首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Developments in ion mobility spectrometry–mass spectrometry   总被引:4,自引:0,他引:4  
Ion mobility spectrometry (IMS) has been used for over 30 years as a sensitive detector of organic compounds. The following is a brief review of IMS and its principles with an emphasis on its usage when coupled to mass spectrometry. Since its inception, IMS has been interfaced with quadrupole, time-of-flight, and Fourier-transform ion cyclotron resonance mass spectrometry. These hybrid instruments have been employed for the analysis of a variety of target analytes, including biomolecules, explosives, chemical warfare degradation products, and illicit drugs.  相似文献   

2.
A novel, specific and sensitive non-immunological liquid chromatography–mass spectrometry (LC–MS) based assay has been developed to detect and quantify trace levels of wheat gluten in food and consumer products. Detection and quantification of dietary gluten is important, because gluten is a principle trigger of a variety of immune diseases including food allergies and intolerances. One such disease, celiac sprue, can cause intestinal inflammation and enteropathy in patients who are exposed to dietary gluten. At present, immunochemistry is the leading analytical method for gluten detection in food. Consequently, enzyme-linked immunosorbent assays (ELISAs), such as the sandwich or competitive type assays, are the only commercially available methods to ensure that food and consumer products are accurately labeled as gluten-free. The availability of a comprehensive, fast and economic alternative to the immunological ELISA may also facilitate research towards the development of new drugs, therapies and food processing technologies to aid patients with gluten intolerances and for gluten-free labeling and certification purposes. LC–MS is an effective and efficient analytical technique for the study of cereal grain proteins and to quantify trace levels of targeted dietary gluten peptides in complex matrices. Initial efforts in this area afforded the unambiguous identification and structural characterization of six unique physiologically relevant wheat gluten peptides. This paper describes the development and optimization of an LC–MS/MS method that attempts to provide the best possible accuracy and sensitivity for the quantitative detection of trace levels of these six peptides in various food and consumer products. The overall performance of this method was evaluated using native cereal grains. Experimental results demonstrated that this method is capable of detecting and quantifying select target peptides in food over a range from 10 pg/mg to 100 ng/mg (corresponding to approximately 0.01–100 ppm). Limits of detection (LOD) and quantification (LOQ) for the six target peptides were determined to range from 1 to 30 pg/mg and 10–100 pg/mg respectively. Reproducibility of the assay was demonstrated by evaluation of calibration data as well as data collected from the analysis of quality control standards over a period of four consecutive days. The average coefficient of determination (R2) for each peptide was consistently found to be >0.995 with residuals ranging from approximately 80% to 110%. Spike recovery data for each peptide in various matrices was evaluated at a concentration level near the approximate LOQ for each, as well as at higher concentration levels (30 and 60 ng/mg). The average range of accuracy of detection for all peptides at the lower concentration level was determined to be 90% (±11), while accuracy at the 30 and 60 ng/mg levels was 98% (±5%) and 98% (±3%), respectively. The usefulness and capabilities of this method are presented in a practical application to prospectively screen a variety of common commercially available (native and processed) gluten-containing and gluten-free foods and products.  相似文献   

3.
The feasibility of a microfluidic-based liquid chromatography-electrospray ionization/mass spectrometric system (HPLC-Chip/ESI/MS) was studied and compared to a conventional narrow-bore liquid chromatography-electrospray ionization/mass spectrometric (LC-ESI/MS) system for the analysis of steroids. The limits of detection (LODs) for oxime derivatized steroids, expressed as concentrations, were slightly higher with the HPLC-Chip/MS system (50–300 pM) using an injection volume of 0.5 μL than with the conventional LC-ESI/MS (10–150 pM) using an injection volume of 40 μL. However, when the LODs are expressed as injected amounts, the sensitivity of the HPLC-Chip/MS system was about 50 times higher than with the conventional LC-ESI/MS system. The results indicate that the use of HPLC-Chip/MS system is clearly advantageous only in the analysis of low-volume samples. Both methods showed good linearity and good quantitative and chromatographic repeatability. In addition to the instrument comparisons with oxime derivatized steroids, the feasibility of the HPLC-Chip/MS system in the analysis of non-derivatized and oxime derivatized steroids was compared. The HPLC-Chip/MS method developed for non-derivatized steroids was also applied to the quantitative analysis of 15 mouse plasma samples.  相似文献   

4.
Mass spectrometry (MS) is a fundamental technique to identify compounds by their mass-to-charge ratio. It is known that MS can only detect target compounds when they are converted to ions in the gas phase. The ionization procedure is considered one of the most critical steps, and there are distinct techniques for it. One of them is electron ionization (EI), a widely used hard-ionization technique capable of generating several ions due to the excess energy employed. The existence of distinct ionization mechanisms turns EI capable of producing a fingerprint-like spectrum for each molecule. So, it is an essential technique for obtaining structural information. EI is often combined with chromatography to obtain a practical introduction of pretreated samples despite its excellent performance. EI–MS has been applied coupled with gas chromatography (GC) since the 1960s as both are very compatible. Currently, analytes of interest are more suitable for liquid chromatography (LC) analysis, so there are researchers dedicated to developing suitable interfaces for coupling LC and EI–MS. EI excels, as a reliable technique to fill the gap between GC and LC, possibly allowing them to coexist in a single instrument. In this work, the authors will present the fundamentals of EI–MS, emphasizing the development over the years, coupling with gas and LC, and future trends.  相似文献   

5.
This paper describes the development of an optimized method based on solid-phase extraction (SPE) followed by liquid chromatography–electrospray ionization tandem mass spectrometry (LC–MS/MS) for the simultaneous analysis of ten antibiotic compounds including tetracyclines, sulfonamides, macrolides and quinolones. LC–MS/MS sensitivity has been optimized by alterations to both LC and MS operations. Of the two high resolution columns tested, Waters Symmetry C18 endcapped and Agilent Zorbax Bonus-RP, the latter was found to show better performance in producing sharp peaks and clear separation for most of the target compounds. Optimization of the MS fragmentation collision and cone energy enhanced the peak areas of the target analytes. The recovery of the target compounds from water samples was most efficient on Waters Oasis HLB SPE cartridge, while methanol was shown to be the most suitable solvent for desorbing the compounds from SPE. In addition, acidification of samples prior to SPE was shown to enhance the recovery of the compounds. To ensure a satisfactory recovery, the flow rate through SPE should be maintained at ≤10 mL min−1. The method was successfully applied to the analysis of antibiotics from environmental water samples, with concentrations being <LOD in tap water, between <LOD to 28 ng L−1 in river water and between <LOD to 230 ng L−1 in sewage effluent.  相似文献   

6.
Four different organic solvents: dimethylformamide, 1,4-dioxane, n-propanol and ethanol were evaluated as alternative organic modifiers to acetonitrile for liquid chromatography (LC) separations. The aim was to establish common sets of chromatographic conditions that could be applied for LC hyphenation to inductively coupled plasma mass spectrometry (ICPMS) as well as to electrospray ionization MS (ESIMS). The approach was to evaluate candidate solvents that, compared to acetonitrile, potentially could give improved analytical performance (low solvent vapor loading, maximized analyte sensitivity and minimized carbon depositions on instrumental parts) in ICPMS analysis while retaining chromatographic and ESIMS performances. The study showed that dimethylformamide, 1,4-dioxane, n-propanol and ethanol all can be advantageous chromatographic modifiers for LC–ICPMS analysis, giving superior performance compared to acetonitrile. For the combined use of LC–ICPMS and LC–ESIMS with a common set of chromatographic conditions, n-propanol gave the best overall performance. The 195Pt+ signal in ICPMS was continuously monitored during a 0–60% organic solvent gradient and at 25% of organic modifier, 100% of the signal obtained at the gradient start was preserved for n-propanol compared to only 35% of the signal when using acetonitrile. Platinum detection limits were 5–8 times lower using n-propanol compared with acetonitrile. Signal-to-noise ratio in continuous ESIMS signal measurements was 100, 90 and 110 for a 100 μg/ml solution of leucine–enkephaline using acetonitrile, ethanol and n-propanol, respectively. Chromatographic efficiency in reversed phase separations was preserved for n-propanol compared to acetonitrile for the analysis of the whole protein cytochrome C and the peptide bacitracin on a column with particle and pore sizes of 5 μm and 300 Å, but slightly deteriorated for the separation of the peptides leucine–enkephaline and bacitracin on a 3 μm and 90 Å column as the peak width at half height for both peptides increased by a factor of two. The performance on the smaller dimensioned column could however be improved by running the separations at 40 °C.  相似文献   

7.
This review provides an overview of direct and indirect technologies to screen protein–ligand interactions with mass spectrometry. These technologies have as a key feature the selection or affinity purification of ligands in mixtures prior to detection. Specific fields of interest for these technologies are metabolic profiling of bioactive metabolites, natural extract screening, and the screening of libraries for bioactives, such as parallel synthesis libraries and small combichem libraries. The review addresses the principles of each of the methods discussed, with a focus on developments in recent years, and the applicability of the methods to lead generation and development in drug discovery.  相似文献   

8.
9.
The [M - nH + mNa](m-n)+ and [M - nH + mK](m-n)+ ions are common in the electrospray mass spectra of proteins and peptides. The feasibility of forming these ions in the gas phase via collision activation and/or ion-molecule reaction is investigated. Sodium and potassium affinities of the N-methylacetamide anion, the acetate anion, and the 1-propanamide anion have been calculated using density functional theory at the B3LYP/6-311+ +G(d,p) level of theory. These anions were chosen as models for the functional groups on a protein or peptide. These affinity values are then used to calculate reaction enthalpies of alkali hydroxides, chlorides, and hydrates with N-methylacetamide, acetic acid, the acetate anion, and 1-propanamine, model reactions that may lead to formation of the [M - nH + mNa](m-n) and [M - nH + mK](m-n)+ ions. It is found that a number of these reactions are exothermic or slightly endothermic (deltaH(o) < + 20 kcal/mol) and are accessible after collision activation in the lens region. The potential energy hypersurfaces of model reactions between NaOH and formamide as well as NaCl and formamide show relatively flat surfaces devoid of significant barriers.  相似文献   

10.
A matrix-assisted laser desorption ionization mass spectrometry (MALDI-MS) method was developed for the high throughput and robust qualitative profiling of alkaloids in Fuzi—the processed lateral roots of the Chinese herbal medicine Aconitum carmichaeli Debx (A. carmichaeli). After optimization, powdered roots – without any further sample preparation – could be used to screen for the presence of Aconitum alkaloids. Furthermore, the semi-quantitative potential of MALDI-MS was confirmed using liquid chromatography–mass spectrometry (LC–MS) as reference. In total over sixty alkaloids were detected by LC–MS and fifteen of them were tentatively identified. Both MALDI-MS and LC–MS analysis revealed significant variation in alkaloid content in different (commercial) samples. LC–MS analysis of three toxic alkaloids in 14 batches of Fuzi resulted in a variation of their concentrations expressed as RSDs of 138%, 99% and 221% for aconitine, hypaconitine and mesaconitine, respectively. The variation in concentrations (expressed as RSD) of about the ninety constituents detected were classified as follows: 13 constituents showed an RSD of 77–100%, 46 with an RSD of 100–150%, 21 with an RSD of 150–200% and 9 constituents with an RSD in concentration of 200–235%. These results demonstrate a strong difference in chemical composition of the various Fuzi and illustrate the necessity of adequate QA/QC procedures for both safety and efficiency of herbal medicine. The described analytical procedures for alkaloid profiling could play a role in these procedures.  相似文献   

11.
The term “wrong-way-round ionization” has been used in studies of electrospray ionization to describe the observation of protonated or deprotonated ions when sampling strongly basic or acidic solutions (respectively) where such ions are not expected to exist in appreciable concentrations in solution. Study of the dependence of ionization of the weak base caffeine on the electrospray capillary potential reveals three distinct contributors to wrong-way-round ionization. At near-neutral pH in solutions of low ionic strength, protonation of caffeine results from the surface enrichment of electrolytically produced protons in the surface layer of the droplets from which ions are desorbed. For solutions made strongly basic with ammonia, gas-phase proton transfer from ammonium ions can create protonated caffeine. These two mechanisms have been discussed previously elsewhere. For solutions of high ionic strength at neutral or high pH, the data suggest that discharge-induced ionization is responsible for the production of protonated caffeine. This mechanism probably accounts for some of the wrong-way-round ionization reported elsewhere.  相似文献   

12.
We have studied the mechanism of formation CN- secondary ions under Cs+ primary ion bombardment. We have synthesized 13C and 15N labeled polyglycine samples with the distance between the two labels and the local atomic environment of the 13C label systematically varied. We have measured four masses in parallel: 12C, 13C, and two of 12C14N, 13C14N, 12C15N, and 13C15N. We have calculated the 13C/12C isotope ratio, and the different combinations of the CN isotope ratios (27CN/26CN, 28CN/27CN, and 28CN/26CN). We have measured a high 13C15N- secondary ion current from the 13C and 15N labeled polyglycines, even when the 13C and 15N labels are separated. By comparing the magnitude of the varied combinations of isotope ratios among the samples with different labeling positions, we conclude the following: CN- formation is in large fraction due to recombination of C and N; the CO double bond decreases the extent of CN- formation compared to the case where carbon is singly bonded to two hydrogen atoms; and double-labeling with 13C and 15N allows us to detect with high sensitivity the molecular ion 13C15N-.  相似文献   

13.
The ability of ion mobility spectrometry coupled with mass spectrometry (IMS-MS) to characterize biological mixtures has been illustrated over the past eight years. However, the challenges posed by the extreme complexity of many biological samples have demonstrated the need for higher resolution IMS-MS measurements. We have developed a higher resolution ESI-IMS-TOF MS by utilizing high-pressure electrodynamic ion funnels at both ends of the IMS drift cell and operating the drift cell at an elevated pressure compared with that conventionally used. The ESI-IMS-TOF MS instrument consists of an ESI source, an hourglass ion funnel used for ion accumulation/injection into an 88 cm drift cell, followed by a 10 cm ion funnel and a commercial orthogonal time-of-flight mass spectrometer providing high mass measurement accuracy. It was found that the rear ion funnel could be effectively operated as an extension of the drift cell when the DC fields were matched, providing an effective drift region of 98 cm. The resolution of the instrument was evaluated at pressures ranging from 4 to 12 torr and ion mobility drift voltages of 16 V/cm (4 torr) to 43 V/cm (12 torr). An increase in resolution from 55 to 80 was observed from 4 to 12 torr nitrogen drift gas with no significant loss in sensitivity. The choice of drift gas was also shown to influence the degree of ion heating and relative trapping efficiency within the ion funnel.  相似文献   

14.
Diosmin is a flavonoid often administered in the treatment of chronic venous insufficiency, hemorrhoids, and related affections. Diosmin is rapidly hydrolized in the intestine to its aglicone, diosmetin, which is further metabolized to conjugates. In this study, the development and validations of three new methods for the determination of diosmetin, free and after enzymatic deconjugation, and of its potential glucuronide metabolites, diosmetin-3-O-glucuronide, diosmetin-7-O-glucuronide, and diosmetin-3,7-O-glucuronide from human plasma and urine are presented. First, the quantification of diosmetin, free and after deconjugation, was carried out by high-performance liquid chromatography coupled with tandem mass spectrometry, on an Ascentis RP-Amide column (150?×?2.1 mm, 5 μm), in reversed-phase conditions, after enzymatic digestion. Then glucuronide metabolites from plasma were separated by micro-liquid chromatography coupled with tandem mass spectrometry on a HALO C18 (50?×?0.3 mm, 2.7 μm, 90 Å) column, after solid-phase extraction. Finally, glucuronides from urine were measured using a Discovery HSF5 (100?×?2.1 mm, 5 μm) column, after simple dilution with mobile phase. The methods were validated by assessing linearity, accuracy, precision, low limit of quantification, selectivity, extraction recovery, stability, and matrix effects; results in agreement with regulatory (Food and Drug Administration and European Medicines Agency) guidelines acceptance criteria were obtained in all cases. The methods were applied to a pharmacokinetic study with diosmin (450 mg orally administered tablets). The mean C max of diosmetin in plasma was 6,049.3?±?5,548.6 pg/mL. A very good correlation between measured diosmetin and glucuronide metabolites concentrations was obtained. Diosmetin-3-O-glucuronide was identified as a major circulating metabolite of diosmetin in plasma and in urine, and this finding was confirmed by supplementary experiments with differential ion-mobility mass spectrometry.  相似文献   

15.
Monoacylglycerols (MAGs) are lipids found in trace amounts in plants and animal tissues. While they are widely used in various industrial applications, accurate determination of the regio-specific distribution is hindered by the lack of stable, commercially available standards. Indeed, unsaturated β-MAG (or Sn-2 MAG) readily undergoes isomerization into α-MAG (acyl chain is attached to the Sn-1 or the Sn-3 position). In the present study, we describe structural elucidation of α- and β-regio-isomers of monopalmitoyl-glycerol (MAG C16:0) as model compounds in their silylated forms using gas chromatography–mass spectrometry (GC–MS) with electronic impact (EI) ionization. MS fragmentation of α-MAG C16:0 is characterized by the loss of methylene(trimethylsilyl)oxonium (103 amu) and the consecutive loss of acyl chain yielding a fragment ion at m/z 205. The fragmentation pattern of β-MAG C16:0 shows a series of diagnostic fragments at m/z 218, 203, 191 and 103 that are not formed from the α-isomer and hereby enable reliable distinction of these regio-isomers. Possible fragmentation scenarios are postulated to explain the formation of these marker ions, which were also applied to characterize the regio-isomer composition of a complex mixture of MAG sample containing n-3 long-chain polyunsaturated fatty acids.  相似文献   

16.
Reversed-phase liquid chromatography on the nanoscale coupled to electrospray tandem mass spectrometry was used to analyse a mixture of four commercial glycan standards, and the method was further adapted to N-glycans enzymatically released from alpha-1-acid glycoprotein and immunoglobulin gamma. Glycans were permethylated to enable their separation by reversed-phase chromatography and to facilitate interpretation of fragmentation data. Prior to derivatization of glycans by permethylation, they were reduced to cancel anomerism because, although feasible, it was not desired to separate α- and β-anomers. The effect of supplementing chromatographic solvent with sodium hydroxide to guide adduct formation was investigated. Raising the temperature in which the separation was performed improved chromatographic resolution and affected retention times as expected. It was shown by using the tetrasaccharides sialyl Lewis X and sialyl Lewis A that reversed-phase chromatography could achieve the separation of methylated isobaric glycan analytes. Isobaric glycans were detected among the N-glycans of immunoglobulin gamma and further analysed by tandem mass spectrometry.  相似文献   

17.
Structural analysis of complex mixtures of oligosaccharides using tandem mass spectrometry is regularly complicated by the presence of a multitude of structural isomers. Detailed structural analysis is, therefore, often achieved by combining oligosaccharide separation by HPLC with online electrospray ionization and mass spectrometric detection. A very popular and promising method for analysis of oligosaccharides, which is covered by this review, is graphitized carbon HPLC–ESI-MS. The oligosaccharides may be applied in native or reduced form, after labeling with a fluorescent tag, or in the permethylated form. Elution can be accomplished by aqueous organic solvent mixtures containing low concentrations of acids or volatile buffers; this enables online ESI-MS analysis in positive-ion or negative-ion mode. Importantly, graphitized carbon HPLC is often able to resolve many glycan isomers, which may then be analyzed individually by tandem mass spectrometry for structure elucidation. While graphitized carbon HPLC–MS for glycan analysis is still only applied by a limited number of groups, more users are expected to apply this method when databases which support structural assignment become available.
Manfred WuhrerEmail:
  相似文献   

18.
Melanoma is most rapidly increasing in the white population and people with pheomelanin skin type are at high risk to develop melanoma. However, little is known about the pheomelanin structure and function, and further elucidation of this melanin is therefore an important task. A GC/MS method was developed based on hydriodic acid hydrolysis of pheomelanin in the urine. Derivatization was performed with ethyl chloroformate and ethanol:pyridine (4:1, v/v). N,O-Ethoxycarbonyl-ethyl esters were extracted with chloroform and analyzed by GC/MS. 4-Amino-3-hydroxyphenylalanine and 3-amino-4-hydroxyphenylalanine together with one benzothiazinone and two benzothiazole compounds were detected and identified in hydrolyzed samples of synthetic pheomelanin and melanin from the urine of a patient with melanoma. These findings strongly suggest that heterocyclic pheomelanin-type units are incorporated in the pigment structures.  相似文献   

19.
Non-enzymatic posttranslational modifications of bovine serum albumin (BSA) by various oxo-compounds (glucose, ribose, glyoxal and glutardialdehyde) have been investigated using high-performance liquid chromatography (HPLC) and capillary zone electrophoresis (CZE). Both of these methods used mass spectrometric (MS) detection. Three enzymes (trypsin, pepsin, proteinase K) were used to digest glycated BSA. The extent of modification depended on the selected oxo-compound. Reactivity increased progressively from glucose to glutardialdehyde (glucose < ribose < glyoxal < glutardialdehyde). Carboxymethylation of lysine (CML) was the main type of modification detected. The HPLC/MS method achieved higher coverage and a larger amount of CML was identified compared to CZE/MS.  相似文献   

20.
The presence of a peak centered near m/z 2862, observed for the first time for the caged dodecatungstate radical-anion, [W12O41]−·, enables distinguishing WO2 from WO3 by Laser Desorption Ionization mass spectrometry (LDI-MS). In addition to WO2, laser irradiation of dry deposits made from aqueous ammonium paratungstate, and calcium and lead orthotungstate also produce the [W12O41]−·. In contrast, spectra recorded from deposits made from aqueous Na2WO4, sodium metatungstate, and WO3, or non-aqueous calcium and lead orthotungstate, and ammonium paratungstate, failed to show the m/z 2862 peak cluster. These observations support the hypothesis that polycondensation reactions to form [W12O41]−· occur solely in the presence of water. Although dry spots are irradiated for ionization, the solvent used for sample preparation plays an important role on the chemical composition endowed to ions detected. For example, the m/z 2862 peak seen from deposits made from aqueous ammonium paratungstate, and calcium and lead orthotungstate, is absent in the spectra recorded either from pristine deposits or those derived from solutions made with organic solvents such as acetonitrile or ethanol.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号