首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
将几种香豆素类新基质(香豆素、3-羟基香豆素(3-HC)、3-氨基香豆素(3-AC)、3-羧基香豆素(3-CC)和4-甲基-7-羟基香豆素(4-M-7-HC))分别应用于基质辅助激光解吸/电离飞行时间质谱(MALDI TOF-MS)测定葡聚糖和3种糖蛋白的研究.香豆素和3-羟基香豆素分别与2,5-二羟基苯甲酸(DHB)混合组成2种二元基质,极大地改善了基质和葡聚糖样品的共结晶状况,样品分布更加均匀.葡聚糖样品更易解吸/电离,每个激光点照射样品均能产生较强的质谱信号,且谱图重现性更好,得到了理想的MALDI TOF-MS谱图.当香豆素类基质用于分析糖蛋白时:3-HC和4-M-7-HC是测定糖蛋白A的优异基质,能检测到m/z 为66 672 Da 的离子信号.而3-AC测定糖蛋白B的基质效果比糖类分析常用基质2,5-二羟基苯甲酸更好.因此,这些香豆素类化合物将为MALDI TOF-MS分析多糖和糖蛋白提供更多新基质选择.  相似文献   

2.
Matrix‐assisted laser desorption/ionization time‐of‐flight mass spectrometry (MALDI‐TOF MS) is an excellent analytical technique for rapid analysis of a variety of molecules with straightforward sample pretreatment. The performance of MALDI‐TOF MS is largely dependent on matrix type, and the development of novel MALDI matrices has aroused wide interest. Herein, we devoted to seek more robust MALDI matrix for herbal saponins than previous reported, and ginsenoside Rb1, Re, and notoginsenoside R1 were used as model saponins. At the beginning of the present study, 2,5‐dihydroxybenzoic acid (DHB) was found to provide the highest intensity for saponins in four conventional MALDI matrices, yet the heterogeneous cocrystallization of DHB with analytes made signal acquisition somewhat “hit and miss.” Then, graphene oxide (GO) was proposed as an auxiliary matrix to improve the uniformity of DHB crystallization due to its monolayer structure and good dispersion, which could result in much better shot‐to‐shot and spot‐to‐spot reproducibility of saponin analysis. The satisfactory precision further demonstrated that minute quantities of GO (0.1 μg/spot) could greatly reduce the risk of instrument contamination caused by GO detachment from the MALDI target plate under vacuum. More importantly, the sensitivity and linearity of the standard curve for saponins were improved markedly by DHB‐GO composite matrix. Finally, the application of detecting the Rb1 in complex biological sample was exploited in rat plasma and proved it applicable for pharmacokinetic study quickly. This work not only opens a new field for applications of DHB‐GO in herbal saponin analysis but also offers new ideas for the development of composite matrices to improve MALDI MS performance.  相似文献   

3.
This study demonstrates the application of 2,5-dihydrohybenzoic acid/aniline (DHB/An) and 2,5-dihydroxybenzoic acid/N,N-dimethylaniline (DHB/DMA) matrices for automated identification and quantitative analysis of native oligosaccharides by matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS). Both matrices are shown to be superior to pure DHB for native glycans in terms of signal intensities of analytes and homogeneity of sample distribution throughout the crystal layer. On-target formation of stable aniline Schiff base derivatives of glycans in DHB/An and the complete absence of such products in the mass spectra acquired in DHB/DMA matrix provide a platform for automated identification of reducing oligosaccharides in the MALDI mass spectra of complex samples. The study also shows how enhanced sensitivity is achieved with the use of these matrices and how the homogeneity of deposited sample material may be exploited for quick and accurate quantitative analysis of native glycan mixtures containing neutral and sialylated oligosaccharides in the low-nanogram to mid-picogram range.  相似文献   

4.
A large number of matrix substances have been used for various applications in matrix-assisted laser desorption/ionization mass spectrometry (MALDI MS). The majority of matrices applied in ultraviolet-MALDI MS are crystalline, low molecular weight compounds. A problem encountered with many of these matrices is the formation of hot spots, which lead to inhomogeneous samples, thus leading to increased measurement times and hampering the application of MALDI MS for quantitative purposes. Recently, ionic (liquid) matrices (ILM or IM) have been introduced as a potential alternative to the classical crystalline matrices. ILM are equimolar mixtures of conventional MALDI matrix compounds such as 2,5-dihydroxybenzoic acid (DHB), α-cyano-4-hydroxycinnamic acid (CCA) or sinapinic acid (SA) together with organic bases [e.g., pyridine (Py), tributylamine (TBA) or N,N-dimethylethylenediamine (DMED)]. The present article presents a first overview of this new class of matrices. Characteristic properties of ILM, their influence on mass spectrometric parameters such as sensitivity, resolution and adduct formation and their application in the fields of proteome analysis, the measurement of low molecular weight compounds, the use of MALDI MS for quantitative purposes and in MALDI imaging will be presented. Scopes and limitations for the application of ILM are discussed.  相似文献   

5.
MS/MS is indispensable for the amino acid sequencing of peptides. However, its use is limited for peptides containing disulfide bonds. We have applied the reducing properties of 1,5-diaminonaphthalene (1,5-DAN) as a MALDI matrix to amino acid sequencing and disulfide bond mapping of human urotensin II possessing one disulfide bond, and human guanylin possessing two disulfide bonds. 1,5-DAN was used in the same manner as the usual MALDI matrices without any pre-treatment of the peptide, and MS/MS was performed using a matrix-assisted laser desorption/ionization quadrupole ion trap time-of-flight mass spectrometer (MALDI QIT TOFMS). The results demonstrated that MS/MS of the molecular ions reduced by 1,5-DAN provided a series of significant b-/y-product ions. All 11 amino acid residues of urotensin II were identified using 1,5-DAN, while only 5 out of 11 residues were identified using 2,5-dihydroxybenzoic acid (DHB); similarly 11 out of 15 amino acid residues of guanylin were identified using 1,5-DAN, while only three were identified using DHB. In addition, comparison of the theoretical and measured values of the mass differences between corresponding MS/MS product ions using 1,5-DAN and DHB narrowed down the possible disulfide bond arrangement candidates. Consequently, 1,5-DAN as a reductive matrix facilitates rapid amino acid sequencing and disulfide mapping for peptides containing disulfide bonds.  相似文献   

6.
2,5‐Dihydroxybenzoic acid (DHB) is one of the most widely used and studied matrix compounds in matrix‐assisted laser desorption/ionization (MALDI) mass spectrometry. However, the influence of ageing of the DHB solution on the MALDI mass spectra has not been yet systematically studied. In this work, the possible changes occurring in the acidified acetonitrile/water solution of the MALDI matrix compound DHB during 1‐year usage period have been monitored with MALDI‐Fourier transform ion cyclotron resonance mass spectrometer (MALDI‐FT‐ICR‐MS) and attenuated total reflectance Fourier transform infrared (ATR‐FT‐IR) spectroscopy. No significant ageing products have been detected. The ability of the aged DHB solution to act as a MALDI matrix was tested with two materials widely used in art and conservation – bone glue (a proteinaceous material) and shellac resin (a resinous material) – and good results were obtained. A number of peaks in the mass spectra measured from the DHB solution were identified, which can be used for internal calibration of the mass axis. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

7.
For matrix‐assisted laser desorption/ionization (MALDI) mass spectra, undesirable ion contamination can occur due to the direct laser excitation of substrate materials (i.e., laser desorption/ionization (LDI)) if the samples do not completely cover the substrate surfaces. In this study, comparison is made of LDI processes on substrates of indium and silver, which easily emit their own ions upon laser irradiation, and conventional materials, stainless steel and gold. A simultaneous decrease of ion intensities with the number of laser pulses is observed as a common feature. By the application of an indium substrate to the MALDI mass spectrometry of alkali salts and alkylammonium salts mixed with matrices, 2,5‐dihydroxybenzoic acid (DHB) or N‐(4‐methoxybenzylidene)‐4‐butylaniline (MBBA), the mixing of LDI processes can be detected by the presence of indium ions in the mass spectra. This method has also been found to be useful for investigating the intrinsic properties of the MALDI matrices: DHB samples show an increase in the abundance of fragment ions of matrix molecules and cesium ions with the number of laser pulses irradiating the same sample spot; MBBA samples reveal a decrease in the level of background noise with an increase in the thickness of the sample layer. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

8.
The mass spectra of peptides obtained with different matrices were compared using a matrix-assisted laser desorption/ionization (MALDI) ion source and a multi-turn time-of-flight (TOF) mass spectrometer, MULTUM-IMG, which has been developed at Osaka University. Two types of solid matrices, alpha-cyano-4-hydroxycinnamic acid (CHCA) and 2,5-dihydroxybenzoic acid (DHB), and a liquid matrix made from a mixture of 3-aminoquinoline and CHCA were used. When measuring the peak signal intensity of human angiotensin II [M+H]+ from a fixed sample position, the liquid matrix produced a stable signal over 1000 laser shots, while the signal obtained with CHCA and DHB decayed after about 300 and 100 shots, respectively. Significant differences in the mass resolving power were not observed between the spectra obtained with the three matrices. Signal peak areas were measured as a function of the cycle number in a multi-turn ion trajectory, i.e., the total flight time over a millisecond time scale. For both [M+H]+ of human angiotensin II and bovine insulin, the decay of the signal peak area was the most significant with CHCA, while that measured with DHB was the smallest. The results of the mean initial ion velocity measurements suggested that the extent of metastable decomposition of the analyte ions increased in order of DHB, the liquid matrix, and CHCA, which is consistent with the difference in the decay of the signal peak area as the total flight time increased.  相似文献   

9.
A simple reversed-phase nano-column purification and sample preparation technique is described, which markedly improves the mass spectrometric analysis of complex and contaminated peptide mixtures by matrix-assisted laser desorption/ionization (MALDI). The method is simple, fast and utilizes only low-cost disposables. After loading the sample on the column and a subsequent washing step, the analyte molecules are eluted with 50-100 nl of matrix solution directly on to the MALDI/MS target. The washing step ensures removal of a wide range of contaminants. The small bed volume of the column allows efficient sample concentration and the elution process yields very small sample spots. This simplifies the analysis and minimizes discrimination effects due to sample heterogeneity, because the desorption/ionization laser simultaneously irradiates a large portion of the sample. Taken together, these features of the method significantly improve the sensitivity for MALDI/MS analysis of contaminated peptide samples compared with the commonly used sample preparation procedures. This is demonstrated with in-gel tryptic digests of proteins from human brain that were separated by 2D gel electrophoresis. Furthermore, it is shown that with this method 2,5-dihydroxybenzoic acid (DHB) acts as an efficient matrix for peptide mapping. Both detection sensitivity and sequence coverage are comparable to those obtained with the currently preferred matrix alpha-cyano-4-hydroxycinnamic acid (CHCA). The higher stability of peptide ions generated with DHB compared with CHCA is advantageous when analyzing fragile sample molecules. Therefore, the method described here is also of interest for the use of Fourier transform ion cyclotron resonance (FT-ICR) or ion-trap mass analyzers.  相似文献   

10.
The applicability of matrix-assisted laser desorption/ionization time of flight mass spectrometry (MALDI-TOF MS) to the analysis of wax esters (WEs) was investigated. A series of metal salts of 2,5-dihydroxybenzoic acid (DHB) was synthesized and tested as possible matrices. Alkali metal (Li, Na, K, Rb, Cs) and transition metal (Cu, Ag) salts were studied. The matrix properties were evaluated, including solubility in organic solvents, threshold laser power that should be applied for successful desorption/ionization of WEs, the nature of the matrix ions and the mass range occupied by them, and the complexity of the isotope clusters for individual metals. Lithium salt of dihydroxybenzoic acid (LiDHB) performed the best and matrices with purified lithium isotopes ((6)LiDHB or (7)LiDHB) were recommended for WEs. Three sample preparation procedures were compared: (1) mixing the sample and matrix in a glass vial and deposition of the mixture on a MALDI plate (Mix), (2) deposition of sample followed by deposition of matrix (Sa/Ma), and (3) deposition of matrix followed by deposition of sample (Ma/Sa). Morphology of the samples was studied by scanning electron microscopy. The best sample preparation technique was Ma/Sa with the optimum sample to matrix molar ratio 1 : 100. Detection limit was in the low picomolar range. The relative response of WEs decreased with their molecular weight, and minor differences between signals of saturated and monounsaturated WEs were observed. MALDI spectra of WEs showed molecular adducts with lithium [M + Li](+). Fragments observed in postsource decay (PSD) spectra were related to the acidic part of WEs [RCOOH + Li](+) and they were used for structure assignment. MALDI with LiDHB was used for several samples of natural origin, including insect and plant WEs. A good agreement with GC/MS data was achieved. Moreover, MALDI allowed higher WEs to be analyzed, up to 64 carbon atoms in Ginkgo biloba leaves extract.  相似文献   

11.
Fast and easy analysis of phospholipids (PLs) by matrix‐assisted laser desorption/ionization mass spectrometry (MALDI‐MS) has been well demonstrated. However, when using common organic matrices, such as 2,5‐dihydroxybenzoic acid (DHB), the detection of most PL classes in positive‐ion mode is difficult when PLs containing zwitterionic groups, such as phosphatidylcholines (PCs) and sphingomyelins (SMs) are present. To reduce this limitation, 2‐(2‐aminoethyloamino)‐5‐nitropyridine (AAN), a basic compound, was evaluated as an alternative matrix. Negative‐ion spectra showed enhanced detection of phosphatidyl ethanolamines (PEs), phosphatidyl serines (PSs), phosphatidyl glycerols (PGs), and phosphatidyl inositols (PIs) in simple mixtures and in a crude methanolic soybean extract. The relative ionization efficiency (RIE) was highest for PIs and lowest for PGs, PSs, and PEs. Compared to DHB and para‐nitroaniline, AAN resulted in greater sensitivity for the detection of PL classes in the negative mode. Indeed, the S/N ratio was nearly an order of magnitude higher than that reported for similar PI concentrations but with DHB. MALDI spots produced with AAN were homogeneous thus allowing automation and improved reproducibility. Positive‐mode traces could also be acquired with AAN as the matrix, but with lower sensitivity than in the negative mode. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

12.
Application of matrix‐assisted laser‐desorption/ionization mass spectrometry (MALDI MS) to analysis and characterization of phosphopeptides in peptide mixtures may have a limitation, because of the lower ionizing efficiency of phosphopeptides than nonphosphorylated peptides in MALDI MS. In this work, a binary matrix that consists of two conventional matrices of 3‐hydroxypicolinic acid (3‐HPA) and α‐cyano‐4‐hydroxycinnamic acid (CCA) was tested for phosphopeptide analysis. 3‐HPA and CCA were found to be hot matrices, and 3‐HPA not as good as CCA and 2,5‐dihydroxybenzoic acid (DHB) for peptide analysis. However, the presence of 3‐HPA in the CCA solution with a volume ratio of 1:1 could significantly enhance ion signals for phosphopeptides in both positive‐ion and negative‐ion detection modes compared with the use of pure CCA or DHB, the most common phosphopeptide matrices. Higher signal intensities of phosphopeptides could be obtained with lower laser power using the binary matrix. Neutral loss of the phosphate group (?80 Da) and phosphoric acid (?98 Da) from the phosphorylated‐residue‐containing peptide ions with the binary matrix was decreased compared with CCA alone. In addition, since the crystal shape prepared with the binary matrix was more homogeneous than that prepared with DHB, searching for ‘sweet’ spots can be avoided. The sensitivity to detect singly or doubly phosphorylated peptides in peptide mixtures was higher than that obtained with pure CCA and as good as that obtained using DHB. We also used the binary matrix to detect the in‐solution tryptic digest of the crude casein extracted from commercially available low fat milk sample, and found six phosphopeptides to match the digestion products of casein, based on mass‐to‐charge values and LIFT TOF‐TOF spectra. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

13.
A simple method was developed for rapid and direct profiling of alkaloids in medical herbs via matrix-assisted laser desorption/ionization time-of-flight mass spectrometry(MALDI-TOF MS). The dry herbs were first ground to powder and passed through a stainless steel sieve, mixed with the matrix solution to form a homogeneous suspension, which was then directly applied to MALDI analysis. Several matrices were investigated and 2,5-dihydroxybenzoic acid(DHB) was chosen as the optimized one, and the particle wit...  相似文献   

14.
Direct mass spectrometric analysis of complex biological samples is becoming an increasingly useful technique in the field of proteomics. Matrix-assisted laser desorption/ionization mass spectroscopy (MALDI-MS) is a rapid and sensitive analytical tool well suited for obtaining molecular weights of peptides and proteins from complex samples. Here, a fast and simple approach to cellular protein profiling is described in which mammalian cells are lysed directly in the MALDI matrix 2,5-dihydroxybenzoic acid (DHB) and mass analyzed using MALDI-time of flight (TOF). Using the unique MALDI mass spectral "fingerprint" generated in these analyses, it is possible to differentiate among several different mammalian cell lines. A number of techniques, including MALDI-post source decay (PSD), MALDI tandem time-of-flight (TOF-TOF), MALDI-Fourier transform ion cyclotron resonance (FTICR), and nanoflow liquid chromatography followed by electrospray ionization and tandem mass spectrometry (LC-ESI-MS/MS) were employed to attempt to identify the proteins represented in the MALDI spectra. Performing a tryptic digestion of the supernatant of the cells lysed in DHB with subsequent LC-ESI-MS/MS analysis was by far the most successful method to identify proteins.  相似文献   

15.
An experimental comparison of product ion spectra produced by matrix-assisted laser desorption/ionization (MALDI) and electrospray ion-trap MS( n) for a group of small drug molecules is presented in this paper. The goal of the study was to demonstrate the usefulness of MALDI-MS with post-source decay (PSD) and collision-induced dissociation (CID) for the structural analysis of small drug molecules in the drug discovery process, where traditionally electrospray LC/MS methods are used. PSD and PSD/CID gave diverse product ions that were highly indicative of the structure of the drugs investigated (a group of 4-quinolone antibiotics and oleandomycin). In addition, the number of different product ions generated with MALDI-MS was always higher than with electrospray ion-trap MS( n) (with n < or =4) for the drug molecules studied. This investigation also showed that the choice of a suitable MALDI matrix for the analysis of low molecular weight compounds is quite important. It was found that of the three matrices examined, alpha-cyano-4-hydroxycinnamic acid (alpha-CHCA) produced the most intense fragmentation levels while TiO2, with its advantage of virtually no low mass background signals, did not generate quite the same amount of information.  相似文献   

16.
In this work, sol–gel derived silica films were prepared for direct desorption/ionization of organic compounds in MALDI-TOF–MS analysis with the aim of improving method precision and of reducing interfering signals at low m/z values. Two commonly used MALDI matrices, 2,5-dihydroxybenzoic acid (DHB) and α-cyano-4-hydroxycinnamic acid (CHCA), were incorporated into the sol–gel network in order to absorb laser energy and to induce analyte desorption/ionization with low or absent background signals in the mass spectra. To achieve a reproducible xerogel film formation, experimental parameters for its deposition were optimized. The gel matrices were characterized by Fourier Transform Infrared (FT-IR) spectroscopy, X-ray Diffraction (XRD), and Scanning Electron Microscopy (SEM) analysis. The results proved the embedding of the matrix molecules in a disperse form into the homogeneous sol–gel material. The sol–gel matrix was then tested for the qualitative and quantitative analysis of two reference peptides, such as Bradykinin and P14R. In addition, spectral quality and method performance were assessed for quantitation of melamine, a low-molecular weight compound of food safety concern. In all cases, high quality spectra and excellent mass accuracy (between 3.5 and 13 ppm) were observed. Furthermore, the experimental results evidenced a significant improvement of the measurement repeatability on spot and between spots (relative standard deviation <10%), with respect to the traditional dried-droplet sample deposition method. Good sensitivity and linearity in the concentration range explored were obtained for peptides and melamine, demonstrating the suitability of the sol–gel-based matrix to be used for quantitative analysis.  相似文献   

17.
The behaviour of 2,5‐dihydroxybenzoic acid (2,5‐DHB) matrix under matrix‐assisted laser desorption/ionisation (MALDI) conditions was investigated, and the formation of 2,5‐DHB cluster ions, mainly dehydrated 2,5‐DHB ions, is reported. Interestingly, in the mass spectra of this compound, besides dimers and trimers, protonated tetramers, pentamers, hexamers and heptamers were also found with significant abundance. The MALDI behaviour of four flavonoids, quercetin, myricetin, luteolin and kaempferol, using 2,5‐DHB as matrix, was also investigated. The mass spectra of the flavonoids studied revealed a number of flavonoid–2,5‐DHB cluster ions (mainly with the dehydrated 2,5‐DHB). The number of clusters formed is dependent on the structure of the analyte. For luteolin and kaempferol, in particular, evidence was found for the formation of cluster ions involving retro Diels Alder fragments and intact flavonoids molecules, as well as the corresponding protonated retro Diels Alder fragments with dehydrated DHB molecules. All ion compositions were attributed taking into account high accuracy mass measurements and tandem mass spectrometry experiments. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

18.
The combination of ultrahigh-resolution mass spectrometry imaging (UHRMSI) and ultrahigh-performance liquid chromatography coupled with tandem mass spectrometry (UHPLC/MS/MS) was used for the identification and the spatial localization of atorvastatin (AT) and its metabolites in rat tissues. Ultrahigh-resolution and high mass accuracy measurements on a matrix-assisted laser desorption/ionization (MALDI)-Orbitrap mass spectrometer allowed better detection of desired analytes in the background of matrix and endogenous compounds. Tandem mass spectra were also used to confirm the identification of detected metabolites in complex matrices. The optimization of sample preparation before imaging experiments included the tissue cryogenic sectioning (thickness 20 μm), the transfer to stainless steel or glass slide, and the selection of suitable matrix and its homogenous deposition on the tissue slice. Thirteen matrices typically used for small molecule analysis, e.g., 2,5-dihydroxybenzoic acid (DHB), 1,5-diaminonaphthalene (DAN), 9-aminoacridine (AA), etc., were investigated for the studied drug and its metabolite detection efficiency in both polarity modes. Particular matrices were scored based on the strength of extracted ion current (EIC), relative ratio of AT molecular adducts, and fragment ions. The matrix deposition on the tissue for the most suitable matrices was done by sublimation to obtain the small crystal size and to avoid local variations in the ionization efficiency. UHPLC/MS profiling of drug metabolites in adjacent tissue slices with the previously optimized extraction was performed in parallel to mass spectrometry imaging (MSI) measurements to obtain more detailed information on metabolites in addition to the spatial information from MSI. The quantitation of atorvastatin in rat liver, serum, and feces was also performed.
Figure
?  相似文献   

19.
The dependence of the number of desorbed particles on laser fluence has been investigated for matrix-assisted laser desorption/ionization (MALDI) of analyte and matrix ions as well as for (photoionized) neutral matrix molecules using a homogeneous “flat-top” laser profile. Laser spot diameters ranging from 10 to 200 μm in size have been used. 2,5-Dihydroxybenzoic acid (DHB) and 3,5-dimethoxy-4-hydroxycinnamic acid (sinapic acid) have been tested as matrices. The threshold (for ion detection) is higher and the dependence of the ion signal upon higher-than-threshold fluences is stronger for directly desorbed ions than for photoionized neutral molecules. Directly desorbed analyte ions exhibit the same dependence on fluence as the matrix ions with only minor differences between the two matrices tested, so both have approximately the same detection threshold. For both ions and photoionized neutral molecules, the fluence threshold increases with decreasing spot size while the slope of the intensity/fluence curves decreases. A quasi-thermal, sublimation/desportion model was found to describe the experimental results with excellent precision. For a complete explanation, non-equilibrium effects had to be taken into account.  相似文献   

20.
In our laboratory, we have been studying the reductive processes that occur during matrix-assisted laser desorption/ionization (MALDI) experiments. Recently, we have finished an analysis of the DHB matrix effect on the azo group in cyclic peptides. However, deep understanding of disulfide bond behaviour during a mass spectrometry (MS) experiment is much more important in proteomics as its reduction can cause serious errors in protein spectra interpretation. Therefore, we have focused on intra- and intermolecular disulfide bonds as well as disulfide bonds connecting cysteine and 2-thio-5-nitrobenzoic acid (TNB, Ellman's reagent modification) in model peptides during MALDI MS measurements. While the reduction was not observed for intra- and intermolecular cysteine-cysteine disulfide bonds, the disulfide connection between cysteine and TNB was always affected. It was proved that TNB and Ellman's reagent can act as a matrix itself. The results obtained enabled us to propose a reaction mechanism model which is able to describe the phenomena observed during the desorption/ionization process of disulfide-containing molecules.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号