首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 265 毫秒
1.
A new hexane-in-water microemulsion was investigated as buffer in microemulsion EKC (MEEKC). At difference with other microemulsions, the addition of cosurfactant was not necessary to stabilize the microemulsion. The proposed microemulsion was successfully used to achieve electrophoretic separation of seven antibiotics including nitroimidazoles, cephapirin and tetracyclines. Selectivity and separation efficiency achieved in MEEKC were compared with MEKC. MEEKC technique proved to be more efficient than MEKC for performing the separation of the analytes and the presence of microemulsions was found to be critical to achieve the separation of tetracyclines. The proposed microemulsion also points out that solvents with high volatility, such as hexane, can be stabilized and used as a microemulsion of SDS.  相似文献   

2.
Yang X  Xia Y  Tao C  Liao Y  Zuo Y  Liu H 《Electrophoresis》2007,28(11):1744-1751
An investigation of the basic factors which govern the microemulsion EKC (MEEKC) and MEKC for the separation of four benzoylurea (BU) insecticides and their four analogs was carried out. In MEEKC, the separation of eight BU compounds was optimized by changing the microemulsion composition, such as concentration of SDS, octane, n-butanol, and isopropanol percentages, as well as capillary temperature. Separation optimization was also carried out for MEKC, showing that ACN and a high level of another additive gamma-CD were needed to achieve effective separation of these analytes. Although separation with baseline resolution was achieved by either MEEKC or MEKC methods, the separation selectivity resulting from the proposed MEEKC method was completely different from that of MEKC. In addition, analytical time in MEEKC was longer than that in MEKC, but in view of theoretical plate numbers, detection limits, and reproducibility, both methods were effective for the analysis of BU insecticides and their analogs.  相似文献   

3.
The migration behaviour of isoquinoline, quinoline, and methyl derivatives of quinoline in different capillary electrophoretic modes has been systematically investigated. Optimised separation conditions were established by varying the key parameters (solvent, pH, temperature, surfactant concentration, core phase) for aqueous and non‐aqueous capillary zone electrophoresis (NACE), micellar electrokinetic chromatography (MEKC) with anionic or non‐ionic micelles (SDS, Brij 35), and microemulsion electrokinetic chromatography (MEEKC) with charged or uncharged microemulsion droplets. A separation of all quinolines could be achieved by MEEKC with charged droplets, by MEKC or by formamide‐based NACE. Comparing the separations with respect to separation selectivity, substantial changes in migration order could be observed between the different techniques. Regarding separation efficiency, the number of theoretical plates and limits of detection (LOD) have been compared. The best LODs were achieved using SDS as surfactant in MEKC, followed by MEEKC.  相似文献   

4.
In this work, the influences of ionic liquid (IL) as a modifier on microemulsion microstructure and separation performance in MEEKC were investigated. Experimental results showed that synergetic effect between IL 1‐butyl‐3‐methylimidazolium tetrafluoro‐borate (BmimBF4) and surfactant SDS gave a decreased CMC. With increment of IL in microemulsion, negative ζ potential of the microdroplets reduced gradually. The influence of IL on the dimensions of microdroplet was complicated. At BmimBF4 less than 8 mM, IL made microemulsion droplet smaller in size. While at BmimBF4 more than 10 mM, the size increased and reached to a maximum value at 12 mM, where the microdroplets were larger than that without IL. After that, the micreodroplet size decreased again. Relative fluorescence intensity of the first vibration band of pyrene to the third one (I1/I3) enhanced as IL was added to microemulsion, which indicated that this addition increased environmental polarity in the inner core of microdroplets. Prednisone, hydrocortisone, prednisolone, hydrocortisone acetate, cortisone acetate, prednisolone acetate, and triamcinolone acetonide were analyzed with MEEKC modified with IL to evaluate the separation performance. Cortisone acetate and prednisolone acetate could not be separated at all in typical microemulsion. The seven analytes could be separated by the addition of 10 mM BmimBF4 into the microemulsion system. The method has been used for analysis of corticosteroids in cosmetic samples with simple extraction; the recoveries for seven analytes were between 86 and 114%. This method provides accuracy, reproducibility, pretreatment simplicity, and could be applied to the quality control of cosmetics.  相似文献   

5.
A comparison between chiral cyclodextrin‐modified microemulsion electrokinetic chromatography (CD‐MEEKC) and cyclodextrin‐modified micellar electrokinetic chromatography (CD‐MEKC) for the enantiomeric separation of esbiothrin was carried out. For both methods, the separation conditions were optimized by varying CD types and concentration, running buffer pH and compositions, organic modifiers, and temperature. The optimal CD‐MEEKC conditions were 0.8% n‐heptane, 2.3% SDS, 6.6% n‐butanol, 90.3% 10 mM sodium tetraborate containing 3% (w/v, the ratio of CD mass to microemulsion volume) methyl‐β‐cyclodextrin, pH 10, 25°C. The optimized CD‐MEKC conditions were 3.3% SDS, 96.7% 10 mM sodium tetraborate containing 5% (w/v) β‐CD, pH 10, 25°C. The difference in physicochemical properties of the buffer and CDs resulted in different optimal CD type. The competitive distribution between the microemulsion (or micelle) and chiral CD contributed to the chiral separation. Both methods provided excellent separation (Rs ~? 3) with similar migration time (ca. 15 min). CD‐MEEKC provided higher separation efficiencies (>300000) than CD‐MEKC (>200000). The LODs for CD‐MEEKC and CD‐MEKC were 4.7 μg/mL and 3.2 μg/mL, respectively. The RSDs of migration time and peak area for CD‐MEEKC were slightly higher than for CD‐MEKC. Both the demonstrated CD‐MEEKC and CD‐MEKC methods provided high efficiencies, low LODs, and reproducible enantioseparations of esbiothrin.  相似文献   

6.
Li Q  Chang CK  Huie CW 《Electrophoresis》2005,26(17):3349-3359
The effects of organic solvents on the capillary electrophoresis (CE) separation of a number of important biological porphyrin methyl esters - six weakly basic, hydrophobic cyclic tetrapyrroles possessing two and four to eight methyl ester groups around the periphery of the porphyrin ring - were investigated in the mode of micellar electrokinetic chromatography (MEKC), microemulsion electrokinetic chromatography (MEEKC), and nonaqueous CE. In aqueous MEKC, partial separation of the six neutral porphyrin methyl esters was obtained with an organic modifier (acetonitrile) in the concentration range between 20 and 40%, in which sodium dodecyl sulfate (SDS) molecules might be present in the form of SDS micelles and/or SDS micelle-like aggregates. Relatively stable SDS micelles can be formed in nonaqueous MEKC using formamide as the separation medium, but the separation of the target analytes remained unsatisfactory. Improved resolution of all six porphyrin methyl esters was obtained using MEEKC with the running buffer consisting of 0.8% w/w n-heptane (oil phase), 2.25% w/w SDS and 1.0% w/w Brij 35 (mixed surfactant), 6.6% w/w 1-butanol (cosurfactant), and 30% v/v 2-propanol (second cosurfactant), but reproducibility in terms of peak areas for certain porphyrins (especially uroporphyrin I octamethyl ester) was found to be very poor. Best separation performances were achieved with nonaqueous CE separations in which the weakly basic porphyrin methyl esters were protonated under strongly acidic conditions (e.g., using 10 mM perchloric acid) in mixed organic solvents. For example, using a 50:50 mixture of methanol and acetonitrile as the separation medium, baseline separation of all six (positively charged) porphyrin methyl esters can be obtained within 3 min and the average precision (RSD, N = 13) in terms of migration time and peak area were 0.55 and 2.16%, respectively.  相似文献   

7.
Cao Y  Ni X  Sheng J 《Journal of chromatography. A》2011,1218(18):2598-2603
Recently, 1-butanol modified MEKC was proven to be similar to MEEKC in separation performance. In the present work, typical microemulsion containing 0.8% n-octane/3.3% SDS/6.6% 1-butanol/20 mM borax buffer and corresponding swollen micelle without n-octane were used to compare their microdroplet structures including hydrodynamic radius, electrokinetic potential ζ and charge density at the hydrodynamic shear surface, as well as microenvironment polarity in the interior of the microdroplets. Three kinds of corticosteroids were separated with MEEKC and 1-butanol modified MEKC to assess their separation performances. The experiment results showed that both microstructure and separation performance in microemulsion and in swollen micelle systems were alike, no matter whether oil phase n-octane was present. The environment polarity in the core of swollen micelle was slightly higher than in the microemulsions, and both of them were higher than in n-octane medium. Furthermore, the influences of SDS and 1-butanol concentration on microstructures were measured in details. Increasing the amount of SDS, hydrodynamic radius decreased in microemulsion but increased in swollen micelle. On the contrary, ζ and shear surface charge density changed in the reverse trends. With increment of 1-butanol concentration, the hydrodynamic radius increased dramatically in microemulsions, whereas decreased slightly in swollen micelle. Even though using n-octane as oil core was not a key factor, microemulsions and swollen micelle as pseudostationary phase in EKC should not be exactly the same.  相似文献   

8.
In this study, microemulsion electrokinetic chromatography (MEEKC) and micellar electrokinetic chromatography (MEKC) were compared for their abilities to separate and detect thirteen phenolic compounds (syringic acid, p-coumaric acid, vanillic acid, caffeic acid, gallic acid, 3,4-dihydroxybenzoic acid, 4-hydroxybenzoic acid, (+)-catechin, (-)-epigallocatechin, (-)-epicatechin gallate, (-)-epigallocatechin gallate, (-)-epicatechin, and (-)-gallocatechin), and two other ingredients (caffeine and theophylline) in teas and grapes. Separation of phenolic compounds was improved by changing the SDS concentration for MEEKC, but the SDS concentration rarely affected the resolution for MEKC. Organic modifier (acetonitrile or methanol) was found to markedly influence the resolution and selectivity for both MEEKC and MEKC systems. In addition, a higher voltage and a higher column temperature improved the separation efficiency without any noticeable reduction in resolution for MEEKC whereas they caused a poor resolution for the MEKC system. Although separations with baseline resolution were achieved by the optimized MEEKC and MEKC methods, the separation selectivity resulting from the proposed MEEKC method was completely different from that of MEKC.  相似文献   

9.
建立了以离子液体为添加剂的反向微乳毛细管电泳(IL-MEEKC)法分离测定化妆品中氢化可的松、泼尼松和醋酸氢化可的松3种糖皮质激素的方法.微乳毛细管电泳的最佳缓冲体系组成为:2.4% SDS+6.6%正丁醇+0.5%正辛烷+35 mmol/L BMIM-BF4+20 mmol/L磷酸二氢钠缓冲液(pH 2.2);运行电...  相似文献   

10.
The separation of neutral hydrophobic corticosteroids (cortisone, cortisone acetate, hydrocortisone, hydrocortisone acetate, prednisolone and prednisolone acetate) by microemulsion electrokinetic chromatography (MEEKC) was studied. In the preparation of microemulsion, heptane was the solvent, n-butanol the co-surfactant and, as anionic surfactants, sodium dodecyl sulfate (SDS) or taurodeoxycholic acid sodium salt (STDC) were employed. Using an acidic running buffer, (phosphate pH 2.5) a strong suppression of the electroosmotic flow (EOF) was observed; this resulted in a fast anodic migration of the analytes partitioned into the negatively charged microemulsion droplets. Under these conditions, STDC showed better separation of corticosteroids than the conventional SDS; however, the use of a single anionic surfactant did not provide the required selectivity. The addition of the neutral surfactant polyoxyethylene glycol octadecyl ether (Brij 76) significantly altered the migration of each analytes allowing a better tuning of separation; however, in order to obtain adequate resolution between couples of adjacent critical peaks, the addition of neutral cyclodextrins (CDs) was found to be essential. This apparently complex system (CD-MEEKC), was optimized by studying the effect of the most important parameters affecting separation: STDC concentration, Brij 76 concentration, nature and concentration of cyclodextrins. Following a rational step-by-step approach, the optimised conditions providing the complete separation of the analytes were found to be: 4.0% STDC, 2.5% Brij 76, 6.6% n-butanol, 1.36% heptane and 85.54% of a solution 5 mM beta-CD in 50 mM phosphate buffer (pH 2.5). The optimized system was preliminary applied to the detection of corticosteroids related substances at impurity level and it could be considered a useful orthogonal alternative to HPLC methods.  相似文献   

11.
The resolution (R(s)) of hydrophobic analytes in microemulsion EKC (MEEKC) and MEKC with suppressed electroosmosis was investigated using bisphenol-A-diglycidyl ether and its derivatives (BADGEs) as test analytes. Separation scales were compared using our equation for the resolution, R(s)= (square rootN/4)(alpha-1)/(1+K(2)),where k is the retention factor, alpha the selectivity (alpha = k(2)/k(1) for k(2) > or = k(1)>0), and N the average efficiency. At given concentrations of SDS and organic cosolvent in the buffer, in comparison with MEKC, MEEKC was found to provide better resolution of BADGEs, mainly due to the significantly smaller k in MEEKC, but not the greater alpha in MEEKC, while a comparable range of N. Significantly improved resolution of BADGEs was obtained with increase in the concentration of organic cosolvent in the MEEKC and MEKC buffers, while small change in R(s) with the SDS concentration in a range of 100-180 mM. In addition, a decrease in temperature or voltage resulted in slightly better R(s).  相似文献   

12.
In this study, separation and determination of nine preservatives ranging from hydrophilic to hydrophobic properties, which are commonly used as additives in various pharmaceutical and cosmetic products, by micellar electrokinetic chromatograpy (MEKC) and microemulsion electrokinetic chromatography (MEEKC) were compared. The effect of temperature, buffer pH, and concentration of surfactant on separation were examined. In MEKC, the separation resolution of preservatives improved markedly by changing the sodium dodecyl sulfate concentration. Temperature and pH of running buffers were used mainly to shorten the magnitude of separation time. However, in order to detect all preservatives in a single run in a MEEKC system, a microemulsion of higher pH was needed. The separation resolution was improved dramatically by changing temperature, and a higher concentration of SDS was necessary for maintaining a stable microemulsion solution, therefore the separation of the nine preservatives in MEEKC took longer than in MEKC. An optimum MEKC method for separation of the nine preservatives was obtained within 9.0 min with a running buffer of pH 9.0 containing 20 mM SDS at 25 degrees C. A separation with baseline resolution was also obtained within 16 min using a microemulsion of pH 9.5 which composed of SDS, 1-butanol, and octane, and a shorter capillary column at 34 degrees C. Finally, the developed MEKC and MEEKC methods determined successfully preservatives in various cosmetic and pharmaceutical products.  相似文献   

13.
Recent applications of microemulsion electrokinetic chromatography   总被引:1,自引:0,他引:1  
Huie CW 《Electrophoresis》2006,27(1):60-75
Compared to MEKC, the presence of a water-immiscible oil phase in the microemulsion droplets of microemulsion EKC (MEEKC) gives rise to some special properties, such as enhanced solubilization capacity and enlarged migration window, which could allow for the improved separation of various hydrophobic and hydrophilic compounds, with reduced sample pretreatment steps, unique selectivities and/or higher efficiencies. Typically, stable and optically clear oil-in-water microemulsions containing a surfactant (SDS), oil (octane or heptane), and cosurfactant (1-butanol) in phosphate buffer are employed as separation media in conventional MEEKC. However, in recent years, the applicability of reverse MEEKC (water-in-oil microemulsions) has also been demonstrated, such as for the enhanced separation of highly hydrophobic substances. Also, during the past few years, the development and application of MEEKC for the separation of chiral molecules has been expanded, based on the use of enantioselective microemulsions that contained a chiral surfactant or chiral alcohol. On the other hand, the application of MEEKC for the characterization of the lipophilicity of chemical substances remains an active and important area of research, such as the use of multiplex MEEKC for the high-throughput determination of partition coefficients (log P values) of pharmaceutical compounds. In this review, recent applications of MEEKC (covering the period from 2003 to 2005) are reported. Emphases are placed on the discussion of MEEKC in the separation of chiral molecules and highly hydrophobic substances, as well as in the determination of partition coefficients, followed by a survey of recent applications of MEEKC in the analysis of pharmaceuticals, cosmetics and health-care products, biological and environmental compounds, plant materials, and foods.  相似文献   

14.
Separation and determination of water- and fat-soluble vitamins by micellar (MEKC) and microemulsion electrokinetic chromatography (MEEKC) are compared. MEKC is only useful in the quantitative analysis of water-soluble vitamins when sodium dodecylsulfate (SDS) is used as the surfactant. However, the separation of mixtures containing water- and fat-soluble vitamins is only achieved by MEEKC using a microemulsion prepared by mixing SDS as the surfactant, butanol as the co-surfactant, octane as the non-polar modifier and propanol as the second co-surfactant. The injection time and the solvent used for the dilution of samples have a significant effect on the analysis of lypophilic compounds. The most reproducible results in the analysis of fat-soluble vitamins are obtained by using the same microemulsion electrolyte as the solvent for samples and an injection time of 10 s.  相似文献   

15.
A novel microemulsion based on sodium bis(2-ethylhexyl) sulfosuccinate (AOT) was developed for the simultaneous determination of natural and synthetic estrogens by microemulsion EKC (MEEKC). The microemulsion system consisted of 1.4% w/w AOT, 1.0% w/w octane, 7.0% w/w 1-butanol and 90.6% w/w 20 mM sodium salt of 3-(cyclohexylamino)-2-hydroxy-1-propanesulfonic acid (CAPSO) and 10 mM phosphate buffer at pH 12.5. A baseline resolution in the separation of estrone, 17beta-estradiol, estriol, estradiol 17-hemisuccinate, etinilestradiol, estradiol 3-benzoate, and estradiol 17-valerate was achieved in comparison to the traditional MEEKC system with SDS in less than 15 min. The optimized electrophoretic conditions included the use of an uncoated-silica capillary of 60 cm of total length and 75 microm id, an applied voltage of 25 kV, a temperature of 25 degrees C and 214 UV-detection. Parameters of validation such as specificity, linearity, accuracy, LOD, LOQ and robustness were evaluated according to international guidelines. Due to its simplicity, accuracy, and reliability, the proposed method can be an advantageous alternative to the traditional methodologies for the analysis of natural and synthetic estrogens in different pharmaceutical forms.  相似文献   

16.
Yu LS  Xu XQ  Huang L  Ling JM  Chen GN 《Electrophoresis》2008,29(3):726-733
A selective and sensitive method of microemulsion EKC (MEEKC) with electrochemical detection (ED) was developed for separation and determination of 14 flavonoids. In order to obtain the better stability for the studied flavonoids, oil (ethyl acetate) with low interfacial surface tension was employed as organic solvent. A running buffer composed of 0.9% (w/v, 30 mM) SDS, 0.9% (w/v, 21 mM) sodium cholate (SC), 0.9% (w/v, 121 mM) butan-1-ol, 0.6% (w/v, 68 mM) ethyl acetate, and 98.2% v/v 10 mM Na(2)B(4)O(7)-20 mM H(3)BO(3) buffer (pH 7.5) was applied for the separation of flavonoids. Under the optimum conditions, the relationship between peak currents and analyte concentrations was linear over about 1.3 and 1.7 orders of magnitude with detection limits (defined as S/N = 3) ranging from 0.02 to 0.5 microg/mL for all analytes. This method was applied for the determination of flavonoids in real samples with simple extraction procedures, and the assay results were satisfactory.  相似文献   

17.
A novel microemulsion electrokinetic chromatography (MEEKC) method for separating and determining two sesquoterpene lactones, alantolactone (AL) and isoalantolactone (IAL), in Radix inulae and Liuwei Anxian San has been developed. The effects of several important factors such as internal organic phases, concentration of microemulsion, concentration of acetonitrile, injection time and running voltage were systematically investigated to determine the optimum conditions. The optimum microemulsion system was composed of n-hexane (0.32% w/w), SDS (1.24% w/w), 1-butanol (2.64% w/w), acetonitrile (10% w/w) and 10 mm sodium tetraborate buffer (85.80% w/w, pH 9.2). The applied voltage was 20 kV. The analytes were detected at 214 nm. Regression equations revealed linear relationships (correlation coefficients 0.9950 for AL and 0.9946 for IAL) between the peak area of each analyte and the concentration. The limits of detection (defined as a signal-to-noise ratio of about 3) were approximately 0.45 microg/mL for AL and 0.56 microg/mL for IAL. The levels of the analytes were successfully determined with recoveries ranging from 98.2 to 104.3%. Furthermore, a simple and effective extraction method, with methanol in an ultrasonic water bath for 60 min, was used for sample preparing. Also, MEEKC was compared with micellar electrokinetic chromatography (MEKC) and shown better separation results.  相似文献   

18.
A mixture of nine biphenyl nitrile compounds with high hydrophobicity and similar structures was successfully separated by microemulsion electrokinetic chromatography (MEEKC) within 30 rain. The buffer system contained 100 mmol/L sodium dodecyl sulfate (SDS), 80 mlnol/L sodium cholate (SC), 0.81% heptane, 7.5% n-butanol, 10% acetonitrile and 10 mmol/L borate. The addition of SC, organic modifiers, sample preparation and temperature all showedremarkable effect on the separation. Meanwhile, the MEEKC method was briefly compared with micellar electrokinetic chromatography (MEKC) method.  相似文献   

19.
With the implementation of recombinant DNA technology in the pharmaceutical industry, some synthetic insulins have been developed in order to improve the therapy of diabetes. These analogues differ only slightly in the amino acid sequence, therefore displaying a great challenge for analytical chemistry. Within the work presented in this paper, capillary zone electrophoresis (CZE), micellar electrokinetic chromatography (MEKC) with sodium dodecylsulphate (SDS) as micelle-forming agent, and microemulsion electrokinetic chromatography (MEEKC) with microemulsions consisting of SDS, n-octane and 1-butanol were investigated for the separation of human insulin and five synthetic analogues. Best results were achieved with a solvent-modified MEKC system consisting of 100 mM sodium dodecyl sulphate and 15% acetonitrile in 10 mM borate buffer (pH 9.2). A similar system based on perfluorooctanoic acid as micelle-forming agent in ammonium acetate (pH 9.2) was successfully employed for the hyphenation with a quadrupole/time-of-flight mass spectrometer via a sheath-flow interface. In this case, detection limits at 10 mg/L could be achieved.  相似文献   

20.
A microemulsion electrokinetic chromatographic (MEEKC) method was developed for the separation of six catechins, specific marker phytochemicals of Cistus species. The MEEKC method involved the use of sodium dodecyl sulfate (SDS) as surfactant, heptane as organic solvent and butan-1-ol as co-solvent. In order to have a better stability of the studied catechins, the separation was performed under acidic conditions (pH 2.5 phosphate buffer). The effects of SDS concentration and of the amount of organic solvent and co-solvent on the analyte resolution were evaluated. The optimized conditions (heptane 1.36% (w/v), SDS 2.31% (w/v), butan-1-ol 9.72% (w/v) and 50 mM sodium phosphate buffer (pH 2.5) 86.61% (w/v)) allowed a useful and reproducible separation of the studied analytes to be achieved. These conditions provided a different separation profile compared to that obtained under conventional micellar electrokinetic chromatography (MECK) using SDS. The method was validated and applied to the determination of catechin and gallocatechin in lyophilized extracts of Cistus incanus and Cistus monspeliensis.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号