首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A method is described for the determination of 16 sulfonamides in honey. Samples are dissolved in phosphoric acid solution (pH2), cleaned up with 2 solid-phase extraction (SPE) cartridges, an aromatic sulfonic cation-exchange cartridge and an Oasis HLB SPE cartridge, and analyzed both qualitatively and quantitatively by liquid chromatography/tandem mass spectrometry (LC/MS/MS) under the selected conditions. Without exception, calibration curves were linear (r = > 0.995), when sulfamethizole was between 1.0 and 25.0 microg/kg; sulfacetamide, sulfapyridine, sulfadiazine, sulfachloropyridazine, sulfamethoxazole, sulfamerazine, sulfisoxazole, sulfamonomethoxine, and sulfadoxine were between 2.0 and 50.0 microg/kg; sulfamethoxypyridazine, sulfadimethoxine, and sulfathiazole were between 4.0 and 100.0 microg/kg; sulfamethazine and sulfameter were between 8.0 and 200.0 microg/kg; and sulfaphenazole was between 12.0 and 300.0 microg/kg. Average recoveries at 4 fortification levels in the range of 1.0-300 microg/kg in honey were 70.9-102.5%, and relative standard deviations were 2.02-11.52%. The limits of quantitation for the 16 sulfonamides were between 1.0 and 12.0 microg/kg, with the LC/MS/MS method.  相似文献   

2.
The present work describes the development and optimization of a capillary (zone) electrophoresis/mass spectrometric (CE/MS) analysis method for polar hydrophilic aromatic sulfonates (ASs). The compounds were detected by negative ion electrospray ionization (NIESI) and selected ion monitoring (SIM). In comparison with CE/UV, for CE/MS a lower-concentration volatile ammonium acetate buffer (5 mM) without organic modifier and a higher separation voltage were better suited for separation. Sensitivity of CE/MS was slightly better than for CF/UV, with the limit of detection (LOD) ranging between 0.1 and 0.4 mg l(-1). For verification of the CE/MS results, ASs were also analysed by ion-pair liquid chromatography/diode array UV detection coupled in series with electrospray mass spectrometry (IPC/DAD/ESI-MS). Real water samples of different waste water treatment plants (WWTPs) in Catalonia (NE Spain) were extracted by solid-phase extraction (SPE) with LiChrolut EN and analysed with CE/MS and LC/MS. ASs were found in influent and effluent water samples of the WWTPs in the microg l(-1) concentration range. LC/MS offered a higher separation efficiency and sensitivity than CE/MS. Therefore with LC/MS more compounds could be identified in the WWTPs. The persistency of the ASs was distinct: some compounds were well degraded during the water treatment process, while others were quite persistent.  相似文献   

3.
A simple liquid chromatography/mass spectrometry (LC/MS) approach for the determination of widely used representatives of polar/thermolabile pesticides in fruits was developed and validated. The group of pesticides comprised benzimidazoles and azoles (carbendazim, thiabendazole, imazalil, propiconazole, prochloraz, epoxiconazole, flusilazole, tebuconazole, bitertanol); N-methylcarbamates (carbaryl, carbofuran, methiocarb); and phenylureas and benzoylphenylureas (linuron, diflubenzuron, triflumuron, teflubenzuron, flufenoxuron). Matrixes (apple, apricot) were extracted with acetonitrile and crude extracts were cleaned up by solid-phase extraction (SPE) using either mixed cation exchange or hydrophilic lipophilic balance cartridges. LC separation of pesticides was performed on a reversed-phase column, Discovery C18. Electrospray ionization and ion trap MS/MS detection were applied. For most pesticides, overall recoveries ranged from 75 to 122%, and repeatability (as relative standard deviation) from 5 repetitive determinations of recovery ranged from 3 to 21%. Carbofuran was the only compound for which recovery was not satisfactory due to its loss in the SPE cleanup step. Limits of detection were 0.1-3 microg/kg for benzimidazole and azole fungicides and carbamate insecticides. For urea insecticides, detection limits were slightly higher (3-10 microg/kg).  相似文献   

4.
This paper presents an analytical method for the determination of quinolones in chicken tissues. The procedure involves pre-treatment by solid-phase extraction (SPE) and subsequent liquid chromatography (LC) with UV absorbance detection. Different SPE disposable cartridges and extractants of the tissue samples were tested, and various columns were systematically tested. The mobile phase was composed of acetonitrile and citric buffer at pH 4.5, with an initial composition of acetonitrile-water (12:88, v/v) and using linear gradient elution. Recoveries were 66-91% in the concentration range 30-300 microg kg(-1). The detector response was linear in this range. The limits of detection were 16-30 microg kg(-1). These values were lower than the maximum residue limits established by the European Union.  相似文献   

5.
The authors' laboratory at one time employed four liquid chromatography/mass spectrometric (LC/MS) methods for the detection of a large variety of drugs in equine urine. Drug classes covered by these methods included anti-diabetics, anti-ulcers, cyclooxygenase-2 (COX-2) inhibitors, sedatives, corticosteroids, anabolic steroids, sulfur diuretics, xanthines, etc. With the objective to reduce labour and instrumental workload, a new ultra performance liquid chromatography/tandem mass spectrometric (UPLC/MS/MS) method has been developed, which encompasses all target analytes detected by the original four LC/MS methods. The new method has better detection limits than the superseded methods. In addition, it covers new target analytes that could not be adequately detected by the four LC/MS methods. The new method involves solid-phase extraction (SPE) of two aliquots of equine urine using two Abs Elut Nexus cartridges. One aliquot of the urine sample is treated with β-glucuronidase before subjecting to SPE. A second aliquot of the same urine sample is processed directly using another SPE cartridge, so that drugs that are prone to decomposition during enzyme hydrolysis can be preserved. The combined eluate is analysed by UPLC/MS/MS using alternating positive and negative electrospray ionisation in the selected-reaction-monitoring mode. Exceptional chromatographic separation is achieved using an UPLC system equipped with a UPLC(?) BEH C18 column (10 cm L×2.1 mm ID with 1.7 μm particles). With this newly developed UPLC/MS/MS method, the simultaneous detection of 140 drugs at ppb to sub-ppb levels in equine urine can be achieved in less than 13 min inclusive of post-run equilibration. Matrix interference for the selected transitions at the expected retention times is minimised by the excellent UPLC chromatographic separation. The method has been validated for recovery and precision, and is being used regularly in the authors' laboratory as an important component of the array of screening methods for doping control analyses of equine urine samples.  相似文献   

6.
A simple and sensitive liquid chromatography (LC) method was developed for the simultaneous determination of eight quinolones in pig plasma samples. The following two methods of detection were used: ultraviolet (UV) and mass spectrometry with electrospray ionization (ESI/MS). Sample preparation consisted of solid-phase extraction (SPE) on Strata X cartridges prior to the analysis by LC/UV or LC/ESI/MS. The recovery, linearity, limit of detection (LOD) and limit of quantification (LOQ), precision and accuracy of the method were evaluated using spiked pig plasma samples. The suitability of the method for pharmacokinetic studies was evaluated by determining the concentrations of enrofloxacin (ENR) and ciprofloxacin (CIP) also in pig plasma, after administration of 200mg of enrofloxacin per kilogram of fodder during 5 consecutive days.  相似文献   

7.
Two extraction methods were developed for the determination of triasulfuron in soil. Method I included extraction with methanol-phosphate buffer at pH 7 (2 + 1, v/v), liquid-liquid partition with dichloromethane, and cleanup on a liquid chromatographic Si adsorption solid-phase extraction tube. In Method II, Extrelut was added and the sample was then extracted with acetonitrile. In both cases, the extracts were analyzed by liquid chromatography (LC) with UV detection and the LC peak was confirmed by LC/mass spectrometry (MS). The 2 methods were tested on 3 soils having different physicochemical characteristics. Method I gave 83% average recovery and a determination limit of 0.4 microg/kg soil. Method II gave 67% average recovery and a determination limit of 2 microg/kg soil. Examples of application of Method I to field samples are reported.  相似文献   

8.
A LC method for corticosteroids (CC) determination in poultry feed using a Chromolith column and UV detection has been developed and validated. The method development involved the optimization of different hydro-organic mobile phases using methanol or ACN as organic modifiers, flow rate, and temperature. The optimum separation was achieved at 40 degrees C using ACN/water (21:79 v/v) as mobile phase and 3 mL/min flow rate, allowing the separation to baseline of four out of seven CC in about 10 min. Prior to LC, a sample preparation procedure previously assayed for anabolics was used. It includes a leaching process, saponification of the esters from fatty acids, and SPE. Method validation was carried out according to the EU criteria established for quantitative screening methods. The extraction efficiencies, decision limits (CCalpha), and detection capabilities (CCbeta) for these compounds were in the ranges of 86-92%, 27-36 microg/kg, and 33-43 microg/kg, respectively. The repeatability and the within-laboratory reproducibility at 1, 1.5, and 2 CCbeta concentration levels were smaller than 9.0, 5.0, and 4.2% and 9.4, 6.4, and 4.9%, respectively. The CV values of the robustness test were less than 3.8% and the accuracy was in the range of 98-103%. The proposed method was applied to other feed with satisfactory results.  相似文献   

9.
A method has been developed for the target analysis of over 100 pesticides and contaminants in a complex feed matrix. The method is based on extraction with ethyl acetate, cleanup by gel permeation chromatography (GPC) and dispersive solid-phase extraction (SPE) with primary secondary amine phase (PSA), and analysis by comprehensive two-dimensional gas chromatography with full scan time-of-flight mass spectrometric detection (GC x GC-TOF-MS). Parameters studied during method development included a dispersive SPE cleanup step after GPC, large volume injection into the GC system and the GC x GC separation. Qualitative and quantitative performance of the GC x GC system was evaluated by analyzing spiked extracts in the range equivalent to 1-100 microg/kg in feed. At levels of 50 microg/kg and higher, all compounds targeted for could be identified fully automatically by the software based on their mass spectra. At lower levels the hit rate decreased with the concentration. System linearity was excellent in solvent and only slightly affected by matrix (correlation coefficients r>or=0.995 for 90% of the compounds). Limits of quantification were in the 1-20 microg/kg range for most compounds. The overall method was validated for 106 compounds at the 10 and 100 microg/kg level. Recoveries between 70% and 110% and RSDs below 20% were obtained for the majority of the compounds.  相似文献   

10.
Wang C  Lü Y  Xu R  Chen Y  Yin K  Teng E 《色谱》2011,29(3):212-216
建立了一种液相色谱-二极管阵列检测器(LC-DAD)/离子阱质谱(IT MS)对水中5种微囊藻毒素(microcystins)的分析方法。水中的微囊藻毒素经固相萃取富集和净化,经LC分离后,采用DAD和IT MS定性分析,DAD定量分析。在优化的条件下,水中5种微囊藻毒素的检出限为0.1 μg/L; 3个质量浓度加标水平(0.2、0.8和5 μg/L)的平均回收率为52.2%~115.2%,相对标准偏差为1.2%~10.0%。该方法从紫外吸收光谱和质谱角度同时进行定性定量分析,可用于地表水和饮用水中多种微囊藻毒素的检测。  相似文献   

11.
A rapid analytical method based on liquid chromatography/tandem mass spectrometry (LC/MS/MS) using electrospray ionization in negative ion detection mode was developed for the analysis of underivatized iodoacetic acid in water. The method was applied to model reaction mixtures in the study of the formation of iodoacetic acid after chlorinated tap water was boiled in the presence of potassium iodide or iodized table salt. Samples can be directly analyzed by the LC/MS/MS system without extraction or chemical derivatization. Limit of detection was determined to be 0.3 microg/L (or 0.3 ng/mL) and limit of quantitation was about 1 microg/L (1 ng/mL).  相似文献   

12.
Acetyl gestagenic steroids are isolated from animal tissues such as bovine kidney fat by automated supercritical fluid extraction (SFE). After the addition of internal standards and sample pretreatment, the analytes are extracted from the matrix by supercritical CO2 and trapped directly in-line on alumina placed in the extraction vessel. The samples are analysed by liquid chromatography combined with ion-trap mass selective detection (LC-MSn). For quantification, deuterated internal standards are added and single ions of the analytes and internal standards are monitored. For confirmation of the identity of the analytes, two transition ions (one MS2 and one MS3) were monitored and the ratios between the ions were calculated and compared with those of standards. The detection capability for the multi-analyte LC-MSn analysis of megestrol acetate (MA), medroxyprogesterone acetate (MPA), chlormadinone acetate (CMA) and melengestrol acetate (MGA) is 0.5 microg kg(-1). The mean within-laboratory reproducibility ranges from 16-19% (%RSD) at a concentration level of 0.5 microg kg(-1) (n = 9). Running the SFE procedure overnight allows the analysis of 24 samples of fat per day.  相似文献   

13.
A method of detecting and quantifying dehydroepiandrosterone (DHEA) sulfate, corticosteroids, and androgens has been developed. All of the compounds were first extracted from urine using solid phase extraction (SPE), enzymatically hydrolyzed, and separated into three samples using a second SPE. A DHEA sulfate sample was acetylated and re-extracted using SPE for purification before analysis. Corticosteroid samples were oxidized and re-extracted using liquid/liquid extraction for analysis. Androgen samples were acetylated and re-extracted using SPE prior to analysis. The extraction and analysis methods were investigated and optimized. Analyses were performed with gas chromatography/mass spectrometry (GC/MS) and gas chromatography/flame ionization detection (GC/FID). The entire procedure was then applied to the study of urine profiles of healthy volunteers and patients treated with corticosteroids. The results showed that the quantities of androgens found in patient urines were lower than in those of healthy volunteers. In addition, other metabolites were detected in patient urines.  相似文献   

14.
A new method is presented for the determination of 12 acidic pharmaceuticals (non-steroidal anti-inflammatory drugs and bezafibrate), including two metabolites from aqueous samples, together with triclosan as a personal care product. Ion-pair liquid chromatography (IP-LC) with electrospray ionisation tandem mass spectrometry (ESI-MS) in the negative ion mode was employed. The ion-pairing agent (tri-n-butylamine) increased the signal intensity for all acidic analytes and detection limits of 6-200 ng/L were obtained by multiple reaction monitoring. This allows analysis of wastewater samples by direct injection into the LC/MS system without the need for a preceding enrichment step. When combined with a solid-phase extraction (SPE) step, limits of quantification between 0.15 and 11 ng/L were obtained from 100-mL sample volumes, which is adequate for most applications. The occurrence of matrix effects was studied and standard addition was required for reliable quantification after SPE from wastewater. The method was finally applied to surface and wastewaters, with analyte concentrations ranging from below the detection limit up to 5.5 microg/L.  相似文献   

15.
Polyclonal antibodies against microcystin-LR (MC-LR), a cyclic heptapeptide toxin, were generated in rabbits using MC-LR-BSA. An enzyme-linked immunosorbent assay (ELISA) was developed for the characterization of the antibodies and their potential use for analytical purposes. The concentration of MC-LR that inhibits 50% of antibody-antigen binding (IC50) was 0.5 μg L−1 for the indirect ELISA format and 0.9 μg L−1 for the direct ELISA, using MC-LR-horseradish peroxidase conjugate. The limit of detection corresponding to IC80 was found to be 0.06 μg L−1, well below the Word Health Organization level for drinking water of 1 μg L−1. The direct competitive ELISA was applied to water samples and was shown useful for screening purposes. The developed anti-microcystin antibodies were immobilized on solid supports for use in selective solid phase extraction (SPE) systems, prior to liquid chromatography (LC) quantification. An immunoaffinity cartridge (IAC), a Sepharose®-based cartridge incorporating 2 mg of antibodies allowed the selective and quantitative recovery of a mixture of 0.2 μg of MCs showing potential use in sample preparation of real matrices. When applied to water and green algae samples, average recoveries from Sepharose®-based cartridges were in the range of 86-113% for water samples and 85-92% for blue-green algae samples. Selectivity of the IAC clean-up was proven by comparison with non-specific solid phase extraction using octadecylsilica (ODS) sorbent. Results obtained using LC/UV after IAC clean-up agreed well with results obtained using liquid chromatography and mass spectrometry detection (LC/MS and LC/MS/MS) after SPE-C18 clean-up, allowing therefore to validate the resulting technique.  相似文献   

16.
Haloacetic acids (HAAs) were determined in different water samples by a new, fast and simple analysis method based on enrichment of 50-ml water samples at pH 1.8 by solid-phase extraction (SPE) followed by liquid chromatography (LC) separation and electrospray ionization mass spectrometric detection in the negative ionization mode. Deprotonated (M-H)-haloacetates and decarboxylated (M-COOH)- ions were detected. Different polymeric SPE sorbents were tested, and LiChrolut EN was found to be the best material for the extraction. Complete LC separation of all compounds could only be achieved by ion-pair chromatography using triethylamine as volatile ion-pairing reagent. The detection limits were in the low microg/l range. High microg/l concentration levels for the chlorinated and brominated haloacetates were found in drinking water from a drinking water treatment plant in Barcelona, and the corresponding tap water. In swimming pool water samples from Catalonia mg/l levels and in surface river water from Portugal microg/l values were detected. These results confirm other recent reports on the ubiquitous occurrence of HAAs in aqueous environments.  相似文献   

17.
A method for the simultaneous quantitative determination of deoxynivalenol (DON), T‐2 toxin (T‐2), HT‐2 toxin (HT‐2) and zearalenone (ZEN) in wheat and biscuit by liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI‐MS/MS) coupled with immunoaffinity extraction is described. A clean‐up was carried out using a DZT MS‐PREP® immunoaffinity column (IAC), and the effect of the sample dilution rate and sample loading was investigated. Furthermore, the effects of ion suppression of a multifunctional column (MFC) and the IAC in the clean‐up were compared. The results with the DZT MS‐PREP® IAC showed that it is possible to make the sample dilution rate low, and indicated a higher solvent‐tolerance than usual with an IAC. Sample loading was optimized at 0.25 g. Ion suppression was lowered by purification of the toxins using the DZT MS‐PREP® IAC. Recoveries of each mycotoxin from wheat and biscuit samples spiked at two levels ranged from 78 to 109%. The limits of detection in wheat and biscuit was in the range of 0.03–0.33 ng·g?1. From these studies, it is suggested that use of an IAC is effective in the clean‐up of each mycotoxin, and, when combined with LC/ESI‐MS/MS, it is good for the determination of mycotoxins in foodstuffs due to its rapidity and high sensitivity. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

18.
A selective and accurate LC/MS/MS method for the simultaneous determination of chlortetracycline (CTC), oxytetracycline (OTC), tetracycline (TC), and doxycycline (DC) in animal feeds was developed. Samples were extracted with Na2EDTA-McIlvaine buffer and further purified with Oasis HLB SPE columns. The purified extract was separated on an Xbridge C18 column and detected by LC/MS/MS with positive electrospray ionization in the multiple reaction monitoring mode. This method provided average recoveries of 80.9 to 119.5%, with CVs of 1.7 to 9.8% in the range of 0.5 to 50 mg/kg CTC, OTC, TC, and DC in feeds, except the average recovery of CTC was 76.0%, with a CV of 14.6% in pig feed spiked with 0.5 mg/kg CTC. The linear ranges for the four TCs determined by LC/MS/MS ranged from 0.005 to 2.5 microg/mL with a linear correlation coefficient (R2) >0.99. The LOD and LOQ for CTC, OTC, TC, and DC in pig and poultry feeds ranged from 0.003 to 0.02 and 0.01 to 0.05 microg/g, respectively. The method was successfully applied for the analysis of 30 real feed samples, and no illegal use was detected.  相似文献   

19.
The avermectin and milbemycin families of compounds are derived from naturally occurring yeasts. They have proven to be potent preventatives against a variety of pests such as insects and parasites. Only eprinomectin and moxidectin are currently approved for use on lactating cattle with tolerances in milk of 12 microg/kg for eprinomectin and 40 microg/kg for moxidectin. Detection of misuse or inadvertent contamination in milk requires a sensitive and definitive analytical method. A method has been developed for the determination of 5 avermectins and 1 milbemycin in milk using a simple liquid-liquid extraction and liquid chromatography/tandem mass spectrometry (LC/MS/MS) analysis. Ivermectin (IVR), doramectin (DOR), abamectin (ABA), eprinomectin (EPR), emamectin (EMA), and moxidectin (MOX) were extracted from whole milk by partitioning into acetonitrile with a subsequent solvent exchange into methanol-water. Simultaneous confirmation and quantification were achieved with LC separation, positive electrospray ionization (ESI+), and MS/MS. The limits of detection ranged from 16 pg/g (ppt) for EMA to 1.7 microg/g (ppb) for MOX.  相似文献   

20.
Alkylphenols are nonbiodegradable metabolites arising from various pathways of aerobic and anaerobic degradation of the nonionic surfactants alkylphenol ethoxylates. A method based on the use of on-line solid-phase extraction (SPE) and liquid chromatography (LC) with UV detection was developed to determine bisphenol A, octylphenol, and nonylphenol at trace levels in water. The on-line coupled SPE procedure automatically enables an approximately 300-fold preconcentration of analytes, which can be further enhanced by an increase in applied sample volume. By using C18 cartridges, recoveries of >90% were obtained for all the analytes. A validation procedure was carried out with a groundwater sample to ensure the quality of the results; performance criteria such as detection limits (LODs), quantitation limits (LOQs), linearity, and precision were evaluated. LODs and LOQs in the range of 0.17-0.36 and 0.35-1.88 microg/L, respectively, were found; for all the analytes, linearity was established over 2 orders of magnitude (r2 >0.997, n = 54). The intraday repeatability values expressed as relative standard deviations were <5.3%; a nested analysis of variance was performed to verify the influence of 3 different factors, i.e., different days, extraction procedure, and LC replicate injection, on data precision.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号