首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 187 毫秒
1.
A simple and sensitive spectrophotometric method for the determination of a thiobarbituric acid-reactive substance (TBARS) in human hair has been developed. The proposed method is based on the formation of a red-colored product by the reaction of products of lipid peroxidation with thiobarbituric acid in an acidic medium. The absorbance of the resulting red product was measured at 534 nm. The linear dynamic range was between 1.0 and 20 micromol/L. The recoveries were 98.3-105.0%, and the relative standard deviations (RSD) were 0.32-1.24, respectively. TBARS in digested hair sample was stable for 3 days at room temperature. It was found that, using this method, the hair TBARS concentration in smokers (0.116 +/- 0.030 micromol/g, n = 30) was significantly higher than that in non-smokers (0.096 +/- 0.015 micromol/g, n = 30) (p < 0.05).  相似文献   

2.
A reversed phase high performance liquid chromatographic method for the simultaneous determination of pseudouridine (PU) and creatinine (Cr) in urine is described. The mobile phase was 0.01 mol phosphate buffer (pH 6.1) containing 2.5 mmol octanesulphonic acid as the ion pairing agent. UV detection was set at 250 nm. Variation in pH value affected the retention time of PU and Cr significantly; Their separation from interfering peaks was also affected. The recoveries of PU and Cr were 89.93% and 90.35%, respectively. The standard deviation of the method for PU was 48.69 +/- 0.063 (nmol/mumol Cr, mean +/- SD, n = 5). The urine samples from 233 normal children of different ages and 119 patients with leukaemia were analysed by this method. The normal reference value was appraised by comparison with the percentage of immature cells in the bone marrow. The results showed that the sensitivity of the method was 94.12%, the specificity was 95.86%, the accuracy was 95.50%, the positive predictive value was 82.05% and the negative predictive value was 98.78%. The method can be used to evaluate the state of the leukaemia, and to monitor the effect of treatment.  相似文献   

3.
A simple method is presented for the routine analysis of iodide in urine. After a one-step sample clean-up, iodide was separated by ion-pair reversed-phase liquid chromatography and detected electrochemically with a silver electrode. The coefficient of variation of a single analysis of iodide in a pooled urine sample (530 nmol/l) was 7.6%. The detection limit, derived from a signal-to-noise ratio of 3, was 3 pmol, corresponding to 0.06 mumol/l. The recovery of iodide added to urine was 96 +/- 7%. The accuracy of the method was assessed by analysing ten different samples with neutron activation analysis. The data obtained with the two methods showed a high correlation (r = 0.991) and did not differ significantly. Excretion of iodide in samples of 24-h urine from a free-living population was shown to have a log-normal distribution and to be higher in men than in women. The iodide/creatinine ratio was independent of sex and increased with age.  相似文献   

4.
A column-switching high-performance liquid chromatographic method, requiring no sample preparation apart from filtration, is described for quantification of urinary orotic acid, uracil and pseudouridine. The analyses were carried out using a reversed-phase octadecylsilane-bonded column for sample clean-up and a cation-exchange column for separation; 5-20 microliters samples of urine were directly analysed, and more than 100 samples could be analysed consecutively. Each sample required only 30 min. Detection limits of these compounds were 5 pmol. Creatinine-related urinary uracil excretion was lowest in the newborn period (17.3 +/- 14.4 mumol/g of creatinine). A patient with partial ornithine transcarbamylase deficiency and his mother usually excreted a high level of uracil during the period of normal orotic acid excretion and normal serum ammonia level.  相似文献   

5.
This paper describes the determination of acetylsalicylic acid (ASA) as salicylate (SA) in pharmaceutical formulations by using amperometric detection with copper electrodes in 0.10 mol l(-1) NaOH solution. Batch injection analysis (BIA) was explored for this application. The system exhibited sharp current response peaks, rapid washout and excellent repeatability. A large linear dynamic range from 1 to 1000 mumol l(-1) was obtained by using an injected volume of 100 mul, with a detection limit of 0.48 mumol l(-1). R.S.D. of 0.37% for 30 repetitive (1x10(-4) mol l(-1)) injections and sampling frequency of 60 h(-1) were achieved. The results obtained using this system for ASA determination in seven different drug samples compared well with those found by spectrophotometry (Trinder test).  相似文献   

6.
 一种新的衍生试剂9,10 蒽醌 2 磺酰氯(ASC)首次用于酚类衍生。几种不同极性的酚被用于评价该试剂。为便于考察ASC对酚衍生的机理及优化衍生条件,制备了不同酚的标准衍生物并对它们进行了结构确证。衍生过程涉及去质子酚与特丁基铵阴离子形成离子对后被有机溶剂提取。衍生反应可以在室温下3min内在两相界面上定量完成。衍生产物很稳定,可以分别被正相和反相分离(相应地在320nm或256nm波长处检测),其浓度和响应在0 2μmol/L~200μmol/L内存在很好的线性关系。  相似文献   

7.
高效液相色谱法同时测定假尿核苷和肌酐的研究及应用   总被引:4,自引:0,他引:4  
许丹科  谭力 《分析化学》1993,21(9):993-995
本文用高效液相色谱法同时测定人尿中假尿核苷和肌酐,研究了流动相的pH值变化对色谱行为的影响,方法简便、快速,已成功地用于对正常人、肺部感染及肺癌患者的尿样分析,其结果有显著性差异。  相似文献   

8.
A reversed-phase high-performance liquid chromatographic (HPLC) assay method has been developed for determining pirlimycin in human serum and urine. The method involves chloroform extraction of pirlimycin free base followed by derivatization with 9-fluorenylmethylchloroformate to form a carbamate ester. The reaction is rapid, reproducible, and quantitative. 9-Fluorenylmethylchloroformate reacts with amines to form derivatives sensitive to both ultraviolet and fluorescence detection. Human serum and urine samples following 50-mg and 500-mg single oral doses of pirlimycin were analyzed. The samples were chromatographed on an RP-18 Spherisorb 5-micron, 250 X 4.6 mm I.D. reversed-phase HPLC column. The eluent for the serum assay was acetonitrile-water (58:42) containing 0.02% acetic acid, and for the urine assay was acetonitrile-methanol-tetrahydrofuran-water (48:2:1:49). Fluoranthene was used as an internal standard. The assay sensitivity by ultraviolet detection (lambda max = 264) was about 5 ng/ml and by fluorescence detection (lambda excitation = 270 nm, lambda emission = 300 nm) was 0.1 ng/ml. Statistical analysis indicates an average drug recovery of 101 +/- 4.2% from serum and 102.0 +/- 2.62% from urine.  相似文献   

9.
We have developed a novel analyser for the determination of vanillylmandelic acid, homovanillic acid and creatinine in urine by high-performance liquid chromatography using three different types of column, cation-exchange, anion-exchange and reversed-phase and the column-switching technique. In this procedure, 10 microliters of intact urine were directly injected into the cation-exchange column, and the pass-through fraction, containing vanillylmandelic acid and homovanillic acid was transferred to the anion-exchange column by column switching. The fraction partially purified from endogenous urinary impurities on the anion-exchange column was transferred to the reversed-phase column. Vanillylmandelic acid and homovanillic acid, separated by the solvent-switching technique, were detected fluorimetrically (excitation at 280 nm, emission at 320 nm). Then, creatinine eluted from the cation-exchange column is spectrophotometrically detected (254 nm). Therefore the successive simultaneous analysis of the three could be performed in a 15-min cycle; the within-assay coefficients of variation for normal and patients' urines were less than 1.9%, less than 3.3% and less than 3.0% for vanillylmandelic acid, homovanillic acid and creatinine, respectively; the recoveries averaged 100, 103 and 100%, respectively, for supplemented urines.  相似文献   

10.
Non-protected fluid room temperature phosphorescence, NPRTP, has been applied to the determination of naftopidil in biological fluids. The proposed method is based on obtaining a phosphorescence signal from naftopidil using potassium iodide as heavy atom perturber and sodium sulfite as a deoxygenating reagent without a protected medium. Optimized conditions for the determination were 1.4 mol L= KI, 5.0 x l0(-3) mol L(-1) sodium sulfite, pH 6.5 (adjusted with sodium hydrogen phosphate-dihydrogen phosphate buffer solution, 5.0 x 10(-2) mol L(-1). The delay time, gate time, and time between flashes were 70 micros, 400 micros, and 5 ms, respectively. The maximum phosphorescence signal appeared instantly and the intensity was measured at lambda(ex)=287 nm and lambda(em)=525 nm. The response obtained was linearly dependent on concentration in the range 50 to 600 ng mL(-1). The detection limit, according to error-propagation theory, was 7.93 ng mL(-1) and the detection limit as proposed by Clayton was 11.12 ng mL(-1). The repeatability was studied by using ten solutions of 400 ng mL(-1) naftopidil; if the theory of error propagation is assumed the relative error is 0.88%. The standard deviation of replicates was found to be 3.5 ng mL(-1). This method was successfully applied to the analysis of naftopidil in human serum and urine with recoveries of 104.0 +/- 0.6% for serum and 106.0 +/- 1.0% for urine.  相似文献   

11.
A rapid urine creatinine assay by capillary zone electrophoresis.   总被引:4,自引:0,他引:4  
Using capillary zone electrophoresis, the urine creatinine (uCr) assay was validated in extemporaneous diluted urine, both in healthy subjects and athletes, with the uCr concentration as a reference value to compare excretion rates of other metabolites in the same samples. The electrokinetic sample injection was carried out at 10 kV per 10 s; UV absorbance detection was at 254 nm. Using standard samples, the creatinine migration mean time in 100 mmol/L acetate buffer, pH 4.4, was 3.3+/-0.2 min; the repeatability for absolute migration mean time was 0.6% and peak height repeatability was 2.9%. The correlation coefficient of the standard curve was r = 0.999 and the detection limit was 23.1 micromol/L. Intra- and interassay coefficients of variation (CV) were 3.0 and 3.6%, respectively; recovery was 99+/-3% and linearity was r= 0.98. Normal urine samples were diluted 1:80 in run buffer. The present CE urine creatinine assay showed a good correlation with HPLC and with Jaffe methods (r = 0.98 and r = 0.97, respectively; p < 0.0001). The uCr in the morning urine samples of 34 healthy males (M), 38 healthy females (F), and 83 male athletes (A) was 10.4+/-6.1 mmol/L, 10.8+/-8.1 mmol/L and 13.2+/-6.5 mmol/L, respectively. The uCr difference (p < 0.02) between M and A and a correlation (p < 0.05) with age in A were observed.  相似文献   

12.
Key metabolites for the diagnosis of the genetic disorder trimethylaminuria are trimethylamine (TMA) and trimethylamine N-oxide (TMAO). A rapid, automatable flow injection ESI-MS/MS method for their measurement in urine has been developed. The TMA was derivatized with ethyl bromoacetate to form ethyl betaine bromide. The 2 min ESI-MS/MS analysis employed four multiple reaction monitoring (MRM) ion pairs for derivatized TMA (146.1, 118.1), derivatized (2)H(9)-TMA (155.1, 127.1), TMAO (76.1, 58.1) and (2)H(9)-TMAO (85.1, 66.1). In control urine samples (n = 27) referred for suspected metabolic problems TMA was 0.11-1.19 mmol/mol creatinine, TMAO was 13.5-181 mmol/mol creatinine and the TMA/TMAO ratio was 0.0025-0.055. In five patients with diagnosed trimethylaminuria, TMA was 5.3-230 mmol/mol creatinine, TMAO was 0.36-607 mmol/mol creatinine and the TMA/TMAO ratio was 0.20-134.  相似文献   

13.
A column-switching liquid chromatographic method for the simultaneous determination of uric acid and creatinine in human serum and urine was developed. Creatinine and uric acid were separated by size-exclusion chromatography on a hydrophilic gel column (C1) and creatinine eluted from Cl was separated from proteins by filtration through a longer hydrophilic gel column (C2). The creatinine fraction eluted from C2 was transferred to a weakly acidic cation-exchange column (C3) and then to a strongly acidic cation-exchange column (C4). Uric acid eluted from Cl after creatinine was transferred to an anion-exchange column (C5) and then to a hydrophilic gel column (C6). The mobile phase was a mixed buffer of pH 5.1 (propionic acid-succinic acid-NaOH, 60:15:60 mmol/1 in water). Diluted serum and urine could be injected onto C1, and Cl was backflushed after the transfer of uric acid from Cl to C5.

Creatinine and uric acid in the eluate were determined by measuring their ultraviolet absorption at 234 and 290 nm, respectively. The recovery of uric acid and creatinine added to diluted serum (20-fold dilution, concentration 20 and 5 μmol/1, respectively) was 98.9±0.56% and 100.9±1.29%, respectively. The recovery of uric acid and creatinine added to diluted urine (100-fold dilution, concentration 50 and 100 μmol/l, respectively) was 99.4±0.72% and 98.7±1.45%, respectively (mean±R.S.D., n=6).  相似文献   


14.
Gra?yna Chwatko 《Talanta》2009,79(2):229-234
Thiosulfate is a sulfate analogue with a thiosulfur substituent and is found in human samples. Its concentration in urine is increased in some diseases and after exposure to hydrogen sulfide gas. We have developed a sensitive, simple and cheap method for thiosulfate determination in urine. The method is based on precolumn derivatization with 2-chloro-1-methylquinolinium tetrafluoroborate followed by reversed-phase liquid chromatography separation and ultraviolet detection of 1-methyl-2-thioquinolone at 375 nm. The calibration curve for thiosulfate was linear in the tested range 0.5-50 μmol L−1 with correlation coefficient better than 0.999. The analytical recovery and relative standard deviation values for precision within the calibration range were from 90.1% to 104.2% and from 2.39% to 5.59%, respectively. The lower limit of detection and quantitation were 0.3 and 0.5 μmol L−1, respectively. The mean (range) concentration of thiosulfate normalized against creatinine for apparently healthy seven women and six men was 2.21 (1.45-2.77) and 2.51 (1.36-4.89) mmol mol−1 creatinine, respectively. We monitored thiosulfate in urine samples from one volunteer for 24 h. The urinary excretion of thiosulfate was 21.4 μmol per 24 h. This method can be used for routine clinical monitoring thiosulfate in urine. Cysteine and cysteinylglycine can be measured concurrently, if needed.  相似文献   

15.
For the quantitative determination of trovafloxacin (a new naphthyridinone antibacterial agent) in serum and urine a simple isocratic HPLC method with fluorimetric detection is described. Serum was deproteinised with a mixture of acetonitrile and perchloric acid. The protein-free extract was separated on a reversed-phase column (Nucleosil 100-5 C18) and quantified by means of fluorescence (excitation 275 nm, emission 405 nm). The mobile phase consisted of a mixture of 250 ml acetonitrile and 750 ml distilled water containing 10 mmol/l tetrabutylammonium phosphate. Urine was diluted with 0.25 mol/l phosphoric acid 1:20 (v/v) which was adjusted to pH 3.6 with sodium hydroxide solution. Diluted urine samples were separated on a cation-exchange column (Nucleosil 100-5 SA) and also detected by means of fluorescence. Trovafloxacin was sufficiently separated from endogenous compounds. Results of validation are given. The method was applied successfully to a study of healthy volunteers.  相似文献   

16.
Hasany SM  Saeed MM  Ahmed M 《Talanta》2001,54(1):89-98
The sorption of traces of silver ions onto polyurethane foam (PUF) has been investigated in detail. Maximum sorption of silver (K(d)=6109 cm(3) g(-1), %sorption>97.5%) has been achieved from 1 M nitric acid solution after equilibrating silver ions with approximately 29 mg PUF for 20 min. The kinetics and thermodynamics of the sorption of silver ions onto PUF have also been studied. The sorption of silver ions onto PUF follows a first-order rate equation, which results as 0.177 min(-1). The variation of sorption with temperature yields the values of DeltaH=-56.1+/-3.2 kJ mol(-1), DeltaS=-159.7+/-10.5 J mol(-1) K(-1) and DeltaG=-8.68+/-0.09 kJ mol(-1) at 298 K with a correlation factor gamma=0.9919. The sorption data were subjected to different sorption isotherms. The sorption follows Langmuir, Freundlich and Dubinin-Radushkevich (D-R) isotherms. The values of Langmuir isotherms Q=65.4+/-1.5 mumol g(-1) and b=(4.79+/-1.16)x10(4) dm(3) mol(-1) have been evaluated for Langmuir sorption constants, whereas the Freundlich sorption isotherm gives the value 1/n=0.12+/-0.02 and A=0.15+/-0.03 mmol g(-1). The D-R parameters computed were beta=-0.000817+/-0.000206 mol(2) kJ(-2), X(m)=76.8+/-8.7 mumol g(-1) and E=24.7+/-3.2 kJ mol(-1). The influence of common ions on the sorption was also examined. It is observed that Hg(II), thiourea, Al(III), thiocyanate and thiosulphate reduce the sorption, whereas Cu(II), citrate and acetate ions enhance the sorption significantly. It can be concluded that PUF may be used to remove traces of silver ions from its very dilute solutions or for its preconcentration from aqueous acidic solutions.  相似文献   

17.
The assay of malondialdehyde (MDA) is widely used in clinical chemistry laboratories to investigate lipid peroxidation in oxidative pathologies. In the present work, the thiobarbituric acid (TBA) reaction was carried out on plasma, human erythrocytes and fibroblasts. The reagents used were those of the fluorimetry MDA kit manufactured by Sobioda. We have defined the application of this kit to high-performance liquid chromatography. This adaptation satisfied the criteria of good analytical practice. The detection limit was 2.5 pmol per injection. The retention time of the MDA-TBA2 peak (4.96 +/- 0.07 min) led to excellent resolution of the complex. The within-assay (6-12%) and between-assay (11-12%) precisions were satisfactory. The analytical recovery of MDA after spiking samples of human plasma with tetraethoxypropane standards varied from 70 to 100%. The mean lipoperoxide concentration determined in 32 healthy adults (20-40 years) was 1.04 +/- 0.23 mumol l-1 in plasma. Applied to the erythrocytes of fifteen laboratory workers, the method furnished physiological values of 0.59 +/- 0.21 mumol l-1. Concentrations were significantly higher in chronic renal dialysis patients (4.15 +/- 2.35 mumol l-1. The MDA content of fibroblasts cultured in standard medium was 0.38 +/- 0.04 mumol per g of protein and increased (5.78 +/- 1.38 mumol per g of protein) if the cells were grown in an iron-enriched medium. This accurate high-performance liquid chromatographic method for detection of MDA is the first one which can be applied to plasma, red blood cells and cultured cells. This technique will prevent false positives and should make inter-laboratory comparisons possible.  相似文献   

18.
TBARS法测定胰岛素口腔喷雾剂中脂质过氧化物研究   总被引:3,自引:0,他引:3  
采用硫代巴比妥酸反应物法(ThiobarbituricAcidReactiveSubstanceAssay,TBARS)对胰岛素口腔喷雾剂(InsulinBuccalSpray,IBS)中脂质过氧化程度进行了测定,并对IBS前处理方法、稀释倍数、加热作用亦进行了探究。发现在使用丙二醛(Malondialdehyde,MDA)测试盒测量IBS中脂质过氧化物(LipidPeroxide,LPO)实验中,样品应该先用有机溶剂稀释或用含0.8%(m/V)TritonX 100的0.01mol·L-1HCl溶液破乳;而乳剂测量前以稀释10倍为宜。对不同时期的IBS制剂检测,发现在IBS的一年保质期内,其脂质过氧化程度变化不大。  相似文献   

19.
A low-capacity cation-exchange HPLC method for the determination of UV-absorbing organic cations such as amino acids, histidine dipeptides, and creatinine was developed. A commercially available reversed-phase column was dynamically coated with hexadecylsulfonate, and was successfully used for the cation-exchange separation with ethylenediammonium eluting ion at pH 2.5. The coated column was enough stable for the specific use with a completely aqueous mobile phase at low and constant pH; and the day-to-day reproducibility for retention time was 0.9-1.7% of RSD (relative standard deviation). The linear relation between concentrations and detector responses (area) by using a photodiode-array UV detection at 210 nm ranged from 0.2 to 1000 microM (sample size 50 microl) for 1-methylhistidine, 3-methylhistidine, histidine, creatinine, anserine, carnosine, and homocarnosine, and from 0.5 to 2000 microM for creatine, tyrosine, and phenylalanine, with less than 5% of RSD. The UV spectrum (190-300 nm) obtained during chromatography was very indicative for each analyte. Overall recoveries were 97-104%. The developed HPLC method in conjunction with preliminary fractionation technique could be applied to the analysis of urine of patient with metabolic disorder such as phenylketonuria.  相似文献   

20.
A method for the determination of total N-acetylcysteine and thioglycolic acid in human urine is described. Because these compounds are mainly excreted as disulfides, they are first reduced to the free thiols by treatment with tris(2-carboxyethyl)phosphine hydrochloride and then derivatized with 2-chloro-1-methylquinolinium tetrafluoroborate. Separation and quantitation of the 2-S-quinolinium derivatives of the thiols were achieved by reversed-phase ion-pair liquid chromatography with UV-detection at 355 nm. Because the method enables simultaneous determination of other endogenous urinary thiols, e.g. cysteine and cysteinylglycine, amounts of these compounds in urine were also studied. Detector responses were linear over the range covering most practical situations, with correlation coefficients for all four analytes better than 0.999. Recovery and imprecision (as RSD) were within 99.77–102.17 and 0.01–7.79%, respectively. The lower limit of detection was 0.25 μmol L−1 urine for thioglycolic acid and N-acetylcysteine, and 0.12 μmol L−1 urine for cysteine and cysteinylglycine. The method was used for analysis of urine samples from 29 healthy individuals to establish reference values for the thiols, normalized to creatinine. 3-Mercaptolactic acid, 2-mercaptopropionic acid, and mercaptoethanol were not present in the urine analyzed.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号