首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 312 毫秒
1.
In this study, a series of poly(divinylbenzene-alkyl methacrylate) monolithic stationary phases, which were prepared by single step in situ polymerization of divinylbenzene and various alkyl methacrylates (butyl-, octyl-, or lauryl-methacrylate), were developed as separation columns of benzophenone compounds for capillary electrochromatography (CEC). In addition to the presence of plenty of benzene moieties, the stationary phases contained long and flexible alkyl groups on the surface. With an increase in the molecular length of alkyl methacrylate, the polymeric monolith, which had higher hydrophobicity, effectively reduced the peak tailing of benzophenones, but a weaker retention was observed. The unusual phenomenon was likely due to the π–π interaction between the aromatic compound and the polymeric material. The usage of longer alkyl methacrylate as reaction monomer limited the retention of aromatic compounds on the stationary phase surface, thus the π–π interaction between them was possibly reduced. Consequently, the retention time of aromatic compounds was markedly decreased with an increase in carbon length of alkyl methacrylate that was carried on the polymeric monolith. Compared to previous reports on polystyrene-based columns in which the peak-tailing problem was reduced by decreasing the benzene moieties on the stationary phase, this study demonstrated that the undesirable retention (peak-tailing) could also be improved by the inclusion of long alkyl methacrylate to the polystyrene-based columns.  相似文献   

2.
Three end-capped para-benzoyl calixarene bonded silica gel stationary phases are prepared and characterized by elemental analysis, infrared spectroscopy, and thermal analysis. The comparison and selectivity of these phases are investigated by using PAHs, disubstituted benezene, and naphthalene positional isomers as probes. Possible separation mechanism based on the different interactions between calixarenes and analytes are discussed. The results indicate that the separation for those analytes are influenced by the supramolecular interaction including π-π interaction, π-electron transfer interactions, space steric hindrance, and hydrogen bonding interaction on the calixarene columns. Importantly, the aromatic probes with polar groups such as -OH, -NO(2), and -NH(2) could regulate the selectivity of calixarene-bonded stationary phases.  相似文献   

3.
The application of carbon nanotube or nanorod/polyacrylonitrile (PAN) composite electrospun nanofibrous stationary phase for ultrathin layer chromatography (UTLC) is described herein. Multi-walled carbon nanotubes (MWCNTs) and edge-plane carbon (EPC) nanorods were prepared and electrospun with the PAN polymer solution to form composite nanofibers for use as a UTLC stationary phase. The analysis of laser dyes demonstrated the feasibility of utilizing carbon nanoparticle-filled electrospun nanofibers as a UTLC stationary phase. The contribution of MWCNT or EPC in changing selectivity of the stationary phase was studied by comparing the chromatographic behavior among MWCNT–PAN plates, EPC–PAN plates and pure PAN plates. Carbon nanoparticles in the stationary phase were able to establish strong π–π interactions with aromatic analytes. The separation of five polycyclic aromatic hydrocarbons (PAHs) demonstrated enhanced chromatographic performance of MWCNT-filled stationary phase by displaying substantially improved resolution and separation efficiency. Band broadening of the spots for MWCNT or EPC-filled UTLC stationary phases was also investigated and compared with that for pure PAN stationary phases. A 50% improvement in band dispersion was noted using the MWCNT based composite nanofibrous UTLC plates.  相似文献   

4.
The frontal analysis method was used to measure the adsorption isotherms of phenol, 4-chlorophenol, p-cresol, 4-methoxyphenol and caffeine on a series of columns packed with home-made alkyl-phenyl bonded silica particles. These ligands consist of a phenyl ring tethered to the silica support via a carbon chain of length ranging from 0 to 4 atoms. The adsorption isotherm models that fit best to the data account for solute–solute interactions that are likely caused by π–π interactions occurring between aromatic compounds and the phenyl group of the ligand. These interactions are the dominant factor responsible for the separation of low molecular weight aromatic compounds on these phenyl-type stationary phases. The saturation capacities depend on whether the spacer of the ligands have an even or an odd number of carbon atoms, with the even alkyl chain lengths having a greater saturation capacity than the odd alkyl chain lengths. The trends in the adsorption equilibrium constant are also significantly different for the even and the odd chain length ligands.  相似文献   

5.
The retention behaviour of a series of 15 n-alkylbenzenes and pentylbenzene structural isomers and benzene were investigated using porous graphitic carbon (PGC) and octadecyl-bonded silica (ODS) stationary phases. Shorter chain n-alkylbenzenes and benzene (n = 0–6), and all the pentylbenzene isomers were more strongly retained on ODS, although the selectivity was greater with PGC. For the pentylbenzene analytes the degree of branching in the alkyl chain at the position adjacent to the aromatic ring affects retention on PGC, with higher retention in less branched molecules. Molecular modelling studies have provided new insights into the geometry of aromatic π–π stacking interactions in retention on PGC. For alkylbenzenes with high branching at the position adjacent to the ring, the preferred geometry of association with the surface is with the branched chain directed away from the surface, a geometry not seen in the other alkylbenzenes. The most energetically favoured orientation for interaction between analytes and the PGC surface was found to be cofacial for toluene and ethylbenzene, whereas for other analytes this interaction was in a face-edge orientation. The alternative geometry of association observed with both toluene and ethylbenzene may explain the enhanced retention of these two analytes on PGC compared with their longer chain analogues. Quantitative structure–retention relationships revealed the importance of compactness in analyte structure during retention on PGC, with decreased compactness (associated with longer chain length and reduced chain branching) improving retention.  相似文献   

6.
A simple approach to fabricate hybrid monolithic column within the confines of fused-silica capillaries (75 μm i.d.) was introduced. A polyhedral oligomeric silsesquioxanes (POSS) reagent containing a methacrylate group was selected as functional monomer, and copolymerized with bisphenol A dimethacrylate (BPADMA) or ethylene dimethacrylate (EDMA) in the presence of porogenic solvents via thermally initiated free radical polymerization. After optimization of the preparation conditions, two POSS-containing hybrid monoliths were successfully prepared and exhibited good permeability and stability. By comparison of the separation efficiencies of the resulting poly(POSS-co-BPADMA) and poly(POSS-co-EDMA) monoliths in capillary electrochromatography (CEC) and capillary liquid chromatography (cLC), it was indicated the former has better column efficiencies for alkylbenzenes, phenols, anilines and PAHs in CEC and cLC than the latter. Particularly, the hybrid poly(POSS-co-BPADMA) monolith is more suitable for separation of PAHs due to π–π interaction between the analytes and aromatic rings in the surface of monolithic stationary phase.  相似文献   

7.
Two open-tubular (OT) capillary electrochromatographic (CEC) columns were prepared by chemically bonding ionizable mono-(2-(methacryloyloxy)ethyl) succinate (MES) and phthalate-functionalized (MEP) ligands onto silica hydride-based phases through surface etching, silanization, and hydrosilation reactions, starting with a bare fused-silica tube. An analysis of the effect of performance of electrophoretic flow (EOF) on the changes in pH values, ionic strength, and the amount of acetonitrile modifiers helped to reveal that some silanol groups remained in the surface composite of the modified capillaries and to prove that MEP capillaries actually exerted greater EOF than MES ones. To explore the potential utilization of these two columns in various fields, three categories of samples, which spanned a wide range of polarities, were prepared and analyzed through many systematic trials of optimizing CEC conditions. For the separation of a mixture of nucleosides and thymine, guanine and adenine with purine uncleobases, which exhibit greater aromaticity than pyrimidine nucleobases, performed a higher retention in the MEP capillary through a π–π interaction than in the MES capillary. While four steroids were used as test samples, their migration order revealed that the MES stationary phase is hydrophilic in comparison with the MEP. An addition of methanol modifier (30%, v/v) into 10 mM borate buffer (pH 9.55 for MEP; pH 10.0 for MES) was necessary to accomplish a baseline separation of nine flavonoids in the MEP and MES capillaries. Studies on the elution order of these solutes revealed the presence of chromatographic activity in addition to electrophoretic migration. Especially in the MEP capillary, hydrophobic characteristics and π–π interactions with aromatic solutes were found and further improved to resolve an enantiomeric pair, catechin and epicatechin. Overall, the hydride-based stationary phases with ionizable ligands were successfully applied to the OT-CEC separations, and these results confidently propose an ideal route to the synthesis of a novel OT-CEC column.  相似文献   

8.
Enantiomeric separation of two aromatic α-substituted alanine esters was achieved on two commercially available polysaccharide-based chiral stationary phases (CSPs): amylose tris(3,5-dimethylphenylcarbamate) (ADMPC) and cellulose tris(3,5-dimethylphenylcarbamate) (CDMPC). The interactions between enantiomeric analytes and the CSPs were investigated using chromatographic methods and vibration circular dichroism (VCD). The two analytes differ on the aromatic portion of the molecules where one analyte has a π-acceptor aromatic ring (1) while the other has a π-donor aromatic ring (2). When an ADMPC CSP was employed, an increase in the polarity of the mobile phase leads to a reversal of the elution order for the two enantiomers of 1. The elution order of compound 2 was not affected by the polarity of the mobile phase. In order to gain an understanding of these phenomena, the enantiomeric separation of 1 and 2 was also performed on the CDMPC CSP. Interestingly, no reversal of elution order was observed upon the chromatographic separation of both pairs of enantiomers of compounds 1 and 2 upon increasing the solvent polarity when a CDMPC CSP was utilized. To understand the underlying mechanism governing these chiral separations, VCD was applied to study the structure of the ADMPC and CDMPC polymers and their conformational behaviors under chromatographic conditions. For the first time the conformations of the side chains of both polymers were revealed based on the VCD spectra along with DFT calculations. Furthermore, the interactions between the two analytes and the two CSPs were directly probed by VCD. By comparing the spectral differences of the two CSPs in the presence of the two analytes, the detailed interactions involving different functional groups associated with the chiral recognition were elucidated and thus explained the unusual reversal of elution order associated with increasing solvent polarity.  相似文献   

9.
A new calix[4]crown-5 macrocycle-bonded silica stationary phase (CL-CIMS) was prepared and applied at the same time to develop a chromatographic procedure to separate aromatic amines, phenols and drugs in this study. The chromatographic behaviors of the prepared stationary phase for these analytes were studied and compared with those of ODS (octadecylsilane). The effect of organic modifier content and pH of the mobile phase on retention and selectivity of these compounds were investigated. Some aromatic amines, phenols or drugs on CL-CIMS were successfully separated. The results show that CL-CIMS exhibits high selectivities for the above analytes in high aqueous mobile phases and a bright prospect in routine, fast separation of aromatic amines, phenols and drug compounds. From chromatographic data, it can be concluded that hydrophobic interaction is mainly responsible for the retention behavior as well as hydrogen-bonding interaction, π-π and dipole-dipole interaction.  相似文献   

10.
A two-dimensional ion chromatography (2D-IC) approach has been developed which provides greater resolution of complex samples than is possible currently using a single column. Two columns containing different stationary phases are connected via a tee-piece, which enables an additional eluent flow and independent control of eluent concentration on each column. The resultant mixed eluent flow at the tee-piece can be varied to produce a different eluent concentration on the second column. This allows analytes strongly retained on the first column to be separated rapidly on the second column, whilst maintaining a highly efficient, well resolved separation of analytes retained weakly on the first column. A group of 18 inorganic anions has been separated to demonstrate the utility of this approach and the proposed 2D-IC method provided separation of this mixture with resolution of all analytes greater than 1.3. Careful optimisation of the eluent profiles on both columns resulted in run times of less than 28 min, including re-equilibration. Separations were performed using isocratic or gradient elution on the first column, with an isocratic separation being used on the second column. Switching of the analytes onto the second column was performed using a gradient pulse of concentrated eluent to quickly elute strongly retained analytes from the first column onto the second column. The separations were highly repeatable (RSD of 0.01–0.12% for retention times and 0.08–2.9% for peak areas) and efficient (typically 8000–260,000 plates). Detection limits were 3–80 ppb.  相似文献   

11.
何世伟  黄忠平  朱岩 《色谱》2013,31(12):1146-1153
碳纳米管(CNTs)作为一种新型的功能材料,具有优异的物理、化学和机械性能,已经在分析化学领域得到了广泛的关注和应用。通过填充法或原位化学气相沉积法,可制备CNTs气相色谱固定相;将CNTs沉积在硅胶微球或有机聚合物基质微球表面,可制备填充式CNTs液相色谱固定相;通过包埋共聚法将CNTs嵌入聚合物整体柱内,可制备毛细管CNTs液相色谱整体柱。本文主要综述了近年来CNTs(单壁碳纳米管和多壁碳纳米管)用于色谱固定相制备的研究现状,包括气相色谱及液相色谱,并对该领域今后的发展进行展望。  相似文献   

12.
This work reports the preparation of monolithic zirconia chiral columns for separation of enantiomeric compounds by capillary electrochromatography (CEC). Using sol–gel technology, a porous monolith having interconnected globular-like structure with through-pores is synthesized in the capillary column as a first step in the synthesis of monolithic zirconia chiral capillary columns. In the second step, the surface of the monolith is modified by coating with cellulose tris(3,5-dimethylphenylcarbamate) (CDMPC) as the chiral stationary phase to obtain a chiral column (CDMPCZM). The process of the preparation of the zirconia monolithic capillary column was investigated by varying the concentrations of the components of the sol solution including polyethylene glycol, water and acetic acid. CDMPCZM is mechanically stable and no bubble formation was detected with the applied current of up to 30 μA. The enantioseparation behavior of the CDMPCZM columns was investigated by separating a set of 10 representative chiral compounds by varying the applied voltage and pH and organic composition of the aqueous organic mobile phases.  相似文献   

13.
A sol–gel titania poly(tetrahydrofuran) (poly-THF) coating was developed for capillary microextraction hyphenated on-line with high-performance liquid chromatography (HPLC). Poly-THF was covalently bonded to the sol–gel titania network which, in turn, became chemically anchored to the inner surface of a 0.25 mm I.D. fused silica capillary. For sample preconcentration, a 38-cm segment of the sol–gel titania poly-THF coated capillary was installed on an HPLC injection port as a sampling loop. Aqueous samples containing a variety of analytes were passed through the capillary and, during this process, the analytes were extracted by the sol–gel titania poly-THF coating on the inner surface of the capillary. Using isocratic and gradient elution with acetonitrile/water mobile phases, the extracted analytes were desorbed into the on-line coupled HPLC column for separation and UV detection. The sol–gel titania poly-THF coating was especially efficient in extracting polar analytes, such as underivatized phenols, alcohols, amines, and aromatic carboxylic acids. In addition, this coating was capable of extracting moderately polar and nonpolar analytes, such as ketones and polycyclic aromatic hydrocarbons. The sol–gel titania poly-THF coated capillary was also able to extract polypeptides at pH values near their respective isoelectric points. Extraction of these compounds can be important for environmental and biomedical applications. The observed extraction behavior can be attributed to the polar and nonpolar moieties in the poly-THF structure. This coating was found to be stable under extremely low and high pH conditions—even after 18 h of exposure to 1 M HCl (pH ≈0.0) and 1 M NaOH (pH ≈14.0).  相似文献   

14.
Monolithic columns have been prepared with a novel bonded silica stationary phase, tetradecylamine bonded silica (TDAS), and used in pressurized capillary electrochromatography (pCEC). The monolithic silica column matrix was prepared by a sol-gel process and then chemically modified with the spacer (3-glycidoxypropyl)trimethoxysilane and tetradecylamine. The introduced embedded polar amine groups dominated the charge on the surface of the monolithic stationary phase and generated an EOF from cathode to anode under acidic conditions. The tetradecyl hydrophobic chains in TDAS provide chromatographic interactions. The chromatographic characteristics of the prepared monolithic column were studied. Some aromatic compounds including alkylbenzenes, aromatic hydrocarbons, phenols, and anilines were successfully separated on the TDAS monolithic column in pCEC mode. As expected, the TDAS monolithic stationary phases exhibit typical reversed-phase electrochromatographic behavior toward neutral solutes due to the introduced tetradecyl groups. Hydrophobic as well as electrophoretic migration processes within the monoliths were observed in the separation of basic anilines. Symmetrical peaks can be obtained for anilines because the embedded polar amine groups on the surface can effectively shield the adsorption of positively charged analytes onto the stationary phase.  相似文献   

15.
A method is described for the synthesis of rigid, macroporous polymers (monoliths) to be used as stationary phases in capillary electrochromatography (CEC). The procedure reproducibly results in columns with good mechanical and chemical stability. Once the procedure was optimized, it yielded the desired CEC columns in nearly 100% of the cases. The batch-to-batch standard deviation of the migration of the electroosmotic flow (EOF) marker for nine randomly chosen columns was 5%. The polymerization is carried out inside the capillary, an aqueous phase is used as solvent. Monomers based on acrylamides with varying hydrophilicity were used to introduce the interactive moieties together with piperazine diacrylamide as cross-linker and vinylsulfonic acid as provider of the charged, EOF-producing moieties. The pore size of the monoliths was adjusted by adding varying amounts of ammonium sulfate to the reaction mixture. In this manner, the average pore size of a given monolith could be reproducibly adjusted to values ranging from 50 nm to 1.3 microm. The procedure was optimized for four particular types of monoliths, which differed in hydrophobicity. The latter was adjusted by introducing suitable co-monomers, such as alkyl chain-bearing molecules, into the monolithic structure. Attempts to systematically investigate the chromatographic behavior of the monolithic stationary phases were made, using a model mixture of aromatic compounds as sample. The standard deviations for the run-to-run reproducibility of the retention times for unretained and retained analytes were <1.5%. Flat Van Deemter curves were measured even at elevated flow-rates (2 mm/s). Plate heights between 10 and 15 microm were measured in this range. The retention order was taken as the principal indication for the chromatographic mode. The separation was found to be governed neither by pure reversed-phase nor by pure normal-phase chromatography, even on monoliths, where large amounts of C6 ligands had been introduced.  相似文献   

16.
The reduction of analysis time, cost, and improvement of separation efficiency are the main requirements in the development of high‐throughput assay methods in bioanalysis. It can be achieved either by ultra‐high‐performance liquid chromatography (UHPLC) using stationary phases with small particles (<2 μm) at high back pressures or by using opposite direction—monolithic stationary phases with low back pressures. The application of new types of monolithic stationary phases for UHPLC is a novel idea combining these two different paths. The aim of this work was to test the recently introduced second‐generation of monolithic column Chromolith® HighResolution for UHPLC analysis of liposoluble vitamins in comparison with core‐shell and fully porous sub‐2 μm columns with different particle sizes, column lengths, and shapes. The separation efficiency, peak shape, resolution, time of analysis, consumption of mobile phase, and lifetime of columns were calculated and compared. The main purpose of the study was to find a new, not only economical option of separation of liposoluble vitamins for routine practice.  相似文献   

17.
1-Allyl-3-butylimidazolium bromide ionic liquid [AyBIm]Br was prepared and used for the modification of mercaptopropyl-functionalized silica through surface radical chain-transfer addition. The obtained ionic liquid-modified silica (SiImBr) was characterized by elemental analysis, infrared spectroscopy, NMR spectroscopy, and thermogravimetric analysis. The selective retention behaviours of polycyclic aromatic hydrocarbons (PAHs) including some positional isomers were investigated using SiImBr as a stationary phase in reversed-phase liquid chromatography. The results showed that SiImBr presented multiple interactions including hydrophobic, π–π, and ion–dipole interactions during the separation of PAHs and dipolar compounds. However, it is proposed that π–π and ion–dipole interactions play important roles in the separation of PAHs and dipolar compounds. These results indicate that the ionic liquid-modified silica stationary phase is promising for future applications. A commercially available monomeric octadecylated silica (ODS) column and a custom-made poly(styrene)-grafted silica (Sil-Stn) column were used as references.  相似文献   

18.
Monolithic stationary phases based on poly(ethylene glycol) diacrylates for capillary electrochromatography were developed. Several poly(ethylene glycol) diacrylates (Mn 250, 575, and 700) were used as single monomers and the resulting columns were carefully compared. Methanol and ethyl ether were selected as porogenic solvents, and in all cases ultraviolet radiation was selected as initiation method to prepare polymeric monoliths. The influence of the monomer chain length and ratio monomer/porogen on the morphological and electrochromatographic properties of the resulting monoliths was investigated. Several families of compounds with different polarity (alkyl benzenes, organophosphorous pesticides, benzoic acid derivatives, and sulfonamides) were selected to evaluate the performance of the fabricated monolithic columns. The best results were obtained for poly(ethylene glycol) diacrylate 700 monoliths affording efficiencies of 144 000 plates/m for retained polar aromatic small molecules and excellent reproducibility in column preparation (RSD values below 2.5%).  相似文献   

19.
Two cyclodextrin-based chiral stationary phases have been prepared by immobilization of functionalized mono-6-azido-β-CD derivatives to alkynyl modified silica via “click” chemistry and applied to the HPLC enantioseparation of various chiral compounds. The perphenylcarbamated CD CSP (CCP-CSP) exhibited excellent chiral recognition of a wide range of analytes including racemic aryl alcohols, flavonoids, bendroflumethiazide, atropine and some β-blockers. Methanol proved to be a better organic modifier than acetonitrile for most of the analytes with the exception of bendroflumethiazide. The “click” chemistry immobilized permethylated CD CSP (CCM-CSP) afforded poor chiral recognition for most analytes, but could resolve non-aromatic ionone derivatives which were not separated on CCP-CSP. These results suggest that resolution with cyclodextrin derived CSPs depend on a complex interplay of ‘host’–‘guest’ inclusion, hydrogen bonding, π–π and hydrophobic interactions.  相似文献   

20.
The easy shrinkage and swelling of polymer monolithic column when exposed to mobile phase with different polarity is a problem that cannot be ignored. To overcome this drawback, a convenient aqueous two‐phase polymerization approach was used to prepare poly (polyethylene glycol diacrylate, PEGDA) monolithic porous layer open tubular (mono‐PLOT) columns (150 μm). The poly(PEGDA) mono‐PLOT column with homogeneous polymer porous layer was synthesized successfully. A maximum plate number of 41,500 plates per meter for allyl thiourea was obtained under a velocity of 1.8 mm/s. Several kinds of polar molecule were separated on the proposed mono‐PLOT column and a typical hydrophilic interaction retention mechanism was observed. High speed separation of benzoic acids was also carried out, baseline separation of five benzoic acids was successfully achieved within 5 min with a 70 cm mono‐PLOT column at 50°C. Furthermore, the resulting PLOT column was also successfully applied to separate standard analytes of three DNA oxidative damage products and RNA‐modified nucleosides and four chlorophenols. At last, the column could separate alcohols, alkanes, and aromatic isomers via GC. It had more than 20,000 plates per meter for butanol – higher than commercial coatings open tubular columns.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号