共查询到20条相似文献,搜索用时 78 毫秒
1.
Jun Yue Bai Liang Wang Hong Jing Wang Peng Fei Huang Yu Qing Zhao Sheng Di Fan 《Mikrochimica acta》2006,156(3-4):321-326
The electrochemical behavior of epinephrine (EP) at a mercaptoacetic acid (MAA) self-assembled monolayer modified gold electrode
was studied. The MAA/Au electrode is demonstrated to promote the electrochemical response of epinephrine by cyclic voltammetry.
The possible reaction mechanism is also discussed. The diffusion coefficient D of EP is 6.85 × 10−6 cm2 s−1. In 0.1 mol L−1 phosphate buffer (pH 7.20), a sensitive oxidation peak was observed at 0.177 V, and the peak current is proportional to the
concentration of EP in the range of 1.0 × 10−5–2.0 × 10−4 mol L−1 and 1.0 × 10−7–1.0 × 10−6 mol L−1. The detection limit is 5 × 10−8 mol L−1. The modified electrode is highly stable and can be applied to the determination of EP in practical injection samples. The
method is simple, quick, sensitive and accurate. 相似文献
2.
Determination of the effective components in traditional Chinese medicine is one of the key steps for its identification.
In this paper a novel and sensitive chemiluminescence (CL) method for the determination of rhein coupled with flow-injection
analysis (FIA) is developed. It is based on the strong sensitizing effect on the weak CL reaction between luminol and ferricyanide
in alkaline solution. Under optimal experimental conditions, the relative CL intensity is proportional to the concentration
of rhein in the range of 7.0 × 10−12–7.0 × 10−10 mol L−1 and 1.0 × 10−9–4.0 × 10−5 mol L−1, the detection limit is 1.478 × 10−13 mol L−1, and the relative standard deviation (RSD) for 9 parallel measurements of 1.408 × 10−7 mol L−1 rhein is 3.4%. The method was successfully applied to the determination of rhein in pharmaceutical preparations. The possible
mechanism of CL is also briefly discussed. 相似文献
3.
A method for the determination of trace clenbuterol is described. Multi-walled carbon nanotubes (MWCNTs)-Nafion composite
was used to modify the glassy carbon electrode (GCE). The modified electrode showed high sensitivity and good selectivity
for clenbuterol detection. It offered a linear range of 1.0 × 10−9–1.0 × 10−6 mol · L−1 with a detection limit of 5.0 × 10−10 mol · L−1 in pH = 1.2 solution. The oxidation mechanism of clenbuterol on the electrode was also investigated.
Correspondence: Xiao-Ya Hu, Department of Chemistry, Yang Zhou University, Yang Zhou, Jiang Su, P.R. China 相似文献
4.
The electrooxidative behaviour and determination of quetiapine (QTP), a dibenzothiazepine derivative and antipsychotic agent,
on a glassy carbon disc electrode was investigated using cyclic (CV), linear sweep (LSV), differential pulse (DPV) and Osteryoung
square wave voltammetry (OSWV). Fully validated DP and SW voltammetric procedures are described for the determination of QTP.
QTP in pH 3.5 acetate buffer solution presents a well-defined anodic response, studied by the proposed methods. This main
response was due to the irreversible, diffusion-controlled, one-electron and one-proton oxidation of the aliphatic nitrogen
of the piperazine ring. Under optimal conditions, a detection limit of 4.0 × 10−8 mol L−1 for DPV and 1.33 × 10−7 mol L−1 for OSWV, and a linear calibration graph in the range from 4.0 × 10−6 to 2.0 × 10−4 mol L−1 were obtained for both methods. The procedure was successfully applied to the determination of the drug in tablets, human
serum and human urine with good recoveries. The detection limits were 6.20 × 10−7 mol L−1 and 5.92 × 10−7 mol L−1 in human serum and 1.44 × 10−7 mol L−1 and 1.31 × 10−6 mol L−1 in human urine, for the DPV and OSWV method, respectively. 相似文献
5.
A novel L-cysteine film modified electrode has been fabricated by means of an electrochemical oxidation procedure, and it
was successfully applied to the electrochemical determination of acetaminophen. This method utilizes the electrooxidation
of amines to their analogous cation radicals to form a chemically stable covalent linkage between the nitrogen atom of the
amine and edge plane sites at the glassy carbon electrode surface. The electrochemical behaviour of acetaminophen at the film
electrode was investigated in 0.1 mol L−1 phosphate buffer (pH 6.20). It was found that the redox peak current of acetaminophen was enhanced greatly on the film electrode.
Linearity between the oxidation peak current and the acetaminophen concentration was obtained in the range of 1.0 × 10−4–2.0 × 10−7 mol L−1 with a detection limit of 5.0 × 10−8 mol L−1. For seven parallel detections of 1.0 × 10−5 mol L−1 acetaminophen, the relative standard deviation (RSD) was 1.46%, suggesting that the film electrode has excellent reproducibility.
Application to the determination of acetaminophen in drug tablets and human urine demonstrated that the film electrode has
good stability and high sensitivity. 相似文献
6.
Lin Cui Lifang Li Shiyun Ai Huanshun Yin Peng Ju Tao Liu 《Journal of Solid State Electrochemistry》2011,15(6):1253-1261
Guanosine-5′-monophosphate (GMP) was investigated the electrochemical behaviors based on solid-phase extractionon (SPE) at
Cu-Mg-Al hydrotalcite-like compound (HTLC) modified glass carbon electrode. Cu-Mg-Al hydrotalcite-like compound (HTLC) was
proved as a new sorbent for SPE of GMP, which showed an irreversible adsorption oxidation process on the HTLC/GCE with the
oxidation peak potential located at 1.15 V (vs. SCE) in a pH 5.0 acetate buffer solution. Influencing factors of the electrochemical
behavior of GMP on the HLTC/GCE were optimized and kinetic parameters were calculated. Under the optimal conditions, with
differential pulse voltammetry (DPV), a linear relationship was obtained between the oxidation peak current and the GMP concentration
in the range from 1.0 × 10− 6 to 8.0 × 10−4 mol L−1 with the detection limit as 5.0 × 10−7 mol L−1 (signal-to-noise ratio of 3). The modified electrode surface has very good reproducibility and stability. 相似文献
7.
Ying Xu Fei Wang Le Wang Fangyuan Zhao Baocheng Yang Baoxian Ye 《Journal of Solid State Electrochemistry》2012,16(4):1473-1480
A novel voltammetric sensor, based on single-walled carbon nanotubes (SWNT) dispersed in Nafion and modified glassy carbon
electrode (GCE), was fabricated and used to determine the trace amounts of dihydromyricetin (DMY). The electrochemical behavior
of DMY at this sensor was investigated in 0.1 mol L−1 sulfuric acid solutions + 0.1 mol L−1 NaCl by cyclic voltammetry and squarewave voltammetry. Compared with bare GCE, the electrode presented an excellent response
of DMY through an adsorption-controlled quasi-reversible process. Under the optimum conditions, the response peak currents
were linear relationship with the DMY concentrations in the range of 1.0 × 10−7–1.0 × 10−5 mol L−1 with a detection limit of 9 × 10−8 mol L−1. Based on this voltammetric sensor, a simple and sensitive electroanalytical method for DMY was proposed and applied to quantitative
determination of DMY in Ampelopsis grossedentata samples. In addition, the oxidation mechanism was proposed and discussed, which could be a reference for the pharmacological
action of DMY in clinical study. 相似文献
8.
We used a carbon paste electrode modified with multi-walled carbon nanotubes as a working electrode and studied the electrochemical
behavior of zirconium-alizarin red S complex on it. It was found that the modified electrode exhibited a significant catalytic
effect toward the reduction of free alizarin red S and the complex. The second derivative linear scan voltammograms of the
complex were recorded by a polarographic analyser from 0 to −1000 mV (vs. SCE), and it was found that the complex can be adsorbed
on the surface of the modified electrode, yielding a peak at about −470 mV, corresponding to the reduction of alizarin red
S in the complex. The linear range was found to be 2.0 × 10−11–8.0 × 10−7 mol L−1, and the detection limit was 1.0 × 10−11 mol L−1 (S/N = 3) for 3 min accumulation. The procedure was successfully applied to the determination of trace amounts of zirconium in
the ore samples.
Correspondence: Pei-Hong Deng, Department of Chemistry and Material Science, Hengyang Normal University, Hengyang Hunan 421008,
P.R. China 相似文献
9.
Qiong He Tian Gan Dongyun Zheng ShengShui Hu 《Journal of Solid State Electrochemistry》2010,14(6):1057-1064
Simple and sensitive electrochemical method for the determination of nitrite, based on a nano-alumina-modified glassy carbon
electrode (GCE), is described. Nitrite yields a well-defined oxidation peak whose potential is 0.74 V at the nano-alumina-coated
GCE in 0.1 mol L−1 phosphate buffer (pH 5.0). Compared with bare GCE, the nano-alumina-modified GCE has evident catalytic effect towards the
oxidation of nitrite, and its peak current can be significantly enhanced. Some of the experimental parameters were optimized
for the determination of nitrite. The oxidation peak current was proportional to nitrite concentration in the range of 5.0 × 10−8–1.1 × 10−3 mol L−1, and a detection limit of 1.0 × 10−8 mol L−1 was obtained. This method has been successfully used to the determination of nitrite in sausage sample. Furthermore, results
obtained by the method have been compared with spectrophotometric method. 相似文献
10.
Zhong-Xian Guo Xin-Xiang Zhang Yi Gao Yuan-Zong Li Wen-Bao Chang Yun-Xiang Ci 《Mikrochimica acta》2003,141(3-4):183-189
This study describes a continuous flow procedure for monitoring atmospheric sulfur dioxide using a planar gas permeation
denuder (GPD) and a fiber optic spectrometer. When gaseous samples are directed through a GPD which consists of a gas-permeable
membrane of poly(vinylidene) difluoride and two perspex blocks with engraved channels of mirror image, the fraction of sulfur
dioxide passing the membrane is absorbed in a flowing stream of 5.0×10−4 mol L−1 5,5′-dithiobis(2,2′-dinitrobenzoic acid) (DTNB) in 0.025 mol L−1 phosphate buffer of pH 7.0, and reacts with DTNB to yield a yellow product. This product is monitored spectrophotometrically
at 410 nm with a miniature charge-coupled device (CCD) fiber optic spectrometer. The analytical range of sulfur dioxide is
easily adjusted via the flow rate of DTNB solution, normally from 200 ppb to 94 ppm (v/v). The procedure is hardly interfered
with by coexisting metal and non-metal species, except for hydrogen sulfide in the atmosphere. The error caused by hydrogen
sulfide at a sulfur dioxide level (in ppm) of 2% is less than ±10%. With the proposed procedure, the result for a mimetic
air sample is very close to that of the ultraviolet fluorescence method.
Correspondence: College of Chemistry and Molecular Engineering, Peking University, Beijing 100871, China. e-mail: yli@chem.pku.edu.cn
Received August 12, 2002; accepted November 9, 2002 相似文献
11.
A 3-amino-5-mercapto-1,2,4-triazole (TA) self-assembled monolayer-modified gold electrode (TA SAM/Au) is characterized by
X-ray photoelectron spectroscopy, A.C. impedance, cyclic voltammetry, chronoamperometry and chronocoulometry. The TA SAM/Au
exhibited good promotion of the electrochemical oxidation of dopamine. Some electrochemical parameters of dopamine such as
electron transfer number, exchange current density, standard heterogeneous rate constant, diffusion coefficient, etc., were
measured by different electrochemical methods. The peak currents of dopamine were linearly dependent on its concentration
in the range of 1.5 × 10−6–1.0 × 10−4 mol L−1, with a detection limit of 5.0 × 10−7 mol L−1. The oxidative peak potentials of dopamine and ascorbic acid were well separated at about 190 ± 10 mV in pH 2.0 BR buffers
at TA SAM/Au, the oxidation peak current increases approximately linearly with increasing concentration of both dopamine and
ascorbic acid in the concentration range of 9.98 × 10−6–4.54 × 10−4 mol L−1. It can be used for simultaneous determination of dopamine and ascorbic acid. 相似文献
12.
Single-wall carbon nanotubes (SWNT) were dispersed into water in the presence of dicetyl phosphate (DCP), and then a SWNT-DCP
film-coated glassy carbon electrode (GCE) was constructed. The electrochemical behavior of acetaminophen at bare GCE and SWNT-DCP
modified GCE were compared, suggesting that the SWNT-DCP-modified GCE significantly enhances the oxidation peak current of
acetaminophen. A sensitive and simple electrochemical method with a good linear relationship in the range of 1.0 × 10−7–2.0 × 10−5 mol L−1, was developed for the determination of acetaminophen. The detection limit is 4.0 × 10−8 mol L−1 for 3-min accumulation. This method was successfully demonstrated with tablets. 相似文献
13.
Shafiquzzaman Siddiquee Nor Azah Yusof Abu Bakar Salleh Soon Guan Tan Fatimah Abu Bakar 《Journal of Solid State Electrochemistry》2012,16(1):273-282
Electrochemical DNA biosensor was successfully developed by depositing the ionic liquid (e.g., 1-ethyl-3-methylimidazolium
trifluoromethanesulfonate ([EMIM][Otf])), ZnO nanoparticles, and chitosan (CHIT) nanocomposite membrane on a modified gold
electrode (AuE). The electrochemical properties of the [EMIM][Otf]/ZnO/CHIT/AuE for detection of DNA hybridization were studied.
Under optimal conditions using cyclic voltammetry, the target DNA sequences could be detected in the concentration range of
1.0 × 10−18 to 1.82 × 10−4 mol L−1, and with the detection limit of 1.0 × 10−19 mol L−1. This DNA biosensor detection approaches provide a quick, sensitive, and convenient method to be used in the identification
of Trichoderma harzianum. 相似文献
14.
A rapid, highly sensitive and selective fluorogenic method for the determination of traces of nitrite is described. It is
based on the reaction of weakly fluorescent 1,3,5,7-tetramethyl-8-(3,4-diaminophenyl)-difluoroboradiaza-s-indacence (DAMBO) and nitrite in acidic aqueous solution to give 1,3,5,7-tetramethyl-8-(5-benzotriazolyl)-difluoroboradiaza-s-indacene (DAMBO-T), which is highly fluorescent. The optimum reaction conditions and other analytical parameters are investigated
to enhance the sensitivity of the method. The fluorescence enhancement at 507 nm is linearly related to the concentration
of nitrite in the range of 6.0 × 10−9–5.0 × 10−7 mol L−1 with a correlation coefficient of R = 0.9995 (n = 10) and a detection limit of 1.0 × 10−10 mol L−1. The R.S.D. is 1.12% (n = 10). The method is applied to the determination of nitrite in human saliva samples with the recoveries of 96. 24–105.30%.
Correspondence: Ke-Jing Huang, Department of Chemistry, Wuhan University, Wuhan 430072, P.R. China 相似文献
15.
Xiaoying Liu Yonghong Li Xinsheng Liu Xiandong Zeng Bo Kong Shenglian Luo Wanzhi Wei 《Journal of Solid State Electrochemistry》2012,16(3):883-889
A simple sensor based on bare carbon ionic liquid electrode was fabricated for simultaneous determination of dihydroxybenzene
isomers in 0.1 mol L−1 phosphate buffer solution (pH 6.0). The oxidation peak potential of hydroquinone was about 0.136 V, catechol was about 0.240 V,
and resorcinol 0.632 V by differential pulse voltammetric measurements, which indicated that the dihydroxybenzene isomers
could be separated absolutely. The sensor showed wide linear behaviors in the range of 5.0 × 10−7–2.0 × 10−4 mol L−1 for hydroquinone and catechol, 3.5 × 10−6–1.535 × 10−4 mol L−1 for resorcinol, respectively. And the detection limits of the three dihydroxybenzene isomers were 5.0 × 10−8, 2.0 × 10−7, 5.0 × 10−7 mol L−1, respectively (S/N = 3). The proposed method could be applied to the determination of dihydroxybenzene isomers in artificial wastewater and
the recovery was from 93.9% to 104.6%. 相似文献
16.
A self-assembled electrode with a meso-2,3-dimercaptosuccinic acid (DMSA) monolayer has been characterized by electrochemical
quartz crystal microbalance and complex impedance analysis, surface enhanced Raman spectroscopy and cyclic voltammetry. The
self-assembled electrode was used for the simultaneous electrochemical detection of epinephrine (EP) and uric acid (UA) in
phosphate buffer of pH 7.7. The simultaneous oxidation of EP and UA was performed by cyclic voltammetry (CV) and differential
pulse voltammetry (DPV), and the signals for each method were well separated with a potential difference of over 330 mV and
without interference by each other. The detection limit of EP is 5.4 × 10−8 mol L−1 by CV and 5.3 × 10−8 mol L−1 by DPV and that of UA is 8.4 × 10−8 mol L−1 by CV and 4.2 × 10−8 mol L−1 by DPV. The DMSA self-assembled electrode can be applied to the simultaneous determination of EP and UA. 相似文献
17.
An ensemble of carbon fibers ultra-microelectrode modified with carbon nanotubes (EUME-CNTS) has been constructed based on
a thin carbon nanotubes film which was coated onto surfaces of carbon fibers of ultra-microelectrode. SEM micrographs illustrated
the image of carbon nanotubes on the carbon fiber surface. The electrochemical characteristics of the EUME-CNTS has been investigated
by cyclic voltammetry. The electrochemical properties of dopamine on this electrode were also studied, and the detection limit
was found to be 2.0 × 10−9 mol·L−1. Linear calibration plots were obtained for the oxidation peak current in a range 1.0 × 10−7–8.0 × 10−5 mol·L−1.
Correspondence: Xiuhua Liu, Kuaizhi Liu, Department of Chemistry and Chemical Engineering, Henan University, Henan Kaifeng
475001, P.R. China 相似文献
18.
The electrode characteristics and selectivities of PVC-based thiocyanate selective polymeric membrane electrode (PME) incorporating
the newly synthesized zinc complex of 6,7:14,15-Bzo2-10,11-(4-methylbenzene)-[15]-6,8,12,14-tetraene-9,12-N2-1,5-O2 (I
1
) and zinc complex of 6,7:14,15-Bzo2-10,11-(4-methylbenzene)-[15]-6,14-diene-9,12-dimethylacrylate-9,12-N2-1,5-O2 (I
2
) are reported here. The best response was observed with the membrane having a composition of I2:PVC:o-NPOE:HTAB in the ratio of 6:33:59:2 (w/w; milligram). This electrode exhibited Nernstian slope for thiocyanate ions over working concentration range of 4.4 × 10−7 to 1.0 × 10−2 mol L−1 with detection limit of 2.2 × 10−7 mol L−1. The performance of this electrode was compared with coated graphite electrode (CGE), which showed better response characteristics
w.r.t Nernstian slope 59.0 ± 0.2 mV decade−1 activity, wide concentration range of 8.9 × 10−8 to 1.0 × 10−2 mol L−1 and detection limit of 6.7 × 10−8 mol L−1. The response time for CGE and PME was found to be 8 and 10 s, respectively. The proposed electrode (CGE) was successfully
applied to direct determination of thiocyanate in biological and environmental samples and also as indicator electrode in
potentiometric titration of SCN− ion. 相似文献
19.
A voltammetric sensor for the determination of parathion has been developed based on the use of a poly(carmine) film electrode.
The reduction of parathion at the poly(carmine) modified glassy carbon electrode (GCE) is studied by cyclic voltammetry (CV)
and linear scan voltammetry (LSV). Parathion yields a well-defined reduction peak at a potential of −0.595 V on the poly(carmine)
modified GCE in pH 6.0 phosphate buffer solution (PBS). Compared with that on a bare GCE, the reduction peak current of parathion
is significantly enhanced. All the experimental parameters are optimized for the determination of parathion. The reduction
peak current is linear with the parathion concentration in the range of 5.0 × 10−8 to 1.0 × 10−5 mol L−1, and the detection limit is 1.0 × 10−8 mol L−1. 相似文献
20.
Sensitive fluorescent probes for determination of hydrogen peroxide and glucose based on enzyme-immobilized magnetite/silica nanoparticles 总被引:2,自引:0,他引:2
Qing Chang Lihua Zhu Guodong Jiang Heqing Tang 《Analytical and bioanalytical chemistry》2009,395(7):2377-2385
Sensitive fluorescent probes for the determination of hydrogen peroxide and glucose were developed by immobilizing enzyme
horseradish peroxidase (HRP) on Fe3O4/SiO2 magnetic core–shell nanoparticles in the presence of glutaraldehyde. Besides its excellent catalytic activity, the immobilized
enzyme could be easily and completely recovered by a magnetic separation, and the recovered HRP-immobilized Fe3O4/SiO2 nanoparticles were able to be used repeatedly as catalysts without deactivation. The HRP-immobilized nanoparticles were able
to activate hydrogen peroxide (H2O2), which oxidized non-fluorescent 3-(4-hydroxyphenyl)propionic acid to a fluorescent product with an emission maximum at 409 nm.
Under optimized conditions, a linear calibration curve was obtained over the H2O2 concentrations ranging from 5.0 × 10−9 to 1.0 × 10−5 mol L−1, with a detection limit of 2.1 × 10−9 mol L−1. By simultaneously using glucose oxidase and HRP-immobilized Fe3O4/SiO2 nanoparticles, a sensitive and selective analytical method for the glucose detection was established. The fluorescence intensity
of the product responded well linearly to glucose concentration in the range from 5.0 × 10−8 to 5.0 × 10−5 mol L−1 with a detection limit of 1.8 × 10−8 mol L−1. The proposed method was successfully applied for the determination of glucose in human serum sample. 相似文献