首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
In this paper, we proposed a wavelength selection method based on random decision particle swarm optimization with attractor for near‐infrared (NIR) spectra quantitative analysis. The proposed method was incorporated with partial least square (PLS) to construct a prediction model. The proposed method chooses the current own optimal or the current global optimal to calculate the attractor. Then the particle updates its flight velocity by the attractor, and the particle state is updated by the random decision with the new velocity. Moreover, the root‐mean‐square error of cross‐validation is adopted as the fitness function for the proposed method. In order to demonstrate the usefulness of the proposed method, PLS with all wavelengths, uninformative variable elimination by PLS, elastic net, genetic algorithm combined with PLS, the discrete particle swarm optimization combined with PLS, the modified particle swarm optimization combined with PLS, the neighboring particle swarm optimization combined with PLS, and the proposed method are used for building the components quantitative analysis models of NIR spectral datasets, and the effectiveness of these models is compared. Two application studies are presented, which involve NIR data obtained from an experiment of meat content determination using NIR and a combustion procedure. Results verify that the proposed method has higher predictive ability for NIR spectral data and the number of selected wavelengths is less. The proposed method has faster convergence speed and could overcome the premature convergence problem. Furthermore, although improving the prediction precision may sacrifice the model complexity under a certain extent, the proposed method is overfitted slightly. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

2.
A novel near infrared (NIR) modeling method—Laplacian regularized least squares regression (LapRLSR) was presented, which can take the advantage of many unlabeled spectra to promote the prediction performance of the model even if there are only few calibration samples. Using LapRLSR modeling, NIR spectral analysis was applied to the online monitoring of the concentration of salvia acid B in the column separation of Salvianolate. The results demonstrated that LapRLSR outperformed partial least squares (PLS) significantly, and NIR online analysis was applicable.  相似文献   

3.
This paper proposes an analytical method for simultaneous near-infrared (NIR) spectrometric determination of α-linolenic and linoleic acid in eight types of edible vegetable oils and their blending. For this purpose, a combination of spectral wavelength selection by wavelet transform (WT) and elimination of uninformative variables (UVE) was proposed to obtain simple partial least square (PLS) models based on a small subset of wavelengths. WT was firstly utilized to compress full NIR spectra which contain 1413 redundant variables, and 42 wavelet approximate coefficients were obtained. UVE was then carried out to further select the informative variables. Finally, 27 and 19 wavelet approximate coefficients were selected by UVE for α-linolenic and linoleic acid, respectively. The selected variables were used as inputs of PLS model. Due to original spectra were compressed, and irrelevant variables were eliminated, more parsimonious and efficient model based on WT-UVE was obtained compared with the conventional PLS model with full spectra data. The coefficient of determination (r2) and root mean square error prediction set (RMSEP) for prediction set were 0.9345 and 0.0123 for α-linolenic acid prediction by WT-UVE-PLS model. The r2 and RMSEP were 0.9054, 0.0437 for linoleic acid prediction. The good performance showed a potential application using WT-UVE to select NIR effective variables. WT-UVE can both speed up the calculation and improve the predicted results. The results indicated that it was feasible to fast determine α-linolenic acid and linoleic acid content in edible oils using NIR spectroscopy.  相似文献   

4.
Sample selection is often used to improve the cost-effectiveness of near-infrared (NIR) spectral analysis. When raw NIR spectra are used, however, it is not easy to select appropriate samples, because of background interference and noise. In this paper, a novel adaptive strategy based on selection of representative NIR spectra in the continuous wavelet transform (CWT) domain is described. After pretreatment with the CWT, an extension of the Kennard–Stone (EKS) algorithm was used to adaptively select the most representative NIR spectra, which were then submitted to expensive chemical measurement and multivariate calibration. With the samples selected, a PLS model was finally built for prediction. It is of great interest to find that selection of representative samples in the CWT domain, rather than raw spectra, not only effectively eliminates background interference and noise but also further reduces the number of samples required for a good calibration, resulting in a high-quality regression model that is similar to the model obtained by use of all the samples. The results indicate that the proposed method can effectively enhance the cost-effectiveness of NIR spectral analysis. The strategy proposed here can also be applied to different analytical data for multivariate calibration.  相似文献   

5.
An algorithm is proposed for extracting relevant information from near-infrared (NIR) spectra for multivariate calibration of routine components in complex plant samples. The algorithm is a combination of wavelet transform (WT) data compression and a procedure for uninformative variable elimination (UVE). After compression of the NIR spectra by WT, the UVE approach is used to eliminate the irrelevant wavelet coefficients. Finally, a calibration model is built from the retained wavelet coefficients to enable prediction. Because irrelevant information can be removed from the spectra used for multivariate calibration, the model based on the extracted relevant features is better than those obtained with full-spectrum data. Both prediction precision and calculation speed are improved.  相似文献   

6.
Hydroxyl (OH) number of polyol was measured using near-infrared (NIR) spectroscopy with the use of a disposable glass vial as a sample container. Polyols are viscous, so disposable vials are advantageous when spectroscopic methods are employed. Due to the curvature of the vial walls, a narrow aperture was used to minimize the spectroscopic deviations. The narrow aperture attenuated the NIR radiation and increased the spectral noise in the collected polyol spectra. Wavelet transformation (WT) was employed to reduce this noise and partial least squares (PLS) calibration model was developed. The overall prediction results compare well with those from conventional wet analysis that requires time (1–3 h) and large amounts of chemical reagents. NIR spectroscopy with the use of disposable vials can be utilized for a simple and fast quality assurance of polyol in actual industrial settings.  相似文献   

7.
This paper indicates the possibility to use near infrared (NIR) spectroscopy as a rapid method to predict quantitatively the content of caffeine and total polyphenols in green tea. A partial least squares (PLS) algorithm is used to perform the calibration. To decide upon the number of PLS factors included in the PLS model, the model is chosen according to the lowest root mean square error of cross-validation (RMSECV) in training. The correlation coefficient R between the NIR predicted and the reference results for the test set is used as an evaluation parameter for the models. The result showed that the correlation coefficients of the prediction models were R = 0.9688 for the caffeine and R = 0.9299 for total polyphenols. The study demonstrates that NIR spectroscopy technology with multivariate calibration analysis can be successfully applied as a rapid method to determine the valid ingredients of tea to control industrial processes.  相似文献   

8.
Partial least squares(PLS),back-propagation neural network(BPNN)and radial basis function neural network(RBFNN)were respectively used for estalishing quantative analysis models with near infrared(NIR)diffuse reflectance spectra for determining the contents of rifampincin(RMP),isoniazid(INH)and pyrazinamide(PZA)in rifampicin isoniazid and pyrazinamide tablets.Savitzky-Golay smoothing,first derivative,second derivative,fast Fourier transform(FFT)and standard normal variate(SNV)transformation methods were applied to pretreating raw NIR diffuse reflectance spectra.The raw and pretreated spectra were divided into several regions,depending on the average spectrum and RSD spectrum.Principal component analysis(PCA)method was used for analyzing the raw and pretreated spectra in different regions in order to reduce the dimensions of input data.The optimum spectral regions and the models' parameters were chosen by comparing the root mean square error of cross-validation(RMSECV)values which were obtained by leave-one-out cross-validation method.The RMSECV values of the RBFNN models for determining the contents of RMP,INH and PZA were 0.00288,0.00226 and 0.00341,respectively.Using these models for predicting the contents of INH,RMP and PZA in prediction set,the RMSEP values were 0.00266,0.00227 and 0.00411,respectively.These results are better than those obtained from PLS models and BPNN models.With additional advantages of fast calculation speed and less dependence on the initial conditions,RBFNN is a suitable tool to model complex systems.  相似文献   

9.
In order to increase the predictive ability of the PLS (Partial Least Squares) model, we have developed a new algorithm, by which uninformative samples which cannot contribute to the model very much are eliminated from a calibration data set. In the proposed algorithm, uninformative wavelength (or independent) variables are eliminated at the first stage by using the modified UVE (Uninformative Variable Elimination)-PLS method that we reported previously. Then, if the prediction error of the ith (1 < or =i< or = n) sample is larger than 3sigma, the corresponding sample is eliminated as uninformative, where n is the total number of calibration samples and sigma is the standard deviation calculated from the other n(-1) samples. Calculation of sigma by the leave-one-out manner enhances the ability to identify the uninformative samples. The final PLS model is constructed precisely because both uninformative wavelength variables and uninformative samples are eliminated. In order to demonstrate the usefulness of the algorithm, we have applied it to two kinds of mid-infrared spectral data sets.  相似文献   

10.
This study proposes an analytical method for the simultaneous near infrared (NIR) spectrometric determination of palmitic, oleic, linoleic and linolenic acids in sea buckthorn seed oil. For this purpose, four different combinations of multivariate calibration methods and variable selections were evaluated: partial least squares (PLS) with full spectrum; PLS with uninformative variables elimination (UVE); PLS with competitive adaptive reweighted sampling (CARS); and multiple linear regression (MLR) with uninformative variable elimination combined with successive projections algorithm (UVE-SPA). An independent set of samples was employed to evaluate the performance of the resulting models. The UVE-SPA-MLR model developed with a few spectral variables provided the best results for each parameter. The values of relative errors of prediction (REP) from the UVE-SPA-MLR model for palmitic, oleic, linoleic and linolenic acids are 1.77%, 1.20%, 1.02% and 1.40%, respectively. These results indicate that this method is a feasible and fast method for the determination of the fatty acid content of sea buckthorn seed oil.  相似文献   

11.
A new hybrid algorithm is proposed for construction of a high-quality calibration model for near-infrared (NIR) spectra that is robust against both spectral interference (including background and noise) and multiple outliers. The algorithm is a combination of continuous wavelet transform (CWT) and a modified iterative reweighted PLS (mIRPLS) procedure. In the proposed algorithm the spectral interference is filtered by CWT at the first stage then mIRPLS is proposed to detect the multiple outliers in the CWT domain. Compared with the original IRPLS method, mIRPLS does not need to adjust variable parameters to achieve optimum calibration results, which makes it very convenient to perform in practice. The final PLS model is constructed robustly because both the spectral interference and multiple outliers are eliminated. In order to validate the effectiveness and universality of the algorithm, it was applied to two different sets of NIR spectra. The results indicate that the proposed strategy can greatly enhance the robustness and predictive ability of NIR spectral analysis.  相似文献   

12.
A new method for the prediction of the drug release profiles during a running pellet coating process from in-line near infrared (NIR) measurements has been developed. The NIR spectra were acquired during a manufacturing process through an immersion probe. These spectra reflect the coating thickness that is inherently connected with the drug release. Pellets sampled at nine process time points from thirteen designed laboratory-scale coating batches were subjected to the dissolution testing. In the case of the pH-sensitive Acryl-EZE coating the drug release kinetics for the acidic medium has a sigmoid form with a pronounced induction period that tends to grow along with the coating thickness. In this work the autocatalytic model adopted from the chemical kinetics has been successfully applied to describe the drug release. A generalized interpretation of the kinetic constants in terms of the process and product parameters has been suggested. A combination of the kinetic model with the multivariate Partial Least Squares (PLS) regression enabled prediction of the release profiles from the process NIR data. The method can be used to monitor the final pellet quality in the course of a coating process.  相似文献   

13.
基于群体智能的灰狼优化(GWO)算法具有参数少、结构简单、易于实现的优点,但在光谱领域的应用较少。该研究将GWO算法引入近红外光谱的变量筛选中,以玉米数据为例,考察了GWO算法中狼群性能、迭代次数、狼群数量及运算效率,并建立了偏最小二乘(PLS)模型对玉米样品中蛋白质、脂肪、水分以及淀粉含量的测定。结果显示,GWO算法运算效率很高,经过参数调优后建立PLS模型,其蛋白质、脂肪、水分及淀粉的保留变量数分别为19、19、14、34,预测均方根误差(RMSEP)从全波长PLS建模的0.245 8、0.122 4、0.339 8、1.105 8分别下降到0.147 7、0.080 1、0.176 2、0.739 8,分别下降了40%、35%、48%、33%,相关系数也相应地提高。因此,GWO算法不仅优化速度快,选择变量数少,还可以显著提高PLS模型的预测精度,是一种近红外光谱变量选择的有效方法。  相似文献   

14.
A new cut-off criterion has been proposed for the selection of uninformative variables prior to chemometric partial least squares (PLS) modelling. After variable elimination, PLS regressions were made and assessed comparing the results with those obtained by PLS models based on the full spectral range. To assess the prediction capabilities, uninformative variable elimination (UVE)-PLS and PLS were applied to diffuse reflectance near-infrared spectra of heroin samples. The application of the proposed new cut-off criterion, based on the t-Students distribution, provided similar predictive capabilities of the PLS models than those obtained using the original criteria based on quantile value. However, the repeatability of the number of selected variables was improved significantly.  相似文献   

15.
This study compares the performance of partial least squares (PLS) regression analysis and artificial neural networks (ANN) for the prediction of total anthocyanin concentration in red-grape homogenates from their visible-near-infrared (Vis-NIR) spectra. The PLS prediction of anthocyanin concentrations for new-season samples from Vis-NIR spectra was characterised by regression non-linearity and prediction bias. In practice, this usually requires the inclusion of some samples from the new vintage to improve the prediction. The use of WinISI LOCAL partly alleviated these problems but still resulted in increased error at high and low extremes of the anthocyanin concentration range. Artificial neural networks regression was investigated as an alternative method to PLS, due to the inherent advantages of ANN for modelling non-linear systems. The method proposed here combines the advantages of the data reduction capabilities of PLS regression with the non-linear modelling capabilities of ANN. With the use of PLS scores as inputs for ANN regression, the model was shown to be quicker and easier to train than using raw full-spectrum data. The ANN calibration for prediction of new vintage grape data, using PLS scores as inputs, was more linear and accurate than global and LOCAL PLS models and appears to reduce the need for refreshing the calibration with new-season samples. ANN with PLS scores required fewer inputs and was less prone to overfitting than using PCA scores. A variation of the ANN method, using carefully selected spectral frequencies as inputs, resulted in prediction accuracy comparable to those using PLS scores but, as for PCA inputs, was also prone to overfitting with redundant wavelengths.  相似文献   

16.
独立分量分析预处理法提高苹果糖度模型预测精度研究   总被引:1,自引:0,他引:1  
邹小波  赵杰文 《分析化学》2006,34(9):1291-1294
为了提高苹果近红外光谱糖度预测模型精度,利用独立分量分析方法(ICA)对苹果近红外光谱进行了预处理,并且建立了糖度的偏最小二乘(PLS)预测模型。结果表明,独立分量分析不但能分离出噪声信号,而且所分离出来的光谱信号也比原始光谱信号光滑。在预处理后的最佳PLS糖度模型校正时的相关系数rc和标准偏差SEC分别为0.9549和0.3361,用于预测时的相关系数rp和标准偏差SEP分别为0.9071和0.4355。与普通的平均处理法的PLS模型相比,其精度有所提高,且模型更加简洁。  相似文献   

17.
Near infrared (NIR) reflectance and Raman spectrometry were compared for determination of the oil and water content of olive pomace, a by-product in olive oil production. To enable comparison of the spectral techniques the same sample sets were used for calibration (1.74–3.93% oil, 48.3–67.0% water) and for validation (1.77–3.74% oil, 50.0–64.5% water). Several partial least squares (PLS) regression models were optimized by cross-validation with cancellation groups, including different spectral pretreatments for each technique. Best models were achieved with first-derivative spectra for both oil and water content. Prediction results for an independent validation set were similar for both techniques. The values of root mean square error of prediction (RMSEP) were 0.19 and 0.20–0.21 for oil content and 2.0 and 1.8 for water content, using Raman and NIR, respectively. The possibility of improving these results by combining the information of both techniques was also tested. The best models constructed using the appended spectra resulted in slightly better performance for oil content (RMSEP 0.17) but no improvement for water content.  相似文献   

18.
Wu D  He Y  Feng S 《Analytica chimica acta》2008,610(2):232-242
In this study, short-wave near-infrared (NIR) spectroscopy at 800–1050 nm region was investigated for the analysis of main compounds in milk powder. Through quantitative analysis, the feasibility is further demonstrated for the simultaneous measurement of fat, proteins and carbohydrate in milk powder. Two models, partial least-squares and least-squares support vector machine, were compared and utilized for regression coefficients and loading weights. The affect of standard normal variate spectral pretreatment to model performance was evaluated. Based on the resulted coefficients and loading weights, interesting wavelength regions of nutrition in milk powder are screened and the assignment of all specific wavelengths is firstly proposed in the details associated with chemical base. Instead of the whole short-wave NIR spectral data, these assigned wavelengths which can be reliably exploited were used for the content determination. Compared with other spectroscopy technique, assigned short-wave NIR spectral wavelengths did a good work. Determination coefficients for prediction are 0.981, 0.984, and 0.982, respectively for three components. The proposed wavelength assignment in the short-wave NIR region could be used for the component contents determination of milk powder, and could be as a guidance to interpret the spectra of milk powder.  相似文献   

19.
A new class-modeling method, referred to as partial least squares density modeling (PLS-DM), is presented. The method is based on partial least squares (PLS), using a distance-based sample density measurement as the response variable. Potential function probability density is subsequently calculated on PLS scores and used, jointly with residual Q statistics, to develop efficient class models. The influence of adjustable model parameters on the resulting performances has been critically studied by means of cross-validation and application of the Pareto optimality criterion. The method has been applied to verify the authenticity of olives in brine from cultivar Taggiasca, based on near-infrared (NIR) spectra recorded on homogenized solid samples. Two independent test sets were used for model validation. The final optimal model was characterized by high efficiency and equilibrate balance between sensitivity and specificity values, if compared with those obtained by application of well-established class-modeling methods, such as soft independent modeling of class analogy (SIMCA) and unequal dispersed classes (UNEQ).  相似文献   

20.
应用近红外光谱(NIRS)技术结合偏最小二乘(PLS)和最小二乘支持向量机(LS-SVM)建立了附子中多指标成分的快速无损检测方法.选取38批样品建立了同时测定附子样品中6种成分含量的高效液相色谱(HPLC)方法;通过采集附子样品的NIRS图,分别采用PLS和LS-SVM建立了各个成分HPLC测定值与NIRS图的定量校...  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号