共查询到20条相似文献,搜索用时 15 毫秒
1.
An experimental investigation has been carried out to study the enhancement in heat transfer coefficient by inserting coiled wire around the outer surface of the inner tube of the double-pipe heat exchanger. Insulated wires, with a circular cross-section of 2 mm diameter, forming a coil of different pitches (p = 6, 12, and 20 mm), were used as turbulators. The investigation is performed for turbulent water flow in a double-pipe heat exchanger with cold water in the annulus space for both parallel and counter flows. The experiments were performed for Reynolds numbers ranging from 4,000 to 14,000. The experimental results reveal that the use of coiled circular wires leads to a considerable increase in heat transfer coefficients compared with a smooth wall tube for both parallel and counter water flows. The mean Nusselt number increases with Reynolds number and pitch. The convective heat transfer coefficient for a turbulent water flow increases for all coiled wire pitches, with the highest enhancement of about 450% for counter flow and 400% for the parallel flow. New correlations for mean relative Nusselt numbers at different coiled wire pitches are provided. 相似文献
2.
Forced convection heat transfer from a helically coiled heat exchanger embedded in a packed bed of spherical glass particles was investigated experimentally. With dry air at ambient pressure and temperature as a flowing fluid, the effect of particle size, helically coiled heat exchanger diameter, and position was studied for a wide range of Reynolds numbers. It was found that the particle diameter, the helically coiled heat exchanger diameter and position, and the air velocity are of great influence on the convective heat transfer between the helically coiled heat exchanger and air. Results indicated that the heat transfer coefficient increased with increasing the air velocity, increasing helically coiled heat exchanger diameter, and decreasing the particle size. The highest heat transfer coefficients were obtained with the packed-bed particle size of 16 mm and heat exchanger coil diameter of 9.525 mm (1/4 inch) at a Reynolds number range of 1,536 to 4,134 for all used coil positions in the conducted tests. A dimensionless correlation was proposed for Nusselt number as a function of Reynolds number, particle size, coil size, and coil position. 相似文献
3.
Air bubble injection was employed to increase the heat transfer rate (Nusselt number) of a vertical shell and coiled tube heat exchanger in this article. Hot and cold water flowed into the coil side and shell side of heat exchanger, respectively, and air bubbles were injected inside the shell side of heat exchanger via a memorable method. Bubbles' vertical movement due to buoyancy forcing through the heat exchanger can enhance the heat transfer rate by mixing the thermal boundary layer, increasing the turbulence level of the fluid flow and increasing the shell-side fluid Reynolds number. 相似文献
4.
工业烟气含尘的特点易导致换热器积灰,进而制约烟气余热的高效回收。本文针对一种具有超大拓展表面的三维微肋管换热器的对流换热与积灰特性进行了研究。首先,对比研究了光管与三维微肋管的对流换热特性;接着,基于所建立的积灰数值模型,探究了三维微肋管的积灰特性,并揭示了烟气流速与飞灰粒径对其积灰特性的影响规律。结果表明,相对于传统光管,三维微肋管的换热面积可增大约2.9倍;换热性能平均能提高16%;积灰后渐进污垢热阻最大能减小70%;同时,清灰周期更长,运行经济性更佳。综合而言,三维微肋管相比传统光管,在增强换热的同时,还能有效减轻积灰,因此可作为高效的抗积灰传热元件,应用于含尘烟气的余热回收场合。 相似文献
5.
《Heat Recovery Systems and CHP》1989,9(3):249-256
Experiments have been conducted, and correlations are developed for the pressure drop and heat transfer coefficient for the tube and shell sides of a helical coil heat exchanger. In the tube side, the laminar friction factor and Nusselt numbers are represented as functions of Re√d/D, whereas in turbulent flow the results are correlated with Re·(d/D)2. The pressure drop and heat transfer values for the shell side are found to follow the classical Blasius and Dittus-Boelter type relations, while a strong dependence on the coil to tube diameter ratio is detected. The performance of the exchanger has been tested not only as simulated experimental exchanger but also as a waste heat recovery device for a 60 HP gas turbine. Excellent corroboration of the effectiveness-NTU relation has been observed between the simulation and in situ experiments. 相似文献
6.
7.
8.
9.
Enhancement of heat transfer in a heat exchanger via a DC corona discharge was studied experimentally using a single-tube shell-and-tube heat exchanger. Air was the working fluid in both the tube and shell sides. Excitation of the tube side was via a single wire electrode, while that of the shell side was via four rod electrodes oriented symmetrically at 90° intervals. Three series of experiments were performed: (1) excitation of the tube side only, (2) excitation of the shell side only, and (3) simultaneous excitation of the tube and shell sides. Both heat transfer and pressure drop measurements were performed, with Reynolds number and electric field potential as parametric quantities in the tube and shell sides. It was found that highest enhancements take place when the tube and shell sides are excited simultaneously, yielding a 322% increase in the overall heat transfer coefficient. Study of the heat transfer enhancements per unit pumping power indicates that for the range of parameters studied, the technique is most efficient at moderate Reynolds numbers and at electrode potentials in the midrange between threshold and sparkover limits. 相似文献
10.
波纹板式空冷器阻力与传热特性实验研究 总被引:5,自引:0,他引:5
在可改变风量和热水流量的实验条件下,对波纹板式空冷器的阻力与传热特性进行实验研究。得到了空气侧的阻力降关联式以及两侧的对流换热系数关联式,其适用于热水雷诺数在2000-8000之间、空气雷诺数在2000-10000之间。在相同工况下,比较了波纹板式、光管式和翅片管式空冷器的性能指标,结果表明:迎面风速在2.45-4.1 m/s之间,波纹板式空冷器传热系数达到100-160 W/m2/℃;约比光管式提高70%,但只有以管束外表面为基准的翅片管式传热系数的六分之一;板式空冷器单位体积换热量约是翅片管式空冷器的1.5倍,是光管式的15倍;板式空冷器单位功耗换热量约是光管式空冷器的5.5倍,而翅片管式空冷器与光管式空冷器则相差不大。 相似文献
11.
12.
Cooling technology is facing new challenges with the increase of electronic equipment power onboard aircraft. The traditional heat sink based on high-altitude bleed air does not satisfy this increase of cooling demands. In this article, an air/air-type skin heat exchanger is studied for cooling aircraft electronic equipment. It uses outside high-altitude cold air rather than bleed air as a heat sink. This cooling technology can effectively remove the heat load of high-power electronic devices without greatly increasing aircraft performance penalty. To assess its high-altitude heat transfer performance, an experimental prototype was designed and made. Some experiments were conducted on a ground experimental test. The heat transfer criteria formulas were obtained for both the side air in the skin heat exchanger and its convective heat transfer coefficients. Based on these experimental analyses, the heat transfer performances of the skin heat exchanger in a high-altitude cruise condition are deduced when it is assumed to be installed at an unfavorable position and a favorable position, separately. This work tries to provide a technical support for its future onboard application. 相似文献
13.
14.
Efficient and economical utilization of industrial waste heat would result in reduced energy use and thereby contribute to reduction of greenhouse gas emissions to the atmosphere. Two-phase thermosyphon technology has demonstrated the potential capability for waste heat recovery, but it has not been yet utilized in large-scale industrial applications. As a part of an industrial project, various types of thermosyphon heat pipes have been designed and tested for extraction of waste heat and process control in aluminum industry. This article presents the heat and mass transfer model, developed to provide a fast and accurate simulation tool for industrial application of thermosyphon heat pipe technology for waste heat utilization. The mathematical model considers the energy, momentum, and mass transfer equations, in their one-dimensional form, to predict output parameters of the thermosyphon and enable parametric and sensitivity analysis. The mathematical model structure is set up in a way that the least numerical cost and time is spent while the model accuracy is kept at acceptable level for the defined application. To provide experimental data for validation of the simulation model, the proposed thermosyphon was tested experimentally using a test set-up instrumented for this purpose. The simulation results are found to be in good agreement with the experimental data. The developed model and code are viable to be used as a simple and fast tool for modeling, design, and optimization of the thermosyphon as an element in a heat recovery module. 相似文献
15.
16.
对倾斜角为20°、24°、28°和32°的单头以及32°的双头周向重叠三分螺旋折流板换热器和弓形折流板换热器的传热和压降性能进行了测试,换热器采用公共壳体和可更换管芯结构。采用壳侧轴向雷诺数和轴向欧拉数分别作为反映壳侧流量和阻力系数的无因次参数。试验结果显示在试验范围内周向重叠三分螺旋折流板换热器壳侧换热系数、壳侧压降和综合性能指标都随着倾斜角增大而减小;倾斜角20°方案的性能指标最佳,其平均壳侧努塞尔数和轴向欧拉数与弓形折流板方案的数值之比分别为1.123和0.45;双头螺旋折流板方案的换热系数和压降都大于同样倾斜角的单头螺旋折流板方案,但两者的综合性能较接近。 相似文献
17.
采用实验的方法,研究了在较宽的不凝气体含量范围内,煤油蒸汽在不同几何结构的螺旋扁管管束外的冷凝换热现象,得出了螺旋扁管的几何结构对冷凝换热的影响规律,并与同样条件下的光管管束的冷凝换热进行了分析比较。 相似文献
18.
螺旋折流片强化壳侧传热的四管模型数值模拟 总被引:2,自引:0,他引:2
针对螺旋折流片管壳式换热器的正方形布管方式,建立了相间套螺旋折流片的四管数学物理模型,利用FLUENT软件对该模型的流动与传热情况进行了数值模拟;并与光滑通道中及单管螺旋折流片模型的流动和传热结果进行了对比.结果显示旋向相反的相邻螺旋折流片所诱导的两股旋流通过相互作用可提高通道内流体流速,并有效地形成对相邻传热管外的斜向冲刷,这对于减薄边界层,促进近壁流体与主流区流体的动量和质量交换进而强化传热有明显的作用,算例显示其传热系数可比相同尺寸的光管通道中的情形提高约44%~57%. 相似文献
19.
Organic Rankine Cycle (ORC) is an effective way to recycle waste heat sources of a marine diesel engine. The aim of the present paper is to analyze and optimize the thermoeconomic performance of a Series Heat Exchangers ORC (SHEORC) for recovering energy from jacket water, scavenge air, and exhaust gas. The three sources are combined into three groups of jacket water (JW)→exhaust gas (EG), scavenge air (SA)→exhaust gas, and jacket water→scavenge air→exhaust gas. The influence of fluid mass flow rate, evaporation pressure, and heat source recovery proportion on the thermal performance and economic performance of SHEORC was studied. A single-objective optimization with power output as the objective and multi-objective optimization with exergy efficiency and levelized cost of energy (LCOE) as the objectives are carried out. The analysis results show that in jacket water→exhaust gas and jacket water→scavenge air→exhaust gas source combination, there is an optimal heat recovery proportion through which the SHEORC could obtain the best performance. The optimization results showed that R245ca has the best performance in thermoeconomic performance in all three source combinations. With scavenge air→exhaust, the power output, exergy efficiency, and LCOE are 354.19 kW, 59.02%, and 0.1150 $/kWh, respectively. Integrating the jacket water into the SA→EG group would not increase the power output, but would decrease the LCOE. 相似文献
20.
简述了列管式换热器强化传热技术的进展及发展方向,管程强化传热采用螺纹管、横纹管、波纹管、缩放管、管内插入物、三维内肋管、翘片管等传热元件,壳程强化传热采用板式支撑、折流插式支撑、空心环支撑、管子自支撑等管束支撑结构。指出了列管式换热器研究中存在的不足。指出了今后的发展方向,为列管式换热器的研究和应用提供理论参考。 相似文献