions underwent collisionally activated dissociation, followed by data-dependent dissociation of only those MS(2) fragment ions for which a charge state could be automatically determined. The resulting spectra were processed to identify amino acid sequence tags in a robust fashion. New hybrid search modes utilized the MS(3) sequence tag and the absolute mass values of the MS(2) fragment ions to collectively provide unambiguous identification of the standard and wild-type yeast proteins from custom databases harboring a large number of post-translational modifications populated in a combinatorial fashion.  相似文献   

8.
Keratinocytes are potential targets of lipid peroxidation products (alpha,beta-unsaturated aldehydes) generated in the skin following UV exposure, among which the most abundant and toxic product is 4-hydroxy-trans-2,3-nonenal (HNE). The aim of this study was to investigate the ability of keratinocytes (NCTC2544 cell lines) to detoxify HNE, through characterization of metabolites, until now never demonstrated, using a combined analytical approach (liquid chromatography (LC) and liquid chromatography/mass spectrometry (LC/MS)). Incubation of cells with HNE (up to 200 micro M) was performed in order to evaluate the ability of the cells to detoxify this toxic aldehyde, and indicated that the cell viability was maintained under these conditions. LC analysis of the extracellular media from keratinocytes incubated with 100 micro M HNE shows a time-dependent decrease of HNE, disappearance from the medium within 2 h and concomitant formation of two unconjugated (phase I) metabolites, 4-hydroxy-2-nonenoic acid (HNA) and 1,4-dihydroxy-2-nonene (DHN), which were both identified and quantified by LC and accounted for 48.8 +/- 4.6% of the HNE dose. Four additional metabolites were identified in the extracellular medium by reversed-phase LC coupled with electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) with positive and negative ion detection as Michael adducts (phase II metabolites), arising by the addition of the nucleophilic sulfur of glutathione (GSH) to the electrophilic C-3 of HNE, followed by oxidation-reduction enzymatic processes. The GSH-HNE conjugates were (a) S-(4-hydroxynonanal-3-yl)glutathione, (b) S-(1,4-dihydroxy-nonane-3-yl)glutathione, (c) S-(4-oxononanal-3-yl)glutathione and (d) S-(4-oxo-nonan-1-ol-3-yl)glutathione, and accounted for 52.3 +/- 5.8% of the HNE dose (35 nmol mg(-1) protein), as estimated indirectly by measuring the extent of cellular GSH consumption (18.7 +/- 1.8 nmol mg(-1) protein). The time course of HNE biotransformation was then determined by monitoring the formation of metabolites inside and outside the cell at different times after HNE addition (5-120 min). A time-dependent and almost linear formation inside the cell was observed for all the metabolites (plateau after 15 min of incubation), followed by a rapid decay and a concomitant increase in the extracellular medium (plateau of formation after 60 min). This confirms that HNE diffuses into the cell where is totally metabolized through phase I and phase II reactions to unreactive products, which are then exported outside the cell. This is the first demonstration that skin epidermal cells are able to detoxify the cytotoxic products of lipid peroxidation.  相似文献   

9.
Modification of proteins by 4‐hydroxy‐2‐nonenal (HNE), a reactive by‐product of ω6 polyunsaturated fatty acid oxidation, on specific amino acid residues is considered a biomarker for oxidative stress, as occurs in many metabolic, hereditary, and age‐related diseases. HNE modification of amino acids can occur either via Michael addition or by formation of Schiff‐base adducts. These modifications typically occur on cysteine (Cys), histidine (His), and/or lysine (Lys) residues, resulting in an increase of 156 Da (Michael addition) or 138 Da (Schiff‐base adducts), respectively, in the mass of the residue. Here, we employed biochemical and mass spectrometry (MS) approaches to determine the MS “signatures” of HNE‐modified amino acids, using lysozyme and BSA as model proteins. Using direct infusion of unmodified and HNE‐modified lysozyme into an electrospray quadrupole time‐of‐flight mass spectrometer, we were able to detect up to seven HNE modifications per molecule of lysozyme. Using nanoLC‐MS/MS, we found that, in addition to N‐terminal amino acids, Cys, His, and Lys residues, HNE modification of arginine (Arg), threonine (Thr), tryptophan (Trp), and histidine (His) residues can also occur. These sensitive and specific methods can be applied to the study of oxidative stress to evaluate HNE modification of proteins in complex mixtures from cells and tissues under diseased versus normal conditions.  相似文献   

10.
Identification of protein carbonylation because of covalent attachment of a lipid peroxidation end‐product was performed by combining proteolytic digestion followed by solid‐phase hydrazide enrichment and liquid chromatography (LC)–electrospray ionization (ESI) tandem mass spectrometry (MS/MS) using both collision‐induced dissociation (CID) and electron capture dissociation (ECD). To evaluate this approach, we selected apomyoglobin and 4‐hydroxy‐2‐nonenal (4‐HNE) as a model protein and a representative end‐product of lipid peroxidation, respectively. Although the characteristic elimination of 4‐HNE (156 Da) in CID was found to serve as a signature tag for the modified peptides, generation of nearly complete fragment ion series because of efficient peptide backbone cleavage (in most cases over 75%) and the capability to retain the labile 4‐HNE moiety of the tryptic peptides significantly aided the elucidation of primary structural information and assignment of exact carbonylation sites in the protein, when ECD was employed. We have concluded that solid‐phase enrichment with both CID‐ and ECD‐MS/MS are advantageous during an in‐depth interrogation and unequivocal localization of 4‐HNE‐induced carbonylation of apomyoglobin that occurs via Michael addition to its histidine residues. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

11.
Chemical cross-linking combined with mass spectrometry (MS) is an analytical tool used to elucidate the topologies of proteins and protein complexes. However, identification of the low abundance cross-linked peptides and modification sites amongst a large quantity of proteolytic fragments remains challenging. In this work, we present a strategy to identify cross-linked peptides by negative ion MS for the first time. This approach is based around the facile cleavages of disulfide bonds in the negative mode, and allows identification of cross-linked products based on their characteristic fragmentations. MS(3) analysis of the cross-linked peptides allows for their sequencing and identification, with residue specific location of cross-linking sites. We demonstrate the applicability of the commercially available cystine based cross-linking reagent dithiobis(succinimidyl) propionate (DSP) and identify cross-linked peptides from ubiquitin. In each instance, the characteristic fragmentation behavior of the cross-linked species is described. The data presented here indicate that this negative ion approach may be a useful tool to characterize the structures of proteins and protein complexes, and provides the basis for the development of high throughput negative ion MS chemical cross-linking strategies.  相似文献   

12.
We developed a liquid chromatography electrospray ionisation multi-stage mass spectrometry (LC-ESI-MS/MS) approach based on precursor-ion scanning and evaluated it to characterize the covalent modifications of Cys34 human serum albumin (HSA) caused by oxidative stress and reactive carbonyl species (RCS) adduction. HSA was isolated and digested enzymatically to generate a suitable-length peptide (LQQCPF) containing the modified tag residue. The resulting LQQCPF peptides were identified by LC-ESI-MS/MS in precursor-ion scan mode and further characterized in product-ion scan mode. The product ions for precursor-ion scanning were selected by studying the MS/MS fragmentation of a series of LQQCPF derivatives containing Cys34 modified with different alpha,beta-unsaturated aldehydes and di and ketoaldehydes. We used a Boolean logic to enhance the specificity of the method: this reconstitutes a virtual current trace (vCT) showing the peaks in the three precursor-ion scans, marked by the same parent ion. The method was first evaluated to identify and characterize the Cys34 covalent adducts of HSA incubated with 4-hydroxy-hexenal, 4-hydroxy-trans-2-nonenal (HNE) and acrolein (ACR). Then we studied the Cys34 modification of human plasma incubated with mildly oxidized low-density lipoproteins (LDL), and the method easily identified the LQQCPF adducts with HNE and ACR. In other experiments, plasma was oxidized by 2,2'-azobis(2-amidinopropane) HCl (AAPH) or by Fe2+/H2O2. In both conditions, the sulfinic derivative of LQQCPF was identified and characterized, indicating that the method is suitable not only for studying RCS-modified albumin, but also to check the oxidative state of Cys34 as a marker of oxidative damage.  相似文献   

13.
Pelzing M  Neusüss C 《Electrophoresis》2005,26(14):2717-2728
Liquid chromatography (LC) nanoelectrospray-tandem mass spectrometry (MS/MS) is a key technology for the study of proteomics, with the main benefit to the characterization of sensitive peptides from complex mixtures. Capillary electrophoresis coupled to mass spectrometry (MS) has been taken into consideration sporadically due to the highly efficient separation and ability to handle low sample amount, yet classified as being less sensitive with respect to analyte concentration. The limitation in capillary zone electrophoresis (CZE) injection volumes can be overcome by on-line solid-phase extraction (SPE). Such an on-line SPE-CZE system was explored in combination with an ion trap (IT) mass spectrometer. Thus, it was possible to inject more than 100 microL sample solution on to the CZE capillary. Concentration limits of detection as low as 100 amol/microL were demonstrated for a peptide standard. This SPE-CZE-microelectrospray ionization (ESI)-MS/MS setup was compared directly to nanoLC/nanoESI using the same sample of a tryptic digest of bovine serum albumin (BSA) as a reference standard. Measurements were made on one IT mass spectrometer with identical acquisition parameters. Both chromatography systems enabled the separation and detection of low levels of peptides from a mixture of moderate complexity, with most peptides identified using both techniques; however, specific differences were obvious. The nanoLC-MS is about five times more sensitive than the CZE-MS, yet the difference was less pronounced than expected. The CZE-MS technique showed reduced loss of peptides, especially for larger peptides (missed cleavages) and is about four times faster than the nanoLC-MS approach.  相似文献   

14.
Bacterial adenosine diphosphate-ribosyltransferases (ADPRTs) are toxins that play a significant role in pathogenicity by inactivating host proteins through covalent addition of ADP-ribose. In this study we used ADP-ribosylated Kemptide (LRRASLG) as a standard to examine the effectiveness of three common tandem mass spectrometry fragmentation methods for assignment of amino acid sequence and site of modification. Fragmentation mechanisms investigated include low-energy collision-induced dissociation (CID), infrared multiphoton dissociation (IRMPD), and electron-capture dissociation (ECD); all were performed on a hybrid linear ion trap Fourier transform ion cyclotron resonance mass spectrometer. We show that ECD, but neither CID nor IRMPD, of ADP-ribosylated Kemptide produces tandem mass spectra that are interpretable with regard to amino acid sequence assignment and site of modification. Examination of CID and IRMPD tandem mass spectra of ADP-ribosylated Kemptide revealed that fragmentation was primarily focused to the ADP-ribose region, generating several potential diagnostic ions for use in discovery of ADP-ribosylated proteins. Because of the lower relative sensitivity of ECD during data-dependent acquisition to CID, we suggest a 2-fold strategy where CID and IRMPD are first used to detect ADP-ribosylated peptides, followed by sequence assignment and location of modification by ECD analysis.  相似文献   

15.
This Tutorial is an introduction to statistical design of experiments (DOE) with focus on demonstration of how DOE can be useful to the mass spectrometrist. In contrast with the commonly used one factor at a time approach, DOE methods address the issue of interaction of variables and are generally more efficient. The complex problem of optimizing data-dependent acquisition parameters in a bottom-up proteomics LC-MS/MS analysis is used as an example of the power of the technique. Using DOE, a new data-dependent method was developed that improved the quantity of confidently identified peptides from rat serum.  相似文献   

16.
We present a precursor ion independent top-down algorithm (PIITA) for use in automated assignment of protein identifications from tandem mass spectra of whole proteins. To acquire the data, we utilize data-dependent acquisition to select protein precursor ions eluting from a C4-based HPLC column for collision induced dissociation in the linear ion trap of an LTQ-Orbitrap mass spectrometer. Gas-phase fractionation is used to increase the number of acquired tandem mass spectra, all of which are recorded in the Orbitrap mass analyzer. To identify proteins, the PIITA algorithm compares deconvoluted, deisotoped, observed tandem mass spectra to all possible theoretical tandem mass spectra for each protein in a genomic sequence database without regard for measured parent ion mass. Only after a protein is identified, is any difference in measured and theoretical precursor mass used to identify and locate post-translation modifications. We demonstrate the application of PIITA to data generated via our wet-lab approach on a Salmonella typhimurium outer membrane extract and compare these results to bottom-up analysis. From these data, we identify 154 proteins by top-down analysis, 73 of which were not identified in a parallel bottom-up analysis. We also identify 201 unique isoforms of these 154 proteins at a false discovery rate (FDR) of <1%.  相似文献   

17.
When lipid membranes containing ω‐6 polyunsaturated fatty acyl chains are subjected to oxidative stress, one of the reaction products is 4‐hydroxy‐2‐nonenal (HNE)—a chemically reactive short chain alkenal that can covalently modify proteins. The ubiquitin proteasome system is involved in the clearing of proteins modified by oxidation products such as HNE, but the chemical structure, stability and function of ubiquitin may be impaired by HNE modification. To evaluate this possibility, the susceptibility of ubiquitin to modification by HNE has been characterized over a range of concentrations where ubiquitin forms non‐covalent oligomers. Results indicate that HNE modifies ubiquitin at only two of the many possible sites, and that HNE modification at these two sites alters the ubiquitin oligomerization equilibrium. These results suggest that any role ubiquitin may have in clearing proteins damaged by oxidative stress may itself be impaired by oxidative lipid degradation products. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

18.
Since protein phosphorylation is a dominant mechanism of information transfer in cells, there is a great need for methods capable of accurately elucidating sites of phosphorylation. In recent years mass spectrometry has become an increasingly viable alternative to more traditional methods of phosphorylation analysis. The present study used immobilized metal affinity chromatography (IMAC) coupled with a linear ion trap mass spectrometer to analyze phosphorylated proteins in mouse liver. A total of 26 peptide sequences defining 26 sites of phosphorylation were determined. Although this number of identified phosphoproteins is not large, the approach is still of interest because a series of conservative criteria were adopted in data analysis. We note that, although the binding of non-phosphorylated peptides to the IMAC column was apparent, the improvements in high-speed scanning and quality of MS/MS spectra provided by the linear ion trap contributed to the phosphoprotein identification. Further analysis demonstrated that MS/MS/MS analysis was necessary to exclude the false-positive matches resulting from the MS/MS experiments, especially for multiphosphorylated peptides. The use of the linear ion trap considerably enabled exploitation of nanoflow-HPLC/MS/MS, and in addition MS/MS/MS has great potential in phosphoproteome research of relatively complex samples.  相似文献   

19.
We evaluate the effect of ion-abundance threshold settings for data-dependent acquisition on a hybrid LTQ-Orbitrap mass spectrometer, analyzing features such as the total number of spectra collected, the signal to noise ratio of the full MS scans, the spectral quality of the tandem mass spectra acquired, and the number of peptides and proteins identified from a complex mixture. We find that increasing the threshold for data-dependent acquisition generally decreases the quantity but increases the quality of the spectra acquired. This is especially true when the threshold setting is set above the noise level of the full MS scan. We compare two distinct experimental configurations: one where full MS scans are acquired in the Orbitrap analyzer while tandem MS scans are acquired in the LTQ analyzer, and one where both full MS and tandem MS scans are acquired in the LTQ analyzer. We examine the number of spectra, peptides, and proteins identified under various threshold conditions, and we find that the optimal threshold setting is at or below the respective noise level of the instrument regardless of whether the full MS scan is performed in the Orbitrap or in the LTQ analyzer. When comparing the high-throughput identification performance of the two analyzers, we conclude that, used at optimal threshold levels, the LTQ and the Orbitrap identify similar numbers of peptides and proteins. The higher scan speed of the LTQ, which results in more spectra being collected, is roughly compensated by the higher mass accuracy of the Orbitrap, which results in improved database searching and peptide validation software performance.  相似文献   

20.
Glycation is a non‐enzymatic reaction of protein amino and guanidino groups with reducing sugars or dicarbonyl products of their oxidative degradation. Modification of arginine residues by dicarbonyls such as glyoxal and methylglyoxal results in formation of advanced glycation end‐products (AGEs). In mammals, these modifications impact in diabetes mellitus, uremia, atherosclerosis and ageing. However, due to the low abundance of individual AGE‐peptides in enzymatic digests, these species cannot be efficiently detected by LC‐ESI‐MS‐based data‐dependent acquisition (DDA) experiments. Here we report an analytical workflow that overcomes this limitation. We describe fragmentation patterns of synthetic AGE‐peptides and assignment of modification‐specific signals required for unambiguous structure retrieval. Most intense signals were those corresponding to unique fragment ions with m/z 152.1 and 166.1, observed in the tandem mass spectra of peptides, containing glyoxal‐ and methylglyoxal‐derived hydroimidazolone AGEs, respectively. To detect such peptides, specific and sensitive precursor ion scanning methods were established for these signals. Further, these precursor ion scans were incorporated in conventional bottom‐up proteomic approach based on data‐dependent acquisition (DDA) LC‐MS/MS experiments. The method was successfully applied for the analysis of human serum albumin (HSA) and human plasma protein tryptic digest with subsequent structure confirmation by targeted LC‐MS/MS (DDA). Altogether 44 hydroimidazolone‐ and dihydroxyimidazolidine‐derived peptides representing 42 AGE‐modified proteins were identified in plasma digests obtained from type 2 diabetes mellitus (T2DM) patients. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   