首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 78 毫秒
1.
A liquid chromatography/tandem mass spectrometric (LC/MS/MS) analytical procedure for the quantification of eight proteolytic fragments from inter-alpha-trypsin inhibitor heavy chain 4 (ITIH(4)) in human plasma and serum has been developed. The eight peptide fragments only differ in length at the N-terminus, varying between 21 and 30 amino acid residues. Protein precipitation (PP) with acetonitrile was followed by solid-phase extraction (SPE) on C(2) columns to provide clean extracts. Chromatographic separation of the peptides was performed on a Symmetry 300 C(18) column (50 mm x 2.1 mm i.d., particle size 3.5 microm), using a water/methanol gradient containing 0.25% v/v formic acid. The triple quadrupole mass spectrometer was operated in the positive electrospray ionization (ESI(+)) mode, using multiple reaction monitoring (MRM) for detection. One stable-isotope-labeled analog and two structural analogs were used as internal standards. The method has been completely validated for plasma and partially for serum samples, yielding linear responses in a range up to 100 ng/mL. The lower limit of quantification (LLOQ) in plasma was +/-2 ng/mL for four ITIH(4)-derived peptides and +/-5 ng/mL for the others. The stabilities of the peptides in different environments have been extensively explored. Several peptides showed rapid degradation, especially in the biological matrix at ambient temperature, and preparation on ice was therefore required. The method has been applied for the analysis of several plasma and serum samples from patients with different cancer types. Copyright (c) 2008 John Wiley & Sons, Ltd.  相似文献   

2.
A reversed-phase high-performance liquid chromatographic method is described for the determination of hydroxy and peroxy acid derivatives of uroporphyrin in the plasma of patients with congenital erythropoietic porphyria. The porphyrins were extracted from the plasma with 20% trichloroacetic acid-dimethyl sulphoxide (1:1, v/v). The supernatant after centrifugation was chromatographed on a Hypersil-ODS column by gradient elution with 9% (v/v) acetonitrile in 1 M ammonium acetate buffer (pH 5.16) (solvent A) and 10% (v/v) acetonitrile in methanol (solvent B) as the gradient mixture. The method was also suitable for the preparative isolation of the porphyrins.  相似文献   

3.
李晶  徐济仓  李雪梅  周建光  朱岩  缪明明 《色谱》2012,30(8):816-821
建立了超高效液相色谱-二极管阵列检测器(UPLC-PDA)同时测定香精香料中14种禁限用物质的方法。样品经10%(v/v)甲醇水溶液(含1%(v/v)氨水)提取后进行UPLC测定。采用的色谱柱为Waters BEH C18柱(50 mm×2.1 mm, 1.7 μm),流动相为10 mmol/L乙酸铵(含0.1%乙酸)和乙腈,梯度洗脱,流速为0.2 mL/min,柱温为35 ℃,在200~500 nm范围内进行扫描检测。结果表明,该方法在12 min内可实现14种禁限用物质的分离和检测,在0.10~50 mg/L范围内具有较好的线性关系,各待测物的线性相关系数均大于0.995,检出限(以信噪比为3计)为0.32~2.51 mg/kg。在5、10、20 mg/L添加水平下待测物的平均回收率为93.0%~121.0%,相对标准偏差为0.51%~4.50%。该方法操作简易,灵敏度高,线性相关性好,重复性佳,可以满足国内对于香精香料样品中禁限用物质的检测要求。  相似文献   

4.
A specific and sensitive direct-injection high performance liquid chromatography electrospray ionization tandem mass spectrometry (HPLC/ESI-MS/MS) method has been developed for the rapid identification and quantitative determination of olanzapine, clozapine, and N-desmethylclozapine in human plasma. After the addition of the internal standard dibenzepin and dilution with 0.1% formic acid, plasma samples were injected into the LC/MS/MS system. Proteins and other large biomolecules were removed during an online sample cleanup using an extraction column (1 x 50 mm i.d., 30 microm) with a 100% aqueous mobile phase at a flow rate of 4 mL/min. The extraction column was subsequently brought inline with the analytical column by automatic valve switching. Analytes were separated on a 5 microm Symmetry C18 (Waters) analytical column (3.0 x 150 mm) with a mobile phase of acetonitrile/0.1% formic acid (20:80, v/v) at a flow rate of 0.5 mL/min. The total analysis time was 6 min per sample. The inter- and intra-assay coefficients of variation for all compounds were <11%. By eliminating the need for extensive sample preparation, the proposed method offers very large savings in total analysis time.  相似文献   

5.
A new liquid chromatography-mass spectrometry (LC-MS)-based method coupled with pressurized liquid extraction (PLE) as an efficient sample preparation technique has been developed for the quantification and fingerprint analysis of Solanum xanthocarpum. Optimum separations of the samples were achieved on a Waters MSC-18 XTerra column, using 0.5% (v/v) formic acid in water (A) and acetonitrile (ACN):2-propanol:formic acid (94.5:5:0.5, v/v/v) (B) as mobile phase. The separation was carried out using linear gradient elution with a flow rate of 1.0mL/min. The gradient was: 0min, 20% B; 14min, 30% B; 20min, 30% B; 27min, 60% B and the column was re-equilibrated to the initial condition (20% B) for 10min prior to next injection. The steroidal glycoalkaloids (SGAs) which are the major active constituents were isolated as pure compounds from the crude methanolic extract of S. xanthocarpum by preparative LC-MS and after characterization were used as external standards for the development and validation of the method. Extracts prepared by conventional Soxhlet extraction, PLE and ultrasonication were used for analysis. The method was validated for repeatability, precision (intra- and inter-day variation), accuracy (recovery) and sensitivity (limit of detection and limit of quantitation). The purpose of the work was to develop a validated method, which can be used for the quantification of SGAs in commercialized S. xanthocarpum products and the fingerprint analysis for their routine quality control.  相似文献   

6.
A high-performance liquid chromatographic method for the determination of wogonoside in plasma of rats administrated orally with the traditional Chinese medicinal preparation Huang-Lian-Jie-Du decoction was developed. Sample preparation was carried out by protein precipitation with a mixture of acetonitrile and methanol (1:1, v/v). The extracted sample was separated on a Hypersil C(18) (150 x 5 mm i.d., 5 microm) analytical column by linear gradient elution using 0.05% (v/v) phosphoric acid (containing 5 mm sodium dihydrogen phosphate) and acetonitrile as mobile phase at a flow rate of 1.5 mL/min. The eluate was detected using a UV detector at 276 nm. The assay was linear over the range 0.109-7.0 microg/mL (R(2) = 0.9999, n = 5). Mean recovery was determined as 98.39%. Intra- and inter-day precisions (RSD) were < or =7.59%. The limit of quantitation was 0.109 microg/mL. After validation, the HPLC method developed was applied to investigate the preliminary pharmacokinetics of wogonoside in rat after oral administration of Huang-Lian-Jie-Du decoction.  相似文献   

7.
A simple, fast and high-throughput LC–tandem mass spectrometry method was developed and validated to simultaneously measure liraglutide and insulin degludec in rat plasma. After protein precipitation, plasma samples were subjected to gradient elution using an InertSustain Bio C18 column with 1000/20/1 water/acetonitrile/formic acid (v/v/v) and 1000/1 acetonitrile/formic acid (v/v) as the mobile phase. The method was validated from 1.00 to 500 ng/mL of liraglutide and insulin degludec. Further, the extraction recovery from the plasma was 41.8%–49.2% for liraglutide and 56.5%–69.7% for insulin degludec. Intra- and inter-day precision of liraglutide was 3.5%–9.4% and 8.4%–9.8%, respectively, whereas its accuracy was between −12.6% and −1.3%. Intra- and inter-day precision of insulin degludec was 5.2%–13.6% and 11.8%–19.1%, respectively, showing an accuracy between −3.0% and 9.9%. As a result, the method was successfully applied to a pharmacokinetics study of liraglutide and insulin degludec following a single-dose subcutaneous administration to rats.  相似文献   

8.
Investigations have been initiated to develop a sufficiently good separation of both major and minor organic acids and inorganic anions present in grape musts using a Dionex As11 column, a sodium hydroxide gradient elution and a suppressed conductivity detection. Separation was complicated in aqueous mobile phase by co-elutions and selectivity was optimized using organic modifiers that alter ion-exchange selectivity for hydrophobic ions. In this study, the influence of three different solvents (methanol, ethanol and acetonitrile) on the efficiency of column was compared. The best separation of all ions in a synthetic solution was achieved with an eluent containing 13% (v/v) methanol and 13% (v/v) ethanol in water, the run during only 20 min. This method was next applied to grape juices with success and has shown sensitivity and reproducibility. Moreover, sample preparation was a simple 20-fold dilution with 0.45 microm filtration and direct injection without prior sample clean-up.  相似文献   

9.
Gradient elution reversed-phase high-performance liquid chromatography (RP-HPLC) was used for the determination of compounds occurring during the production of biodiesel from rapeseed oil. Individual triacylglycerols (TGs), diacylglycerols, monoacylglycerols and methyl esters of oleic, linoleic and linolenic acids and free fatty acids were separated in 25 min using a combined linear gradient with aqueous-organic and non-aqueous mobile phase steps: 70% acetonitrile+30% water in 0 min, 100% acetonitrile in 10 min, 50% acetonitrile+50% 2-propanol-hexane (5:4, v/v) in 20 min and 5 min final hold-up. Another method with a non-aqueous linear mobile phase gradient [from 100% methanol to 50% methanol+50% 2-propanol-hexane (5:4, v/v) in 15 min] was used for fast monitoring of conversion of rapeseed oil triacylglycerols to fatty acid methyl esters and for quantitation of residual TGs in the final biodiesel product. Sensitivity and linearity of various detection modes (UV detection at 205 nm, evaporative light scattering detection and mass spectrometric detection) were compared. The individual sample compounds were identified using coupled HPLC-atmospheric pressure chemical ionization mass spectrometry in the positive-ion mode.  相似文献   

10.
A major challenge in metabolomic studies is how to extract and analyze an entire metabolome. So far, no single method was able to clearly complete this task in an efficient and reproducible way. In this work we proposed a sequential strategy for the extraction and chromatographic separation of metabolites from leaves Jatropha gossypifolia using a design of experiments and partial least square model. The effect of 14 different solvents on extraction process was evaluated and an optimized separation condition on liquid chromatography was estimated considering mobile phase composition and analysis time. The initial conditions of extraction using methanol and separation in 30 min between 5 and 100% water/methanol (1:1 v/v) with 0.1% of acetic acid, 20 μL sample volume, 3.0 mL min?1 flow rate and 25°C column temperature led to 107 chromatographic peaks. After the optimization strategy using i‐propanol/chloroform (1:1 v/v) for extraction, linear gradient elution of 60 min between 5 and 100% water/(acetonitrile/methanol 68:32 v/v with 0.1% of acetic acid), 30 μL sample volume, 2.0 mL min?1 flow rate, and 30°C column temperature, we detected 140 chromatographic peaks, 30.84% more peaks compared to initial method. This is a reliable strategy using a limited number of experiments for metabolomics protocols.  相似文献   

11.
A bioanalytical method was developed for the simultaneous determination of paracetamol and ketorolac enantiomers in human plasma using two-dimensional liquid chromatography–mass spectrometry. Separation was first achieved in a reversed-phase C18 column by using a gradient solvent system consisting of 0.1% aqueous formic acid and acetonitrile (ACN). The effluent between 8.9 and 9.9 min, corresponding to phenacetin and racemic ketorolac peaks, was transferred to a polysaccharide-based chiral column (ChiralPak AD-RH) by using a six-port switching valve. Ketorolac enantiomers were subsequently separated on the chiral column using an isocratic mobile phase composed of ACN/0.1% formic acid 50:50 (v/v). The total run-time was less than 18 min. This innovative strategy prolongs the lifetime of chiral columns by avoiding damages due to the sample matrix. The detection was carried out with an ion trap mass spectrometer equipped with an electrospray ionisation source. The tested ranges were 0.05–20 μg/ml for paracetamol and 0.005–2 μg/ml for each ketorolac enantiomer. This method was fully validated and showed good performances in terms of trueness (80–110%) and precision (6.7–13.2%). The mean extraction recoveries were 60%, 72% and 76% for paracetamol, R-ketorolac and S-ketorolac, respectively. Finally, this procedure was successfully applied to a pharmacokinetic study.  相似文献   

12.
A fully automated gradient high-performance liquid chromatographic method for the determination of isotretinoin, tretinoin and their 4-oxo metabolites in plasma was developed, using the column-switching technique. After dilution with an internal standard solution containing 20% acetonitrile, 0.5 ml of the sample was injected onto a precolumn (17 X 4.6 mm I.D.), filled with C18 Corasil 37-53 micron. Proteins and polar plasma components were washed out using 1% ammonium acetate-acetonitrile (9:1, v/v) as mobile phase 1. After valve switching, the retained components were transferred to the analytical column in the backflush mode, separated by gradient elution and detected at 360 nm by UV detection. Using two coupled reversed-phase columns (125 mm long), the separation of cis and trans isomers was possible, and all four compounds could be quantified down to 2 ng/ml of plasma. The inter-assay precision in the concentration range 20-100 ng/ml was between 1.0 and 4.7% for all compounds.  相似文献   

13.
A rapid and accurate method is described for the determination of prolyl peptides in urine, with specific reference to the dipeptide prolylhydroxyproline, and free hydroxyproline and proline. Free amino acids and peptides were isolated from urine on cation-exchange minicolumns, and free imino acids and prolyl-N-terminal peptides were selectively derivatized with 4-chloro-7-nitrobenzofurazan, after reaction of amino acids and N-terminal aminoacyl peptides with o-phthalaldehyde. The highly fluorescent adducts of imino acids and prolyl peptides were separated on a Spherisorb ODS 2 column by isocratic elution for 12 min using as mobile phase 17.5 mM aqueous trifluoracetic acid solution containing 12.5% acetonitrile (eluent A), followed by gradient elution from eluent A to 40% of 17.5 mM aqueous trifluoroacetic acid solution containing 80% acetonitrile in 20 min. Analytes of interest, in particular the dipeptide prolylhydroxyproline, can be easily quantified by fluorimetric detection (epsilon ex = 470 nm, epsilon em = 530 nm) without interference from primary amino-containing compounds.  相似文献   

14.
In this work, monolithic silica columns with the C4, C8, and C18 chemistry and having various macropore diameters and two different mesopore diameters are studied to access the differences in the column efficiency under isocratic elution conditions and the resolution of selected peptide pairs under reversed-phase gradient elution conditions for the separation of peptides and proteins. The columns with the pore structural characteristics that provided the most efficient separations are then employed to optimize the conditions of a gradient separation of a model mixture of peptides and proteins based on surface chemistry, gradient time, volumetric flow rate, and acetonitrile concentration. Both the mesopore and macropore diameters of the monolithic column are decisive for the column efficiency. As the diameter of the through-pores decreases, the column efficiency increases. The large set of mesopores studied with a nominal diameter of approximately 25 nm provided the most efficient column performance. The efficiency of the monolithic silica columns increase with decreasing n-alkyl chain length in the sequence of C18相似文献   

15.
巩丽萍  石峰  宿书芳  谢强胜  咸瑞卿  杭宝建  赵艳霞 《色谱》2021,39(11):1255-1260
近年来由于驴皮资源短缺,阿胶价格大幅度上涨,市场上出现了大量以马、骡、猪、牛皮等熬制而成的假胶,导致阿胶质量的参差不齐,严重扰乱了市场,急需高效准确的检测方法提升阿胶品质。该研究采用超高效液相色谱-串联质谱技术,建立了阿胶中驴皮源成分的检测方法。样品加水溶解后,于37 ℃下经胰蛋白酶酶解,产生驴源性特征肽段,以0.1%甲酸乙腈溶液和0.1%甲酸水溶液作为流动相进行梯度洗脱,单次分析时间10 min,在电喷雾正离子(ESI+)模式下进行多反应监测(MRM),同位素内标法定量。驴源多肽A1、A2在50~1250 μg/L范围内线性关系良好,相关系数(r)均大于0.996,方法定量限(S/N=10)为20 mg/kg,在300、600、900 mg/kg 3个添加水平上驴源多肽A1、A2的回收率范围为103.2%~108.3%,各加标水平平行测定结果的相对标准偏差(RSD)为1.0%~3.0%,完全能够满足实际样品检测需求。对29批不同生产企业的阿胶进行测定,结果表明,不同企业生产的阿胶中驴源多肽A1、A2的含量之和存在差异,含量为0.096%~0.180%,平均值为0.151%,提示驴源多肽A1、A2含量较低的阿胶生产厂家应注重皮源质量,改进生产工艺,以提升产品质量。该方法操作简便,结果可靠,重现性好,可用于阿胶中驴皮源成分的测定。  相似文献   

16.
We developed a method for the simultaneous quantification of aceclofenac and its three major metabolites in rat plasma. After protein precipitation with acetonitrile including flufenamic acid as an internal standard (IS), aceclofenac, diclofenac, 4'-hydroxyaceclofenac, 4'-hydroxydiclofenac, and the IS were chromatographed on a reverse-phase C18 analytical column. The isocratic mobile phase of acetonitrile/0.1% formic acid (aq; 9:1 [v/v]) was eluted at 0.3 mL/min. Quantification was performed on a triple-quadrupole mass spectrometer using electrospray ionization, and the ion transitions were monitored in selective reaction-monitoring mode. The coefficient of variation in the assay precision was less than 8%, and the accuracy was 92-103%. This method was successfully used to measure the concentrations of aceclofenac and its three major metabolites in rat plasma following the oral administration of a single 20 mg/kg oral dose of aceclofenac.  相似文献   

17.
The aim of this study was to develop an analytical method to determine mequitazine in rat plasma and urine. Mequitazine was separated by UPLC–MS/MS equipped with a Kinetex core–shell C18 column (50 × 2.1 mm, 1.7 μm) using 0.1% (v/v) aqueous formic acid and acetonitrile containing 0.1% (v/v) formic acid as a mobile phase by gradient elution at a flow rate of 0.3 mL/min. Quantitation of this analysis was performed on a triple quadrupole mass spectrometer employing electrospray ionization technique operating in multiple reaction monitoring positive ion mode. Mass transitions were m/z 323.3 → 83.1 for mequitazine and 281.3 → 86.3 for imipramine as internal standard. Liquid–liquid extraction with ethyl acetate and protein precipitation with methanol were used for sample extraction. Chromatograms showed that the method had high resolution, sensitivity and selectivity without interference from plasma constituents. Calibration curves for mequitazine in rat plasma and urine were 0.02–200 ng/mL, showing excellent linearity with correlation coefficients (r2) >0.99. Both intra‐ and inter‐day precisions (CV%) were within 4.08% for rat plasma and urine. The accuracies were 99.58–102.03%. The developed analytical method satisfied the criteria of international guidance. It could be successfully applied to pharmacokinetic studies of mequitazine after oral and intravenous administration to rats.  相似文献   

18.
A perfusion reversed-phase HPLC method enabling the simultaneous separation of soybean and cereal (wheat, corn, and rice) proteins in commercial bakery products has been proposed for the first time. The method utilises an acetonitrile-water gradient containing an ion-pairing agent. Different ion-pairing agents were tried, 0.3% (v/v) acetic acid being observed to enable the separation of soybean from wheat, rice, and corn proteins while with 0.1% (v/v) trifluoroacetic acid only the separation of soybean and corn proteins was possible. Optimisation of the solubilisation conditions for proteins was achieved by testing different acetonitrile concentrations for the simultaneous extraction of soybean and cereal proteins: best recoveries were found with 25% (v/v) acetonitrile + 0.3% (v/v) acetic acid and with 40% (v/v) acetonitrile + 0.1% (v/v) trifluoroacetic acid. Chromatographic conditions such as gradient, temperature, and wavelength detection were also optimised. The method enabled the separation of soybean and cereal proteins in binary mixtures (soybean and wheat, soybean and corn, or soybean and rice proteins) in less than 5 minutes in a total analysis time of 20 min.  相似文献   

19.
A high‐performance liquid chromatography tandem–mass spectrometry (HPLC‐MS/MS) method has been developed to analyze anthocyanins in urine and plasma to further understand their absorption, distribution, metabolism and excretion. The method employed a Synergi RP‐Max column (250 × 4.6 mm, 4 μm) and an API 4000 mass spectrometer. A gradient elution system consisted of mobile phase A (water–1% formic acid) and mobile phase B (acetonitrile) with a flow rate of 0.60 mL/min. The gradient was initiated at 5% B, increased to 21% B at 20 min, and then increased to 40% B at 35 min. The analysis of anthocyanins presents a challenge because of the poor stability of anthocyanins during sample preparation, especially during solvent evaporation. In this method, the degradation of anthocyanins was minimized using protein precipitation and dilute‐and‐shoot and sample preparation methods for plasma and urine, respectively. No interferences were observed from endogenous compounds. The method has been used to analyze anthocyanin concentrations in urine and plasma samples from volunteers administered saskatoon berries. Cyanidin‐3‐galactoside, cyanidin‐3‐glucoside, cyanidin‐3‐arabinoside, cyanidin‐3‐xyloside and quercetin‐3‐galactoside, the five major flavonoid components in saskatoon berries, were identified in plasma and urine samples.  相似文献   

20.
张敬彩  魏杰  钟虹敏  郭志谋  张华 《色谱》2013,31(1):79-82
建立了高效液相色谱快速定量测定中药千层塔提取物中石杉碱甲含量的分析方法。千层塔提取物经甲醇/水/甲酸(10/90/0.2, v/v/v)提取并定容后,过滤膜后直接分析。色谱分离选用XCharge C18色谱柱(150 mm×4.6 mm, 5 μm),以水(含0.1%三氟乙酸)和乙腈(含0.09%三氟乙酸)为流动相进行梯度洗脱,流速为2 mL/min,于310 nm波长下检测,可在10 min内完成石杉碱甲的快速分离分析。结果表明,石杉碱甲在2.12~106 mg/L范围内线性关系良好(相关系数为0.9999);平均加标回收率为102.34%,相对标准偏差(RSD)为0.46%;日内及日间精密度均小于2%,满足定量要求。该方法简便、快速,结果可靠,重现性好,可作为千层塔提取物质量评价的依据。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号