首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 337 毫秒
1.
 A selective complexometric method for the determination of mercury(II) in the presence of associated metal ions is reported, based on the selective masking ability of 2-mercaptopropionylglycine (MPGH2) towards mercury. Mercury, along with other associated metal ions, is first complexed with excess of EDTA and the surplus EDTA is back titrated at pH 5–6 (hexamine buffer) with standard zinc sulfate solution using xylenol orange as indicator. An aqueous 1% solution of MPGH2 is then added to displace EDTA selectively from the Hg-EDTA complex and the released EDTA is titrated with the same standard zinc sulfate solution. Reproducible and accurate results are obtained for 4–85 mg of mercury with a relative error of ≤ 0.26% and coefficient of variation not exceeding 0.42%. The interferences of various cations and anions are studied. The method is used for the analysis of mercury in its complexes and alloy samples. Received August 30, 2000. Revision January 15, 2001.  相似文献   

2.
 A simple, rapid and accurate complexometric method is proposed for the determination of titanium(IV) where sodium potassium tartrate or ascorbic acid were used as masking agents. In the presence of diverse metal ions, titanium is first complexed with excess of EDTA and surplus EDTA is then titrated at pH 5–6 with zinc sulfate, xylenol orange being used as indicator. An excess of 5% aqueous sodium potassium tartrate is then added to displace the complexed EDTA from the Ti-EDTA complex quantitatively, which is titrated with zinc sulfate. Also, ascorbic acid may be used as the releasing agent. The methods work well in the range 1–53 mg of Ti(IV) for sodium potassium tartrate with relative errors ± 0.28% and standard deviations ≤ 0.16 mg. For ascorbic acid the range is 1.00–30.00 mg of Ti(IV) with relative errors of ± 0.40% and standard deviations of ≤ 0.05 mg Received October 9, 2001; accepted August 2, 2002  相似文献   

3.
 An indirect complexometric method is described for the determination of zinc(II) using 2,2′-bipyridyl as masking agent. Zinc(II) in a given sample solution is initially complexed with an excess of EDTA and surplus EDTA is titrated with lead nitrate solution at pH 5.0–6.0 (hexamine), using xylenol orange as indicator. An excess of 2,2′-bipyridyl is then added, the mixture shaken well and the EDTA released from the Zn-EDTA complex is titrated with standard lead nitrate solution. Results are obtained for 3–39 mg of Zn with relative errors ≤ 0.5% and standard deviations ± 0.06 mg. The interference of various ions are studied. The method is applied for the determination of zinc in its alloys and ores. Received October 27, 1998. Revision June 10, 1999.  相似文献   

4.
A complexo-titrimetric method for the determination of copper(II) in the presence of other metal ions is described, based on the selective masking ability of 2-mercaptoethanol towards copper(II). Copper and other ions in a given sample solution are initially complexed with an excess of EDTA and the surplus EDTA is titrated with zinc sulfate solution at pH 5.0–6.0 (hexamine), using xylenol orange as indicator. A known excess of 2-mercaptoethanol solution (10%) is then added, the mixture is shaken well and the released EDTA from the Cu-EDTA complex is titrated against standard zinc sulfate solution. The interferences of various ions are studied and the method is applied to the determination of copper in its ores, alloys and complexes. Reproducible and accurate results are obtained for 2.5–40 mg of Cu with relative errors 0.4% and standard deviations 0.04 mg.  相似文献   

5.
A complexo-titrimetric method for the determination of mercury(II) in the presence of other metal ions is described, based on the selective masking ability of sulphite ion towards Hg(II). Mercury in a given sample solution is initially complexed with a known excess of EDTA and the surplus EDTA titrated with zinc sulphate solution at pH 5.0–6.0 (hexamine), using xylenol orange (or methylthymol blue) as indicator. An excess of solid sodium sulphite is then added to decompose the Hg(II)-EDTA complex and the released EDTA is titrated with standard zinc sulphate solution. Reproducible and accurate results are obtained for 9.9–99 mg Hg with relative errors < 0.35% and standard deviations < 0.05 mg. The effects of various cations and anions are studied.  相似文献   

6.
 A new method for the complexometric determination of Bi in the presence of co-ions using 2-mercaptoethanol as selective masking agent has been proposed. Bismuth along with other ions in a given sample solution are initially complexed with excess of EDTA. The pH of the solution is adjusted to 5.0–6.0 using solid hexamine (10 ± 2 g) and the remaining uncomplexed EDTA is titrated with lead-nitrate solution using xylenol orange indicator. A known excess of 2-mercaptoethanol solution (5% alcoholic) is then added, the mixture is shaken well and the released EDTA from the Bi(III)-EDTA complex is titrated against standard lead-nitrate solution. The method is applied to the determination of bismuth in Wood’s alloy. Reproducible and accurate results are obtained for 2–40 mg of bismuth with relative errors ≤ 0.5% and standard deviations ≤ 0.04 mg. Received January 15, 1999. Revision March 29, 1999.  相似文献   

7.
An indirect complexo-titrimetric method is described for the determination of palladium in the presence of other metal ions, L-histidine being used as the masking agent. Palladium(II) and other metal ions are initially complexed with an excess of EDTA and the surplus EDTA titrated with standard zinc sulfate solution at pH 4.5–5.5 using xylenol orange as indicator. An excess of 1 % L-histidine solution is then added, and the released EDTA is titrated with standard zinc sulfate solution. Accurate and reproducible results were obtained for 2–15 mg of Pd with relative errors 0.4% and standard deviations < 0.02mg. Sn(IV) and Au(III) interfere, but can be easily masked. The method is successfully applied for the determination of palladium(II) in alloy compositions.  相似文献   

8.
A selective complexometric method is described for the determination of palladium, sodium nitrite being used as masking reagent. Palladium(II) in a given sample solution is initially cornplexed with an excess of EDTA and the surplus EDTA is titrated with zinc sulfate solution at pH 4.5–5.5 (acetic acid-sodium acetate buffer), using xylenol orange as indicator. An excess of sodium nitrite is then added, the mixture is shaken well and the EDTA released from the Pd-EDTA complex is titrated with a standard zinc sulfate solution. Results are obtained for 2.5–27.5 mg of Pd with relative errors 0.5% and standard deviations 0.05 mg. The interferences of various ions are studied. The method is applied for the determination of palladium(II) in alloys and complexes.  相似文献   

9.
A simple and accurate complexometric method is proposed for the determination of Tl(III) using semicarbazide hydrochloride as a releasing agent. In the presence of diverse metal ions, thallium is complexed first with a known excess of EDTA, and the surplus EDTA is then titrated with standard zinc sulfate at pH 5.0–6.0 (hexamine) using xylenol orange indicator. An excess of 5% aqueous neutral solution of semicarbazide hydrochloride is then added and the released EDTA is titrated against standard zinc sulfate solution. The method works well in the range 2–50 mg of Tl(III) with relative errors < 0.5%, standard deviations 0.05mg and coefficient of variation 0.4%. The method is applied for the determination of thallium content in complexes and alloy compositions  相似文献   

10.
A complexo-titrimetric method for the determination of mercury(II) in the presence of other metal ions is described based on the selective masking ability of sodium nitrite. Mercury and other ions are initially complexed with an excess of EDTA and the surplus EDTA is titrated with Pb(NO3)2 solution at pH 5.0–6.0 using xylenol orange as indicator. An excess of solid NaNO2 is then added to decompose the Hg(II)-EDTA complex and the released EDTA is titrated with standard Pb(NO3)2 solution. Accurate results were obtained for 10–65 mg of mercury with relative errors <0.3% and standard deviations < 0.03 mg. Sn(IV) and Pd(II) interfere but can be easily masked. The method is applied for the determination of Hg(II) in its alloy compositions and complexes.  相似文献   

11.
An EDTA titration method is described for the determination of copper(II) in the presence of other ions based on the selective masking ability of 2,2′-bipyridyl. Copper and other ions in a given sample solution are initially complexed with an excess of EDTA and the surplus EDTA is titrated with lead nitrate solution at pH 5.0–6.0 (hexamine), using xylenol orange as an indicator. A known excess of 2,2′-bipyridyl solution (1% in 50% alcohol) is then added, the mixture is shaken well and the released EDTA from the Cu–EDTA complex is titrated against standard lead nitrate solution. The interference of various ions are studied and the method is applied to the determination of copper in its ores and alloys. Reproducible and accurate results are obtained for 2.54–25.40 mg of copper with S.D. values <0.04 mg.  相似文献   

12.

Background  

A complexometric method based on selective masking and de-masking has been developed for the rapid determination of aluminium, lead and zinc from the same solution in glass and glass frit samples. The determination is carried out using potassium cyanide to mask zinc, and excess disodium salt of EDTA to mask lead and aluminium. The excess EDTA was titrated with standard Mn(II)SO4 solution using Erichrome Black-T as the indicator. Subsequently selective de-masking agents – triethanolamine, 2,3-dimercaptopropanol and a formaldehyde/acetone mixture – were used to determine quantities of aluminium, lead and zinc in a stepwise and selective manner.  相似文献   

13.
A complexometric method for the determination of cadmium(II) in presence of other metal ions is described based on the selective masking ability of 2-mercaptoethanol towards cadmium(II). Cadmium and other ions in a given sample solution are initially complexed with excess of EDTA and the surplus EDTA is titrated with lead nitrate solution at pH 5.0–6.0 (hexamethylentetramine), using xylenol orange as indicator. A known excess of 2-mercaptoethanol solution (10% alcoholic) is then added, the mixture is shaken well and the released EDTA from the Cd-EDTA complex is titrated against standard lead nitrate solution. The interferences of various ions are studied and the method is applied to the determination of cadmium in its complexes. Reproducible and accurate results are obtained for 3.5–25mg of Cd with relative errors 0.65% and standard deviations 0.06 mg.  相似文献   

14.
A simple, rapid, accurate, and selective complexometric method is proposed for the determination of palladium(II). Palladium(II), with associated diverse metal ions, is first complexed by adding a known excess of EDTA, and the uncomplexed EDTA is back titrated with lead nitrate solution in acetic acid-sodium acetate buffer (pH 5.0–6.0) until the end-point. Thiosemicarbazide (1%) solution in water is added to displace EDTA from the Pd-EDTA complex. The released EDTA is then titrated with the lead nitrate solution. Reproducible and accurate results are obtained in the concentration range of 1–10 mg of palladium with a relative error of less than 0.4% and a standard deviation of less than 0.02. The interference of many commonly associated metal ions was also studied. Advantages of this method over other complexometric methods of palladium determination are high-lighted.  相似文献   

15.
A simple and accurate method has been developed for selective determination of mercury in alkaline solution. It involves the addition of an excess of EDTA to the mercury solution, titration of unreacted EDTA with a standard zinc solution, and then addition of N-allylthiourea solution at pH ? 9. By heating, the mercury-EDTA chelate is decomposed selectively, mercury sulfide is precipitated, and the EDTA freed is again titrated with standard zinc solution. Eriochrome Black T is used as indicator. Interference of some cations is discussed.  相似文献   

16.
A simple, rapid and accurate complexometric method for the determination of palladium(II) is proposed, based on the selective masking property of thioacetamide towards palladium(II). In the presence of diverse metal ions, palladium(II) is complexed with excess of EDTA and the surplus EDTA is back titrated at pH 5-5.5 (acetic acid-sodium acetate buffer) with standard lead nitrate solution using xylenol orange as indicator. An excess of a 0.5% aqueous solution of thioacetamide is then added to displace EDTA from Pd(II)-EDTA complex. The released EDTA is titrated with the same standard lead nitrate solution as before. Reproducible and accurate results are obtained in the concentration range 0.5 mg - 17.80 mg of palladium with relative error of +/- 0.16% and coefficient of variation not exceeding 0.26%. The effect of diverse ions is studied. The method is used for the determination of palladium in its complexes, catalysts and synthetic alloy mixtures.  相似文献   

17.
A simple, rapid and selective complexometric method is proposed for the determination of mercury(II). Mercury(II) and other related metal ions are first complexed with an excess of EDTA and the surplus EDTA is back-titrated with a standard lead nitrate solution at pH 5.0–6.0 (hexamine buffer) using xylenol orange as an indicator. A 0.2% solution of 2-thiazolinethiol in acetone is then added to displace EDTA from the Hg(II)-EDTA complex. The released EDTA is titrated with a standard lead nitrate solution as before. Reproducible and accurate results are obtained in the range of 0.8 g l?1?15.8 g l?1 of mercury with a relative error less than ±0.25% and a coefficient of variation (n = 6) not higher than 0.28%. The interference of various ions was studied and the method was employed for the analysis of mercury in its synthetic alloy mixtures and in complexes.  相似文献   

18.
Narayana B  Gajendragad MR 《Talanta》1988,35(9):719-720
A simple, rapid and selective complexometric method is proposed for the determination of mercury(II). Mercury(II) is first complexed with a known excess of EDTA and the surplus EDTA is back-titrated at pH 5.0-6.0 with lead nitrate, Xylenol Orange being used as indicator. 2-Imidazolidinethione is then added to displace EDTA from the Hg-EDTA complex quantitatively and the EDTA released is titrated with lead nitrate. Reproducible and accurate results are obtained for 2-75 mg of mercury, with a relative error of less than 0.3% and standard deviation of less than 0.04 mg.  相似文献   

19.
NARAYANA  B.  KUCHINAD  T. Girish  GAJENDRAGAD  M. R. 《中国化学》1992,10(5):412-416
A simple, rapid, accurate and selective complexometric method is proposed for the determina-tion of mercury(Ⅱ). Mercury(Ⅱ) is first complexed with a known excess of EDTA and the surplusEDTA is back-titrated at pH 5. 0--6. 0 with lead nitrate, xylenol orange being used as indicator. Hexa-hydropyrimidine-2-thione (HPT) is then added to displace EDTA from the Hg-EDTA complex quan-titatively and the EDTA released is titrated with lead nitrate. Reproducible and accurate results areobtained for 2--55 mg of mercury, with a relative error of less than 0. 5% and standard deviation ofless than 0.04.  相似文献   

20.
An indirect complexometric method is described for the determination of cadmium(II), 1,10-phenanthroline being used as masking agent. Cadmium(II) in a given sample solution is initially complexed with an excess of EDTA and the surplus EDTA is titrated with lead nitrate solution at pH 5.0–6.0 (hexamine), using xylenol orange as indicator. An excess of 1,10-phenanthroline is then added and the EDTA released from the Cd-EDTA complex is titrated with standard lead nitrate solution. Results are obtained for 1.5–57 mg of Cd with relative errors 0.90% and standard deviations 0.06 mg. Cu(II), Co(II), Hg(II), Ni(II), Zn(II), Pd(II), Tl(III), Au(III) and Sn(IV) interfere, but can be easily masked. The method is applied for the determination of cadmium in synthetic alloy solutions.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号