首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 296 毫秒
1.
Due to regulation of the use of bisphenol A, several analogs serving as bisphenol A replacements have drawn substantial attention for their adverse health effects. To investigate their occurrence in humans and identify possible pollution sources, it is necessary to develop a sensitive method for total bisphenols detection. Thus, a method based on enzymolysis and liquid‐liquid extraction followed by molecularly imprinted polymer solid‐phase extraction and pre‐column derivatization with high‐performance liquid chromatography and tandem mass spectrometry was proposed. The developed method exhibited superior selectivity and sensitivity. The matrix effect can be eliminated to a great extent. The method detection limits for eight bisphenols were 0.05~0.19 ng/mL. Satisfactory recoveries (71~119%) were obtained by spiking bovine serum at three levels (0.8, 8 and, 20 ng/mL). The method was successfully applied to determine total bisphenols in the serum samples of children. Bisphenol A, bisphenol F, bisphenol S, bisphenol B and bisphenol F were detected with concentrations from below the method detection limit to 1.65, 0.45, 0.79, 2.04 and 0.17 ng/mL, respectively. These results indicate that bisphenol A remains the major pollutant among the studied bisphenols in children, whereas threats from bisphenol A analogs should also be monitored.  相似文献   

2.
In this study, an automated on-line solid-phase extraction coupled to fast liquid chromatography–tandem mass spectrometry (on-line SPE fast LC–MS/MS) method was developed for the simultaneous analysis of bisphenol A (BPA), bisphenol F (BPF), bisphenol E (BPE), bisphenol B (BPB) and bisphenol S (BPS) in canned soft drinks without any previous sample treatment. A C18 (12 μm particle size) loading column was used for the SPE on-line preconcentration before the liquid chromatography baseline separation of bisphenol compounds using a C18 Fused-Core™ (50 mm × 2.1 mm i.d.) column, which took less than 3 min. Gradient elution and heated electrospray were used to reduce matrix effect and improve ionization efficiency. To select the most intense and selective transitions, fragmentation studies were performed by multiple-stage mass spectrometry in an ion trap mass analyzer and tandem mass spectrometry in a triple quadrupole instrument, this latter instrument being used for quantitation in SRM mode. Quality parameters of the method were established and we obtained a simple, fast, reproducible (RSD values lower than 10%) and accurate (precision higher than 93%) method for the analysis of bisphenols in canned soft drinks at the ng L−1 level using matrix-matched calibration.  相似文献   

3.
Bisphenol A (BPA) is a widely used plasticizer that can contaminate food and the wider environment and lead to human exposure. In humans, it is mainly metabolized to bisphenol A-glucuronide (BPA-G) and eliminated in the urine. As BPA causes adverse physiological effects at low doses, it is necessary to document the toxicokinetics of both molecules for risk assessment. Because BPA-G is not available as an analytical standard, it is usually quantified after the assay of BPA, following an enzymatic hydrolysis with β-glucuronidase. With this approach, two separate assays are required for BPA and BPA-G quantification, which can lead to critical pitfalls in terms of accuracy and analysis time. To overcome this problem, we have developed a new method for the isolation and purification of BPA-G from urine by flash chromatography. Large amounts of BPA-G (1 g) were isolated and characterized by mass spectrometry and NMR. This BPA-G is suitable for an use as analytical standard and enabled us to develop a novel method for the simultaneous quantification of BPA and BPA-G in biological matrices by UPLC/MS/MS. It has also been used for in vivo toxicokinetic studies in sheep. The method of quantification was validated according FDA guidelines and used to monitor the time course of plasma and urine concentrations of BPA or BPA-G following their administration. The simultaneous quantification of BPA and BPA-G was compared to the commonly used method for urine and plasma samples. For plasma samples, the results obtained with the direct assay of BPA-G were similar to those obtained by quantification after enzymatic hydrolysis. With urine samples, the simultaneous quantification appeared to be more suitable than the hydrolysis method for the BPA-G determination.  相似文献   

4.
韩疏影  宋易霖  康安  邓海山  朱栋  池玉梅 《色谱》2019,37(11):1185-1192
基于在线富集-高效液相色谱-荧光法检测法,以C18柱分别作为富集柱和分析柱,经优化荧光波长、色谱分离和富集条件,建立了同时快速检测塑料儿童水杯浸出液中9种双酚类物质的方法。方法学考察结果显示,所建方法符合含量测定要求。9种双酚类物质在各自范围内线性关系良好,相关系数(r2)均大于0.998,检出限为0.13~66.7 ng/L。9种双酚类物质的回收率为90.7%~112.4%(RSD<11.3%,n=6)。结果显示,除双酚芴外,其他双酚类物质均有检出,浸出量随盛放时间增加而增大,高温多次浸泡后部分双酚类浸出量降低。该方法灵敏度高,操作简便,环境友好,可实现多种新型双酚类物质的同时快速检测。  相似文献   

5.
Supramolecular sorbents (hemimicelles/admicelles) are proposed for the extraction/preconcentration of bisphenols from aqueous environmental samples prior to their liquid chromatography/fluorimetric determination. A comparative study on the use of cetyltrimethylammonium bromide (CTABr)-coated silica and sodium dodecyl sulphate (SDS)-coated gamma-alumina as sorbent materials, is presented. Bisphenol A (BPA) and bisphenol F (BPF) were quantitatively retained on CTABr admicelles. Addition of tetrabutylammonium chloride (TBAC) to water samples was required to completely retain bisphenols on SDS-gamma-alumina. Retention on both sorbents occurred through hydrophobic and pi-cation interactions between the quaternary ammonium head group of the cationic amphiphile (CTABr or TBAC) and the aromatic rings of the target analytes. TBAC-SDS-gamma-alumina was the sorbent selected for the SPE of bisphenols on the basis of the lower elution volume required (1 ml of methanol) and the greater breakthrough volume allowed (400 ml), which permitted to reach practical detection limits of 10 and 15 ng/l for BPF and BPA, respectively. The proposed method was used to quantify bisphenol A and bisphenol B in wastewater samples from four sewage treatment plants. Recoveries obtained ranged between about 99 and 105% for raw wastewater and between 96 and 106% for treated wastewater.  相似文献   

6.
Pharmaceuticals have become major targets in environmental chemistry due to their presence in aquatic environments (following incomplete removal in wastewater treatment or point-source contaminations), threat to drinking water sources and concern about their possible effects to wildlife and humans. Recently several methods have been developed for the determination of drugs and their metabolites in the lower nanogram per litre range, most of them using solid-phase extraction (SPE) or solid-phase microextraction (SPME), derivatisation and finally gas chromatography mass spectrometry (GC-MS), gas chromatography tandem mass spectrometry (GC-MS/MS) and liquid chromatography electrospray tandem mass spectrometry (LC-ES/MS/MS). Due to the elevated polarity of non-steroidal anti-inflamatory drugs (NSAIDs), analytical techniques based on either liquid chromatography coupled to mass spectrometry (LC-MS) and gas chromatography coupled to mass spectrometry (GC-MS) after a previous derivatisation step are essential. The most advanced aspects of current GC-MS, GC-MS/MS and LC-MS/MS methodologies for NSAID analysis are presented.  相似文献   

7.
刘芳  孟桃于  陈练  吴雅君  熊顺  丁利 《色谱》2020,38(12):1381-1387
目前,双酚类化合物是重要的工业原料,常用来制造塑料(奶)瓶、幼儿用吸口杯、食品和饮料(奶粉)罐内侧涂层,其具有类似雌激素的作用,摄入低剂量的双酚类物质便会引起机体尤其婴幼儿体内激素水平的调节。建立了一种同时测定婴幼儿血清中双酚A(BPA)、双酚B(BPB)、双酚F(BPF)、双酚S (BPS)4种双酚类环境激素的高效液相色谱-串联质谱法(HPLC-MS/MS)。以甲基叔丁基醚(MTBE)为提取溶剂,采用液液萃取的方法进行样品处理,同时对影响4种双酚类环境激素提取效率的提取溶剂、提取时间、提取溶剂体积等影响因素进行了优化。100 μL血清样本在40 ℃下经400 μL MTBE提取15 min后,采用Waters ACQUITY UPLC BEH C18柱(50 mm×2.1 mm, 1.7 μm)进行分离,以超纯水和含0.5 mmol/L乙酸铵的甲醇溶液为流动相进行梯度洗脱,流速为0.2 mL/min,采用电喷雾电离、负离子模式扫描,在多反应监测(MRM)模式下测定。BPA、BPB、BPS在0.25~100 μg/L范围内线性关系良好,BPF在1~00 μg/L范围内线性关系良好,相关系数为0.9929~0.9959;方法的检出限分别为0.05、0.05、0.05、0.5 μg/L;在3个添加水平(5、20、100 μg/L)下,4种目标化合物的回收率为84.56%~104.43%,相对标准偏差小于10%。应用该方法对150例婴幼儿血清样品进行检测,结果表明:BPA、BPF、BPS在男童和女童血清中的检出率分别为90.67%和89.33%、6.67%和1.33%、5.33%和16.00%, BPB未被检出。该方法操作简单,回收率好,精密度高,适用于婴幼儿血清中4种双酚类环境激素的同时测定。  相似文献   

8.
Bisphenol A (BPA) is an environmental endocrine‐disrupting chemicals that is widely used in common consumer products. There is an increasing concern regarding human exposure to BPA owing to the potential adverse effects associated with its estrogenic activity. For assessing environmental exposure to BPA, it is essential to have a sensitive, accurate and selective analytical method, especially one that can detect low BPA levels in complex sample matrices. In this study, we developed and validated an accurate, sensitive, and robust liquid chromatography–tandem mass spectrometry method for simultaneous quantification of free BPA and BPA β‐d ‐glucuronide (BPA‐gluc) concentrations in human urine with only a single injection. Calibration curves were linear over a concentration range of 1–100 ng/mL for BPA and 10–1000 ng/mL for BPA‐gluc. The levels of the analytes were determined quantitatively with HPLC/ESI‐MS/MS by using negative electrospray ionization in the select ion monitoring mode and a pentaflouraphenyl propyl column. The validated method was applied to the analysis of spot urine specimens collected from randomly selected healthy human subjects. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

9.
We report a liquid chromatography/tandem mass spectrometry (LC/MS/MS) method for analyzing bisphenol A (BPA) and its halogenated derivatives. Since only tetrachlorobisphenol A and tetrabromobisphenol A (TBBPA) are commercially available, mono-, di- and trichlorobisphenol A were synthesized and purified in order to be used as analytical standards. This family of compounds was studied using electrospray ionization and an ion trap mass analyzer in order to characterize the new compounds and to propose fragmentation pathways. Multi-stage mass spectrometry was used to confirm the genealogical relationship between the ions. Some product ions were traced from MS/MS to MS(4) and the labelled compounds BPA-d(16) and TBBPA-(13)C(12) were used to assign some product ion structures. In general, the deprotonated molecule [M--H](-) loses a methyl and/or a halogen group during both MS/MS and MS(3), while the neutral loss of CO was also observed in MS(3) spectra. We selected the most intense and characteristic MS/MS transitions for LC/MS/MS analysis. LC separation was performed in a reversed-phase column; methanol/water (no additives) was used as the mobile phase in gradient elution mode; and BPA-d(16) was chosen as the internal standard. Solid-phase extraction (SPE) was used to pre-concentrate and to clean up water samples. The SPE LC/MS/MS method allows BPA and its halogenated derivatives to be detected at a few parts-per-billion (ppb) in surface water.  相似文献   

10.
Two unknown compounds were previously determined to be potential interferences in liquid chromatography/tandem mass spectrometry (LC/MS/MS) analysis of bisphenol A (BPA) in canned infant formula. Both yielded two identical MS/MS transitions to BPA. The identities of the unknowns were investigated using accurate mass LC/MS, LC/MS/MS, and elemental formula and structures proposed. Exact identities were confirmed through purification or synthesis followed by (1)H and (13)C nuclear magnetic resonance (NMR) experiments, as well as comparisons of one unknown with commercial standards. Comparisons of negative ion electrospray ionization (ESI) MS/MS and accurate mass spectra suggested both unknowns to be structurally identical (to BPA and each other). Positive ion ESI spectra confirmed both were larger molecules, suggesting that in the negative mode they likely fragmented to the deprotonated BPA ion in the source [corrected]. Elemental composition of positive ion accurate mass spectra and NMR analysis concluded the unknowns were oxidized forms of the known epoxy can coating monomer, bisphenol A diglycidyl ether (BADGE). One of the unknowns, 2,2-[bis-4-(2,3-dihydroxypropoxy)phenyl]propane, commonly known as BADGE*2H(2)O, is widely reported as an epoxy-phenolic can coating migrant, but has not been suggested to interfere with the MS/MS analysis of BPA. The other unknown, 2-[4-(2,3-dihydroxypropoxy)phenyl]-2-[4'-hydroxyphenyl]propane, or the oxidized form of bisphenol A monoglycidyl ether (BAMGE*H(2)O), has not been previously reported in food or packaging.  相似文献   

11.
Analytical methods for the determination of bisphenol A in food   总被引:2,自引:0,他引:2  
Food constitutes the primary route for human exposure to bisphenol A (BPA), one of the highest volume chemicals produced worldwide. The estrogenic properties of BPA, its wide dispersive use and the recent extensive literature describing low-dose BPA effects in animals, have raised concerns about its possible adverse effects on human health. A reliable health risk assessment of BPA relies basically on its unambiguous identification and accurate quantification in food, and the aim of the present review is to give an overview of the analytical methods reported so far for the determination of BPA in these matrices. Emphasis is placed on the main strategies developed for sample treatment, which usually consists of several laborious and time-consuming steps in order to achieve the required sensitivity and selectivity. Separation, identification and quantitation of BPA is today reliably made with mass spectrometric methods, namely liquid chromatography-mass spectrometry (LC-MS) and gas chromatography-mass spectrometry (GC-MS), and thus main attention is devoted to these techniques, but other methods using LC coupled to fluorescence or electrochemical detection, as well as immunochemical methods are also covered. Recent and expected future developments are discussed.  相似文献   

12.
A gas chromatography with mass spectrometry method has already been developed and published for the identification and quantification of 14 phthalates and five nonphthalate plasticizers in polyvinylchloride medical devices. In order to assay, in addition to plasticizers, bisphenols A and B possibly present in polyvinylchloride samples, this previous method was extended to the assay of these additional potential endocrine disruptors. Furthermore, as bisphenol A could also be present in polycarbonate samples, the method used for the polyvinylchloride sample was tested and validated for the assay of bisphenols A and B in polycarbonate medical devices. The separation of all compounds, including bisphenols A and B, is obtained on a cross‐linked 5%‐phenyl/95%‐dimethylpolysiloxane capillary column using a temperature gradient. For both plastics, samples are dissolved in tetrahydrofuran followed by a precipitation of the plastic by addition of ethanol. Results obtained point out residual bisphenol A amounts for polycarbonate samples ranging from 0.6 to 0.8% and for polyvinylchloride samples less or equal to 5 ppm. No bisphenol B was detected in the samples tested. For bisphenols A and B, mean recoveries obtained on spiked polyvinylchloride or polycarbonate sample preparations ranged from 87 to 108% in accordance with in‐house specification (80–110%).  相似文献   

13.
The presence of polybrominated diphenyl ethers (PBDEs) and their hydroxylated (OH-BDE) and methoxylated (MeO-BDE) analogs in humans is an area of high interest to scientists and the public due to their neurotoxic and endocrine disrupting effects. Consequently, there is a rise in the investigation of the occurrence of these three classes of compounds together in environmental matrices and in humans in order to understand their bioaccumulation patterns. Analysis of PBDEs, OH-BDEs, and MeO-BDEs using liquid chromatography-mass spectrometry (LC-MS) can be accomplished simultaneously, but detection limits for PBDEs and MeO-BDEs in LC-MS is insufficient for trace level quantification. Therefore, fractionation steps of the phenolic (OH-BDEs) and neutral (PBDEs and MeO-BDEs) compounds during sample preparation are typically performed so that different analytical techniques can be used to achieve the needed sensitivities. However, this approach involves multiple injections, ultimately increasing analysis time. In this study, an analytical method was developed for a “one-shot” analysis of 12 PBDEs, 12 OH-BDEs, and 13 MeO-BDEs using gas chromatography with tandem mass spectrometry (GC-MS/MS). This overall method includes simultaneous extraction of all analytes via pressurized liquid extraction followed by lipid removal steps to reduce matrix interferences. The OH-BDEs were derivatized using N-(t-butyldimethylsilyl)-N-methyltrifluoroacetamide (TBDMS-MTFA), producing OH-TBDMS derivatives that can be analyzed together with PBDEs and MeO-BDEs by GC-MS/MS in “one shot” within a 25-min run time. The overall recoveries were generally higher than 65%, and the limits of detection ranged from 2 to 14 pg in both breast milk and serum matrices. The applicability of the method was successfully validated on four paired human breast milk and serum samples. The mean concentrations of total PBDEs, OH-BDEs, and MeO-BDEs in breast milk were 59, 2.2, and 0.57 ng g−1 lipid, respectively. In serum, the mean total concentrations were 79, 38, and 0.96 ng g−1 lipid, respectively, exhibiting different distribution profiles from the levels detected in breast milk. This “one-shot” GC-MS/MS method will prove useful and cost-effective in large-scale studies needed to further understand the partitioning behavior, and ultimately the adverse health effects, of these important classes of brominated flame retardants in humans.  相似文献   

14.
The fragmentation of bisphenol A diglycidyl ether (BADGE), bisphenol F diglycidyl ether (BFDGE) and their derivatives was studied by electrospray ionization tandem mass spectrometry. Multiple-stage mass spectrometry and accurate mass measurements were combined to establish the fragmentation pathways. BADGEs and BFDGEs tend to form ammonium adducts under electrospray conditions which fragmented easily. The fragmentation of [M+NH(4)](+) for BADGEs started with the cleavage of the phenyl-alkyl bond, which was followed by the α-cleavage of the ether group to generate the characteristic product ions at m/z 135, [C(9)H(11)O](+), and m/z 107, [C(7)H(7)O](+). The fragmentation of the BFDGE isomer mixtures was studied by on-line reversed-phase liquid chromatography coupled to multiple-stage mass spectrometry (LC/MS(n)). Information obtained from product ion spectra for each BFDGE isomer and its comparison with the fragmentation pathway of BADGE allowed each isomer and the chromatographic elution order to be identified.  相似文献   

15.
建立了婴幼儿奶瓶中双酚A(BPA)迁移量的高效液相色谱-电喷雾串联质谱(HPLC-ESI-MS/MS)测定方法。奶瓶食品模拟浸泡液经过弗罗里硅土玻璃层析柱净化,高效液相色谱分离,采用选择反应性监测模式(SRM)检测。以一级质谱得到的准分子离子m/z 227作为母离子,进行二级质谱(MS2)分析。选择MS2的碎片离子m/z 212、133、93定性确证,m/z 212作为定量离子定量。实验优化了质谱条件,并对二级质谱碎裂机理和特征离子进行了研究。测定结果的相对标准偏差不大于8.2%(n=7),回收率在87.7%~105%之间;检出限为2μg/L,能够满足欧盟、美国等对奶瓶中双酚A的限制要求。该法已成功应用于婴幼儿奶瓶中BPA迁移量的测定。  相似文献   

16.
A high-performance liquid chromatography-ultraviolet method was developed for rapidly and simultaneously analyzing novel and typical bisphenols in building materials, including bisphenol S, diphenolic acid, bisphenol F, bisphenol E, bisphenol A, bisphenol B, bisphenol AF, bisphenol AP, bisphenol C, bisphenol FL, bisphenol Z, bisphenol BP, bisphenol M, and bisphenol P. By using a Kromasil 100–5 C18 column, these bisphenols were completely separated in 40 min via gradually increasing the concentration of methanol in the mobile phase from 45 to 80% during the elution process. In particular, this method achieved the synchronous analysis of bisphenol S, diphenolic acid, bisphenol FL, bisphenol BP, and bisphenol M through HPLC, which were difficult to separate and had to be identified and detected through mass spectrometry. The limits of detection of the method ranged from 0.002 to 0.040 mg/L for these 14 bisphenols, with a precision of less than 4.9% (n = 7, c = 0.05 mg/L). The analytical results for five types of building materials (phenolic, epoxy, polycarbonate, polyester, and polysulfone resins) indicated that the proposed method is appropriated for the rapid measurement of bisphenols in real samples.  相似文献   

17.
酚类环境雌激素的分析研究进展   总被引:27,自引:0,他引:27  
环境中分布或残留的化学物质对人类和野生动物的内分泌系统的不良影响已引起广泛关注。在已发现的数十种环境内分泌干扰物中,壬基苯酚、辛基苯酚、双酚A和2,4-二氯酚等以其相似的结构特征和类雌激素活性逐渐被划分为一类新的分析研究对象,称为酚类环境雌激素。本文综述了这些物质的主要来源和分布及其分析测定的研究进展,重点评述了一些新的分析技术如基体固相分散萃取法(MSPD)、分子印迹聚合物法(MIP)、荧光分子传感法(FMS)和生物识别-化学分析联用法等在上述物质的分析测定中的应用。比较了GC-MS和LC-MS等手段用于分析此类物质的优势和各自的局限性,并展望了这一领域未来的研究发展趋势。本文引用文献共54篇。  相似文献   

18.
A sensitive HPLC method with fluorescence detection was developed for the determination of bisphenol A (BPA) and bisphenol B (BPB) in human blood serum. The detection limits of the method were 0.18 and 0.20 ng/mL for BPA and BPB, respectively. A single‐step liquid–liquid extraction was used for the pre‐treatment of serum samples. The recoveries of BPA and BPB spiked to sera were 85.6 and 87.7%, respectively. The analyses of sera from both healthy and endometriotic women emphasized the absence of bisphenols in all the control cases (11 women), whereas BPA was found in 30 sera (51.7%) and BPB was found in 16 sera (27.6%) in the group of 58 patients with endometriosis; in nine of such sera BPA and BPB were present simultaneously. Only relatively to the sera quantitated, BPA concentrations ranged from 0.79 to 7.12 ng/mL (mean concentration 2.91 ± 1.74 ng/mL), whereas BPB concentrations ranged from 0.88 to 11.94 ng/mL (mean concentration 5.15 ± 4.16 ng/mL). Therefore, the presence of at least one of the two bisphenols was verified in a percentage as high as 63.8% in the sera from endometriotic women, suggesting the existence of a relationship between endometriosis and BPA and/or BPB exposure. Indeed, it is well known that bisphenols can work as xenoestrogens, owing to their structural similarity to natural and synthetic estrogens (e.g. estradiol and dietilstilbestrol). However, further studies are necessary to confirm this hypothesis and to assess the actual dose at which exposures to bisphenols are able to increase the sensitivity of the endometriotic cells to estradiol. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

19.
A procedure has been developed for the determination of bisphenol A (BPA) in foods by gas chromatography/mass spectrometry as 2,2-bis-(4-(isopropoxycarbonyloxy)phenyl)propane formed in the reaction with isopropyl chloroformate. Optimal conditions have been found for BPA derivatization, providing its quantitative conversion into diether derivative in aqueous media. The concentration of BPA has been determined in some samples of canned foods and beverages (from 2.15 to 42.91 ng/g). The detection limit is 0.05–0.1 ng/g.  相似文献   

20.
Bisphenol A (BPA) is well known for its use in plastic manufacture and thermal paper production despite its risk of health toxicity as an endocrine disruptor in humans. Since the publication of new legislation regarding the use of BPA, manufacturers have begun to replace BPA with other phenolic molecules such as bisphenol F (BPF) and bisphenol B (BPB), but there are no guarantees regarding the health safety of these compounds at this time. In this context, a very simple, cheap and fast surface-enhanced Raman scattering (SERS) method was developed for the sensitive detection of these molecules in spiked tap water solutions. Silver nanoparticles were used as SERS substrates. An original strategy was employed to circumvent the issue of the affinity of bisphenols for metallic surfaces and the silver nanoparticles surface was functionalized using pyridine in order to improve again the sensitivity of the detection. Semi-quantitative detections were performed in tap water solutions at a concentrations range from 0.25 to 20 μg L−1 for BPA and BPB and from 5 to 100 μg L−1 for BPF. Moreover, a feasibility study for performing a multiplex-SERS detection of these molecules was also performed before successfully implementing the developed SERS method on real samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号