首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 26 毫秒
1.
The retention behavior of primary aliphatic amines (homologous series of aliphatic alkyl amines and cycloalkyl amines) and positional isomers of alkylamines in the hydrophilic interaction chromatography mode was studied. The study was carried out on a TSKgel Amide‐80 column followed by postcolumn derivatization with fluorescence detection to describe the retention mechanism of tested compounds. The effect of chromatographic conditions including column temperature, acetonitrile content in the mobile phase, mobile phase pH (ranging from 3.5 to 6.8), and salt concentration in the mobile phase was investigated. The final mobile phase consisted of acetonitrile and solution of 20 mM potassium formate pH 3.5 in ratio 80:20 v/v. The analyses were carried out at mobile phase flow rate of 1.0 mL/min and the column temperature of 20°C. The developed method was fully validated in terms of linearity, sensitivity (limit of detection and limit of quantification), accuracy, and precision according to International Council for Harmonisation of Technical Requirements for Pharmaceuticals for Human Use guidelines. The proposed new methods were proved to be highly sensitive, simple, and rapid, and were successfully applied to the determinations of isopropylamine, cyclohexylamine, and cyclopropylamine in relevant active pharmaceutical ingredients.  相似文献   

2.
The amino alcohols in l‐ valinol were effectively separated and quantified using hydrophilic interaction chromatography with fluorescence detection. The influence of the mobile phase (salt type, buffer concentration, and pH) on retention was studied. A column TSKgel amide and mobile phase consisting of 10 mM acetate buffer pH 4.0 and acetonitrile (20:80, v/v) provided well‐ separated symmetric peaks of analytes. Fluorescence detection was performed using postcolumn derivatization with o‐phtaldialdehyde/2‐mercaptoethanol at an excitation and emission wavelength of 345 and 450 nm, respectively. Simple sample pretreatment and very high sensitivity represent the main advantages of the developed method. After validation, the method was successfully applied to the analysis of commercial samples of l‐ valinol.  相似文献   

3.
As part of our program to develop more stable cyano (CN) high-performance liquid chromatography (HPLC) column packings, we have evaluated hydrolytic stability as a function of ligand connectivity, chain length, and side group steric protection and the pH of the mobile phase. Three accelerated tests were used to evaluate stability: (1) A non-HPLC screening test measuring carbon loss in refluxing MeOH-100 mM KH2PO4 pH 4.5 (1:1, v/v) solution; (2) a continuous flow HPLC test measuring capacity factor maintenance in 1% trifluoroacetic acid in water (pH 1.02) at 80 degrees C; and (3) a continuous flow HPLC test measuring column efficiency maintenance in 50 mM triethylamine in water (pH 10.00) at 50 degrees C. The stability of the CN phases was found to be dependent on both ligand chemical structure and the pH of the test conditions. The starting screen test of intermediate pH was least able to differentiate the CN phases based on structure, because two different degradation mechanisms appear to offset each other (acid induced siloxane bond cleavage vs. base induced silica dissolution). A trifunctional and a sterically protected CN phase were notably stable under the acidic test conditions, but had poor stability under basic conditions. Conversely, chain extension afforded poor stability under acidic conditions, but did afford improved stability at higher pH. In total, the data indicate that good CN column stability can be achieved by using a trifunctional or a sterically protected phase in acidic mobile phases. However, as mobile phases of intermediate or higher pH are employed, shorter column lifetimes can be expected due to an accelerated dissolution of the underlying silica substrate. Materials were also compared chromatographically using a mixture of non-polar, polar, and basic analytes under reversed-phase conditions.  相似文献   

4.
The chemiluminescent reaction of bis(2,4,6-trichlorophenyl) oxalate (TCPO) in aqueous micellar systems is compared with the reaction in a mixture of acetonitrile and aqueous phosphate buffer. The chemiluminescence was studied in batch experiments with perylene as the fluorophore. The oxidation of TCPO produced the same intensity of chemiluminescence in the buffered acetonitrile as in Arkopal N-300 micelles, the best micellar system. The solubility of TCPO in an aqueous micellar system is greater than that in the acetonitrile/aqueous buffer (80:20, v/v), but TCPO is less stable in the former system.  相似文献   

5.
The chemiluminescence reaction between an aryl oxalate, hydrogen peroxide and a fluorescent compound is well known for use in h.p.l.c. post-column reactors. Here, several aryl oxalates are evaluated for this purpose in terms of intensity, rate of chemiluminescence decay, solubility in different solvents, and stability in the presence of hydrogen peroxide. Five oxalates are selected for different pH ranges of column eluates: bis(pentafluorophenyl) oxalate for pH < 2, bis(2,4-dinitrophenyl) oxalate for pH 2–4, bis(2-nitrophenyl) oxalate for pH 4–6, bis(2,4,6-trichlorophenyl) oxalate for pH 6–8, and bis(2,4,5-trichlorophenyl-6-pentyloxycarbonyl) oxalate for pH > 8.  相似文献   

6.
In this study, the separation of biologically active peptides on two zirconia-based phases, polybutadiene (PBD)-ZrO2 and polystyrene (PS)-ZrO2, and a silica-based phase C18 was compared. Basic differences in interactions on both types of phases led to quite different selectivity. The retention characteristics were investigated in detail using a variety of organic modifiers, buffers, and temperatures. These parameters affected retention, separation efficiency, resolution and symmetry of peaks. Separation systems consisting of Discovery PBD-Zr column and mobile phase composed of a mixture of acetonitrile and phosphate buffer, pH 2.0 (45:55, v/v) at 70 degrees C and Discovery PS-Zr with acetonitrile and phosphate buffer, pH 3.5 in the same (v/v) ratio at 40 degrees C were suitable for a good resolution of enkephalin related peptides. Mobile phase composed of acetonitrile and phosphate buffer, pH 5.0 (22:78, v/v) was appropriate for separation of enkephalins on Supelcosil C18 stationary phase.  相似文献   

7.
The separation of basic compounds in high-pH mobile phases results in extended retention, excellent peak shapes and good chromatographic efficiency. A severe decrease in sensitivity with electrospray mass spectrometric detection in positive ion mode (ESI+-MS) is expected under conditions that suppress analyte ionization in solution. We compared the responses of a large number of various basic drugs covering a wide range of hydrophobic (log P 0.09 to 7.6) and basic character (pKa 6.8-10) in LC-ESI+-MS/MS in 0.1% formic acid in water and acetonitrile, to responses in 10mM ammonium hydrogencarbonate buffers of different pH (7.8-11), and acetonitrile. Contrary to common expectations, high-pH mobile phases do not affect negatively the responses of basic compounds in ESI+. Analyte responses and limits of detection are comparable, or most often better in high pH compared to acidic mobile phases.  相似文献   

8.
A high performance liquid chromatographic assay of methamphetamine (MP) and its related compounds, i.e. ephedrine (EP), norephedrine (NE), p-hydroxymethamphetamine (p-HMP), p-hydroxyamphetamine (p-HAP) and amphetamine (AP), with peroxyoxalate chemiluminescence detection has been developed. 4-(N,N-Dimethylaminosulphonyl)-7-fluoro-2,1,3-benzoxadiazole (DBD-F) was used as a fluorescent labeling reagent. A mixture of hydrogen peroxide and bis[4-nitro-2-(3,6,9-trioxadecyloxycarbonyl)phenyl] oxalate in acetonitrile was used as a postcolumn chemiluminogenic reagent. DBD derivatives of MP and its related compounds were separated by a gradient elution with acetonitrile and 0.01 M imidazole buffer (pH 7.0) within 65 min. The detection limits (S/N = 3) for the proposed method for MP, AP, EP, NE, p-HMP and p-HAP were 27, 100, 40, 133, 25 and 133 fmol on column, respectively. The recoveries of these compounds with normal urine samples were 87.4-106.4%. The method was successfully applied to the assay of MP and its metabolites in urine samples from MP addicts. A good linear correlation for the resulted amounts of MP or AP between the proposed method and gas chromatography was obtained (r = 0.993 for MP or 0.991 for AP).  相似文献   

9.
A sensitive chemiluminescence high-performance liquid chromatographic method has been developed for the determination of hyaluronic acid, chondroitin sulphate and dermatan sulphate as their unsaturated disaccharide-dansylhydrazine derivatives involving an effective sample clean-up system. The dansylhydrazones of the unsaturated disaccharides derived from the hyaluronic acid, chondroitin sulphate and dermatan sulphate by chondroitinase ABC and/or chondroitinase ACII, were separated by reversed-phase chromatography using a mixture of 0.1 M sodium acetate buffer (pH 6.0) and 80% acetonitrile on a column (250 mm x 4.0 mm I.D.) packed with amide-80 silica beads (5 microns diameter). For post-column elution in the chemiluminescence system, 1 mM bis[2-(3,6,9-trioxadecanyloxycarbonyl)-4-nitrophenyl]oxalate and 3mM hydrogen peroxide in acetonitrile were used. The detection limit of each glycosaminoglycan was 100 fmol. The method was applicable to the determination of the levels of hyaluronic acid, chondroitin sulphate and dermatan sulphate in rat peritoneal mast cells.  相似文献   

10.
王智聪  傅荣杰  吉建国  陈波 《色谱》2019,37(2):201-206
采用高分辨采样二维液相色谱法(HiRes 2D-LC)对金银花中绿原酸和木犀草苷进行准确定量分析。第一维液相色谱采用C18色谱柱,以乙腈和0.4%(v/v)磷酸水溶液为流动相进行梯度洗脱;第二维液相色谱采用SB-Phenyl色谱柱,以乙腈和0.5%(v/v)乙酸水溶液为流动相进行梯度洗脱;二维接口采用五位十通阀,并配置2个多中心切割阀,对绿原酸组分和木犀草苷组分进行多次连续切割。实验结果表明,二维液相色谱分析提高了绿原酸和木犀草苷色谱峰的确认能力,可揭示一维液相色谱分析中共洗脱或隐藏峰的信息;高分辨采样模式实现了一维目标组分的片段式整峰切割,提高了二维液相色谱分析的准确定量能力;通过线性关系、基质加标回收和重复性等考察结果,表明高分辨采样二维液相色谱具有优异的定量准确性和重复性,为中药等复杂基质组分样品的分离和准确定量提供了新方法。  相似文献   

11.
The peroxyoxalate chemiluminescence(CL) detection method for the evaluation of the CL intensity of malondialdehyde(MDA) condensates with seven 2-thiobarbituric acid derivatives is described. The method consists of a flow injection technique together with a CL detection system using bis(2,4,6-trichlorophenyl) oxalate(TCPO) and hydrogen peroxide as chemiluminogenic reagents. Linear correlations between CL intensity and concentration are obtained for pmol levels of condensates. Among the condensates, 1,3-diethyl-2-thiobarbituric acid(DETBA)-MDA shows the largest CL intensity. High performance liquid chromatography (HPLC)/CL detection of DETBA-MDA and 1,3-diphenyl-2-thiobarbituric acid(DPTBA)-MDA using a mixture of TCPO and hydrogen peroxide in acetonitrile as a postcolumn reagent solution is also described. The detection limits for DETBA-MDA and DPTBA-MDA are 20 and 200 fmol, respectively, per 20 microL injection at a signal-to-noise ratio of 2. This HPLC/CL detection system was applied to the determination of MDA in rat brains by using DETBA as a fluorescent derivatizing reagent.  相似文献   

12.
王萍亚  周勇  戴意飞  黄鹂  赵巧灵 《色谱》2015,33(8):822-829
利用超高效液相色谱-四极杆飞行时间质谱(UPLC-Q-TOF MS)技术建立了水产品中28种酸性合成色素的快速检测方法。水产样品采用氨水-水-乙醇(2:1:7, v/v/v)溶液提取,经氨基化吸附剂基质分散法净化后直接用UPLC-Q-TOF MS测定。目标物经Eclipse Plus-C18柱分离,以0.1%(v/v)甲酸-5 mmol/L乙酸铵水溶液和乙腈为流动相进行梯度洗脱,采用电喷雾负离子模式下全信息串联质谱扫描模式进行检测。结果表明:水产品中28种酸性合成色素的定量限(LOQ, S/N=10)为20~100 μg/kg;并在各自的线性范围内线性关系良好(相关系数r)≥0.991,峰面积的相对标准偏差(n=6)均小于5.61%;在3个加标水平下的平均回收率为70.24%~106.47%,相对标准偏差为5.62%~9.65% (n=6)。该方法快速简单、灵敏度高,适用于水产品中28种色素的快速筛查。  相似文献   

13.
For the quantitative determination of trovafloxacin (a new naphthyridinone antibacterial agent) in serum and urine a simple isocratic HPLC method with fluorimetric detection is described. Serum was deproteinised with a mixture of acetonitrile and perchloric acid. The protein-free extract was separated on a reversed-phase column (Nucleosil 100-5 C18) and quantified by means of fluorescence (excitation 275 nm, emission 405 nm). The mobile phase consisted of a mixture of 250 ml acetonitrile and 750 ml distilled water containing 10 mmol/l tetrabutylammonium phosphate. Urine was diluted with 0.25 mol/l phosphoric acid 1:20 (v/v) which was adjusted to pH 3.6 with sodium hydroxide solution. Diluted urine samples were separated on a cation-exchange column (Nucleosil 100-5 SA) and also detected by means of fluorescence. Trovafloxacin was sufficiently separated from endogenous compounds. Results of validation are given. The method was applied successfully to a study of healthy volunteers.  相似文献   

14.
The solvation parameter model system constants and retention factors were used to interpret retention properties of 39 calibration compounds on a biphenylsiloxane-bonded stationary phase (Kinetex biphenyl) for acetone-water binary mobile phase systems containing 30–70% v/v. Variation in system constants, phase ratios, and retention factors of acetone-water binary mobile phases systems were compared with more commonly used acetonitrile and methanol mobile phase systems. Retention properties of acetone mobile phases on a Kinetex biphenyl column were more similar to that of acetonitrile than methanol mobile phases except with respect to selectivity equivalency. Importantly, selectivity differences arising between acetone and acetonitrile systems (the lower hydrogen-bond basicity of acetone-water mobile phases and differences in hydrogen-bond acidity, cavity formation and dispersion interactions) could be exploited in reversed-phase liquid chromatography method development on a Kinetex biphenyl stationary phase.  相似文献   

15.
The reduction of iodine with azide, catalyzed by polythionates (tri-, tetra-, penta- and hexathionate) and thiosulfate, has been utilized as a postcolumn reaction for chromatographic determination of these sulfur oxyanions. The method is based on the separation of polythionates and thiosulfate on an octadecylsilica column with an acetonitrile–water (20:80, v/v) mobile phase (pH 5.0) containing 3 mM tetrapropylammonium hydroxide and 6 mM acetic acid, followed by photometric measurement of the residual iodine (as triiodide) from the catalytic postcolumn azide–iodine reaction after mixing a reaction solution containing azide and iodine with the column effluent. Chromatograms obtained for the sulfur oxyanions showed negative peaks as a result of the decrease in absorbance of background. The conditions for the catalytic postcolumn reaction of the sulfur oxyanions in the column effluents were established by varying the concentrations of azide, iodine, iodide and acetic acid in the reaction solution, and varying the flow-rate, reaction temperature and length of the reaction tube. The detection limits (defined as S/N=3) were 4.3 μM for trithionate, 0.10 μM for tetrathionate, 2.7 nM for pentathionate, 5.0 nM for hexathionate and 1.1 nM for thiosulfate. When compared with earlier methods, the proposed method gave a much higher sensitivity for the determination of two polythionates (penta- and hexathionate) and thiosulfate. This method was applied successfully to the analysis of polythionates and thiosulfate added to hot-spring water samples.  相似文献   

16.
The reversed-phase high-performance liquid chromatography of three synthetic opioid peptides, 5leucine-enkephalin, 5methionine-enkephalin and [D-2alanine]-5methionine enkephalin, has been studied after their pre-column fluorogenic derivatization with naphthalene-2,3-dicarboxaldehyde in the presence of cyanide to the corresponding 1-cyanobenz[f]isoindole (CBI) derivatives. The chromatographic properties of the three synthetic CBI-peptides were characterized using three different stationary phases, ODS Hypersil, CPS Hypersil and Spherisorb Phenyl, eluted with mobile phases containing various concentrations of methanol, tetrahydrofuran or acetonitrile in 26 mM trifluoroacetic acid, adjusted to pH 3.5. The data obtained using single chromatographic columns were used to design a multi-dimensional system in which the three synthetic CBI-peptides of interest were transferred as a single fraction from one column to a second. The first column served to separate the peptides from the majority of the material in the samples, and the second column was used to separate the three CBI-peptides from each other. The best separation was achieved in which the first column was Spherisorb Phenyl and the second column was ODS Hypersil. Both columns were eluted with a mobile phase of 45% acetonitrile (v/v) in 26 mM trifluoroacetic acid (pH 3.5) at a flow-rate of 1.0 ml/min. The method has been applied to the determination of leucine- and methionine-enkephalin-like fluorescence in the striatum of the rat brain.  相似文献   

17.
A dual-head short-stroke pump has two advantages in the post-column peroxyoxalate chemiluminescence (PO-CL) detection system. The first is to increase the mixing efficiency of solutions. The second is to increase the stability of the PO-CL reaction by keeping the aryl oxalate and hydrogen peroxide solutions separate. The detection sensitivities for six polycyclic aromatic hydrocarbons (PAHs) increased in the present system by using bis(2,4-dinitrophenyl) oxalate (DNPO) or bis(2,3,4,5,6-pentafluorophenyl) oxalate (PFPO) instead of such popular aryl oxalates as bis(2,4,6-trichlorophenyl) oxalate (TCPO) and bis[2-(3,6,9-trioxadecyloxycarbonyl)-4-nitrophenyl] oxalate (TDPO). Both DNPO and PFPO increased the sensitivities by factors of 4.1-10.2 and 3.5-8.1, respectively. In addition, DNPO was more stable than PFPO in acetonitrile. These results suggest that DNPO is the most useful aryl oxalate for the sensitive PO-CL detection of PAHs.  相似文献   

18.
A simple, robust, and rapid reversedphase high-performance liquid chromatographic method for the analysis of demeclocycline and its impurities is described. Chromatographic separations were achieved on a Symmetry Shield RP8 (75 mm × 4.6 mm, 3.5 μm) column kept at 40°C. The mobile phase was a gradient mixture of acetonitrile, 0.06 M sodium edetate (pH 7.5), 0.06 M tetrapropylammonium hydrogen sulphate (pH 7.5) and water, A (2:35:35:28 v/v/v/v) and B (30:35:35:0 v/v/v/v) pumped at a flow rate of 1 mL/min. UV detection was performed at 280 nm. The developed method was validated according to the ICH guidelines for specificity, limit of detection, limit of quantification, linearity, precision, and robustness. An experimental design was applied for robustness study. Results show that the peak shape, chromatographic resolution between the impurities, and the total analysis time are satisfactory and better than previous methods. The method has been applied for the analysis of commercial demeclocycline bulk samples available on the market.  相似文献   

19.
有机酸类化合物的反相高效液相色谱法的分离条件研究   总被引:53,自引:6,他引:53  
赵景婵  郭治安  常建华  王文君 《色谱》2001,19(3):260-263
 研究了在用RP HPLC法测定有机酸时如何对流动相的酸度进行控制 ,给出了流动相最佳pH的选择通式 :色谱柱允许的最低 pH值≤pH≤pKa- 2 ;研究了流动相中甲醇、乙腈存在时对此通式的影响。用研究得出的结论选择了测定甲酸、乙酸、丙酸、丁酸和丙二酸、丁二酸、戊二酸、己二酸时的色谱条件 ,并且研究了每种酸在各自浓度范围内测定的线性关系、回归方程、相关系数以及相对标准偏差。实验显示 ,在选定的色谱条件下进行分析测试时 ,各种酸的线性相关系数r >0 9995 ,相对标准偏差RSD <0 90 %。  相似文献   

20.
In general, the reduction of disulfide bonds with tris(2-carboxyethyl)phosphine (TCEP) is performed using off-line operation, which is not only time-consuming but also vulnerable to the spontaneous re-oxidation of thiols during sample preparation and subsequent analysis procedures. To the best of our knowledge, there has been not any case on the on-line reduction for biological disulfides coupled with high performance liquid chromatography (HPLC). In this study, these obstacles are overcome by packing Zn(II)-TCEP complexes into a home-made column. The as-synthesized Zn(II)-TCEP complexes enable efficient reduction of disulfide bonds at pH 3.0. This acidic pH value was compatible with that of the mobile phase for HPLC separation of thiols and disulfides. Therefore, using fluorosurfactant-prepared triangular gold nanoparticles as HPLC postcolumn specific chemiluminescence (CL) reagents for thiols, the feasibility of the established on-line reduction column has been confirmed for the direct identification of both thiols and disulfides by incorporating this reduction column into a single chromatographic separation. Detection limits for these analytes range from 8.3 to 25.4 nM and the linear range in a log–log plot can comprise three orders of magnitude. Finally, the utility of this automated on-line reduction of disulfides-HPLC-CL system has been demonstrated for the reliable determination of thiols and disulfides in human urine and plasma samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号